An Opening Argument: The Controversy Over Floodshields & the Protection of Glass Storefronts & Curtain Walls

Similar documents
ARCHITECTURAL APPLICATIONS OF WATER PROTECTION SYSTEMS

BUILDING A STRUCTURE IN THE FLOODPLAIN. IMPORTANT REQUIREMENTS Of Warren County Floodplain Management Ordinance

FLOODPLAIN DEVELOPMENT AND BUILDING ORDINANCE

Protecting Building Utilities From Flood Damage

ELEVATION CERTIFICATE

Basements and Crawlspaces: What s the Difference, and Who Cares?

Greg Wilson FEMA Building Science Rebecca Quinn, CFM RCQuinn Consulting, Inc.

CHAPTER 6 BUILDING REGULATIONS ARTICLE I FLOOD PLAIN CODE

Showing Only Sections Changed 6 th Edition FBC (2017) from 5 th Edition FBC (2015) [changes shown with underline and strike-through]

Port of New Orleans Design Resiliency Manual 2013

N.J.A.C. 5:23-2. Administrative and Enforcement Provisions

Commercial Tax Abatement

DLCD ACKNOWLEDGMENT or DEADLINE TO APPEAL: Monday, November 15, 2010

SECTION 11: REGULATORY FLOODWAYS

ELEVATION CERTIFICATE

2012 IBC Flood Provisions

June 7, 2016 request for formal interpretation of Section 2.3 (Combining Factored Loads Using Strength Design) of ASCE/SEI 7-10.

Building Safe Structures in Flood Zones

MEMO OF REVIEW FOR CORRECTNESS AND COMPLETION

STORMWATER AND EROSION CONTROL PERMIT

SITE PLAN AND ARCHITECTURAL REVIEW APPLICATION

Freight Street Development Strategy

Increasing the Coastal Resilience of Vulnerable Wastewater Infrastructure on Cape Cod and the Islands Two Case Studies

FEMA P-1019 Emergency Power Systems for Critical Facilities. ASFPM May 4, 2017 David K Low, PE DK Low & Associates

GREEN BROOK FLOOD CONTROL PROJECT FLOODPLAIN MANAGEMENT PLAN

SAVANNAH TRIMS st STREET N., SUITE 4 LAKE PARK, FLORIDA

2/13/2013. Section 1 - A Zone Building Rating. Section 2 - V Zone Building Rating. Section 3 Rating procedure. Section 4 A Zone Examples

Disaster Damage Prevention Planning

Port of Camas/Washougal Levee Recertification and Engineering Analysis Request for Proposal May 3, 2011

Civil Engineering and Architecture Detailed and Performance Objective Outline

Add Flood Provisions to the 2010 FBC, Building

Flood Damage Prevention Ordinance. Town of Hampton - South Carolina

TOWN OF ROTTERDAM RESIDENTIAL BUILDING PERMIT APPLICATION Ext. 395 Needed to Obtain Permit:

December 20, 2013 Furman Center Retrofit Solutions Workshop! Retrofit Solutions Workshop Goals

CITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT. Submittal Requirements

Storm Preparedness & Hazard Mitigation for Post-Sandy Red Hook, Brooklyn, NY Deborah Mills, CFM Dewberry Consultants, LLC.

RESIDENTIAL BUILDING PLAN REQUIREMENTS

Codifying Resiliency

Condominium Project Profile and General Review Form

Flood Mitigation Solutions

2010 Florida Building Code, Building

Neighborhood Traditional Single-Family District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

Johns Hopkins Graduate Student Housing. Thesis Proposal. 929 North Wolfe Street Baltimore, Maryland Brad Oliver Structural Advisor: Professor Memari

PT Slab Deflections. What is acceptable? By Douglas Sarkkinen, PE,SE Senior Structural Engineer Otak, Inc PTI Annual Conference, Kansas City, MO

Ordinance No July 1, 2016

Chapter 1. Introduction

Appendix C. Alternative Mitigation Actions

JEFFERSON PARISH SHERIF S OFFICE

Town of Waterford. Municipal Infrastructure Resilience Project Sewer Pump Station Assessment and Adaptation Final Report

421 FLOOD PLAIN AND DRAINAGE HAZARD AREA DEVELOPMENT Lands Subject to Flood Plain and Drainage Hazard Area Standards

Corridor Residential Traditional District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

Involving Stakeholders in the Professional s Design and Construction Process

Place Vanier Édifice AEFO

Public Hearing January 13, Request Conditional Use Permit (Auto Repair Garage) Staff Planner Carolyn A.K. Smith

BUILDING CODES & DESIGN CRITERIA

ARTICLE 4 SUPPLEMENTARY PROVISIONS

RESIDENTIAL BUILDING PERMIT

PERMIT APPLICATION REQUIREMENTS NEW COMMERCIAL BUILDING/CONSTRUCTION CODES USED: CURRENT ADOPTED FLORIDA BUILDING CODE AND NEC

SECTION 6: MITIGATION STRATEGY

ARCH 5901 A02 Office Building Program FALL 2015

NEW CASTLE CONSERVATION DISTRICT. through. (Name of Municipality) PLAN REVIEW APPLICATION DRAINAGE, STORMWATER MANAGEMENT, EROSION & SEDIMENT CONTROL

2. Does not require, involve or include any additions to, or repair or modification of, the existing foundation.

Neighborhood Suburban Single-Family District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

Title 16 ENVIRONMENTAL AND RESOURCE PROTECTION

SECTION WATERTIGHT FLOOD PLANKS. A. ASTM A 36 - Standard Specification for Carbon Structural Steel.

SECTION ALUMINUM WINDOWS

Soil Erosion and Sedimentation Control Compliance Form

Architectural Review Board Application Information & Criteria

Received by:* Date Received:* Zoning Approval:* Date:* PERMIT#:* *ZONING: *SETBACKS: FRONT ft/ SIDE ft/ REAR ft *FLOOD ZONE:

Inspection of New One- and Two- Family Dwellings

ARTICLE 987. PD 987. PD 987 was established by Ordinance No , passed by the Dallas City Council on June 14, (Ord.

4. Construction Analysis Façade Sequencing

County Council Of Howard County, Maryland

Data Collection Report draft

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures

PRESCRIPTIVE COMPLIANCE METHOD

FACILITY DESIGN PLAN FOR HARDING HALL RENOVATION AND ADDITION SOUTH DAKOTA STATE UNIVERSITY DATE: March 29, 2017

Residential Building Permit Application

LEED v4 Building Design and Construction Quiz #8 EQ

Building Technology III New York City College of Technology. Course Day 13 Revit Day 05 (Project Day 2)

Chapel House- Design Process- Envelope and Energy savings

Practice Bulletin No

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

Practical Needs and Approaches for Water Resources Adaptation to Climate Uncertainty

SPACE TYPE: OUTSIDE PARKING (STRUCTURE)

r e s i d e n t i a l o u t s i d e v i l l a g e c e n t e r

Neighborhood Suburban Single-Family District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

Lessons [being] learnt 2016 Flood in Cedar Rapids. Sandy Pumphrey Project Engineer II Flood Mitigation

A/E Design Deliverable Checklist

B-2 COMMUNITY COMMERCIAL BUSINESS DISTRICT. Uses allowed in the B-2 Community Commercial Business District are subject to the following conditions:

City of Jacksonville Development Guide Building Permits

SPECIFICATION FOR Aluminium alloy windows

BC BUILDING CODE ERRATA

Permit Requirements: Building Codes: The City of Clanton has adopted the following codes which are enforced by the Building Department:

HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS

Ultra-Thin Prestressed Precast Panel Technology

Meeting Residential Energy. Construction. Copyright Materials. Loren Ross, P.E. Manager, Engineering Research American Wood Council

RESIDENTIAL BUILDING PERMIT PROCEDURES

Transcription:

An Opening Argument: The Controversy Over Floodshields & the Protection of Glass Storefronts & Curtain Walls James P Colgate AIA, Esq, CFM Bryan Cave LLP Partner, Land Use Team Real Estate Client Service Group New York, NY Association of State Floodplain Managers Annual Conference May 2, 2017 Kansas City, MO 1

2 global law firm with approximately 1,000 highly skilled lawyers approximately 150 lawyers in real estate client service group 27 offices across North America, Europe and Asia diversified transaction and litigation practice serving clients in key business and financial markets around the world client base that includes publicly held multinational corporations, large and mid-sized privately held companies, emerging companies, notfor-profit organizations, government entities and individuals

What is Dry Floodproofing? 3 Dry floodproofing (44 CF 603(c)(3): the structure is watertight with walls substantially impermeable to the passage of water 3

What is Dry Floodproofing? 4 Dry floodproofing (44 CF 603(c)(3): the structure is watertight with walls substantially impermeable to the passage of water 4

Architectural Styles, glass 5 Hardwick Hall, more glass than wall c 1597, Chesterfield 5

Architectural Styles, glass 6 Erazmus Pavilion, no wall at all c 2013, Rotterdam 6

Architectural Styles, glass 7 Glass Farm, glass imitates wall c 2013, Schijndel 7

Architectural Styles, glass 8 Fulton Street Transit Center New York City, 2014 8

Architectural Styles, glass 9 Main Street revitalizations, USA Show windows 9

Regulatory Framework 10 Source Guidance 44 CFR 603 FEMA TB 3 FEMA P 936 References ASCE 24 References IBC References USACE 1995 International Building Code Includes ASCE 24-14 Local Codes eg, New York City Building Code based on IBC IBC Commentary ASCE 24-14 Annex ASCE Interpretations 10

44 CFR 603 11 Community Obligations for A-Zones: Building Sites: New construction Substantial Improvements Subdivisions Flood damage generally Utilities Drainage Water Supply and Sanitary Sewer Systems Recreational Vehicles 11

44 CFR 603 12 Community Obligations for A-Zones: Building Sites: New construction Substantial Improvements Subdivisions Flood damage generally Utilities Drainage Water Supply and Sanitary Sewer Systems Recreational Vehicles Dry floodproofing for nonresidential buildings 12

44 CFR 603 (must a structure have walls?) 13 13 Dry floodproofing 44 CF 603 (c) [T]he community shall: (3) Require that all new construction and substantial improvements of non-residential structures within Zones A1-30, AE and AH zones on the community's firm (i) [elevate] or, (ii) together with attendant utility and sanitary facilities, be designed so that below the base flood level the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy;

44 CFR 603 14 14 Dry floodproofing 44 CF 603 (c) [T]he community shall: (4) Provide that where a non-residential structure is intended to be made watertight below the base flood level, (i) a registered professional engineer or architect shall develop and/or review structural design, specifications, and plans for the construction, and shall certify that the design and methods of construction are in accordance with accepted standards of practice for meeting the applicable provisions of paragraph (c)(3)(ii) or (c)(8)(ii) of this section, and (ii) a record of such certificates ;

FEMA Technical Bulletin TB 3-93 15 The building must be watertight (ie, floodwaters must not enter the building envelope) The building s walls must be substantially impermeable to the passage of water 15

FEMA Technical Bulletin TB 3-93 16 16 Floodproofing components for an individual building may also include floodwalls, small localized levees, or berms around buildings However, such components, because they are not part of the building itself, are generally not credited for the flood insurance rating of a building under the NFIP and are therefore not detailed within this bulletin

FEMA PUBLICATION P-936-13 17 Chapter 3: Dry floodproofing Continuous impermeable walls Flood shields for openings in exterior walls Chapter 4: Floodwalls and Levees Barriers between the building and floodwaters 17

FEMA PUBLICATION P-936-13 18 Chapter 3: Dry floodproofing Continuous impermeable walls Flood shields for openings in exterior walls Chapter 4: Floodwalls and Levees Barriers between the building and floodwaters 18

FEMA PUBLICATION P-936-13 19 Chapter 3: Dry floodproofing Dry floodproofing A combination of measures that results in a structure, including the attendant utilities and equipment, being watertight with all elements substantially impermeable to the entrance of floodwater and with structural components having the capacity to resist flood loads Figure 3-10 Types of flood shields 19

FEMA PUBLICATION P-936-13 20 Chapter 3: Dry floodproofing Must be designed so the structure is watertight below the BFE with walls substantially impermeable to the passage of floodwaters Figure 3-10 Types of flood shields 20

FEMA PUBLICATION P-936-13 21 Chapter 3: Dry floodproofing Dry floodproofing A combination of measures that results in a structure, including the attendant utilities and equipment, being watertight with all elements substantially impermeable to the entrance of floodwater and with structural components having the capacity to resist flood loads Figure 3-10 Types of flood shields 21

FEMA PUBLICATION P-936-13 22 Chapter 3: Dry floodproofing The standards of practice require that the building, together with attendant utility and sanitary facilities, be designed so that it is watertight below the BFE, with walls substantially impermeable to the passage of water and with structural components that are capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy associated with the design flood event Figure 3-10 Types of flood shields 22

Regulatory Framework FEMA P-936 23 Chapter 4: Floodwalls and Levees Floodwall Constructed barrier of flooddamage-resistant materials to keep water away from or out of a specified area Floodwalls surround a building or area and are off-set from the exterior walls of the building Levee Manmade barrier, usually an earthen embankment, designed and constructed in accordance with sound engineering practices to contain, control, or divert the flow of water so as to provide protection from temporary flooding 23

FEMA PUBLICATION P-936-13 24 Chapter 4: Floodwalls and Levees Do not satisfy NFIP new construction/substantial improvement standards unless certified Often installed as retrofits/pre-firm facilities 24

IBC, ASCE 24-14 25 Definitions Dry Floodproofing A combination of measures that results in a structure, including the attendant utilities and equipment, being watertight with all elements substantially impermeable and with structural components having the capacity to resist flood loads Shield Removable or permanent substantially impermeable protective cover for an opening in a structure below the DFE, used in dry floodproofing the structure 25

IBC, ASCE 24-14 26 ASCE 24 Section 622 Dry-floodproofed areas of structures shall [b]e designed and constructed so that any area below the [DFE], together with attendant utilities, equipment, and sanitary facilities, is flood resistant with walls that are substantially impermeable to the passage of water Walls, floors, and flood shields shall be designed and constructed to resist hydrostatic, hydrodynamic, and other flood-related loads, including the effects of buoyancy resulting from flooding to the DFE 26

IBC, ASCE 24-14 27 Appendix C142: Flood Control Structure/Flood Protective Works Barriers that keep waters away from an area 27

ASCE 24 Standards Committee Formal Interpretation 11/29/16 28 Question: Does a building located in an AE- Zone with permeable exterior walls below DFE (ie glass curtain walls supported by impermeable reinforced concrete stem wall) meet the dry floodproofing requirements of Section 622 when removable flood shields are used as a component of the exterior building façade to render the permeable exterior wall impermeable from grade to the design flood elevation along the entire length of the building s façades? 28

ASCE 24 Standards Committee Formal Interpretation 11/29/16 29 29

ASCE 24 Standards Committee Formal Interpretation 11/29/16 30 30

ASCE 24 Standards Committee Formal Interpretation 11/29/16 31 31 Answer: Yes, the removable flood shields described and shown in the request meet the dry floodproofing requirements of ASCE 24-14, provided the following conditions are met: 1 when installed, the shields are close to and attached to the building façade, 2 the shield attachment is via guides, fasteners or supports that are permanent parts of the building façade, and 3 the building and flood shields meet all other dry floodproofing requirements, restrictions and limitations of chapter 6

BUILDING NFIP Compliant? IBC/ASCE 24 Compliant? 32 Dry floodproofing? or Flood control structure? 32

NFIP Compliant? IBC/ASCE 24 Compliant? 33 33

NFIP Compliant? IBC/ASCE 24 Compliant? 34 34

NFIP Compliant? IBC/ASCE 24 Compliant? 35 35

NFIP Compliant? IBC/ASCE 24 Compliant? 36 36

NFIP Compliant? IBC/ASCE 24 Compliant? 37 37

NFIP Compliant? IBC/ASCE 24 Compliant? 38 38

NFIP Compliant? IBC/ASCE 24 Compliant? 39 39

FEMA Policy Call 40 FEMA Floodplain Management probably says (?) : dry floodproofing is inherently difficult to accomplish dry floodproofing failures can be catastrophic damage shields should be discouraged as much as possible 40

FEMA Policy Call 41 FEMA Floodplain Management probably says (?) : dry floodproofing is inherently difficult to accomplish dry floodproofing failures can cause catastrophic damage shields should be discouraged as much as possible FEMA Insurance should: have policies that discourage excessive dry floodproofing 41

FEMA Policy Call 42 FEMA Floodplain Management probably says (?) : dry floodproofing is inherently difficult to accomplish dry floodproofing failures can cause catastrophic damage shields should be discouraged as much as possible FEMA Insurance should: have policies that discourage excessive dry floodproofing FEMA Building Sciences should say that 44 CFR 603: does not require a minimum amount of wall requires any provided walls be substantially impermeable to the passage of water requires shields to be integral to the structure to satisfy 44 CFR 603 requires dry floodproofing systems to meet ASCE 24 for all 42 engineering loads and for flood action plans

FEMA Policy Call 43 FEMA Building Sciences should say that 44 CFR 603: does not require a minimum amount of wall requires any provided walls be substantially impermeable to the passage of water requires shields to be integral to the structure to satisfy 44 CFR 603 requires dry floodproofing systems to meet ASCE 24 for all 43 engineering loads and for flood action plans

Insurance Rates for Dry Floodprooing 44 To encourage designs with reduced reliance on shields Examples: Perimeter wall concept: Reduced rates: all walls (no openings) Increased rates: some openings Significantly increased rates: lots of openings (% of wall to opening) Performance standard concept: Payout of claim only when the actual flood level exceeds DFE No payout for failure of dry floodproofing where actual level of flood is below DFE 44

An Opening Argument: The Controversy Over Floodshields & the Protection of Glass Storefronts & Curtain Walls James P Colgate AIA, Esq, CFM Bryan Cave LLP Partner, Land Use Team Real Estate Client Service Group New York, NY Association of State Floodplain Managers Annual Conference May 2, 2017 Kansas City, MO 45