Product Guide Specification

Similar documents
PRODUCT GUIDE SPECIFICATION

SECTION Structured Polycarbonate Panel Assemblies. Series 3500 BPC System with 40mm Tongue and Groove

Guide Specification SECTION QUARTZ AGGLOMERATE COUNTERTOPS

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

Alply CLASSIC WALL Architectural Insulated Panel Wall System

SPECIFICATION GUIDELINE

Product Guide Specification

SL150 Guide Specification

TerraClad TM General Specifications

A. ASTM C190 - Test Method for Tensile Strength of Hydraulic Cement Mortars

Corium Brick Rainscreen System Specifications

Guideline Specifications

Product Guide Specification

PRODUCT SPECIFICATIONS

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

HPL CSI 3-PART SPECIFICATION FORM


Signature Series 5 Lap SECTION ALUMINUM WINDOWS

Page 1 of 5

Product Guide Specification

Product Guide Specification

SECTION METAL COMPOSITE MATERIAL WALL PANELS

NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION. MASTERFORMAT SECTION (Mortarless Concrete Brick Veneer)

SECTION COPPER WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.***

SECTION INSULATED METAL WALL PANELS. ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications

SECTION EXPANSION CONTROL

Valspar InspireME Coil and Extrusion Product Guide Specification Section Shop-Applied Coatings for Metal

SECTION FIBERGLASS REINFORCED POLYMER (FRP) PANELS

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

BEARING METAL STUD FRAMING

ACOUSTICAL WALL TREATMENT SECTION 09840

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

Eco Deco Building System

SECTION WINDOW FILM. A. Section Windows; windows to receive architectural window film.

B. Samples for Initial Selection: For each type of impact-resistant wall protection unit indicated.

FRP Floor Panels Standard Specification

PROJECT LOCATION SECTION TEXTURED METAL PLATE WALL PANELS

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

1.1 SECTION INCLUDES A. Insulated Metal and FRP Wall and Ceiling Panels and Related Accessories.

ESR ICC Evaluation Service, Inc. Issued November 1, 2003 This report is subject to re-examination in one year.

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

FRP Specifications. Section Fiberglass Reinforced Polymer (FRP) Baffle Wall Panel Products and Fabrications REVISED 11.

CENTRIA FORMABOND II Metal Composite Wall System

Specifications for FL-100 Soffit Panel

SECTION TOILET COMPARTMENTS. A. Section Metal Fabrications: Concealed steel support members.

CENTRIA Intercept Entyre Preformed Metal Modular Panel Wall System

PROJECT LOCATION SECTION ZINC ALLOY METAL PLATE WALL PANELS

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

SECTION PRECAST CONCRETE PAVERS AND PEDESTAL LOK DOWN SYSTEM

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

EDGEWATER, FLORIDA JUNE 14, 2010

A. This Section includes automatic entrance door systems operating as follows: 1. Swinging operation.

SECTION MANUFACTURED ROOF EXPANSION JOINTS

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

SECTION CONCRETE PAVING SLABS SET IN MORTAR

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM

Gold Bond BRAND Gypsum Sheathing

SECTION TURBINE VENTILATORS

Architectural Specifications, Section Phenolic Lockers

PW251 21/2 x7 GUIDE SPECIFICATION. Curtain Wall

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

Magnum Board Section Digicon Information Inc. Page 1

VITRABOND Aluminum Composite Panel Façade System Specification Template

SECTION CRC575 UNITARY CLEANROOM WALL SYSTEM STUDLESS CLEANROOMWALL SYSTEM ME175 3-IN-1 CLEANROOM WALL SYSTEM

CTP STITCH-TIE AGAIN! Quick and easy way to re-anchor existing veneers to back-up structures.

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS

ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES FIBERGRATE MOLDED GRATING WITH GRATING PEDESTALS. January 24,

SECTION LINEAR WOOD CEILINGS

SECTION CLIMBING WALLS

Section QUARTZ SURFACING COUNTERTOPS

Section Domestic Water Piping (Hot and Cold Water Potable Water Distribution)

ANSI/APA PRS Standard for Performance-Rated Structural Insulated Panels in Wall Applications

SECTION Summit Phenolic Lockers (Solid Phenolic Lockers)

ACCEPTANCE CRITERIA FOR METAL COMPOSITE MATERIAL (MCM) PREFACE

SECTION and/or Resilient Sheet Flooring and/or Resilient Tile Flooring

SECTION IMPACT RESISTANT WALL PROTECTION

EVO ALUMINUM COMPOSITE METAL (ACM) WALL PANEL SPECIFICATION

FRP Specifications. Section Fiberglass Reinforced Polymer (FRP) Pultruded Grating/Treads and Fabrications REVISED

Section HIGH-TENSION Stretched-Fabric Wall Systems SoftWalls, Inc.

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

FRP Specifications. Section Fiberglass Reinforced Polymer (FRP) Structural Shapes/Plate and Fabrications REVISED

CSI GUIDE Countertops

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

GUIDE SPECIFICATION

A. Access doors and frames are part of an access door and frame allowance.

SECTION VINYL ACRYLIC CLAD WOOD DOORS PART 1 GENERAL 1.1 RELATED DOCUMENTS

SECTION STAY-IN-PLACE INSULATED CONCRETE FORMING SYSTEM

Specification for larson by Alucoil PE Core Aluminum Composite Material (ACM)

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

Guide Specifications for Prodema PRODEX External Cladding

ARCHITECTURAL TESTING, Inc. Code Compliance Research Report #0774 CCRR-0131

(Specifier Note: Aristech Surfaces LLC is the manufacturer of the Avonite brand

SECTION Solar Control Film WINDOW FILM. Copyright ARCAT, Inc. - All rights reserved

PER See all Pei ES Listings at:

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

SIMEILINGS TORSION SPRING CEILING SYSTEM SPECIFICATION

Transcription:

April 2014 6840 SW 81 Terrace Miami, Florida 33143 Phone 305-666-6676 Fax 305-666-7675 Website www.trimstonepanels.com E-mail stoneworks@stoneworksofart.com Product Guide Specification Specifier Notes: This product guide specification is written according to the Construction Specifications Institute (CSI) 3-Part Format, including MasterFormat, SectionFormat, and PageFormat, as described in The CSI Construction Specifications Practice Guide. This section must be carefully reviewed and edited by the Architect to meet the requirements of the project and local building code. Coordinate this section with other specification sections and the Drawings. Delete all Specifier Notes after editing this section. Section numbers and titles are from MasterFormat 2012 Update. SECTION 04 42 00 EXTERIOR STONE CLADDING Specifier Notes: This section covers Trimstone exterior, factory-fabricated, lightweight, stone paneling system, composed of natural stone veneer bonded to high-strength, aviation-grade, aluminum honeycomb panels. Each lightweight stone paneling system is custom designed by for the specific application. Consult for assistance in editing this section for the specific application. PART 1 GENERAL 1.1 SECTION INCLUDES A. Exterior, factory-fabricated, lightweight, stone paneling system. Stone Paneling System 04 42 00-1

1.2 RELATED REQUIREMENTS Specifier Notes: Edit the following list of related sections as necessary. Limit the list to sections with specific information that the reader might expect to find in this section, but is specified elsewhere. A. Section 07 92 00 Joint Sealants. 1.3 REFERENCE STANDARDS Specifier Notes: List reference standards used elsewhere in this section, complete with designations and titles. A. ASTM B 117 Standard Practice for Operating Salt Spray (Fog) Apparatus. B. ASTM C 67 Standard Test Methods for Sampling and Testing Brick and Structural Clay Tile. C. ASTM C 297 / C 297M Standard Test Method for Flatwise Tensile Strength of Sandwich Constructions. D. ASTM C 365 / C 365M Standard Test Method for Flatwise Compressive Properties of Sandwich Cores. E. ASTM C 393 / C 393M Standard Test Method for Core Shear Properties of Sandwich Constructions by Beam Flexure. F. ASTM D 1761 Standard Test Methods for Mechanical Fasteners in Wood. G. ASTM D 1781 Standard Test Method for Climbing Drum Peel for Adhesives. H. ASTM E 72 Standard Test Methods of Conducting Strength Tests of Panels for Building Construction. I. ASTM E 84 Standard Test Method for Surface Burning Characteristics of Building Materials. J. ASTM E 108 Standard Test Methods for Fire Tests of Roof Coverings. K. ASTME E 1886-13a - Standard Test Method for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials L. ASTM E 1996-14a - Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Windborne Debris in Hurricanes M. FBC TAS 201 Impact Test Procedures N. FBC TAS 202 Criteria for Testing Impact & Non-Impact Resistance Building Envelope Components Using Uniform Static Air Pressure Stone Paneling System 04 42 00-2

O. FBC TAS 203 Criteria for Testing Products Subject to Cyclic Wind Pressure P. Marble Institute of America (MIA) Dimension Stone Design Manual. Q. NFPA 255 Standard Method of Test of Surface Burning Characteristics of Building Materials. R. NFPA 259 Standard Test Method for Potential Heat of Building Materials. S. UBC 8-1 Test Method for Surface-Burning Characteristics of Building Materials. T. UL 723 Test for Surface Burning Characteristics of Building Materials. U. UL 790 Standard Test Methods for Fire Tests of Roof Coverings. 1.4 PREINSTALLATION MEETINGS Specifier Notes: Edit pre-installation meetings as necessary. Delete if not required. A. Convene pre-installation meeting [1 week] [2 weeks] before start of installation of lightweight stone paneling system. B. Require attendance of parties directly affecting work of this section, including Contractor, Architect, installer, and manufacturer s representative. C. Review materials, installation, adjusting, cleaning, protection, and coordination with other work. 1.5 SUBMITTALS Specifier Notes: Edit submittal requirements as necessary. Delete submittals not required. A. Comply with Section 01 33 00 Submittal Procedures. B. Product Data: Submit manufacturer s product data, including installation instructions. C. Shop Drawings: Submit manufacturer s shop drawings, including plans, elevations, sections, and details, indicating dimensions, tolerances, materials, components, fabrication, fasteners, hardware, and finish. D. Samples: Submit manufacturer s sample of lightweight stone paneling system. 1. Sample Size: Minimum 12 inches by 12 inches. E. Manufacturer s Certification: Submit manufacturer s certification that materials comply with specified requirements and are suitable for intended application. F. Test Reports: Submit manufacturer s test reports from testing performed by qualified, independent testing laboratories. Stone Paneling System 04 42 00-3

G. Manufacturer s Project References: Submit manufacturer s list of successfully completed lightweight stone paneling system projects, including project name and location, name of architect, and type and quantity of lightweight stone paneling systems furnished. H. Installer s Project References: Submit installer s list of successfully completed lightweight stone paneling system projects, including project name and location, name of architect, and type and quantity of lightweight stone paneling systems installed. I. Cleaning Instructions: Submit manufacturer s cleaning instructions. J. Warranty Documentation: Submit manufacturer s standard warranty. 1.6 QUALITY ASSURANCE A. Manufacturer s Qualifications: 1. Manufacturer regularly engaged, for past 10 years, in the manufacturing of lightweight stone paneling systems of similar type to that specified. 2. Available to provide manufacturer s representative during installation of lightweight stone paneling system. B. Installer's Qualifications: 1. Installer regularly engaged, for past 5 years, in installation of lightweight stone paneling systems of similar type to that specified. 2. Employ persons trained for installation of lightweight stone paneling systems. 3. Approved by manufacturer. Specifier Notes: Edit mock-ups as necessary. Delete if not required. C. Mock-ups: Construct mock-ups of lightweight stone paneling system for evaluation of factory fabrication and installation. 1. Construct mock-ups using same materials for use in the Work. 2. Install mock-ups at locations determined by Architect. 3. Do not proceed until factory fabrication and installation of mock-ups are approved by Architect. 4. Approved Mock-ups: Standard for factory fabrication and installation of lightweight stone paneling system. 1.7 DELIVERY, STORAGE, AND HANDLING A. Delivery Requirements: Deliver materials to site in manufacturer s original, unopened containers and packaging, with labels clearly identifying product name and manufacturer. B. Storage and Handling Requirements: 1. Store and handle materials in accordance with manufacturer s instructions. 2. Keep panels in manufacturer s original crates and packaging until installation. 3. Store panels in clean, dry area. 4. Store and handle panels vertically to prevent bending, warping, or damage. 5. Do not stack panels. Stone Paneling System 04 42 00-4

6. Protect panels and finish during storage, handling, and installation to prevent damage, scratches, and stains. 1.8 WARRANTY A. Warranty Period: 10 years from date of Substantial Completion for delamination of panel components. PART 2 PRODUCTS 2.1 MANUFACTURER A. Manufacturer:, 6840 SW 81 Terrace, Miami, Florida 33143. Phone 305-666- 6676. Fax 305-666-7675. Website www.trimstonepanels.com. E-mail stoneworks@stoneworksofart.com. B. Substitutions: Not permitted. 2.2 TEST RESULTS A. Lightweight Stone Paneling System: Trimstone. 1. Transverse Load Test, ASTM E 72: a. Deflection at 215 psf: 0.49 inch. b. Ultimate Load: 630 psf. 2. Surface Burning Characteristics, ASTM E 84 (NFPA 255, UBC 8-1, UL 723): a. Flame Spread Rated: Class A. b. Smoke Developed Rated: Class A. 3. Fire Test, ASTM E 108 (UL 790), Acceptance Level: Class A. 4. Flatwise Strength Test, ASTM C 297, Average Ultimate Strength: a. As Received: 437 psi. Failure occurred within the stone (limestone). b. After 100 Cycles of Freeze-Thaw, ASTM C 67: 415 psi. Failure occurred within the stone (limestone). 5. Potential Heat, NFPA 259: 830.9741 Btu/lb 6. FBC TAS 201,202,203 passed with a 120 PSF Positive / Negative Pressure B. Honeycomb Panels: Plascore, Inc. AA5.2-95. 1. Salt Spray Exposure Test, ASTM B 117, 30 days: Passes without weight loss greater than 125 mg per sq ft of exposed foil area. 2. Flatwise Tensile Strength Test, ASTM C 297: 998 psi (6.88 N/mm 2 ). 3. Climbing Drum Test, ASTM D 1781: 92 lbf (407 N). 4. Stabilized Compressive Strength Test, ASTM C 365: 749 psi (5.16 N/mm 2 ). 5. Flexural Rigidity Test, ASTM C 393: 17,776 lb-in 2 (4.83 N-mm 2 ). 6. Peak Load, 1-inch-thick panel: 360 lbs (1.60 kn). C. T-Nut Threaded Inserts: Stone Paneling System 04 42 00-5

1. Diameter: 5/16 inch. 2. Fastener Pullout Capacity, ASTM D 1761: 1,955 lbs. 2.3 LIGHTWEIGHT STONE PANELING SYSTEM Specifier Notes: Each lightweight stone paneling system is custom designed by for the specific application. A. Lightweight Stone Paneling System: Trimstone. 1. Description: Exterior, factory-fabricated, lightweight, stone paneling system, composed of natural stone veneer bonded by 2-part, high-strength, epoxy resin to high-strength, aviation-grade, aluminum honeycomb panels. Specifier Notes: Specify total panel unit weight and thickness. 2. Total Panel Unit Weight: psf. 3. Total Panel Thickness: inch, plus or minus 1/16 inch. Specifier Notes: Stone may be supplied by either or by the Owner. Consult for information regarding stone type, source, color, thickness, hardness, and finish required for the specific application. B. Stone: 1. Type: [Marble] [Granite] [Limestone] [Travertine] [Onyx] [ ]. 2. Source:. 3. Color:. 4. Thickness: [3/16 inch] [ inch], plus or minus 1/16 inch. 5. Hardness, MOHS Scale:. 6. Edges: Indicated on the Drawings. 7. Finish: [Polished] [Honed] [ ]. Specifier Notes: Consult for information regarding honeycomb panels required for the specific application. C. Honeycomb Panels: 1. Material: Plascore, Inc. AA5.2-95 honeycomb panels. a. Aluminum Alloy 3003. 2. Bonded with epoxy to back of stone. 3. Average Weight: Approximately 0.75 psf. 4. Thickness: 3/4 inch, plus or minus 0.02 inch. 5. Honeycomb Structure: Corrosion-protected, 1/4-inch-cell aluminum core. 6. Fiberglass Skins: Woven 0.018-inch fiberglass skin with flame-retardant epoxy resin. Stone Paneling System 04 42 00-6

Specifier Notes: Consult for information regarding interlocking channel brackets required for the specific application. D. Interlocking Channel Brackets: 1. Material: Aluminum extrusion, Alloy 6063-T6. 2. Factory installed on back of honeycomb panels with: a. T-Nut Threaded Inserts: Set in epoxy. b. Truss-head screws. c. Nylon washers. 2.4 ACCESSORIES A. Joint Sealants: 1. Specified in Section 07 92 00. 2. Compatible with lightweight stone paneling system. 3. Backer rods. PART 3 EXECUTION 3.1 EXAMINATION A. Examine surfaces and areas to receive lightweight stone paneling system. Specifier Notes: Edit the following sentence for the specific application. B. Verify surfaces to support lightweight stone paneling system are clean, dry, flat, plumb, level, square, stable, rigid, of proper dimensions, and capable of supporting the weight. C. Notify Architect of conditions that would adversely affect installation or subsequent use. D. Do not begin installation until unacceptable conditions are corrected. E. Field Measurements: 1. Verify actual measurements and openings by field measurements before factory fabrication. 2. Confirm recorded measurements on shop drawings. 3. Coordinate field measurements and factory fabrication schedule with construction progress to avoid construction delays. 3.2 INSTALLATION A. Install lightweight stone paneling system in accordance with manufacturer s instructions at locations indicated on the Drawings. B. Install lightweight stone paneling system plumb, level, square, and true to line. Stone Paneling System 04 42 00-7

C. Anchor lightweight stone paneling system securely in place to supports. D. Install lightweight stone paneling system weathertight. E. Tolerances: Install lightweight stone paneling system within manufacturer s installation tolerances. F. Dissimilar Materials: Provide separation of aluminum materials from sources of corrosion or electrolytic action contact points. G. Joint Sealants: Apply joint sealants and backer rods as specified in Section 07 92 00. 3.3 ADJUSTING A. Repair minor damages to lightweight stone paneling system in accordance with manufacturer s instructions, MIA Dimension Stone Design Manual, and as approved by Architect. B. Remove and replace with new material, damaged components that cannot be successfully repaired, as determined by Architect. 3.4 CLEANING A. Clean lightweight stone paneling system promptly after installation in accordance with manufacturer s instructions. B. Do not use harsh cleaning materials or methods that could damage panels or finish. 3.5 PROTECTION A. Protect installed lightweight stone paneling system to ensure that, except for normal weathering, panels will be without damage or deterioration at time of Substantial Completion. END OF SECTION Stone Paneling System 04 42 00-8