ASSEMBLY INSTRUCTION TG 2002

Similar documents
Installation instructions Thin, flexible multi-foil insulation

EcoHome-Insulation.com. Aluminium Foil Bubble Insulation. General Purpose Insulation. Dry Lining. Cavity Wall. Insulation System.

Insulating systems used in agricultural and industrial buildings


COMP ONENT CATA LO GUE FOR B UILDING YO UR OWN HOME

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

Protan Exposed Membrane Roof. Your design - Our solution

PITCHED ROOF SOLUTIONS

Multi-layer Insulation Blanket for Walls

Multi-layer Insulation Blanket for Walls

COMP ONENT CATA LO GUE FOR INDUSTRIAL BUILDINGS

GypLyner UNIVERSAL Metal framed wall lining system

1 Exam Prep Prov Module: Thermal and Moisture Protection Questions and Answers

TECHNICAL GUIDANCE XXXX 2015 EXXON QUESTION ANSWER. page 1 of 9

TW50. Insulation STANDARD DETAILS FOR 50 MM INSULATION BOARD IN A 100 MM CAVITY. Low Energy Low Carbon Buildings. Wall lining. Inner leaf blockwork

Reflective Insulation Specification & Application Guide for Post Frame and Metal Building Construction

BEARING METAL STUD FRAMING

Thermal Laminate Board.

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

PLATON FOUNDATION WRAP

Part E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague,

CONCRETE FORMWORK CHECKLIST AT SITE

Contents: 3. Benefits of CLT with regard to airtightness. 4. Technical aspects of airtightness. 5. Configurations and specific connections. 6.

HP Partial Fill. Robust, long-lasting protection

Multi-layer Insulation Blanket for Walls

Garage Conversion - Between and Under Joist Applications

Multi-layer Insulation Blanket for use in Walls

Administrative Changes

RETROFIT INSULATION in WOOD ROOFS

Carpenter Level 2 Rev. September 2017

SINTEF Building and Infrastructure confirms that. Unihouse timber frame building elements

INSULATION OWENS CORNING INSULATION PRODUCTS IN THIS SECTION:

PLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION

ITEM 458 WATERPROOFING FOR STRUCTURES

Container Installation Guide

INSULATION RETROFIT DESIGN ENERGY SOLUTIONS CENTRE YUKON GOVERNMENT

URSA MINERAL WOOL URSA Cavity Batts

SITE VISIT REPORT DATE: JOB: NO. OF VISIT: PAGE OF : PURPOSE OF VISIT: CONTRACTOR: Items to be checked Observations Actions SETTING OUT

CHAPTER 3: Modern Methods of Construction (MMC)

V1/0715/AI/TDO1. KORE Loft. Insulated Flooring System Design Guide

Specialists in Acoustic Flooring and House to Flat Conversions

FIRE PROTECTION. GTEC Shaftwall systems 244 GTEC Shaftwall Stairwell systems 248 GTEC Horizontal Shaftwall systems 249 GTEC Encasement systems 250

Product overview:

Gold Bond BRAND Gypsum Sheathing

Isover Installation Guide

Container Installation Guide

Dynamic Bonding Systems B.V. A division of Dutch Bonding Group B.V.

Sarnavap 1000E is an unsupported vapour control layer based on PE-LD (Low Density Polyethylen).

HPW Protocol Reference Manual

DuPont RainVent Batten Installation Guidelines

HOW TO: INSULATE YOUR HOME AND UNDERSTAND U-VALUES GTEC THERMAL BOARD WITH PLASTERBOARD

PATENTS ARE PENDING. Building Dimensions. Exterior Dimensions Roof Edge to Roof Edge

Real Brick Cladding. Iso Klink Pur. Brick Panel System Catalogue

June Non - Residential Refurbishment Internal lining walls

TREAT RISING DAMP AND REDECORATE IN UNDER 24HRS

for New Construction Applications

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

Field Determination of Water Penetration of Windows using Blowerdoor and Infrared Camera

GRP Flat Roofing Edge Trims

LP SmartSide Perfection Shingle

Building Design Data

ACOUSTICAL INSULATION (LAGGING) FOR PIPING AND EQUIPMENT

NATIONAL GYPSUM COMPANY Wood Frame Walls And Ceilings Single- And Double-Layer Construction

URSA MINERAL WOOL URSA 10 & URSA 20 DIVERSO Loft Roll

Construction details:

How do you install yours?

FLUID APPLIED WATERPROOFING

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 Protecting Membranes System Components.

Sandwich panel SPA Product description

Rockwool Blown Cavity Wall Insulation System

Crawl Space Moisture Control

Quality Inspection 8618 London Heights San Antonio, TX Phone: (210)

Floors Walls Roofs. Jablite Premium board Jablite board. APPLICATION: Internally Lined Pitched Roof PRODUCTS: Vencel Resil Limited

GENERAL INSTALLATION GUIDELINES

Weatherproofing & Sealing Systems

Chapter 7. Roof Framing

Cladding Attachment Solutions for Exterior Insulated Commercial Walls

VESDURA VINYL PLANKS 7.5MM WPC CLICK LOCK - AMERICANA COLLECTION

Kingspan Day-Lite Klick

Loadbearing timber joist floors

MATERIAL & COMPONENT SPECIFICATION DATE: 1 ST FEBRUARY 2015 ISSUE NO: 19

Fire safety issues with balconies

Majrex. System Guidelines For Air Barrier and Vapor Control Installation

AIR BARRIER DESIGN PRINCIPLES AN OVERVIEW.

Standard specification for the application of Danosa Two-Layer waterproof roofing membrane to plywood & concrete surfaces.

The Celotex Handy Guide

BDA Agrément BAW /01/C

General. Moisture. Secondary Water-Resistive Barrier. Storage. Gaps & Sealants. Stud Spacing. Flashing, Windows, Doors & Openings

Vario XtraSafe. Airtightness and moisture management system.

PREFA Aluminiumprodukte GmbH Page 1 of 21

Air and Vapor Barrier 3015

INSTALLATION INSTRUCTIONS FOR WICANDERS HYDROCORK

Insulation. Second Issue November Quick Guide. Building a better Kingdom together. Low Energy Low Carbon Buildings

CHAPTER 1: OVERVIEW OF ENERGY EFFICIENT CONSTRUCTION

ThermaSlim Aerogel Magnesium Oxide Board Internal Wall Insulation (IWI) Board

Vertigo Cladding Board

Passive House Project documentation

Warmer Roof. Transforming conservatory roofs. WarmerRoof

Details for Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses

Transcription:

ASSEMBLY INSTRUCTION Hunton Windtight 12 TG 2002 HUNTOIN Windtight

Storage Windtight panels must be stored dry and be dry when fitted. Before fitting, the panels should be conditioned where necessary so that the moisture in them is more or less equivalent to the equilibrium humidity of the climate in which they are to be used. Packaging which has been opened must be protected from precipitation when being stored. Damaged panels should not be used. Hunton Tape or similar may be used for minor touching up. 1 Installation Maximum distance between centres of uprights, beams, barriers, etc. must be 600 mm. All panel edges must be supported, and plank trusses must be placed under any transverse joints. The panel joints must be centred as much as possible on the plank trusses so that nails can be accommodated. The panels must be fitted 2 3 mm apart. Windtight with seams must be used in the case of upright dimensions of less than 48 mm. The panels are secured using 2.8 45 mm roof nails at a 100 mm distance to centre along the panel edges and 250 mm to centre along the middle of the panels in order to ensure sufficient wind bracing and sealing. Alternatively, corrosion-proofed staples can be used with a minimum width of 1.8 mm and a back 20 mm long and a minimum leg length of 28 mm with an adhesive coating. Staples are secured with the back parallel to the edge of the panel. Distance to centre the same as for roof nails. Nails and staples must be secured so that their heads/backs lie flat against the surface of the panels, but without breaking the sealing layer on the panels. D1. Nail distance 2 Clamping of seams All panel seams must be secured using ties in order to ensure good air tightness. Use of slats a minimum of 23x36 mm in size, or similar, is recommended. Battening between Windtight and the outer cladding must be at least 20 mm. In instances where vertical outer cladding is intended for use, thinner ties (e.g. 11x36 mm) may be used. Here, horizontal slats have to be fitted on the outside which are thick enough for the vertical classing. For additional securing in seams between panels, it is possible to use Hunton Tape and primer or breathable cardboard strips which are stuck under the slats. D2. Securing seams without cardboard D3. Securing seams with tape or cardboard

3 Corner solution It is also possible in corners to use tape or cardboard strips to provide additional security against air leaks. Panel seams must be nailed at a distance to the centre of 100 mm and be secured using slats. D4. Corner solution 4 Lead-throughs Lead-throughs must be planned and executed in a manner which will not destroy the seal of the barrier layers. Lead-throughs through the outer structure should be kept to a minimum and should be planned in advance so that it is possible to achieve a good seal. Some critical details: Ventilation ducts and facilities must be placed within the sealing and insulating layer for energy-related reasons as well. Duct lead-throughs must be sealed carefully. All lead-throughs for electricity and HVAC must be planned when conduits and sleeves are fitted. Balconies should not be constructed with protruding beams. D5. Blocking around lead-throughs In the case of all lead-throughs in Windtight, it is necessary to place blocks around the lead-through to ensure that the panel seams are secured sufficiently. In Windtight panels, you just have to make the necessary holes for the lead-through and nail the panel to the block behind it, with a 100 mm distance to centre. It is a good idea to secure around the lead-through with Hunton Tape and primer or similar. In addition, you should secure around the lead-through, as shown in Detail 7, for optimum securing of the air teal. Hunton Tape and primer are extremely adhesive and allow you to secure against air leaks with ease at critical points. D6. Jointing around lead-throughs D7. Securing lead-throughs 5 Transition between walls To reduce cold bridges at the transition point between a wall and a tie, Windtight can be moved down slightly on the top of the wall as long as you place a cardboard base at the back so that the timber does not come into contact with the concrete. D7. Transition between walls

6 Window detail with tape All panel seams around windows must be secured with nails or similar at a distance of 100 mm from the centre. We also recommend that you use tape for extra security. All panel seams/ends must be secured using slats. Windows are installed according to the manufacturer s own instructions. D8. Window detail with cardboard 7 Transition between wall and ceiling with protruding barrier Details around the transition between wall and ceiling are important to ensure that cold bridges and air leaks are kept to a minimum. At the point where the foot of the barrier protrudes past the wall, you can cut out the dimension from Windtight and then move the panel up to the top of the block as shown in Detail 10. The block between barriers is recommended as this also ensures a good securing function for the ceiling. This will allow you to secure the panels to the block properly and make a joint between the panel and the protruding barrier. All Windtight seams and ends must be nailed at a distance of 100 mm from the centre and secured using slats. As an alternative, you can use loose protrusions as shown in Detail 10. Detail 9 shows how you can easily achieve a good air seal and keep cold bridges to a minimum. Hunton Sarket has been used for the ceiling, where aeration takes place above the panels only. D9. Transition between wall and ceiling with protruding barrier 8 Transition between wall and ceiling with loose protrusion Loose protrusions can be created in many different ways, but the principal shown in Detail 9 essentially demonstrates how Windtight is applied to Hunton Sarket in order to ensure a good seal. This is done according to more or less the same principle if other types of ceiling are used. D10. Transition between wall and ceiling with loose protrusion

Windproofing in general Wind barriers have a number of functions, both during construction and after the building has been commissioned. Before external cladding is fitted, wind barriers must help to seal the building and protect its insulation and the rooms inside from rain and wind. Hunton also has sufficient mechanical strength to provide the building with wind bracing (for small buildings of up to two storeys). Wind barriers also have to be able to allow moisture to pass out of the structure, and so they have to have the least moisture resistance possible. Once the structure is complete and has been commissioned, the wind barrier should protect the walls from any rainwater which penetrates the cladding and prevents heat loss due to air leaking out. A well fitted wind barrier is crucial for achieving the intended heat insulation for a wall structure. Windtight have led the market for more than 35 years and their products have all the qualities a good wind barrier requires. The Norwegian Technical Regulation for the Planning and Building Act (TEK) was amended in 2007. This defines more stringent demands stating that the air tightness of new detached houses must be kept within a lower limit of 2.5 air exchanges per hour. In practice, this means that the implementation of the wind barrier and vapour barrier layers should be considered very carefully during fitting. The U-value of walls can also be influenced by Windtight. The requirements laid down in TEK 2007 state that the U-value must be, on average, 0.18W/(m 2 K) for the building element (energy measures model). As can be seen from the table below, the use of Windtight provides a contribution of 0.01 W/(m 2 K). Estimated U-value (W/(m 2 K)) Outer wall with timber framework and Windtight wind barrier 1 2 Upright dimensions D (mm) 36 x 198 48 x 198 36 x 223 48 x 223 36 x (148 + 98) 48 x (148 + 98) 36 x (148 + 148) 48 x (148 + 148) insulation class thermal conductivity, γ, (W/mK) 0,034 0,037 0,040 0,043 0,18 0,16 0,17 0,13 0,14 0,22 0,20 0,17 0,18 0,14 0,15 0,22 0,23 0,20 0,18 0,15 0,16 0,23 0,24 0,22 0,20 0,16 0,17 1 If a wind barrier made from plaster, film or similar is used, the U-value has to be increased by 0.01W/m 2 K). 2 For outer walls with cross bracing, it is possible to reduce the U-value by a further 0.01W/(m 2 K) for all upright dimensions. Estimated U-value (W/(m²K)) Outer wall with I-Beam timber framework and 12 mm Windtight wind barrier 1 Upright dimensions Ref. NBI sheet 471.012, table 22. Insulation class (W/mK) mm 0,034 0,037 0,040 200 0,18 220 0,17 0,18 240 0,15 0,16 0,17 250 0,15 0,16 0,17 300 0,12 0,13 0,14 1 For wind barriers made from film, plasterboard or similar, the U-value has to be increased by 0.01 W/(m²K)

Dette papiret er 100% resirkulert June 2013 idetrykk.no PEFC/03-31-21 See www.hunton.no or contact us on +47 61 13 47 00, fax +47 61 13 47 10 or hunton@hunton.no