Best Practices for Collecting Soil Samples for VOC Analysis

Similar documents
EPA Method Proper Collection and Analysis of Soil Samples for Volatile Organics....Green Technology through Innovation

Volatile Organic Compounds in Solids PBM

COPY. Region4 U.S. Environmental Protection Agency Science and Ecosystem Support Division Athens, Georgia

Driving ISM Laboratory Processing Selection with Project Goals

SW 846 METHOD 5035 FIELD SAMPLING GUIDE

State of Alaska DEPARTMENT OF ENVIRONMENTAL CONSERVATION DIVISION OF SPILL PREVENTION AND RESPONSE CONTAMINATED SITES PROGRAM

iuu "ULF ö»tftiböti6tj «A* tfcusrr Approred for public releas«; DtettUbüäon UnUmifecl

Available Laboratory Methods for Soil Gas Analysis

Passive Monitoring: A Guide to Sorbent Tube Sampling for EPA Method 325. Nicola Watson July 2015

INSTRUCTIONS & CALIBRATION PHOTOBOOK

Surface Water Samples: Containers, Preservation and Hold Times Table

Soil Vapor Installation

Optimization of Volatile Petroleum Hydrocarbons Analysis by Automated Headspace Using Method Development Tools

INTERNATIONAL STANDARD

Protocol for Quantitative Determination of Residual Solvents in Cannabis Concentrates Prepared by: Amanda Rigdon, May 23 rd, 2016

Completing. By the end of this chapter, you will be able to: Introduction. Chapter 16

Investigation Requirements for Ethanol-Blended Fuel Releases Petroleum Remediation Program

Soil Gas Analytical Methods (Overview, TAGA, Forensics)

APPENDIX K. Information sources that may be useful for identification of available water sources that could be selected as sampling locations include:

No-loss soil corer for soil with volatile components

U.S.EPA REGION 9 LABORATORY RICHMOND, CALIFORNIA FIELD SAMPLING GUIDANCE DOCUMENT #1205 SOIL SAMPLING

INTEGRITY OF VOA-VIAL SEALS

Soil sample collection and analysis procedures Petroleum Remediation Program

ITRC ISM Team (90 members)

WBEA Standard Operating Procedure

VWR CO 2 RESISTANT TUBES

The Simultaneous Analysis of Benzene, Toluene, Ethylbenzene, o,m,p-xylenes and Total Petroleum Hydrocarbons in Soil by GC-FID after Ultra-Sonication

Agilent 7820A GC System THE EASY CHOICE FOR ROUTINE ANALYSES

2. Crystallization. A. Background

CHROMATOGRAPHY/MASS SPECTROMETRY

Total Petroleum Hydrocarbons in Vapor: Seeing the Forest for the Trees

SCION GC Series. The Gas Chromatographers Choice for Separations

Industrial Services. Minimizing Downtime. Maximizing Performance. LDAR. Leak Detection and Repair (LDAR) Services

Vapor Intrusion Assessment A Comparative Analysis of Subsurface Vapor Sampling Methods

Low-level Detection of Ethanol, 1,4-Dioxane, and Other Oxygenates Using the Eclipse Purge-and-Trap Sample Concentrator

PVI Risk Pathway: Sampling Considerations

Analysis of USP <467> Residual Solvents using the Agilent 7697A Headspace Sampler with the Agilent 7890B Gas Chromatograph

Special Specimen Collection Procedures for Coagulation Testing

Can your unit pass a Particulate Emission Compliance Test?

Title: Standard Operating Procedure for the Collection of VOCs in Ambient Air Using Summa Canisters and Xontech Sampler

Is this the maturation Phase of Vapor Intrusion Investigations?

Torch Combustion TOC Analyzer

SOURCES OF VARIABILITY IN DISSOLVED METHANE CONCENTRATIONS AT RESIDENTIAL WATER WELLS

Technical Note TN-114 rev 16 wy/wh.11-04

Neural Stem Cells (ipsc from Blood Cells; Male)

Carbonyl compounds and VOCs analysis from vehicle exhaust: Conventional and alternative methods of detection, analysis and quantification

October 9, U. S. Army Corps of Engineers Omaha District Attn: CENWO-ED-ED (Jeffery Skog) 215 North 17 th Street Omaha, NE

Florida Department of Environmental Protection. Field and Lab Audits

SP-100 Equipment Wash SP-110 Tool Cleaner SP-120 Internal Storage Lubricant

For ethidium bromide waste that is generated at Harvard, each waste stream is to be managed or accumulated as described below.

Ainvolved in many aspects of project planning, sample collection,

METHOD 25D - DETERMINATION OF THE VOLATILE ORGANIC CONCENTRATION OF WASTE SAMPLES. NOTE: Performance of this method should not be

BSK Labs Frequently Asked Questions

Appendix B AMEC Laboratory Quality Assurance/Control Program

MEMORANDUM DEPARTMENT OF ENVIRONMENTAL QUALITY. Guidance Memo No Chain of Custody Policy and Procedures

Abstract. Thomas R. Eschner and David Dinsmore, Woodard & Curran.

Quantos Solutions Weighing & Dispensing Accurate Reliable Cost-Effective

Why are you making the measurement? Methods for measuring plant uptake of chemicals: lab and field. General considerations. What are you measuring?

3 700-Series Hybrid Products:

In situ Remediation of 1,4-Dioxane using Electrical Resistance Heating

Case Study Palermo Well Field Use of Stable Isotopes Tumwater, Washington

Quantos Solutions. Gravimetric Sample Preparation (GSP) Automated Weighing

Don t Settle for just any Mercury Analyzer...Go with the Experts in Mercury Analysis...Go with Teledyne Leeman Labs

MULTI-INCREMENT SAMPLING: What It Is And What It Does For Site Characterization And Risk Assessment

Humate-Induced Remediation of Petroleum Contaminated Surface Soils - Annual Report

MILESTONE. UltraWAVE MILESTONE. The Game Changer in Microwave Digestion

Super Clean Gas Filters Simply the best

Benchmark performance of Thermo Scientific Matrix 2D-barcoded cryostorage tubes

Evaluation of Spatial and Temporal Variability in VOC Concentrations at Vapor Intrusion Investigation Sites.

ATT-42/95 SAMPLING, Asphalt

ICP Expert software. Technical Overview. Introduction

Construction. Sodium silicate based surface hardener, dustproofer, sealing and curing compound for concrete. Product Description.

Pharmaceutical and Biotechnology Services

Using the PPM2 Portable Trace Moisture Transmitter

ASTM E96 VS. F1249 WHICH PROVIDES MORE ACCURATE TEST RESULTS?

BioTector System-C. Online TOC Analyzer for Clean Water Applications

Refer to Substrates & Surface Preparation.

GEOTECHNICAL INVESTIGATION I-15 SIGN BRIDGES LAS VEGAS EA JANUARY

Formulas: See Table 1 MW: Table 1 CAS: Table 1 RTECS: Table 1. METHOD: 2555, Issue 1 EVALUATION: PARTIAL Issue 1: 15 March 2003

Originally Presented at the 2005 ISMI Symposium on Manufacturing Effectiveness Scott Stewart Sr. Environmental Engineer Intel Corporation

What Determines water Quality? Well Maintenance Well water Testing AZ survey on individual systems water quality Final remarks

Agilent 7693A Series Automatic Liquid Sampler. Inject new performance into your gas chromotography

Cryogenic Homogenizing System

Plastic Storage Bottles Product Selection Guide

Over & Under Plus Floor Sealer

PermeOx. Plus. Enhanced Aerobic Biodegradation

Experiment 2: The Chromatography of Organic Compounds

Volatile organic compounds Water No CAS Number assigned

1-800-ICE-BRIX

DRAFT Procedures for Quantifying Fugitive VOC Emission Sources at Petroleum Facilities

Agilent 7693A Series Automatic Liquid Sampler INJECT NEW PERFORMANCE INTO YOUR GAS CHROMATOGRAPHY

ICAC MARAMA Portable Emission Analyzers

GUIDELINES FOR THE PACKAGING AND STORAGE OF PESTICIDES FOOD AND AGRICULTURE ORGANIZATION OF THE UNITED NATIONS

Managing Hazardous Chemical Waste

Strong Acid Leachable Metals (SALM) in Soil - Prescriptive

Aliphatic Acrylic-Polyester Polyurethane

Agilent 7693A Series Automatic Liquid Sampler INJECT NEW PERFORMANCE INTO YOUR GAS CHROMATOGRAPHY

Sampling of Cartoned Meat and Preparation for Chemical Lean Determination

HOLE SAMPLING & MONITORING. www. .com MINERAL EXPLORATION ENVIRONMENTAL GEOTECHNICAL GEOTHERMAL ROTARY SONIC HDD

PILOT PROJECT «ILE DE FRANCE»

Transcription:

Best Practices for Collecting Soil Samples for VOC Analysis David Kaminski - QED Environmental Systems Inc. Sarah Conard - En Novative Technologies Today s Webinar Topics The science behind collecting high-quality soil samples for VOCs why it matters Collecting and handling soil cores to minimize losses Standards and methods for collecting soil VOC samples Overview and comparison of soil sampling methods The En Core sampler how it works, how it compares to field preserved samples Collecting better field preserved samples using Terra Core and EasyDraw samplers Q&A session 1

TCE Concentration (% recovery) 3/8/2016 Good soil VOC data begins with good sampling practices As with all environmental samples, the laboratory data are only as good as the samples collected in the field When it comes to sampling soils for VOCs, everything we do from the time the soil cores are retrieved to the preparation of the sample for shipment can affect VOC recovery and sample quality Soil samples for VOCs can show significant losses within seconds to minutes of opening soil cores Handling cores and sample preparation methods can contribute to additional losses Using a sampling method that doesn t maintain VOCs during sample collection, shipment and during the hold before analysis adds to the problem Volatilization losses occur within seconds of exposure Uncontrollable volatilization for samples with a large surface to mass ratio Exposure Time (min) Losses in trichloroethylene from soil during sample collection, storage and laboratory handling; Hewitt, A. D., U.S. Army Cold Regions Research and Engineering Lab, Hanover, NH; 1994; SR94-8 2

Concentration µg/kg 3/8/2016 Handling of samples when a soil core liner is opened Managing sampling from a soil core can be a complex situation - stability of VOCs in the core depends on factors such as: 1. whether the soil is consolidated (e.g., clay, till) or unconsolidated (e.g., sand, gravel) 2. time that the core is open or exposed before sampling (off-gassing) 3. moisture content of the soil 4. disturbance of integrity of the core 5. ambient temperature 6. heat generated by the soil coring method (e.g., sonic drilling) VOC stability at 5% soil moisture content Time in Seconds Source: En Novative Technologies, Inc. internal research; Dr. David Turriff 3

VOC stability at 10% soil moisture content Source: En Novative Technologies, Inc. internal research; Dr. David Turriff Best practices when sampling with acrylic soil core liners Cap the acrylic liner to preserve VOCs, don t split until ready to sample Split liner as soon as possible every minute counts! Keep liner on ice if extended times are required Sample immediately with En Core or field-preserved vials upon opening liner Screen the core and select samples for analysis; USEPA SW 846 Method 3815 is the current method for screening, although its use is not mandatory 4

Things to avoid when sampling with acrylic soil core liners Leaving the liner exposed while screening Sampling from the container used for screening Taking a second boring for samples after screening the initial boring - no guarantee that samples will match from different locations Using bulk sampling rather than sealed or fieldpreserved sampling methods Avoid using soil samplers without core barrel liners Soil sampling tools used without core barrel liners, such as split spoon samplers, make it nearly impossible to retain VOCs before samples are collected, even using proper sampling methods and procedures. 5

A quick poll How long does it take you to sample from the time you open a soil core? a) Less than a minute b) 1 3 minutes c) 3 5 minutes d) 5 10 minutes e) More than 10 minutes ASTM Standards and EPA methods for soil VOC sample collection Standards of practice for obtaining, handling and screening of soil cores ASTM Standards D6282 and D6640 cover collection and handling of soil cores for environmental sampling Sample collection, preservation, transportation, and analysis US EPA Method 5035, various state guidance documents ASTM Standard D4547 Sampling Waste & Soils for VOCs ASTM Standard D6418 En Core Sampling for VOCs in Soils The Nielsen Environmental Field School offers an online training module for soil sampling practices (www.envirofieldschool.com) 6

Methods for sampling soils for VOC analysis Bulk sampling method No core liner or brass sleeve liner Sample is scooped or sliced from soil cores and packed in wide-mouth jar without preservation Lab prepares a weighed sub-sample prior to analysis Sub-core samples (5 25 grams) collected in field and placed in prepreserved VOA vials for analysis En Core Sampler sealed chamber, no field preservation required samplers are shipped to lab for analysis Factors that affect accuracy using bulk sampling method Type of soil Microbe content of soil Grit on threads of jar Time to collect sample Air space in jar Ambient temperature Excessive hold time before sample prep & analysis Time spent in lab subsampling for 5.0 g sample Purge in water (where 5035 is not used) RANGE OF ACCURACY: 0.01-95% true value! 7

Concentration (µg/kg) Bulk Method Percent of Original Value 3/8/2016 Significant bias between bulk sampling and field preservation Concentration (µg/kg) Methanol Method Volatile Organic Compounds: Comparison of Two Sample Collection and Preservation Methods, Liikala, T.; Olsen, K.; Teel, S.; and Lanigan, D., November 1996. Biodegradation loss in bulk sample during EPA-accepted hold time Days of Analysis Degradation of Hydrocarbons in Soil Samples Analyzed Within Acceptable Holding Times, Jackson, J.; Thomey, N, May 1991. 8

US EPA Method 5035 Implemented in 1997 to standardize sampling and field preservation and avoid random error and low bias from bulk sampling Incorporates two approved methods of sample collection and preservation: Field preservation of soil core sub-samples using methanol or sodium bisulfate En Core sealed samplers with no preservation required Adoption of EPA Method 5035 by region Texas TCEQ will require Method 5035 beginning January 1, 2016 9

High Level and Low Level Methods in 5035 Samples are preserved in methanol for high level analysis concentration > 200 µg/kg Samples are preserved in sodium bisulfate for low level analysis Method Detection Limits down to 0.5 µg/kg and concentrations < 200 µg/kg Field preservation is typically done at a 1:1 ratio (weight/volume) of soil and preservative Pre-preserved vials supplied by the laboratory are weighed to allow calculation of soil sample weight Soil samples are based on volume and weigh about 5, 10, or 25 grams based on sample type Hold time for samples is 14 days when chilled @ 4 C Why are there two preservatives used in Method 5035 samples? Some state or federal regulatory programs have detection limit requirements for some analytes (e.g., benzene) that are lower than most labs can achieve with a 50:1 dilution of methanol in water On the other end of the spectrum, samples with VOC concentrations above 200 µg/kg can t be accurately quantified in a sodium bisulfate solution Unless you know that all of your samples will fall above or below the 200 µg/kg threshold, both samples are taken in the field. The lab will screen the samples to determine which to analyze. 10

A quick poll Do you screen soil core concentrations before sampling? a) Yes, with a PID, FID or other vapor analyzer b) Yes, by visual inspection c) No, we don t screen the cores, just collect samples Collecting samples for field preservation with methanol Using an EasyDraw Syringe or Terra Core sampler, place a 5 or 10 gram plug of soil into pre-preserved vial containing methanol 1:1 or greater weight/volume ratio of soil to methanol Operation must be done quickly to prevent VOC loss Tared weight of methanol vials should be verified before samples are collected EasyDraw Syringe Terra Core Sampler 11

GRO Concentration (mg/kg) 3/8/2016 Methanol preservation shows no VOC loss after 30 days Time In Days Studies of Sampling, Storage and Analysis of Soils Contaminated with Gasoline and Diesel, Turriff, D. and Klopp, C., August 1994. Collecting samples for field preservation with sodium bisulfate Using an EasyDraw Syringe or Terra Core sampler, place 5 gram plug of soil into pre-preserved vial containing 20% sodium bisulfate aqueous solution Calcareous soil types should be checked for effervescence prior to sampling or vial may explode! 1:1 or greater weight/volume soil/preservative ratio Two vials are collected (second for QC samples or replicate, since entire volume is used for analysis) Operation must be done quickly to prevent VOC loss Tared weight of pre-preserved vials should be verified before samples are collected 12

Limitations of Low Level Method under 5035 Semi-quantitative since water is a poor solvent for soil VOCs - results are biased low Can have high concentrations of acetone as an artifact in some organic soils (formed by preservative) Advantages of field preservation No further preparation of the sample is required in the laboratory prior to analysis Widely accepted by regulators VOC concentrations remain stable throughout the hold time and beyond Laboratory doesn t require any special tools or procedures to process the sample 13

Disadvantages of field preservation Vial seals can leak More experienced field staff required Difficult under adverse weather conditions More risk of error, e.g., spillage, mixing labels, etc. Vehicle exhaust fumes can contaminate methanol Shipping restrictions may apply for methanol (not typically an issue if labeled as laboratory samples and volume is less than 500 ml) En Core Sampler the best alternative to field preservation The only commercially available sampler listed in Method 5035 Meets ASTM D4547 requirements for VOC retention during permitted hold time Both a sampler and sample container 5 and 25 gram sizes Designed to collect an average weight exact weight is determined in lab Zero headspace design minimal air trapped in the sample En Core Sampler and sampling handle 14

En Core sampler components Sample Collection Handle (field) 5g sampler 25g sampler Sample Extraction Handle (lab) The En Core sampler: How it works 15

The En Core sampler: How it works The En Core sampler: How it works 16

The En Core sampler: How it works The En Core sampler: How it works 17

The En Core sampler: How it works The En Core sampler: How it works 18

The En Core sampler: How it works The En Core sampler: How it works 19

The En Core sampler: How it works A quick poll What method do you use most often to sample soils for VOCs? a) Bulk sampling in jars, no preservation b) Field preserved sampling (methanol & sodium bisulfate) c) En Core sampling (no preservation required) 20

Advantages of the En Core Sampler Faster less field time needed More sample throughput Easy to use, minimal training No handling of preservative in the field No shipping restrictions Sample is preserved later in controlled laboratory setting, avoids random error from field preservation Long shelf life no expiration Ships in a proprietary VOC-proof bag that is also used to ship En Core samples to the laboratory Advantages of the En Core Sampler Recognized in ASTM Standards D4547 and D6418 The ONLY non-preserved sampler to pass ASTM specified validation method in the standard Allowed as an alternative to field preservation in every state that has accepted or requires Method 5035 Often used to minimize liability consistency of sampling despite variations in experience of field staff 21

Percent recovery comparison of two non-methanol samplers Source: En Novative Technologies, Inc. internal research; ASTM D4547 methodology Disadvantages of the En Core Sampler Samples must be preserved at the lab within the 48- hour hold time stated in Method 5035, however, if the En Core sampler is used for other programs: ASTM D4547 describe extending hold time up to 14 days by freezing samples to -12 ± 5 C ASTM D6418 describes extending hold time up to 14 days by freezing samples at -7 to -21 C, or holding for 48 hours at 4 ± 2 C followed by storage at -7 to -21 C for up to five days Samples are reported in dry weight, so a small jar of soil should be collected to measure soil moisture Per-sample cost is higher than field preservation Some offset by time savings, especially for inexperienced sampling technicians Lab may charge a sample prep fee 22

Percent recovery, 95% Cl Concentration (µg/kg) 3/8/2016 En Core hold time study samples chilled in field @ 4 C Days Storage Source: En Novative Technologies, Inc. internal research; Dr. David Turriff Stability of VOCs in frozen En Core samples Days Storage Source: En Novative Technologies, Inc. internal research; Dr. David Turriff 23

En Core sampler testing and reliability Quality standards are higher than for sample vials every lot is tested and analyzed for performance and cleanliness Samples of each lot retained for future reference Tested at extreme high and low temperatures Samples can be stored frozen without damage Millions sold without one analytical incident For product information and to watch training videos: www.ennovativetech.com 24

Questions? For technical and sales information, contact: Sarah Conard En Novative Technologies, Inc. Email: sconard@ennovativetech.com Toll Free: 888-411-0757 Outside USA: +1-920-465-3960 25