Replacement Heart Valve Product Description (Stented Tissue) Models Reference

Similar documents
Replacement Heart Valve Product Description (Stented Tissue) Models Reference

12 pericardial bioprostheses. 7300TFX Carpentier-Edwards bioprosthetic valved conduit

Magnetic Resonance Imaging (MRI) Safety for Boston Scientific Products. 1. WALLSTENT Iliac Endoprosthesis with Unistep Plus Delivery System

Magnetic Resonance Safety Update 2002: Implants and Devices

High quality semi-finished products and components for the medical industry

STAINLESS STEEL SHEETS

Special Metals Co., 3200 Riverside Dr., Huntington, WV U.S.A.

SEMASPEC Test Method for Metallurgical Analysis for Gas Distribution System Components

Standard Practice for Design, Manufacture, and Material Grouping Classification of Hole-Type Image Quality Indicators (IQI) Used for Radiology 1

Molybdenum. Standard Specification for Pressure Vessel Plates, Alloy Steel, Chromium- Designation: A 387/A 387M 03

Resource Guide. Section 4: Ni-Resist

Corrosion Studies on GeoBrom HG520

Corrosion Studies on GeoBrom HG520

Corrosion Studies on GeoBrom HG520

Cast steel: Group of ASTM standards for steel castings and forgings

ATI 718 ATI 718. Technical Data Sheet. Nickel-Base Superalloy INTRODUCTION FORMS AND CONDITIONS AVAILABLE SPECIFICATIONS. (UNS Designation N07718)

AEROSPACE MATERIAL SPECIFICATION

ISO INTERNATIONAL STANDARD. Implants for surgery Metallic materials Part 1: Wrought stainless steel

Discover the variety of Metal Powders

SURFACE VEHICLE STANDARD

Mathematics and Science in Schools in Sub-Saharan Africa

The Leader in the Science of Heart Valves and Hemodynamic Monitoring

AL 29-4C AL 29-4C. Technical Data Sheet. Stainless Steel: Superferritic INTRODUCTION (UNS S44735)

Standard Specification for Carbon and Alloy Steel Bars Subject to End-Quench Hardenability Requirements 1

PSection P. Sec. P Page 1

Cast Irons, Ductile Irons & Malleable Irons

January 6, Mr. Richard Gillespie Executive Director TIGHAR 2366 Hickory Hill Road Oxford, PA Report of Findings.

ISO INTERNATIONAL STANDARD. Implants for surgery Metallic materials Part 12: Wrought cobalt-chromium-molybdenum alloy

ISO INTERNATIONAL STANDARD. Safety devices for protection against excessive pressure Part 2: Bursting disc safety devices

NONFERROUS METALS AND ALLOYS

Element, Mixture, Compound Lab

Light Bases & Light Fixtures

Stainless Steel & Stainless Steel Fasteners Chemical, Physical and Mechanical Properties

The ATI 17-4 precipitation hardening stainless steel (S17400) is covered by the following wrought product specifications.

TECHNICAL SPECIFICATION Conductive Elastomer Extruded Gaskets

Specification ALLOYED STEEL FOR QUENCHING AND TEMPERING, HIGH STRENGTH All.steel f.quen.a.temp, h.str.

LABORATORY TURNAROUND TIMES AND CHARGES

41003 STAINLESS STEEL

TECHNICAL SPECIFICATION Conductive Elastomer Molded Gaskets

SILLIKER, Inc. Southern California Laboratory 6360 Gateway Drive, Cypress, CA Tel. 209/ Fax. 714/

These elements are in carbon steels in minimal amounts, usually less than 1%.

HASTELLOY B-3 alloy Principal Features

RePneu (Lung Volume Reduction) Coil System Instructions For Use

NiSPAN-C 902 (Alloy 902), UNS N09902

Section [ ] Stormwater Catch Basin Filtration Device

MRI Safety. How can we ever forget?? July Missile Effect. Have we lost sight of our MR Safety responsibility?

MILITARY HANDBOOK METALLIC MATERIALS AND ELEMENTS FOR AEROSPACE VEHICLE STRUCTURES

SUB-Programs - Calibration range Fe Base for "PMI-MASTER Pro" Spark - mode Fe 000

Electron Beam Melted (EBM) Co-Cr-Mo Alloy for Orthopaedic Implant Applications Abstract Introduction The Electron Beam Melting Process

CONTENTS. Chapter 1 Macrostructure

316/316L STAINLESS STEEL

Innovative medical tubes

441 STAINLESS STEEL. Good High-Temperature Oxidation Resistance. Applications Potential

ISO INTERNATIONAL STANDARD. Implants for surgery Metallic materials Part 12: Wrought cobalt-chromium-molybdenum alloy

Douglas G. Brookins. Eh-pH Diagrams. for. Geochemistry. With 98 Figures and 61 Tables. Springer -Verlag Berlin Heidelberg New York London Paris Tokyo

Shaft and housing materials, coatings, and lubricants for optimal cryogenic sealing

COMMERCIAL ITEM DESCRIPTION SPECIFICATION SHEET COCK-VALVE, DRAIN, WITH HOSE BIB, 150 PSI, NON-FLAMMABLE LIQUID OR GAS, NPTF-1 THREADS

DATA SHEET ZERON 100 UNS S32760 THE GLOBAL LEADER IN SPECIALTY ALLOYS ALLOYS AND PROCESSING

ATI 45Nb Alloy. ATI 45Nb Alloy. Technical Data Sheet. Titanium Alloy

Materials Declaration Form

AEROSPACE MATERIAL SPECIFICATION

5072 CHEMISTRY (NEW PAPERS WITH SPA) TOPIC 9: METALS 5067 CHEMISTRY (NEW PAPERS WITH PRACTICAL EXAM) TOPIC 9: METALS

: Series 300 Stainless Steel Wire Brushes

Machinability Enhancement of PM Stainless Steels Using Easy-Machinable Stainless Steel Powder. Bo Hu, Roland T. Warzel III, Sydney Luk

CHROMESHIELD 22 STAINLESS STEEL

Subway Cars. Applications Potential

4 Shielded Metal Arc Welding*

Approval of subjects for measurements at ultra-high-field MRI

ATI Datalloy HP TM Alloy

Applications Potential

Machinability is the ease with which a given material may be worked with a cutting tool

Technical Data. BLUE SHEET Allegheny Ludlum Corporation Pittsburgh, PA. Stainless Steels Types 321, 347 and 348 (UNS S32100, S34700 and S34800)

ATI 825 ATI 825. Technical Data Sheet. Nickel-base Alloy INTRODUCTION PRODUCT FORMS SPECIFICATIONS & CERTIFICATES (UNS N08825)

COMPANY LOCATION APPROVED PROCESS SPECIFICATION

ATI FLAT ROLLED PRODUCTS Brackenridge, PA for technical competence in the field of

CURRENT METHODOLOGIES & CHEMISTRIES UTILIZED IN EFFECTIVE PASSIVATION PROCEDURES

Martensitic. stainless steels. Types 410, 420, 425 Mod, and 440A TECHNICAL DATA BLUE SHEET GENERAL PROPERTIES APPLICATIONS PRODUCT FORM

Prevention Strategies Design and Coatings

Nickel Based Superalloy Incoloy 800 (UNS N08800)

Precision Engineered Parts

Galvanic Corrosion Prevention Guide for Water Cooling Systems

001- Engineering Skills Principles-1. Chapter - 03 Material

Passivity Definitions and Influencing Parameters


15 Cr-Cb ULTRA FORM STAINLESS STEEL

THERMAK 17. High Temperature Strength. Superior Oxidation Resistance. Excellent Thermal Fatigue Resistance. Equiaxed Microstructure

Titanium Alloys. Fast Turnaround Processing. Low Width Thickness Ratio 3:1 unique to the industry (normal minimum is 8:1)

SAPAG. A full range of API 526 flanged safety relief valves for process applications, gas, steam and liquid. Safety Relief Valve Series 8100/8200

Chapter 2. Magnetic Resonance Safety. Andrew Simmons and Kristina Hakansson. Abstract. 1. Legislation, Guidance and Best Practice

Chapter 1.6. Polished Single-Crystal Silicon, Prime Wafers (all numbers nominal) Wafer Specification Table. Diameter 100 mm 4-inch 150 mm 6-inch

PAGE 1/6 ZAPP PRECISION WIRE INCOLOY ALLOY 27-7MO (UNS S31277)

Leadership in Soft Magnetic Alloys

High-performance age hardenable nickel alloys solve problems in sour oil & gas service

Inconel Ni-Cr-Fe Alloys Incoloy Fe-Ni-Cr Alloys Monel Ni-Cu alloys

HASTELLOY ALLOYS: SOLUTIONS TO SEVERE WET FLUE GAS DESULFURIZATION ENVIRONMENTS

BLACK STURGEON LAKES WATER QUALITY MONITORING

Automotive & Mechanical Applications Broad Base. Best Solutions.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

AQA GCSE Design and Technology 8552

Mold Design. 12. Mold Materials. Bong-Kee Lee School of Mechanical Engineering Chonnam National University

Transcription:

Dear Imaging Center: This letter is in response to your inquiry concerning the safety of performing magnetic resonance (MR) procedures in patients who have been implanted with Edwards Lifesciences LLC (formerly Baxter Healthcare Corporation, CardioVascular Group) Heart Valve Therapy Products: MR Safety: MR procedures have been performed on numerous occasions on patients with Edwards s implantable products without reported problems. The products listed below are non-ferromagnetic or weakly ferromagnetic. For the weakly ferromagnetic products, the in vivo forces are greater than those pertaining to the magnetic field interactions (i.e., the forces associated with translational attraction and torque are less than those associated with gravitational forces). Thus, these products are considered safe for patients undergoing MR procedures using MR systems operating with static magnetic fields as described below. Product Information: Replacement Heart Valve Product Description (Stented Tissue) Reference Carpentier-Edwards Bioprostheses (Aortic, Mitral) 2625, 6625 1 Carpentier-Edwards S.A.V. Bioprostheses (Aortic, Mitral) 2650, 6650 1 Carpentier-Edwards PERIMOUNT Pericardial Bioprostheses (Aortic, Mitral) 2900, 6900 1 Carpentier-Edwards PERIMOUNT Plus Pericardial Bioprostheses (Mitral) 6900P, 6900PTFX 1 Carpentier-Edwards PERIMOUNT Magna Pericardial Bioprosthesis (Mitral) 7000TFX 1 Carpentier-Edwards Bioprosthetic Valved Conduit 4300 1 Testing of these devices in a magnetic field of 1.5, 3.0, and 8.0 Tesla has shown that these devices are safe and compatible during MRI (magnetic resonance imaging) procedures. Valve stent frames are composed of Elgiloy, a corrosion-resistant cobalt-chromium spring alloy. Elgiloy is commonly used in implantable devices because of its rust-resistant and non-magnetic properties. The nominal composition (wt. percent) of Elgiloy is as follows: Cobalt Chromium Nickel Molybdenum Manganese Carbon Beryllium Iron 40% 20% 15% 7% 2% < 0.10% < 0.10% 5.8% Replacement Heart Valve Product Description (Stented Tissue) Reference Carpentier-Edwards PERIMOUNT Magna Pericardial Bioprostheses (Aortic) 3000, 3000TFX 1 The device has been shown not to have magnetic interactions at up to 8 T. It is also safe with respect to RF heating at 1.2 w/kg for up to 15 minutes. Artifacts have been determined at 1.5 T. Valve stent frames are composed of Elgiloy, a corrosion-resistant cobalt-chromium spring alloy. Elgiloy is commonly used in implantable devices because of its rust-resistant and non-magnetic properties. The nominal composition (wt. percent) of Elgiloy is as follows: Cobalt Chromium Nickel Molybdenum Manganese Carbon Beryllium Iron 40% 20% 15% 7% 2% < 0.10% < 0.10% 5.8% AR01123 Page 1 of 6

Replacement Heart Valve Product Description (Stented Tissue) Reference Cribier Aortic Bioprosthesis PHV1-23 N/A (Exclusively for Clinical Investigations/ Investigational Device/ To Be Used by Qualified Investigators only) Cribier-Edwards Aortic Bioprosthesis (Exclusively for Clinical Investigations/ Investigational Device/ To Be Used by Qualified Investigators only) 9000, 9000PHV, 9000MIS N/A Non-clinical testing has demonstrated that the Cribier-Edwards aortic bioprosthesis is MR Conditional. It can be scanned safely under the following conditions: Static magnetic field of 3 Tesla or less. Spatial gradient field of 720 Gauss/cm or less. Maximum whole-body-averaged specific absorption rate (SAR) of 3.0 W/kg for 15 minutes of scanning. In non-clinical testing, the device produced a maximum temperature increase of 0.5 C at a maximum whole body averaged specific absorption rate (SAR) of 3.0 W/kg for 15 minutes of MRI. MR image quality may be compromised if the area of interest is in the exact same area or relatively close to the position of the device. The valve s stent frame is composed of stainless steel material. The nominal composition (wt. percent) of the stainless steel material used is as follows: Chromium Nickel Molybdenum Maganese Silicon Copper Carbon Phosphorus Sulfur Iron 17.3% 14.4% 2.53% 1.74% 0.54% 0.093% 0.026% 0.017% 0.001% Bal Replacement Heart Valve Product Description Reference Carpentier-Edwards BioPhysio Valve (Exclusively for Clinical Investigations/ Investigational Device/ To Be Used by Qualified Investigators only) 3100TFX N/A The device has been shown not to have magnetic interactions at up to 3 T and relatively insignificant magnetic interactions associated with exposure to 8.0 T MRI systems. It is also safe with respect to RF heating at 1.5 w/kg for up to 20 minutes. Artifacts have been determined at 1.5 T. The frame of the valve is composed of Nitinol, an alloy with high flexibility characteristics. The nominal composition (wt.percent) of the nitinol is as follows: Nickel Carbon Oxygen Iron Titanium 55-57% 0.05% Max 0.05% Max 0.05% Max 42.85% Min Replacement Heart Valve Product Description (Stentless Tissue) Edwards Prima Aortic Stentless Bioprosthesis Edwards Prima Plus Aortic Stentless Bioprosthesis These valves are made of porcine aortic valves and there are no metal components. Model 2500 2500P AR01123 Page 2 of 6

Replacement Heart Valve Product Description Reference (Bileaflet Mechanical) Edwards MIRA Mechanical Valve (Aortic, Mitral) 3600, 3600f, 3600u, 9600 1 Testing of these devices in a magnetic field of 1.5, 3.0, and 8.0 Tesla has shown that these devices are safe and compatible during MRI (magnetic resonance imaging) procedures. Valve housing is composed of ASTM B348 Grade 5 Ti-6Al-4V titanium alloy coated with turbostatic carbon. Leaflets are composed of graphite substrate coated with pyrolytic carbon. The nominal composition for Ti-6Al-4V titanium alloy is as follows: Nitrogen Carbon Hydrogen Iron Oxygen Aluminum Vanadium Titanium < 0.03% < 0.10% < 0.0125% < 0.40% < 0.20% 5.5 to 6.75% 3.5 to 4.5% Balance (~90%) Replacement Heart Valve Product Description Reference (Bileaflet Mechanical) Edwards-Duromedics Bileaflet Prostheses 3160, 3160 R, 9120, 9120R 2 (Aortic, Mitral) Edwards TEKNA Bileaflet Valve (Aortic, Mitral) 3200, 9200 2 Testing of these devices in a static magnetic field up to 1.5 Tesla show that they are safe during MR procedures performed at 1.5 Tesla or less. Valve housings are composed of solid pyrolytic carbon and the leaflets are graphite substrate coated with pyrolytic carbon. The retainer rings in the sewing ring are commercially pure titanium grade II. The stiffener rings are Stellite 25. The nominal composition (wt. percent) for Stellite 25 is as follows: Cobalt Chromium Tungsten Nickel Iron Manganese Carbon 50% 20% 15% 10% < 3% 1.5% 0.1% The nominal composition (wt. percent) for commercially pure titanium grade II is as follows: Nitrogen Carbon Hydrogen Iron Oxygen Titanium < 0.03% < 0.10% < 0.012% < 0.30% < 0.25% 99% Replacement Heart Valve Product Description (Ball and Cage Mechanical) Starr-Edwards Prostheses (Aortic, Mitral) 1000, 1200, 2300, 2310, 2400, 6000, 6120, 6300, 6310, 6320, 6400 Reference Testing of these devices in a static magnetic field up to 1.5 Tesla show that they are safe during MR procedures performed at 1.5 Tesla or less though they are weakly ferromagnetic. Pre-1000, Pre-6000, 2, 4, 5 Starr-Edwards Prostheses (Aortic, Mitral) 1260, 2320, 6520 (plastic disk) Testing of these devices in a static magnetic field up to 2.35 Tesla show that they are safe during MR procedures performed at 2.35 Tesla or less though they are weakly ferromagnetic. Valve cages are comprised of Stellite 21. Additionally, the hollow balls of the metallic ball valves ( 2300, 2310, 2320, 2400, 6300, 6310, 6320 and 6400) are also composed of Stellite 21. The nominal composition (wt. percent) of Stellite 21 is as follows: Cobalt Carbon Manganese Silicon Chromium Nickel Molybdenum Iron 61.5% <0.35% < 1.0 1.0% 28.5% <1.0% 6% 0.75% 2, 3 AR01123 Page 3 of 6

Valve Repair Product Description Reference Carpentier-Edwards Classic Annuloplasty Rings (Mitral, 4400, 4500 1 Tricuspid) Carpentier-Edwards Classic Annuloplasty Rings with Duraflo 4425, 4525 1 Treatment (Mitral, Tricuspid) 3 Edwards MC Tricuspid Annuloplasty Ring 4900 1 Testing of these devices in a magnetic field of 1.5, 3.0, and 8.0 Tesla has shown that these devices are safe and compatible during MRI (magnetic resonance imaging) procedures. Rings have titanium alloy cores. The nominal composition (wt. Percent) of the titanium alloy is as follows: Nitrogen Carbon Hydrogen Iron Oxygen Aluminum Vanadium Titanium < 0.05% < 0.08% < 0.012% < 0.25% < 0.13% 6% 4% 89% Exceptions: Carpentier-Edwards Annuloplasty Rings, 4400 and 4500, marketed from 1980 to 1983, were made of stainless steel. Therefore we are unable to advise on the safety of MR procedures for patients with these particular annuloplasty rings. These older rings were labeled with lot numbers (not serial numbers) that had the following format: 1C005 (i.e., where the first character was numeric, the second character was a letter from A to L and the last three or four characters were numeric.) Currently marketed rings are made of titanium alloy and are issued serial numbers with four to six numeric digits (e.g., 123456). Valve Repair Product Description Reference Carpentier-McCarthy-Adams IMR ETlogix Annuloplasty Ring (Mitral) 4100 1 GeoForm Annuloplasty Ring 4200 1 The device has been shown not to have magnetic interactions at up to 8 tesla. It is also safe with respect to RF heating at 1.2 W/kg for up to 15 minutes. Artifacts have been determined at 1.5 tesla. Rings have titanium alloy cores. The nominal composition (wt. percent) of the titanium alloy is as follows: Nitrogen Carbon Hydrogen Iron Oxygen Aluminum Vanadium Titanium < 0.05% < 0.08% < 0.012% < 0.25% < 0.13% 6% 4% 89% Valve Repair Product Description Reference Carpentier-Edwards Physio Annuloplasty Ring 4450 1 (Mitral) Carpentier-Edwards Physio Annuloplasty Ring with Duraflo Treatment (Mitral) 4475 1 Testing of these devices in a magnetic field of 1.5, 3.0, and 8.0 Tesla has shown that these devices are safe and compatible during MRI (magnetic resonance imaging) procedures. Rings have Elgiloy bands separated by polyester film strips covered by silicone rubber and a woven polyester covering. The nominal composition (wt. percent) of Elgiloy is as follows: Cobalt Chromium Nickel Molybdenum Manganese Carbon Beryllium Iron 40% 20% 15% 7% 2% < 0.10% < 0.10% 5.8% AR01123 Page 4 of 6

Valve Repair Product Description Cosgrove-Edwards Annuloplasty Band (Mitral, Tricuspid) 4600 Cosgrove-Edwards Annuloplasty Band with Duraflo Treatment (Mitral, Tricuspid) 4625 These bands are composed of a silicone rubber strip impregnated with barium sulfate covered with a woven polyester cloth and there are no metal components. Equine Pericardial Patch Model Equine Pericardial Patch XAG These patches are constructed from equine pericardial tissue and there are no metal components. Contact us in the USA at 800-424-3278 or outside the USA at 949-250-2500 if you have any questions. Sincerely, Technical Support AR01123 Page 5 of 6

Pertinent References: 1. Shellock FG, Prosthetic heart valves and annuloplasty rings: assessment of magnetic field interactions, heating, and artifacts at 1.5-Tesla. Journal of Cardiovascular Magnetic Resonance 2001; 3(4):317-324. 2. Shellock, F.G., Pocket Guide to MR Procedures and Metallic Objects: Update 2000, Lippincott Williams & Wilkins, Philadelphia, PA, 2000. 3. Shellock, F.G., Crues, J.V. High-field-strength MR imaging and metallic biomedical implants: an ex-vivo evaluation of deflection forces. Am J Roentgenol 1988; 151:389-392. 4. Soulen, R.L., et al, Magnetic Resonance Imaging of Prosthetic Heart Valves, Radiology 1985; 154:705-707. 5. Hassler M., Le Bas J.F., Wolf J.E., et al. Effects of magnetic fields used in MRI on 15 prosthetic heart valves. J Radiol 1986; 67:661-666. Additional references that discuss MR procedures and heart valve prostheses: 6. Ahmed, S., Shellock, F.G. Magnetic resonance imaging safety: implications for cardiovascular patients. Journal of Cardiovascular Magnetic Resonance 2001; 3(3):171-182. 7. Randall, P.A., et al, Magnetic Resonance Imaging of Prosthetic Cardiac Valves In Vitro and In Vivo, Am J Cardiology 1988; 62:973-976. 8. Shellock, F.G., MR Imaging of Metallic Implants and Materials: A Compilation of the Literature, Am J Roentgenol 1988; 151:811-814. 9. Shellock, F.G. Magnetic Resonance Procedures: Health Effects and Safety, CRC Press, Boca Raton, FL, 2001. 10. http://www.mrisafety.com - This website was developed and is maintained by Frank G. Shellock, Ph.D. Edwards, the stylized E logo, Edwards Prima, Edwards-Duromedics, Cribier-Edwards, BioPhysio, IMR ETlogix, Carpentier-McCarthy-Adams IMR ETlogix, GeoForm, Magna and TEKNA are trademarks of Edwards Lifesciences Corporation. Edwards Lifesciences, Carpentier-Edwards, PERIMOUNT, Carpentier-Edwards Classic, Carpentier- Edwards Physio, Carpentier-Edwards S.A.V., S.A.V., Cosgrove-Edwards, Edwards MC 3, Starr-Edwards, PERIMOUNT Magna, PERIMOUNT Plus, Edwards Prima Plus, Edwards MIRA and Duraflo are trademarks of Edwards Lifesciences Corporation and are registered in the U.S. Patent and Trademark Office. Elgiloy is a trademark of Elgiloy Limited Partnership. Stellite is a trademark of Cabot Corporation. Edwards Lifesciences LLC One Edwards Way Irvine, CA USA 92614 Phone: 949.250.2500 Fax: 949.250.2525 www.edwards.com AR01123 Page 6 of 6