BUILDING CODE VARIANCE

Similar documents
The Building Codes A.R.E. Building Design and Construction Exam Prep

HERMIT S REST GRAND CANYON NATIONAL PARK BUILDING CODE REVIEW

PROPOSED CHANGE TO THE 2012 BUILDING CODE O. REG. 332/12 AS AMENDED

BUILDING CODE COMMISSION

PRESCRIPTIVE COMPLIANCE METHOD

APPLICATION NUMBER:, TAX MAP KEY: STREET ADDRESS:, PRPOJECT: APPLICANT:, PHONE NO: MAILING ADDRESS:, FAX NO:

Applying the Building Code During Design

Section 1 OBC FADS /13 Access to Parking Areas

WHO IS THIS COURSE FOR?

PRESCRIPTIVE COMPLIANCE METHOD

2012 IBC Assembly Means of Egress. Based on the 2012 International Building Code

Accessible Means Of Egress

2009 IBC Section 1024 Approved Luminous Egress Path Markings

High Piled Combustible Storage Guideline

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck)

2007 Title 24 Accessibility Code Updates and ADA Issues

Accessibility for Ontarians with Disabilities Act (AODA), 2005

Reference Guide: Mid-Rise Wood Construction in the Ontario Building Code Report by Morrison Hershfield (January 2015)

Newton Group CANADACAR SYSTEM. Basic Construction of the CANADACAR System. CANADACAR Module Format

4188 East Andrew Johnson Highway Morristown, TN

WON-DOOR CORPORATION Won-Door FireGuard Applications

BUILDING CODE PRESENTATION

Comparison of the life safety elements of the 1997 UBC and the IBC 2000.

Building Codes and Ordinances ARC 227

CONSTRUCTION TECHNOLOGY UPDATE

Vehicle Impact Barriers for Elevated Structures

RESIDENTIAL BUILDING REQUIREMENTS

BRADYGLO EMERGENCY EGRESS MARKING HANDBOOK

Walking-Working Surfaces

ICC CODE CORNER 2012 IFC Code & Commentary

Effective Date: 14-March Table of Contents

2003 International Residential Building Code

Code Requirements for Existing Buildings. R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617)

From the ADA and ABA Accessibility Guidelines for Buildings and Facilities

11.1.2* Adjacent Hazards or Design Methods. For buildings with two or more adjacent hazards or design methods, the following shall apply:

CITY OF DANA POINT. COMMUNITY DEVELOPMENT, BUILDING AND SAFETY Golden Lantern, Suite 209 Dana Point, CA

Q. Do residential and historical buildings that are going to be protected with sprinklers need to conduct an LSE?

GENERAL BUILDING HEIGHTS AND AREAS

2018 APPENDIX B BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1 AND 2-FAMILY DWELLINGS AND TOWNHOUSES)

(6) Crawl boards and ladders used for roof work shall be securely fastened over the ridge of the roof or be otherwise effectively anchored.

Code Requirements for Existing Buildings. R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617)

WOOD USE IN NONCOMBUSTIBLE BUILDINGS

PLANS REVIEW CRITERIA - COMMERCIAL BUILDINGS

STAIRWAYS, HANDRAILS, AND GUARDRAILS (RESIDENTIAL)

CODE COMPLIANCE PLAN REVIEW PROCEDURES

What is a Won-Door FireGuard Door?

Curb Ramps [ 4.7.3] [ 4.7.2; 4.8.2; 4.1.6(3)(a)] [ 4.3.7] ADA Accessibility Survey Instructions Curb Ramps Page 1 of 6

Mezzanine basics. When workspace is tight, a mezzanine can raise your facility's capacity and productivity to a new level.

GENERAL BUILDING HEIGHTS AND AREAS

Florida Accessibility Code for Building Construction

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

The Construction Industry : The most dangerous industry in Singapore?

780 CMR: 9 th Edition Massachusetts State Building Code. Presented to: BSA Codes Committee. DATE: January 20, 2016

The Uniform Building and Accessibility Standards Regulations

PLAN SUBMITTAL REQUIREMENTS - ARCHITECTURAL

TENTS AND OTHER MEMBRANE STRUCTURES

ELEVATORS, LULAS AND PLATFORM LIFTS

Loading Dock Buyers Guide

Combustible Exterior Wall Cladding Systems: An ICC Perspective

PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION

INTERIOR FINISHES CHAPTER 8

HOT SPRINGS FIRE DEPARTMENT EVALUATION OF DOWNTOWN LEGACY STRUCTURES Savoy Hotel Thompson Building Dugan Stewart Building May 16, 2012

ARTICLE 4 SUPPLEMENTARY PROVISIONS

ECNAMRFO ER P R FO ED EER IN G EN / S N TIO LU O S E G A R TO S

FCIA Webinar Gypsum Wall Patching

INTERIOR FINISHES CHAPTER 8

Minnesota Healthcare Engineers Association, Fall Conference. Bob Dehler, P.E. Engineering Program Manager September 14, 2017

Minnesota Health Care Engineers Association

Overview of Revised School Regulation

Sawmill Safety & Health. Presented By: John Boysen Safety Consultant OHSA Consultation Program

780 CMR CHAPTER 34 EXISTING BUILDINGS STRUCTURES

CUSTOMER ASSISTANCE GUIDE BUILDING PERMIT APPLICATION SUBMITTAL REQUIREMENTS COMMERCIAL AND MULTI-FAMILY

Scaffolding. Safety Guide. STOP! Before you climb

University of Texas. Austin, TX. TAS Variance Application Guidelines For Qualifying Historic Structures

10/23/2011. Plan Examination. Plan ExaminationPurpose. Catch problems in advance of construction.

Universal Panels & Accessories

City of Tacoma Planning and Development Services

FACT SHEET #2 DECK INFORMATION

P11 Handling and Storage E212 - Facilities Planning and Design

Advantages. - They are quick, clean and. sizes, floor types and construction systems mean the mezzanines can be adapted to meet specific client needs.

2012 INTERNATIONAL CODES SIGNIFICANT CHANGES

ARCHITECTURE & DECORATION RULES 1/6

ELECTRIC METERING GENERAL

A HOMEOWNER S GUIDE TO ACCESSORY DWELLING UNITS

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

First Revision No NFPA [ Section No ]

Access Ladders And Disappearing Stairways: Code Compliant Solutions

P90 PALLET RACKING SYSTEM. The versatile solution for static and dynamic pallet storage

Industrial Work Platforms, Equipment Platforms & Mezzanines

PROF. PAUL C. KING RA New York City College of Technology. Learning Community. Spring 2011

Government Market Brochure GSA Contract GS-07F-6106P

Speedlock Pallet Racking

Product Selection Guide

FIRE AND SMOKE PROTECTION FEATURES

INTERIOR FINISHES CHAPTER 8

Maximize Your Space. Mezzanines are ideal for:

Building Code 8 th Edition

Safety barrier to a deck located adjacent to a retaining wall at Oraka Beach Road, Mahia

Transcription:

BUILDING CODE VARIANCE April 2009 06-BCV-011-R1 Page 1 of 8 DISCUSSION MULTI-LEVEL STORAGE RACKING SYSTEMS The Alberta Building Code 2006 contains no specific requirements for multi-level storage racking systems. Manufacturers of these types of structures have requested that they be considered as special and unusual structures according to Article 3.2.2.2. and be designed according to good fire protection engineering practice. Multi-level storage racking systems differ from high rack storage systems. In traditional high rack storage systems, access to the commodities is provided by means of ladders or robotic material handling systems. Multi-level storage racking systems, however, have intermediate work platforms designed to enable access to the stored commodities without the use of ladders. Various safety codes officers have interpreted the design of the racking systems as being equivalent to individual storeys, mezzanines or interconnected floor spaces. However, due to the low occupant loads and the restriction on access to the general public that are inherent in these systems, manufacturers are of the opinion that they do not fit in the definition of mezzanines, storeys or interconnected floor spaces. Some of the questions asked pertaining to the multi-level storage racking system are: Should the various levels in the storage racking systems be considered as mezzanines and be limited by the requirements of Sentences 3.2.1.1.(3), (4) or (5)? Should the various levels in the storage racking systems be considered as individual storeys and therefore contribute to the overall building height? Should the upper levels of the storage racking system be allowed to exceed the maximum travel distances to an exit as required by Subsection 3.4.2.? What types of commodities are permitted to be stored within the racking systems? What is the maximum allowable height of the storage racking system? Is a barrier-free path of travel required within the storage racking system? Unless stated otherwise, all Code references in this STANDATA are to Division B of the Alberta Building Code 2006. Issue of this STANDATA is authorized by the Acting Chief Building Administrator [Original Signed] Chris Salvian, P.Eng. Alberta Municipal Affairs Safety Services, 16th Floor, 10155-102 Street, Edmonton, Alberta, Canada, T5J 4L4 Safety Codes Council, Suite 1000, 10665 Jasper Avenue, Edmonton, Alberta, Canada, T5J 3S9

If one of the levels of the storage racking system is higher than 18 m above the floor, should it be considered as a tall building according to Subsection 3.2.6.? Parts 3 and 4 of the Alberta Fire Code 2006 contain provisions for the storage of products that may affect the design of the storage racking system, therefore it is highly recommended to solicit the input of local fire prevention and/or fire department personnel prior to applying for a building permit to construct a multi-level storage racking system. Please refer to the following publications for additional information on good fire protection engineering principles related to time-based egress analyses, occupant behaviour during fire conditions and emergency movement of building occupants: The SFPE Handbook of Fire Protection Engineering, Third Edition, published by the National Fire Protection Association (ISBN 087765-451-4) DEFINED TERMS The words and terms in italics in this STANDATA have the following meanings that are specific to this STANDATA only and are not intended to be used in other contexts: Access level means an intermediate walkway within a multi-level storage racking system for personnel access. Multi-level storage racking system means a self-supporting structural facility within a building having one or more intermediate access levels. CODE REFERENCES Sentence 3.2.2.2.(1) states: 3.2.2.2. Special and Unusual Structures 1) A structure that cannot be identified with the characteristics of a building in Articles 3.2.2.20. to 3.2.2.83. shall be protected against fire spread and collapse in conformance with good fire protection engineering practice. (See Appendix A.) (See also A-3 and A-3.2.5.13.(1) in Appendix A.) Appendix note A-3.2.2.2.(1) states: A-3.2.2.2.(1) Special and Unusual Structures. Examples of structures which cannot be identified with the descriptions of buildings in Articles 3.2.2.20. to 3.2.2.83. include grain elevators, refineries and towers. Publications that may be consulted to establish good engineering practice for the purposes of Article 3.2.2.2. include the NFPA Fire Protection Handbook, Factory Mutual Data Sheets, and publications of the Society for Fire Protection Engineering. Page 2 of 8

VARIANCE 06-BCV-011 Multi-level storage racking systems are permitted to be classified as special and unusual structures according to Sentence 3.2.2.2.(1), provided the following features are included in the design. 1. GENERAL 1.1. A multi-level storage racking system shall be designed for the storage, accessing, retrieval, packaging and distribution of products in conformance with the Alberta Fire Code 2006. 1.2. A fire safety plan shall be prepared and submitted along with the application for building permit in accordance with Section 2.8. and Article 3.2.2.5. of Division B of the Alberta Fire Code 2006. 1.3. A multi-level storage racking system shall be designed and arranged to prevent access to persons other than employees. 1.4. A multi-level storage racking system is permitted in buildings of 1.4.1. medium- and low-hazard industrial occupancies, or 1.4.2. mercantile occupancies. 1.5. A multi-level storage racking system is not required to conform to the requirements of Subsection 3.2.6. or Section 3.8. 2. CONSTRUCTION 2.1. All structural and supporting elements of a multi-level storage racking system, including posts, beams, decks, access levels, connections, concrete slabs and foundation elements, shall 2.1.1. be designed in accordance with Part 4, 2.1.2. have a flame-spread rating not more than 25, and 2.1.3. have a smoke developed classification not more than 50. 2.2. Except as required by Item 2.3., access levels shall be of open construction consisting of steel grating or open steel floor planking, with not less than 70% open face area. 2.3. Access levels shall be of solid construction consisting of steel plate or steel roof decking with a top substrate that forms a serviceable floor area where the multi-level storage racking system is designed to store 2.3.1. Group A, B or C plastics, as defined in NFPA 13, Installation of Sprinkler Systems, Page 3 of 8

2.3.2. rubber tires, or 2.3.3. combustible fibres. 2.4. Guards in conformance with Article 3.3.1.18. shall be provided 2.4.1. at all edges of access levels, and 2.4.2. around all openings between access levels. 2.5. Toe-boards extending from the surface of the access level to a height not less than 125 mm above the surface of the access level shall be provided 2.5.1. at all edges of access levels, and 2.5.2. around all openings between access levels. 2.6. Except where the access levels are of open construction as required by Item 2.2., noncombustible drafts stops extending to not less than 450 mm below the surface of the access level above shall be provided 2.6.1. at all edges of access levels, and 2.6.2. around all openings between access levels. 2.7. All access levels, including the ground floor level, of a multi-level storage racking system shall have a headroom clearance not less than 2 100 mm, including any projections by sprinkler heads, piping or building services. 3. SIGNAGE 3.1. A sign shall be posted in a conspicuous location on each access level to indicate the maximum permissible design loads for each access level in a multi-level storage racking system. 3.2. Signs prohibiting smoking shall be posted in conspicuous locations on each access level in conformance with Article 2.4.2.2. of Division B of the Alberta Fire Code 2006. 4. LIGHTING AND EMERGENCY POWER SYSTEMS 4.1. Every access level shall be equipped to provide illumination at floor or tread level and at angles and intersections at changes of level where there are stairs or ramps to an average level not less than 4.1.1. 50 lx for regular lighting, and 4.1.2. 10 lx for emergency lighting. Page 4 of 8

4.2. An emergency power supply shall be provided in accordance with Subsection 3.2.7. 5. FIRE PREVENTION 5.1. Portable Extinguishers 5.1.1. Every access level shall be provided with portable extinguishers in conformance with the Alberta Fire Code 2006. 5.2. Fire Alarm and Detection Systems 5.2.1. A fire alarm system complying with Subsection 3.2.4. shall be installed. 5.2.2. In addition to the requirements of Subsection 3.2.4., every egress stair shall be provided with manual stations 5.2.2.1. at the entrance to the each egress stair on every access level, and 5.2.2.2. at the bottom of each egress stair at the ground floor level. 5.3. Provisions for Firefighting 5.3.1. A floor area containing a multi-level storage racking system shall be protected by an automatic sprinkler system that shall be designed, constructed, installed and tested in conformance with 5.3.1.1. NFPA 13, Installation of Sprinkler Systems, or 5.3.1.2. the appropriate NFPA standard for the most severe hazard to which the multi-level storage racking system is exposed. 5.3.2. Notwithstanding any of the provisions of the standards in Item 5.3.1., sprinkler protection shall be provided under all platforms and access levels. 5.3.3. Combustible sprinkler piping is not permitted in a multi-level storage racking system. 5.3.4. Equipment forming part of a fire protection system shall be protected from freezing if 6. EXITS AND AISLES 5.3.4.1. it could be adversely affected by freezing temperatures, or 5.3.4.2. it is located in an unheated area. Page 5 of 8

6.1. Aisles within a multi-level storage racking system shall conform to the Alberta Fire Code 2006. 6.2. Except as permitted by Item 6.3., each access level of a multi-level storage racking system shall be provided with not less than two egress stairs located remotely from each other and located so that the travel distance from anywhere on the multi-level storage racking system to the nearest egress stair shall be not more than 15 m. 6.3. Any single access level in a multi-level storage racking system may be served by a single egress stair leading to the access level immediately below provided, 6.3.1. the access level is not more than 200 m² in area, including the area occupied by the storage racks, 6.3.2. the travel distance from any point on the access level to the bottom of the egress stair on the access level below, including the travel distance along the egress stair, is not more than 25 m, and 6.3.3. the access level below is provided with two separate egress stairs or exits. 6.4. Egress stairs required by Items 6.2. or 6.3. may be provided by means of open, unenclosed stairs serving, 6.4.1. not more than four access levels, where the multi-level storage racking system is intended for the storage of commodities, and 6.4.2. not more than two access levels, where the multi-level storage racking system is intended for the storage of plastics, rubber tires or combustible fibres. 6.5. Except as permitted by Item 6.6., the maximum travel distance from the bottom of an egress stair to an exit along a main aisle at the ground floor level shall be not more than 30 m. 6.6. The maximum travel distance required by Item 6.5. is permitted to be more than 30 m, provided a time-based egress analysis has been performed using the following formula: T ET H H V + V M + M ( T N ) + T td td td = + lg s s s lg ( co N co ) SF where: Page 6 of 8

T ET = the total egress time from the bottom of an egress stair to an exit, not more than 4 min., H td = horizontal travel distance within the multi-level storage racking system, in metres, H s = occupant egress speed not more than 1.0 m/sec for horizontal egress routes, V td = vertical travel distance within the multi-level storage racking system, in metres, measured on the diagonal along the nosing of the stairs, V s = occupant egress speed not more than 0.6 m/sec for vertical egress routes, M td = horizontal travel distance on the main floor, in metres, M s = occupant egress speed not more than 1.0 m/sec for horizontal egress routes on the main floor, T lg = time assigned to each lift gate within an egress route, not less than 10 sec, N lg = number of lift gates in the egress route, T co = time assigned to each at-level conveyor cross-over, not less than 5 sec, N co = number of at-level conveyor cross-overs in the egress route, SF = safety factor, not less than 1.5. 6.7. The occupant load on each level of the multi-level storage racking system shall not exceed 10 persons per egress stair. 6.8. A dead end aisle shall not exceed 3 m where the platform or walkway is provided with two or more egress stairs or exits. 6.9. Conveyors, trolleys, tracks or any other similar mode of product transportation within the aisle or walkway shall not reduce the clear widths required by the Alberta Fire Code 2006. 6.10. A single egress route shall contain 6.10.1. not more than two lift-gates, Page 7 of 8

6.10.2. not more than two at-level conveyor cross-overs, or 6.10.3. not more than one lift-gate and not more than one at-level conveyor cross-over. 6.11. Where a lift-gate is incorporated along an egress route, each lift-gate shall be 6.11.1. equipped with a positive lock when open, and 6.11.2. designed to automatically stop the conveyor belt that it serves when the lift-gate is open. 6.12. Where an at-level conveyor cross-over is incorporated along an egress route, 6.12.1. handrails spaced not more than 1 m apart and parallel to the direction of travel shall be provided on both sides of the at-level conveyor cross-over, 6.12.2. a clearly identified and easily accessible switch that will stop the conveyor shall be located at each at-level conveyor cross-over, and 6.12.3. stairs approaching at-level conveyor cross-overs shall be marked to indicate that they are readily identifiable as part of the egress route. This VARIANCE applies throughout the Province of Alberta. Page 8 of 8