Cooling tower efficiency U2 Eco-efficiency resources for the food processing industry

Similar documents
Cooling Tower Water Conservation: Simple Strategies & Advanced Treatment Eric Elam Water Savers LLC, RTS Water August 15 th, 2017

Tech Talk The Importance of Side Stream Filtration in Water and Energy Conservation By Kenn Latzer, Process Efficiency Products, Inc

Water conservation. Best practice guidelines for cooling towers in commercial buildings

Saving Water With Cooling Towers

COOLING TOWER WATER TREATMENT

Thermodynamic Processes

INDUSTRIAL CONSUMPTIVE COOLING PROCESS AND WATER CONDITIONING TECHNOLOGY EFFICIENCIES

Plant Utilities and Energy Efficiency CH505

Water Treatment Program. Training Manual

EXHIBIT A UNIVERSITY OF NEVADA - LAS VEGAS WATER TREATMENT BEST PRACTICES

Run an Efficient Cooling Tower

SODIUM SULPHITE BASED WATER TREATMENT PROGRAM FOR CLOSED CHILLED WATER SYSTEMS

Forward Osmosis Applications for the Power Industry

Cooling Tower Water Treatment. 30A avenue du Pacifique Laval Qc.H7N 3X5 Téléphone

Zero Discharge Treatment Method for Cooling Towers and Heat Exchangers with SP3, I-SOFT-OB, OXYDES & KATALOX LIGHT

Chapter 3.7: Cooling Towers

Forward Osmosis Applied to Desalination and Evaporative Cooling Make-up Water

Content. Cooling Tower Water Treatment...1. Maintaining Water Quality...1. Startup Conditions...1. Blowdown...1. Chemical Treatment...

Cooling Tower Water Savings Stakeholder Meeting #1 - DRAFT California Statewide Utility Codes and Standards Program

How Cooling Towers Function

An evaluation of cooling system water efficiencies and efficiency improvement strategies within Victoria, Australia,

NPDES COMPLIANCE OF COOLING TOWERS BLOWDOWN AT POWER PLANTS WITH RECLAIMED WATER AS SOURCE WATER

Fiberglass Cooling Towers

TOTAL WATER MANAGEMENT IN THE STEEL INDUSTRY. By N. Ramachandran, Ion Exchange (India) Ltd

Radiator Maintenance

Reverse Osmosis. Lecture 17

1000 GPD Marlin Reverse Osmosis Instruction & Owner s Manual

Quality of Rainwater From Rainwater Harvesting Systems in Sanaa. Nagib Ghaleb N. Mohammed, Civil Engineering Department, University of Bahrain

P URE PRO DRINKING WATER SYSTEM USER'S MANUAL REVERSE OSMOSIS SYSTEM. Type of product. Date of purchase. Address

WATER RECYCLING SOLUTIONS

SYMPOSIUM ON INDUSTRIAL APPLICATIONS OF GAS TURBINES

Higher COC and ph Independent Operation of Cooling Water Systems

EFFECTIVE USE OF RECYCLED WATER IN COOLING TOWERS WITH NEW GREEN TECHNOLOGY. Abstract

Reverse Osmosis Desalinators

Water Based Critical Utilities. RO, WFI, and Steam

Water Talk. Volume 8, Issue 8 August 2008 Zero Blowdown, Reality or Fantasy? A Critical Look at the Claims and Possibilities

THE IMPORTANCE OF WATER INTEGRA WATER TREATMENT SOLUTIONS AS FEATURED IN AUSTRALIAN RESOURCE FOCUS

Side Stream Filtration!!

WHITE PAPER. Water Quality. Management for the Plastics Industry. Benefit from Improved. Water Quality. Management.

Green Technologies to Minimize Cooling Tower Water Use

Case Studies in Energy Efficiency and Water Conservation Projects

d&wr desalination & WATER REUSE

Comparing Evaporative Technologies for the Recycling of Produced Waters

IWC REPORT ZLD: New Silica Based Inhibitor Chemistry Permits Cost Effective Water Conservation for HVAC and Industrial Cooling Towers

Distributed by: Phone: , Toll-Free U.S. Fax: , Toll-Free U.S.

A Brief about Reverse Osmosis & Ultrafiltration!!

high cycles cooling tower operation using a revolutionary alkaline treatment program Continuum* AEC (Alkyl Epoxy Carboxylate)

SECTION COOLING TOWER

Owners Manual Models: 200-RODI4-XXX. US Water Systems 4 Stage RO/DI System Installation and Maintenance Manual.

Intelligent Process Cooling Technology Saves on Water and Energy, Improves Productivity

B. System Design and Performance Requirements

Congratulations! Dear Customer,

Keeping the heat transfer surfaces of a cooling tower system clean is widely recognized as the best way to ensure efficient operation.

6.1 Introduction to Wastewater Issues

RO400 USER'S MANUAL. Memo PURE-PRO REVERSE OSMOSIS SYSTEM RO400. Type of product. Date of purchase. Address

RECYCLED WATER AT SYDNEY OLYMPIC PARK. Andrzej Listowski SYDNEY OLYMPIC PARK AUTHORITY

West Michigan s Factory Representative

RO105UV P URE PRO DRINKING WATER SYSTEM USER'S MANUAL. Memo REVERSE OSMOSIS SYSTEM. Type of product RO105UV. Date of purchase.

Aquifier safelock filter information

first flush water diverters water quality first downspout, post/wall mounted and in-ground diverters

RESTAURANTS AND FOOD OUTLETS

For Safe and Delicious Water

White Paper. A Reliable Alternative to Chemicals for Cooling Water Treatment. GWS-1107-D 10/31/11 Copyright 2011 All Rights Reserved

Preliminary Hazard Analysis and Risk Assessment for the Wood Centre Development, Southwood Resources - Huon

JG&DEP Bio- Environmental Solutions GLOBAL WATER CONCERNS

final report Water quality improvement strategy for a processing site

The Basics: Water supply

Water Solutions for the Mining Industry

4709 Hwy 36 South, Suite 10 Rosenberg, TX Phone:

PSP Series Water Purification Systems

Use of Spiral Wound UF in RO Pretreatment

ProMinent Dulcodes UV Disinfection Systems

RAINWATER HARVESTING SYSTEMS

ERT 318/4 UNIT OPERATIONS SEMESTER 1 (2013/2014)

Water for Instrument Processing

CIBSE & SoPHE CPD Technical Evening

Spot Zero Mobile Wash Down System SZMWD SZMWDWH 110v SZ MWDZ SZ MWDZ WH 220v

Safe production with clean water. active Water treatment

Nilan VPL Active heat recovery and cooling (air/air)

Solvent Recovery Systems

WATER RECYCLING PLANT IN WAFRA. Feras Al Salem

Water Quality Specification for Power Supplies

Australian/New Zealand Standard

Green Star SA Public & Education Building v1 POTABLE WATER CALCULATOR GUIDE VERSION 2.0

A Technical Perspective on Controlling Legionella in Building Water Systems

CLEANER PRODUCTION IN FOUNDRY INDUSTRIES

Attachment 1 Amendment 6 - IS6/IAS6: Section 3.8: Amended New Zealand Standard for Spray Chilling Large Mammals and Large Birds

REACTION TANKS ADVANCED MEMBRANE FILTRATION

Green Corrosion Inhibition and. (NGC) for Cooling Water Treatment. Report by Dan Duke Water Conservation Technology International

Water Solutions for Tourism and Leisure

Recovery and reuse of water from effluents of cooling tower

Product Information CHEMGLAZE B 9942 A/B. Coating for Casting Pits. Easy Application Chemglaze B 9942 A/B will bond to damp and wet surfaces.

OPTIMISATION OF WATER USAGES IN THERMAL POWER PLANTS AND A STUDY ON DRY COOLING SYSTEM

REVIEW OF THE INSTALLATION OF A NEW SET OF COOLING TOWERS AT FARLEIGH MILL BRYAN LAVARACK, BRUCE STEVENSON, ROBERT RASMUSSEN

Electricide HG Electrochemical Chlorine Generators

BRS VALUE RO/DI SYSTEM INSTRUCTIONS

Why Fine Filtering for quench oil systems is a must!

Steam Power Station (Thermal Station)

Operation and Maintenance of Electrochlorination Plant

from ENGINEERING up to the complete PLANT, ALL from a single SOURCE MULTI Kühlsysteme GmbH Zschorlauer Straße Aue/Saxony GERMANY

Transcription:

Cooling tower efficiency U2 Eco-efficiency resources for the food processing industry Cool savings Many food processors operate cooling towers to meet the cooling needs of the factory. Cooling towers supply cold water through an evaporative process (described below). This cold water is then used to quickly remove heat from areas such as: hot refrigerant gas from the freezers and refrigerators (refer to Refrigeration efficiency (U5) fact sheet for more information on refrigerators) hot gas from the air conditioning units used to regulate the temperature within the factory hot process equipment and contents such as kettles products immediately after packaging such as hot products packaged in cans. Cooling tower operation is one of the largest water and energy consuming activities within many food processing factories. Often the towers are managed by third-party service providers without question by food processors. This fact sheet provides a basic description of cooling towers to assist food processors in understanding how cooling towers operate. It also provides a list of opportunities that can help food processors to save water, energy and money through more efficient operation. Discussing these opportunities with the service provider is a good way to start improving cooling tower efficiency. Note: It is extremely important that any changes are carried out in consultation with the cooling tower service provider. Evaporation 1 Drift and splash 4 Make-up 3 5 Overflow Fan blowing ambient air 2 Blowdown or bleed off. Warm water flowing into the cooling tower Manufacturing process or air-conditioning unit generating warm water that needs to be cooled. Drain Cooled water flowing back to the process or airconditioning unit 1. As pure water is evaporated off in the cooling tower, salts and minerals are left in the circulating water. These contaminants can cause biological growth, corrosion and scale build up. Therefore these contaminants are removed through the 2. blowdown of the circulating water. To replace the lost blowdown water 3. makeup water is added. Additional water can also be lost as 4. splash or drift (water lost as droplets carried out of the cooling tower with exhaust air). Water can also be sent to drain through the 5. overflow pipe when the level of water in the tower basin rises above a predetermined level.

Reduce blowdown losses Increase cycles of concentration As water evaporates from cooling towers the contaminants, salts and minerals measured as total dissolved solids (TDS) that accumulate can cause biological growth, corrosion and scale resulting in tower damage, poor heat transfer and possibly the growth of harmful bacteria such as Legionella. The sources of contaminants include: salts and minerals already in the makeup water chemicals added to reduce corrosion, scale and biological growth pollutants entering the water during the evaporation phase from the surrounding air such as dust. To reduce build up of these dissolved solids, a portion of the water in the tower is bled off (blowdown). This water loss from the tower is then replaced with fresh incoming makeup water. A conductivity probe in the tower basin initiates blowdown when the levels of dissolved solids exceed a set value. Cycles of Concentration (CoC) compare the level of dissolved solids in the tower s makeup water to the level of dissolved solids in the tower s bleed water. Cycles of Concentration = total dissolved solids in the makeup water total dissolved solids in the bleed water Increasing the number of CoC will reduce the volume of blowdown and consequently the volume of make-up water required by the tower. The maximum CoC for a tower will depend on the quality of the make-up water and the corrosion resistance of the tower s basin and condenser. CoC over five are considered to be efficient but are not always achievable. increasing cycles of concentrations saves water Prepared Foods, a supplier of pre-prepared foods and value-added products, increased the CoC on its cooling tower that serviced a large freezer storage area and the site s blast freezer (used for the initial cooling of products) as part the Water Efficiency Management Plan. By increasing the cycles from 2.6 to five the company was able to save 163 kl annually. (Prepared Foods is an ecobiz participant.) Scale forming ions such as calcium and magnesium can often be precipitated out (e.g. water softeners) or kept in solution (e.g. acids) through effective water treatment, enabling the tower to operate at higher CoC. Reuse blowdown Blowdown water can be reused for other uses around the plant such as cleaning or for toilet flushing, provided it is of sufficient quality and any chemicals, salts and minerals in the blowdown water are compatible with equipment and existing pipework. Table 1 provides an example of corrosion rates for various metals typically used within cooling tower systems. Table 1: Example of corrosion rates 1 Metal Stainless steel Mild steel Copper alloys Corrosion rate (1 MPY* = 25 microns/yr) < 1 MPY < 3 MPY < 0.2 MPY *MPY mils (thousandths of an inch) per year penetration A risk assessment of the intended end use of the blowdown water and also the management of the cooling tower as a whole should be undertaken. 1 Sydney Water Best Practice Guidelines for Cooling Towers in Commercial Buildings, www.sydneywater.com.au/publications/factsheets/savingwaterbestpracticeguidelinescoolingtowers.pdf

Accurate conductivity probes Conductivity probes which are clean and calibrated to the manufacturer s specifications prevent damage to the tower and excessive blowdown. Alternative water sources such as rainwater, condensate, recycled water, process water and bore water can be substituted for mains water where appropriate. Cooling tower savings A brewery, Foster s Australia, uses recycled water treated by reverse osmosis (RO) in its cooling towers, saving $50,000 annually. This water use allows the cooling towers to be run at between 10 and 12 CoC (five CoCs is considered efficient). Chemical use has also been reduced by more than $300,000 annually due to the high quality of the RO water. Water savings in cooling tower SnapFresh a prepared meal processor installed three 22,000 L rainwater tanks to supplement makeup water to its cooling towers. By utilising the site s large roof area the company was able to collect 700 kl in the first quarter of 2008, saving almost $1,000 in just three months. SnapFresh also found its air conditioning unit was producing 3,000 4,000 L of condensate per day. This was captured and put into the cooling towers. As the water quality was close to distilled water with a lower TDS level than mains water, it also allowed a reduction in chemical use. The system cost $20,000 to install but saves approximately $100,000 per year in water and chemical costs giving a payback period of less than three months. Addition of chemicals such as biocides, acids and alkalis to the make up water contributes to the TDS levels in the water. These chemicals are used to control scale, corrosion and biological growth which if not prevented have the potential to damage the system and produce health risks from the growth of harmful bacteria such as Legionella. Alternatives to chemicals are available such as UV radiation and ozone which kill bacteria, and hydrocavitation which can reduce or even remove the need for chemical treatment. Fact sheets Cleaning and sanitising options (W6) and Other treatment options (W9) provide more information on alternatives to chemical addition, including a case study on the use of hydrocavitation in a cooling tower. Side-stream filtration with a rapid sand filter or a high-efficiency cartridge, draws water from the basin and filters out sediment before returning the filtered water back to the tower. These systems are particularly useful if fine dirt, dust, smoke and organic particles in the atmosphere collect in the water. Reduce water losses Leaks Regular monitoring and repair of leaks in the tower casing, basins, connections, pump gland seals, air intake or exhaust ducts is an essential first step for reducing water loss. Splashing Splashing from the tower can be minimised by checking that: the water flow rates or fan speeds are not too high windy conditions are not causing splashing (consider anti-splash louvers or wind beaks). Drift Drift from the towers can be reduced by: installing drift eliminators repairing damaged drift eliminators.

Overflow Unnecessary overflow can be prevented by checking that: the make-up ball float is not too high, allowing water to flow into the overflow drain the water level in one basin is not higher than any connected basins as the water will flow to the lowest basin when the pump is turned off. Adjust the ball float if necessary. most of the tower s piping is below the tower so when the pump is turned off it does not flow into the basin and overflow the overflow pipe is not leaking the fill pipe has not been left on after cleaning. Reduce energy consumption Variable speed drive Installing a variable speed drive on the electric motor of cooling tower fans can reduce drift and save energy. Air chillers Replacing water cooling towers with air cooled chillers saves water, maintenance and chemicals. However possible additional energy costs should be factored into a facilities decision to take this course of action. Replacement of cooling towers with air chillers Prepared Foods, a supplier of pre-prepared foods and value-added products, has replaced two of its energy intensive cooling towers (that provide cooling for the condensers of two large freezers covering 696m 2 ) with energy efficient air-cooled condensers. The new condensers will save the site around 3.19kL a day in potable water. When water savings, water treatment and power costs were considered, less the running costs of the new condensers, the site estimates it will save around $7,200 annually. (Prepared Foods is an ecobiz participant.) Control sequencing Reconfiguring or installing controls to shut down one or more towers to match demand is a proven strategy to achieve efficiency savings. Responding to load saves money Australian Country Choice (ACC), an integrated meat processor, replaced inefficient cooling towers with more efficient models. The towers were set up to allow each one to be turned on and off individually depending on load on the plant. A base load is maintained but towers can be turned off at night or in winter when the load is not as high. This system is currently manually operated but ACC have considered control wiring the cooling towers to allow electronic monitoring and control. This new method of operation saves approximately $1,000 per year. Reduce the load For example the load on air conditioning cooling towers can be reduced by setting thermostats at 25 o C in summer and 20 o C in winter. Simply raising the temperature by 3 o C will reduce water consumed in the cooling tower by approximately 15 per cent. 2 2 Brisbane Water, 2007, Water Sense Factsheet: Cooling Towers, www.brisbane.qld.gov.au/bccwr/lib199/cooling_towers_factsheet.pdf

Improved maintenance and operation On site monitoring and performance contracts with cooling tower service providers Staff responsible for the maintenance and operation of the cooling tower should: read water flow meters on both the makeup and blowdown lines weekly to enable normal patterns of consumption to be established and abnormalities quickly identified (usually a good indication of losses in the system) measure the conductivity of the makeup and bleed lines fortnightly using a conductivity probe (around $150). Probes are also available that measure temperature at the same time. check for any leaks or faults while reading the meters be provided with a report after each service provider visit and analyse the tests results know what chemicals are being used in the cooling tower and their purpose. Cooling tower service providers should understand that water efficiency is a priority. This can be achieved through: performance-based contracts related to reducing water consumption while still keeping scale, corrosion and fouling at an acceptable level occasional independent testing to verify the performance of the cooling tower and provide a second opinion on the operation of the system specifying all proposed treatment regimes to include water and wastewater savings/costs as well as chemical costs. This series of fact sheets provides examples and suggestions to the modern food processor on how to achieve both economic and environmental benefits from eco-efficiency. Visit the project website www.ecoefficiency.com.au for more ideas and case studies. ISBN: 978-0-9775169-7-1 The eco-efficiency for the Queensland food processing industry project is an initiative of the Department of Employment, Economic Development and Innovation and the Department of Environment and Resource Management with technical information provided by UniQuest through the UNEP Working Group for Cleaner Production. SD5934 02/10 This series of eco-efficiency fact sheets will demonstrate the importance of water in a modern food factory and suggest areas where savings can be made. The project website www.eco-efficiency.com.au has more ideas and case studies on water savings across the food industry.