ROOF SUBSTRATE PREP MANUAL

Similar documents
DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING

TOPCOAT Restoration Specifications Fiberglass & MB Granulated Cap Sheets

FireShield System Specifications Mineral Surface Cap, Mop Granule and Torch Granule APP Cap Sheets

TOPCOAT System Specifications Corrugated Transite Panels

DURA 500 THERMOPLASTIC FLAT ROOF COATING SYSTEM BY SUPERIOR POLYMERS INC.

GE SCM3500 High Solids Silicone Roof Coating

MAKE ROOFS LAST LONGER

Guideline Specification ACRYMAX ARS-1-C Reinforced Composite Elastomeric Membrane System for Concrete Roofs Fluid-Applied Roofing

System Specifications

FLUID APPLIED ROOFING - HYPALON ROOF RESTORATION

TOPCOAT Restoration Specifications Structural Concrete

LIQUID-APPLIED ROOFING Application & Specifications Manual

Colphene BSW Training and Application Guide. Colphene BSW Waterproofing Membrane. 1. Prepare substrate

TOPCOAT Product Catalog

Acry-Tek 4200 / SPF Recoat System

A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

SECTION MANUFACTURED ROOF EXPANSION JOINTS

SECTION mil thickness COLD FLUID-APPLIED WATERPROOFING

GEOGARD LO Base Coat / GEOGARD Finish Coat

Henry #1 CHOICE OF PROFESSIONALS

SECTION ALPHAGUARD RESTORATION 20 YEAR WARRANTY SYSTEM. f. Conditions and Division 01 Specification Sections, apply to this Section.

SECTION CO-POLYMER ELASTOMERIC COOL-ROOF COATING

FLUID APPLIED WATERPROOFING

Good roofing practice has

LAKEWOOD HIGH SCHOOL RECOAT/REROOF PROJECT 100% OWNER REVIEW

2016 Capital Improvement Project REHABILITATION OF METAL ROOFING SECTION REHABILITATION OF METAL ROOFING PART 1 - GENERAL

To ensure warranty eligibility, each job must be approved by American WeatherStar before it begins.

SECTION CLAY BARREL TILE ROOFING. A. American Society for Testing and Materials (ASTM):

SCOPE OF WORK PROJECT IDENTIFICATION

SECTION COLD APPLIED RUBBER MODIFIED ASPHALT WATERPROOFING

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES

MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION

General Applications Before applying, mix the pre-measured catalyst* into Liquid Roof by following label directions.

BTM BT2K 600. Areas of Use

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

Kolorines Glass Mosaic Tiles Project Specification

AVM System 500. Aussie Membrane 500

TUFF-TAC TM BRIDGE MEMBRANE INSTALLATION GUIDE

MULE-HIDE PRODUCTS CO., INC. MULE-HIDE SELF-ADHERING TPO ROOFING SYSTEM

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: LAPOLLA INDUSTRIES, INC.

Product Data Sheet Waterproofing Membrane for Ponds and Water Features Description Uses Suitable Surfaces Additional Uses Specification

Index. Roofing. Metal Roofing Systems/Cold Process Systems. Dampproofing. Waterproofing. Sealants, Caulking, Flooring. Fabrics. Guide Specifications

Roof Repair Sealants

Application Specification:

Protective Coatings for Underground Utility Concrete Structures. By: John E. Davis Inside Sales & Marketing Specialist: Sauereisen, Inc.

8245 Remmet Ave Canoga Park, CA (888) Installation Instructions - AVM System 700 Under Tile Waterproofing and Anti-Fracture Membrane

ARDEX GUIDE SPECIFICATION ARDEX MRF Moisture-Resistant, Rapid-Drying, Skimcoat Patching Underlayment

Florock Seamless Flooring Systems

PRODUCT GUIDE SPECIFICATION

SECTION PREPARATION FOR RE-ROOFING

Section COATING RESTORATION

ITEM 458 WATERPROOFING FOR STRUCTURES

Elastomeric Protected Membrane Roofing Fluid-Applied Protected Membrane Roofing. Restoration Coating System (RCS) over Cap Sheet

Standard specification for the application of Danosa Two-Layer waterproof roofing membrane to plywood & concrete surfaces.

1-part polyurethane pourable self levelling floor joint sealant

FIRESTONE ULTRAPLY TPO SA APPLICATION GUIDE

Outline NBS Specification. Protec System to PVC Single Ply (Waterproofing Only)

SECTION G RELIEF VENTS A-0

A. Product Data: Submit manufacturer s product data, with complete general and specific installation instructions, recommendations, and limitations.

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.

Vulkem EWS with PUMA Technology (Heavy Duty) APPLICATION INSTRUCTIONS

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

Construction. S-Vap 5000E SA Self-adhesive Vapour Barrier. Product Description

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

HALIFAX HUMANE SOCIETY BOARDING AND GROOMING FACILITY SECTION STYRENE-BUTADIENE-STYRENE (SBS) MODIFIED BITUMINOUS

GAF Scheduled Maintenance Checklist

INTRODUCTION. Inspection Procedures oinitial Inspection Report. Visual Inspection Physical Sampling (Core and Slit Samples)

PEDA-GARD ALIPHATIC. Pedestrian Traffic Coatings. System Summary

PART 3 GENERAL REQUIREMENTS

Firestone Polyiso Boards

Lithia Dodge East 5500 L St. Omaha, NE

A. Section includes hydraulic-cement-based, polymer-modified, self-leveling underlayment for application below interior floor coverings.

1-part elastic joint sealant and multipurpose adhesive

CELCORE CELLULAR INSULATING CONCRETE SPECIFICATION FOR RETROFIT PLACEMENT OVER EXISTING ROOF MEMBRANES

HYDRATHANE INTERIOR WATERPROOFING MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 959 [2017] Appraisal No. 959 (2017) BRANZ Appraisals

POLYGLASS U.S.A., INC. CORPORATE HEADQUARTERS

CITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO

METHOD STATEMENT 001 CONCRETE BALCONY WATERPROOFING FOR DIRECT FIXED TILES

APPLICATION INSTRUCTIONS

SECTION Pedestrian Traffic Coatings{PRIVATE } 1.1 SUMMARY (Specification writer shall add, delete or amend, as deemed necessary)

POLYGUARD RD-6 A FAIL SAFE PIPELINE COATING SYSTEM FOR REHABILITATION OR GIRTH WELDS ON CATHODICALLY PROTECTED PIPELINES

A. ASTM C 150 Standard Specification for Portland Cement. B. ASTM C 595 Standard Specification for Blended Hydraulic Cements.

TEX COTE 600 TEXTURED COATING MASONRY PROTECTIVE COATING

Pacific Polymers Elasto-Deck BT Guide Specification

SECTION CONCRETE PAVING SLABS SET IN MORTAR

.1 Provide submittals in accordance with Section Submittal Procedures.

Roofing. Carrier Membrane SA. Self-adhesive Carrier Membrane. Product Description. Tests. Product Data. Form. Storage

SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 811 [2013] Appraisal No. 811 (2013) Amended 28 August 2017

Instruction Guide APPLICATION OF CIM TO CONCRETE

A Design Review of Waterproofing Codes

SBS Hot-Mopped & Cold Adhesive Roofing (COMGN289) Updated: 1/17

Imagine a roof that lasts forever. Restoration Solutions Engineered for the Life of your Schools

PRODUCT DATA SHEET SARNACOL 2121

Thermoplastic Single Ply & Multi-Ply Roofing Systems

RUBBERGARD EPDM SA APPLICATION GUIDE

DURO-SHIELD ROOF COATING CARE GUIDE TABLE OF CONTENTS

Construction. High performance joint sealing system. Product Description. System Data Sheet Edition _1. 1 Sikadur Combiflex SG system 1/8

SECTION JOINT SEALANTS PART 1 - GENERAL 1.01 RELATED DOCUMENTS

Transcription:

ROOF SUBSTRATE PREP MANUAL ALDOCOAT Liquid Applied Roof Restoration Systems AFTER BEFORE JULY 2016 1604 N. Main St. Kannapolis, NC 28081 (800) 474-6019 www.aldoproducts.com

ROOF SUBSTRATE PREPARATION Preparation of the roof substrate is the sole responsibility of the ALDOCOAT Approved Applicator. Carefully review and examine substrate to receive liquid applied roof restoration during a site visit. Document this visit with a report and photos. Do not proceed with system application until preparatory work has been completed or until unsatisfactory conditions have been identified, corrected and accepted by Aldo Products Company. All roofs must have positive drainage in accordance with local code requirements and NRCA best roofing practice standards. There should be no ponding water for more than 48 hours after precipitation stops. Identify and cover adjacent surfaces not to receive the reflective roof coating system. Protect rooftop units from overspray if spray application method is used. Follow the ALDOCOAT design guidelines for application instructions and acceptable weather conditions. Substrates must be clean, completely dry, and free of any debris before application of any ALDOCOAT liquid applied products. All roof coating systems and liquid applied membrane products should not be used on heavy-traffic bearing substrates. If rooftop foot traffic is expected, a coating and granule system approved by Aldo Products Company must be used. Refer to design guidelines for details. GUIDE CONTENTS Page Moisture Survey... 3 Repair... 3 Clean... 5 Adhesion Test... 5 Prime... 6 Seam Treatment... 6 Apply... 6 July 2016 Page 2 of 6

MOISTURE SURVEY It is the responsibility of the ALDOCOAT Approved Applicator to determine suitability of any substrate to receive a liquid applied roofing system. When a low slope single ply membrane (TPO, PVC, Hypalon) or a smooth/granulated modified bitumen substrate shows areas of ponding water, a third party moisture survey may be required by Aldo Products Company. A survey may involve destructive analysis to verify the suitability of the substrate can be effective. MOISTURE SURVEY POLICY AND PROCEDURE If so required by Aldo Product Company, a third party moisture survey be conducted by the roofing contractor or by an independent inspector approved by Aldo Products Company, Inc. Where the moisture survey shows areas of the roof that are wet, remove and replace all wet areas with new materials. Make typical repairs with original roof technology and follow the appropriate surface preparation steps by roofing material manufacturer. Moisture surveys may include one or all of the following: IR scans, nuclear scans, test/core cuts (destructive analysis), and portable devices used to indicate moisture. Metal substrates typically do not require a moisture scan. REPAIR Inspect and make all necessary repairs to damaged substrates. Refer to the Damaged Substrate Treatment sections below for specific substrate with which you are working. METAL SUBSTRATES AREAS OF CONCERNS Rust Areas Fasteners Open Gaps Seams TREATMENT Severely damaged or rusted seams are to be replaced. Roof panels that are corroded to the point where they have breaches in the metal allowing water penetration into the building, must be replaced with new panels. Light rust areas must be treated to prevent further deterioration on metal panels. Roof surface shall have no more than 20% rust. All fasteners must be retightened, secured, or replaced as necessary. All stripped fasteners must be replaced with new oversized fasteners. All deteriorated fasteners and washers or missing fasteners must be replaced. All fasteners must be fully encapsulated with the ALDOSEAL product listed in the project design guideline. Refer to the TDS for specific application requirements. Seal cracks, joints, penetrations and curbs with appropriate sealant materials as recommended. Repair all seams as needed. Refer to the Design Guideline for specific seam treatment guidance. July 2016 Page 3 of 6

LOW SLOPE AND SPF SYSTEMS TPO AREAS OF CONCERNS Hypalon or PVC Sprayed Polyurethane Foam EPDM Mineral & Granule Surfaced BUR or Modified Bitumen (SBS & APP) OR Smooth Surfaced BUR or Modified Bitumen (SBS & APP) Concrete Corrugated Transite Panels TREATMENT Any areas where TPO has torn, cracked, and/or buckled must be repaired using like or similar products approved by Aldo Products Company. Any wet insulation must be replaced as part of the roofing repair. Allow at least 48 hours drying time before application of liquid applied products. Any areas where Hypalon or PVC has torn, cracked, and/or buckled must be repaired using like or similar products approved by Aldo Products Company. Any wet insulation must be replaced as part of the roofing repair. Allow at least 48 hours drying time before application of roof coating products. All areas where the polyurethane spray foam (SPF) is exposed or has degraded must be removed, allowed to dry and re- foamed to bring substrate to a smooth, workable surface. Any areas where foam has become wet must be removed and re-foamed. All new SPF product for repair must be purchased from Aldo Products Company, Inc. Any areas where EPDM has torn, cracked, and/or buckled must be repaired using similar products. Any wet insulation must be replaced as part of the roofing repair. Any areas where BUR or MB has blistered, buckled, is wet and/or otherwise damaged must be removed and repaired using similar products approved by Aldo Products Company. New BUR or MB repair materials must be allowed at least 30 days to weather before applying roof coating products. All areas where BUR or MB substrate surface has significantly craze cracked (gaps 1/16" or greater in width and/or depth) must be repaired using the ALDOSEAL product in the design guideline to bring the substrate to a smooth, workable surface. Allow at least 24 hours to dry. Areas with thicker applications may require additional drying time. All large or excessive gaps (greater than 1/4") shall be repaired using high-quality concrete grout. Grout must fully cure before application of the liquid applied roofing system. Areas of ponding water to receive a fabric fully reinforced roof coating system. Refer to the Design Guideline for instructions. Asbestos transite panels are not eligible. July 2016 Page 4 of 6

CLEAN VERY IMPORTANT FOR SYSTEM SUCCESS! PROCESS General Surface Prep Pressure Washing TREATMENT Clean all surfaces to receive waterproofing. Remove all dirt, dust, loose and flaking particles, grease, oil, pollution fallout, and other contaminants that may interfere with proper adhesion. Use of a pressure washer for cleaning and surface preparation is required. Additional cleaning using a bristle broom may be necessary to achieve a thoroughly cleaned surface When encountering roof substrates that have living organisms such as algae, mold or fungus, a bleach solution shall be used to kill and remove these organisms during the roof cleaning. Substrate must be pressure-washed with water and/or approved cleaner. (TSP for metal) A minimum working pressure of 3,000 psi is to be used to remove all dirt, dust, chalking and waste products (oil, oil- based roof cements, solvents, grease, animal fats, etc.). Care should be taken not to damage the roof surface or inject water into the substrate or building during washing. Allow at least 24 hours for complete drying of roof after the cleaning process. Do not proceed until surface is completely dry, including dew. ADHESION TEST When roof coating adhesion to substrate is in question, an adhesion test is required by Aldo Products Company, Inc. It is the sole responsibility of the ALDOCOAT Approved Applicator to determine the suitability prior to the installation of a roof coating system, regardless whether priming is required or not. When adhesion tests are conducted: Approved Applicator to contact Aldo Products Technical Services Department (800-474-6019) to request adhesion test instructions and kit. Test patches shall be labeled and photographed to document adhesion results for your records. Installer can consult with Aldo Products Technical Services Department (800-474-6019) concerning all adhesion test results. July 2016 Page 5 of 6

PRIME Aldo Products Company, Inc. offers various primers. It is important to choose the appropriate primer for the specific substrate with which you are working. Before the primer is applied, make sure you have followed the sections above. Application of the primer is dependent on the substrate with which you are working. Refer to the design guideline for specific primer information. Be sure to follow the application rates and specifications before applying the primer. SEAM TREATMENT Roof seams can be a primary area where leaks occur. It is important to properly treat all seams prior to the application of the ALDOCOAT liquid applied roof restoration system. All horizontal and vertical seams must be flashed in accordance with Aldo Products Company design guidelines. Refer to the substrate specific design guideline for specific seam treatment product guidance. APPLY Be sure to follow the corresponding design guidelines for the Aldo Products Company liquid applied roofing system you are working with. Refer to the Warranty Program Guide for specific application rates and warranty guidelines. July 2016 Page 6 of 6