Bracing Systems. Available At VIKING SA Tel: (+352) Fax: (+352)

Similar documents
TOLCO Fire Protection Support Systems. Pipe Hangers Supports Seismic Bracing. UL Listed FM Approved for Fire Sprinkler Installations

Fig. 1 - Standard Clevis Hanger

Large cable sizes stronger than pipe/strut

Fig Beam Clamp Retaining Strap (B-Line B3367)

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available.

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

Seismic Installation Manual

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

KINETICS Pipe & Duct Seismic Application Manual

SECTION SEISMIC CONTROL OSHPD

Suspension System Data Center Ceiling Solutions

KINETICS Pipe & Duct Seismic Application Manual

Model # 238HS-P8. 4/27/2011 Page 1 of 11

Series 5500 Bellows Pump Connectors Catalog 474E

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available.

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

Materials Carbon Steel and Malleable Iron are used in the manufacture of concrete inserts. Stainless Steel and other materials are available.

FORM HEADWALL. FORM HEADWALL (floating) (floating) Installation Manual

Model # 800SM-PS3. 8/3/2016 Page 1 of 8

Dexco Structural I-Beam Cantilever Racks Versatile, durable storage solutions for materials of considerable length and mass

-165 C / -265 F CRYOGENIC REBAR SPLICING SYSTEMS

ASSEMBLY INSTRUCTIONS RESIDENTIAL SOLUTION CROSSRAIL GROUND MOUNT SYSTEM USA

American Metal Specialties, Inc.

Model # 158-P4. 12/12/2013 Page 1 of 11

CADWELD Rebar Metal Filled Mechanical Splices

Model # 358H-PR. 4/8/2011 Page 1 of 12

Model # 358-R48. 7/7/2011 Page 1 of 11

Dura Rack Family Of Products. 237,000 sq. ft. manufacturing facility

HANDSET WALL FORM. Handset Wall Form. Quick Assembly - can be built using only a hammer. Reduced weight increases productivity

Protective Capony RTC-16

CANTILEVER RACK SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

MECHANICAL AND PLUMBING SUPPORTS. To order online vist us at.

RHE3 Dock Leveler Installation Manual

REV. 9/08. Mounting Structure PRE-INSTALLATION GUIDE for Ergon Skybooms

SPECIFICATION SECTION 05515: LADDERS O Keeffe s Aluminum Ladders

Installation Guide Document No Transaction Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017

PEN SEAL. Pipe Penetration Seals

Smarter. Safer. Leaner.

Drag Chain Conveyor Installation and Operation Manual

BUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466

Model # 338S-OP. 9/30/2011 Page 1 of 13

RIGID LIFELINES PRODUCT SPECIFICATIONS 1

Model # BARK-358-RDP

PV Mounting System 2703 SERIES 200 UL GROUND MOUNT SYSTEM. SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual

General Guidelines. Tools Required. Instructions for Part # SC500-AF. Safety

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

Product Specifications MRI Trench Duct

EVALUATION REPORT. PFC-5551 Reissued April 1, Filing Category: DESIGN Steel (038)

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS. 1. Hangers and supports for electrical equipment and systems.

SECTION I -- IRONWORK

REPORT HOLDER: LOOS & CO., INC. 901 INDUSTRIAL BOULEVARD NAPLES, FLORIDA EVALUATION SUBJECT:

Fire protection solutions

Fire Barrier Duct Wrap 615+

Series 1100 Mechanical Joint Restraint for Ductile Iron Pipe

WHAT IS CANTILEVER RACK?

CHAIN LINK FENCES AND GATES

7 PIECE TUBE FLARING KIT

Technical Services Information Bureau

Insulated Fire-Rated Access Door Model(s): BIT/BIW/BIP

SECTION PLATE CONNECTED WOOD TRUSSES

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

GALVA-STOP. Pallet Rack Backing Safety System

The Insert that Changed the the Anchoring Industry!

MERCHANTS METALS. A. ASTM F552 Standard Terminology Relating to Chain Link Fencing

1675 Locust Street Red Bud, IL Phone: Fax: WARRANTY & TERMS

SECTION CHAIN LINK FENCES AND GATES (GALVANIZED) A. Fence framework, fabric, gates, and accessories.

hors Anc Eaton's B-Line series fasteners 183

PERFORM WITH PRECISION BOX CULVERT TRAVELER CONCRETE CONSTRUCTION PRODUCTS APPLICATION GUIDE

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION 1043 FENCE MATERIAL

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

1675 Locust Street Red Bud, IL Phone: Fax: WARRANTY & TERMS

PATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge

B-LINE SERIES. DURA-BLOK rooftop supports BRTS-17 DURA-BLOK. A complete rooftop support solution

ROLLING RACK. Simple Security

B R OA DWAY RAC K. High Security

ROOF MOUNT KIT OWNERS MANUAL

DRYWALL DOLLY 900 LB. CAPACITY

TERWA REBAR CONNECTION COUPLERS

Canopies & Exposed Structure Areas Commercial Ceilings and Walls Solutions Guide

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

Installation Instructions

Kennedy Valve. A Division of McWane, Inc. AWWA PRODUCTS

ERICO SYSTEM ESE Lightning Protection Products

80/90/100/120/mm POST Standard Medium Heavy Extra Heavy

Model # 922-S4. 12/18/2013 Page 1 of 8

GroundTrac. Installation Manual

SHCM SHOWER COLUMN INSTALLATION INSTRUCTIONS

H 12 Heavy Duty Modern Tripod 8 Seat Swing Heavy Duty Hangers

BIN LINER INSTALLATION MANUAL IMPORTANT!

Aero Tec Models 700 & 750 (115 vac)

CURTAINWALL DEFLECTION SOLUTIONS

SECTION GYPSUM BOARD ASSEMBLIES

Basic Suspension Systems

where high efficiency is the standard

B-500 / B-600 SERIES

Good Husband Brand Remote Lighting Lifter

BoSS Climalite Camera and lighting tower

Transcription:

Bracing Systems Available At VIKING SA Tel: (+352) 58-37-37-1 Fax: (+352) 58-37-36 Email: vikinglux@vikingcorp.

Bracing Systems To help ensure the availability and operation of safety systems after an earthquake event, many building and industry codes now include requirements for the design and installation of seismic sway bracing for non-structural components, such as fire sprinkler, mechanical, electrical and plumbing systems. The innovative line of CADDY Bracing Systems was developed to help keep fire sprinkler systems intact after a seismic event and to minimize water damage resulting from leaks or ruptures. CADDY Bracing Systems provide contractors with high-quality, engineered solutions, which include rigid bracing, cable bracing and rod stiffeners. Quick and easy installation Lower total installed cost Meets requirements of NFPA 13 culus Listed FM Approved OSHPD Pre-Approved Rigid Bracing Cable Bracing Branch Line Restraint System 2 Rod Stiffeners

Rigid Bracing The CADDY line of innovative rigid bracing products was designed to provide superior performance and meet the highest seismic load requirements. The products have been designed with the end user in mind and provide contractors with labor-saving features to promote quick and easy installation. The system of products supports lateral and longitudinal bracing and offers a wide range of structural and pipe attachments. Patent-pending lateral braces eliminate need for multiple trips up and down ladders Adjustable design can be used with different brace pipe sizes, providing flexibility on the jobsite and reducing contractor inventory Snap-off bolt head helps enable easy installation and inspection of seismic sway braces culus Listed FM Approved OSHPD Pre-Approved (OPA-2629-) to the 20 California Building Code Structural Attachments for Rigid Bracing Sway Braces 3 Replacement Nuts and Bolts for Rigid Bracing

Structural Attachments for Rigid Bracing Bar Joist Attachment Adjustable I-Beam Attachment Strut Seismic Hinge Universal Structural Attachment 4 Multi Attachment

Bar Joist Attachment Can be installed on bar joists or I-beams Thumb spring retainer allows for ease of positioning Snap-off bolt head helps enable easy installation and inspection of seismic sway braces No assembly required No loose parts Meets NFPA -13 requirements for seismic sway bracing CSBBARJEG 4354 CSBBARJHD Finish Flange Thickness FT A B C Electro-galvanized 6,4 12,7 mm 50,8 mm 76,2 mm 63,5 mm Hot-dip galvanized 6,4 12,7 mm 50,8 mm 76,2 mm 63,5 mm UL Loads Brace Direction to Structure Size Rating Parallel 25-250 mm Perpendicular 25-300 mm 16630 N FM Loads Horizontal Capacity per Intallation Angle from Vertical Brace Direction Size 30-44 45-59 60-74 75-90 Parallel 6270 N 9385 N 11300 N 12590 N Perpendicular 77 N 7605 N 9165 N 230 N 5

Adjustable I-Beam Attachment No loose parts No assembly required Snap-off bolt head helps enable easy installation and inspection of seismic sway braces Meets NFPA -13 requirements for seismic sway bracing Flange Thickness FT A Height H Length L Width W CSBIB075085EG 4365 6,4 19,1 mm 0 216 mm 63,5 mm 304,8 mm 69,9 mm CSBIB075145EG 4366 6,4 19,1 mm 216 368 mm 63,5 mm 431,8 mm 69,9 mm CSBIB125180EG 4367 19,1 31,8 mm 0 457 mm 88,9 mm 546,1 mm 79,4 mm UL Loads Brace Direction to Structure Size Rating Parallel 25-300 mm Perpendicular 25-300 mm 16630 N FM Loads Horizontal Capacity per Installation Angle from Vertical Brace Direction Size Parallel 7,205 N 7,605 N 4,495 N 4,9 N Perpendicular 7,205 N,230 N 12,545 N 13,965 N 30-44 45-59 6 60-74 75-90

Multi Attachment Disperses load over two anchors Minimizes the number of installed braces needed for concrete and wood structures Ideal for deck installations Use for both lateral and longitudinal sway brace applications Meets NFPA -13 requirements for seismic sway bracing Article Number Hole Size 1 HS1 Hole Size 2 HS2 A B C D UL Listed Load CSBMA050050EG 4371 304,8 mm 63,5 mm 63,5 mm 228,6 mm 16.636 N CSBMA050075EG 4372 20 mm 304,8 mm 63,5 mm 63,5 mm 228,6 mm 16.636 N Mount to structure using holes indicated in HS1. 7

Strut Seismic Hinge Complete hinge assembly Ideal for attaching sway bracing to MEP system supports Attaches to strut trapezes and to structure Hole Size 1 HS1 Hole Size 2 HS2 Length L Width W Thickness T CSBSH00375EG 4463 11 mm 179,8 mm 41,3 mm 6,4 mm CSBSH00500EG 4464 179,8 mm 41,3 mm 6,4 mm CSBSH00625EG 4465 17 mm 179,8 mm 41,3 mm 6,4 mm CSBSH00750EG 4466 21 mm 179,8 mm 41,3 mm 6,4 mm 8

Universal Structural Attachment Universal design allows one product to attach directly to concrete, wood, bar joist or I-beam adapters Snap-off bolt head helps enable easy installation and inspection of seismic sway braces Use for both lateral and longitudinal sway brace applications Works with 1" through 2" brace pipes and 1/4" angle iron braces to reduce inventory Center bolt does not require tightening Meets NFPA -13 requirements for seismic sway bracing Hole Size HS A B C CSBUNIV050EG 47 133,4 mm 1,6 mm 41,4 mm CSBUNIV075EG 49 21 mm 133,4 mm 1,6 mm 41,4 mm UL Loads Brace Type Size Rating Pipe 25 mm - 250 mm 13,3 N 6mm Thick Angle 25 mm - 200 mm 8,960 N FM Loads Brace Type Size Pipe Horizontal Capacity per Installation Angle from Vertical 30-44 45-59 60-74 75-90 7,205 N,230 N 12,545 N 13,965 N 9

Shear Bolt Description CSBBARJSB50EG 2502 Shear Bolt for Bar Joist Attachment CSBIBSB50EG 2501 Shear Bolt for I-Beam Attachment CSBUNIVSB62EG 2503 Shear Bolt for Universal Sway Brace and Universal Structural Attachment Shear Nut Description CSBIBSN37EG 2500 Shear Nut for Adjustable I-Beam Attachment CSBQIKCLSN37EG 2505 Shear Nut for Quick Grip Jr. Lateral Sway Brace, 25-50 mm NB/DN

Sway Braces Easy Universal Sway Brace Standard Universal Sway Brace Quick Grip Jr. Lateral Sway Brace Quick Grip Lateral Sway Brace Easy Universal Sway Brace Use for both lateral and longitudinal sway brace applications Unique slotted holes provide for easy slip-on installation eliminating loose hardware Snap-off bolt head helps enable easy installation and inspection of seismic sway braces Works with 1" through 2" brace pipes and 1/4" angle iron braces to reduce inventory Meets NFPA -13 requirements for seismic sway bracing Pipe Size NB/DN A B Listings Approvals CSBEZU00EG 4356 1" 25 mm 174,6 mm 25,4 mm UL, FM CSBEZU0125EG 4357 1 1/4" 32 mm 187,4 mm 25,4 mm UL, FM CSBEZU0150EG 4358 1 1/2" mm 196,9 mm 25,4 mm UL, FM CSBEZU0200EG 4359 2" 50 mm 206,4 mm 30,2 mm UL, FM CSBEZU0250EG 4360 2 1/2" 65 mm 225,4 mm 30,2 mm CSBEZU0300EG 4361 3" 80 mm 238,1 mm 30,2 mm CSBEZU00EG 4362 4" 0 mm 269,9 mm 38,1 mm CSBEZU0500EG 4363 5" 125 mm 308 mm 38,1 mm CSBEZU0600EG 4364 6" 150 mm 346,1 mm 50,8 mm 11

UL Loads (Listed for Restraints) Dyna-Flow Sch Sch CSBEZU00EG CSBEZU0125EG CSBEZU0150EG UL Loads (Listed for Sway Braces) Lateral Longitudinal Dyna-Flow EZ FLOW Sch Sch CSBEZU0200EG CSBEZU0250EG CSBEZU0300EG CSBEZU00EG CSBEZU0500EG CSBEZU0600EG Dyna-Flow Mega-Flow Sch Sch 5620 N 5620 N 5620 N 5620 N 5620 N 5620 N 5620 N 5620 N 5620 N 71 N 71 N 71 N 71 N 71 N 71 N FM Loads (Lightwall, Sch and Sch s) Horizontal Capacity per Installation Angle from Vertical Lateral Longitudinal 30-44 45-59 60-74 75-90 30-44 45-59 60-74 75-90 CSBEZU00EG 3825 N 5425 N 6670 N 7430 N 1735 N 2445 N 2980 N 3335 N CSBEZU0125EG 3825 N 5425 N 6670 N 7430 N 1735 N 2445 N 2980 N 3335 N CSBEZU0150EG 3825 N 5425 N 6670 N 7430 N 1735 N 2445 N 2980 N 3335 N CSBEZU0200EG 6805 N 96 N 11790 N 13165 N 2315 N 3070 N 3690 N 4136 N CSBEZU0250EG 6805 N 96 N 11790 N 13165 N 2315 N 3070 N 3690 N 4136 N CSBEZU0300EG 6805 N 96 N 11790 N 13165 N 2315 N 3070 N 3690 N 4136 N CSBEZU00EG 6985 N 9875 N 120 N 13480 N 2800 N 05 N 4895 N 5470 N CSBEZU0500EG 6985 N 9875 N 120 N 13480 N 2800 N 05 N 4895 N 5470 N CSBEZU0600EG 8805 N 12500 N 15300 N 17080 N 3245 N 4450 N 5470 N 6095 N 12

Standard Universal Sway Brace Use for both lateral and longitudinal sway brace applications Snap-off bolt head helps enable easy installation and inspection of seismic sway braces Works with 1" through 2" brace pipes and 1/4" angle iron braces to reduce inventory Slotted design grabs service pipe for added gripping strength Meets NFPA -13 requirements for seismic sway bracing Pipe Size NB/DN A B Listings Approvals CSBSTU00EG 4385 1" 25 mm 174,6 mm 25 mm UL, FM CSBSTU0125EG 4386 1 1/4" 32 mm 187,4 mm 25,4 mm UL, FM CSBSTU0150EG 4387 1 1/2" mm 196,9 mm 25,4 mm UL, FM CSBSTU0200EG 4388 2" 50 mm 206,4 mm 30,2 mm UL, FM CSBSTU0250EG 4389 2 1/2" 65 mm 225,4 mm 30,2 mm CSBSTU0300EG 4390 3" 80 mm 238,1 mm 30,2 mm CSBSTU00EG 4391 4" 0 mm 269,9 mm 38,1 mm CSBSTU0500EG 4392 5" 125 mm 308 mm 38,1 mm CSBSTU0600EG 4393 6" 150 mm 346,1 mm 50,8 mm CSBSTU0800EG 4394 8" 200 mm 0,1 mm 50,8 mm CSBSTU00EG 4395 " 250 mm 457,2 mm 50,8 mm CSBSTU00HD 1" 25 mm 174,6 mm 25 mm UL, FM CSBSTU0125HD 1 1/4" 32 mm 187,4 mm 25,4 mm UL, FM CSBSTU0150HD 1 1/2" mm 196,9 mm 25,4 mm UL, FM CSBSTU0200HD 2" 50 mm 206,4 mm 30,2 mm UL, FM CSBSTU0300HD 3" 80 mm 238,1 mm 30,2 mm CSBSTU00HD 4" 0 mm 269,9 mm 38,1 mm CSBSTU0500HD 5" 125 mm 308 mm 38,1 mm CSBSTU0600HD 6" 150 mm 346,1 mm 50,8 mm CSBSTU0800HD 8" 200 mm 0,1 mm 50,8 mm CSBSTU00HD " 250 mm 457,2 mm 50,8 mm Finish: Hot-dip galvanized UL Loads (Listed for Restraints) Dyna-Flow Sch Sch CSBSTU00xx CSBSTU0125xx CSBSTU0150xx 13

UL Loads (Listed for Sway Braces) Lateral Longitudinal Dyna-Flow EZ FLOW Sch Sch CSBSTU0200xx CSBSTU0250xx CSBSTU0300xx CSBSTU00xx CSBSTU0500xx CSBSTU0600xx CSBSTU0800xx CSBSTU00xx Dyna-Flow EZ FLOW Sch Sch FM Loads (Lightwall, Sch and Sch s) Horizontal Capacity per Installation Angle from Vertical Lateral Longitudinal 30-44 45-59 60-74 75-90 30-44 45-59 60-74 75-90 CSBSTU00xx 3825 N 5425 N 6670 N 7430 N 4315 N 3200 N 3825 N 4270 N CSBSTU0125xx 3825 N 5425 N 6670 N 7430 N 4315 N 3200 N 3825 N 4270 N CSBSTU0150xx 3825 N 5425 N 6670 N 7430 N 4315 N 3200 N 3825 N 4270 N CSBSTU0200xx 6805 N 96 N 11790 N 13165 N 3870 N 3070 N 3690 N 4136 N CSBSTU0250xx 6805 N 96 N 11790 N 13165 N 3870 N 3070 N 3690 N 4136 N CSBSTU0300xx 6805 N 96 N 11790 N 13165 N 3870 N 3070 N 3690 N 4136 N CSBSTU00xx 6985 N 9875 N 120 N 13480 N 6895 N 6185 N 7475 N 8320 N CSBSTU0500xx 6985 N 9875 N 120 N 13480 N 6895 N 6185 N 7475 N 8320 N CSBSTU0600xx 8805 N 12500 N 15300 N 17080 N 65 N 5205 N 6270 N 6985 N FM Loads (4.8 mm wall and Sch s) Horizontal Capacity per Installation Angle from Vertical Lateral Longitudinal 30-44 45-59 60-74 75-90 30-44 45-59 60-74 75-90 CSBSTU0800xx 9075 N 12855 N 15745 N 17570 N 53 N 7560 N 9295 N 365 N CSBSTU00xx 9075 N 12855 N 15745 N 17570 N 53 N 7560 N 9295 N 365 N 14

Quick Grip Jr. Lateral Sway Brace Easy two-step installation elminates extra trips between structure and service pipe Works with 1" and 1 1/4" (25 mm and 32 mm) brace pipes to reduce inventory Snap-off bolt head helps enable easy installation and inspection of seismic sway braces Meets NFPA -13 requirements for seismic sway bracing Pipe Size NB/DN Height H Width W CSBQIKCL00EG 4373 1" 25 mm 130,2 mm 65,3 mm CSBQIKCL0125EG 4374 1 1/4" 32 mm 136,5 mm 74,4 mm CSBQIKCL0150EG 4375 1 1/2" mm 142,9 mm 80,2 mm CSBQIKCL0200EG 4376 2" 50 mm 161,9 mm 92,3 mm UL Loads (Listed for Restraints) CSBQIKCL00EG CSBQIKCL0125EG CSBQIKCL0150EG CSBQIKCL0200EG Lateral Schedule 25 mm Brace Pipe 32 mm Brace Pipe Dyna-Flow Dyna-Flow 20 N 20 N 20 N Dyna-Flow 3330 N 3330 N 3330 N Dyna-Flow 3330 N 20 N 3330 N 20 N 3330 N 20 N 15

FM Loads Lateral Horizontal per Installation Angle from Vertical Schedule Lightwall CSBQIKCL00EG CSBQIKCL0125EG CSBQIKCL0150EG CSBQIKCL0200EG 30-44 45-59 60-74 75-90 1290 N 1830 N 2200 N 2445 N 665 N 935 N 1245 N 10 N 2115 N 2960 N 3670 N 4115 N Lightwall 1290 N 1830 N 2200 N 2445 N 665 N 935 N 1245 N 10 N 2115 N 2960 N 3670 N 4115 N Lightwall 1290 N 1830 N 2200 N 2445 N 665 N 935 N 1245 N 10 N 2115 N 2960 N 3670 N 4115 N Lightwall 1735 N 2445 N 2980 N 3335 N 1555 N 2225 N 2760 N 3070 N 2180 N 3070 N 3780 N 4225 N Quick Grip Lateral Sway Brace The Quick Grip Lateral Brace, part of the CADDY line of fire sprinkler bracing systems from ERICO, is designed to help simplify installations when bracing service pipe for seismic or other catastrophic events. It features an innovative design for quick attachment of brace pipe to service pipe saving time and money. Easy two-step installation elminates extra trips between structure and service pipe Works with 1" and 1 1/4" (25 mm and 32 mm) brace pipes to reduce inventory Yellow tips provide a visual indicator that the bolts have been properly torqued Easy installation with an impact wrench from the bottom side of the clamp Meets NFPA -13 requirements for seismic sway bracing Pipe Size NB/DN Height H Width W 65 mm 138,1 148,6 mm 172 mm CSBQG0250EG 4468 2 1/2" CSBQG0300EG 4469 3" 80 mm 155 165,5 mm 190 mm CSBQG00EG 4470 4" 0 mm 180,4 190,9 mm 222 mm CSBQG0500EG 4471 5" 125 mm 205,8 217,9 mm 260 mm CSBQG0600EG 4472 6" 150 mm 235,5 244,9 mm 298 mm CSBQG0800EG 4473 8" 200 mm 289,2 300 mm 351,8 mm 16

UL Loads Lateral Schedule CSBQG0250EG CSBQG0300EG CSBQG00EG CSBQG0500EG CSBQG0600EG CSBQG0800EG 25 mm Brace Pipe 32 mm Brace Pipe Dyna-Flow Dyna-Flow Dyna-Flow Mega-Flow FM Loads Lateral CSBQG0250EG CSBQG0300EG CSBQG00EG CSBQG0500EG CSBQG0600EG CSBQG0800EG Horizontal Capacity per Installation Angle from Vertical Schedule 30-44 45-59 60-74 75-90 Lightwall 6270 N 8895 N 900 N 12190 N 6270 N 8895 N 900 N 12190 N 6270 N 8895 N 900 N 12190 N Lightwall 5295 N 7475 N 9163 N 230 N 5295 N 7475 N 9163 N 230 N 5295 N 7475 N 9163 N 230 N Lightwall 5295 N 7475 N 9163 N 230 N 5295 N 7475 N 9163 N 230 N 5295 N 7475 N 9163 N 230 N Lightwall 3870 N 5470 N 6715 N 7515 N 3870 N 5470 N 6715 N 7515 N 4315 N 6095 N 7475 N 8320 N Lightwall 3870 N 5470 N 6715 N 7515 N 3870 N 5470 N 6715 N 7515 N 4315 N 6095 N 7475 N 8320 N 4.8 mm (Wall Thickness) 3515 N 49 N 6050 N 6760 N 3515 N 49 N 6050 N 6760 N 17

Cable Bracing CADDY cable bracing is an ideal alternative to rigid bracing for fire sprinkler systems when brace lengths greater than 19-8 (6 m) are required or when confined/crowded spaces make rigid systems difficult to install. The system includes pre-stretched steel cable, attachment fittings, crimping sleeves and related tools. The system can also be used to brace electrical, mechanical and plumbing systems. Color-coated cable conforms to NFPA 13 requirements and makes it highly visible and easier to identify cable sizes UL Listed OSHPD Pre-Approved (OPA-0619) Cable Spool Crimping Sleeve Loop Attachment Kit No Pry Clip Stake Eye Kit Cable Cutter 18

Swaging Tools Universal Restraint Clip Universal Restraint Clip, Retrofit Cable Spool Cut to length as needed Pre-stretched restraint cable Finish: Pre-galvanized, Painted Brace Size Diameter Cable Length UL Listed Load Color CSB12CBL 2190 #12 2,4 mm 76,2 m 2.668 N Red CSB18CBL 2191 #18 3,2 mm 76,2 m 4.893 N White CSB36CBL 2192 #36 4,8 mm 76,2 m 12.455 N Blue CSB48CBL 2193 #48 6 mm 76,2 m 20.461 N Yellow Cable is powder coated. 19

Crimping Sleeve Creates secure loop ends Crimp with swaging tools Material: Copper Brace Size CSB12SLVB 2194 #12 CSB18SLVB 2195 #18 CSB36SLVB 2196 #36 CSB48SLVB 2197 #48 Two side-by-side crimps required on #12 and #18 cable. Three side-by-side crimps required on #36 and #48 cable. Check crimp with gauge (not included). Loop Attachment Kit Two-way bracing kit with crimp sleeves Wraps around structural steel members Brace Size Brace Length Cable Length UL Listed Load Color CSB12B00L7 2230 #12 2,1 m 3,3 m 2.668 N Red CSB12B00L 2232 #12 3,0 m 4,2 m 2.668 N Red CSB18B00L7 2231 #18 2,1 m 3,3 m 4.893 N White CSB18B00L 2233 #18 3,0 m 4,2 m 4.893 N White Stake eyes not included. 20

No Pry Clip Eliminates prying effect on fasteners and anchors CSBNPC12 2208 Brace Size Hole Size UL Listed Load #12, #18, #36 12.460 N Stake Eye Kit Attaches to steel, wood or concrete structures Two-way bracing kit with crimp sleeves and stake eyes Swaged-on stake eye, pre-bent to 45 degrees Article Number Brace Size Hole Size Brace Length Cable Length UL Listed Load Color CSB12BD38L7 2218 #12 11 mm 2,1 m 3,3 m 2.668 N Red CSB12BD38L 2221 #12 11 mm 3,0 m 4,2 m 2.668 N Red CSB12BD50L7 2224 #12 2,1 m 3,3 m 2.668 N Red CSB12BD50L 2227 #12 3,0 m 4,2 m 2.668 N Red CSB18BD38L7 2219 #18 11 mm 2,1 m 3,3 m 4.893 N White CSB18BD38L 2222 #18 11 mm 3,0 m 4,2 m 4.893 N White CSB18BD50L7 2225 #18 2,1 m 3,3 m 4.893 N White CSB18BD50L 2228 #18 3,0 m 4,2 m 4.893 N White CSB36BD38L7 2220 #36 11 mm 2,1 m 3,3 m 12.455 N Blue 21

Article Number Brace Size Hole Size Brace Length Cable Length UL Listed Load Color CSB36BD38L 2223 #36 11 mm 3,0 m 4,2 m 12.455 N Blue CSB36BD50L7 2226 #36 2,1 m 3,3 m 12.455 N Blue CSB36BD50L 2229 #36 3,0 m 4,2 m 12.455 N Blue Kits contain copper sleeves. 22

Swaging Tools Manual Swaging Tool Multi-Size Manual Swaging Tool Manual Swaging Tool Brace Size Listings CSB12SBHS 4461 #12 - CSB48 2212 #48 UL 23

Multi-Size Manual Swaging Tool CSB3346SB Brace Size 2209 #12, #18, #36 Universal Restraint Clip Attaches cable brace to structure Brace Size Hole Size HS UL Listed Load CSBURC38 2198 #12, #18, #36 11 mm 7.117 N CSBURC12 2199 #12, #18, #36 7.117 N CSBURC58 2200 #12, #18, #36 17 mm 7.117 N CSBURC4812 2204 #48 20.460 N CSBURC4858 2205 #48 17 mm 20.460 N CSBURC4834 2206 #48 21 mm 20.460 N Mount to the structure using the center hole. Loop cable through the holes in the bent tabs and crimp in place. For #48 cable, use two clips stacked together. 24

Universal Restraint Clip, Retrofit Slotted design ideal for attaching to existing threaded rod on trapezes Brace Size Rod Size RS CSBURCR38 2201 #12, #18 M CSBURCR12 2202 #12, #18 M12 CSBURCR58 2203 #12, #18 M16 One fastener required for #12 cable. Two stacked fasteners required for #18 cable. 25

Branch Line Restraint System Traditional methods for installing branch line restraints in fire sprinkler systems are cumbersome and time-consuming. Contractors often cut (and re-cut) threaded rod to precise measurements to restrain the sprinkler pipe with a loop hanger and surge restraint. Traditional methods also commonly require five or more parts per restraint. To avoid these labor-intensive methods, ERICO has streamlined the process and developed the Branch Line Restraint System, part of the CADDY line of hanging and bracing solutions for the fire protection market. Ideal for restraining 1 (25 mm) through 2 (50 mm) branch lines, this innovative system is significantly faster and easier to install than current methods. It attaches directly to steel bar joists, I-beams or purlins, as well as concrete and wood structures. The hardware is installed with only one tool, a 5/16 (8 mm) socket drill driver, which provides significant labor savings and convenience. It features a simple, two-step installation process, allowing a time savings of up to 80% compared to other methods. Unlike most solutions that only accept 3/8 (M) threaded rod, the versatile Branch Line Restraint System features a swivel attachment that can be rotated to accept 3/8 or 1/2 (M or M12) threaded rod. This allows greater restraint distances from the pipe to structure with 1/2 (M12) threaded rod. The system meets the requirements of NFPA 13, making it ideal for new construction applications. The total system is culus Listed and FM Approved, and has been pre-approved by the state of California (OSHPD OPA-2629-). Complete restraint system is quick and easy to install Offers up to 80% time savings per branch line restraint Eliminates need to cut threaded rod to exact dimensions Works with 3/8 and 1/2 (M and M12) rod Capable of restraint distances up to (960 mm) from pipe to structure with 1/2 (M12) threaded rod Meets requirements of NFPA 13 section 9.3.6 Branch Line Restraint Pipe Attachment Branch Line Restraint Structure Attachment to Steel Branch Line Restraint Structure Attachment to Wood/Concrete 26 Branch Line Restraint Structure Attachment to Threaded Hole

Branch Line Restraint Pipe Attachment Accepts 3/8 or 1/2 (M or M12) threaded rod Quick grip clamp simplifies measuring and cutting of threaded rod Works with rough-cut threaded rod and eliminates pipe-side deburring Can be installed with threaded rod above or below the service pipe Shear-off head helps ensure correct torque and simplifies inspection Article Number Pipe Size NB/DN Outer Diameter OD Rod Size RS Height H Length L Width W 169,4 mm 41,4 mm 22,2 mm CSBBRP00EG 4477 1" 25 mm 33,4 mm M, M12 CSBBRP0125EG 4478 1 1/4" 32 mm 42,2 mm M, M12 192 mm 50 mm 22,2 mm CSBBRP0150EG 4479 1 1/2" mm 48,3 mm M, M12 208,4 mm 56,1 mm 22,2 mm CSBBRP0200EG 4480 2" 50 mm 60,3 mm M, M12 2 mm 68,3 mm 22,2 mm 27

Branch Line Restraint Structure Attachment to Steel Swivel connector accepts 3/8 or 1/2 (M or M12) threaded rod Attaches to steel members with self-drilling/tapping screw CSBBRS1MEG Article Number 2239 Rod Size RS Flange Thickness FT Height H Length L Width W Screw Diameter Sc Screw Length L M, M12 2,7 12,7 mm 28,2 mm,4 mm 26,9 mm #12 32 mm Branch line structural attachments are for restraint only and not for the hanging of fire sprinkler piping. Branch Line Restraint Structure Attachment to Wood/Concrete Swivel connector accepts 3/8 or 1/2 (M or M12) threaded rod Attaches to wood or concrete structures CSBBRS2MEG Article Number 22 Rod Size RS Height H Length L Width W Screw Diameter Sc Screw Length L Drill Bit Size M, M12 28,2 mm,4 mm 26,9 mm 6,4 mm 45 mm 4,8 mm Branch line structural attachments are for restraint only and not for the hanging of fire sprinkler piping. 28

Branch Line Restraint Structure Attachment to Threaded Hole Swivel connector accepts 3/8 or 1/2 (M or M12) threaded rod Attaches to concrete anchors or structural attachments with female threads CSBBRS3MEG Article Number 2241 Rod Size RS Height H Length L Width W Screw Diameter Sc Screw Length L M, M12 28,2 mm,4 mm 26,9 mm M 19 mm Branch line structural attachments are for restraint only and not for the hanging of fire sprinkler piping. 29

Rod Stiffeners Pipe Rod Stiffener Pipe Rod Stiffener For use with Schedule or Schedule pipe Secures pipe to threaded rod for stiffening CSBRS1 2207 Brace Pipe Size Brace NB/DN Rod Size 1" 25 mm M, M12, M16 30

culus is a registered certification mark of UL LLC. Dyna-Flow is a registered trademark of Allied Tube & Conduit Corporation. EZ FLOW is a trademark of Northwest Pipe Company. FM is a registered certification mark of FM Approvals LLC, LTD. NFPA is a registered trademark of National Fire Protection Association, Inc. UL is a registered certification mark of UL LLC. WARNING ERICO products shall be installed and used only as indicated in ERICO s product instruction sheets and training materials. Instruction sheets are available at and from your ERICO customer service representative. Improper installation, misuse, misapplication or other failure to completely follow ERICO s instructions and warnings may cause product malfunction, property damage, serious bodily injury and death. WARRANTY ERICO products are warranted to be free from defects in material and workmanship at the time of shipment. NO OTHER WARRANTY, WHETHER EXPRESS OR IMPLIED (INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), SHALL EXIST IN CONNECTION WITH THE SALE OR USE OF ANY ERICO PRODUCTS. Claims for errors, shortages, defects or nonconformities ascertainable upon inspection must be made in writing within 5 days after Buyer's receipt of products. All other claims must be made in writing to ERICO within 6 months from the date of shipment or transport. Products claimed to be nonconforming or defective must, upon ERICO's prior written approval in accordance with its standard terms and procedures governing returns, promptly be returned to ERICO for inspection. Claims not made as provided above and within the applicable time period will be barred. ERICO shall in no event be responsible if the products have not been stored or used in accordance with its specifications and recommended procedures. ERICO will, at its option, either repair or replace nonconforming or defective products for which it is responsible or return the purchase price to the Buyer. THE FOREGOING STATES BUYER S EXCLUSIVE REMEDY FOR ANY BREACH OF ERICO WARRANTY AND FOR ANY CLAIM, WHETHER SOUNDING IN CONTRACT, TORT OR NEGLIGENCE, FOR LOSS OR INJURY CAUSED BY THE SALE OR USE OF ANY PRODUCT. LIMITATION OF LIABILITY ERICO excludes all liability except such liability that is directly attributable to the willful or gross negligence of ERICO's employees. Should ERICO be held liable its liability shall in no event exceed the total purchase price under the contract. ERICO SHALL IN NO EVENT BE RESPONSIBLE FOR ANY LOSS OF BUSINESS OR PROFITS, DOWNTIME OR DELAY, LABOR, REPAIR OR MATERIAL COSTS OR ANY SIMILAR OR DISSIMILAR CONSEQUENTIAL LOSS OR DAMAGE INCURRED BY BUYER. Copyright 2013 ERICO International Corporation. All rights reserved. CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH, and LENTON are registered trademarks of ERICO International Corporation. 31