THE EXTENDED N2 METHOD IN SEISMIC DESIGN OF STEEL FRAMES CONSIDERING SEMI-RIGID JOINTS

Similar documents
RELIABILITY OF SEISMIC LINKS IN ECCENTRICALLY BRACED STEEL FRAMES

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Design check of BRBF system according to Eurocode 8 Use of pushover analysis

NONLINEAR PERFORMANCE OF A TEN-STORY REINFORCED CONCRETE SPECIAL MOMENT RESISTING FRAME (SMRF)

Non Linear Analysis of Composite Beam Slab Junction with Shear Connectors using Ansys.16

Shaking Table Test of Controlled Rocking Reinforced Concrete Frames

SEISMIC VULNERABILITY ASSESSMENT OF STEEL PIPE SUPPORT STRUCTURES

RE-CENTRING DUAL ECCENTRICALLY BRACED FRAMES WITH REMOVABLE LINKS

CAPACITY BASED DESIGN OF COLD FORMED STORAGE RACK STRUCTURES UNDER SEISMIC LOAD FOR RIGID AND SEMI RIGID CONNECTIONS

Behaviour and design of innovative hybrid coupled shear walls for steel buildings in seismic areas

Research on the Influence of Infill Walls on Seismic Performance of Masonry Buildings with Bottom Frame-Shear Walls

EVALUATION OF THE NEED FOR WEAK BEAM-STRONG COLUMN DESIGN IN DUAL FRAME-WALL STRUCTURES

This point intends to acquaint the reader with some of the basic concepts of the earthquake engineer:

STUDY ON LAMINATED RUBBER BEARING BASE ISOLATORS FOR SEISMIC PROTECTION OF STRUCTURES

Journal of Asian Scientific Research EVALUATION OF RECTANGULAR CONCRETE-FILLED STEEL-HOLLOW SECTION BEAM-COLUMNS

Seismic performance assessment of reinforced concrete buildings using pushover analysis

Modelling of RC moment resisting frames with precast-prestressed flooring system

Seismic Analysis and Design of Vertically Irregular RC Building Frames

Effect of beam dimensions on structural performance of wide beam-column joints

Fagà, Bianco, Bolognini, and Nascimbene 3rd fib International Congress

DESIGN OF STEEL FRAMES OF DISSIPATIVE SHEAR WALLS

Seismic Analysis of Steel Frames with Different Bracings using ETSBS Software.

Analytical Study on Seismic Performance of Hybrid (DUAL) Structural System Subjected To Earthquake

STRENGTH REDUCTION FACTORS FOR MULTI-DEGREE-OF-FREEDOM SYSTEMS

SEISMIC PERFORMANCE OF CONCRETE TILT-UP BUILDINGS: CURRENT WALL-TO-SLAB CONNECTIONS

EQUIVALENT UNIFORM DAMPING RATIOS for Irregular in Height Concrete / Steel Structural systems

COST C26. Urban Habitat Constructions under Catastrophic Events EARTHQUAKE RESISTANCE WG 2 Session, March 30th

ANALYTICAL STUDIES OF A FULL-SCALE STEEL BUILDING SHAKEN TO COLLAPSE

THE BEHAVIOR OF ECCENTRICALLY BRACED FRAMES WITH SHORT LINKS

REHABILITATION OF RC BUILDINGS USING STRUCTURAL WALLS

NONLINEAR STATIC ANALYSIS OF R.C.C. FRAMES (Software Implementation ETABS 9.7)

Stability Analysis of Rigid Steel Frames With and Without Bracing Systems under the Effect of Seismic and Wind Loads

A COMPARISON BETWEEN THE REQUIREMENTS OF PRESENT AND FORMER ROMANIAN SEISMIC DESIGN CODES, BASED ON THE REQUIRED STRUCTURAL OVERSTRENGTH

Performance Based Seismic Design of Reinforced Concrete Building

Multi performance option in direct displacement based design

Seismic design of braced frame gusset plate connections

The Behaviour of Beam-Column Elements with Variable I Cross-Sections considering Lateral Restraints

Application of Pushover Analysis for Evaluating Seismic Performance of RC Building

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 10, 2016 ISSN (online):

OPTIMUM POSITION OF OUTRIGGER SYSTEM FOR HIGH RAISED RC BUILDINGS USING ETABS (PUSH OVER ANALYSIS)

Bahram Marabi* & Abdul Kadir Marsono

ECCENTRICALLY BRACED FRAME DESIGN FOR MODERATE SEISMIC REGIONS

Simi Aboobacker 1 and Nisha Varghese 2

Seismic Fragility of Concrete Bridges with Deck Monolithically Connected to the Piers or Supported on Elastomeric Bearings

Prediction of Initial Column Size for Reinforced Concrete Frame Buildings with Intermediate Drift

Seismic Evaluation of Steel Moment Resisting Frame Buildings with Different Hysteresis and Stiffness Models

Damage-control Seismic Design of Moment-resisting RC Frame Buildings

THE DEGREE OF ACCURACY OF MODAL PUSHOVER ANALYSIS ON DUAL SYSTEM STRUCTURE INCORPORATING SHEAR WALL INELASTICITY

ON DRIFT LIMITS ASSOCIATED WITH DIFFERENT DAMAGE LEVELS. Ahmed GHOBARAH 1 ABSTRACT

Nonlinear Finite Element Modeling & Simulation

Nonlinear Static Pushover Analysis of a Shear Wall Building in Madinah

On Improved Performance Of Eccentrically Braced Frames With Replaceable Shear Link

PERFORMANCE BASED SEISMIC EVALUATION OF MULTI-STOREYED REINFORCED CONCRETE BUILDINGS USING PUSHOVER ANALYSIS

Displacement Based Damage Estimation of RC Bare Frame Subjected to Earthquake Loads: A Case Study on 4 Storey Building

Council on Tall Buildings

Torsional Considerations in Building Seismic Design

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 2, 2011

SEISMIC SHEAR FORCE MAGNIFICATION IN RC COUPLED WALL SYSTEMS, DESIGNED ACCORDING TO EUROCODE 8

EVALUATION OF MODAL PUSHOVER ANALYSIS USING VERTICALLY IRREGULAR FRAMES

Evaluation of Seismic Behavior for Low-Rise RC Moment Resisting Frame with Masonry Infill Walls

Earthquakes Analysis of High Rise Buildings with Shear Walls at the Center Core and Center of Each Side of the External Perimeter with Opening

Seismic Performance and Design of Linked Column Frame System (LCF)

Shaking Table Model Test of a HWS Tall Building

Application of Buckling Restrained Braces in a 50-Storey Building

COMPARATIVE REPORT CYPECAD VS. ETABS

Evaluation of Earthquake Risk Buildings with Masonry Infill Panels

DYNAMIC CHARACTERISTICS ASSESSMENT OF STEEL BEAM-COLUMN CONNECTIONS WITH FLOOR SLAB

THE STRUCTURAL BEHAVIOUR OF COMPOSITE CONNECTIONS WITH STEEL BEAMS AND PRECAST HOLLOW CORE SLABS

Cable bracing design in adaptable dual control systems

Seismic Response of Infilled Framed Buildings Using Pushover Analysis

PLAN IRREGULAR RC FRAMES: COMPARISON OF PUSHOVER WITH NONLINEAR DYNAMIC ANALYSIS

optimal design of frp retrofitting for seismic resistant rc frames C. Chisari 1, C. Bedon 2 1

Torsion in tridimensional composite truss bridge decks

Nonlinear Pushover Analysis of Steel Frame Structure Dahal, Purna P., Graduate Student Southern Illinois University, Carbondale

PERFORMANCE STUDY OF RETROFITTED GRAVITY LOAD DESIGNED WALL FRAME STRUCTURES (SC-140)

Use of MSC Nastran/Patran to Study Seismic Behavior of Building Steel Shear Walls

Performance based Displacement Limits for Reinforced Concrete Columns under Flexure

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 05, 2016 ISSN (online):

Performance of Base Isolated Building

DESIGN ASPECTS AFFECTING THE SEISMIC BEHAVIOUR OF STEEL MRF BUILDINGS: ANALYSIS OF THREE CASE STUDIES

RESILIENT INFRASTRUCTURE June 1 4, 2016

ANALYTICAL ESTIMATION OF THE EFFECTIVENESS OF TUNED MASS CONTROL SYSTEM USING SHAKING TABLE EXPERIMENTS

Numerical study of shear wall behavior coupled with HPFRCC beam and diagonal reinforcements

CYCLIC TESTING OF BOLTED CONTINUOUS I-BEAM-TO-HOLLOW SECTION COLUMN CONNECTIONS

Study of P-Delta Effect on Tall Steel Structure

Seismic Assessment of an RC Building Using Pushover Analysis

P-DELTA EFFECTS ON TALL RC FRAME-WALL BUILDINGS

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 2, 2011

Effect of Column Discontinuity on Base Shear and Displacement of Structure

Determine Seismic Coefficients of Structural Using Pushover Nonlinear Analysis

Seismic Base Isolation of RC Frame Structures With and Without Infill

Steel Rigid Frame Structural Behaviour at El Mayor Cucapah (Baja California) Earthquake April 4, 2010.

NON-LINEAR FEM ANALYSIS FOR CES SHEAR WALLS

ESECMASE - SHEAR TEST METHOD FOR MASONRY WALLS WITH REALISTIC BOUNDARY CONDITIONS

CHAPTER 8 THE DESIGN AND ANALYSIS OF MULTI-STORY BUILDINGS WITH LARGE MOMENT END-PLATE CONNECTIONS 8.1 INTRODUCTION

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 2, 2011

In-plane testing of precast concrete wall panels with grouted sleeve

SEISMIC FRAGILITY CURVES FOR REINFORCED CONCRETE BUILDINGS AND BRIDGES IN THESSALONIKI

Effect of Base Isolation on the Response of Reinforced Concrete Building

DEVELOPMENT OF ACCELERATED BRIDGE CONSTRUCTION DETAIL FOR SEISMIC REGIONS. W. Phillip Yen 1 and Amjad Aref 2

Transcription:

THE EXTENDED N2 METHOD IN SEISMIC DESIGN OF STEEL FRAMES CONSIDERING SEMI-RIGID JOINTS Paulina KROLO 1, Mehmed CAUSEVIC 2 and Mladen BULIC 3 ABSTRACT In this paper the nonlinear static seismic analysis of typical steel framed structure including the real joint stiffness (instead of traditionally design with pinned or rigid joints) is presented. In order to take into account the real joint behaviour in seismic analysis nonlinear analysis using the finite element method of welded beam-to-column joint was carried out firstly. The beam-to-column joints of analysed structure was chosen according to experimental tests. The results of finite element analysis obtained in program Abaqus 6.12 are shown in the form of the moment-rotation curve. Nonlinear moment-rotation curve will be idealized by tree-linear curve for the purpose of seismic analysis. The idea of this research is to show the influence of semi-rigid joints on the seismic effects for moment resisting frames. The storey drifts and displacements obtained from seismic analysis for steel frame including semi-rigid joints will be compared with results for steel frame with traditionally rigid joins. INTRODUCTION The basic nonlinear static N2 method (Fajfar, 1999) which was implemented in Eurocode 8 was constantly developing. The assumption that structure vibrates predominantly in the single mode is not always fulfilled. A lot of work by several authors has been done and published worldwide extending the simple pushover-based nonlinear static N2 method by taking into account either the influence of higher modes in elevation or in plan, or in both plan end elevation, introducing the correction factors (Fajfar et al., 25, Causevic and Mitrovic 211, Kreslin and Fajfar 212). In the development of the extended N2 method mainly reinforced concrete structures have been analysed. Having in mind steel structures, beam-to-column joints of steel frames traditionally have been modelled either as ideally pinned or perfectly rigid. Such approach does not show the real structural behaviour. In this paper the basic N2 method considering semi-rigid joints (instead of traditional design with pinned or rigid joints) for steel structures is introduced. The idea of the influence of semi-rigid joints on the seismic effects for steel moment resisting frames is illustrated in Fig.1. Joint stiffness will directly influence the value of the fundamental period of structure which will be shown in further analysis. Computational procedure was applied to the 3-storey steel framed structure which details were described in the next chapter. The aim of this paper is to show results obtained from analysis (basic nonlinear static N2 method) including the joint stiffness (rigid and semi-rigid) for displacements and storey drifts. 1 Research assistant, Faculty of Civil Engineering, Rijeka, Croatia, paulina.krolo@gradri.uniri.hr 2 Professor, Faculty of Civil Engineering, Rijeka, Croatia, mcausevic@gradri.uniri.hr 3 Assistant Professor, Faculty of Civil Engineering, Rijeka, Croatia, mladen.bulic@gradri.uniri.hr 1

(a) Figure 1. Steel moment resisting frame with: (a) rigid joints and (b) semi-rigid joints In the first part of the analysis the application example was presented. Numerical finite element modelling of semi-rigid joints have been introduced in the second part and in the last part the seismic analysis of frame with rigid and semi-rigid joints will be presented. By taking joints as semi-rigid their behaviour became a fuse for seismic energy dissipation as it was for steel structures with eccentrically braces frames where links act as a fuse for seismic energy dissipation (Mazzolani et al. 1994, Bulic et. al. 213). (b) APPLICATION EXAMPLE This section presents the characteristics of the typical steel framed structure for which the seismic analysis will be carried out. A typical example of the steel framed structure is a Swedish model according to "Multi-storey buildings in steel - The Swedish development" (1997) which is composed of steel frames with a reinforced concrete core and prestressed concrete hollow slab floors. The columns and beams are made of H profiles. In order to achieve more slender structure, the reinforced concrete core is in these analysis replaced with steel bracing as shown in Fig.2. (a) Figure 2. Axonometric view of (a) Swedish model with reinforced concrete core; (b) Swedish model with steel bracing The seismic analysis was computed for one imaginary frame instead of all real frames representing the structure in Fig. 2 (b). in the longitudinal direction. The geometry of this steel frame is schematically shown in Fig.3. A three-storey five-bay steel frame with an inter-storey height of 3. m and bay with 5. m is considered. (b)

Figure 3. Section trough the bracing system in the longitudinal direction (geometry and type of cross section) This framed structure was analysed for two different cases. The first case uses the beam-tocolumn joints as perfectly rigid (traditionally way). In this case the structure was calculated according to shear building criteria (Chopra, 212). The second case uses the beam-to-column joints as semirigid (real joint behaviour). To reduce degrees of freedom of structure with semi-rigid joints, i. e. to reduce the stiffness matrices order the static condensation procedure is performed (Chopra, 212). In order to take into account the real joint behaviour in seismic analysis, numerical simulation of beam-to-column joints were carried out firstly. FINITE ELEMENT MODELLING OF SEMI-RIGID JOINT In this section the numerical finite element model of welded beam-to-column joints was presented. Shape of the structural system of beam-to-column joint was chosen according to experimental tests published by Skejic et al. (28) and presented in the Fig. 4. (b) (a) Figure 4. (a) Numerical finite element model of welded beam-to-column joint; (b) Shape of structural system with boundary conditions and force position (dimension in mm) (b)

Numerical model is based on a 3D materially nonlinear analysis using the finite element software ABAQUS 6.12. Eight-node solid element C3D8R is used in the modelling of the beam, column and welds. Detail of mesh and geometry are shown in the Fig. 4. (a) and (b). The finite element mesh was more refined near the welds. Two types of steel were considered, one for the beam and column and another for the welds. Stress and strain response for the first material was taken to be nonlinear, and for the second to be bilinear with Young`s modulus of 21 MPa. Stress and strain relationship for nonlinear behaviour is presented in the Fig. 5. Stress [MPa] 5 45 4 35 3 25 2 15 1 5,5,1,15,2,25,3,35 Strain [-] Beam and column material Figure 5. Stress-strain relationship for steel (nonlinear material) The model was analysed for the effect of the bending moment. Bending moment was simulated as a force applied at 1 mm distance from the joint centre (or 85 mm from connection) which acts on the upper side of the top flange of the beam. The load was modelled as 14 concentrated forces which linear growth through the 22 steps. The total force value in the last step was 14 kn. During the load action on the finite element model, deformations of beam and column were occurring. Fig.6. shows the deformed finite element model. Figure 6. Detail of deformed joint with finite element mesh

Initial and deformed shape is shown in the Fig.7. Total rotation of joint ( ) can be calculated from vertical displacement in the point beneath the load action as shown in Fig.8. Rotation of connection was calculate from Eq.(1). where ϕ=rot b - b el - Rot H1 (1) Rot b is the total rotation of joint with elastic beam rotation b el which was calculating by Eq. (2), b el is the elastic beam rotation which was calculate by Eq.(3), Rot H1 is the column web panel rotation due to shear which was calculate by Eq.(4). where Rot b= δ 1 85 δ 1 is the vertical displacement in the point beneath the load action. (2) where b el = FL F 2 2EI b (3) F is the concentrated forces, L F is the distance between load and external column surface which is connected for a beam, E is the Young`s modulus, is the moment of inertia. I b Rot H1= δ 3-δ 2 z (4) where δ 2 and δ 3 are horizontal displacement of column flanges due to shear action obtained from Fig. 7. Figure 7. Initial and deformed shape of joint

Figure 8. Total rotation of joint Final results are shown in the moment-rotation curve in Fig.9. (a). Initial rotational stiffness is considered as 6465.5 knm/rad. According to Eurocode 3, here obtained stiffness of joint belongs to the semi-rigid zone as shown in the Fig.9. (b). Nonlinear moment-rotation curve is idealised by three-linear curve according to Wang et al. (213) for the seismic analysis purpose. Moment [knm] 16 15 14 13 12 11 1 9 8 7 6 5 4 3 2 1,2,4,6,8 Rotation ϕ [rad] (a) Figure 9. (a) Moment-rotation curve for semi-rigid joints and (b) classification of joints by stiffness 3 1 4 2.25 1 4 1.5 1 4 7.5 1 3 Upper limit for semi-rigid-joint Lower limit for semi-rigid joint Stiffness of semi-rigid joint 2.5 1 3 5 1 3 7.5 1 3.1 (b) THE NONLINEAR STATIC SEISMIC ANALYSIS In this section the impact of rigid and semi-rigid joints on the seismic behaviour of the steel framed structure using a pushover based nonlinear static analysis approach (N2 method) is presented. The seismic demand was computed with reference to the Eurocode 8 and basic characteristics of seismic load are given in Table 1. Table 1. Basic characteristics of seismic load Elastic response spectrum Type 1 Ground type Peak ground acceleration Damping ratio B =,254 =4% In the first case of frame analysis which uses the beam-to-column joints as perfectly rigid (traditionally way), the structure was calculated according to shear building criteria (Chopra, 212). The second case of the frame analysis which uses the beam-to-column joints as semi-rigid in which the rotation of stores are taken into account. To reduce degrees of freedom of structure with semi-rigid

joints, i. e. to reduce the stiffness matrices order the static condensation procedure is performed. The obtained value of the fundamental period of steel frame with rigid and semi-rigid joints are given in the following Table 2. Table 2. Value of fundamental period Type of frame Steel frame with rigid joints Steel frame with semi-rigid joints Fundamental period T1 [s].82 1.2 Fig.1. shows the position of fundamental period for steel frame on the elastic response spectrum curve. 1.9.8 Type 1 elastic response spectrum for ground type B (4% damping) Fundamental period for steel frame with rigid joints Fundamental period for steel frame with semi-rigid joints.7 Sae [g].6.5.4.3.2.1.2.4.6.8 1 1.2 1.4 1.6 1.8 2 2.2 2.4 2.6 2.8 3 Figure 1. Fundamental period on the elastic response spectrum for steel frames with rigid joints (blue line) and semi-rigid joints (green line) The base shear-top storey displacement relationship (capacity curve) was obtained by gradually increasing the lateral forces triangular distributed over the stores (pushover). Pushover analysis was performed in SeismoStract software Version 6 on the imaginary frame representing the structure, Fig.11. T [s] Figure 11. The steel frame structure with triangular distributed lateral force

The capacity curve was transformed into capacity curve of equivalent single-degree-of-freedom (SDOF) system and was idealized as bilinear curve according to Fajfar (1999) and Eurocode 8 implementing the equal-energy concept. Fig.12. shows the capacity curve obtained from pushover analysis for steel frame with rigid joints and semi-rigid joints. 5. 4.5 4. 3.5 3. V [kn] 2.5 2. 1.5 1. 5 Capacity curve for steel frame with rigid joints Capacity curve for steel frame with semirigid joints,,5,1,15,2,25,3,35,4,45 Figure 12. Capacity curve obtained from pushover analysis for steel frame with rigid joints (blue line) and semirigid joints (green line) Target displacement for the SDOF system for steel frame with rigid joints amounts to 7.4 cm and for frame with semi-rigid joints amounts to 11.3 cm. If these values are transformed back into the MDOF system (3 DOF), 9.5 cm for steel frame with rigid joints and 14.5 cm for frame with semi-rigid joints are obtained. The steel frame is again subjected to lateral load but now for the value of the target displacement. Finally, results of displacements and storey drifts was obtained, which is shown in the Table 1. and Fig. 13. (a) and (b). d[m] Table 1. Results of displacement and storey drifts Storey Height of storey [m] Steel frame with rigid joints Displacement [cm] Steel frame with semi-rigid joints Steel frame with rigid joints Storey drift [cm] Steel frame with semi-rigid joints 3 9 9.5 14.5 2. 4.6 2 6 7.5 9.9 3.3 6.1 1 3 4.2 3.8 4.2 3.8

9 9 Storey height [m] 6 3 Storey height [m] 6 3 1.5 3 4.5 6 7.5 9 1.5 12 13.5 15.8 1.6 2.4 3.2 4 4.8 5.6 6.4 7.2 8 Storey displacements [cm] Storey drifts [cm] (a) (b) Figure 13. (a) Displacements of steel frame with rigid joints (blue line) and semi-rigid joint (green line); (b) storey drifts of steel frame with rigid joints (blue line) and semi-rigid joint (green line) CONCLUSION The focus of this study was to determine and compare the absolute and storey drifts of steel framed structures with rigid and semi-rigid joints subjected to seismic action. For the analysis with semi-rigid joints, real behaviour of joints obtained by numerical analysis using finite element method in Abaqus software were taken into account. The steel frame was analysed for nonlinear static method (pushover) by using SeismoStruct software. Taking into account the real stiffness of semi-rigid joints in seismic analysis, the displacements and storey drifts were increased in regard to results for steel frame with rigid joints, i. e. the top displacement of the steel frame with semi-rigid joints were grater for 52.6 % in regard to steel frame with rigid joints. Maximum storey drift for the steel frame with rigid joints is on the first storey, while for the steel frame with semi-rigid joints decreases on the first storey and increases on upper storeys. The third storey shows the largest deviation for the 13 %. Future plans are to develop the extension N2 method for steel structure considering semi-rigid joints by means of correction factors. The idea is to show the effect of semi-rigid joins on the low and high rise structures, especially those for which the influence of higher modes of vibration is significant. This paper presents part of results in research of extension the applicability of the pushover-based N2 method to steel moment resisting frames with semi-rigid joints with the approach to create relatively simple procedure, i. e. simpler than the nonlinear response-history analysis. Taking into account real semi-rigid joints the structural capacity was decreased, Fig. 12. In spite of that the structural security is still good enough because fundamental period increased having the consequence decrease of earthquake loading in demand spectra, Fig. 1, i. e. decrease of loading on structure in comparison to the loading obtained for structure with rigid joints. However, the advantage of taking joints as semi-rigid reflects is increasement of energy dissipation capacity for the whole structure. By taking joints as semi-rigid their behaviour became a fuse for seismic energy dissipation as it was for steel structures with eccentrically braces frames where links act as a fuse for seismic energy dissipation (Mazzolani et al. 1994, Bulic et. al. 213).

ACKNOWLEDGMENT The research presented in this paper was done within the research project "Development of structures with increased reliability with regard to earthquakes" supported by the University of Rijeka, Croatia (grant no. 42-1/14-1/11). REFERENCES Bulic M, Causevic M and Androic B (213) Reliability of short seismic links in shear, Bulletin of Earthquake Engineering, 11:183-198 Causevic M and Mitrovic S (211) Comparison between non-linear dynamic and static seismic analysis of structures according to European and US provisions, Bulletin of Earthquake Engineering, 9(2): 467-489 Chopra A.K. (212) Dynamics of Structures - Theory and Application to Earthquake Engineering, 4 th Ed., Prentice Hall, New Jersey Eurocode 3 (25) Design of steel structures, Part 1-8: Design of joints, European Committee for Standardization, CEN, Brussels Eurocode 8 (24) Design of structures for earthquake resistance Part 1: General rules, seismic actions and rules for buildings, European Committee for Standardization, CEN, Brussels Fajfar P (1999) Capacity Spectrum Method Based on Inelastic Demand Spectra, Earthquake Engineering and Structural Dynamics 28, 979-993 Fajfar P, Marusic D and Perus I (25) Torsional effects in the pushover-based seismic analysis of buildings Journal of Earthquake Engineering, 9(6): 831-854 Kreslin M and Fajfar P (212) The extended N2 method considering higher mode effects in both plan and elevation, Bulletin of Earthquake Engineering, 1(2): 695-715 Mazzolani F, M, et. al. (1994) Remarks on Behaviour of Concentrically and Eccentrically Braced Steel Frames, Proceedings of the International Workshop organized by the European Convention for Constructional Steelwork in Timisoara, Romania, E&FN SPON, An Imprint of Chapman & Hall, London, 31-323 Multi-storey buildings in steel - The Swedish development (1997), European Convention for Constructional Steelwork Nº74, B-12 Brussels, Belgium Skejic D, Dujmovic D and Androic B (28) Behavior of beam-to-column joints subjected to the static load, Structural engineering and Mechanics 29, 17-35 Wang T, Wang Z, Wang J, Feng J (213) A Simplified Calculation Model for Moment-rotation Curve Used in Semi-rigid End-plate Connection, Journal of Information & Computational Science 1:11, 3529-3538