DryVAC Vapor Recovery Systems

Similar documents
Carbon Adsorption Vapor Recovery Systems

Experience In Motion. SIHI Gas separation by using membranes

Chemistry of Petrochemical Processes

GUIDANCE DOCUMENT April 6, Guidance on Estimating Condensate and Crude Oil Loading Losses from Tank Trucks

Solvent Recovery Systems

MOLECULAR GATE TECHNOLOGY FOR (SMALLER SCALE) LNG PRETREATMENT

GAS CONDITIONING FOR GAS STORAGE INSTALLATIONS

PROCESS MOISTURE ANALYZERS Measuring moisture in gas or HC liquids in hazardous areas

AKAKUS OIL OPERATIONS- LIBYA Gas Utilization& Flare Emission Reduction Project

Magnetically Coupled Submerged Cryogenic Pumps and Expanders for Ammonia Applications

Hydrate Formation in Chevron Mabee Unit for NGL Recovery and CO 2 Purification for EOR. Abstract

Simple Dew Point Control HYSYS v8.6

Inland Technologies Inc

ARE PRODUCED WATER EMISSION FACTORS ACCURATE?

Qualitative Phase Behavior and Vapor Liquid Equilibrium Core

Item Hydrogen Gas Plant

BORSIG MEMBRANE TECHNOLOGY FOR PROCESSES AND ENVIRONMENT MEMBRANE TECHNOLOGY. A Member of KNM Group Berhad

Estimation of Boil-off-Gas BOG from Refrigerated Vessels in Liquefied Natural Gas Plant

HYSYS WORKBOOK By: Eng. Ahmed Deyab Fares.

GT-LPG Max SM. Maximizing LPG Recovery from Fuel Gas Using a Dividing Wall Column. Engineered to Innovate

TECHNICAL INFORMATION Bulletin NUMBER Thirty-Four

Thomas L. Hall AWD Technologies, Inc. Houston Dow Center BIN 4A9 400 W. Sam Houston Parkway S. Houston, Texas edited by

BIOGAS PURIFICATION AND UTILIZATION. ENVE 737 Anaerobic Biotechnology for Bio-energy Production

PHYSICAL AND CHEMICAL PROPERTIES

Filtration Applications for the Refining & Petrochemical Industries

HOW TO SELECT BEST MEG RECOVERY UNIT s CONFIGURATION?

Filtration Applications for the Refining & Petrochemical Industries

PROCESS. Process Analysers For Gas and Liquid Phase

Modular Oil & Gas Equipment Onshore & Offshore

Process Gas Monitoring In Petroleum Refineries

Technical Design by AMCEC, USA. Solvent Recovery Solutions For Profitability with Compliance

Thomas G. Braga Manager, Research and Development. SulfaTreat, a Business Unit of M I L.L.C. A Smith/Schlumberger Company

SOLVENT CAPTURE FOR RECOVERY AND RE-USE FROM SOLVENT-LADEN GAS STREAMS

SOFI FILTER Self-cleaning microfilter from 1 µm

Chlorinated Organics Closed Loop Unloading of Solvent Tank Trailers

Absorption in cartridge systems for ultimate disposal, or even off-site recovery may be an alternative to use for small businesses..

20/06/2011 Seminar on Geothermal Exploitation Santiago de Chile

DOWEX OPTIPORE Adsorbents DOWEX OPTIPORE Adsorbent Cuts Costs of Cleaning Solvent from Soil Vapor Extraction Off-Gas

ADVANCED PROCESS CONTROL QATAR GAS ONE YEAR EXPERIENCE

Pivotal LNG Natural Gas Fuel for Heavy Duty Trucks. David Jaskolski Senior Account Manager

Steam Turbine Solutions

High Efficiency Liquid-Solid Separators

PROCESSING NATURAL GAS Leontev A.A. Vladimirskiy State University named after the Stoletov brothers Vladimir, Russia

CENTRIFUGAL SEPARATORS FOR INDUSTRIAL APPLICATIONS

Downsizing a Claus Sulfur Recovery Unit

Synthetic Natural Gas (SNG), The LPG Opportunity

50 Years of PSA Technology for H2 Purification

For highest levels of purity

Peerless Europe. Separation and Filtration

Urban gasoline stations: new techniques for early leak detection from USTs and removal of low concentration pollutants from groundwater

Development of an Innovative 2.5 kw Water- Silica Gel Adsorption Chiller

Title of Innovation: CorroLogic VpCI 637 TOL. Summary Description: Nominee(s) Boris Miksic, Cortec Corporation. Category: Chemical Treatment

Energy Optimized Resource Recovery Project Presented By: Curtis Czarnecki, P.E.

Feedwater Heaters (FWH)

Problems at the Cumene Production Facility, Unit 800

Gas Processing. Speed. Simplicity. Efficiency Modular Gas Processing Plants

Gas Processing. Speed. Simplicity. Efficiency Modular Gas Processing Plants

MEMBRANE TECHNOLOGY FOR PROCESSES AND ENVIRONMENT

31 st International Oil and Gas Conference and Exhibition, Siófok 6 th October 2017

A - CONTACTOR REACTOR SHELL B - TUBE BUNDLE ASSEMBLY C - HYDRAULIC HEAD D - MOTOR E - IMPELLER F - CIRCULATION TUBE

POWER RECOVERY IN FLOATING LNG REGASIFICATION PLANTS

EBTAX: The Conversion of Ethane to Aromatics via Catalytic Conversion

Springfield, Massachusetts (413)

Technical Information Paper. (R)FCC Slurry Oil Filtration

a.k.a. David N. Shaw, P. E.

Chiller Optimiser Technical Specification

Air Pollution Technology Fact Sheet

Gas Enhanced Membrane Fuel Gas Conditioning Solutions for Compressor Stations with Ultra High BTU Gases in Oil-rich Shale Plays

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment Parker N2-04

Transmission Pipeline Opportunities. Advancing Project Development in India through Public Private Partnerships

COMBINED CYCLE OPPORTUNITIES FOR SMALL GAS TURBINES

Del-Monox Breathing Air Purifiers DM Series

Water Quality Specification for Power Supplies

Low-Grade Waste Heat Recovery for Power Production using an Absorption-Rankine Cycle

Modeling and Simulation of Air Compressor Energy Use

Sanitary Sewer Extensions, Lift Stations, and Force Mains Engineering Report Form. I. General Information. 1. Name of Facility:

The World s Most Versatile Filter System

Introduction to the Safe Design of LNG, CNG and Hydrogen Refueling Stations

Your partner for the right solution

Comparing Evaporative Technologies for the Recycling of Produced Waters

Siemens Carbon Capture Technology

DAVID BRENNAN SUSTAINABLE PROCESS ENGINEERING CONCEPTS, STRATEGIES, EVALUATION, AND IMPLEMENTATION. Pan Stanford. Publishing

Biogas upgrading, compression and utilization as an alternative to CHP

B. System Design and Performance Requirements

ADECOS II. Advanced Development of the Coal-Fired Oxyfuel Process with CO 2 Separation

Enviro Voraxial Technology

Natural Gas. and the Liquefaction Process

Atlas Copco. High-pressure oil-free air piston compressors P 37 - P 275 / 25 to 40 bar / 37 to 275 kw

State of the Art in Equipment for Polyurethane Formulation and Injection using: PENTANE, METHYLAL, METHIL FORMATE, HFOs, WATER

The answer is... yes!

MAX300-RTG PRODUCT NOTE. Real-Time Gas Analysis Process Automation and Control Product Quality Analysis. Industrial Process Mass Spectrometer

Low temperature cogeneration using waste heat from research reactor as a source for heat pump

System Overview. Valve oven. Restrictor. Valve. Sample in and out

PRISM Membrane Separators for biogas upgrading... tell me more

Optimising. the LNG process. The rapidly expanding global LNG industry continues. Projects

Autogas Series. Regenerative Turbine Coro-Flo Pumps. For LPG High Differential Pressure Applications

Oxygen Removal in Natural Gas Systems

K.S. Rawat 1, H. Khulve 2, A.K. Pratihar 3 1,3 Department of Mechanical Engineering, GBPUAT, Pantnagar , India

Advanced Process Control: Quick and Easy Energy Savings

Atlas Copco. High-pressure oil-free air piston compressors P 37 - P 160 / 25 to 40 bar / 37 to 160 kw

Transcription:

DryVAC Vapor Recovery Systems HEADQUARTERS OFFICE SYMEX Americas, LLC 5397 West 86 th Street P.O. Box 681246 Indianapolis, IN 46268 Phone: 317-872-4321 Attention: Tim Hammond, Pres. Or The Tulsa Office SYMEX Americas, LLC 6840 East 112 th Street South Bixby, OK 74008-2062 Phone 918-231-9698 Attention: Bill Ball, VP E-Mail: billball@sbcglobal.net

Dryr VRU Systems Vapour Recovery Units VAPOR RECOVERY SYSTEMS Adsorption on Activated Carbon & Regeneration by means of a DryVAC Vacuum Compressor Page 3

The SYMEX Americas DryVAC VRS process consists of three major events: 1) Adsorption on activated carbon 2) Regeneration by means of vacuum 3) Re-absorption in a liquid (gasoline) Page 4

Adsorption on Activated Carbon The pore structure of activated carbon provides a fast internal surface of up to 1800 m 2 per gram (7,231,624 ft 2 per pound). This surface is activated by steam or by phosphoric acid (H 3 PO 4 ) The internal surface has a huge affinity towards hydrocarbon molecules. The loading factor for gasoline vapors is 35 to 50 % by weight. Not all the hydrocarbons are regenerated by vacuum. A significant quantity stays on the carbon and forms the so-called heel. The effective loading factor is called working capacity of the carbon. The working capacity for gasoline vapors is 4 to 20 % by weight. Gasoline vapor consists mainly of propane, butane, pentane, hexane, heptane and some aromatics. (approximately 5, 40, 40, 10, 4 and 1 percent by volume respectively All emission regulations can be achieved: TA-Luft: 150 mg/m 3 EU Directive: 35 g/m 3 US EPA 5 mg/liter loaded The natural emission value of activated carbon regenerated by vacuum is approximatley 0.1 to 2.0 g/m 3 (0.0000075 pounds per cubic foot to 0.00015 pounds per cubic foot). Page 5

Regeneration by Vacuum The loading factor of an adsorption process depends on the partial pressure of the components and the temperature. The adsorption of the hydrocarbons takes place at atmospheric pressure and temperature. The loading factor at low vacuum is much lower, providing the energy necessary to release (desorb) hydrocarbons from the surface of the activated carbon. A vacuum compressor transfers the released vapors to an atmospheric re-absorber column where they are returned to the liquid phase. The adsorption of the hydrocarbons from carbon produces heat. The temperature in the carbon bed will rise during adsorption and fall during regeneration. Because of the relative huge mass of the carbon compared to the small mass of the adsorbed vapors to be desorbed, the actual carbon bed temperature will not change significantly during proper operation. A temperature swing of approx. 5 to 15 o C (9 F to 27 F) is normal. The most effective desorption pressure is between 30 to 130 millibars absolute (0.435 to 1.885 pounds/in 2 absolute). In the last phase of the regeneration a small amount of air is bled in over the activated carbon bed from the top. This air strips and displaces hydrocarbons from the top layer of the activated carbon to ensure the desired emission level. The hydrocarbon concentration of the hydrocarbon/air mixture leaving the activated carbon beds is 80 to 100 percent by volume. This means it is relatively easy to recover the hydrocarbon vapor in a simple absorber column, operating at atmospheric pressure and ambient temperature. Page 6

Types of Vacuum Systems Vacuum can be generated in many different ways. The most important factors for the selection of the vacuum system are safety, low energy consumption, and reliability. Safety related risks are fire and explosion since the vapors may be in the flammable range. The compressor selected should be explosion-shock proof to a minimum of 10 bars (140 psig) and the internal process temperature should be less than 140 o C (284 F). (Explosive gas Group IIA, T3) Page 7

Liquid ring vacuum pumps The first VRU manufacturers used liquid ring vacuum pumps. Due to the direct contact of the vapor with the internal liquid ring inside the pump the temperature stays relatively low (40 to 70 o C, 104 F to 158 F) The energy consumption is high (0.04 kwh/m 3 ) (0.00113 kwh/ft 3 ) due to the friction losses in the liquid ring. In most applications the liquid ring needs to be protected against frost when it is idle in the wintertime. Ethylene glycol or a 85/15 percent by weight glycol/water mixture is used as seal fluid on the liquid ring. The fluid is injected into the pump and leaves the pump together with the desorbed vapors. Gasoline and glycol do not mix and can be easily separated on basis of difference in specific gravity. The glycol is cooled in a heat exchanger during its continuous circulation. Glycol is sensitive to degradation by many factors such as emulsification of hydrocarbons by virtue of mutual solvents such as MTBE and TAME used as oxygenated, ph variance leading to severe corrosion when low, and foaming and carryover when high. The result is glycol losses and/or severe corrosion. The major disadvantages of the wet vacuum system are: a) High energy consumption b) Glycol losses c) Corrosion and abrasion d) Secondary waste problem e) Limited vacuum level Page 8

DryVAC screw vacuum compressors DryVAC Screw Vacuum Compressors have been used for several years. They have been proven so reliable and beneficial that many liquid ring vacuum pumps have been replaced with DRYVac compressors. Even though the initial replacement cost is higher, the justifications for these replacements are 1) lower operational costs, 2) no waste treatment costs, 3) much lower energy costs, 4) higher reliability, and 5) increased safety. Oil injected compressors are less suitable for the application in VRS s, since some of the desorbed products will condense inside the compressor, mix with and emulsify with the lubrication oil. The DryVAC Screw Vacuum Compressors use only half the energy of a liquid ring vacuum compressor, resulting in a much lower compressor temperature (40 C to 50 o C, 104 F to 122 F). The major advantages of the DryVAC Vacuum Vapor Recovery System are: a) Low energy consumption b) No glycol losses c) No Corrosion problems d) Low vacuum level possible (Wider field of application) e) Highly reliable f) Very simple system g) Energy consumption proportional to mass of HC recovered h) Lower gasoline circulation flow rate (smaller pumps with smaller motors using lower electrical energy) Page 9

Re absorber column The vapors recovered from the loading of tank trucks consist mainly of light end hydrocarbons (butane and pentane). The most effective recovery approach is to put them back into the product they originally came from. That product is usually gasoline. The vapors removed from the activated carbon during regeneration are highly concentrated. By bringing them in direct contact with a counter flowing stream of gasoline in a re-absorber vessel, the hydrocarbon vapors leaving the vacuum compressor are recovered and sent back to storage as recovered gasoline. The air present inside the carbon beds, and the purge air pulled in during the final phase of the regeneration, saturates with hydrocarbons inside the reabsorber. It is directed into the inlet vapor stream coming from the loading rack where it enters the on-stream adsorber vessel and is recovered. This recycle flow is returned to the inlet of the system and passes through the adsorber on line where the hydrocarbons are re-adsorbed. Page 10

Gasoline circulation system The recovered products desorbed from the activated carbon during regeneration are volatile hydrocarbons, which originate from gasoline. Since they leave the activated carbon at a high concentration, they can be easily recovered in a reabsorber via a counter flow of gasoline at ambient pressure and temperature. The Reid Vapor Pressure (RVP) of the gasoline used for the recovery process will gradually increase. It is therefore recommended to use a product with a predetermined daily exchange in the terminal, to prevent the product from going off spec. The gasoline day tank is the ideal source of the absorbent. Two independent centrifugal pumps maintain the circulation of the gasoline. The gasoline flows from the top down over a bed of contact rings inside the reabsorber column. It is collected in the bottom of the column. The inlet flow to the top of the re-absorber usually has a fixed setting by means of an adjustable hand valve. The return flow is controlled in such a way that the liquid level in the bottom of the column is constant. This is accomplished by a variable frequency drive on the motor of the return pump. To prevent overfilling of the column, two independent and automatic shut-off alarm systems are included; the PLC, and a hard-wired safety loop which interact with: Motorised ball valves in the absorbents inlet and outlet line. Safety valves in the inlet and outlet lines. Automatic start of the return compressor at high level in the reabsorber during stand-by of the VRS. Page 11

Start-Stop Control of the VRS The SYMEX Americas VRS only runs during actual truck loading. This means that a signal has to be derived from loading preparation activity at the truck rack to signal that loading is about to start or stop. On modern truck terminals this signal is usually generated by the loading automation system. Energy efficient operation The rate and the hydrocarbon concentration of the vapors coming from any loading facility vary a great deal. The capacity of carbon beds and the vacuum pump is fixed. This implies that during low activity at the terminal, the VRS is oversized and the energy consumption related to the mass of product recovered is high. To offset this deficiency, the SYMEX Americas DryVAC VRS uses a dry screw vacuum compressor driven with a motor controlled by a variable frequency controller. This means that the energy consumption of the compressor is directly proportional to its speed, which his controlled proportionally to the loading rate and hydrocarbon concentration. It seems logical that the vacuum level at the end of the regeneration cycle depends on the mass of hydrocarbons to be removed. If the load on the carbon bed is low, the required end vacuum level will sooner be achieved. The vacuum level in the carbon beds is measured by means of an electronic pressure transmitter. The speed of the vacuum compressor is thereby reduced, resulting in even lower energy consumption. This way the energy consumption is proportional to the mass of hydrocarbons to be recovered. Page 12

Safety Aspects of the DryVAC VRS The DryVAC Screw Vapor Recover Unit is considered to be the most safe and reliable system available on the market today. Due to the special design of the Vacuum Compressor the thermodynamic energy required for compressing is reduced to an absolute minimum, resulting in very low compressor temperatures. Liquid ring compressors rely on the injection of liquid to achieve the same level of safe compression temperatures. The very solid construction of the DryVAC compressor does not present any risk of breakdown of fragile blades, spark potentials, cavitation corrosion, or corrosion, plugging, or fouling of the glycol circulation system as occurs in systems with liquid ring pumps.. The DryVAC compressor can easily be speed controlled to adapt the compression capacity to the variable vapor inlet conditions. This minimises the risk of carbon bed overheats to nearly zero. The safety and reliability of the DryVAC System is recognized by the world s major Chemical and Petrochemical industries and storage companies such as: DOW Chemicals, Oiltanking, BP Oil, SHELL, TOTAL FINA ELF, REPSOL, EKO etc. Page 13

Design Basis for a VRS The following data are required for a proper design of a VRS. The Peak Throughput The peak (maximum instantaneous) throughput is required information. It is needed to calculate the pressure drop over the entire vapor collection system including the VRS. In principle the pressure available at the vapor connection of the truck should be sufficient to transport the vapors through the vapor arm, the flame arrestors, the vapor collection pipeline and the VRS. The peak throughput depends on the number of loading arms connected simultaneously at all loading spots. For a two spot terminal this can be eight arms. For a ten spot terminal this is usually not more than twenty arms. The actual number is specific to each terminal and should be agreed upon with the terminal operator. SYMEX Americas provides basic engineering and pressure drop calculations as a standard part of the supply of the VRS. Page 14

b) The throughput per cycle The cycle time of the VRS is usually equal to the truck turn around time (15 minutes). The amount of vapor generated by the loading of trucks per cycle is equal to the sum of the truck capacities loaded simultaneously. If the average truck capacity is 35 m 3 (9,245 gallons) and the number of loading spots is four, the maximum vapor throughput per cycle is 4x 35 = 140 m 3 (36,984 gallons or 4,944 cubic feet). This value is one of the parameters to determine the size of activated carbon beds. Page 15

c) The four-hour throughput period The intensity of loading is not a constant in any terminal. Usually there is peak activity in the morning and in the afternoon. The activated carbon beds act as buffers. They store peak volumes of hydrocarbons during high loading rate periods, and give up the stored hydrocarbons during regeneration in low loading rate periods. This is why the size of the vacuum system is based on an extended period of time rather than one averaged loading cycle. If terminal activity is relatively low in the afternoon, the vacuum system creates a buffer for the next expected peak loading cycle. In order to size a VRS vacuum system the daily/weekly throughput profile is required over the total period that the terminal is open. If the loading profile of a terminal is not available, SYMEX Americas can assist in determining the actual a profile. This is done by observation, and requires the full cooperation of the client. Page 16

d) The vapor concentration The vapor concentration depends strongly on whether or not vapor balancing is actually taking place as the tank truck off-loads its product. This is mandated by the US EPA, the Clean Air Act, and Phase 2 of the EU Directive. This means the vapor circuit including the recovery of the vapors at the service station is completely closed. The concentration of the vapor above the gasoline liquid level of the in-ground storage tank at the service station will be approximately 40 percent by volume. The vapor space above diesel storage tanks contains almost no hydrocarbons. In the case of mixed loading, where gasoline and diesel are laoded simultaneously, the hydrocarbon concentration of the vapors leaving the loading rack will be less. Page 17

Outlet Recycle to VRS Inlet Recovered Vapors Gasoline from Day Tank Storage Inlet Recovered Gasoline to Storage Activated Carbon Beds Dry Dry Screw Screw Vacuum Vacuum Compressor Pump Re-Absorber Absorbants Circulation Process Flow Sheet Page 18

DryVAC VRS ILTA Land Terminal Page 18

DryVAC VRS Multi-Product marine Terminal Application Page 19

DryVAC VRS Marine Terminal Application Page 20

View of the DryVAC VRS Electronic Supervision Monitoring Hydrocarbon Emissions Page 21

View of the DryVAC VRS Supervision Application Temperature profile of the DRYVac vacuum compressor Page 22