Surge arrester 3EB4. with polymeric composite housing for operating aboard traction units

Similar documents
Technical Specification for LV ABC Fuse Switch Disconnectors

Notes Changed note Date. 1 (A) Changed template 09 / 07 / 2008

Change-over and monitoring unit For medical locations acc. to DIN VDE 0100 Part 710

ENERGY PROTOLON(SMK) LWL. (N)TSKCGEWOEU Medium Voltage Reeling Cable with integrated Fibre Optics

Energy Division Insulators

NTC thermistors for temperature measurement

Technical Specification for Live Line Tap Connectors

Sikaflex 221 is a high-adhesion, polyurethane-based sealing compound for Low-odour

INNOVATIVE LIFE-CYCLE CONCEPTS FOR MEDIUM-VOLTAGE SWITCHGEAR ON BROWN COAL SURFACE MINING DEVICES

Preparation and Installation of the FA, FAV, and FAS Type Rupture Discs in Forward Acting Insert, Full Bolted, and Union Type Holders

ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200

An Insight into Design, Development & Testing of Insulation Piercing Connectors for LV Application

Read and understand this manual for safely usage.

GENERAL CONTENTS SECTION I - NUCLEAR ISLAND COMPONENTS

20 W Power Resistor, Thick Film Technology, TO-220

TRAPEZOIDAL SHEET METAL RAIL

Extended-Frequency SMA Connectors

Documentation. Transient voltage suppressor - AX2090- TS Version: Date:

Resin impregnated paper bushings. Product information

Company Replaces previous document Document ID Issue E.ON Elnät Sverige AB Ny engelsk utgåva D

Weir Valve Selections

PART MATERIAL REMARK Metal Case with Pig-tail. Brass (Metal Case) Copper (Pig-tail) Star Contact Copper Silver Plated

GUJARAT ENERGY TRANSMISSION CORPORATION LTD. TECHNICAL SPECIFICATIONS. 66 kv LIGHTNING ARRESTORS

U.V resistance UL Sunlight Resistance. Flame retardant IEC

SURGE ARRESTERS kv in silicone shield

Operating Instructions

Lightning Protection Practice for Large-Extended Photovoltaic Installations

Rosemount 1152 Alphaline Nuclear Pressure Transmitter

ON-ROOF ATTACHMENT FLAT COLLECTOR HELIOSTAR

Fixings, bonds and clamps

ARRANGEMENT AND WORKING OF MULTIPORT FLOW SELECTOR VALVE IN PRODUCTION MANIFOLD:

SECTION HIGH EFFICIENCY DISTRIBUTION TRANSFORMERS

Effect Of Oxidation In Tin Coated Copper Bus Connections

Gas-insulated medium-voltage switchgear. for wind parks. Answers for energy.

MASTERSPEC - SHORT FORM. B. See Division 5 Section "Metal Stairs" for steel tube railings associated with metal stairs.

HIGH VOLTAGE INSULATORS. By JP Holtzhausen. Glass. Bushings & hollow core insulators. Cap & pin insulators

Z5028 E3/Ci80 Horizontal bracket Mounting instructions

APEC 2016 Component Level Safety Certification in Systems- IEC /UL1577. MARK CANTRELL Senior Applications Engineer

Aluminium recycling in the window and curtain walling industry

HELIOSTAR 252, 218 HORIZONTAL, FREE INSTALLATION

A 30/36 V BF. coarse medium fi n e soft medium hard. A aluminium oxide M R U BA resin bond

ifix INSTALLATION MANUAL PV flat roof installation system Version

This Installation Guide uses the following symbols to indicate important information. Always observe the instructions indicated by these symbols.

PMA 31-G. English. Printed: Doc-Nr: PUB / / 000 / 00

Glass Reinforced Polyester Enclosures BPG. Glass Reinforced Polyester Enclosures

Service Entrance Cable Fittings

Z5033 E3 Ball joint adapter Mounting instructions

Power Resistor for Mounting onto a Heatsink Thick Film Technology

Drag Chain Conveyor Installation and Operation Manual

YINGLI SOLAR TWINMAX MODULES Installation and User Manual

User Manual For Clamp H- Beam

A. Product Data shall be provided for each type of product indicated.

Z5010 (Version 2) TV spigot with fixing plate Mounting instructions

Rosemount 1154 Alphaline Nuclear Pressure Transmitter

SPECIFICATION FOR ALL ALUMINIUM ALLOY STRANDED CONDUCTOR

Fire Protection Valves

Mechatronic pressure measurement. Applications. Special features. Description

PRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches.

BUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466

Safety Railing Solutions

Carbon film resistors

HELIOSTAR 252, 218 VERTICAL, FREE INSTALLATION

Underground fire hydrants

SECTION GROUNDING AND BONDING

Understanding New IEC Mechanical Test Requirements of Arresters

MC -SEALconTACT. Multilam contacts. Multilam Technology

Create a reliable future. For over 65 years. Our products As diverse as your ideas. Carbon brushes

Welding Accessories

The complete guide to transformers and packaged substations

Polymer Post Insulators for 46 to 500kV Applications

Safety Barrier Solutions

It s All a Matter of TechNiQ. NiQ: Our latest generation of energy-saving motors.

-L- Pressure bar

Operate Manual. DA-1600i Stud Welding Machine. DA-2000i Stud Welding Machine. DA-2500i Stud Welding Machine

Pins Insulator. Composite/Polymers Insulators


ANSI/ ASME HST Performance Standard For Overhead Electric Wire Rope Hoists

Section ARMORED MEDIUM VOLTAGE CABLES SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR

SPECIFICATION: LINE TAPS FOR ALUMINIUM/ACSR AND COPPER CONDUCTORS

Archimedean screw pumps. Reliable robust tried and tested

SECTION CHAIN-LINK FENCES AND GATES 02821/1

Rack Power Distribution Unit AP7562, AP7563, AP7564 General Information

DISTRIBUTION SILICONE INSULATORS Deadend / Suspension 15 kv to 69 kv

Allround Scaffolding. Layher Allround Bridging System Instructions for Assembly and Use. Modular truss system for wide spans

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

NEUTRAL GROUNDING TRANSFORMERS INSTALLATION AND MAINTENANCE INSTRUCTIONS

Technical instructions. Mini Brio X15CA Underwater LED lighting. Table of Contents. Réf : PK10R303

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

Please take the time to complete the attached questionnaire and return the completed survey within thirty (30) days of receipt.

PITCHED ROOF. Photovoltaic Mounting Systems. Assembly Instructions. for roofing tiles, plain tiles and slate

SCAFFOLDING RUNWAY SYSTEM

Protective Capony RTC-16

Thermocouples and Accessories Product Catalog

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SUGGESTED SPECIFICATIONS Pump Frames through 64132

Galvanic and Stray Current Corrosion

D1 Series Multi-hole Cage Guided Control Valves

Specifications Electrical Metallic Tubing (EMT)

Over pressure Switching pressure difference (typical) Lower range Upper range

Mechatronics Courses by School Period

Transcription:

Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model or design patent are reserved. Surge arrester 3EB4 with polymeric composite housing for operating aboard traction units Operating instructions Siemens Aktiengesellschaft All rights reserved. Siemens AG 03/2008 Order No.: 928 00079 176

Contents Description 3 Technical data 3 Design 3 Mode of operation 4 Transport and storage Fehler! Textmarke nicht definiert. Screwed joints 5 Installation 5 Place of installation 5 Disposal arrester and arrester accessories Fehler! Textmarke nicht definiert. Maintenance 8 The manufacturer of this surge arrester Siemens AG Energy Sector Power Transmission High Voltage has introduced and applies a quality system in accordance with DIN ISO 9001 / EN 29 001 Quality systems: Model for quality assurance This system was first demonstrated in 1989 to the DQS (German Association for the Certification of Quality Systems). The electrical testing laboratories and the materials technology laboratories of the manufacturer have been certified since 1992 by the German Accreditation Body in accordance with DIN EN 45 001. If you require further copies of the operating instructions, please order them from the appropriate Siemens office, indicating the title and order number shown on the title page. Published by: In case of request: Siemens AG Telephone exchange +49 / 30 / 386 1 PTD H 51 Sales department: +49 / 30 / 386 33222 D-13623 Berlin Fax: +49 / 30 / 386 26721 e-mail: mailto:arrester@siemens.de Subject to change. Note The equipment covered by these instructions should be installed and serviced only by competent personnel familiar with good safety practices. This instruction is written for such personnel and is not intended as a substitute for adequate training an experience in safe procedures. This information is intended for the correct installation of this product. Siemens has no control over the condition of the network, which can be greatly affected by the installation of a product. It is the responsibility of the user to chose the appropriate method of installation. Under no circumstance is Siemens liable for any direct or indirect damage caused by the use or misuse of this product. 2 Siemens AG 03/2008

Description The 3EB4 surge arrester serves to protect the insulation of a system (or of one of its components) from undue stresses resulting from overvoltages. It is designed for special operating conditions encountered aboard traction units. Technical data The standard model is suitable for the operation of up to 1800 m above sea-level and for a rated frequency between 16 2/3 Hz and 62 Hz AC (3EB4 xxx-xaxxx-xx) and DC (3EB4 xxx-xdxxx-xx) respectively. The surge arrester meets the following standards as for as applicable: Standard Classification VDE 0675-4 : 2007-04-01 10 ka IEC 60099-4, Ed. 2.1, 2006-07 10 ka IEEE Std C62.11-2005 EN 50123-5/A1:2003-02 (if applicable) VDE 0115 part 1 und part 2 Fig. 1. 3EB4 xxx-xxsxx-xx Surge arrester type 3EB 3EB4 xxx-xxmxx-xx The rating plate [Fig. 2.] is attached to the bottom flange. s Gapless MO-Surge Arrester Type (1) Ur (2) kv Uc (3) kv f (9) Hz In (4) ka LD-CL (5) PR-CL (6) ka Dat. (7)/(8)B IEC 60099-4 MADE IN GERMANY AC surge arrester 3EB4 xxx-xaxxx-xx 1 Order No. 2 Rated voltage 3 Continuos operating voltage 4 Nominal discharge current 5 Long-duration discharge class Fig. 2. Rating plate s Gapless MO-Surge Arrester Type (1) Ur (2) kv DC Uc (3) kv DC Up (10) kv In (4) ka PR-CL (6) ka Dat. (7)/(8)B EN 50123-5 MADE IN GERMANY DC surge arrester 3EB4 xxx-xdxxx-xx 6 Pressure-relief class 7 Year of manufacture 8 Serial No. 9 Frequency (only 3EB4 xxx-xaxxx-xx) 10 Residual voltage at I n (only 3EB4 xxx-xdxxx-xx) Design The active components of the arrester are metal-oxide resistors. They are installed in an airtight sealed polymeric composite housing 1 (tube of fibre-rein-forced plastic with silicone rubber coatings [Fig. 3.]. The housing consists of 2 major components: A fibre-reinforced plastic tube to ensure high mechanical strength. If the arrester is overloaded the tube does not break. This ensures that no parts are thrown off if the arrester fails. Siemens AG 03/2008 3

The hydrophobic properties of the high-temperature cross-linked silicon rubber coating ensure that electrical discharges on the housing surface are kept to a minimum; particularly good operating characteristics are therefore assured even under conditions of pollution. The flanges (provided in some cases with integral gas diverter) are made of a weather-resistant light alloy and are bonded to the polymeric composite housing. UV and ozone resistant sealing rings and corrosion-resistant metal diaphragms ensure perfect sealing for years. The arrester is fitted with a pressure relief diaphragm and a gas diverter at the lower end [Fig. 3.]. In the case of an arrester being overloaded, this pressure relief diaphragm will open at a pressure amounting to a fraction of the polymeric composite housing pressure resistance. Under these circumstances the gas flow is directed onto the arcing horn attached to the upper arrester flange, and so arcing can continue outside the housing until the feeder is switched off. Due to the high permissible bending moment and the excellent mechanical strength of the housing, the arrester type 3EB4 can be simultaneously used as a post insulator in addition to its actual arrester function. The function as a post insulator is not affected by an overload of the arrester. Before it is used as a post insulator, the manufacturer must be consulted to clarify the occurring loads. Mode of operation Metal-oxide resistors are highly non-linear, i.e. they have a sharply kinked voltage-current characteristic, with the result that below a certain voltage value only a small leakage current flows through the arrester. The arresters are so designed that under normal continuous voltage conditions only leakage current of approx. < 1mA flows. With lightning or switching overvoltages, the resistors become conductive (ohm range) so that a surge current can flow to earth and the overvoltage is reduced to the value of the voltage drop across the arrester (residual voltage). The surge currents have values of up to 500 A with switching overvoltages, and of 1... 5... 10 ka with lightning overvoltages. 1 Polymeric composite housing 2 Flange with gas diverter 4 Non-linear metal-oxide resistor 5 Intermediate plate 6 Drain hole Fig. 3. Sectional view Transport and storage The arresters are packed according to the stresses and climatic conditions during transportation and to the customer s specifications. The packing is provided with signs for transport and storage as well as directives for appropriate handling. As soon as the shipment arrives examine it for signs of damage. If such damage be found immediately notify the forwarding agent. Any parts packed separately should be checked against the dispatch notes. All the boxes should be opened for this purpose. 4 Siemens AG 03/2008

With long storage it is recommended to leave the units and the accessories in the transport packing. Screwed joints Grease the bolt threads with Molykote Longterm 2 plus. Attention Unchecked tightening can result in damage to or loosing of bolt joints. Use torque wrench for assembly. Necessary torque for screwed joints: Installation M 10: M 12: 35 ± 4 Nm 45 ± 6 Nm Important note: Note the following before installing Warning Before any work starts: switch off and isolate secure against reclosing verify that equipment is dead earth and short circuit the equipment cover or fence off nearby live parts Death, severe injury and considerable damage to property and environmental damage may result if the safety instructions are not followed. Confirm that these safety measures have been carried out. Accessories With the standard model, the following accessories are included in the scope of supply: Connecting lug for earth connection Place of installation The protective range of the surge arresters is limited. The place of installation must therefore be as close as possible to the equipment to be protected. The distance to earthed or live parts must be in accordance with relevant standards. Attention The gas diverter should not point in the direction of another system component, so that the hot gases do not cause any damage during blow-out. Do not mount the arrester without intermediate plate [5 / Fig. 3.]. The arresters must be fitted vertically or suspended. If non-vertical installation is desired, confer with the manufacturer. Installing of the arrester The contact faces of the flanges of the arresters must be bright. The arresters can be mounted with 3 head screws or stud bolts M10 [Fig. 4. / Fig. 5.]. Siemens AG 03/2008 5

Fig. 4. Mounting In other respects, the arrester must be installed at site in accordance with local conditions. Earthing To ensure safe, reliable function of the arrester and optimal protection, earthing must be effective (low earthing resistance, short earthing connection). For earthing purposes the bottom flange of the surge arrester is equipped with one M12 bolt. So as not to reduce the protection level of the arresters the earthing connections should be as short and straight as possible. (Take account of the minimum cross-section of the conductor). Fig. 5. Connecting lug for earth connection Terminal For the connection between phase and surge arrester there are the following possibilities: Flat connection, aluminium [Fig. 6.] (Standard) 6 Siemens AG 03/2008

Fig. 6. Connection tag 3EB4 xxx-xxxx2-xx Pay attention to the electrochemical compatibility of the materials utilised. Siemens AG 03/2008 7

Disposal arrester and arrester accessories Surge arresters and the accessories are an environmentally compatible product. In disposal, priority must be given to reuse of the materials. Environmentally acceptable disposal of the surge arresters and the accessories is possible in line with current legislation. The following materials have been used to make up the device: Steel, copper, aluminium, PTFE, cast resin or cast-resin-impregnated fabric, glass-fibre-reinforced plastics, polyurethane, rubbers for sealing, ceramics, electronic components and silicon rubber (VMQ), ceramics (porcelain, metal oxide). The device can be recycled as mixed scrap, or, if it is dismantled as far as possible, in a more environmentally acceptable way as sorted scrap with a mixed-scrap residual portion. The arrester resistors of metal oxide (MO) should be disposed of as industrial waste similar to domestic garbage (not as building rubble). In as-supplied-by-siemens state, the device incorporates no hazardous substances in the sense of the pertinent regulations in Germany. If the device is to be operated outside Germany, the locally applicable laws and regulations must be followed. Local customer support offices will be able to answer any questions concerning disposal. Maintenance Warning Before any work starts: switch off and isolate secure against reclosing verify that equipment is dead earth and short circuit the equipment cover or fence off nearby live parts Death, severe injury and considerable damage to property and environmental damage may result if the safety instructions are not followed. Confirm that these safety measures have been carried out. Regular maintenance of the surge arrester is not required. Inspections are limited to the checking the arrester for signs of overloading (black or burned spots at the blow-out hole in the flange). In this case the arrester must be replaced. Cleaning of the silicon sheds is recommended annually or after 1.000.000 km travelled. The arrester is resistant to the usual cleansing agents and methods used in the rail area. If it is cleaned by hand, only use clear water or soap water, and only soft cloths or sponges. Use other cleaning liquids only after consulting the manufacturer. Attention Do not use solvents or abrasive substances. 8 Siemens AG 03/2008