INSPECTIONS OF EXISTING SEPTIC SYSTEMS

Similar documents
Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments

Figure 1. Report of Inspection Process Flowchart.

GRAY WATER SYSTEMS (Reference California Plumbing Code Chapter 16 and 16A) Revised: 6/11/14

INSTALLING A SEPTIC SYSTEM IN LIVINGSTON COUNTY LIVINGSTON COUNTY PUBLIC HEALTH DEPARTMENT 310 TORRANCE AVENUE PONTIAC, IL /

Residential Sewer Backup Prevention Program

SEPTIC TANK CONSTRUCTION GUIDELINES

GUIDELINES FOR SEPTIC SYSTEM DESIGN

GRAY WATER SYSTEMS FOR RESIDENTIAL BUILDINGS

Private Side Sewer Inspections for Sources of Inflow & Infiltration Frequently Asked Questions

Education on Common Household Sewage Treatment Systems Found In Allen County, OH

West Virginia Department of Health & Human Resources Department of Health

Commonwealth of Pennsylvania Department of Environmental Protection (DEP) Bureau of Water Standards and Facility Regulation Harrisburg, PA

On-Site Sewage Disposal Systems. Santa Barbara County Environmental Health Services

Private Sewage Systems Standard of Practice Proposed Revisions

PROPERTY OWNERS ON-LOT SEWAGE MANAGEMENT PROGRAM GUIDANCE

Living With a Septic System A homeowner s guide to basic septic system operation and maintenance

GRAY WATER RECYCLING SYSTEMS

GUIDELINES FOR INSTALLATION OF ON-SITE SEWAGE SYSTEMS

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS

System Design & Installation Manual

SEWAGE PERMIT APPLICATION

INSTRUCTIONS FOR SUBMITTING A COMMERCIAL SEWAGE DISPOSAL PERMIT APPLICATION

Application for a Sewage System Permit

TOILET FACILITIES AND SEWAGE DISPOSAL REGULATIONS

Septic Tank & Drainfield Operation & Maintenance

P U B L I C H E A L T H P R O T E C T I O N. Ministry of Health and Ministry Responsible for Seniors

Webinar: Understanding the California Plumbing Code for Greywater (Gray water) Installations

Geotextile Sand Filter

OWNER S, OPERATIONAL, AND MAINTENANCE MANUAL

Application for a Sewage System Permit

Basic Septic And Plumbing Maintenance. By: All-Clear Septic & Wastewater Services

SUBSURFACE INFILTRATION SYSTEM DESCRIPTION. Alternative Names: Sump, Drywell, Infiltration Trench, Infiltration Galleries, Leach Fields

1 Exam Prep Chapter 64E -6 Questions and Answers

Commonwealth of Pennsylvania Department of Environmental Protection (DEP) Bureau of Point and Non-Point Source Management Harrisburg, PA

HOLDING TANK PLANNING & INSTALLATION GUIDELINES

Chapter WASTEWATER DISPOSAL* PART I. WASTEWATER DISPOSAL*

SEWAGE DISPOSAL SYSTEMS

GUIDELINES FOR SUBMISSION OF AN APPLICATION FOR A SEWAGE SYSTEM PERMIT

Introduction to Onsite Wastewater Treatment. Ryan Gerlich Program Specialist Texas AgriLife Extension Service

LAWS AND RULES FOR SEWAGE TREATMENT, AND DISPOSAL SYSTEMS

recycle water reuse it save up to from showers & baths for flushing toilets 30% of water use

Managing your septic system

Stormwater Attenuation Systems Sustainable Drainage Solutions for Domestic & Commercial Applications

TYPES OF SEWAGE PUMPS. Solids Handling Pumps: Grinder Pumps: Effluent Pumps:

ONSITE SEWAGE SYSTEMS*

This policy will generally explain the following in regards to the City sewerage collection systems:

Jack Werner, Ph.D, Lic#255 Phone: 405/

Producer Statement. Design: On-Site Effluent Disposal Systems (AS/NZS 1547:2000)

Statement of Existing (This is not a Permit)

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter Adopt Entire Chapter as amended (amended sections listed below)

Village of Arlington Heights. Sewer Back-up Rebate Program

Design and Installation Manual for the Infiltrator ATL System in British Columbia

Soil and Site Evaluation for OSS

Alternate Systems Guidance

Contact the Jurisdictional Engineer for materials allowed by each jurisdiction.

How to Care for Your Septic System

Read Only Copy Not For Distribution. Chapter 17. Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.2 QUANTITY OF WATER REQUIRED

Last Updated March 15, 2016

NSF International Onsite Wastewater Inspector Accreditation Program

City of Grosse Pointe Park Sanitary Sewer System Inflow and Infiltration Investigation Smoke Testing

Producer Statement. Design: On-Site Effluent Disposal Systems (AS/NZS 1547:2012)

***************************************************************************************************************

SEWER SYSTEM DESIGN GUIDELINES

6.1 Introduction to Wastewater Issues

APPENDIX K PRIVATE SEWAGE DISPOSAL SYSTEMS

TABLE 1 OAR MINIMUM SEPARATION DISTANCES

PRESENTED BY: ERIC APPELWICK MN ASSOCIATION OF TOWNSHIPS NOV 17, 2017

This unofficial translation of. Ministerial Decision No 421/1998. was downloaded from METS is not the copyright owner.

Private Sewage Permit Application

Michigan Criteria for On-Site Wastewater Treatment ~~~~~~~

STORMWATER AND EROSION CONTROL PERMIT

ONSITE WASTEWATER TREATMENT

GUIDANCE DOCUMENT FOR THE PREPARATION OF ENGINEERED SEWAGE DISPOSAL SYSTEM & SEWAGE FEASIBILITY REPORTS

Geotextile Sand Filter

SEPTIC PUMPOUT INITIAL DATA REVIEW. A presentation by the Westchester County Department of Planning

a) Biological Oxygen Demand b) Biology Oxygen Demand c) Biochemical Oxygen Demand d) Biomicrobics Oxygen Demand

Operation and Maintenance Manual

Design of Sewerage System for Jaffarpur area in Southwest New Delhi

NEW CASTLE CONSERVATION DISTRICT. through. (Name of Municipality) PLAN REVIEW APPLICATION DRAINAGE, STORMWATER MANAGEMENT, EROSION & SEDIMENT CONTROL

Commonwealth of Pennsylvania Department of Environmental Protection (DEP) Bureau of Point and Non-Point Source Management Harrisburg, PA

Aqua-Swirl Stormwater Treatment System

Commonwealth of Pennsylvania Department of Environmental Protection (DEP) Bureau of Point and Non-Point Source Management Harrisburg, PA

Chisago County Environmental Services 313 No. Main St., Room 243 Center City, MN

EVALUATION OF GRAVELLESS PIPE SYSTEMS FOR ONSITE WASTEWATER TREATMENT ACROSS MINNESOTA

On-Site Leaching Chamber Specifications & Features. Design & Installation Manual Ohio

Chapter 3: General Regulations

TEMPORARY SEDIMENT TRAP CODE

Section 8: Amended Soil Mounds. 8. Amended Soil Mounds

TYPICAL INSTALLATION INSTRUCTIONS

S.O.P. No. HMD

TOWN OF ROTTERDAM RESIDENTIAL BUILDING PERMIT APPLICATION Ext. 395 Needed to Obtain Permit:

Grease Interceptors. Design & Operation. Material & Characteristics

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

3.0 DESIGN CRITERIA FOR SANITARY SEWER FACILITIES

SECTION EXCAVATING, BACKFILLING, AND COMPACTION FOR UTILITIES

REQUEST FOR DEVIATION WATER AND WASTEWATER SYSTEM STANDARD SPECIFICATIONS

First things first.. A Brief Overview of the PTI Program. Why offer training? PTI Survey Results. Today s Main Topics:

Product Registration Renewal #2 Notice of Proprietary Distribution Product Listing

SITE SERVICES GUELPH TRANSIT OPERATIONS & MAINTENANCE SECTION WATSON ROAD FACILITY PAGE 1 OF 6 WATER RECLAMATION PROJECT JUNE 2013

Transcription:

INSPECTIONS OF EXISTING SEPTIC SYSTEMS Frequently the transfer of ownership of single family homes entails a home inspection. If the home is served by an on-site subsurface sewage disposal system (septic system) it usually is inspected as part of the total home inspection process. The State of Connecticut does not certify septic system inspectors nor are there mandatory inspection procedures that all inspectors should follow. In an attempt to clarify this situation, the Connecticut Environmental Health Association (CEHA) organized a committee of state and local health personnel; septic system installers and cleaners, who perform inspections; home inspectors; and members of the Connecticut Association of Realtors, to develop the following Connecticut Recommended Minimum Existing Septic System Inspection Report Form. The committee is hopeful that this form will be utilized throughout the industry as a standard for septic system inspections. Prospective buyers should ask their real estate agent and/or their septic system inspector whether or not this form will be used. If the form will not be utilized, you may want to inquire as to the thoroughness of the inspection. The form is basically self-explanatory, however, the committee also concluded that general information regarding various aspects of the inspection process and a glossary of terms associated with septic systems would be helpful to the general public. For that reason a supplement to the inspection form was prepared and should be supplied along with the completed form.

CONNECTICUT RECOMMENDED MINIMUM EXISTING SEPTIC SYSTEM INSPECTION REPORT DATE: (1) PROPERTY ADDRESS: TOWN:. Type of Dwelling or Use:. (2) CLIENT INFORMATION: Client s Name: Phone #:. Mailing Address:. Town : State: ZIP:. (3) INSPECTOR INFORMATION: Inspector s Name:. Company: Phone #:. Mailing Address:. Town: State: ZIP:. DISCLAIMER: THIS INSPECTION REPORT INDICATES THE PRESENT CONDITION OF THE PRIVATE ON-SITE SUBSURFACE SEWAGE DISPOSAL SYSTEM BASED ON RECOMMENDED INSPECTION PROCEDURES OUTLINED IN THIS REPORT. THE RESULTS OF THIS INSPECTION DOES NOT GUARANTEE OR WARRANTY FUTURE PERFORMANCE. THE INSPECTION REPORT EXCLUDES AND DOES NOT INTEND TO COVER COMPONENTS THAT ARE INACCESSIBLE (BY REASONABLE HAND DIGGING) OR ARE OTHERWISE NOT OBSERVABLE. (4) RESULTS AND RECOMMENDATIONS (Check applicable items): a. System functioned properly at time of inspection b. System functioning but is not sized per current standards, no upgrade required c. System operating at capacity under current usage levels d. Plumbing leaks or wastewater routing problems in home e. Need for component replacement due to structural damage f. Further investigation of leaching system with machine digging is recommended g. Evidence of prior high liquid levels in system components h. Sewage overflow observed, repair required under permit of local health department i. Soil testing recommended to determine expansion/repair area COMMENTS AND RECOMMENDATIONS FOR ABOVE CHECKED ITEMS ON NEXT PAGE

INSPECTION REPORT PAGE 2 COMMENTS RECOMMENDATIONS NOTE: The recipient of this report should discuss any deficiencies found by this inspection with the Inspector. INSPECTION PROCEDURES (5) RECORDS AND DATA: (OBTAIN AS MUCH AS PRACTICAL PRIOR TO THE ACTUAL INSPECTION) This information may be obtained through numerous sources, some of which is provided voluntarily, such as, through the property owner. The inspector assumes no responsibility for the accuracy of information provided in this manner. Attach copies of all available records and indicate the source of such records. RECORDS (INDICATE NUMBER OF EACH) Permit Applications: Permits to Construct: New System: Date: Source:. Repair/Alter: Date: Source:. New System: Date: Source:. Repair/Alter: Date: Source:. Permits to Discharge: New System: Date: Source:. Repair/Alter: Date: Source:. NOTE: Lack of records or data on file does not necessarily indicate that the existing subsurface sewage disposal system is non-compliant with installation standards. MAINTENANCE RECORDS Last Two Septage Pumpout Dates:, Source. Copies of Pumpout Reports: Available? (Y/N) Source. LOCATION DRAWING (AS-BUILT) Is a Location Drawing Available? (Y/N) Source.

INSPECTION REPORT PAGE 3 (6) GENERAL INFORMATION Age of System: Tank: Years Leaching Fields: Years Number of People Occupying Dwelling: Currently Anticipated. If currently unoccupied, how long has it been vacant?. Number of Bedrooms:. Water Supply to Building: Well; Comm. Well; Public water supply (7) WASTEWATER ROUTING One Tank/One System. Two or more tanks/one System Separate Gray and Black Water Systems. Does more than one sewer line leave the foundation (Y/N) (indicating possible two separate systems?) Is there an in-home ejector pump? (Y/N) Water treatment system present? (Y/N) If Yes, does backwash discharge to septic system? (Y/N) If Yes, recommend alternative. Is there a garbage disposal present? (Y/N) If Yes, recommend cleaning tank more often. Is there a sump pump present? (Y/N) If Yes, where discharged? Does the washing machine discharge to septic tank? (Y/N) If No, DYE TEST may be necessary. If discharge is to a separate drywell or separate leaching system, is it functional? (Y/N) If No, corrective action would be required. Is there any indication that sewage bypasses the septic system? (Y/N) If Yes, DYE TEST may be necessary. (8) SEPTIC TANK EVALUATION NOTE: IF DYE TEST IS NECESSARY PERFORM IT PRIOR TO PUMPING TANK TYPE OF SEPTIC TANK: Cesspool Single Compartment Two Compartment Multiple Tanks CLEANOUT OF TANK ACCESSIBLE? (Y/N) At what depth below grade? * *If greater than 12 a riser to within 12 is required by Public Health Code. TANK CONSTRUCTION: Concrete Plastic Fiberglass Metal Other:. VOLUME OF TANK: Gallons TANK COMPONENTS: PRESENT TYPE CONDITION (Y/N) COMP. (GOOD,FAIR,POOR) General Tank Inlet Sewer Line Inlet Baffle Outlet Baffle Effluent Filter Compartment Wall Has there been any indication of previous higher than normal levels of septage in the tank? (Y/N) What is actual distance between liquid level in tank and tank ceiling? inches

INSPECTION REPORT PAGE 4 If septic tank was pumped, did sewage flow back into the tank from the leaching fields? (Y/N) (this may indicate either, the system is flooded or, there is blockage occurring in the distribution system) What was the amount of solid build-up in the tank at the time of inspection: Excessive Normal Light Is system served by a pump and pump chamber? (Y/N) If yes, give details:.. Pump in working order, with alarm, manhole to grade?.. (9) LEACHING SYSTEM EVALUATION TYPE OF SYSTEM: Trenches Galleries Pits Bed Other, Type? LEACHING AREA REQUIRED PER CURRENT STANDARDS (if perc. test info. is avail.): S.F. EFFECTIVE LEACHING AREA PROVIDED (if as-built drawing is available) S.F. Distance between septic tank/leaching fields and potable water wells: FEET* * INDICATE LOCATIONS AND DISTANCES ON DIAGRAM ON PAGE 5 Are there any structures or impermeable surfaces located over or near the leaching area? (Y/N) Describe: Were one or more of the following signs of system malfunction present? SEPTIC ODORS PONDING OR SEWAGE BREAKOUTS LUSH GREEN GRASS OVER PARTS OF SYSTEM ILLEGAL DISCHARGE Does surface water, roof drains, or sump pump runoff drain onto the leaching area (Y/N) Were distribution boxes exposed? (Y/N) What was found? Was the leaching system probed? (Y/N) What were results? Were there any leaching galleries or pits opened to observe present or past effluent levels? (Y/N) What was found?

INSPECTION REPORT PAGE 5 Was a more in-depth investigation of leaching system conducted? (Y/N) What were results? Is there an expansion/repair area available? Likely Not Likely Unknown Were there any conditions observed which could limit a repair? (wetlands, ledge outcrops, streams, etc.) _ (10) DIAGRAM OF S. TANK AND LEACHING SYSTEM LOCATION (ties from permanent structures): INSPECTOR S NAME (printed or typed) INSPECTOR S SIGNATURE PROFESSION: LIC.NO. DATE: This form has been developed by the Connecticut Environmental Health Association with assistance from the State Department of Public Health, Local Sanitarians, Licensed Installers, CT Sewage Disposal Association, CT Association of Realtors and the Home Inspection Industry SSDSINSPECTIONFORM5.DOC

SUPPLEMENT EXISTING SEPTIC SYSTEM INSPECTION REPORT May 1, 2001 I. PURPOSE Frequently prospective buyers of a single family home have many questions regarding the septic system serving the dwelling: What does the existing septic system consist of? Is it working properly? How long will it last? If it fails, how much will a replacement system cost? The attached Connecticut Recommended Minimum Existing Septic System Inspection Form, if utilized by a qualified inspector (see below), could answer many of the above questions. In order for a buyer who is not familiar with the operation and proper maintenance of a septic system to understand the terminology made in the inspection report, the following fact sheet has been prepared. Those interested in a more in-depth presentation on the subject can obtain the book, The Septic System Owner s Manual by Lloyd Kahn, Blair Allen and Julie Jones, published by Shelter Publications, copyright 2000. II. WHO IS QUALIFIED TO PERFORM INSPECTION? An inspector must have a thorough understanding of how a septic system is installed and functions. Although there is not a State certification program in Connecticut regarding septic system inspectors, the following are recommendations as to who may be qualified: - Licensed Subsurface Sewage Disposal System Installers - Professional Engineers (Sanitary/Civil Engineer Discipline) - Registered Sanitarians or Sanitarians who have been certified by State Dept. of Public Health to inspect subsurface sewage disposal systems. - Inspectors who have obtained an accreditation through training and certification from one of many sources (National Association of Waste Transporters (NAWT); National Small Flows Clearinghouse; National Sanitation Foundation (NSF); any of a number of state sponsored inspection certification programs). A key element for any of the above individuals is experience. How long have they been associated with septic system matters? Have they installed, designed or inspected many systems? 1

III. OVERVIEW OF SUBSURFACE SEWAGE DISPOSAL SYSTEM The purpose of a home's subsurface sewage disposal system (septic system) is to dispose of the wastewater generated by the occupants in such a manner that the soils on the property can disperse it without causing an adverse effect on groundwater and in turn on public health and the environment. To accomplish this, domestic sewage is directed to a system consisting of the following elements: (1) A building sewer, which connects the home's plumbing to the septic tank. (2) A septic tank, which allows for the settling of solids and provides the initial treatment of the sewage. This is where waste material is broken down by bacterial action. A properly functioning septic tank will reduce pollutant levels and produce an effluent of fairly uniform quality. (3) A distribution system, which directs the flow of effluent from the septic tank to the drainage system in a manner that assures full utilization of the system. Most systems are "gravity" systems, meaning the effluent flows through piping and distribution boxes without the assistance of any mechanical device, such as a pump or siphon. (4) A drainage (leaching) system, which disperses the sewage effluent into the surrounding natural soils. There are many types of drainage systems. The specific type utilized on a particular property is usually dependent on the soil conditions that exist on the site. Most residential installations utilize stone-filled leaching trenches, but galleries, pits and beds have historically been used. 2

For a leaching system to function properly it must: 1. Provide enough application area. The application area is the amount of surface area provided by the particular drainage system (sides and bottom area of leaching units) where sewage effluent is applied to soil. The amount of application area needed for a given house depends on the characteristics of the soils on the property and the daily flows (in gallons) generated from the house. The anticipated flow from a house is usually predicated on the number of bedrooms in the dwelling. 2. Be surrounded by natural soil conditions that will be able to dissipate and disperse the septic tank effluent discharge without becoming over saturated. 3. Provide enough capacity to store effluent during periods of unusually heavy use or when rainfall or subsurface flooding reduces the ability of the system to disperse the liquid. Note: Curtain drains/groundwater interceptor drains are sometimes installed upgrade of the drainage system to minimize high groundwater conditions. It is important to realize that, once a system has been installed, the homeowner can control only one of the above factors. The homeowner can control how much water is actually being discharged to the system. Since each system has a set maximum capacity, it behooves the homeowner not to exceed that amount. It should be a goal of the inspection to determine the estimated water usage the existing septic system can handle before it would likely become overloaded and fail. NOTE: Many homes in Connecticut are served by private wells. These homes rarely have water meters installed on the water service line coming into the home. Because of that fact those property owners are at a disadvantage when judging their water usage levels since they have no way to monitor usage. It is recommended that a water meter be installed whenever there is a concern that water usage levels from the home may exceed the capacity of the existing septic system. If a system starts to experience difficulties, what are some of the common symptoms? 1. Plumbing fixtures may exhibit difficulty in releasing their contents (slow draining, bubbling, backups, etc.). This condition may be system related but it could also indicate just a clog in the interior piping or sewer line. The homeowner should have the interior piping checked before proceeding with an investigation of the sewage disposal system. However, on newer systems or retrofits, the above symptoms could indicate that the septic tank outlet filter is becoming clogged. In that case, tank maintenance is required in order to clean the filter and, more than likely, pump the tank. 2. Large volume discharges (such as, washing machines, dishwashers and bathtubs) cause either a backup, as noted above, or an overflow of sewage above the septic tank or leaching field. This condition is usually at its worst during and/or directly following a heavy rain event. 3

3. Foul septic odors in storm drainage piping, catch basins, footing drain piping or curtain drain discharges may indicate that sewage from your or an adjacent property is entering these groundwater systems. 4. System is operating at capacity: As stated above, all leaching systems are sized to release a certain quantity of sewage each day. If the system is maintained and operated properly (the septic tank is cleaned periodically and the water usage is within limits), theoretically, the system should last indefinitely. However, if the leaching system s interface area becomes clogged or more sewage is discharge into the system then it was designed for, the system could be operating at capacity. This means that when a system is opened sewage would be observed up to and above certain system elements (outlet pipes of distribution boxes and or the septic tank). The conclusion which should be reached from such an observation is that whatever the recent daily flow from the building has been, any increase would likely cause a system failure and a need for corrective action. Gray water/black water Systems, what s the difference? A normal septic system technically is a black water system. All wastes enter a septic tank followed by a leaching system. When toilet wastes are separated from kitchen or laundry wastes the nontoilet waste discharge is defined as gray water. Separation was a standard practice of septic system installations prior to 1970. However, studies have found that gray water systems are detrimental to the environment, especially when the discharge is directed to a leaching system, bypassing a septic tank. It is for that reason that whenever an existing gray water system fails, connection must be made to the building s black water system or, a septic tank must be installed prior to a new leaching structure. IV. OLD VERSUS NEW SEPTIC SYSTEMS AND THE INSPECTION PROCESS As stated in the first section, prospective buyers of a single family home want to know what the existing septic system consists of and whether the existing system will satisfy their needs. To answer those issues the inspector must use some point of reference in order to evaluate what was found and determine the likelihood it will perform adequately. The point of reference utilized for comparison is the present Public Health Code. This may put older homes with aging septic systems at a disadvantage but it is the only way that conclusions reached during the inspection process can be consistent from one inspector to the next or from one house to the next. The client should understand, however, that an older system, which may not meet today s standards, could be perfectly adequate for their needs and may serve them well for many years. It is hoped that the inspection process will be able to give meaningful and accurate information to the client so that they can make an informed decision relative to the existing septic system. It should also be noted that whenever an older system is found to deviate from present health code requirements, the system does not have to be upgraded or repaired unless it is in a state of failure (overflow condition or illegal discharge, etc.) causing a health hazard. 4

V. GLOSSARY OF TERMS REGARDING SYSTEM SIZING Water Usage: Is the amount of wastewater that will be discharged into the system each day. For residential dwellings it is assumed that each occupant will discharge an average of 50 gallons per day (GPD). Under normal circumstances not more than two people would occupy any bedroom, therefore, a maximum of 100 GPD average usage has been set for each bedroom for sizing the system per code. For other uses, such as, office/retail, restaurant, industrial, etc., the water usage would be determined on a case by case basis. As stated in Section III, if a home is served by a well and there is a concern over water usage, a water meter should be installed. Flow Test (or push test ): Although not usually recommended, this test can be used as a screening procedure in order to expose those systems that are near capacity (on the verge of failure) and vulnerable to moderate water usage. The test consists of discharging a quantity of water into the existing septic system to simulate a typical peak usage of water by a family. After a certain amount of water is flushed down sinks, tubs and toilets, the inspector examines the leaching area to observe any signs of an overflow condition. If an overflow is observed, the conclusion reached by the inspector is that the system is not functioning properly. It should be noted, however, that passing the test does not necessarily mean that the system is working properly. There is a concern with performing this test. Unless this test is performed in a responsible, site specific manner, it could cause harm to the existing system or lead to erroneous conclusions. For more information on this test please refer to the State Department of Public Health s Buying Guide for homes served by a septic system. Number of Bedrooms: The number of potential bedrooms in a home determines the maximum occupancy for that home. This in turn will determine the size of the leaching system based on this maximum occupancy assumption. It is not possible for anyone to foresee future utilization of a home over and above the present occupants. It is for that reason that reductions in leaching system size are not allowed even though the present owners may not be using all the potential bedrooms as bedrooms (they may be using rooms as studies, or sewing rooms, or computer rooms, etc.) or occupying each room with two people. Leaching System Size: The size of a leaching system is determined by relating the percolation rate of the soil and the anticipated daily discharge, to the amount of sewage application area provided by the system. The application area is sometimes referred to as the wetted perimeter. It is the actual surface area that sewage comes in contact with just prior to entering the surrounding soil. Each type of leaching system (see Leaching System Section) provides different amounts of wetted perimeter per linear foot of system length. In a normal system, the wetted perimeter forms a biological slime layer that slows down and actually 5

renovates the sewage prior to it entering the surrounding soils. The thickness of this layer, and the speed with which sewage passes through it, will be dependent on how much suspended solids and greases are released by the septic tank. That is why it is so important to clean the septic tank out periodically to maintain a uniform quality effluent leaving the tank. SUITABLE SOIL CONDITIONS Deep Test Holes: Deep test holes are dug within and down grade of a proposed leaching area to determine the soil characteristics, maximum groundwater levels and ledge rock conditions. Depending on what is observed, the type of system and the configuration of that system will be determined. Deep test holes must be conducted and observed by a professional engineer and/or a local health department sanitarian. Percolation Tests: In order for a septic system to function properly the soils in which it is placed must be permeable. The quicker water can pass through the soil the smaller the leaching system can be. The percolation test is an empirical means utilized to estimate a soil s general permeability. Unit of measure is in minutes per inch, representing how long it takes a column of water to drop an inch in a small diameter hole dug in the soil strata that will be utilized for sewage disposal. Suitable Soils: Soils which are permeable (percolation rates faster than 60 minutes per inch) must meet other criteria prior to being deemed suitable. There must be at least 24 of permeable naturally occurring soils over ledge rock. In shallow bedrock areas substantial amounts of select (good quality) fill material would be necessary to raise the leaching system at least four (4) feet above the ledge. Also, the soil in the leaching area must not flood from seasonal high ground- water. The code requires at least 18 of unsaturated soils be present during the wettest time of the year. Naturally Occurring Soils: The code refers to a septic system being able to adequately absorb or disperse the expected amount of sewage into the surrounding naturally occurring soils without overflow, breakout or detrimental effect. Discharging a large amount of sewage in a confined area, especially if ground conditions can not support a great deal of extra water, could overload that area and lead to a septic overflow. Fill material (brought onto the site by artificial means) can never be classified as naturally occurring soil. Likewise, bringing in fill material to cover a sewage overflow condition is not an acceptable repair, since it does not correct the inherent problem of the leaching system which is its inability to release the sewage into the ground. Minimum Leaching System Spread (MLSS): In order to prevent the overflow or breakout of sewage from occurring within or downgrade of a leaching system, the Public Health Code stipulates that the system must be spread out a minimum length across the slope. The calculation of this length is determined by use of tables referred to as Minimum Leaching System Spread Factor Tables or by a formal hydraulic analysis. The greater the depth of unsaturated naturally occurring soil, the greater the slope of the ground and the faster the percolation rate are conditions which will result in reduced system spreads. In the case of repairing an 6

existing system when there is limited available area, the amount of sewage discharge from the building (home) may be restricted. Proposed additions or remodeling (which would increase the number of bedrooms) may not be allowed under these restrictions. SEPTIC TANK Purpose of Septic Tank: The septic tank s function is to slow down discharges from the building s plumbing fixtures so that solid material can fall to the bottom of the tank and greases and scum can rise to the top. A stable biological system within the tank promotes the conversion of organic solids to soluble organic chemicals and gases. The result is a relatively uniform quality septage that will proceed to the leaching fields. There is no need to introduce any commercial additives to the tank to promote biological growth. Cesspool: Cesspools were utilized frequently more than 50 years ago to dispose of all wastes from the home. A large diameter pit would be dug approximately 6 or 7 feet below grade then be lined with large stones or concrete blocks. The cesspool would then be connected directly to the home s plumbing. A cesspool is not technically a septic tank since it does not separate out solid material, allowing such material to come in contact with the soils surrounding the pit. Since this condition could lead to contamination of groundwater in the area, the current Connecticut Public Health Code requires the installation of a septic tank whenever an existing cesspool malfunctions and requires repair. Pump-Out Frequency: It is recommended that septic tanks be cleaned every 2 to 5 years. The frequency should be based on the occupancy of the home and how quick solid material builds up in the tank. It should be noted that the use of a garbage disposal significantly increases the amount of solid material and greases entering a tank and therefore, should result in more frequent pumping. Septic tanks that have less than 1,000 gallons of capacity or are undersized for the existing usage have to be pumped more frequently. Septic Tank Depths and the Need for Risers: Whenever the top of a septic tank is located deep into the ground it becomes more difficult to gain access to that tank for maintenance (cleaning and the snaking of clogged sewer line). For that reason the Technical Standards to the Connecticut Public Health Code, effective January 1, 2000 requires that all new and existing septic tanks have at least one cleanout manhole located not more than 12 from final or existing grade. When the top of a septic tank is more than 12 from grade a riser collar shall be installed over the cleanout manhole so that access to the tank will be less than 12 from grade level. Volume of Tank: The Public Health Code requires a minimum 1,000 gallon septic tank for all new buildings. For residential buildings an additional 250 gallons of capacity shall be added for each bedroom over three (3). Therefore, a four (4) bedroom home would require a 1,250 gallon tank, a five (5) bedroom home a 1,500 gallon tank, etc. If an older house has a septic tank which falls below the present sizing requirements, it does not have to be replaced (unless physically damaged in some way), but may have to be cleaned more often. 7

Inlet and Outlet Baffles/Compartment Wall: In order to reduce the flow of septage through the tank, baffles are placed on the inlet and outlet piping to and from the tank. In most cases, the baffles consist of tee connections of 4 PVC piping. The piping is submerged into septic liquid a minimum of 8 at the inlet and 10 at the outlet. On all new tanks a compartment wall is installed in order to separate the liquid in the tank into 2/3, 1/3 volumes. The septage in the tank passes from the first compartment to the second through a mid-depth opening. Outlet Effluent Filter: As of July 1, 2000, all newly installed septic tanks shall have an effluent filter placed at the outlet in place of the outlet baffle. The purpose of the filter is to trap suspended solids that are not heavy enough or have not had enough time to sink to the bottom of the tank. This occurs frequently when a tank hasn t been pumped in a timely manner and contains a significant amount of material that reduces its effective volume. Filters must be periodically cleaned so that they do not plug and back septage back into the house. The cleaning interval should correspond to the recommended pump-out frequency. If the filter plugs at a higher frequency the options would be to change the type of filter presently being utilized (increasing the flow through surface area) or, add extra filters in series to increase the time interval between cleanings. LEACHING SYSTEMS Trenches: Are linear excavations that are a maximum 48 in width and 18 in height. Trenches are backfilled with one-inch stone surrounding a 4 perforated distribution pipe located 6 or 12 above the bottom of the trench. The distribution pipe is covered with a minimum 2 of stone. Galleries: Are hollow structures that are a minimum 48 in width and of various heights (12 up to 48 ). Originally these structures were made of concrete, but today plastic structures are available either in single or multiple unit configurations. All galleries are installed with one-inch stone on each side, within the required minimum six (6) foot wide excavation. Pits: Are hollow structures that are usually placed in deep round excavations. The structures are between five (5) feet and ten (10) feet in diameter. Pits are installed with 12 to 24 of one-inch stone surrounding the units. Pits are usually installed only when groundwater levels are very low and the soil in the area has a relatively fast percolation rate. Proprietary Leaching Systems: Are various types of leaching products that combine different materials, such as, plastic, filter fabric, and cardboard, into configurations that either eliminate the need for stone, reduce the amount of select fill needed, or provide more Effective Leaching Credit per foot than more traditional products listed above. ACCESSORY ELEMENTS Curtain Drains: In some cases groundwater levels on a site may interfere with the proper operation of a septic system. If conditions permit, as determined by soil testing, a curtain drain may be installed uphill from the septic area in order to lower 8

groundwater levels. Curtains drains are not always effective in lowering groundwater levels, therefore, before a leaching system can be installed, springtime monitoring of the area is needed in order to determine the lower water table levels. Backwash from Water Treatment System: The State of Connecticut Public Health Code Technical Standards prohibits backwash from a water treatment system from being discharged into a septic system (usually by connecting the discharge hose to the sewer line leading to the septic tank). The Department of Environmental Protection (DEP) is presently developing protocols for the proper disposal of such waste. PERMIT TO DISCHARGE Permit to Discharge: After completing the installation of any subsurface sewage disposal system (new or repair) a Permit to Discharge shall be issued by the local health department. The issuance of the Permit to Discharge shall imply that an as-built drawing has been provided indicating the location of all key elements of the system, the system has been installed in accordance with code requirements (unless specific exceptions to the code are granted in the case of repaired systems) and list any limits that have been placed on the use of the system (such as, limiting the amount of daily discharge). VI. CONCLUSIONS It is hoped that the above supplement helps explain what a septic system is and how to evaluate the information supplied on the Existing Septic System Inspection Form accompanying this supplement. If you have any additional questions associated with the form please feel free to contact the inspector, your local health department or the State Department of Public Health at (860) 509-7296. 9