HCL SYNTHESIS UNITS WITH ENHANCED SAFETY FEATURES

Similar documents
Electricide HG Electrochemical Chlorine Generators

Chlor-alkali Electrolysis

The ABC s of OSG (On-Site Generation of Hypochlorite and Chlorine Gas) TACWA Business Meeting Fort Worth, Texas

50 Years of PSA Technology for H2 Purification

Operation and Maintenance of Electrochlorination Plant

Electricide CDE Electrochemical Chlorine Dioxide Generators

New Technologies for Hypo Production

Electricity and Chemistry

Minimize the Risk of Fire During Distillation Column Maintenance

Item Hydrogen Gas Plant

natcom burner solutions Advanced burner technology for stringent emissions requirements

CHLOR-ALKALI INDUSTRY

Technical Description Package Micro Auto Gasification System (MAGS )

Hypochlorite Production General Information. 740 E. Monroe Road, St. Louis, MI

Sulfuric acid dilution units

COLLECTION AND INCINERATION OF HIGH VOLUME-LOW CONCENTRATION PULP MILL NONCONDENSIBLE GASES

Your partner for the right solution

Optimize to Oxidize - CPVC Weathers the Chlor-Alkali Industry s Toughest Conditions

Permissive Sequencing and ISA The Shape of Things to Come

27.0 SAMPLING AND TESTING METHODS

KEYWORDS: Deaerator, Condensate, Oxygen Removal, Boiler Feed Water, Heater, Water Treatment

METALS AND THEIR COMPOUNDS

BALCLOR TM Ballast Water Treatment System. SunRui Corrosion and Fouling Control Company 3 December 2009, Shanghai China

PUMPS FOR CHLOR-ALKALI ELECTROLYSIS

SUBMERGED COMBUSTION HEATING AND EVAPORATION

PRISM Membrane Systems for petrochemical applications... tell me more

GENERAL COMPANY FOR CHEMICAL INDUSTRIES

PTAC PROCESS TECHNOLOGY II - SYSTEMS. Last Reviewed: Page 1 of 10

Biogas Conference Kolding, DK, 04 April 2017 BINDER. Biogas Monitoring Why and How? Jan Talkenberger, Manager International Sales, Binder GmbH

ADECOS II. Advanced Development of the Coal-Fired Oxyfuel Process with CO 2 Separation

Thermal Mass Flow Meters Help Reduce Energy Costs and Enhance Emissions Monitoring Systems

POLYFLURON -E PTFE and POLYFLURON -P PTFE. The Right Column and Vessel Lining to Meet any Need. Process Technology. Broad Base. Best Solutions.

Steam Power Station (Thermal Station)

Steam Generation Solutions

TiO 2 Chloride Process. Ti-Cons. Dr. Jendro and Partner - Jendro, Weiland and Partner Management Consultants

COAL - HAZOP SYSTEMS ANALYSIS GRINDING AND FIRING

Chlor-alkali electrolysis plants Superior membrane process

ERT 318/4 UNIT OPERATIONS SEMESTER 1 (2013/2014)

How are Industry Standards, Engineering Codes, Best Management Practices and Other Measures of Compliance Being Met by Facilities?

Strategies and Intervention tactics - FC stationary installations

COMBIMASS Thermal Gas Flow

PRISM Membrane Separators for biogas upgrading... tell me more

Hydrogen Generators Flow Capacities up to 500 cc/min

Downsizing a Claus Sulfur Recovery Unit

Results are presented in Table 1. The tube was fabricated from a Type 347 and no unusual conditions were noted.

Transportation in a Greenhouse Gas Constrained World

EMOS. Electrolyzer Maintenance Optimization and Safety. General Specifications

DAVID BRENNAN SUSTAINABLE PROCESS ENGINEERING CONCEPTS, STRATEGIES, EVALUATION, AND IMPLEMENTATION. Pan Stanford. Publishing

Training Program for Urea Engineers. Complete 10-Day Detailed Urea Training

Crude Oil and Refined Products Processing

Plant construction and waste heat systems for the chemical industry

REAL-TIME PREDICTIVE ANALYTICS AND CORROSION MONITORING WITH PREDICT -RT

Electric Furnace Off-Gas Cleaning Systems Installation at PT Inco ABSTRACT

Chemical Recovery and Purification Systems for Aluminum Processing

Nuberg Engineering Limited (Strategic Collaboration Partner)

The Use of FRP (Fiberglass-Reinforced Plastic) in Phosphate Fertilizer and Sulfuric Acid Processes

A tognum Group Brand COMBINED HEAT AND POWER FROM BIOGAS

INDUSTRIAL WASTEWATER SYSTEMS

Chlor-Alkali Electrolysis

Your local nitrogen generation partner. i-flow. Nitrogen gas generation solutions for manufacturing & processing industries.

Continuous Emissions Monitoring Systems. Engineering & Design. For PetroChem Processes

Magnetically Coupled Submerged Cryogenic Pumps and Expanders for Ammonia Applications

FREQUENTLY ASKED QUESTIONS FOR THE ADVANTAGE

TSK S 3. Flap Flowmeter for liquids. Range: m 3 /h. Accuracy: ± 2.0 of reading. : PN 40, t max: C. p max

OPTIMA SLS. Ultra Low Emissions Burner

Best Practices Adopted By Shriram Alkali & Chemicals Jhagadia To improve Energy Efficiency. Navin Jaiswal Addl General Manager DCM Shriram Ltd

SODIUM SULPHITE BASED WATER TREATMENT PROGRAM FOR CLOSED CHILLED WATER SYSTEMS

Nuclear-Power Ammonia Production

Expert witness statement of Mr Edward Joseph Bechberger Expert for Gunns Limited

Material Balances. Design Project. Production of Phthalic Anhydride from o-xylene

Preliminary Lessons Learned from the Fukushima Daiichi Accident for Advanced Nuclear Power Plant Technology Development

Making the most of cooling water

BINDER. Italian German Conference Verona, Italy, 26 September Biogas Monitoring Why and How?

ELECTRICAL, INSTRUMENTATION & CONTROL SOLUTIONS FOR OIL & GAS INDUSTRY

PROCESS SAFETY MANAGEMENT PROGRAM UNIPAR CARBOCLORO

CSI G SYSTEMS CSI GAS DELIVERY SUPPORT. Chemical Vapor Deposition (CVD)

Development of HK Electric Gas Receiving Facilities at

CLEANER PRODUCTION GUIDELINES IN CAUSTIC SODA /CHLOR-ALKALI INDUSTRIES

ENVIRONMENT-FRIENDLY HYDROGEN GAS AS FUEL IN FUEL CELL AND ITS CHALLENGES

Steam balance optimisation strategies

APPLICATIONS INTRODUCTION

Springfield, Massachusetts (413)

For Safe and Delicious Water

ABB Measurement & Analytics Monitoring cement plant stack emissions using FTIR

Visual Level Indicators VLI

Stainless Steel Pressure Vessels, Process Vessels and Tanks. Examples of manufactured products

Oxy-fuel combustion integrated with a CO 2 processing unit

China - Canada Co-operation Project in Cleaner Production. Checklist for Cleaner Production Auditing in Pulp and Paper Mills

Corrosion Resistant Products for the Chlor-Alkali Industry

SOFCOM Mid Term Review

Carbon Adsorption Vapor Recovery Systems

Purification of Oxyfuel- Derived CO 2

Preliminary Hazard Analysis and Risk Assessment for the Wood Centre Development, Southwood Resources - Huon

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

Topic 2.7 EXTRACTION OF METALS. Extraction of Iron Extraction of Aluminium Extraction of Titanium Recycling

- Tensile strength of 50,000 psi per ASTM D-638 or 345 Mpa - Notched Izod impact strength of 35 ft-lb/in per ASTM D-256 or 1868 J/M are achieved.

Two Great Technologies Together At Last. The 700 Series NanoTrace Moisture And Oxygen Analyzers

HTP. HTP070 Purifier for Dielectric Fluids. PIH HTP070b

Development status of the EAGLE Gasification Pilot Plant

CASE STUDY: SAFETY INSTRUMENTED BURNER MANAGEMENT SYSTEM (SI-BMS)

Transcription:

HCL SYNTHESIS UNITS WITH ENHANCED SAFETY FEATURES CLOROSUR NOVEMBER 2016

MERSEN: WHO ARE WE? AN INDUSTRIAL BASED COMPANY SUPPLYING EQUIPMENT & KNOW HOW TO OUR CLIENTS TWO MAIN SUBDIVISIONS- PRODUCT FOCUS AREAS ADVANCED MATERIALS ELECTRICAL POWER ANTICORROSION EQUIPMENT ELECTRICAL PROTECTION & CONTROL GRAPHITE SPECIALTIES SOLUTIONS FOR POWER MANAGEMENT POWER TRANSFER TECHNOLOGIES 2015 Group Sales of ~$850 million ~7000 employees world wide 2

MERSEN: WHERE WE ARE FRANCE USA UK GERMANY CHINA MOROCCO INDIA BRAZIL Production sites: Quick Center 3

MERSEN ANTICORROSION AND PROCESS EQUIPMENT IDEALLY SUITED FOR THE CHLOR-ALKALI INDUSTRY DESIGN AND MANUFACTURE OF PROCESS EQUIPMENT : Heat exchangers, pressure vessels, mixers, columns Engineered skid packaged systems Piping, fittings IN A WIDE RANGE OF MATERIALS Graphite, SiC Tantalum, zirconium Titanium Nickel alloys PTFE, PFA Carbon steel, stainless steel FOR CORROSIVE APPLICATIONS IN PROCESS INDUSTRIES Chemicals, Fine chemicals, pharmaceuticals Hydrometallurgy & pickling Agrochemical & Water treatment 4

MERSEN ANTICORROSION AND PROCESS EQUIPMENT PRODUCTS IDEALLY SUITED FOR THE CHLOR-ALKALI INDUSTRY Graphite equipment for transformation of HCl acid and gas (heat exchangers, synthesis units) Titanium wet Cl2 coolers & demisters Titanium piping Titanium brine heaters Titanium reactors & tanks for hypochlorite (bleach) Nickel 200 coolers & heaters for NaOH PTFE piping for wet Cl2 and HCl 5

MERSEN ANTICORROSION AND PROCESS EQUIPMENT SYTEMS OFFERED FOR THE CHLOR-ALKALI INDUSTRY HCl synthesis units brine treatment H2SO4 dilution & concentration Cl2 recovery (stripping) from brine solutions Plants for PAC (PolyAluminum Chloride) Plants for FeCl3 6

MERSEN TECHNOLOGY MERSEN IS A WORLD LEADER FOR THE SUPPLY OF HCL SYNTHESIS UNITS WITH OVER 600 UNITS INSTALLED PROVIDING A TOTAL PACKAGE SOLUTION ENGINEERING Conceptual design P&ID Basic/detail engineering Main equipment supply PROCUREMENT Instrumentation Piping and valves Automated control cabinet Main equipment supply CONSTRUCTION Main equipment supply Modular assembly includes: the installation of steel structure, equipment, piping & valves, instrumentation, cabling, junctions boxes Skid-mounted turn-key solution 7 3.2

MERSEN TECHNOLOGY Hydrogen chloride is formed by burning chlorine with a slight excess of hydrogen. Cl2 (g) + H2 (g) => 2 HCl (g) + 600 kcal/kg Hydrogen chloride gas is absorbed in demineralized water to form pure hydrochloric acid. This is a combustion process involving a very reactive mixture of gases which can, if not properly managed, cause an explosion and cause major property damage and personnel injury or fatality MERSEN safety enhancements Material selection Safe equipment design Attention to control philosophy and safe practices (HAZOP/LOPA, etc.) Process control & selection of control elements BMS- Burner Management System 8

HCL synthesis units 95% of the world s units are connected to a Chlor-Alkali plant THE MEMBRANE ELECTROLYSIS PROCESS H 2 O NaCl Precipitation and filtration Dissolving station Primary brine 310 g/l Pure brine 310 g/l Dechlorination 230 g/l Secondary brine treatment Electrolysis H 2 O Caustic soda circulation 30-32% Steam Concentration 50% NaOH Cl 2 H 2 Drying compression liquefaction sniff-gas HCl synthesis unit Cooling compression NaClO unit Liquefied Cl 2 Vent gas HCl H 2 9

-explosion triangle Biggest danger with any synthesis unit is an explosion of unburned gases The explosion triangle for H2, Cl2 and air is not very forgiving The energy requirement to set off an explosion even in the mild to strong reaction area of the triangle is very small less energy than that from a small fluorescent light bulb Sunlight and even the smallest static discharge can trigger a detonation 10

-crossing the stoichiometric boundary -1/2 both the fuel (H2) and an oxidant (Cl2 or air) must be present for combustion (or an explosion) to occur and an ignition source must be present Normal operation: all of the oxidant (Cl2) is carefully combusted in the burner chamber & furnace by operating with typically 10% excess fuel (H2); stoichiometry is 1.1H2/1.0Cl2 (ratio of 1.1) Near the burner, all of the Cl2 is converted to HCl and what remains is typically ~95% HCl gas with ~5% excess H2 and other inerts from the feed gas streams After the absorption of HCl in water, what remains in the gas stream sent to the tail tower is 80% to 90%V H2 with inerts this is a danger zone if upsets occur or if a unit is controlled poorly and oxidant (air or additional Cl2) is allowed to enter 11

- -crossing the stoichiometric boundary -2/2 Dangerous conditions of unburned explosive gases can occur in a number of ways including: Improper purging with N2 at start up and shut down A faulty start up sequence (with manual light up or auto-igniter) Operating under vacuum (air can leak in) Poor control during normal operation; crossing of the stoichiometric boundary When the stoichiometric boundary of 1.0H2/1.0Cl2 is crossed to say 0.9H2/1.0Cl2 what remains near the burner is now ~95% HCl gas with ~5% excess Cl2 and other inerts from the feed gas streams After the absorption of HCl in water, what remains in the gas stream sent to the tail tower is 70% to 90%V Cl2 with inerts; If the crossing occurs suddenly, a slug of Cl2 can now meet with a slug of H2 in the system and an explosion can occur and an emission of Cl2 will also occur We will now discuss what MERSEN does to minimize these conditions 12

MERSEN Material Selection MERSEN Graphite material (named Graphilor 3 ) is conductive (non-sparking), highly corrosion resistant; it is composed of ultra fine grain isostatic graphite (<20µm) for excellent mechanical resistance. Graphilor 3 XC can withstand up to 430 deg C ; it is used in high temperature areas --- this provides additional safety if there is an upset PTFE lined pipe (named ARMYLOR ) with graphite powder is conductive material for anti-static protection FRP equipment (like scrubbers or tanks) where H2 gas can be present use interior carbon veils (grounded to the exterior) for anti-static protection 13

MERSEN design top fired design 1. Burner + Reactor + Absorber encompassed in one piece of equipment 2. Wetted wall furnace design with optimized flame velocity & immediate liquid mass transfer (absoption) of acid permits reduced volume of gas in the unit translates to a reduced explosive volume & increased safety 3. Hydrogen gas (volatile gas) & chlorine is far above the ground (above the pipe rack) ATEX area far above the ground. 4. Chlorine gas is far above the ground (> 10 meters elevation). Top firing technology = Best design for Safety. 14

MERSEN safe design of ancillary devices and equipment 1/3 PILOT BURNER 1. Flame detection (SIL3 & ATEX certified) 2. Rupture disc (in Graphilor 3 ) with breakage detection low pressure design. FLAME DETECTOR 3. Flame arrestor (ATEX & ISO-16852 certified). 4. Pilot burner (for automatic ignition) with integrated transformer 5. Burner head temperature sensor / interlock BURNER HEAD TEMPERATURE SENSOR 15

MERSEN safe design of ancillary devices and equipment 2/3 Top fired means that a Catch Tank can be installed at the bottom to collect effluent when rupture disk breaks Safely handles gaseous and liquid effluent MERSEN s discharge of gas is typically less than 20% that of competitors that use an upfired design 16

MERSEN safe design of ancillary devices and equipment 3/3 Double block & bleed on Hydrogen line. Positive pressure start up with an air combustion blower to avoid vacuum Flame extinguishment package on the stack Possibility to install caustic scrubber package for ultra-low emissions. Instrumentation package for safe start-up & operation (ATEX & SIL2 certified where possible) 17

MERSEN control philosophy and HAZOP/ LOPA reviews Careful attention must be given to the control philosophy including a safe start up of the unit. START - UP PRODUCTION SHUT - DOWN Confirm multiple permissives Circulate cooling water Nitrogen purge ( 4 to 9 min)- BMS Circulate absorption water Introduce air ( by compressor or fan) Ignite pilot and main burner (H 2 or propane with air ) use automatic ignitor through BMS Substitute air with chlorine Set H 2 / Cl 2 ratio Change H 2 flowrate (or mtpd) Chlorine follows absorption water follows A proactive system with very little change in acid concentration : absorption water flow changes as soon as chlorine flow changes (*). BMS Safety interlocks (multiple interlocks tied to DCS or PLC process control system) SAFE AND REMOTE MINIMAL OPERATOR INTERFACE ALWAYS SAFE (*) : for plants where chlorine purity varies, a %HCl concentration meter can be added to correct the absorption water flowrate. 18

MERSEN control philosophy and HAZOP/ LOPA reviews HAZOP or LOPA review meetings are a must for any new installation A HAZOP is only as good as the people participating in it MERSEN has over 600 units installed and has some of the most experienced engineers on the planet when it comes to the design, installation and operation of HCl synthesis units If you are installing MERSEN equipment or a MERSEN system, make sure you get MERSEN, with all its experience, participating in your HAZOP 19

MERSEN process control & selection of control elements Careful selection of the gas flow meters and control valves (for air, H2 & Cl2) are paramount for a good control system Special consideration is required for the typical low pressure & corrosive feed conditions that prevail for most new systems that use low pressure gas direct from the electrolysis cells In general, the higher the pressure drop across a meter or control valve the better the turn down and controllability MERSEN carefully selects low dp meters and matches them to a suitable control valve that can handle all of the process conditions including start up transitions Often pressure recovery meters (such as dp venturis) are used to better enhance controllability, especially for wet low pressure Cl2 Control algorithms for the meters need to match accordingly CL2 venturi dp flow meter 20

MERSEN process control & selection of control elements Typical Chlor-Alkali plant Wet chlorine (Cl 2 ) MERSEN Sintaclor package CHLORINE DEMISTER HYDROGEN DEMISTER Wet hydrogen (H 2 ) Cooling Water COOLER COOLER Cooling Water WET Chlorine (Cl 2 ) Hydrogen (H 2 ) Brine Brine (NaCl) Depleted Brine Saturated Brine Cl 2 H 2 anode + _ MEMBRAN E cathode ELECTROLYZER Caustic Soda (NaOH) 21 If the compositions change and are not detected and corrected in the meter and control algorithms, explosions can occur.

MERSEN process control & selection of control elements MERSEN partners with AppliTek to offer their expertise with on-line analyzers - Hydrogen (H 2 ) and Chlorine (Cl 2 ) analyzers On-Line measurement of oxygen (O 2 ) content in chlorine (Cl 2 ) feed especially important for sniff or weak gas Also an indication of the membrane quality / lifetime Must adjust hydrogen consumption (H 2 +Cl 2 2HCl and 2H 2 +O 2 2H 2 O) to avoid excess of chlorine OR overconsumption of hydrogen On-Line measurement of oxygen (O 2 ) content in hydrogen (H 2 ) feed to keep the gas within the flammable limits to avoid a possible explosion - Measurement of other inerts in H 2 Sabic Innovative Plastics BoZ The Netherlands Add-on to H2 in WET Cl2 Westlake Vinyl Company LP Geismar LA USA New chlorine plant project If the compositions change and are not detected and corrected in the meter and control algorithms, explosions can occur. 22

MERSEN process control & selection of control elements If flow meters and their algorithms are not correctly engineered and calibrated, flow calculations will be in error Very dangerous when trying to operating with low excess H2 An upset condition can be disastrous and lead to the crossing of the stoichiometric boundary and an explosion can occur Most older installations (prior to installation in ~2005) have major meter issues and control issues that have or can lead to incidents These need to be corrected Additionally, where wet feed gases are being used directly from the electrolytic cells, flow meter algorithms and controller algorithms need to compensate for changing saturated conditions (V%H2O in gas stream) and or changing compositions as a result of membrane ageing or process upsets most important for the H2 stream Since the MW (molecular weight) of H2 is so low, any change in V% of H2O in this stream will greatly affect the MW and then affect the meter reading and the H2 controller set point algorithm This is also an accident waiting to happen If the compositions change and are not detected and corrected in the meter and control algorithms, explosions can occur. 23

MERSEN process control & selection of control elements MERSEN offers its audit and engineering services to find and correct these errors LOCAL AFTER-SALES CENTERS Consulting Upgrade Troubleshooting Start-up Services SPECIALISTS TEAM DIAGNOSTICS REPAIR ON SITE OR IN LOCAL WORKSHOPS Corrective Maintenance Preventive Maintenance UPGRADES 24

MERSEN s BMS Burner Management System Before 1990, almost all HCl synthesis systems started under vacuum manually and blind... Most incidents (burner pops or explosions) historically have happened and are still happening during the light up (start up) It is about time that we move out of the dark ages and establish a safe & scientific start up system 25

MERSEN s BMS - a major safety development Burner Management System. What does it do? Safely purges the system with nitrogen at start up & shut-down of burner Sequence burner ignition through safe start-up Supervise safety limits during operation Supervise the flame presence during operation Sequence a safe shutdown at end of cycle Integrate with the process control system for proper fuel (H2) and oxidizer (Cl2 and/or air) flows 26

MERSEN s BMS-integrate to the DCS Burner BMS Local Panel Controller (DCS) : Set point, Start/Stop mode, programming, auto-mode, capacity increase, change process variables. (In the Process Industry, Controller is often a DCS = Distributed Control System or a PLC= Programmable Logic Controller in a control room) Burner Management System : MERSEN BMS can be located at the unit or in a clean area or control room - Typically it integrates (handshakes) to the control system (DCS) via DCS programming 27

MERSEN s BMS Burner Management System other objectives BMS should be separate from any other control system and must be fail safe. NFPA86 & EN-743 have strict guidelines on what can be used as the safety devices within a BMS For NFPA, flame detectors, temperature interlocks & safety shut-off valves shall be listed for combustion safety service or approved if a listed device is not available listed means it has been tested and certified as safe for use by a Listing agency (like UL, CSA, FM, CE, etc.) approved means device has been evaluated by the owner or an outside authority (like an insurance underwriter) and is approved for service but does not necessarily carry a stamp or listing MERSEN takes the approach to use listed devices wherever possible to avoid further headaches ( approval process ) for the owner BMS PANEL PILOT BURNER 28

MERSEN s BMS-Combustion Safeguard Burner Management System Combustion Safeguard The combustion safeguard (logic solver) is. the key safety brains for the system It can either be a listed device or a PLC (programmable logic controller) that meets additional requirements as set forth in NFPA86 section 8.4 MERSEN uses a listed Honeywell combustion safeguard microprocessor based system PLC s if used need to be third party certified to IEC 61508 and have a minimum SIL2 rating many other stipulations are required for PLC s or safety PLC s this can put very onerous responsibilities on the owner & will be much more expensive The Honeywell system is well suited to a single burner system such as that used in a MERSEN HCl synthesis unit system s BMS package 29

MERSEN s BMS-Interlocks Burner Management System interlocks BMS PANEL EXTERIOR The combustion safeguard (logic solver) is the key safety brains for the system. but is not the entire system many other components make up the package including many safety devices and interlocks in the field that mate to the logic solver to form a fail safe package BMS PANEL INTERIOR includes pressure switches, flow switches, valve position limit switches, etc. which are hardwired into the BMS control panel package AUTO-IGNITER INSTRUMENT PACKAGE The BMS panel design integrates all of these interlocks with the logic solver 30

MERSEN s BMS- additional safety devices required for a safe system 31

MERSEN s BMS- recent references in the world EUROPE : (5) France : 3 Germany : 2 AMERICA : (15) Argentina : 1 Canada : 4 Peru : 2 USA : 10 BMS packages linked with fully automatic start-up. Customized automation for each project. ASIA / OCEANA: (5) Indonesia : 3 Korea : 1 ; New Zealand: 1 MIDDLE-EAST : (5) Kuwait : 1 Qatar : 2 UAE : 2 SAFETY : Exclusivity : Mersen s Burner Management System (BMS) is the only safety protection according to EN 746-42 industrial thermoprocessing equipment / Safety requirements for combustion and fuel handling systems and/or NFPA 86. Mersen s BMS can be TÜV, CSA or other approval agency certified. 32

CONCLUSION SAFETY SHOULD NEVER BE AN OPTION BMS is like ABS brakes or passenger AIRBAGS when you purchase a car! A BMS protects your assets MERSEN IS THE ONLY ONE TO HAVE STUDIED, ENGINEERED, DEVELOPED AND SUPPLIED BMS PACKAGES FOR HCL BURNERS MERSEN IS THE LEADER DEDICATED TO CONTINUOUS SAFETY & OPERATIONAL IMPROVEMENT MERSEN safety enhancements Material selection Safe equipment design Control philosophy and Safe practices Process control & selection of control elements BMS- Burner Management System 33

If you need an HCl production unit, you need to discuss the safe choices offered by THANK YOU FOR YOUR ATTENTION November 2016 Buenos Aires W. Wayne MOROZ, P.Eng. MERSEN Chemical Equipment Division Global Sales Engineered Systems wayne.moroz@mersen.com +1 540 389 7535 34