OPACI-COAT 300 SPANDREL GLASS. DATA SHEET / Quebec. Version 2.1

Similar documents
CERAMIC FRIT SPANDREL GLASS. DATA SHEET / Quebec. Version 2.1

Repair Maintenance Hangar Phase II August 2010

Insulated Glass Units

Spandrel Glass Types and Recommendations

ICD High Performance Coatings. Contractor Manual

SECTION DECORATIVE GLASS GLAZING. A. Decorative specialty glass glazing for interior applications, including:

GENERAL REVELATION FOR SHIPPING CONTAINERS

Section Glass Wall Cladding

S P A N D R E L SPECIFICATION GUIDE

PRODUCT SPECIFICATION SERIES 9000 WINDOW WALL THERMALLY BROKEN ALUMINUM CASEMENT / AWNING / FIXED WINDOW

SECTION GLASS AND GLAZING PART 1 - GENERAL

A typical structural glazing system is composed of a number of essential components:

Sealant and Edge Deletion Guidelines

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

Structural Performance Tests of VHB Structural Glazing Tapes

hansen glass processors HansenGlass

Deloitte Tower: First LEED Platinum-Certified Office Building in Montreal

YES SSG TU Vent Window System

GlassWin System. Structural glazing with PVC-U profiles

Film Installation Tools

HomeMaker3 Windows and Doors

A. Section includes glazing for the following products and applications and of the following types:

SPECIFICATION SECTION : FIRE RATED GLASS PYRAN Platinum min. Fire Rated Ceramic Glass

Kingspan Day-Lite Klick

WESTECK WINDOWS and DOORS

Basic Weatherization Building Shell Sealing Caulking, Weatherstripping, Gaskets and Glazing Repair. Building Shell Sealing.

SECTION DECORATIVE METAL AND GLASS RAILING

SECTION GYPSUM WALLBOARD SYSTEMS. A. Gypsum board at new wall partitions or where indicated on drawings. B. ASTM C442 - Gypsum Backing Board

TIE Aluminum Guide Spec: Thermally Improved Windows & Doors

B. Related Sections: 1. Division 07 Section "Joint Sealants" for sealing of expansion, contraction, control, and isolation joints in tile surfaces.

CSI GUIDE Countertops

GigaCrete Specification PlasterMax. PlasterMax : Fire Rated Plaster for Direct Application over Cement Masonry Units (CMU) Interior Walls

OptiLiner Banded Liner System, Thermal, Metal Building

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

SECTION ALUMINUM WINDOWS

YCW 250 I-Beam Curtain Wall System Installation Manual

Tech Solutions WEATHERMATE Straight Flashing. Commercial Installation Guide

Residue on Glass. Glass Technical Document TD-107

A. Source Limitations: Obtain each type of building insulation through one source.

Note: Any verbiage written in red needs to be specified. All other options should be deleted

ENERGY EFFICIENT GLASS LESS ENERGY, MORE SAVINGS, BETTER FUTURE

Magnetic Dry Erase Chalk Image Projection Paintable Custom

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

This Installation Guide uses the following symbols to indicate important information. Always observe the instructions indicated by these symbols.

T700 SERIES(AW50)-Impact (Formerly 8050 series) SINGLE HUNG 3 1/4 FRAME DEPTH (SIDE LOAD)

HYDRAULIC GATE SEALS. Industrial Rubber Supply (1995) Ltd.

Challenges of Bent Insulating Glass

Building Systems. 1-Part Silicone Weatherseal for Structural Glazing. Product Description. Product Data Sheet Edition_1, 2009 Sikasil WS-305 CN

Dynamic Bonding Systems B.V. A division of Dutch Bonding Group B.V.

General Applications Before applying, mix the pre-measured catalyst* into Liquid Roof by following label directions.

Product Data Sheet Edition 25/01/2006. Sikasil WS-305. Product Description. Uses. Characteristics / Advantages

Glass Breakage Failure Mode and Stress Estimation

LUX Specifications. Section S - Preformed Steel Siding

GU A R D I A N GL A S S

EXPERIENCE INOVO IN ACTION

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

Extreme Sealing Tape

VELUX America Inc. SPECIFICATION FOR MODEL FS NO LEAK FIXED SKYLIGHT SECTION UNIT SKYLIGHTS

Tidy tiles Walls, floors, stairs and tiles on tiles Building materials of brand-name quality for your home Nur im

SECTION [ ] [08450] GLASS FACADES

U-Factor, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report

15YR INNOVATION FRAMES & GLAZING

Guide Specifications Section

SECTION MANUFACTURED ROOF EXPANSION JOINTS

System Recommendation SR0618

Standard Guidelines and Tolerances Flat/Curved Glass Products: Tempered, IGUs, Laminated (Annealed or Tempered), CurvaSmart XIR, CurvaPrint, and

PALISADE PD 40 SECTION SOLAR CONTROL FILMS. A. Optically clear Titanium Nitride ceramic sputtered polyester film for solar control.

MASTERSPEC - SHORT FORM. B. See Division 5 Section "Metal Stairs" for steel tube railings associated with metal stairs.

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

Total Window. U-Factor. Total Window U Value. Duralite can improve. Warmer window. comfortable.

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING PYRAN Platinum F min. Fire Rated Filmed Ceramic Glass

Guide Specifications Section

INSTALLATION INSTRUCTIONS

General Guide to Joint Sealants for Architects

Air and Vapor Barrier 3015

PRODUCT DESCRIPTION Titan / Tritan 6500 Series

RS32 Multi-Section Skylight System under/over seam clip double diverter

BIRD FRIENDLY ACID-ETCHED GLASS

VELCRO brand Adhesives. p re s s u re sensitive, fire re t a rd a n t, solve n t and heat ac t i v a t e d

Windows. inspired by you.

Title Page Table of Contents Instruction to Bidders Form of Proposal Equal Opportunity Statement Form of Guarantee Supplemental General Conditions

Alveo Adhesive Coating. Sekisui Alveo foams tape carriers for energy-efficient buildings

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

TREAT RISING DAMP AND REDECORATE IN UNDER 24HRS

SECTION Solar Control Film WINDOW FILM. Copyright ARCAT, Inc. - All rights reserved

Se incluyen las instrucciones en español

GLASS DESIGN GUIDELINES

Coated Glass. Stopsol Sunergy Planibel G

UltraPruf II SCS2902

SECTION THROUGH-PENETRATION FIRE STOP SYSTEMS

RS24-10 Single-Section Skylight System

Making Your Own Interior Storm Windows

Structural Glass Systems

Heat Treated Glass for Architectural Glazing

BEP Blue Barrier Installation and Application Guide

Architectural Testing ASTM E283, ASTM E330, ASTM E331 TEST REPORT. Report Number: C Rendered to: Tubelite Inc.

SWING DOOR SPECIFICATION

Hygienic Cladding Solutions. White, Pastel & Vibrant Colours. Satin & Gloss Ranges

Transcription:

SPANDREL GLASS OPACI-COAT 300 DATA SHEET / Quebec Version 2.1

Glass with MULTIVER OPACI-COAT 300 SPANDREL GLASS DEFINITION A glass panel assembled with an opaque layer in position 2 or 4 of a sealed unit. Spandrel glass is generally used to hide the building s structure between floors. Spandrel glass must be placed in front of an opaque insulated panel with a minimum air gap of 25 mm to avoid thermal bridging and improve air flow. OPACI-COAT 300 SPANDREL GLASS DEFINITION After tempering or heat strengthening the glass, an even, opaque layer of coloured silicone-based paint is applied to the glass with a rotating roller. OPACI-COAT 300 spandrel glass does not look perfectly even when exposed to light sources passing through both sides of the glass. For this reason, this product must always be placed in front of an opaque panel. STANDARDS AND CERTIFICATES Multiver meets the following requirements : CAN/CGSB 12.1 Tempered or Laminated Safety Glass ASTM C1048 Heat-Treated Flat Glass *Other standards and certificates may apply. 2/11

BENEFITS Building s esthetic quality. Gives a uniform and homogeneous look to buildings. Can be matched to the colour of the glass and sealed units of a building s windows or curtain walls. Wide array of colours to choose from, allowing for varied visual effects. Easy to install and requires minimal maintenance. Elegantly dissimulates building elements that are visually undesirable. May allow for beneficial heat gain in certain parts of a building. Jules-Dallaire Complexe - glass 3/11

Spandrel Glass Manufacturing Process MULTIVER OPACI-COAT 300 Precise glass cutting using our computer numerical control (CNC) machine. Shaping, washing and drying of the glass. The shaping of the glass allows us to refine the edges of the glass, thus limiting the risk of breakage in the tempering oven. At this stage of the manufacturing process, it is possible to make notches or holes into the glass, under certain conditions. Contact us for more detailed technical studies. The glass is then washed to remove any impurities or dirt that could still be on the glass. Tempering by increasing the temperature of the glass and then rapidly cooling it. Through this process, the glass becomes safer and stronger Application of the OPACI-COAT 300 coating using a rotating roller. As the glass moves forward on a conveyor belt, an even coating of OPACI-COAT 300 of the desired colour is applied to the glass as it passes under a rotating roller that simultaneously touches both the paint and glass. Drying of the OPACI-COAT 300 coating on the glass. Ventilators lightly dry the opaci-coat 300 coating just deposited onto the glass surface. MANUFACTURING SIZE Minimum : 16 inches (406 mm) diagonally Maximum : 86 inches X 144 inches (2184 mm X 3658 mm)* Glass thickness : Minimum 3.3 mm and maximum 19 mm *The maximum size may vary with glass less than 6 mm thick 4/11

Standard colours available MULTIVER Clear Anodised Green Harmony Blue Silver Bronze Lava Blue Harmony Black Charcoal Primary White Evergreen Taupe Greylite Forest Green Concrete Grey * OPACI-COAT 300 colours may vary depending on the type of glass selected. *The colours shown above are for reference only. *A minimum quantity is required for orders including non-standard colours. *It is recommended to use a single glass thickness for a given project to ensure that the whole projet be of the same uniform colour, unless otherwise intended. *In order to maintain the integrity of the colour of the spandrel glass, it is recommended to use low iron glass, especially for lighter colours. 5/11

SEALANT COMPATIBILITY The OPACI-COAT 300 coating may change colour if used with incompatible products. Please refer to the following list to avoid any problems. LIST OF MATERIALS AND SEALANTS APPROVED BY OUR OPACI-COAT 300 SUPPLIER Bostik...3190 Boss Products...Boss 396 CR Laurence...RTV408 Dap...230 Sealant Dow Corning...799 Clear Dow Corning...795 Dow Corning...983 (2 part) Dow Corning...983 (2 part) Dow Corning...995 Dow Corning...797 (Europe = 795) Dow Corning...793 (Asia = 795) GE Silproof...2000 GE GESIL...N 2600 NPC...Solar Seal #900 NPC...Silicone Construction Sealant Pecora Corp...864 Silicone Pecora Corp...895 Silicone PRC...4400 2-part Silicone PTI...Architectural Sealant #707 PTI...Architectural Sealant #738 PTI...Acrylic Plus Sealant #767 PTI...Butyl Sealant #757 PTI...Sealant T360-626 Rhone Poulene...Rhodosil 5C Rhone Poulene...Rhodosil 3B Tremco...Spectrum 2 Setting blocks must be silicone based and not neoprene based to avoid contamination of the OPA- CI-COAT 300 coating. LIST OF ADHESIVE TAPES AND GASKETS APPROVED BY OUR OPACI-COAT 300 SUPPLIER 3-M...Double Sided Tape... 4462-B 3-M...Double Sided Tape... 9731 3-M...Double Sided Tape... 4932 Central Plastic...Santaprene Blocks... 201-87 Clean Seal...Silicone Rubber... 8556P-SP CR Laurence...T Bond II Tape... V221212 CR Laurence...PHS Styrene Shims... Custom Extruder...Glazing Tape... 799 General Sealants...Caskats... GS #4 Gray General Sealants...Gaskets... GS # 1500 Morton Thickol...PIB... T-850 Norton...Thermalbond Tape... V2200 Norton...Glazing Tape... V-788 Tremco...Shim Tape... 440 Preshim Tremco...Glazing Tape... SST800 Tremco...Swiggle Strip... Valey Ind. Plastic...Bond Breaker... VIP #40 Valey Ind. Plastic...Bond Breaker... VIP #531 Valey Ind. Plastic...Thermal Foam DC Tape... VIP #4070 1/2... VIP #3070 3/8 6/11

INSTALLATION Make sure that the installation complies with the regulation currently in effect. OPACI-COAT 300 spandrel glass assembled as a sealed unit must be approved by a curtain wall specialist or supplier. In order to avoid undesirable colour changes, it is essential to ensure the compatibility of adhesive tapes, sealants and gaskets that are close to or in contact with OPACI-COAT 300 spandrel glass. Special consideration should be given to membranes near OPACI-COAT 300 spandrel glass as it is very much affected by this type of product. Jules-Dallaire Complexe - glass 7/11

MAINTENANCE Once the OPACI-COAT 300 spandrel glass is installed, it is recommended that all exposed surfaces be cleaned, if needed, in order to preserve the esthetic qualities of the product. Rub gently with a soft cloth, using cold or warm water and non-aggressive chemicals for all glass surfaces. Caution should be exercised when choosing cleaners. Abrasive cleaners must never be used as they can cause damage to the glass surface. Several products are specifically designed to clean glass. Metallic objects should not be used because they could scratch the glass. replaced, we strongly recommend that you look at the spacer in the sealed unit. You will then know who was the original manufacturer of the unit as well as its year of manufacture. We also require the project name and location to conduct extensive research. OPACI-COAT 300 spandrel glass must be either tempered or heat strengthened. You should therefore be able to see a laser engraved logo in one of the corners, unless it is covered. A date as well as the name of the company that tempered the glass should also be indicated. Never use any products containing solvents. Exposed glass surfaces must also be protected during the construction and renovation of a building in order to limit the risk of breakage and scratches. SEALED UNIT ASSEMBLY It is possible to use Multiver OPA- CI-COAT 300 spandrel glass on surface 4 of a sealed unit to improve the overall performance of a building s envelope. There is also a multitude of new options now available to achieve the desired look. Multiver logo - Tempered glass Slight glass or coating colour variations may cause differences from the original colour of the OPACI-COAT 300 coating, in the event of a replacement. GLAZING REPLACEMENT To help us identify the insulated unit with spandrel glass that needs to be 8/11

USEFUL INFORMATIONS We wish to remind you that the compatibility of sealants close to or in contact with products offered by Multiver must always be verified prior to installation. Failure to comply with this instruction could result in the voiding of the Multiver warranty. Consult our documents on sealant compatibility to avoid potential problems with our products. We do not recommend the application of OPACI-COAT 300 to surface 1 and/or 3 of a sealed unit. WHY HEAT STRENGTHEN OR TEMPER MUL- TIVER OPACI-COAT 300 SPANDREL GLASS? HEAT STRENGTHENED GLASS WITH OPACI-COAT 300 ON SURFACE 2 Heat strengthened glass has approximately twice the mechanical strength and thermal resistance of annealed glass. In the event of breakage, the glass will break into large pieces (lower release of energy) because the glass has been subject to less stress during the tempering process, unlike tempered glass. For this reason, when heat strengthened glass breaks it is highly probable that the glass will remain in its frame or sealant. Heat strengthened spandrel glass is therefore often used in multi-storey projects because the risk of glass falling down is considerably reduced in the case of a broken glass pane. TEMPERED GLASS WITH OPACI-COAT 300 ON SURFACE 2 Tempered glass has a better mechanical strength and thermal resistance than heat strengthened glass. It is approximately four times more impact resistant than regular non-tempered glass. If the glass breaks, it will do so with a high energy release of small fine round pieces, which reduces the risk of injury to those nearby. As a result, tempered spandrel glass is recommended for the lower floors of a project. Jules-Dallaire Complexe 9/11

USEFUL INFORMATION (CONT.) Several factors may have a considerable impact on the appearance of a selected OPACI-COAT 300 colour such as glass thickness, glass tint and reflectance, the surrounding environment, lighting, and more. It is therefore recommended to ask for a product sample (see the Sample Request form) before making the final selection of your spandrel glass. For example, standard transparent glass has a slightly green hue due to the ferrous oxides found within its composition. When seen in reflection, the light green colour will alter the OPACI-COAT 300 coating s tint. It is possible to use spandrel glass in a sealed unit in combination with tinted or reflective glass by coating surface 4 with OPACI-COAT 300. OPACI-COAT 300 can also be combined with pyrolitic or soft coated low emissivity glass in a sealed unit. Multiver OPACI-COAT 300 glass can also be combined with laminated glass in a sealed unit using laminated glass on the outer pane and OPACI-COAT 300 on surface 4. In addition to lowering the risks in the event of breakage, coloured laminates offer a wide variety of interesting looks (see our Laminated Glass document). OPACI-COAT 300 (surface 4) Sealed unit assembly options Laminated glass Low emissivity glass (surface 2) Tinted glass Reflective glass (surface 2) 10/11

This document gives a general description of the product. For further information, please contact an authorized supplier of Multiver products. The use of any of the products mentioned herein is the sole responsibility of the users. Multiver assumes no responsibility for the use of its products.