Plasma Low Temperature Sterilization. With vaporized hydrogen peroxide. PlazMax Line

Similar documents
Automatic Tabletop Autoclaves

BSL3 and BSL4 Autoclaves. Laboratory Line

Partnership. Medical Waste Autoclaves. Medical Waste Autoclaves

Automatic and Manual Autoclave Series. Tabletop Line

ENDOSCOPIC REPROCESSING ETD DOUBLE Advancing the Efficiency of Reprocessing.

A UT OCL A VE VE OCLA UT A _AutoClave_D1102EN_1703.indd /03/01 13:45

BEST PARTER & BEST SOLUTION RENO Plasma Sterilizer

Sterilization. Euronda Spa t (+39) m euronda.com

MEDICAL TRADING knows the meaning of sterilization very well: it can be

Steam Sterilizer. SA Series. for hospitals, CSSD and medical centers

GRAVOTECH GROUP. Complete range of Integrable Fiber Laser Marking Solutions LASER SOLUTION F-SERIES.

TRACECARE Monitoring, Reporting & Traceability Solutions

PRODUCT CATALOGUE. for gke Steri-Record and gke Clean-Record Chemical indicators, PCDs and accessories for cleaning and sterilization

FITOCLIMA WALK-IN STABILITY

testo 330 Flue gas analysis with increased convenience and safety

gke Steri-Record Testsets and PCDs for validation, process and batch monitoring of sterilization processes

B Futura and B Classic. The curtain goes up on reliability.

Thermoforming packaging machine R 145 with MULTIVAC Clean Design. Maximum process reliability and cleanroom suitability

Steam Sterilization Monitoring in the New CSA Standard (Z )

Best Selection for Your Business. Electronic Pricing Scale. User s Manual. (Model: TP-31)

EBI 10 High Precision Wireless Data Loggers

Dental X has been synonymous with Italian excellence in sterilisation since Almost forty years side by side with dental professionals, who find

Dornier Medilas H Solvo and UroPulse Leading Holmium Lasers in Endourology

Thermo Scientific Sorvall BIOS 16 Centrifuge. performance simplified. at every turn

Competency Guide: Care and Handling of Rigid Endoscopes

Fluke Oscilloscope Calibration Solutions. Helping you measure up to the highest standards

INTRODUCING OUR SELF SERVICE SOLUTIONS FOR TICKETING

VERTICAL AUTOCLAVE DELUXE. MODEL NO.- Acm A

xdental x the sterilization company Domina Plus B Aptica Plus B Atoma Plus

ABILITY - IDENTIFICATION - TRACEABILITY - IDENTIFICATION - TRACEABILITY - IDENTIFICATION - TRACEABILITY - IDE

NovaWAVE. A new category of Automated Microwave Digestion

TEMPERATURE CHAMBER (+5 C +180 C) TK-50 CK TK-105 CK TK-190 CK TK-340 CK TK-500 CK TK-1000 CK

GRAVOTECH GROUP FIBRE LASER. Complete range of integrable laser marking systems LASER SOLUTION F-SERIES.

series HSD Steam sterilizer EUROSTEAM Medical device

Model BF 720 Incubators Avantgarde.Line with forced convection

Boost turnaround time for faster diagnosis

CARESTREAM DIRECTVIEW Max CR System

ebro Validation-Set for large Steam Sterilizers SL 2100 The Set contains:

Combustion Laboratory Unit C492

Bar Scan tracks fixed assets in a cost effective manner using the latest handheld technology.

Tissue Microarray Catalog

Thermal Shock Test Chambers TS Series

LabX Software. Complete Overview, Total Control Smart Laboratory Instrument Software. LabX Software. LabX balance LabX titration LabX connect

The. universal 3D Inspection reference. advanced 3D measurement software & solutions

FREQUENTLY ASKED QUESTIONS FOR THE ADVANTAGE

Fast. Easy to use. Secure traceability.

Performance with a single touch

Instrument specifications Technology Software Host interfaces Printer interfaces Data Station Physical dimensions Weight Certifications

Machine modernization directly from the CNC manufacturer increasing efficiency and economic feasibility siemens.com/motioncontrolservices

IH-1000 Fully Automated System for ID-Cards

TSXV : DM HARNESS THE VALUE OF YOUR SALES DATA. Connects to any POS. Datametrex DataTap. Robust Dashboard

Explore the future of osmometry. Multi-Sample Micro-Osmometer

PRESENTS A RFID THE JANUS* GATE: RFID TERMINAL SYSTEM FOR CONTAINERS CCCCCONTAINERS CONTAINERS RFID NEPTUNESEAL * CONTAINER BOLT SEAL

ADVANTAGE PLUS Pass-Thru Endoscope Reprocessing System

Passport POS. Point-of-Sale Systems for C-Stores. No site like yours. No system like ours.

Model BF 260 Incubators Avantgarde.Line with forced convection

YSI 2900 Series Biochemistry Analyzers BIOPROCESS FOOD & BEVERAGE BIOFUELS MEDICAL RESEARCH

Avitar Clerk Electronic Invoice Presentment & Payment

RIGID ENDOSCOPE OPERATING INSTRUCTIONS

Compact flue gas analyser: testo 300 M-I

Packaging Systems for Central Service Operations

Application for Container Shipment Hospital Sisters Mission Outreach

Data Logging Solutions from Lascar Electronics

Camera Eyepiece. User s Manual. KS035200G4-Ver1.0

Choose the best device for your scanning needs

AP-25 Plasma System AP-25 PLASMA THERMAL SPRAY SYSTEM

ECO INSTRUMENT (NS M)

Getinge da Vinci Solution

Measurement & Analytics Measurement made easy. AlSCAN TM and AlSCAN TM Argon Hydrogen analysis in liquid aluminum

Asset Management. Visit us at: or call SCAN

HI Multiparameter Photometers with up to 44 Measurement Methods. ISO 9001:2000 Certified

VDO RoadLog. ELD Compliance Fleet Management Compliance Reporting. VDO and RoadLog Trademarks of the Continental Corporation FMCSA

MonTech RP 3000 Rapid Plastimeter for Polymers and Natural Rubber

EVERLINE LED Linear High Bay Luminaires (BLC48) Wally Creer Director of Product Management, Luminaires

Online Gas Analyzer / Monitor

PAYMENT EXPRESS EFTPOS GETTING STARTED GUIDE. Version 0.2

LEADING TECHNOLOGY IN STERILIZATION

AS/NZS 4187 RELEVANT STANDARDS. Robyn Williams NUM CSSD LBHHS & Standards Australia Chair HE-023

SIWAREX FTC The belt scales in SIMATIC More than just standard. siwarex ftc

Audion Medical. Impulse & vacuum Rotary sealers Heat sealer Packaging standards Measuring devices

ENDOSCOPIC ULTRASOUND CENTRE EU-ME2. Dedicated ultrasound processor with versatile functions.

ES 3 / 7 / 8000 Interactive Management in Price Labelling

Atlas Copco. High-pressure oil-free air piston compressors P 37 - P 160 / 25 to 40 bar / 37 to 160 kw

GETINGE 633HC STEAM STERILIZERS. Always with you

Dictate and transcribe immediately. Anywhere. Any time.

I N F I N I T Y Z U C C H E T T I ACCESS MANAGEMENT

FiberCab Laser Cutting Solutions

FLEETMATE Enterprise Edition. Fleet Maintenance Software. Enterprise Edition. a better way to manage maintenance

FedEx Ship Manager. Software. Version Quick Guide

Gridless end-hall. Ion Sources. For Ion Assisted Thin Film Deposition & Substrate Cleaning

imvision System Manager Infrastructure Management Software

Test record CFU measurement. Test ID Site/Clinic Spijkenisse

// The powerful All-Rounder for your Quality Assurance: ipq-center. Be inspired. Move forward.

Agilent 1260 Infinity RID User Manual. 9 Maintenance

Advances in hydrogen peroxide gas plasma sterilization

Model FD 115 Drying and heating chambers Avantgarde.Line with forced convection

Low Temperature Testers

viscount systems ENTERPHONE Intelligent Telephone Entry Solutions

Transcription:

Plasma Low Temperature Sterilization With vaporized hydrogen peroxide PlazMax Line

Low Temperature Sterilization PlazMax Line For heat and moisture sensitive equipment PlazMax provides an efficient sterilization solution for heat & moisture sensitive equipment in CSSDs and Gastroenterology & Respiratory Endoscopy Clinics. With PlazMax you get increased productivity, reduced risk of work stoppage, and efficient supply of sterilized equipment where it s needed. In operating rooms PlazMax benefits you with almost immediate access to sterilized equipment. Simple to install and control, only requiring 1-phase electricity and Hydrogen Peroxide (H 2 O 2 ) packs to operate. No need to send equipment to a CSSD, eliminating the risk of damage and contamination in transit. 2

PlazMax Line Advanced and Flexible Control System Take Advantage of Tuttnauer s state-of-the-art control system with multicolor touch screen display. Includes equipment tracking and maintenance notification features. 25 minutes Fast and Productive PlazMax cycle times are as low as 25 minutes (P50 normal cycle). Wide Range of Chambers Don t over pay for two small sterilizers when you can buy one large sterilizer. Choose from 3 models with chamber sizes from 47 to 109 liters. Keep Running Costs Low Keep you consumable costs low With PlazMax you have the freedom to use commonly available market accessories such as indicators, pouches & rolls, etc. that are suitable for sterilization with vaporized hydrogen peroxide. Tuttnauer also sells sterilant, and biological indicators & chemical indicators. Clean Technology Non-toxic sterilizing agent Minimal utility requirements low electricity consumption, no water consumption The sterilization process results in water and oxygen by-products Vertical Sliding Door Automatic Vertical Sliding Door with built-in foot operated device for hands-free door operation. Tough Challenges PCD By challenging the PlazMax sterilizer with our Process Challenge Device (optional) you will be confident that it does its job at the highest sterilization levels. 3

PlazMax P50 180mm 47 Liter Chamber Single or Double door Chamber Dimensions (WxHxD) 420 x 180 x 624 mm PlazMax P80 320mm 83 Liter Chamber Single or Double door Chamber Dimensions (WxHxD) 420 x 320 x 624 mm 4

PlazMax Line PlazMax P110 420mm 109 Liter Chamber Single or Double door Chamber Dimensions (WxHxD) 420 x 420 x 624 mm Technical Specifications M o d e l Volume Liters Chamber Dimensions (WxHxD) mm External Dimensions (WxHxD/D 2-doors) mm No. of Baskets 40x60 (WxD) cm Power (W) Current (A) Voltage (V) 1-Phase 50-60 Hz P50 47 420 x 180 x 624 702 x 1528 x 729 / 736 1 P80 83 420 x 320 x 624 702 x 1668 x 729 / 736 2 P110 109 420 x 420 x 624 702 x 1768 x 729 / 736 2 3100 W 13.5 A 3400 W 14.7 A 4300 W 18.7 A 230 V 230 V 230 V Sterilization Cycle and Test Programs Model Normal Cycle (Non-hollow loads) Advanced Cycle (Hollow loads) Endoscope * Cycle Time (min.) Cycle Time (min.) Cycle Time (min.) P50 35 40 28 P80 35 40 28 P110 45 50 30 Test Cycles Test I Test II Description Penetration Test Leakage Test * Endoscope cycle temperature: short heating time and reduced H 2 O 2 exposure time. Note: Cycle times are based on a hot cycle and may vary according to load volume. 5

Advanced Control System for Your CSSD Take advantage of Tuttnauer s sophisticated user-friendly control system for repeatable high performance. Standard Features 7 Multi-color touch screen panel (also on second door of two door configurations) Stores the last 200 cycles in built-in memory Multiple access levels and user passwords to control access/ operation of the Plazmax Diagnostic In/Out test (enables technician to check each system component separately) Sterilization Temperature range 50 C to 55 C Thermal Printer USB and Ethernet connection port Sophisticated Touch Screen HMI The HMI (Human Machine Interface) has been designed with the following considerations: Multi-color display for easier reading from a distance Multilingual (26 languages) Dynamic graph displaying the chamber pressure and the cycle process Displays process info pressure, temperature, vaporizer temp. Equipment Tracking & Maintenance Notification Equipment tracking software provides a detailed sterilization history of each endoscope tracked. The software will notify when equipment needs to be returned back to the original equipment manufacturer for maintenance. Handle Endoscopes ID Name Max Current Total Last Init 1 BF 1 T 160 70 10 100 2/SEP/2013 2 BF 160 70 15 150 2/SEP/2013 3 CF Q 160 AL 100 12 224 2/SEP/2013 4 CF 2 T 160 L 70 18 321 2/SEP/2013 5 PCF 160 AL 100 10 154 2/SEP/2013 6 GIF Q 160 70 15 117 2/SEP/2013 7 GIF XP 160 100 10 258 2/SEP/2013 8 GIF PQ 20 70 13 132 2/SEP/2013 SELECT INIT REMOVE NEW... Not Ready 09:31:32 6 th October, 2013 6

PlazMax Line R.PC.R Software Automatic Recording of Cycle Information to Your PC Reporting You Can Rely On Automatic recording of cycle information to any PC on your network Convenient access to graphs and tables that are easy to understand Easily generate PDF reports No need to file printouts, saving you time Be in Control with Real-Time Remote Monitoring See the real-time autoclave display on your PC Monitor all activity for up to 8 sterilizers With R.PC.R you can see: Graphs of the cycle data, Numeric cycle data, cycle print-outs, measured values table, parameter table. Software and Hardware Standard Direct network access for technical Support (requires R.PC.R) Touch screen Thermal Printer Optional Remote network access for technical Support (requires R.PC.R) (requires local SIM card for Internet connection) R.PC.R software for access from PC or network USB Digital Cycle Data Connect a USB memory device to the PlazMax and you can download a soft copy of cycle printouts and all cycle data history stored in the sterilizer s memory. 7

8 Sterilization Cycle Process

PlazMax Line How can you be sure your hollow instruments have been 100% penetrated? Use Tuttnauer s Process Challenge Device (PCD) Tuttnauer s PCD kit includes lumens that are more difficult to penetrate than your loads. With the PCD you can be certain your lumen loads, like endoscopes, are fully exposed to the vaporized hydrogen peroxide sterilizing agent. The PCD kit includes long lumen configurations that cannot be successfully sterilized in many competing devices. The PCD Kit includes 1mm diameter lumens with lengths of 4m (both sides open) and 1.4m lumens (one side open). 1.4m one side open 4m both sides open Chemical indicators are used every cycle and in each packed item to validate penetration and to ensure vaporized peroxide has made contact with the load. Biological indicators are used according to a schedule required by a hospital s policy and require an incubator (optional) to facilitate the detection of micro-organisms. Biological indicators validate sterilization by helping determine that the sterilizer effectively kills the micro-organisms. Safety Features Tuttnauer strives to provide sterilizers that ensure safety for patients, staff, and the environment. Safety features include: No hazardous or odorous emissions Low temperature and low pressure during sterilization Door is locked during cycle operation 9

Non-Hollow Loads Non-hollow loads are sterilized with the Normal Cycle. Electrocautery Instruments Dopplers Laser probe Defibrillator paddles Thermometer Ophthalmic lenses Harmonic cable Hollow Loads Hollow loads are sterilized with the Advanced Cycle. Laryngscope blade Shaver hand pieces Fiber optic light cable Surgical power drill Laryngscope & blades The instruments and equipment presented are only a partial list of the wide range that can be safely sterilized in PlazMax Only use PlazMax with equipment authorized by original manufacturer to be sterilized with plasma sterilizers. 10

PlazMax Line Endoscopes Endoscopes and similar equipment are sterilized with the Endoscope Cycle. Rigid scope for optics Rigid scope Flexible endoscope Flexible endoscope 11

Standards and Directives PlazMax has been developed according to the following international standards and directives (partial list): ISO 9001:2008 ISO 13485:2003 ISO 14937 EN 61010-2-040:2005 EN 60601-1:2006/AC:2010 Medical Device Directive 93/42/EC CE Medical Device Mark 0344 Your Sterilization & Infection Control Partners Company Profile For over 88 years, Tuttnauer s sterilization and infection control products have been trusted by hospitals, universities, research institutes, clinics and laboratories throughout the world. Supplying a range of top-quality products to over 100 countries, Tuttnauer has earned global recognition as a leader in sterilization and infection control. Global Partnership At Tuttnauer we feel that business means people dealing with people. We pride ourselves on our reputation for having long-lasting relationships with our customers based on commitment and trust, spanning over decades and distances. Our Flexibility is Your Advantage Beyond our wide range of products and ability to customize products to customer requirements, we also manage complete turnkey solutions, including planning, design and installation of equipment, as well as consultation and feasibility studies, for projects of all sizes. PlazMax Line International Sales and Marketing E-mail: info@tuttnauer-hq.com www.tuttnauer.com Tuttnauer Europe b.v. Hoeksteen 11, 4815 PR P.O.B. 7191, 4800 GD Breda The Netherlands Tel: +31 (0) 765 423 510, Fax: +31 (0) 765 423 540 E-mail: info@tuttnauer.nl Tuttnauer USA Co. 25 Power Drive, Hauppauge, NY 11788 Tel: +800 624 5836, +631 737 4850 Fax: +631 737 0720 E-mail: info@tuttnauer.com Distributed by: LTR330-0061/PLASMAX/V-5/1.14 A