CITY OF LOS ANGELES CALIFORNIA

Similar documents
CALIFORNIA ERIC GARCETTI MAYOR

CITY OF LOS ANGELES CALIFORNIA

CITY OF LOS ANGELES CALIFORNIA

SECTION SEISMIC CONTROL OSHPD

Fig. 1 - Standard Clevis Hanger

Fig Beam Clamp Retaining Strap (B-Line B3367)

Large cable sizes stronger than pipe/strut

KINETICS Pipe & Duct Seismic Application Manual

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available.

TOLCO Fire Protection Support Systems. Pipe Hangers Supports Seismic Bracing. UL Listed FM Approved for Fire Sprinkler Installations

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

KINETICS Pipe & Duct Seismic Application Manual

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

Seismic Installation Manual

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available.

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

REV. 9/08. Mounting Structure PRE-INSTALLATION GUIDE for Ergon Skybooms

KINETICS Pipe & Duct Seismic Application Manual

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS. 1. Hangers and supports for electrical equipment and systems.

Cantilevered Rail System

SECTION CHAIN-LINK FENCES AND GATES 02821/1

MECHANICAL AND PLUMBING SUPPORTS. To order online vist us at.

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

REPORT HOLDER: MITEK USA, INC. (FORMERLY USP STRUCTURAL CONNECTORS) SOUTHCROSS DRIVE, SUITE 200 BURNSVILLE, MINNESOTA EVALUATION SUBJECT:

Technical Services Information Bureau

Suspension Systems for Acoustical Lay-in Ceilings Seismic Design Categories D, E & F

MERCHANTS METALS. A. ASTM F552 Standard Terminology Relating to Chain Link Fencing

DDI + (DECK INSERT) Threaded Insert for Metal Deck

Open-Web Trusses. Including Red-L, Red-W, Red-S, Red-M and Red-H Trusses. Design Flexibility. Outstanding Strength-to-Weight Performance

B-LINE SERIES. DURA-BLOK rooftop supports BRTS-17 DURA-BLOK. A complete rooftop support solution

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

ITEM 686 TRAFFIC SIGNAL POLE ASSEMBLIES (STEEL)

Suspension System Data Center Ceiling Solutions

EVALUATION REPORT. PFC-5551 Reissued April 1, Filing Category: DESIGN Steel (038)

WIND SPEED AND DESIGN CRITERIA FOR FLEXIBLE FACE SIGNS CONSTRUCTED OF ABC EXTRUSIONS

Materials Carbon Steel and Malleable Iron are used in the manufacture of concrete inserts. Stainless Steel and other materials are available.

REPORT HOLDER: BLUE POINT FASTENING, INC YORBA COURT CHINO, CALIFORNIA EVALUATION SUBJECT:

REPORT HOLDER: FASTENING SPECIALISTS, INC. 726 CENTRAL FLORIDA PARKWAY ORLANDO, FLORIDA EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

UNIFIED FACILITIES GUIDE SPECIFICATIONS

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

Smarter. Safer. Leaner.

CANTILEVER RACK SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

PATHWAYS FOR COMMUNICATIONS SYSTEMS

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

SECTION MASONRY ACCESSORIES

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

FROM: PROPOSED SUBSTITUTION: Use HILTI X-CW Ceiling Wire for Suspended Ceiling Systems

Originally Issued: 02/11/2011 Revised: 02/23/2018 Valid Through: 02/28/2019

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA TOWSON, MARYLAND EVALUATION SUBJECT:

Anvil CSI 3 Part MasterFormat Specifications:

ACCEPTANCE CRITERIA FOR HELICAL PILE SYSTEMS AND DEVICES PREFACE

SAMPLE TC6K Elevator Design Summary. Order No PO-47201

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: EPIC METALS CORPORATION 11 TALBOT AVENUE RANKIN, PENNSYLVANIA 15104

Superstrut. Metal Framing. Pipe Straps, Pipe Clamps and Hangers

A. Product Data shall be provided for each type of product indicated.

Tables with Allowable ASD Seismic Values For Design at R = 6.5. Special Moment Frame MF1-12

SJI Code of Standard Practice

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

Contents DESIGNER S STRUCTURAL PRODUCTS GUIDE. Tegral Purlins & Rails

SECTION PLATE CONNECTED WOOD TRUSSES

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

Originally Issued: 03/08/2013 Revised: 03/14/2017 Valid Through: 03/31/2019

DIVISION: EARTHWORK SECTION: BORED PILES REPORT HOLDER: HELICAL ANCHORS, INC BOONE AVENUE, NORTH MINNEAPOLIS, MINNESOTA 55428

HANDSET WALL FORM. Handset Wall Form. Quick Assembly - can be built using only a hammer. Reduced weight increases productivity

SECTION VIBRATION ISOLATION FOR PLUMBING PIPING AND EQUIPMENT

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

Quick Tie System (QTS) TER No

REPORT HOLDER: MITEK USA, INC. (FORMERLY USP STRUCTURAL CONNECTORS) SOUTHCROSS DRIVE, SUITE 200 BURNSVILLE, MINNESOTA EVALUATION SUBJECT:

EXCEL MODULAR STANDARD SCAFFOLD COMPONENT TECHNICAL MANUAL

CHAIN LINK FENCES AND GATES

D D TYPE A1, A2 & B MICHIGAN DEPARTMENT OF TRANSPORTATION 5-40 CONNECTION. L4" x 4" x 3/8" Brace. C8 x 4.25 Strut. WT9 x 17.5.

Specifications Electrical Metallic Tubing (EMT)

ATI Evaluation Service A Division of Architectural Testing Certification Services

SECTION 1043 FENCE MATERIAL

DIVISION: EARTHWORK SECTION: BORED PILES REPORT HOLDER: MAGNUM PIERING, INC. 156 CIRCLE FREEWAY DRIVE CINCINNATI, OHIO 45246

Originally Issued: 05/20/2013 Revised: 07/07/2017 Valid Through: 05/31/ Design

SECTION I -- IRONWORK

Houston Community College 3200 Main Parking Garage November 15, 2010 Houston Community College

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: EARTHWORK SECTION: BORED PILES REPORT HOLDER: GEOTECH ENTERPRISES, INC.

4Dimension strut & accessories

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

GroundTrac. Installation Manual

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

Lateral Design of Mid- Rise Wood Structures

Code Compliance Research Report CCRR-0194

ACCEPTANCE CRITERIA FOR HELICAL FOUNDATION SYSTEMS AND DEVICES PREFACE

Supplemental Concrete Tilt Up Retrofit Plan Check Correction Sheet (2014 LABC)

Wall Mounted Jib Crane

DIVISION: CONCRETE SECTION: CAST IN CONCRETE ANCHORS SECTION: CONCRETE ANCHORS REPORT HOLDER: MASON WEST, INC.

CURTAINWALL DEFLECTION SOLUTIONS

RESIDENTIAL WOOD DECK CONSTRUCTION GUIDE

SEISMIC CEILING SUSPENSION

SHEAR BRACE. Featuring ilevel Shear Braces for Engineered and Prescriptive Applications iLevel8 (

HIGH MAST CAMERA POLE ASSEMBLY GENERAL

High Strength Epoxy Tested in Accordance with ICC-ES AC308

Transcription:

BOARD OF BUILDING AND SAFETY COMMISSIONERS VAN AMBATIELOS PRESIDENT E. FELICIA BRANNON VICE PRESIDENT JOSELYN GEAGA-ROSENTHAL GEORGE HOVAGUIMIAN JAVIER NUNEZ CITY OF LOS ANGELES CALIFORNIA ERIC GARCETTI MAYOR DEPARTMENT OF BUILDING AND SAFETY 201 NORTH FIGUEROA STREET LOS ANGELES, CA 90012 FRANK M. BUSH GENERAL MANAGER SUPERINTENDENT OF BUILDING OSAMA YOUNAN, P.E. EXECUTIVE OFFICER Jobsite Supply Co. RESEARCH REPORT: RR 26090 4720 Mission Gorge Place (CSI # 13080) San Diego, CA 92120 Attn: Brad Lawhorn REEVALUATION DUE (714) 929-8668 DATE: May 1, 2018 Issued Date: December 1, 2017 Code: 2017 LABC GENERAL APPROVAL Technical Modification Badger Industries Seismic and Components DETAILS The Badger Industries seismic SSC, SSC-HD and SSC-RF components are composed of ASTM A1011 CS, Grade 33 or equivalent minimum 33,000 psi yield strength carbon steel. Pivot pin is composed of (1/2") diameter ASTM A307 or equivalent carbon steel. A slotted tabbed washer sized to fit connection is provided with, and is required to be installed with each Badger Industries SSC-RF seismic bracket. Seismic brackets can be used for upper or lower brace end connections. Badger SBEMT pivot arm shall be removed when connecting cable brace member to pivot pin. The Allowable and (LRFD) capacities are listed in Attachments 1, 2 and 3. The Badger Industries seismic SB1258 and SBRF components are composed of ASTM A1011 CS, Grade 33 or equivalent minimum 33,000 psi yield strength carbon steel. Pivot pin is composed of (3/8") diameter ASTM A307 or equivalent carbon steel. Two slotted washers sized to fit connection is provided with, and is required to be installed with each SBRF seismic bracket. Seismic brackets can be used for upper or lower brace end connections. Badger SBEMT pivot arm shall be removed when connecting cable brace member to pivot pin. The Allowable and (LRFD) capacities are listed in Attachments 4 and 5. The Badger Industries seismic SBEMT rigid bracing component using (2)-(1/4"x1") hex washer head screws. SBEMT component is composed of minimum 33,000 psi yield strength carbon steel. The Allowable and (LRFD) capacities are listed in Attachment 6. RR 26090 Page 1 of 4 LADBS G-5 (Rev.11/23/2016) AN EQUAL EMPLOYMENT OPPORTUNITY - AFFIRMATIVE ACTION EMPLOYER

Badger Industries RE: Badger Seismic Bracing And Components The Badger Industries seismic SWB component is composed of 0.30-inch diameter, minimum 33,000 psi yield strength carbon steel rod. The Allowable and (LRFD) capacities are listed in Attachment 7. The Badger Industries seismic SCC-1 cable braces are composed of (1/16") diameter 7x7 galvanized steel aircraft cable with a stake-eye fitting at one end and a Badger Industries SCC-1 cable clamp bolt turn back connection at the other end. Badger Industries seismic SCC-2 cable braces are composed of (1/8") diameter 7x7 galvanized steel aircraft cable, or (3/16") diameter 7x19 galvanized steel aircraft cable with a stake-eye fitting at one end and a Badger Industries SCC-2 cable clamp bolt turn back connection at the other end. The Allowable and (LRFD) capacities are listed in Attachment 8. The Badger Industries seismic MDH3812, MDH1258 and MDH5834 components are composed of a minimum 33,000 psi yield strength carbon steel body. MDH3812 is composed of (1/2") diameter ASTM A307 or equivalent carbon steel shaft, and the MDH1258, and the MDH5834 is composed of (3/4") diameter ASTM A307 or equivalent carbon steel shaft. The Allowable and (LRFD) capacities are listed in Attachment 9. The Badger Industries MDH3812 with 12 gauge ASTM A641 wire tied through the 3/8-16 hole in the body of the MDH3812. The Allowable and (LRFD) capacities are listed in Attachment 10. The Badger Industries beam clamp SBC158 and SBC158L components are composed of ASTM A1011 CS, Grade 33 or equivalent minimum 33,000 psi yield strength carbon steel and a 1/2-13 ASTM A307 or equivalent carbon steel clamp bolt. The SBC158 and SBC158L beam clamps can be used as individual beam clamps or in pairs as double beam clamps. The Allowable and (LRFD) capacities are listed in Attachments 11, 12, 13, 14, 15 and 16. Note, attachments 12 and 15 reference detail (CMN) Cantilevered Member Notice, see Attachment 17. The Badger Industries seismic SHCA components are composed of ASTM A1011 CS, Grade 33 or equivalent minimum 33,000 psi yield strength carbon steel. V-Bolt is composed of (1/4") diameter ASTM A307 or equivalent carbon steel. The Allowable and (LRFD) capacities are listed in Attachment 18. The Badger Industries with Anvil International LLC seismic FIG: 212 component sizes (1-1/2" and smaller) are composed of ASTM A1011 carbon steel. FIG: 212 component sizes (2" thru 4") and FIG: 212FP component sizes (5" thru 12") are composed of ASTM A36 carbon steel. Clamp Bolts are composed of (1/2") diameter ASTM A307 or equivalent carbon steel. Badger SBEMT pivot arm shall be removed when connecting cable brace member to clamp bolt. The Allowable and (LRFD) capacities are listed in Attachments 19, 20, 21 and 22. RR 26090 Page 2 of 4 LADBS G-5 (Rev.11/23/2016) AN EQUAL EMPLOYMENT OPPORTUNITY - AFFIRMATIVE ACTION EMPLOYER

Badger Industries RE: Badger Seismic Bracing And Components The approval is subject to the following conditions: 1. This approval is limited to mechanical, electrical, ductwork, equipment, plumbing components, and fire protection components 2. Fire protection vertical hangers shall be per 2016 NFPA-13, 9.1.1.2. 3. Fire protection seismic bracing shall be per ASCE 7, Seismic Design Requirements for Non-Structural Components. 4. The use of Badger Industries components is for interior use only. 5. The tabulated allowable and/or (LRFD) loads shall not be increased for duration of loading. 6. The values listed in attachments 1-22 are for the Badger Industries components only. Calculations demonstrating the applied loads are less than the loads for each individual component within the assembly shall be submitted for plan check at the time of permit application. 7. The Badger Industries seismic components and assembly installations shall be in accordance with the manufacturer s most current instructions and the requirements herein. A copy of this report and the installation instruction shall be provided at each job site by the installing contractor. 8. Periodic Special Inspection required during installation and anchorage of piping and ductwork designed to carry hazardous material in structures in accordance with LABC 1705.11.6 DISCUSSION The technical modification is to add the SSC-HD, SB1258, SBRF, Brace Member, SWB, Cable Brace Member, MDH3812, SBC158, SBC158L, CMN, SHCA, Anvil 212, and Anvil 212FP components to the approval. This report is in compliance with the 2017 City of Los Angeles Building Code. This approval is based on load tests provided by CEL Consulting and FM Approvals. RR 26090 Page 3 of 4 LADBS G-5 (Rev.11/23/2016) AN EQUAL EMPLOYMENT OPPORTUNITY - AFFIRMATIVE ACTION EMPLOYER

Badger Industries RE: Badger Seismic Bracing And Components Addressee to whom this Research Report is issued is responsible for providing copies of it, complete with any attachments indicated, to architects, engineers and builders using items approved herein in design or construction which must be approved by Department of Building and Safety Engineers and Inspectors. This general approval of an equivalent alternate to the Code is only valid where an engineer and/or inspector of this Department has determined that all conditions of this Approval have been met in the project in which it is to be used. QUAN NGHIEM, Chief Engineering Research Section 201 N. Figueroa St., Room 880 Los Angeles, CA 90012 Phone - 213-202-9816 Fax - 213-202-9943 Attachments: Badger Industries Details (22 Pages) DE RR26090 R11/20/17 TLB1700395 1705.11.6, 2210, 2210A RR 26090 Page 4 of 4 LADBS G-5 (Rev.11/23/2016) AN EQUAL EMPLOYMENT OPPORTUNITY - AFFIRMATIVE ACTION EMPLOYER

Attachment 1 - Part SSC Badger SSC Per Chart SBEMT Pivot Arm Capacity of bracket based on seismic testing considering both tension and compression. To convert listed angle capacity to horizontal capacity multiply listed capacity by (sin) of the angle. Angle Allowable with Factor Of Safety = 3.0 Bracing Type 30º to 44º 45º to 60º 61º to 75º 1/2 In. 1,602 lbs. 1,602 lbs. 1,195 lbs. 5/8 In. 1,602 lbs. 1,602 lbs. 1,195 lbs. (LRFD) with Factor Of Safety = 2.0 Bracing Type 30º to 44º 45º to 60º 61º to 75º 1/2 In. 2,403 lbs. 2,403 lbs. 1,793 lbs. 5/8 In. 2,403 lbs. 2,403 lbs. 1,793 lbs.

x/x LARR 26090 Attachment 2 - Part SSC-RF Capacity of bracket based on seismic testing considering both tension and compression. To convert listed angle capacity to horizontal capacity multiply listed capacity by (sin) of the angle. Angle Per Chart SBEMT Pivot Arm x/x Per Chart Allowable with Factor Of Safety = 3.0 Bracing Type 3/8 In. 30º to 44º 45º to 60º 61º to 75º 1,451 lbs. 1,142 lbs. 889 lbs. 76º to 90º 821 lbs. Badger SSC-RF STW Washer d To Fit Conn. 1/2 In. 1,451 lbs. 1,142 lbs. 889 lbs. 821 lbs. 5/8 In. 1,451 lbs. 1,142 lbs. 889 lbs. 821 lbs. 3/4 In. 1,451 lbs. 1,142 lbs. 889 lbs. 821 lbs. (LRFD) with Factor Of Safety = 2.0 Bracing Type 30º to 44º 45º to 60º 61º to 75º 76º to 90º 3/8 In. 2,176 lbs. 1,714 lbs. 1,333 lbs. 1,232 lbs. 1/2 In. 2,176 lbs. 1,714 lbs. 1,333 lbs. 1,232 lbs. 5/8 In. 2,176 lbs. 1,714 lbs. 1,333 lbs. 1,232 lbs. 3/4 In. 2,176 lbs. 1,714 lbs. 1,333 lbs. 1,232 lbs.

Attachment 3 - Part SSC-HD Badger SSC Capacity of bracket based on seismic testing considering both tension and compression. To convert listed angle capacity to horizontal capacity multiply listed capacity by (sin) of the angle. SBEMT Pivot Arms Angle Allowable with Factor Of Safety = 3.0 Bracing Type 0º 30º to 44º 45º to 60º (2) - 1/2 In. 2,501 lbs. 2,501 lbs. 2,501 lbs. (LRFD) with Factor Of Safety = 2.0 Bracing Type 0º 30º to 44º 45º to 60º (2) - 1/2 In. 3,752 lbs. 3,752 lbs. 3,752 lbs. (TYP.) (2") EMT Conduit Brace Member

Attachment 4 - Part NUSIG SB1258 Patent #9,777,870 1/2 SB1258 SB1258 5/8 (1/2") NUSIG Capacity of bracket based on seismic testing considering both tension and compression. To convert listed angle capacity to horizontal capacity multiply listed capacity by (sin) of the angle. SBEMT Pivot Arm Angle Allowable with Factor Of Safety = 3.0 Bracing Type 30º to 44º 45º to 60º 61º to 75º 1/2 In. 962 lbs. 629 lbs. 540 lbs. 5/8 In. 972 lbs. 30º to 44º 1,443 lbs. 1,458 lbs. 805 lbs. 45º to 60º 943 lbs. 1,208 lbs. 643 lbs. (LRFD) with Factor Of Safety = 2.0 1/2 In. 5/8 In. Bracing Type 61º to 75º 811 lbs. 965 lbs. 1/2 SBEMT Pivot Arm SB1258 Angle NUSIG SB1258 5/8 (5/8")

Attachment 5 - Part NUSIG SBRF Patent #9,777,870 Capacity of bracket based on seismic testing considering both tension and compression. To convert listed angle capacity to horizontal capacity multiply listed capacity by (sin) of the angle. 1/2 In. Allowable with Factor Of Safety = 3.0 Bracing Type 3/8 In. 30º to 44º 688 lbs. 45º to 60º 695 lbs. 61º to 75º 688 lbs. 695 lbs. 455 lbs. 455 lbs. SBEMT Pivot Arm 76º to 90º 375 lbs. 375 lbs. Angle NUSIG SBRF SBRF NUSIG SRWxx Per Chart Upper SRW Washers And Lower SRW Washers d To Fit Conn. 5/8 In. 688 lbs. 695 lbs. 455 lbs. 375 lbs. (LRFD) with Factor Of Safety = 2.0 Bracing Type 30º to 44º 45º to 60º 61º to 75º 76º to 90º 3/8 In. 1,033 lbs. 1,043 lbs. 682 lbs. 535 lbs. 1/2 In. 1,033 lbs. 1,043 lbs. 682 lbs. 535 lbs. 5/8 In. 1,033 lbs. 1,043 lbs. 682 lbs. 535 lbs.

Attachment 6 - Brace Member Badger Industries (SBEMT) Pivot Arm (TYP.) Brace Member Length Per Note Member Shall Extend A Minimum (3/8") Beyond End Screw (TYP.) Brace Member Per Note Brace Member Per Note Min. 0º Max. 90º Brace Angle Measured From Vert (2)-(1/4" x 1") ITW Buildex Part #1149000, Or Equal Hex Washer Head Screws, (TYP.) 0º Offset 90º Offset Capacity based on seismic testing considering both tension and compression. To convert chart listed angle capacity to horizontal capacity multiply listed capacity by (sin) of the angle. Capacities listed within the chart on this sheet do not account for brace length compression capacity. Thus, calculations demonstrating the applied design demand loads are less than the brace member length compression capacity shall be submitted for plan check. Brace member shall be EMT Conduit sizes (3/4" thru 2-1/2"). Conduit shall be steel tubing constructed to UL-797 Or ANSI C-80.3. Schedule 5 or schedule 7 steel pipe with an equal or larger nominal size, and a minimum yield strength of 30,000 psi can be used in place of conduit. Brace member shall be installed as a straight, piece continuous member. Screws shall not be installed into brace member weld seam. 12 gauge strut or 90º angle can be used in place of conduit. Allowable with Factor Of Safety = 3.0 (LRFD) with Factor Of Safety = 2.0 EMTConduit Nominal 0º to 90º EMTConduit Nominal 0º to 90º 3/4 in. 618 lbs. 3/4 in. 927 lbs. 1 in. 973 lbs. 1 in. 1,459 lbs. 1-1/4 in. 1,305 lbs. 1-1/4 in. 1,958 lbs. 1-1/2 in. 1,177 lbs. 1-1/2 in. 1,765 lbs. 2 in. 1,118 lbs. 2 in. 1,677 lbs. 2-1/2 in. 1,119 lbs. 2-1/2 in. 1,678 lbs.

Attachment 7 - Part SWB Patent Pending Fits (3/8") & (1/2") Threaded Rod, Bolt, Anchor, Etc. Allowable with Factor Of Safety = 3.0 3/8 In. Bracing Type Tension Capacity of bracket based on testing considering tension only. To convert listed angle capacity to horizontal capacity multiply listed capacity by (sin) of the angle. Elev. View Angle 30º to 60º 472 lbs. Badger SWB End Fits (3/8") Plan View End Fits (1/2") 1/2 In. Tension 522 lbs. (LRFD) with Factor Of Safety = 2.0 3/8 In. 1/2 In. Bracing Type Tension Tension 30º to 60º 708 lbs. 783 lbs.

Attachment 8 - Cable Brace Member B1 Badger Pre-Assembled Stake-Eye End Live Length 307 (SCC-1) Inspection Head Stamp Capacity of cable assembly based on seismic testing considering tension. Cable ends to be connected to Badger Industries COLA listed components. To convert listed angle capacity to horizontal capacity multiply listed capacity by (sin) of the angle. Badger Industries (SCC-x) Cable Clamp Seismic Hardware Part Number SCC-1 SCC-1 SCC-2 SCC-2 Badger Industries (SCC-x) Cable Clamp Seismic Hardware Part Number SCC-1 SCC-1 SCC-2 SCC-2 Cable Brace Member, Construction Strands / Arrangement, And Material Min. (1/16") Inch Dia. (7x7) Galvanized Steel Min. (1/16") Inch Dia. (7x7) Galvanized Steel Min. (1/8") Inch Dia. (7x7) Galvanized Steel Cable Brace Member, Construction Strands / Arrangement, And Material Min. (1/16") Inch Dia. (7x7) Galvanized Steel Min. (1/16") Inch Dia. (7x7) Galvanized Steel Min. (1/8") Inch Dia. (7x7) Galvanized Steel 10 ft. lbs. 10 ft. lbs. Angle Allowable with Factor Of Safety = 3.0 Badger Industries (SCC-x) Cable Clamp Installation Torque Badger Industries (SCC-x) Cable Clamp Installation Torque (X) 1-1/2" Inch 10 ft. lbs. 1-1/2" Inch 20 ft. lbs. 1-1/2" Inch (LRFD) with Factor Of Safety = 2.0 (X) 1-1/2" Inch 10 ft. lbs. 1-1/2" Inch 20 ft. lbs. 1-1/2" Inch Cable Brace Member Live Length 10 Feet Cable Brace Member Live Length 10 Feet Badger (SCC-1) Or (SCC-2) 0º to 90º 107 lbs. 20 Feet 60 lbs. 20 Feet 209 lbs. Min. (3/16") Inch Dia. 30 ft. lbs. 1-1/2" Inch 10 Feet (7x19) Galvanized Steel 513 lbs. 0º to 90º 161 lbs. 20 Feet 90 lbs. 20 Feet 314 lbs. Min. (3/16") Inch Dia. 30 ft. lbs. 1-1/2" Inch 10 Feet (7x19) Galvanized Steel 769 lbs. Min. (3") (TYP.) Badger (SSC-x) Washer Faced Slotted Hex Bolt Washer Face Hex Nut B.I. SCC-2 A-307 (SCC-2) Inspection Head Stamp (X) Per Chart

Attachment 9 - Part MDH3812 Patent #9,850,659 255 lbs Allowable with Factor Of Safety = 3 382 lbs (LRFD) with Factor Of Safety = 2 Capacity Of MDH3812 based on seismic testing considering both tension and compression. - Part MDH1258 & MDH5834 Patent #9,850,659 537 lbs Allowable with Factor Of Safety = 3 806 lbs (LRFD) with Factor Of Safety = 2 Capacity Of MDH1258 based on seismic testing considering both tension and compression.

Attachment 10 - Part MDH3812 Patent #9,850,659 177 lbs Allowable with Factor Of Safety = 3 266 lbs (LRFD) with Factor Of Safety = 2 Capacity Of MDH3812 based on testing considering tension only. 12 Gauge ASTM A641 Wire By Others. Installed Through 3/8" Hole In [MDH3812] With Loop Return Tight To Outside Of [MDH3812] Body - Part MDH3812 Patent #9,850,659 130 lbs Allowable with Factor Of Safety = 3 196 lbs (LRFD) with Factor Of Safety = 2 Capacity Of MDH3812 based on testing considering tension only. Horiz 12 Gauge ASTM A641 Wire By Others. Installed Through 3/8" Hole In [MDH3812] With Loop Return Tight To Outside Of [MDH3812] Body 45º- 85º From Vert 05º- 45º From Horiz

Attachment 11 - Part SBC158 Patent Pending Retaining Strap Capacity of beam clamp based on testing considering tension only. Allowable with Factor Of Safety = 3.0 Threaded Rod s "W", "M", "HP" & "L" Section Steel Beams And Joists By Others Badger SBC158 3/8", 1/2" & 5/8" 2,581 lbs. (LRFD) with Factor Of Safety = 2.0 Threaded Rod s 3/8", 1/2" & 5/8" 3,872 lbs. Upper Strut Nut d To Fit Threaded Rod, (TYP.) By Others Threaded Rod, (TYP.) By Others Badger SBC158 Retaining Strap Torque-Off Badger Industries Beam Clamp Bolt, (TYP.)

Attachment 12 - Part SBC158 Patent Pending Capacity of beam clamp based on testing considering tension only. "W", "M", "HP" & "L" Section Steel Beams And Joists By Others Allowable See Cantilevered Member Notice Detail (CMN) Threaded Rod s 12 Ga. (1-5/8"x1-5/8") With (9/16"x1-1/8"x2"O.C.) Openings In Back Of Strut Member By Others 3/8"thru 3/4" 304 lbs. (LRFD) See Cantilevered Member Notice Detail (CMN) Badger SBC158 Retaining Strap Threaded Rod s (2") Min. 3/8"thru 3/4" 364 lbs. (1") Min. (6") For Listed Capacities. Greater Off-sets Shall Be Engineered By Others Torque-Off Badger Industries Beam Clamp Bolt, (TYP.)

Attachment 13 - Part SBC158 Patent Pending Capacity of beam clamp based on testing considering tension only. Reduce listed capacities to comply with design capacity limits, including but not limited to, strut member span length, load placement between beam clamps, threaded rod size, strut nut, etc. "W", "M", "HP" & "L" Section Steel Beams And Joists By Others Allowable with Factor Of Safety = 3.0 Threaded Rod s 3/8"thru 3/4" 2,479 lbs. (LRFD) with Factor Of Safety = 2.0 Threaded Rod s 3/8"thru 3/4" 3,719 lbs. Badger SBC158 Threaded Rod With Hex Nut, Square Strut Washer And Strut Nut, (TYP.) Manufacturer Spot Welded, Back-To-Back 12 Ga. (1-5/8"x1-5/8") Solid Back (without) Holes Or Slotted Openings Strut Member By Others By Others Torque-Off Badger Industries Beam Clamp Bolt, (TYP.) Badger SBC158

Attachment 14 - Part SBC158L Patent Pending Retaining Strap Capacity of beam clamp based on testing considering tension only. Allowable with Factor Of Safety = 3.0 Threaded Rod s "W", "M", "HP" & "L" Section Steel Beams And Joists By Others Badger SBC158L 3/8" thru 3/4" 3,247 lbs. (LRFD) with Factor Of Safety = 2.0 Threaded Rod s 3/8" thru 3/4" 4,871 lbs. Upper Strut Nut d To Fit Threaded Rod, (TYP.) By Others Threaded Rod, (TYP.) By Others Badger SBC158L Retaining Strap Torque-Off Badger Industries Beam Clamp Bolt, (TYP.)

Attachment 15 - Part SBC158L Patent Pending Capacity of beam clamp based on testing considering tension only. "W", "M", "HP" & "L" Section Steel Beams And Joists By Others Allowable See Cantilevered Member Notice Detail (CMN) Threaded Rod s 12 Ga. (1-5/8"x1-5/8") With (9/16"x1-1/8"x2"O.C.) Openings In Back Of Strut Member By Others 3/8"thru 3/4" 304 lbs. (LRFD) See Cantilevered Member Notice Detail (CMN) Badger SBC158L Retaining Strap Threaded Rod s 3/8"thru 3/4" 364 lbs. (1") Min. (6") For Listed Capacities. Greater Off-sets Shall Be Engineered By Others (2") Min. Torque-Off Badger Industries Beam Clamp Bolt, (TYP.)

Attachment 16 - Part SBC158L Patent Pending Capacity of beam clamp based on testing considering tension only. Reduce listed capacities to comply with design capacity limits, including but not limited to, strut member span length, load placement between beam clamps, threaded rod size, strut nut, etc. "W", "M", "HP" & "L" Section Steel Beams And Joists By Others Allowable with Factor Of Safety = 3.0 Threaded Rod s 3/8" thru 3/4" 3,264 lbs. (LRFD) with Factor Of Safety = 2.0 Badger SBC158L Badger SBC158L Threaded Rod s 3/8" thru 3/4" 4,896 lbs. Threaded Rod With Hex Nut, Square Strut Washer And Strut Nut, (TYP.) By Others Manufacturer Spot Welded, Back-To-Back 12 Ga. (1-5/8"x1-5/8") Solid Back (without) Holes Or Slotted Openings Strut Member By Others Torque-Off Badger Industries Beam Clamp Bolt, (TYP.)

Attachment 17 - (CMN) Cantilevered Member Notice 2º Horizontal Reference 2º Horizontal Reference Horizontal Reference 2º Notice: The depictions above demonstrate how visibly noticeable two degrees (2º) of angular deflection of a cantilevered beam may be. The greater the length of the cantilever, the greater the linear offset from horizontal will become. While such deflections may be structurally sound and within code allowance, they may be visibly concerning to those unfamiliar with the code calculations and standard beam deflection principles. As such, Badger Industries Installation Details that reference this, Cantilever Member Notice Detail (CMN), have had their listed gravity capacities reduced to represent maximum allowable loads resulting in an average of one degree (1º) of angular deflection, as derived from independent lab testing. Badger Industries believes these reductions will increase system safety factors, may prevent misalignment of the trade system, and may eliminate rod bending concerns.

Attachment 18 - Part SHCA Patent Pending 932 lbs Allowable with Factor Of Safety = 3 1,398 lbs (LRFD) with Factor Of Safety = 2 Compression capacity Of single strut vertical member at maximum length. (12 Ga.) Strut Per Detail Max. (6") Max. (1/4") Gap, (TYP.) Max. (6") a5 - a5 For (3/8") Inch Support Rod Torque Both Break-Off Hex Nuts Evenly To (3 ft lbs) Or (36 in lbs). Hex Nut Head Should Not Be Broken Off, And (3/8") Rod Should Not Be Bent Or Deformed (TYP.) Support Threaded Rod, By Others Max. (10'-0") (TYP.) (12 ga. 1-5/8"x1-5/8") Single Strut Member, By Others (1 And 2 Of 2) Badger (SHCA) Clamp Assemblies (TYP.) (12 Ga.) Strut Per Detail a5 a5 Max. (3") a5 - a5 a5 a5 Max. (3") For (1/2") Inch And Larger Support Rod s Tighten Both Break-Off Hex Nuts Evenly Until Hex Head Breaks Away Seismic Bracing Not Shown For Clarity Seismic Bracing Not Shown For Clarity Strut Trapeze Or Equipment Supported Item By Others Single Hanger Supported Item By Others

Attachment 19 - Anvil FIG: 212 & FIG: 212FP Min. 0º Max. 90º Brace Angle Measured From Vert SBEMT For At Brace Angle Multiply Listed Capacity By (Sin) Of The Angle Min. 0º Max. 90º Brace Angle Measured From Vert SBEMT For At Brace Angle Multiply Listed Capacity By (Sin) Of The Angle Nut 1 Nut 1 ANVIL (AS 3792) Cushion Strip Required For Copper Piping Nut 2 ANVIL Fig. 212 Or ANVIL Fig. 212FP Nut 2 ANVIL Fig. 212 Or ANVIL Fig. 212FP Capacity based on seismic testing considering both tension and compression. To convert listed horizontal capacity to angle capacity multiply listed capacity by (sin) of the angle. ANVIL Fig. 212 Fig. 212FP Transverse Brace - Allowable with Factor Of Safety = 3.0 Piping Or Conduit Nominal Steel Pipe, RMC Conduit 1" Fig. 212 1 in. 309 lbs. 1-1/4" Fig. 212 1-1/2" Fig. 212 2" Fig. 212 2-1/2" Fig. 212 3" Fig. 212 3-1/2" Fig. 212 4" Fig. 212 5" Fig. 212FP 6" Fig. 212FP 1-1/4 in. 1-1/2 in. 2 in. 2-1/2 in. 3 in. 3-1/2 in. 4 in. 5 in. 6 in. 386 lbs. 406 lbs. 650 lbs. 1,469 lbs. 1,469 lbs. 1,213 lbs. 1,469 lbs. 1,469 lbs. 1,469 lbs. 8" Fig. 212FP 8 in. 1,574 lbs. 10" Fig. 212FP 10 in. 1,545 lbs. 12" Fig. 212FP 12 in. 978 lbs. Cast-Iron Pipe 739 lbs. 1,165 lbs. N/A 1,008 lbs. N/A 1,265 lbs. 1,292 lbs. 1,161 lbs. 873 lbs. 900 lbs. 703 lbs. Copper Pipe 650 lbs. 400 lbs. 528 lbs. Not Tested 445 lbs. 409 lbs. 368 lbs. EMT Conduit 650 lbs. 980 lbs. 1,255 lbs. 1,213 lbs. 742 lbs. Sch 5 Steel Pipe 650 lbs. 980 lbs. 1,255 lbs. 1,213 lbs. 742 lbs.

Attachment 20 - Anvil FIG: 212 & FIG: 212FP Min. 0º Max. 90º Brace Angle Measured From Vert SBEMT For At Brace Angle Multiply Listed Capacity By (Sin) Of The Angle Min. 0º Max. 90º Brace Angle Measured From Vert SBEMT For At Brace Angle Multiply Listed Capacity By (Sin) Of The Angle Nut 1 Nut 1 ANVIL (AS 3792) Cushion Strip Required For Copper Piping Nut 2 ANVIL Fig. 212 Or ANVIL Fig. 212FP Nut 2 ANVIL Fig. 212 Or ANVIL Fig. 212FP Capacity based on seismic testing considering both tension and compression. To convert listed horizontal capacity to angle capacity multiply listed capacity by (sin) of the angle. ANVIL Fig. 212 Fig. 212FP Transverse Brace - (LRFD) with Factor Of Safety = 2.0 Piping Or Conduit Nominal Steel Pipe, RMC Conduit 1" Fig. 212 1 in. 464 lbs. 1-1/4" Fig. 212 1-1/2" Fig. 212 2" Fig. 212 2-1/2" Fig. 212 3" Fig. 212 3-1/2" Fig. 212 4" Fig. 212 5" Fig. 212FP 6" Fig. 212FP 1-1/4 in. 1-1/2 in. 2 in. 2-1/2 in. 3 in. 3-1/2 in. 4 in. 5 in. 6 in. 580 lbs. 609 lbs. 975 lbs. 2,204 lbs. 2,204 lbs. 1,820 lbs. 2,204 lbs. 2,204 lbs. 2,204 lbs. 8" Fig. 212FP 8 in. 2,361 lbs. 10" Fig. 212FP 10 in. 2,318 lbs. 12" Fig. 212FP 12 in. 1,467 lbs. Cast-Iron Pipe 1,108 lbs. 1,747 lbs. N/A 1,513 lbs. N/A 1,897 lbs. 1,938 lbs. 1,741 lbs. 1,310 lbs. 1,350 lbs. 1,055 lbs. Copper Pipe 975 lbs. 601 lbs. 792 lbs. Not Tested 667 lbs. 614 lbs. 553 lbs. EMT Conduit 975 lbs. 1,470 lbs. 1,883 lbs. 1,820 lbs. 1,114 lbs. Sch 5 Steel Pipe 975 lbs. 1,470 lbs. 1,883 lbs. 1,820 lbs. 1,114 lbs.

Attachment 21 - Anvil FIG: 212 & FIG: 212FP Min. 30º Max. 75º Brace Angle Measured From Vert For At Brace Angle Multiply Listed Capacity By (Sin) Of The Angle SBEMT ANVIL Fig. 212 Or ANVIL Fig. 212FP Capacity based on seismic testing considering both tension and compression. To convert listed horizontal capacity to angle capacity multiply listed capacity by (sin) of the angle. ANVIL Fig. 212 Fig. 212FP Longitudinal Brace - Allowable with Factor Of Safety = 3.0 Piping Or Conduit Nominal Steel Pipe, RMC Conduit 1" Fig. 212 1 in. 1-1/4" Fig. 212 1-1/2" Fig. 212 2" Fig. 212 2-1/2" Fig. 212 3" Fig. 212 3-1/2" Fig. 212 4" Fig. 212 5" Fig. 212FP 6" Fig. 212FP 1-1/4 in. 1-1/2 in. 2 in. 2-1/2 in. 3 in. 3-1/2 in. 4 in. 5 in. 6 in. 600 lbs. 734 lbs. 734 lbs. 553 lbs. 504 lbs. 734 lbs. 734 lbs. 8" Fig. 212FP 8 in. 787 lbs. 10" Fig. 212FP 10 in. 707 lbs. 12" Fig. 212FP 12 in. 489 lbs. Cast-Iron Pipe 369 lbs. 582 lbs. N/A 504 lbs. N/A 376 lbs. 550 lbs. 580 lbs. 436 lbs. 450 lbs. 351 lbs. Copper Pipe Not Tested EMT Conduit 490 lbs. 628 lbs. 553 lbs. 371 lbs. Sch 5 Steel Pipe 490 lbs. 628 lbs. 553 lbs. 371 lbs. Design and located transverse bracing at changes in direction to provided longitudinal restraint.

Attachment 22 - Anvil FIG: 212 & FIG: 212FP Min. 30º Max. 75º Brace Angle Measured From Vert For At Brace Angle Multiply Listed Capacity By (Sin) Of The Angle SBEMT ANVIL Fig. 212 Or ANVIL Fig. 212FP Capacity based on seismic testing considering both tension and compression. To convert listed horizontal capacity to angle capacity multiply listed capacity by (sin) of the angle. ANVIL Fig. 212 Fig. 212FP Longitudinal Brace - (LRFD) with Factor Of Safety = 2.0 Piping Or Conduit Nominal Steel Pipe, RMC Conduit 1" Fig. 212 1 in. 1-1/4" Fig. 212 1-1/2" Fig. 212 2" Fig. 212 2-1/2" Fig. 212 3" Fig. 212 3-1/2" Fig. 212 4" Fig. 212 5" Fig. 212FP 6" Fig. 212FP 1-1/4 in. 1-1/2 in. 2 in. 2-1/2 in. 3 in. 3-1/2 in. 4 in. 5 in. 6 in. 900 lbs. 1,102 lbs. 1,102 lbs. 829 lbs. 75 lbs. 1,102 lbs. 1,102 lbs. 8" Fig. 212FP 8 in. 1,181 lbs. 10" Fig. 212FP 10 in. 1,061 lbs. 12" Fig. 212FP 12 in. 734 lbs. Cast-Iron Pipe 554 lbs. 874 lbs. N/A 756 lbs. N/A 564 lbs. 825 lbs. 871 lbs. 655 lbs. 675 lbs. 527 lbs. Copper Pipe Not Tested EMT Conduit 735 lbs. 942 lbs. 829 lbs. 557 lbs. Sch 5 Steel Pipe 735 lbs. 942 lbs. 829 lbs. 557 lbs. Design and located transverse bracing at changes in direction to provided longitudinal restraint.

Integrated Lean Constuction Through Innovation www.badgerindustries.com www.nodrillhangers.com www.steelbeamclamps.com