Measuring trace impurities in HyCO, regeneration hydrogen and inert gases Los Gatos Research (LGR)

Similar documents
Diode laser analyser LS4000 Ammonia slip measurement for DeNOx process

50 Years of PSA Technology for H2 Purification

ABB Measurement & Analytics Trace HCl measurements in coal-fired power plant emissions using Cavity Enhanced Laser Absorption Spectroscopy

PERP/PERP ABSTRACTS Carbon Monoxide PERP 09/10S11

Evaluation of Hydrogen Production at Refineries in China. The new UOP SeparALL TM Process. Bart Beuckels, UOP NV

Aurora TDLAS analyzers for Hydrogen Recycle Applications

MAX300-RTG PRODUCT NOTE. Real-Time Gas Analysis Process Automation and Control Product Quality Analysis. Industrial Process Mass Spectrometer

APPLICATION NOTE. UOP : Analysis of Trace CO and CO 2 in bulk H 2 and Light Gaseous Hydrocarbons by GC

Greenhouse Gas Measurement Technology

PRISM Membrane Systems for petrochemical applications... tell me more

ABB Measurement & Analytics Monitoring cement plant stack emissions using FTIR

Trace Moisture Contamination in Ultra-High Purity Phosphine: Techniques for Measurement and Control

Chemistry of Petrochemical Processes

A Single Analyzer Solution for Refinery Flare Emissions Monitoring (40 CFR 60 Subpart Ja) Using Mass Spectrometry

MOLECULAR GATE TECHNOLOGY FOR (SMALLER SCALE) LNG PRETREATMENT

WWT Two-Stage Sour Water Stripping

Measurement made easy

Helbio HHG series. Applications: Industrial processes requiring Hydrogen Automobile Refueling Stations Power production via Fuel Cells

APPLIED. Measuring Odorants in Natural Gas Pipelines. Application Summary. Analytes: Odorants (i.e. mercaptans, thiophenes)

Synthesis Gas Processes for Synfuels Production

Carbon To X. Processes

Hydrogen is a particularly

HYDROGEN MEMBRANE OVERVIEW

HIGH PUITY CARBON MONOXIDE FROM A FEED GAS ARNOLD KELLER AND RONALD SCHENDEL KINETICS TECHNOLOGY INTERNATIONAL CORPORATION MONROVIA, CALIFORNIA

Measuring moisture in ultra-high-purity gases

Measurement & Analytics Measurement made easy. AlSCAN TM and AlSCAN TM Argon Hydrogen analysis in liquid aluminum

Multi-component gas analysis with speed, repeatability, and reliability.

The Rectisol Process. Lurgi s leading technology for purification and conditioning of synthesis gas

icap 7000 Plus Series ICP-OES Streamlined performance and ultra-low ICP-OES detection limits for routine laboratories

Fpollutant-free zero air for analytical

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Parker N2-04

Techno-Economic Analysis for Ethylene and Oxygenates Products from the Oxidative Coupling of Methane Process

FT-GTL UNLOCKS VALUE FROM NATURAL GAS

Measurement made easy

Ambient Air Quality Monitoring Baseline Report, Kirby Misperton A Wellsite, KM8 Production Well

Measurement & Analytics Measurement made easy. Advanced spectroscopy software for quantitative and qualitative analysis Horizon MB FTIR

RELIABILITY OF TOC RESULTS IN ULTRAPURE WATER ANALYSIS

Two Great Technologies Together At Last. The 700 Series NanoTrace Moisture And Oxygen Analyzers

Prima PRO process mass spectrometer

Hydrazine, sodium and dissolved oxygen measurement The power of boiler chemistry

WORLDWIDE REFINERY PROCESSING REVIEW. Third Quarter 2011

CO 2 Capture and Storage: Options and Challenges for the Cement Industry

SpectraSensors SS500 Mid-Sensitivity Moisture Analyzer

An Opportunity for Methanol; the Production Starting from Coal

PROCESS ECONOMICS PROGRAM. Report No by NICK KORENS ROBERT W. VAN SCOY. January private report by the PARK, CALIFORNIA

DR1000 Flying Laboratory, Drone Environmental Monitoring

Thermo Scientific icap 7000 Plus Series ICP-OES. Gain more power. experience more performance

ENERGY CARRIERS AND CONVERSION SYSTEMS Vol. I - Hydrogen Separation and Handling - Itsuki Uehara

The Right Analytical Method for the Right Application: TOC Analysis for Cleaning Validation

Process Gas Monitoring In Petroleum Refineries

High-precision MIR trace gas analysis for environmental applications

Item Hydrogen Gas Plant

Continous Emission Monitoring: Methods, Regulations and QA/QC. Anders Arvidsson, Opsis AB, Sweden

BIOGAS PURIFICATION AND UTILIZATION. ENVE 737 Anaerobic Biotechnology for Bio-energy Production

For highest levels of purity

PERP Program New Report Alert

Hydrogen Production via Biomethane Reforming in DBD Reactor

Bitumen Upgrader Residue Conversion to Incremental Synthetic Fuels Products

This is a draft revision of the briefing, and any comments are welcome please them to Becky Slater on

Field test at Gehrkescher Hof in Wilmshagen/Germany

GASIFICATION THE WASTE-TO-ENERGY SOLUTION SYNGAS WASTE STEAM CONSUMER PRODUCTS TRANSPORTATION FUELS HYDROGEN FOR OIL REFINING FERTILIZERS CHEMICALS

ABB MEASUREMENT & ANALYTICS ANALYTICAL MEASUREMENT. Ethylene plant production excels with the PGC1000

Technical Note TN-114 rev 16 wy/wh.11-04

Treatment Options for Molten Sulfur

IGCC Plants : a Practical Pathway for Combined Production of Hydrogen and Power from Fossil Fuels

Improving H 2 O Measurement in Catalytic Reformer Hydrogen Recycle Streams

GT-LPG Max SM. Maximizing LPG Recovery from Fuel Gas Using a Dividing Wall Column. Engineered to Innovate

Plastics Recycling. Datchanee Pattavarakorn Industrial Chemistry, Science, CMU

MATERIALS OF CONSTRUCTION

Technical background on the LanzaTech Process

Lurgi s MPG Gasification plus Rectisol Gas Purification Advanced Process Combination for Reliable Syngas Production

Development status of the EAGLE Gasification Pilot Plant

Capillary GC Troubleshooting: a Practical Approach

High performance radio frequency generator technology for the Thermo Scientific icap 7000 Plus Series ICP-OES

Process description The Johnson Matthey/BP fixed-bed FT technology comprises a series of reaction vessels charged with a proprietary BP catalyst.

10/2/2013. Gas CHEMICAL PLANTS AMMONIA METHANOL UTILITIES TOWN GASS SUPPLIES ENERGY INTENSIVE INDUSTRIES. Power Generation

// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.

Solutions. Integrated Analyzer Systems & Services. Your Global Partner For Customized Analytical Solutions

Geothermic Fuel Cell Applications in Coal Coal Gasification---Coal to Liquids (Summary Highlights)

Using the Pulsed Flame Photometric Detector (PFPD) for Low-level Analysis of Organophosphorus Pesticides

Totalflow analyzer products Precisely what you expect

MULTI-WASTE TREATMENT AND VALORISATION BY THERMOCHEMICAL PROCESSES. Francisco Corona Encinas M Sc.

ICP-OES. Varian Vista-MPX CCD Simultaneous ICP-OES

PRODUCTION OF SYNGAS BY METHANE AND COAL CO-CONVERSION IN FLUIDIZED BED REACTOR

Sensor Technologies used in Portable Gas Monitors. HA University

BIP Technology: the highest purity gases consistently

The Proper Mechanism for Field Validating Moisture Analyzers. GE Measurement & Sensing GE Oil & Gas

IR READY TO GO. Spectrum Two FT-IR Spectroscopy

Heated FID 109A. Rack Mount/Table Top NMGOC Analyzer

Mid Infrared Spectroscopy for Rapid and Cheap Analysis of Soils

Underground Coal Gasification (UCG), its potential and its challenges

Advanced Hydrogen and CO 2 Capture Technology for Sour Syngas

Plastic to Fuel Technologies

Latest Development of Lurgi s MPG-technology Update on Hydrogen Unit for NWU Project

21/05/2014 FTIR AS HCN MEASUREMENT METHOD IN A FLUID CATALYTIC CRACKING UNIT. G. Lenaers, E. Damen, R. Brabers, W. Aerts, B. Baeyens, W.

6515 Series Measurement of CO2 in Flue Gases. A simple Katharometer-type measuring system for CO2 in flue gases as a guide to combustion efficiency

Transcription:

Application note AN/ANALYTICAL/001 EN Rev. D Measuring trace impurities in HyCO, regeneration hydrogen and inert gases Los Gatos Research (LGR) The new LGR-ICOS TM laser process analyzer from ABB provides a simple, robust and sensitive method of simultaneously measuring multiple trace impurities in industrial gases Measurement made easy Introduction From measuring HyCO products to hydrogen recovery, many gas monitoring applications for trace impurities use legacy technologies. These include mass spectrometry, gas chromatography, FTIR and even paper tape-based methods. Each of these has a well-known set of limitations such as costly consumables, limited sensitivity, drift, insensitivity, cross sensitivity between different targets and so on. This publication examines how its high speed, lack of cross sensitivity and high precision make the LGR-ICOS analyzer an ideal analyzer for three important applications: monitoring H2S and other impurities in (HyCO) fuel gas measuring multiple trace species in recovered hydrogen (for example, for regeneration) QC / certification of ultrapure inert gases (for example, from air separation units) A new analyzer from ABB the LGR-ICOS analyzer uses fourth-generation cavity enhanced absorption spectroscopy (CEAS), a technology already well-proven for remote atmospheric monitoring, laboratory and medical research, and semiconductor process applications. The LGR-ICOS analyzer is fully optimized for industrial facilities requiring trace gas monitoring in demanding applications.

Hydrogen recovery and regeneration Many refineries are making changes in their processing patterns to adapt to ongoing market changes and thereby re-optimize profitability. For example, some are increasingly processing lower cost heavy and sour crudes while accommodating trends such as the shifting demand from gasoline towards more distillate, and hence a reduction in naphtha reforming. An overall result is increased production of fuel gas and decreased availability of hydrogen. But there is no decline in the demand for hydrogen; in fact, quite the opposite. While a number of refineries are simply re-balancing their hydrogen budget by buying 'over the fence' hydrogen, these trends are causing many others to look at increasing the utility and value of their existing hydrogen-rich streams. Specifically, hydrogen purification (recovery and regeneration) is gaining in popularity to improve downstream quality, process efficiency, and / or combustion efficiency, depending on the final destination of the hydrogen. In particular, these applications include hydrogen recovered by pressure swing adsorption (PSA) regeneration catalytic systems and hydrogen from steam methane reformers (SMRs). In contrast, the LGR-ICOS analyzer requires no consumables and very little maintenance, except for a simple window cleaning procedure included in a recommended annual maintenance check. This cleaning can be accomplished in just a few minutes. The LGR-ICOS analyzer is also very fast; wavelength scanning of the target absorption lines can be completed in only milliseconds. For recovered hydrogen applications, the other important advantages of the LGR-ICOS analyzer are its ability to simultaneously target multiple specific impurities (for example, CO, CO2 and CH4). That's because the measurement cavity in this analyzer can accommodate multiple tunable lasers. In contrast, earlier cavity-enhanced optical methods, such as cavity ringdown spectroscopy (CRDS), could be configured for multiple targets only by housing several instruments in a single box. The high spectral resolution of the lasers used in the LGR-ICOS analyzer, and the discrete width of the absorption feature also means that the analyzer is highly selective and exhibits minimal cross-interferences from other background gases. The final value and utility of any recovered high-purity hydrogen depends on minimizing trace impurities such as carbon monoxide (CO), carbon dioxide (CO2) and volatile (saturated and olefin) hydrocarbons such as methane (CH4). For example, a typical target value for regeneration purposes is <10 ppm CH4. And, of course, for any excess hydrogen that is exported over the fence for applications such as fuel cells, compositional purity will determine value and price. Hence there is a growing need for a robust method of measuring hydrogen purity. Currently, the most commonly used method for measuring hydrogen purity in refineries is gas chromatography (GC), mainly for want of a superior alternative and in spite of its well-known drawbacks. These include limitations on absolute accuracy resulting in a concomitant need for frequent calibration, slow speed and costly consumables (for example, columns and carrier gases). Slow speed is always a potential issue with GC, particularly in applications that require fast response in process control plant operations. With GC, operator alerts have an inevitable time delay, often meaning the operator has to stop the process before it goes out of specification to avoid contaminating good product or poisoned catalysts. The other major limitation of GC is the cost of routine maintenance. In fact, one of the first things a GC supplier tells a customer is how to open the oven and carefully change the separation column. Also, GC ideally benefits from having a skilled and experienced operator. Measured H2S, ppm 200 150 100 50 0 Measured values Measured = actual line Best fit Measured = 0.007+1.002* actual R 2 = 0.99990 0 50 100 150 200 Actual H2S, ppm Fig. 1: Measurements of H2S recorded by the analyzer show excellent linearity and accuracy over a dynamic range exceeding 3 orders of magnitude Unlike other optical methods, the laser-based LGR-ICOS analyzer reports data over an extremely wide dynamic range often up to 6 decades. Thus, the analyzer is well suited for reporting, for example, methane in complex process streams containing hundreds of ppm or in high purity gases at single-digit ppb levels. As an example of excellent linearity and dynamic range, Fig. 1 shows measurements of H2S recorded from 0 to 200 ppm, with a LDL of 5 ppb. 2 AN/ANALYTICAL/001 EN Rev. D Measuring trace impurities in HyCO, regeneration hydrogen and inert gases Los Gatos Research (LGR)

Analyzer configuration Gas analyte Measurement range Low High Precision (2, 10 sec) LDL (3, 10 sec) Accuracy (% of reading) Response time T 90/10 CH4 + CO + CO2 + H2O CH4 0 50 ppb 0 100 % 0.5 ppb 0.75 ppb < 1 % < 15 sec CO 0 5 ppm 0 5000 ppm 50 ppb 75 ppb < 1 % < 15 sec CO2 0 10 ppm 0 1 % 100 ppb 150 ppb < 1 % < 15 sec H2O 0 10000 ppm 0 70000 ppm 10 ppm 15 ppm < 1 % < 15 sec H2S + CO2 H2S 0 1 ppm 0 5000 ppm 10 ppb 15 ppb < 1 % < 15 sec CO2 0 25 ppm 0 20 % 250 ppb 375 ppb < 1 % < 15 sec Trace O2 O2 0 50 ppm 0 20 % 500 ppb 750 ppb < 1 % < 15 sec % V/V O2 O2 0 1 % 0 100 % 85 ppm 130 ppm < 1 % < 15 sec Table 1: Performance of LGR-ICOS analyzer for trace impurities in inert gases, HyCO, and hydrogen. Measurement accuracy is better than 1 % of reading until precision limited. Measurement range is continuous between low and high ranges (please inquire for details). An additional advantage for the LGR-ICOS analyzer is the ability to combine the monitoring of multiple streams of widely varying concentrations with a single analyzer rather than multiple analyzers covering shorter ranges of measurement. Table 1 shows selected examples of LGR-ICOS analyzer performance in inert gas matrices. Trace measurements with unmatched sensitivity, precision and accuracy show superior performance for both quality assurance and process efficiency applications. Measuring trace impurities in HyCO, regeneration hydrogen and inert gases Los Gatos Research (LGR) AN/ANALYTICAL/001 EN Rev. D 3

HyCO (SynGas) applications HyCO, often called SynGas and historically sometimes called Power Gas, is a mixture of CO, H2 and usually CO2, together with various impurities, that are dependent on the specific origin of the particular HyCO stream. There are numerous sources of HyCO, including steam reforming of natural gas, coal gasification and recycling (for example, from waste to energy conversion plants). It is no longer commonly used for domestic delivery and consumption but its high calorific value and plentiful supply at the typical refinery make HyCO and separated HyCO products (CO and H2) desirable combustion fuels in an overall scheme of maximizing refinery profit. In addition, HyCO and its separated products have significant value as a crucial intermediate resource or feedstock for the production of hydrogen, ammonia, methanol and synthetic hydrocarbon fuels. Raw HyCO is often contaminated with light sulfides (H2S, OCS and small mercaptans). The value of the HyCO product and its utility for both combustion and as a chemical feedstock is greatly enhanced by removing these sulfides from the HyCO mixture and / or from the separated CO and H2 constituents. This is typically accomplished by the use of mixed (iron and other) metal oxides. CO2 and trace moisture (H2O) are the other common and potentially problematic impurities that are usually removed in 'HyCO driers'. As a result, there is a need to monitor trace levels of H2S, H2O and CO2 in pure hydrogen and purified CO. There is also a need to monitor derived mixtures of CO and H2 in dry HyCO. This is currently accomplished by gas chromatography (GC), non-dispersive infrared (NDIR) or ultraviolet (UV) absorption. The advantages and disadvantages of using GC with HyCO are very similar to those discussed previously in the context of hydrogen for regeneration. NDIR instruments provide the benefit of rugged simplicity and low cost. The well-known limitation of NDIR is a lack of specificity. The instrument compares broadband infrared absorption characteristics in several pre-set bands of the infrared spectrum. Where two or more trace impurities absorb in the same spectral region, the onboard computer can sometimes estimate relative composition based on absorption values in one of the other spectral windows. One of the worst culprits for cross sensitivity is H2O, which is present in nearly every source of unpurified HyCO. UV absorption is used for some HyCO applications because sulfides produce a strong and distinctive UV absorption signal compared to H2O and CO2. The problem is that so do other compounds that are sometimes found in HyCO. So again, the issue is cross sensitivity. Both methods typically need frequent calibration. UV absorption methods are typically limited to low ppm concentrations. As a result, UV absorption and NDIR are best suited to monitoring the processing of streams of well-characterized composition where uncertainties are few. They are also suitable for looking for significant process changes. They are a poor match where absolute precision is required, or where HyCO composition is complex and / or subject to variation. In contrast to these broadband, low-resolution methods, the LGR-ICOS analyzer is a precision analytical tool based on quantitative absorption measurements using narrow line tunable lasers. The laser bandwidth is typically less than 3 MHz, which is many orders of magnitude narrower than UV absorption or NDIR measurements and much narrower than the typical interval between absorption lines from different species see Fig. 2, page 5. As a result, the LGR-ICOS analyzer is often immune to interference between multiple species, even in complex mixtures like HyCO. Many HyCO monitoring applications need to measure or certify more than one trace impurity. The high spectral resolution of the LGR-ICOS analyzer means that it is ideal for these uses. Also, unlike earlier cavity-based optical analyzers like CRDS, multiple lasers can be incorporated in a single instrument where necessary, enabling simultaneous measurement of a large number of factory-specified targets. No other optical method offers this multi-species analysis capability in a high precision format. 4 AN/ANALYTICAL/001 EN Rev. D Measuring trace impurities in HyCO, regeneration hydrogen and inert gases Los Gatos Research (LGR)

Ultrapure industrial gases The customizable flexibility of the LGR-ICOS analyzer makes it ideal for suppliers and consumers of a range of ultrapure gases. For example, it is particularly useful for QC and certification of inert gases such as nitrogen and argon, produced from high volume, high purity (for example, cryogenic) air separation units from key on-line sampling through to final loading station testing. Cryogenic air separation has been commercialized for a century now, and process refinements have evolved in parallel with ongoing advances in compression machinery, heat exchangers, distillation technology and gas expander technology. Yet, until the LGR-ICOS analyzer, the state of stream and product analysis methodology has been fairly stagnant. The high sensitivity and absolute accuracy mean that this new analyzer is also an excellent match for suppliers and users of reagent grade calibration gases, such as hydrogen, argon, nitrogen and neon. And the same advantages make the LGR-ICOS analyzer a superior instrument for QC / QA of gases used as inert pressurization blankets in industrial catalyst beds and chemical storage tanks (for example, nitrogen). Fig. 2: LGR-ICOS analyzer produces and locally stores highly resolved absorption spectra of multiple gases in a single scan The high spectral resolution of the laser resolves individual absorption features with no cross interference. The broad utility and flexibility of OA-ICOS technology, compared to older spectroscopic methods such as FTIR, UV fluorescence and NIR, offers clear superiority in the key areas of accuracy and sensitivity. OA-ICOS technology is well-established and routinely used for parts per billion data precision in many of the gases monitored for purity in these industrial gas applications. Measuring trace impurities in HyCO, regeneration hydrogen and inert gases Los Gatos Research (LGR) AN/ANALYTICAL/001 EN Rev. D 5

Summary Every so often, a new analytical technology is developed that provides a powerful new method of performing existing product analysis with important improvements over conventional methods in the form of superior results, greater speed, lower costs and / or simplicity of use. The new LGR-ICOS analyzer represents such a breakthrough for measuring trace gas impurities in industrial gases, because it offers clear advances in not just one or two, but all four of these areas: superior precision lower investment and maintenance costs faster speed simplicity of use Please contact your local ABB Sales office to discuss your application detail and obtain a quotation according to your specific sample stream composition. 6 AN/ANALYTICAL/001 EN Rev. D Measuring trace impurities in HyCO, regeneration hydrogen and inert gases Los Gatos Research (LGR)

Notes Measuring trace impurities in HyCO, regeneration hydrogen and inert gases Los Gatos Research (LGR) AN/ANALYTICAL/001 EN Rev. D 7

Contact us ABB, Inc. Process Automation 3055 Orchard Drive San Jose CA 95134 USA Tel: +1 650 965 7772 Fax: +1 650 965 7074 email: sales@lgrinc.com www.abb.com/measurement Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 2016 ABB All rights reserved AN/ANALYTICAL/001 EN Rev. D 11.2016