A passive cooling system of residential and commercial buildings in summer or hot season

Similar documents
Feasibility study of a roof top Solar room heater

Solar Home Design and Thermal Mass

Experimental investigation of zero energy office under natural and forced ventilation

Case Study: Bio-Climatic Building Design for Tropical Climates

Solar Energy Technologies

A Solar Wall System Utilized in Rural Houses of Northeast China

Modelling Analysis of Thermal Performance of Internal Shading Devices for a Commercial Atrium Building in Tropical Climates

Attached Solar Greenhouse Plans for a solar heated greenhouse attached to your home

Design Considerations for Flat Plate Solar Water Heater System

CFD Simulation Studies on Integrated Approach of Solar Chimney and Earth Air Tunnel Heat Exchanger for Building Space Conditioning

The Centre for Sustainable Building (ZUB) * A Case Study

Design of Experiment for Solar Water Heater Performance Analysis

Optimisation and Cost Analysis of a Lithium Bromide Absorption Solar Cooling System

Design Strategies and Guide lines for Tropical Coast of Pakistan, Using Climate Consultant

COMFORT-PRODUCTIVITY Building costs COMFORT-PERFORMANCE. Radiant Heating and Cooling Systems for Better Comfort and Energy Efficiency INDOOR - OUTDOOR

SIMULATION MODEL IN TRNSYS OF A SOLAR HOUSE FROM BRAŞOV, ROMANIA

Assessment of the energy demand in energy-saving office buildings from the viewpoint of variations of internal heat gains

Is Passive or Active House Needed In Face of Global Warming?

SOLAR XXI: A Portuguese Office Building towards Net Zero-Energy Building

Investigation of Indonesian Traditional Houses through CFD Simulation

THERMAL MASS CHAPTER 6. Understanding thermal mass. Seasonal effects of thermal mass

ANNUAL ENERGY PERFORMANCE OF SOLAR THERMAL SYSTEMS IN BRAŞOV, ROMANIA

Thermal Comfort in Architecture

2000 Antwerp, terraced house

The Art of Thermal Mass Modeling for Energy Conservation in Buildings, Part 2

Design, construction and evaluation of a system of forced solar water heating.

Bruck an der Mur. Project summary. Energy concept: Background for the renovation reasons

The Feasibility of Wind and Solar Energy Application for Oil and Gas Offshore Platform

Field investigation on indoor thermal environment of a high-rise condominium in hot-humid climate of Bangkok, Thailand

Using passive solutions to improve thermal summer comfort in timber framed houses in South-west France

Unit 7 Overview of Solar Thermal Applications

Experimental investigation of single-phase and twophase closed thermosyphon solar water heater systems

Calculation and Fabrication of a Solar Flat Plate Collector Efficiency using Mild Steel as Absorber Plate

Solar Thermal. [Strategy]

The Potential and Challenges of Solar Boosted Heat Pumps for Domestic Hot Water Heating

Development of an Innovative 2.5 kw Water- Silica Gel Adsorption Chiller

Technical Information

Alternative Sources of Energy

CHAPTER 1: OVERVIEW OF ENERGY EFFICIENT CONSTRUCTION

MOISTURE CONDITIONS IN WALLS AND CEILINGS OF A SIMULATED OLDER HOME DURING WINTER

The Effects of Set-Points and Dead-Bands of the HVAC System on the Energy Consumption and Occupant Thermal Comfort

The optimization of the mechanical night cooling system in the office building

Energy-Efficient Passive House using thermal mass to achieve high thermal comfort

Senior Design Project for UNO. Design of the International Studies Building: An Environmental Analysis

Sapporo Net-Zero Energy Home Hokkaido, Japan. Description. Setting. Super E Canadian Member. Super E Japanese Member. Super E Case Study

ACTIVE SOLAR SYSTEMS

Solar Passive Techniques: Earth Air Tunnel

Optimization of air tightness and night ventilation for Passive houses in Italian climates under Fanger and Adaptive comfort models

Achieving Zero Carbon for Buildings in a Densely Populated City and a Subtropical Climate. Guiyi LI Construction Industry Council

Thermal insulation of buildings and cooling demand

Experimental Investigation of a New Solar Flat Plate Collector

Available online at ScienceDirect. Energy Procedia 91 (2016 )

Container Home Presentation Book 4

A COMPARISON OF PASSIVE SOLAR AND MECHANICALLY DRIVEN EARTH-TO-AIR HEAT EXCHANGERS FOR COOLING BUILDINGS

SOLAR ENGINEERING OF THERMAL PROCESSES

DESIGN STRATEGIES OF THE RESIDENTIAL BUILDING IN WARM and HUMID CLIMATIC ZONES - TURKEY

SUSTAINABLE BY PASSIVE ARCHITECTURE, USING COURTYARDS IN NON-DOMESTIC BUILDINGS IN SOUTHEAST QUEENSLAND

FLATE Hillsborough Community College - Brandon (813)

Passive Solar Design for Homes

ARPAN JOHARI. Architect. 13/08/10 AW Design. Ahmedabad

Solar Pond Potential as A New Renewable Energy in South Sulawesi

A STUDY ON DESIGN OPTIMIZATION OF A NEAR NET-ZERO ENERGY HOUSE

Bio-climatic Chart for Different Climatic Zones of Northeast India

Size: length ft., bay width ft., number of bays: Square feet of floor space: Sq. ft. of bench/floor space covered by crops:

Work Package 2: Performance of naturally ventilated buildings

Designing Air-Distribution Systems To Maximize Comfort

Design guidelines for direct ground cooling systems in different climates

Passive Houses in South West Europe

IMPACT OF COLUMNS AND BEAMS ON THE THERMAL RESISTANCE OF THE BUILDING ENVELOPE

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

White Paper. Geothermal Heating and Cooling

Green Building Guideline of Jordan

ROOF-MOUNTED ENERGY TECHNOLOGIES AND GREEN ROOFS - DISCRETIONARY HEIGHT INCREASES

Single family house in Herselt BE

Thermal Analysis of Solar Flat Plate Collector

Green Building Guideline of Jordan

OKO House by YOUMEHESHE architects

Renewable Energy Sources Solar and Wind

Solar Hot Air Collectors. Rob Taisey Assured Solar Energy

Retrofitting Adaptive Comfort Strategies into Conventionally Air Conditioned Commercial Buildings

ABSTRACT I. INTRODUCTION II. METHODS AND MATERIAL

Theory versus practice of energy and comfort in 4 low energy houses in Belgium

Great Ocean Rd Ice Creamery

Performance evaluation of an actual building airconditioning

FUNDAMENTALS OF SOLAR ENERGY

Optimising Thermal Comfort through Passive Building Design in the Maldives. Aminath RASHEED. May, Budapest. CEU etd Collection

Student Modeling Competition

UMWELT 75 YORK ST TERALBA. Australian Institute of Energy - Peter Jamieson. April 2014

Bioclimatic approaches of modern residential architecture in Cyprus,

Energy Performance of Buildings Directive and nearly-zero Energy Buildings

Example LEED-NC v2.1 Energy & Atmosphere Credit 1 Submittal

A Study on Hybrid Cooling System Involving Passive Cooling Techniques

LOW-ENERGY HOUSING ESTATE SUNDAYS

CB04. Outback House. Case Study. Creative Spaces Australia. by Casey Brown Architecture

made in paris presents a modest rebirth of the established textile factory. It integrates itself into the existing environmental

GREEK TRADITIONAL BIOCLIMATIC ARCHITECTURE

Solar Water Heaters Development In MENA Region

Observation of Liquid-filled Window without Presence of Liquid in Test Chamber

Evaluation of Energy Savings of the New Chinese Commercial Building Energy Standard

Transcription:

IOP Conference Series: Materials Science and Engineering PAPER OPEN ACCESS A passive cooling system of residential and commercial buildings in summer or hot season To cite this article: M M Rahman et al 2015 IOP Conf. Ser.: Mater. Sci. Eng. 100 012031 View the article online for updates and enhancements. Related content - Study of Natural Convection Passive Cooling System for Nuclear Reactors Habibi Abdillah, Geby Saputra, Novitrian et al. - The performance of micro heat pipes measured by integrated sensors Martine Le Berre, Guillaume Pandraud, Panagiota Morfouli et al. - Temperature changes in EBC collection devices affect observed acetone concentrations Bryan R Loyola, Abhinav Bhushan, Michael Schivo et al. This content was downloaded from IP address 148.251.232.83 on 24/04/2018 at 03:11

A passive cooling system of residential and commercial buildings in summer or hot season M M Rahman 1, M Mashud 2, C M Chu 1, M S bin Misaran 1, M Sarker 2, S Kumaresen 1 1 Materials and Mineral Research Unit, Faculty of Engineering, Universiti Malaysia Sabah (UMS) Kota Kinabalu Sabah-88400, Malaysia 2 Department of Mechanical Engineering, Khulna University of Engineering & Technology, Khulna-9203, Bangladesh Email: mizanur@ums.edu.my Abstract. The increasing number of high rise buildings may contribute to lack of natural ventilation in modern buildings. Generally, fans and air conditioning are used in the modern building for cooling and air ventilation. Most of the energy in tropical regions are consumed by heating, cooling and ventilation appliances. Therefore, solar power appliances for cooling, heating and ventilation will be a suitable option for saving energy from the household sector. A modified-structure building is designed and constructed with solar chimney to enhance ventilation rate that increases cooling performance and ensure thermal comfort. An evaporative cooler is introduced with a newly designed room to enhance the temperature reduction capacity. The room temperature is compared with a non-modified room as well as with ambient temperature. The results show that passive cooling system with evaporative cooler was able to reduce temperature by 5 C compared to the ambient temperature and about 2 C to 3 C below the reference room temperature. 1. Introduction The demands of electrical energy in developing countries depend on the economic development as well as the standard of living. Consequently, electricity is viewed as the key indicator of the economic development of the country. The generation of commercial electricity depends on the natural resources of that country generated mainly from natural gas and hydropower [1], however the reserve of the natural gas in Bangladesh is likely to deplete by the year 2020 [2]. In Bangladesh, about 40 per cent of the total energy used in the urban areas is consumed by the residential and commercial building and about 50-60 per cent of this energy is used for cooling, heating, ventilating and space conditioning in residential and commercial buildings [3]. Therefore, during hot climate or in summer when the outside temperature is high, effective passive cooling system for commercial and residential building will be a viable option. It can reduce the electricity consumption as well as extending the availability of natural resources. Bangladesh is situated between 20.30 and 26.38 Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI. Published under licence by Ltd 1

north latitude and 88.04 and 92.44 east of GMT which provides this country with abundant solar energy. The average daylight or sunlight hour throughout the year is more than 10 hours and average solar radiation varies from 4 to 6.5 kwh/m 2 -day. It indicates a good prospect for solar power ventilation system or passive cooling system for commercial and residential building in Bangladesh [1, 2]. In this study, the space cooling is defined as the rate of energy removed from the air space in order to maintain a set lower temperature than the surrounding atmospheric temperature. During summer or hot climate when the ambient temperature is high, poor ventilation and cooling system can change the environment of the residential and the commercial building in the cities and causes thermal discomfort. In addition, electricity blackout is very common in the cities of Bangladesh consequently worsening the situation [1-4]. At present all modern commercial and residential buildings are furnished with electrical appliances mainly used for cooling and ventilation, resulting in excessive energy consumption during summer. Therefore, an efficient passive cooling system coupled with a solar chimney system can minimize this energy used for the commercial and residential buildings in urban areas of Bangladesh. There are some well-established methods available for space heating by using solar energy which is direct radiation, trombe wall, transparent insulation etc. [5]. On the other hand very limited number of studies is available on space cooling by using solar energy. This is due to the skepticism on the use of night ventilation, shading, evaporative cooling etc. The earliest methods of space cooling during dry season was discussed by Bahadori in 1978 [6] and the summary of the state-of-the-art of passive cooling systems was provided by Givoni in 1991 [7]. Study also shows that in India larger parts of the central and northern regions including New Delhi experience mixed climates such as hot humid, hot dry and cold climate systems. Attempt to implement passive cooling in the city buildings in New Delhi was made in 1990 s but limited literature is found related to this study [8]. Ventilation by using natural draft system is one of the passive cooling techniques initially used for space cooling [9, 10]. Introduction of modern science and technology has significant changes in the controlling of indoor environment of commercial and residential buildings. Passive cooling system is also closely related to thermal comfort of occupants of the building. Although some of the passive cooling techniques do not help to remove the cooling load significantly it does extend the tolerance of humans to achieve thermal comfort in a given space. Thermal comfort for the building can also be achieved by controlling the climate of the building, changing the site design, introducing thermal insulation, changing the behavior of the occupant, preventing the heat gains from internal sources. A hybrid system, by a combination of natural convection cooling and cooling system with evaporative cooler can prevent heating of the building as well as enhance the cooling efficiency to improve thermal comfort conditions in buildings [11-15]. In this paper a solar chimney-driven passive cooling system capable of enhancing ventilation above normal natural draft system is discussed for providing thermal comfort conditions inside a building throughout the summer season in hot and humid climates. 2. Methodology Figure 1 shows the model of the passive solar ventilation and cooling system consisting of a solar chimney or solar air heater or simply a mechanical ventilator system. The model is developed in the laboratory of the Mechanical Engineering Department at Khulna University of Engineering and Technology (KUET) Bangladesh. In the solar passive cooling model (figure 1), solar air heater with chimney is used to enhance the suction of the hot air from the space during day time. At bottom, a water tank is used as evaporative cooler. A circular copper tube is used as inlet duct which is completely immersed in the water tank. The whole system worked as a heat exchanger. Thermal energy was transferred from the hot air to the cold water. The evaporative cooler was insulated to protect heat transfer from ambient air and was shaded to protect radiation absorption. 2

3. Design 3.1. Modification of Room for Thermal Load Reduction The physical dimension of the existing single room was approximately. The longer side of the room was aligned to the east-west direction. Thirteen centimeter wide bricks were used to build surrounding walls with a reinforced concrete slab of 10 cm thickness. A wooden door of about 60 cm 2 face area was used in the north facing wall. After completing the construction of the room, ambient and room temperatures were measured and found to differ by 5 0 C. Transparent glass Absorber Plate Solar chimney Solar collector Air flow passage Plaster (1.5 cm) RCC (13.0 cm) Air gap (2.0 cm) Inlet Evaporative cooler Room Insulation (2.0 cm) Brick wall (13.0 cm) Figure 1. Cross-sectional View of Solar Passive Model. The above mentioned passive cooling system used a natural draft solar chimney which had a solar heat collector and a transparent glass. In the solar chimney, the solar energy was absorbed by the solar collector and transferred to the adjacent air. The stack effect caused air flow through the solar chimney. Air flow rate in a normal solar chimney may reduce due to cross wind and flow reversal [16]. To overcome this problem, the chimney was installed on a base opposite to the air flow direction. Solar chimney was also placed at 45 to the horizontal axis, to receive maximum sunlight during day time. 3.2. Solar chimney In the solar passive cooling system, the solar chimney was fabricated with mild steel sheet. The dimensions of the solar chimney were. Glass wool insulation was used at the bottom and at the sides. The solar chimney was installed to face north, where the open loop system was set with a tilt of 45 from the horizontal, having an air flow passage above the absorber plate. 3.3. Evaporative cooler An insulated water tank was used as evaporative cooler. A 7.5 cm diameter copper pipe was immersed in the water and was used as the inlet of the solar passive model room. Water of the tank exposed to the ambient air evaporated and cooled. Warm fresh air passing through the copper tube transferred heat to the water and air and water became cool compared to ambient air, subsequently this cooled air would reduce the room temperature. 3

4. Performance analysis An ordinary room with the same physical dimensions as the solar passive model room and without solar chimney is selected as the reference room. The room temperature was collected from 21 st to 25 th May, 2014 and presented in the figure 2. It was found that, the solar chimney passive cooling model room was able to maintain the temperature at about 4 C to 5 C below the outside ambient temperature and at about 2 C to 3 C below the reference room temperature. Figure 2. (a) 21 st May, 2014 Figure 2. b) 22 nd May, 2014. Figure 2. (c) 23 rd May, 2014. Figure 2. (d) 24 th May, 2014. Figure 2. (e) 25 th May, 2014 Figure 2. Variation in Temperature between Passive Room, Reference Room and Ambient Atmosphere. 4

Cheikh and Bouchair in 2008 [17] also developed a passive cooling system for house by introducing a passive cooling roof and were able to lower the temperature about 6 o C to 10 o C than ambient. The passive cooling roof was fabricated with steel structure, rocks and a water bed which was costly in comparison with brick structure. Raman et al. in 2001 [8] also used solar chimney with evaporative cooling system and found that during hot dry months (April July), the experimental room temperature was 2 o C -3 o C less than the room without passive cooling system. Typical ambient temperature during these times is varied from 30 o C to 42 o C. The comfortable room temperature was about 22 o C therefore it cannot be concluded that the above described passive cooling system performances were satisfactory but that it could reduce indoor room temperature significantly. Cubic polynomial curves were obtained for the passive cooling room, reference room and ambient temperature by using least-squares regression analysis from Microsoft Excel. All curves had good fit with data points. Among all the curves, the passive cooling room temperature curve shows weak relation with data. This is because solar chimney and evaporative cooler might have enhanced ventilation and cooling rate therefore time had very little effect on passive cooling room temperature. The data also indicate that the passive cooling room temperature was significantly below the reference room temperature. 5. Discussion The main components of solar passive system are solar chimney, evaporative cooler and additional wall insulation described in this paper. The solar passive system showed good performance for providing thermal comfort during hot climate. It also had the ability to reduce the air conditioning load of buildings during summer and able to reduce the extensive use of electrical cooling appliances. Solar passive cooling system performance data were taken for an empty room. It must be borne in mind that human activity, appliances, metabolism etc. may alter the performance of solar passive system. In addition the performance of solar chimney may decrease due to back flow, cross wind etc. that may change also the performance of solar passive system. 6. Conclusion A passive solar system for cooling, de-humidification and ventilation during hot environment has been tested on an experimental room with modified structure. The investigation has confirmed the effectiveness of passive cooling system in comparison to a reference room. The results show that cooling inside buildings can be enhanced by changing the design of the building to include a solar chimney for natural draft ventilation. By installing solar chimney, evaporative cooler and wall insulation, it is estimated to increase the cost by about 10 per cent of the cost of a conventional room. Therefore, the described passive cooling system with effective modified chimney seems to have very good potential value in terms of economy and also technological point of view. References [1] Anam K, Bustam H A 2011 Cyber Journals: Multidisciplinary Journals in Science and Technology, Journal of Selected Areas in Renewable and Sustainable Energy (JRSE) September Edition [2] Rahman M S, Saha S K, Khan M R H, Habiba U, Hosse S M 2013 GJRE-F: Electrical and Electronic Engineering 13 [3] Roodman D M, Lenssen N K, Peterson J A 1995 A building revolution: how ecology and health concerns are transforming construction Worldwatch Institute Washington, DC) [4] Cheikh H B, Bouchair A 2004 Renewable Energy 29 1877-86 [5] Passive Solar Design Handbook Van Nostrand Reinhold, New York.) [6] Bahadori M N 1978 Sci Am;(United States) 238 5

[7] Givoni B 1991 Energy and Buildings 17 177-99 [8] Raman P, Mande S, Kishore V 2001 Solar Energy 70 319-29 [9] Fischer S K, Creswick F. Energy-use impact of chlorofluorocarbon alternatives. Oak Ridge National Lab., TN (USA), 1989. [10] Van der Maas J, Roulet C 1991 ASHRAE Technical Data Bulletin 7 32-40 [11] H. A M, M. M, M. A M, R. R H M. Passive Cooling System of a Building: A New Approach. International Conference and Exhibition on Sustainable Energy and Advanced Materials; October 3-4, 2011; Solo, Indonesia2011. p. 88-94. [12] Handbook-Fundamentals A 2009 Inc, NE Atlanta, GA 30329 [13] Santamouris M, Asimakopoulos D 1996 Passive cooling of buildings Earthscan) [14] Khedari J, Boonsri B, Hirunlabh J 2000 Energy and buildings 32 89-93 [15] Lal S, Kaushik S, Bhargava P 2013 International Journal of Development and Sustainability 2 [16] Chu C C-M, Chu R K-H, Rahman M 2012 Advanced Computational Methods and Experiments in Heat Transfer XII, WIT Transactions on Engineering Sciences 75 73-82 [17] Cheikh H B, Bouchair A 2008 The Open Fuels & Energy Science Journal 1 6