On-line determination of particle size and concentration (solids and oil) using ViPA Analyser - A way forward to control sub sea separators

Similar documents
Dynamic Imaging Principle OIW/WIO Analysis

Providing clear solutions with innovative design

The Use of Walnut Shell Filtration with Enhanced Synthetic Media for the Reduction and/or Elimination of Upstream Produced Water Treatment Equipment

Enviro Voraxial Technology

Induced Gas Flotation (IGF) within an API Skim Tank A Case Study of Design Approach and Results

Microfil GP. Range. Validation Guide. World Class Filtration Solutions

OIL TECHNOLOGY PORTFOLIO

The World s Most Versatile Filter System

Mott All-Metal Catalyst Recovery Systems High-strength, high-efficiency filtration of particulate

FLOTATION CONTROL & OPTIMISATION

Inland Technologies Inc

Advances in media filtration. Leveraging advanced filtration media with a high oil loading capacity to improve water treatment

Reverse Osmosis, Nano Filtration and Ultra Filtration

AWAS full containerized Pilot Plant

Media Filtration of Produced Water in Polymer Flood Applications

Reverse Osmosis Desalinators

General Guidelines on Drop Size Measurement Techniques and Terminology

ON-LINE OIL TRACE MONITOR

RiOs Essential 5, 8, 16, 24 Water Purification Systems

Manipulating the nature of slurry flows. to overcome production and maintenance challenges. Dr Steve Algie. Consultant, FloCEP Pty Ltd

PREPARED BY: DR. RAHIMAH OTHMAN FOOD ENGINEERING (ERT 426) SEMESTER 1 ACADEMIC SESSION 2016/17

Reverse Osmosis, Nano Filtration and Ultra Filtration

Thermal Imaging for Discharge and Velocity Measurements in Open Channels. PKI 205C, Omaha, NE ;

Modular Oil & Gas Equipment Onshore & Offshore

CEE ENVIRONMENTAL QUALITY ENGINEERING PROBLEM SET #5

Filtration Products. Fluid purifier systems and oil service equipment

SOFI FILTER Self-cleaning microfilter from 1 µm

Betapure CMP Series. CMP Filter Capsules. Superior Reduction Of Large Particle Counts For Improved Yields. Features & Benefits.

Glossary Irrigation Terminology

Automated Methanol dosage using Liquid Flow Controllers: How Nitrogen-Methanol processes for the heat treatment of steel can get more transparent and

Reverse Osmosis, Nano Filtration and Ultra Filtration

Water Solutions in the Oil & Gas Industry Up-stream Water Treatment

HTP. HTP070 Purifier for Dielectric Fluids. PIH HTP070b

Technical Information Paper. (R)FCC Slurry Oil Filtration

NEW ANALYZER FOR VISCOSITY MEASUREMENT AT REFERENCE TEMPERATURE

Onsite FTIR quantitative analysis of water in mineral-based oils using a novel water stabilization technique

Keys to Excellence in the Practice of Process Engineering. An overview by Scott D. Love, P.E. October 2016

INDUSTRIAL FILTRATION EQUIPMENT LWS Filter Series

January 29, This report must be reproduced in full, unless SwRI approves a summary or abridgement.

Problems at the Cumene Production Facility, Unit 800

Proven Solutions for the Most Challenging Wastewaters

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Parker N2-04

PROVISIONAL PATENT APPLICATION NS306. Method for Establishing Self-Lubricated Flow of Bitumen Froth or Heavy Oil in a Pipeline

Amazon FILTRATION SOLUTIONS PHARMACEUTICAL MANUFACTURING

A - CONTACTOR REACTOR SHELL B - TUBE BUNDLE ASSEMBLY C - HYDRAULIC HEAD D - MOTOR E - IMPELLER F - CIRCULATION TUBE

CHEMICAL INJECTION METHODS Pros & Cons

Title Using Neutron Radiography and Liqui. Author(s) Ito, Daisuke; Saito, Yasushi; Kawab. Citation Physics Procedia (2015), 69:

Improved efficiency and lifetime reliability with new hydraulic energy recovery design for CO2 removal in ammonia plants

Intercomparison of Multiphase Flow Facilities: Comparison of NEL and Humble, USA (Texaco)

BÜCHI Labortechnik AG

ON-LINE PRODUCED WATER ANALYSIS FOR OIL AND SOLIDS

SIEMEX OIL SEPARATOR MAINTAINANCE MANUAL SIEMEX OIL SEPARATOR MAINTAINANCE MANUAL. SIEMEX (M) Sdn Bhd

FPSO DEEP TANK SERVICE OVERVIEW, CASE STUDIES AND TESTIMONIALS

FLUID FLOW - PUMPS. Discharge Section. Section. Two main types of pumps: Positive Displacement pumps Centrifugal pumps.

Evaluation Report of

DNVGL-CP-0208 Edition March 2016

ElectroChemTM Advanced EDR

High Efficiency Liquid-Solid Separators

Ribdeck AL STRUX 90/40. efficient designs. with. shallow slabs. fibre reinforced concrete

Industrial Rotary Lobe Pumps. with rubber coated lobes

NEW APPROACH ON FLOTATION TAILINGS DEWATERING

Size quality report for the Zetasizer Nano

Leadership in Filtration. ScandMist Industrial air cleaners

ENGINEERING INFORMATION Hot water and steam service

Performance Evaluation and Cleanability Study using Pellicon 3 Cassettes with 30 kd Biomax and Ultracel Ultrafiltration Membranes

LIQUID CONTROLS. Terminal and Bulk Plant Metering Applications. Application Brochure:

George M. Crawley, Soren Jensen, Al Godek, Andrew P. Malcolmson, Don Holve

Greenhouse Gas Measurement Technology

Chem 321 Lecture 23 - Liquid Chromatography 11/19/13

zahnrad_neu_gb :46 Uhr Seite 1 Gear Pumps

Kinetics of AlH 3 decomposition and subsequent Al oxidation / Hydrogen Jetfires

New filter materials for hydraulic systems: Longer service life and reduced operating costs

Crossflow Filtration for Ink Jet Fluids

PINCH ANALYSIS: For the Efficient Use of Energy, Water & Hydrogen. PULP AND PAPER INDUSTRY Energy Recovery and Effluent Cooling at a TMP Plant

WinGD Integrated Digital Expert WiDE System

MASTERBATCHES. Masterbatch Application and Selection Guide for Irrigation Pipes

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SCP Series Modular Reverse Osmosis System. January 2012 Version

Screening, Definition: The unit involved is called a screen.

Produced Water & Environmental Conference, June 2013

Report AQUA METROLOGY SYSTEMS. SafeGuard H2O Pilot Report. Online Cr(VI) Remediation System

CFD Analysis of Clarifier Performance With and Without Energy Dissipating Inlet

Separation of oil and water

MILLING CONTROL & OPTIMISATION

! TECHNICAL BRIEF OIL-WATER EMULSION BREAKING TECHNOLOGY

PRIMARY GRADE WATER. PURELAB Prima. Primary Grade Water Purification Systems. The Laboratory Water Specialists

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SC Series Modular Reverse Osmosis System. January 2012 Version

Tacolyn resin dispersions

Line Filters Solid, simple, smart. Advanced reliability in compressed air. TECHNOLOGY YOU CAN TRUST

S2 RANGER LE: Analysis of Light Elements in Cement, Slags and Feldspar

Pumps & Systems. Face Unique Challenges with Proven Pumping Solutions NETZSCH Pumps in the Mining Industry

Geothermal Power Plant

MODEL SEM Mill. Two independently adjustable TrueFocus ion sources

WATER RECYCLING PLANT IN WAFRA. Feras Al Salem

Isco EZ TOC. TOC and TC Analysis Made Easy. Continuous on-line TOC/TC measurement using low-temperature oxidation

Proven Flow Measurement Solutions for the Oil and Gas Industry

Fluid Mechanics, Heat Transfer, Thermodynamics. Design Project. Production of Ammonia

Wellhead & Wellstream Desanding Solutions for Offshore Production in Malaysia

5 ppm Bilge Water Separators

INNOVATIVE PLASTIC CONTAINERS

CCSD & CCSE Series Oil/Water Separators

Transcription:

Title On-line determination of particle size and concentration (solids and oil) using ViPA Analyser - A way forward to control sub sea separators Authors Dr. Kami Nezhati, Senior Development Engineer, Merpro Ltd. Nick Roth, Technical Director, Jorin Ltd. Rick Gaskin, Marketing Director, Jorin Ltd. Abstract This paper presents the results of recent development work using Merpro s oily water test loop, an on-line particle size analyser (Jorin s ViPA unit), an industry accepted online oil monitor (Rivertrace unit), and solvent extraction / spectrophotometry technique (Wilk s Infracal unit). The results form these tests showed that the ViPA analyser, not only is capable of measuring oil and solids size distribution in a water continuous stream but also determines their respective concentrations separately by differentiating between each phase dispersed in water. The ViPA analyser was also found to be a useful tool when characterising the oil removal properties of US Filter Liquid / Liquid hydrocyclone and coalescing behaviour of various media. Further development work is currently underway to utilise ViPA analyser as a control device for sub sea separators with a view to a better fluid management and enhance oil production. Objectives One of the aims of this work was to investigate the possibility of using ViPA analyser to establish oil concentration (ppm of oil in water) along with its primary function of measuring oil droplet size distribution. The second aim was to determine deoiling characteristics of US Filter liquid / liquid hydrocyclone separator utilising ViPA image analyser and Rivertrace oil monitor (both on line devices). It was originally hoped to generate a user friendly computer code to predict the hydrocyclone oil removal performance given certain process and physical parameters. The third objective was to establish the oil droplet coalescing properties of various units using ViPA unit on line.

Introduction The ViPA was developed to provide valuable process information such as size distribution and concentration for both oil droplet and solids particles. This together with a knowledge of trend data allows the operators to understand and properly control their unit operations. One of the areas where ViPA unit can be of great benefits is the produced water reinjection systems. For instance, it could be scenarios where the oil concentration is well within the acceptable injection level, but the oil droplet size is large and could cause injectivity problems. It seems there is not any compact and robust particle size and concentration monitor in the market for sub sea application. Therefore, it transpired that an instrument such as ViPA could be integrated as part of the topside and sub sea separator control system to manage and enhance oil production. Test Loop An oily water test loop was constructed in Merpro s pilot plant facilities. The test loop was purpose built to take on-line representative oily water samples from the process flow lines. The test loop was designed in the recycle mode in order to minimise cleaning up of large volumes of oily water and conduct the test runs indefinitely. Most of the injected oil was separated and directed to the oily water tank, whilst the trace of oil left in the process stream was removed from the water using two cartridge filters (in series) before recycling back to the clean water feed tank. A simplified schematics of the oily water test loop is shown in Figure 1. Figure 1 : Schematics of the oily water test loop

It should be noted that fresh water was the main constituent of the oily water used for all the tests and not produced oily water. As a result, the physical properties of the oily water generated in this work was somewhat different to the produced oily water (i.e. water salinity, density, viscosity e t c ). Having said this, all the correct physical parameters were used in our empirical method to predict oil removal characteristics. The oil was dosed into the process line at the discharge of the feed pump at predetermined dosing rates using a small diaphragm pump having a variable speed drive. An immersion heater was installed inside the clean water tank. This enabled us to vary the hydrocyclone feed water temperature from ambient ~10 C to 30-40 C. A shear valve (diaphragm type) was installed downstream of the main feed pump and the oil injection point. By throttling this valve, different oil droplet sizes were generated. This type of valve is known to produce repeatable oil droplet size distribution. This repeatability was also proved during these tests. Two Ametek deoiling cartridge filters were installed in series on the hydrocyclone underflow to remove most of the oil before returning filtered de oiled water to the clean water tank. Instrumentation 1. ViPA analyser The ViPA, Visual Process Analyser, is an on-line instrument for the monitoring of particle and droplet sizes and concentrations. The ViPA can operate continuously online at high pressure and elevated temperatures. The ViPA package consists of the ViPA software set and a compact and robust measuring head (with a built-in cleaning mechanism) that can be located up to 100m from the control computer. Using image analysis techniques to differentiate between particles and droplets in real time, the ViPA can report from up to seventeen parameters continuously including size and concentration. The ViPA software includes a set of trend algorithms that allow process conditions to be predicted, enabling operators to prevent problems occurring.

Figure 2: The ViPA general arrangement The ViPA uses a video microscope assembly consisting of a video camera and lens and a light source to examine the contents of a liquid, see Figure 2. The liquid to be examined passes through the ViPA s cell module, which has a pair of transparent windows, and the camera looks through the liquid at the light source. This allows the video microscope a backlit view of the objects in the liquid flow, whether these are solid particles, liquid droplets or gas bubbles. The ViPA operates by freezing a single frame of the video image and analysing the objects present. A database of information is built by rapidly acquiring and analysing sequences of these frozen images (approx. 20 frames per second regardless of the number of objects per frame).

Figure 3 : A Typical Image as Seen By the ViPA Figure 3 is the image of ground garnet mixed with a light lubricating oil. The individual garnet crystals are approximately 35µm in size. The Jorin ViPA was used primarily to measure oil droplet size distribution in the process line. The on-line mode of this unit ensured representative samples of oily water were measured at operating pressures without any undue shear on the oil droplets exerted usually by a pressure reducing valve. 2. Rivertrace oil monitor A Rivertrace oil in water analyser was used to measure oil concentration on-line. The principle of measurement is known as the scattered light technique. Light beams of specific wavelength, are projected through the wall of the glass measurement cell containing the moving conditioned sample. The intensity of the light received on the other side of the cell, at selected angles, is dependent upon the type of oil, and presence of solids. 3. Infracal analyser The Infracal analyser makes use of the fact that hydrocarbons such as oil can be extracted from water through the use of a suitable solvent and solvent extraction procedure. The extracted hydrocarbons absorb infrared energy at a specific wavelength and the amount of energy absorbed is proportional to the concentration of the oil in the solvent. This method is the industry certified method to monitor the hydrocarbon content in the produced water. Results a. Oil concentration validation (ppm of oil in water) An extensive test program was carried out by Merpro and Jorin engineers to substantiate the oil content capability of the ViPA unit. Forties crude oil was injected upstream of the oily water test loop shear valve (see Figure 1). The Rivertrace oil monitor was utilised for all the runs to measure oil content on-line (0-200 ppm of oil in water). The solvent extraction / IR spectrophotometry was used for selected runs to validate oil content measurement. The test program was set out to investigate the effect of oil concentration variation (100 and 200 ppm) and effect of shear across the globe valve (0 to 5 bar pressure drop) at various water temperatures (ambient to 30 C). The ViPA reports concentration as visible parts per million (ppmv). There is a known volume of liquid for each frame that the ViPA analyses. This volume is calculated as: (the width of the analysed image) x (the height of the analysed image) x (the depth of focus of the image). In each frame the ViPA calculates the volume of the objects for each particle or droplet population/class. At the end of each analysis the ViPA software

software sums up the volume of all the objects in a population/class and the volume of all the frames, which then allows ViPA to report a volume/volume concentration for each run. The measured concentration is reported as visible ppm, because only those objects seen are measured and included in the calculation. In other words, materials passing through the cell between frames and objects that are not in focus are not seen and hence not measured. However, while the concentration figures are not absolute, they are repeatable and indicate how the concentration of a material is changing relative to previous or later measurements. It rapidly transpired that a strong correlation can be found between the oil content values measured using ViPA and Rivertrace oil monitor. It basically means with the increase in oil concentration the ViPA s oil concentration values were also increased. However, this relationship as can be clearly seen in Figure 4, is a strong function of median oil droplet sizes generated during the test program. ViPA oil content (ppm) 400 360 320 280 240 200 160 120 80 ViPA Oil conc calibration Forties crude in fresh water - tests at temperatures 21-30 C Median oil droplet size based on volume distribution Median oil droplet size (µm) 22 to 24 µm 25 to 27 µm 34 to 37 µm 78 to 84 µm 40 0 0 20 40 60 80 100 120 140 160 180 Rivertrace oil content (ppm) Figure 4 : ViPA vs. Rivertrace oil concentration The K factor (the ratio of ViPA to Rivertrace oil content) seems to be increasing with increase in median oil droplet size, see Figure 5. It should be highlighted that unlike ViPA unit, the Rivertrace oil monitor requires conditioning and homogenising the oily water samples prior to directing the sample to the measurement cell. The sample conditioning system basically shear the oil droplets to sizes below say 20 microns which facilitates the oil content measurement.

3.0 ViPA Oil conc calibration Forties crude in fresh water - tests at temperatures 15-30 C Median oil droplet size based on volume distributione K - Ratio of ViPA to Rivertrace oil content 2.5 2.0 1.5 1.0 0.5 0.0 0 10 20 30 40 50 60 70 80 90 100 Median Oil Droplet Size (µm) Figure 5 : ViPA vs. Rivertrace K - Factor A limited number of runs was also conducted using IR / solvent extraction method instead of Rivertrace oil monitor. These runs were only carried out at a fixed pressure drop across the shear valve. Again, similar correlation were found which validated the findings as for Figures 4 and 5. Figure 6 shows the oil concentration readings for IR and ViPA units. ViPA oil content (ppm) 400 360 320 280 240 200 160 120 80 40 0 ViPA Oil conc calibration Forties crude in fresh water - tests at temperatures 21-30 C Median oil droplet size based on volume distribution Median oil droplet size 74 to 84 µm 0 20 40 60 80 100 120 140 160 Infracal oil content - solvent extraction (ppm) Figure 6 : ViPA vs. IR / solvent extraction concentration

This means that the ViPA software can be easily modified to correct the measured oil content following determination of the median oil droplet size. The ViPA software will be upgraded to incorporate the findings of this work. The K-factor, as indicated in figure 5 or 6, will be used to modify the concentration values (note: visible ppm ) from the ViPA to take into account the effect of the median size on reported concentration. This calculated concentration value will be reported in addition to the existing visible ppm. b. deoiling characterisation of US Filter Liquid / Liquid hydrocyclone A migration probability curve, (see Figure 7), was successfully fitted for all the experimental data using an exponential type function similar to Coleman and Thew s 1. However, the newly derived coefficient and exponent were somewhat different to Coleman and Thew s 1. The two main differences between this and Coleman and Thew s work are a different type of hydrocyclone and the sampling method, on-line non-intrusive sampling was used for these tests. REDUCED MIGRATION PROBABILITY CURVE US Filter TL 1.05 Field Test Hydrocyclone Feed Flow = 2600 l/h, PDR = 1.7, Feed Oil content = 100 & 200 ppm Operating Temperature = 7-30 C, Forties crude and Diesel oil injected 1.0 0.9 0.8 Migration probability, MP' (%) 0.7 0.6 0.5 0.4 0.3 0.2 MP'(d) = 1.0 - exp(-2.02( 75-0.506) 0.512 ) 0.1 0.0 0 2 4 6 8 10 12 14 16 18 20 Normalised diameter, 75 (-) Normalised diameter, 75 (-) is the ratio of oil droplet diameter to the separation diameter d' 75 Figure 7 : Migration probability curve for US Filter deoiling hydrocyclone The Jorin ViPA size analyser proved to be an excellent tool to accurately characterise hydrocyclone separation performance in a very short time.

A new dimensional analysis method was developed to fit the separation diameter parameter with the hydraulic information as Coleman and Thew s work method was unable to derive a useful curve for incorporation in our oil separation prediction software. See Figure 8 showing the new dimensional groups and the curve which successfully fitted all the data points. SEPARATION DIAMETER AGAINST DIMENSIONAL HYDROCYCLONE GROUP US Filter TL 1.05 Field Test Hydrocyclone Feed Flow = 1600-2600 l/h, PDR = 1.7, Feed Oil content = 100 & 200 ppm Operating Temperature = 7-30 C, Forties crude and Diesel oil injected 50 Separation diameter, d'75 (µm) 10 5 1 10 6 5x10 6 10 7 5x10 7 10 8 Dimensional hydrocyclone group, Hy 75 /d'75 2 (/m 2 ) Merpro data Coleman & Thew Figure 8 : Hydrocyclone dimensional group for the US Filter deoiling hydrocyclone

INPUT PARAMETERS Operating Water Temperature 55 Hydrocyclone Feed Pressure (gauge) 7 Oil Density at 25 C 930 Available pressure drop across Hydrocyclone 60 C bar kg/m³ psi Hydrocyclone Feed Oil Concentration (Design) 600 ppm Hydrocyclone Outlet Oil Concentration (Design) 40 ppm FEED OIL DROPLET SIZE DISTRIBUTION DATA Oil Droplet Feed cum. Oil Droplet Feed cum. Oil Droplet Feed cum. Oil Droplet Feed cum. diameter undersize diameter undersize diameter undersize diameter undersize µm (%) µm (%) µm (%) µm (%) 3.7 0.0 33.7 40.0 63.7 95.0 93.7 100.0 8.7 10.0 38.7 50.0 68.7 98.0 98.7 100.0 13.7 15.0 43.7 60.0 73.7 99.0 103.7 100.0 18.7 20.0 48.7 70.0 78.7 100.0 108.7 100.0 23.7 25.0 53.7 80.0 83.7 100.0 113.7 100.0 28.7 30.0 58.7 90.0 88.7 100.0 118.7 100.0 100 Migration Probability Migration Probability (%) 80 60 40 20 0 0 20 40 60 80 100 Size (µm) SUMMARY OF RESULTS Oil Separation Efficiency- (design) 93.3 % Oil Separation Efficiency - (prediction) 92.0 % Hydrocyclone Outlet Oil Concentration - (prediction) 48.2 ppm Hydrocyclone Diameter - Fixed for TL 1.05 hydrocyclone 0.019 m CALCULATION Pressure Factor 1.01 - Viscosity of Water at Operating Temperature and Atm. Pressure 0.56 cp Viscosity of Water at Operating Temperature and Pressure 0.00056 kg/m.s Oil Density at Operating Temperature and Pressure 912.1 kg/m 3 Water Density at Operating Temperature 985.8 kg/m 3 Oil and Water Density Difference at Operating Temperature and Pressure 73.7 kg/m 3 Hydrocyclone Feed Flowrate 4.9 m³/h Dimensional Hydrocyclone Group 25842077 - d' 75, Oil Droplet Diameter at MP' = 75% 7.4 µm Figure 9 : A print - out of the oil removal prediction program (US Filter hydrocyclone) Figure 9 shows a print out of the computer software (relevant page) written to predict the outlet oil concentration given certain feed process parameters. This software utilises the findings mentioned above (e.g. Figures 7 and 8) and other process

calculations to derive the required oil separation efficiency, feed flowrate and separation diameter (d 75 ). Future - utilisation of ViPA to improve produced water treatment One of the important areas in which ViPA unit can be installed to improve the produced water quality is on the feed and clean streams of the deoiling hydrocyclone packages. The oil droplet size and oil content data from these streams can be monitored on-line. These information should enable the operator to make rapid judgement and appropriate adjustment to the deoiling hydrocyclone control to maintain the optimum hydrocyclone separation efficiency. As highlighted earlier in this paper and mentioned elsewhere, the oil droplet size has a significant impact on the deoiling performance of the hydrocyclone and consequently its discharge quality (ppm of oil). Other advantage of the ViPA unit is that gas bubbles and oil droplets can be distinguished (in some cases) due to their characteristics (Jorin future development). Obviously, solids and gas can be detrimental to the hydrocyclone performance. Again, these data can be utilised by the operator to make corrective and rapid actions upstream of the hydrocyclones to minimise solids and gas content. The other area of great interest, is to use the ViPA unit as a produced water quality controller on the TORE SEP / hydrocyclone package (for more information see paper entitled Efficient Compact Centrifugal Separation Utilising Merpro s TORE SEP Technology ) or any other FWKO units which has a low residence. This simply means the ViPA unit will measure the oil content of the oily water discharge from this package and send appropriate signals to control an automated valve situated downstream of the hydrocyclone to ensure the discharge of oily water remains within the required level. This method has the potential of replacing the problematic liquid level control system on the 3 phase separators. Once this technology is proven on topside oil and gas platforms, it can be easily transferred to control sub sea separators. ViPA can also be used as a tool to monitor and control the injection of chemicals responsible for oil droplet growth. These chemicals are commonly injected to enhance oil removal efficiency of the deoiling hydrocyclones. The chemical dosing rate could be optimised by continuously measuring oil droplet size distribution to ensure a suitable oil droplet growth and hence achieving the required discharge water quality. The ViPA utilisation will undoubtedly optimise (in some cases minimise) the usage of these chemicals which is not only beneficial as The other potential area could be minimising the usage of solvent during IR / solvent extraction technique to measure the oil content of the discharge water. The ViPA unit can monitor the overboard discharge water wastes, not only to measure the oil droplet size distribution but monitoring and measuring the oil content of the discharged stream. The ViPA unit can determine the ppm of oil after very short intervals (say 5-10 minutes) instead of the routine 12 hourly measurement using IR / solvent extraction. This should lessen the amount of solvent used offshore and also extends the knowledge

the knowledge of the oil concentration and droplet size data which should pave the way for a rapid reparation response to the plant operation in general. References 1. Coleman and Thew, Correlation of separation results from light dispersion hydrocyclones, Chem. Eng. Res. Des., Vol. 6, July 1983.