DSC differential scanning calorimeter (DSC)

Similar documents
Differential Scanning Calorimetry DSC 200 F3

THERMAL DIFFUSIVITY THERMAL CONDUCTIVITY

Thermal Diffusivity - Thermal Conductivity LFA 447

Introduction to TG/DTA/DSC. Thermal Processing Technology Center Illinois Institute of Technology

SEMATECH Provisional Test Method for Evaluating Bulk Polymer Samples of UPW Distribution System Components (DSC and TGA Methods)

S2 RANGER LE: Analysis of Light Elements in Cement, Slags and Feldspar

Brinell Rockwell Vickers. Hardness Tester (Manual)

Thermal Analysis Excellence

SURFACE TEMPERATURE SENSORS

Nova Geração de Instrumentos de Análise Térmica

Analyzing & Testing. Differential Scanning Calorimetry. Method, Technique, Applications DSC 204 F1. Leading Thermal Analysis

DIFFERENTIAL SCANNING CALORIMETER. Chip-DSC 100 Chip-DSC 10

New Developments in Measuring Low Silicon in Process Piping Using Handheld X-ray Fluorescence (XRF)

Welding Processes. Consumable Electrode. Non-Consumable Electrode. High Energy Beam. Fusion Welding Processes. SMAW Shielded Metal Arc Welding

Differential Scanning Calorimetry DSC 404 F1

Ultra High Molecular Weight Polyethylene (UHMWPE)

Thermal Analysis. Application Handbook. Thermal Analysis of Polymers Selected Applications

TA INSTRUMENTS DIFFERENTIAL SCANNING CALORIMETERS

PHOTOVOLTAIC SOLAR ENERGY POLYCRYSTALLINE MODULES - SI-ESF-M-P156-60

PORTABLE COATING THICKNESS GAUGE

Part 1: General principles

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD. ANSI/SCTE (Formerly IPS SP 100)

WELDING Topic and Contents Hours Marks

Label Tape FAQs and Technical Information Pertaining to Brother Label Printers PT-9700PC and PT-9800PCN

New Advances using Handheld XRF Technology for the Prevention of Flow-Accelerated Corrosion (FAC)

Analyzing & Testing. Guarded Hot Plate - GHP. Method, Instrumentation, Applications. GHP 456 Titan. Leading Thermal Analysis

Cal-Chip Electronics, Incorporated Thick Film Chip Resistors - RM Series

Bonded Neo Magnetization Guide

Standard Test Method for Transition Temperatures of Polymers By Differential Scanning Calorimetry 1

1/31/ Plastics Processing. Thermoplastics (Tampere)

Standard Test Method for Oxidative-Induction Time of Polyolefins by Differential Scanning Calorimetry 1

Furnaces for Research and Laboratory. Testing Drying Ashing Tempering Preheating Sintering Firing Annealing

Induction Heating. Jean Callebaut, Laborelec. 1 Introduction Physical principles Induction Installations... 5

Coating Thickness Meter Data Sheet / Instructions

adaptable 2014 CONCEPT MODULAR PREFAB - MODULI ABITATIVI PREFABBRICATI

SANY ASPHALT BATCHING PLANT

Materials Engineering PTT 110

Trust but verify: Ensure product quality at all stages of production

Understanding Coating Thickness Measurement Helmut Fischer

ELECTRICAL RESISTIVITY AS A FUNCTION OF TEMPERATURE

Low Temperature Testers

Carbon / Sulfur Analyzers

Sound-absorbing and sound-insulating barriers

SERVO-HYDRAULIC UNIVERSAL TESTING MACHINE SERIES A

onlinecomponents.com Prototyping : The Process

Optimizing Strain Gage Excitation Levels

ISO 4898 INTERNATIONAL STANDARD. Rigid cellular plastics Thermal insulation products for buildings Specifications

ECO INSTRUMENT (NS M)

Sensortherm. Digital Pyrometer. Temperature Measurement and Control. com

Component Palladium Lead Finish - Specification Approved by Executive Board 1997-xx-xx August 22 Version

Vickers Hardness Tester (Automatic Turret)

Electrically insulated bearings from SKF

ISO INTERNATIONAL STANDARD

Heat Transfer in Polymers

Collected Applications Thermal Analysis ELASTOMERS. Volume C

Drop Weight Impact Testing Machine DIT183E 1800J

High Heating Rate DSC

Novel concept of rechargeable battery using iron oxide nanorods. anode and nickel hydroxide cathode in aqueous electrolyte

Sandwich Panel Production Line. Allbest Creative Development Ltd. (ALLBEST)

Thermal Analysis Excellence

COATING THICKNESS MEASURING

IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor

Prevention of Condensation on Conduits that Penetrate Insulated Metal Panel

TYPE TEST PROTOCOL DESCRIPTION. Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus ENVIRONMENTAL PERFORMANCE

Advancing with Technology

Fpollutant-free zero air for analytical

Plastics Differential scanning calorimetry (DSC) Part 2: Determination of glass transition temperature and glass transition step height

Analyzing & Testing. DSC 214 Polyma. Surprisingly Easy The New All-Inclusive Product Package for DSC

Accessories for Differential Scanning Calorimeters and Thermobalances

The principle Of Tungsten Inert Gas (TIG) Welding Process

PART MATERIAL REMARK Metal Case with Pig-tail. Brass (Metal Case) Copper (Pig-tail) Star Contact Copper Silver Plated

NIR Checkmaster Near-infrared spectroscopy On-line analysis of active ingredients during tablet production

Thermal and Rheological Evaluation of Pharmaceutical Excipients for Hot Melt Extrusion

Part 1: General principles

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

PHOTOVOLTAIC SOLAR ENERGY POLYCRYSTALLINE MODULES - SI-ESF-M-BIPV-SM-P125-36

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

Atmosphere Effect on Soldering of Flip Chip Assemblies. C. C. Dong Air Products and Chemicals, Inc. U.S.A.

MuShield s High Permeability Magnetic Shielding per ASTM A753 Alloy Type 4

Thermal Evaporation. Theory

Understanding Extrusion

FITOCLIMA WALK-IN STABILITY

Hitachi Anisotropic Conductive Film ANISOLM AC-7106U

One-part moisture-curing elastic adhesive meeting UL94V-0 flammability standard

Thermal Analysis Excellence

Application of computed tomography for an analysis of composite with fine dispersive reinforcement made of the Fe 65 Co 10 Ni 3 W 2 B 20 alloy

WE11S GMA (MIG) Fillet Weld

Low CTE / High Tg FR-4 with High Heat Resistance

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

WE01A GMA (MIG) Plug Weld

Chinese Insulation and Energy Saving Material Industry Development Plan for the 12th Five-year Program

Black 1:1 Epoxy, Encapsulating & Potting Compound

HOME APPLIANCES START WITH SMART SOLUTIONS

nicrom e l e c t r o n i c

Study of the Replica of Rossi s High Temperature Generator. New results

MonTech RP 3000 Rapid Plastimeter for Polymers and Natural Rubber

XRF DRIFT MONITORS DATA CALIBRATION MATERIAL

PRELIMINARY. HTHA (Z1-Foil)

HTHA (Z1-Foil) Vishay Foil Resistors

Sound Absorbing Acoustic Materials

Transcription:

THERMAL ANALYZERS DSC- 2200 differential scanning calorimeter (DSC) Product introduction: DSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control. DSC research and development includes the following field: glass transition temperature, melting point, cold crystallization, crystallization, phase transition, oxidation induction time (OIT). Main Features: 1. New designed oven structure ensures high resolution and good stability of base line; 2. Digital air flow meter may control the air flow rate accurately; the test data can be recorded into the database directly; 3. The instrument is bilateral control, may be controlled by both main frame and software. User-friendly interface, easy operation. Technical parameters: 1. DSC range: 0~±500mW 2. Temperature range: room temperature ~ 800 air-cooled - 50 ~ 800 semiconductor refrigeration * - 100 ~ 800 liquid nitrogen refrigeration * 3. Heating rate: 1 ~ 80 / min 4. Cooling rate * : 1 ~ 20 / min 5. Temperature resolution: 0.1 6. Temperature fluctuations: ±0.1 7. Temperature repeatability: ±0.1

8. DSC noise: 0.01µW 9. DSC resolution: 0.01µW 10. DSC accuracy: 0.1 u W 11. DSC sensitivity: 0.1 u W 12. Control Mode: Rising temperature, constant temperature, cooling temperature (full automatic programmed control) 13. Curve scanning: Rising scan, *cooling scan 14. Atmosphere control: Embedded digital flow meter & Software control 15. Display: liquid crystal display (LCD) 16. Data interface: RS232 interface 17. Parameter standard: equipped with standard material (indium, tin, and lead), the user may correct temperature and heat enthalpy 18. Note: * for selecting projects, all technical indicators can be adjusted according to customers' demand ============================================================================================ DSC-2335 differential scanning calorimeter (DSC) Product introduction: Measure and research the following characteristics of material: Melting and crystallization, glass transition, thermal stability,oxidation induction period OIT, the polycrystalline compatibility, reaction heat, enthalpy and melting point of material, thermal stability, crystallinity, phase transition, specific heat, the liquid and crystal changes, curing degree, reaction kinetics, purity, identification of materials, etc. Technical parameters: 1. DSC range: 0~±500mW 2. Temperature range: room temperature ~ 800 air-cooled - 30 ~ 800 semiconductor refrigeration * - 100 ~ 800 liquid nitrogen refrigeration * 3. Heating rate: 1 ~ 80 / min

4. Cooling rate * : 1 ~ 20 / min 5. Temperature resolution: 0.1 6. Temperature fluctuations: ±0.1 7. Temperature repeatability: ±0.1 8. DSC noise: 0.01µW 9. DSC resolution: 0.01µW 10. DSC accuracy: 0.1 u W 11. DSC sensitivity: 0.1 u W 12. Temperature-control and means: Rising temperature, cooling temperature, constant temperature (full automatic programmed control) 13. Curve scanning: warming scanning, cooling scanning * 14. The atmosphere control: static or dynamic atmosphere, gas flow control device 15. Display: Big LCD screen (LCD) 16. Data interface: RS232 interface, special software (not regular free upgrades) 17. Parameter standard: With standard materials (indium, tin, lead), User can correct the temperature and heat content according to rquirements 18. Remarks: * the selective matching items, All of the technical specifications can be adjusted according to customers requirements ============================================================================================ M icro- DSC( micro differential scanning calorimeter) Product introduction: Trace heat meter is a new kind of analysis instruments showing that the stability of samples changes with temperature. Our company self-developed thermal analyzer series products are mainly oriented to industrial users, scientific research and teaching,widely used in all kinds of materials and product research and development in chemical field,process optimization and new quality inspection, etc,

Technical parameters: 1. Temperature Range: - 10 ~ 200 2. Scanning rate: 0.01 ~ 10 / min 3. Control mode: Rising temperature, Cooling temperature, Constant temperature (automatic control), 4. Display: characters liquid crystal display (LCD) 5. Output means: the microcomputer system, printers 6. Curve depicting: supporting intelligent software, realizing automatic recording curve, automatically printing experiment report 7. Work Power: AC220V 50Hz 8. Selecting brand computers:17-inch LCD 512M RAM 80G hard disk 9. Provide irregularly software free upgrades and tracking after-sales service. 10. Provide one year consumables. ============================================================================================ TGA- 2100D thermo gravimetric analyzer Product introduction: Thermo gravimetric analysis (TGA) is in TG, temperature, the temperature or cooling process, observe the quality with temperature or the change of time, the purpose is to study material thermal stability and components. Widely used in plastic, rubber, coating, drugs, catalyst, inorganic materials, metal materials and composites fields of research and development, optimizing process and quality control Measurement and research material following characteristics: Thermal stability, decomposing process, adsorption and desorption, oxidation and reduction, ingredients quantitative analysis, additives and filler influence, moisture and volatiles, reaction kinetics. Technical parameters: 1. Temperature range: Room temperature ~1150 (Can be extended to 1350 ) 2. Temperature resolution: 0.1

3. Temperature fluctuation: ±0.1 4. Heating rate: 1 ~ 80 / min 5. Cooling rate * : 1 ~ 20 / min optional cooling system 6. Temperature control mode: Rising temperature, Cooling temperature, Constant temperature 7. The cooling time: 15min (1000 ~ 100 ) 8. Balance measuring scope: 1mg~2g (Can be extended to 5g) 9. Resolution: 0.1 u g 10. Constant temperature and time: 0 ~ 300min (set arbitrarily) 11. Display: characters liquid crystal display (LCD) 12. Atmosphere: inert, oxidizing, reducible, static and dynamic 13. Atmosphere device: Built-in gas flow meter, including switch two way gas and control flow volume 14. Software: Intelligent software can record TG curves automatically, Processing data and print experimental statements 15. Data interface: RSS - 232 interface, special software (irregularly free upgrades) 16. Power: AC220V 50Hz ========================================================================================= Micro - TGA micro thermo gravimetric analyzer Product introduction: Micro - TGA, micro thermo gravimetric analyzer is mostly used in the field of polymer materials, pharmaceutical, food, organic chemistry, etc. It is a powerful tool for the study of the PCB decomposition temperatures, with 0.1 ug ultra-high weighing resolution, Technical parameters: 1. The temperature range: room temperature - 1000 2. Heating and cooling rate: 0 ~ 60 / min 3. The cooling time: 15min (1000 ~ 100 )

4. Weighing range: 100 mg 5. Weighing resolution: 0.1 u g 6. Measuring atmosphere: inert, oxidizing, reducing, static and dynamic STA 3200 Synchronous thermal analyzer Product introduction: Synchronous thermal analysis combines TGA (Thermogravimetric Analysis) with DTA (Differential Thermal Analysis) or DSC (Differential Scanning Calorimetry), in which we can get the information of TG and DTA or DSC in synchrony using the same sample during the same operation. Measure and research the following characteristics of the materials: DSC: Melting and crystallization, phase change, reaction temperature and heat, heat of combustion and specific heat capacity, etc TG:Thermal stability, decomposition, REDOX, adsorption and adsorption, free water and gesso content, ingredients proportion computation, etc Technical parameters: TGA/DSC STA - 3200 Synchronous thermal analyzer 1. Temperature range: Room temperature ~1150 (Can be extended to 1350 ) 2. Temperature resolution: 0.1 3. Temperature fluctuation: ±0.1 4. Heating rate: 1 ~ 80 / min 5. * Cooling rate: 1 ~ 20 / min optional cooling system 6. Temperature control mode: Rising temperature, Cooling temperature, Constant temperature 7. Constant temperature time : 0~300min Can be set arbitrarily 8. cooling time: 15min(1000 ~100 ) 9. Wide range of weighing: 1mg~2g (Can be extended to 5g)

10. DSC measuring range: 0~±500mW 11. DSC Resolution: 1µW 12. Resolution: 0.1 ug 13. Constant temperature and time: 0 ~ 300min Can be set arbitrarily 14. Display: liquid crystal display (LCD) 15. Atmosphere: Inertia, oxidability, reducibility, static and dynamic 16. Atmosphere device: Built-in gas flow meter, including switch two way gas and control flow volume 17. Software: Intelligent software can record TG curves automatically, Processing data and print experimental statements 18. Data interface: RSS - 232 interface, special software (the software is free upgrades) 19. Work Power: AC220V 50Hz ============================================================================================ CBCT 2350 Carbon Black Content Tester Introduction: 1. This instrument applies to polyethylene, polypropylene and poly DZ3500 Carbon Black Content Tester isobutylene plastics in the determination of the content of carbon. 2. The test result is obtained through the specimen under the nitrogen protection, after analyzing the weight of high temperature decomposition. 3. This apparatus has many advantages such as being easy to use, simple operation, reliable working, accurate measurement, automatic temperature control and so on. Testing standard: GB 13021-1991 GB/T 2951.41-2008 Equipment: 1 Test temperature: room temperature ~1000 2 Temperature adjustment: full-program control (Setting freely) 3 Display: Characters LCD Display 4 Heating tube inner diameter: Ф31 (400±50)mm Overheating protection External temperature probe Flow meter and regulator Silicone connecting pipe Burning boat

============================================================================================ DCL 2501 dielectric constant locator Introduction: Medium loss and dielectric constant is an important physical property of materials such as metal oxide, plank, porcelain (pottery), mica, glass, plastics, etc. Through measurement, the various factors of dielectric loss and dielectric constant can be further understood, providing conditions for improving the properties of materials. The equipment is used for applied research of inorganic metal new material properties in scientific research institutions, schools, factories and other institutions. Technical indicators: 1. Q value range classification: 30, 100, 300, 999, automatic transmission 2. Inductance measuring range: 0.1µH ~ 1H 3. Capacitance measuring scope: 1 ~ 460pF (capacitance measurement more than 460pF see service regulations) 4. Accuracy: + 0.2 pf. 5. Oscillation frequency range: 10 khz ~ 50MHz; 6. Q qualified instructions Pre-set function, Pre-set range: 5 ~ 999. 7. Sample size: Thickness: 2 ± 0.5 mm, long * width: > 30mm * 30mm

TCT, thermal conductivity tester(constant temperature) Introduction: thermal conductivity meter has many advantages, such as large area of the test sample, variety test materials (single materials or composite materials), high precision temperature control, reliable and steady performance, high degree of automation control, convenient operation, etc. Test range Single material: foam plastics (other flat surface insulation material, plate), polyurethane, phenol, urine aldehyde, mineral wool (glass cotton, rock wool, mineral wool), cement wall Composite materials: glass composite CRC, cement enhanced polyphony board, sandwich concrete, fiber glass panel composite plate, paper cellular plate Technical parameters Biggest test pieces size Long * width * thick: 300 * 300 * 50mm The precision of temperature control: 0.05 Resolution: 0.01 The maximum hot plate set temperature: 80 Minimum of cooling-plate set temperature: room temperature

Measuring precision: 3% Coefficient of thermal conductivity measuring range: 0.010 ~ 5.000 w (k.m) Power supply: AC 220V Instrument characteristics: 1. The surface temperature is even and accurate. Using large block purple COINS as Temperature profile board in the design to improve the consistency of the surface temperature of the test sample. 2. Advanced control system. It can control the temperature quickly and steadily. 3. Friendly human-machine interface Both cold and hot plate temperature and heat flux power can be intuitively displayed by large screen LCD. 4. Simple operation. Electric mobile splint and clamping force LCD can be adjusted, Insulation door can be shut down automatically after sample installation in place 5. Intelligent data processing. Highly automated computer data communication and report processing system, Flat thermal conductivity meter has computer communication interface, which can display temperature curve in real time. 6. Automatically generate test report and print. There are test records, data processing and report format in the software, which can issue the experiment report automatically.

X-ray fluorescence analyzer X-ray fluorescence analyzer is a newly developed analyzer of our company, applicable to the cement, mining, stainless steel, aluminum alloy, copper zinc alloy, lead alloy, refractory, ferrosilicon and glass industries, etc Instrument characteristics: 1. Analysis and measure various elements (Allocation any elements from Na to U according to the customer request) at the same time; 2. Can detect the solid, liquid, powder, without complex sample preparation process; 3. Adopt imported SI - PIN detector, with fast analysis speed; 4. High precision, good stability, low failure rate; 5. Adopt multi-level shielding protection, safety and reliable radiation; 6. With rich WINDOWS XP/VISTA application software function, unique advanced analysis method, various charts and tendency chart provided the operator with intuitive support, which is simple to operate, easy to use, and the results can be directly output to Excel, convenient for statistically analyzed. Main technical indices: 1. Multi-function Sample preparation device X fluorescence analyzer Sample preparation device can hold various shape Test samples.

A. sample types: solid, liquid, powder. B. Environment in sample room: air or vacuum. It is automatically controlled by the software, without manual operation. 2. X CRT motivational systems The 50KV system uses low power is high-pressure X-ray generator as excitation source. It is composed by high voltage generator, X-ray generator and control and display system. A. high voltage generator: voltage and current is automatically controlled and displayed by the software. Voltage range: 0V to 50kV continuous adjustable. Current range: 0mA to 1mA continuous adjustable. B. X-ray generator: adopting X-ray tube with low power, natural cooling and high life-span, and choosing target materials according to the actual application. 3. Imported high resolution SI - PIN detector system SI - PIN electric refrigerating high-resolution high count-rate detectors. 4 system software A. operation: WINDOWS XP operating system software, powerful and easy to use. B. function: spectrum shows, analysis element Settings, energy scale, X-ray high-voltage, current automatic control, automatic vacuum control. C. analysis methods: linear fitting, quadratic curves, intensity correction, content, basic parameters calibration method. D. instrument drift automatic revision: ensure the analysis results of the instrument long-term stable