MICROBIO BIOAEROSOL SAMPLING

Similar documents
MicroBio MB1 IQ/OQ/PQ

UNDER SECRETARY FOR HEALTH S INFORMATION LETTER MICROBIOLOGICAL ASSESSMENT OF PHARMACEUTICAL CLEANROOMS

TWIN LASER PARTICLE COUNTER

Orthophenylphenol in healthcare environments: a trial related to a new administration method and a review of the literature*

Using the PPM2 Portable Trace Moisture Transmitter

Compact flue gas analyser: testo 300 M-I

Real-Time Microbial Detection... The Future of Mold, Bacteria and Water Damage Testing

ASSESSMENT OF BIOAEROSOL DISTRIBUTIONS IN MUNICIPAL SOLID WASTE TRANSFER STATION

Universal Bottle Sampler

Study disproves misconception about contamination of sterile IPA bottles.

What is virtual ph? An introduction to the new Petri dish ph / CO 2 sensor FREEZING INCUBATING STORING MONITORING

Ambient Air Quality Monitoring Baseline Report, Kirby Misperton A Wellsite, KM8 Production Well

PURE CULTURE TECHNIQUES

Air Quality Monitoring of Operation Theaters in Government Medical College and Hospital, Aurangabad, India

Sampling. Stationary Portable. Sampling. Sewage Treatment. Municipal Sewerage Systems. Water Protection Control

Premise Microbial Testing

PhEn-602 Notes # 4 J. Manfredi

MicroFunnel Filter Funnels

FINAL REPORT Efficacy of a Cold Plasma System

Thermoforming packaging machine R 145 with MULTIVAC Clean Design. Maximum process reliability and cleanroom suitability

Bioaerosol Sampling Cassette For the collection of viable and non-viable airborne particles

A MICROBIAL RESISTANCE EVALUATION OF INDOOR MATERIALS AIR KRETE INSULATION SAMPLE. prepared for AIR KRETE

Media Fill Test Kits USP <797> COMPLIANT. HARDY DIAGNOSTICS. Low Risk. Medium Risk. High Risk

ISO INTERNATIONAL STANDARD. Cleanrooms and associated controlled environments Biocontamination control Part 1: General principles and methods

Fluorescent Sensor Detects Microbes in Real Time

Evaluation of a Novel Non-Sterile Glove Dispensing System Uyen Nguyen

series HSD Steam sterilizer EUROSTEAM Medical device

FDA s Guidance for Industry

General European OMCL Network (GEON) QUALITY MANAGEMENT DOCUMENT

Sanitary and Environmental Engineering I (4 th Year Civil)

Sampling for Airborne Radioactivity

SA 450/60 Material Data Sheet

THE FLEXIBLE INSULATION SYSTEM TO PREVENT CONDENSATION AND ENERGY LOSSES

Clean-room technology for the pharmaceutical industry and for the industrial sector. Overall solutions. And the required products.

THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS

200 / 300 Eazy Retro Upgrade Kit

UHV Cleanliness Requirements: Cleaning/Baking and Contamination Control

Analytical Service Code

EQUIPMENT FOR AUTOCLAVING

WEATHER MONITORING. Competitive rates available for long term hire. Hire rate Per week Per month

NATURE OF MICROBES WORKBOOK

JONIX MATE NON THERMAL PLASMA TECHNOLOGY

Coliforms, Total and E. coli

Model FD 115 Drying and heating chambers Avantgarde.Line with forced convection

Filtration Standards and Applications. Arkansas Chapter of ASHRAE December 6 & 7, 2006

Microbiological tests not just for safe drinking water. PRACTICE REPORT MICROBIOLOGY Author: Dr. Elmar Grabert, HACH LANGE GmbH, Germany

AIR quality. Air quality. For healthcare environment. Contamination control, healthcare safety

Evaluation of ATP bioluminescence swabbing as a monitoring and training tool for effective hospital cleaning

MAINTENANCE OF HVAC-SYSTEMS AND COMPONENTS, DEFINITION OF CLEANLINESS!

AIR HYGIENE TEST SUITABLE FOR ALLERGIC PEOPLE

When Quality Matters. Microbial Air Samplers: Selection Criteria in Biopharma Manufacturing. Celebrating Over 50 Years In Business!

CITY S, CITY M AIR PURIFIERS. Clean air solutions

Terminal Disinfection in Hospitals with Quaternary Ammonium Compounds by Use of a Spray-Fog Technique

FOOD AND BEVERAGE PROCESSING

Sterifix RELIABLE TECHNOLOGY FOR thermal wastewater

USP <797> and Environmental Sampling

Overview of a sterility assurance program for PET drugs

Antimicrobial Surfaces to Prevent Healthcare-Associated Infection

Advanced Grit Removal Technology

SIEMEX OIL SEPARATOR MAINTAINANCE MANUAL SIEMEX OIL SEPARATOR MAINTAINANCE MANUAL. SIEMEX (M) Sdn Bhd

Elcometer 118/2. Moisture Meter. Operating Instructions

Sterilization. Euronda Spa t (+39) m euronda.com

Your Water Treatment Technology Partners for Wash Water & Industrial Water Treatment. Design Supply Integration Installation Maintenance

Model BF 260 Incubators Avantgarde.Line with forced convection

ANALYSIS OF FUNGI (MOLD) IN THE INDOOR ENVIRONMENTS BY DIRECT MICROSCOPIC EXAMINATION. (Analysis Code: FDE)

Getting Started with ICM. Integrated Cleaning and Measurement

Inoculate: Media. Physical State of Media: Liquid. The Five I s: Basic Techniques to Culture Microbes Tools of the Microbiology Laboratory

Clean air solutions CITY M AIR PURIFIER

Why Does Rust Occur? 7.1 IN GENERAL

Characteristics Mechanical strength Air leakage Filter by-pass leakage Thermal transmittance Thermal bridge factor

Bacterial Counts - Quantitative Analysis of Microbes

filtration technology pharmaceutical, Nutraceutical, & Cosmetic industries

3M Occupational Health & Environmental Safety Division 3M EVM Environmental Monitoring Series. and Gas. Concentration Measurement

TURBIDITY TB 300 IR TB 210 IR TB 250 WL. General Catalogue April 2015

Unit Treatment Processes in Water and Wastewater Engineering

WBEA Standard Operating Procedure

EQUIPMENTS & MATERIALS COMMONLY USED IN A LABORATORY

THE REAL SCIENCE OF POLYMER ACTIVATION

Indigo-Clean White Paper: #1 Bactericidal Performance Testing of Indigo-Clean Upon Bacterial Species. Healthcare

FIDAS FINE DUST MONITORING SYSTEMS. Fidas the world s only certified optical fine dust measurement system with single particle analysis for PM 2.

Passive Monitoring: A Guide to Sorbent Tube Sampling for EPA Method 325. Nicola Watson July 2015

RD6000 Kitchen Range

ASEPTIC BIOPHARMACEUTICAL MANUFACTURING: FAQs

Coating Thickness Meter Data Sheet / Instructions

Test record CFU measurement. Test ID Site/Clinic Spijkenisse

AIR QUALITY IN SWINE-FINISHING BARNS 1

Access Chambers Systems

Porcine reproductive and respiratory syndrome virus (PRRSv): Update on Noveko s Air Filtration System. Francis Pouliot, Eng., M.B.A.

Committed to excellence

Tech Talk The Importance of Side Stream Filtration in Water and Energy Conservation By Kenn Latzer, Process Efficiency Products, Inc

Ecomotive. by Jets.

Multi-function VAC measuring instrument

Water for Instrument Processing

Semiconductor Manufacturing Facility Design

onlinecomponents.com Prototyping : The Process

TRYPTIC SOY AGAR (TSA) WITH LECITHIN AND TWEEN 80

BACTERIAL CONTAMINATION SCREENING KIT

1. Define the science of microbiology and describe some of the general methods used in the study of microorganisms

3M Microbiology. Food safety. maximized. Safety. Processing

Title: Standard Operating Procedure for the Collection of VOCs in Ambient Air Using Summa Canisters and Xontech Sampler

Transcription:

MICROBIO BIOAEROSOL SAMPLING

MICROBIO BIOAEROSOL SAMPLERS Bioaerosols are airborne particles, solid or liquid. They can be large molecules or volatile compounds. They contain living organisms. They will vary in size from a fraction of a micron to around 100 microns. As with inert "dust" particles, all bioaerosols are governed by the laws of gravity and will be affected by air movements being transported by turbulence and diffusion. Sources of Bioaerosols Outdoor areas: Wind action on soil, agitation of open water and raindrop impaction are major sources of bioaerosols. Farming of land and wastewater / sewage treatment are also significant outdoor sources. houses will generate bioaerosols. products can generate higher levels of bioaerosols. Other farming activities, cattle, swine animal Food processing plants, particularly of dairy With today s emphasis on renewables, power station biomass storage and industrial scale composting facilities are sources of bioaerosols. Indoor areas: Many indoor areas are associated with bioaerosol problems. In all food processing plants, hygiene requires that levels of airborne micro-organisms are kept as low as possible. Hospitals and healthcare facilities are not only sources of a variety of organisms, but require that patients are not exposed to any of them. The presence of undesirable bioaerosols is often associated with sick building syndrome, being one of a number of factors which contribute to building related illness. Monitoring of Bioaerosols Although the use of simple settle plates can be used for collection of bacteria and fungal spores, it can never give a quantitative determination. This passive technique will also fail to enumerate very small particles such as bacteria, which will remain suspended. The simplest quantitative method of monitoring is to use impact samplers such as the MicroBio MB1 or MB2 units. These are single stage impactors, which collect bacteria and fungal spores from air flowing at 100 litres / minute through a series of air inlets, onto an agar filled 55 mm contact plate or 90 mm Petri dish, up to a volume of 10,000 litres. The MicroBio samplers are lightweight, battery powered self contained units and do not require an external vacuum pump. T h e agar media used should be chosen to suit the organisms which are being monitored. For a wide range of bacteria use tryptic soy agar (TSA), casein soy peptone agar (CPSA) and nutrient agar (NA). There are other selective agars for more specific micro-organisms. For fungi (yeasts and moulds) use is made of malt extract agar (MEA) or rose bengal agar (RBA). After sampling with the MicroBio samplers, the agar plates are incubated for specified times and temperatures (typically 1 to 2 days at 25 to 37 deg C) and the colonies which develop are counted. A correction is applied to the count to allow for the possibility that two organisms going through one sampling hole will result in only one colony growth being observed (positive hole correction). This is determined from tables or using the downloadable spreadsheets from www.cantiumscientific.com. From the corrected count and the sampling volume used, the number of colony forming units per cubic metre (CFU/m3) can be determined.

MICROBIO MB1 The MicroBio MB1 Bioaerosol Sampler is the most economical air sampler of its kind. It has been fully validated under the UK DTI VAM programme. Capable of using both 90 mm Petri dishes or 55 mm contact plates and a wide variety of media makes the MicroBio a very low cost instrument to use. The MicroBio MB1 is an invaluable device for validating cleanrooms to ISO 14698 requirements. Features Flow rate 100 litres / minute, factory calibrated 220 hole sampling head d50 = 1.7μm 400 hole sampling head d50 = 1.35μm Sampling volume 10 to 2,000 litres Lightweight (650 g) and portable Battery powered - rechargeable or alkaline NiMh (4 x AA) cells and charger supplied Low battery indication Low noise Sample up to 60,000 litres Uses 90 mm Petri or 55 mm contact plates Supplied with the MB1 Bioaerosol Sampler Petri dish and contact plate spring sets Option of 220 hole x 1 mm stainless steel or 400 x 0.7 mm anodised aluminium sampling head Printed operating manual Padded carry bag Multi-voltage Ansmann charger with UK, Euro, USA, Australia and 12V in-car plugs and pre-charged cells so the MB1 is ready to use out of the box Certificate of Calibration

MICROBIO MB2 The MicroBio MB2 Bioaerosol Sampler has a host of features making it ideal for use in research, clean rooms, pharmaceutical validation and throughout hospitals. Fully validated under the UK DTI VAM programme as a Reference Sampler. Capable of using both 90 mm Petri dishes or 55 mm contact plates and a wide variety of media makes the MicroBio a very low cost instrument to use. The MicroBio MB2 is an invaluable device for validating cleanrooms to ISO 14698 requirements. Features Flow rate 100 litres / minute, factory calibrated d50 = 1.7μm for 220 hole head d50 = 1.35μm for 400 hole head Sampling volume 25 to 10,000 litres 6 User programmable pre-set volumes Programmable delay to start sampling up to 3 hours Tripod mounting facility Lightweight (750 g) and portable Battery powered - rechargeable or alkaline NiMh (4 x AA) cells and charger supplied Low noise Sample over 60,000 litres per charge Uses 90 mm Petri or 55 mm contact plates Supplied with the MB2 Bioaerosol Sampler Petri dish and contact plate spring sets Option of 220 hole x 1 mm stainless steel or 400 x 0.7 mm anodised aluminium sampling head Printed operating manual Padded carry bag Optional mini tripod Multi-voltage Ansmann charger with UK, Euro, USA, Australia and 12V in-car plugs and pre-charged cells so the MB2 is ready to use out of the box Certificate of Calibration

MICROBIO MB2-RSH With identical features and performance to the MicroBio MB2, the MicroBio MB2-RSH is ideal for use in sealed compartments, research, clean rooms, pharmaceutical validation and throughout hospitals. The remote sampling head may be placed inside sealed chambers and connecting cables up to 10 metres in length are available. Capable of using both 90 mm Petri dishes or 55 mm contact plates, readily available at low cost with a variety of media makes the MicroBio a very low cost instrument to use. The MicroBio MB2 RSH is an invaluable device for validating clean rooms to ISO 14698 requirements.

MICROBIO VALIDATION KIT To keep your MicroBio Air Sampler at the peak of high performance and to satisfy industry regulators and standards, regular validation is required. The MicroBio Validation Kit enables you to achieve this. The MicroBio Validation Kit allows users to calibrate their own instruments and allows validation prior to each use for IQ / OQ / PQ compliance. Supplied in a padded carry case, the kit does not require any power source and is manufactured in such a way that the calibration is fixed for life. This is achieved by high precision engineering and using variable area flow meter tubes from the world s leading manufacturer.

The ultimate portable high intensity UV search light UV Blacklight torches are widely used by hospitals, surgeries and cleaning companies, forensic investigators and police to reveal contamination not visible under normal lighting. This shows on apparently clean surfaces any areas missed during cleaning, helping to achieve and maintain high standards of cleanliness for infection control in hospitals in the fight against MRSA, C.difficile and other hospital acquired infections (HAI). Easy revelation of fluorescent effects in normal lighting conditions Re-chargeable battery operation Interchangeable battery pack Compact, lightweight and durable High intensity discharge UV bulb Long throw narrow beam UV light output Hot re-strike after 5 seconds Full UV light output after 15 seconds Re-chargeable battery operation UV-35W Blacklight Torch UV Blacklight how it works This process relies on fluorescence which can be induced in certain organic and inorganic substances by stimulation with UV blacklight. Fluorescence is a photoluminescence effect where light of a visible colour is emitted from some substances during stimulation under UV light. Additional methods would be necessary in combination with UV fluorescent inspection, such as ATP bioluminescence and microbiological testing to determine specific spoilage or pathogenic organisms. UV Blacklight Applications UV fluorescent inspection is widely used by forensic scientists to reveal evidence such as blood, urine, semen and saliva. Applications include cleanliness validation of: General and deep cleaning Floors, furniture, worktops, etc Multiple use equipment Blood pressure devices, bedding, commodes, toys, keyboards, pens, clipboards, telephones, taps, curtains, chairs and more Sterile services Surgical instruments Models available: UV-35W - high powered forensic quality inspection torch UV-3W - compact and rugged pocket torch for environmental health and nursing inspections UV-3W Blacklight Torch

Distributed by: For more information, please contact your local distributor or our Head Office Cantium Scientific Limited Clarendon Gardens, Dartford, Kent DA2 6EY, United Kingdom +44 1322 252 000 info@cantiumscientific.com Visit our website to find your local distributor www.cantiumscientific.com Designed and Manufactured in the UK