COMMERCIAL ROOFING SYSTEMS

Similar documents
Thermoplastic Single Ply & Multi-Ply Roofing Systems

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Roof Replacement. Notes: T-1 (Title Sheet) Roof Key Plan Russell House Student Union 1400 Greene Street Columbia, South Carolina 29208

SECTION STYRENE-BUTADIENE-STYRENE (SBS) MODIFIED BITUMINOUS MEMBRANE ROOFING

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

COMMERCIAL BUILDING APPLICATIONS

ACFoam-II HCFC Free "Green" Polyiso Specification

Sure-Weld (TPO) Adhered Roofing Systems Code Approval Guide January, Table of Contents

ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION

HALIFAX HUMANE SOCIETY BOARDING AND GROOMING FACILITY SECTION STYRENE-BUTADIENE-STYRENE (SBS) MODIFIED BITUMINOUS

SECTION SELF-ADHERING SHEET WATERPROOFING

Thermoplastic Metal Retrofit Roofing System

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MODIFIED BITUMINOUS SHEET ROOFING REPORT HOLDER:

1. Decks, balconies, and sun porches 2. Walkways, ramps, and stairways 3. Patios and courtyards

CITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO

Exterior Research & Design, L.L.C. Building Science and Envelope Consultants

EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization # Christian Street Oxford, CT PHONE: (203) FAX: (203)

LEGACY REPORT DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FLUID APPLIED ROOFING REPORT HOLDER: CONKLIN COMPANY INC.

WATERPROOFING TAMKOWATERPROOFING.COM

TPO and PVC Roof Flashings and Accessories

UL Evaluation Report UL ER Issued: July 25, UL Category Code: ULFB. CSI MasterFormat

SBS Hot-Mopped & Cold Adhesive Roofing (COMGN289) Updated: 1/17

Roofing Insulation Products The Trusted Leader in Polyiso Roofing Insulation Solutions

PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

VINITEX INSTALLATION PROCEDURES

MAKE ROOFS LAST LONGER

REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC 250 WEST 96 TH STREET INDIANAPOLIS, INDIANA EVALUATION SUBJECT:

Put OMG in your plans. DRAINS FASTENERS PIPE SUPPORTS

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

Hot Mopped / Cold Applied Adhered (VersiFleece AC TPO) Mechanically Attached Roofing System (VersiFleece AC TPO/VersiFleece AC EPDM)

MULE-HIDE PRODUCTS CO., INC. MULE-HIDE SELF-ADHERING TPO ROOFING SYSTEM

SECTION Hybrid Fully Adhered Single Ply Roofing Systems

ASSEMBLY DESIGN CRITERIA

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ETHYLENE PROPYLENE DIENE MONOMER ROOFING REPORT HOLDER:

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY

SECTION MANUFACTURED ROOF EXPANSION JOINTS

APPLICATION SAFETY TOOLS REQUIRED

F i r e s t o n e U l t r a P l y T P O P R E M I U M P R O T E C T I O N. P R O V E N P E R F O R M A N C E.

SECTION PREPARATION FOR RE-ROOFING

The Original. The Innovator.

Mechanically Attached and Fully Adhered Roofing Systems. Part I Design Criteria

TEKTON Flashings and TEKTON Construction Tape

2010 FLORIDA BUILDING CODE TEST PROTOCOLS HVHZ (TAS)

FLUID APPLIED WATERPROOFING

SL175 Panel Technical Data Guide

TOPCOAT Product Catalog

Roof Repair Sealants

Product Technical Bulletin APS-5T

.1 Provide submittals in accordance with Section Submittal Procedures.

FIRESTONE ULTRAPLY TPO SA APPLICATION GUIDE

Application Guide. Single Ply Roofing Systems (PVC) Section 1- Introduction

Firestone RubberGard The EPDM reference

LOW SLOPE ROOFING INSTALLATION

ESR-1365 Reissued March 2014 This report is subject to renewal April 1, 2015.

SECTION G RELIEF VENTS A-0

GardenScapes Hassle-Free Garden Roofing

Firestone Polyiso Boards

Product Technical Bulletin SPM-4H-250

Recommended Fastening Patterns for Rmax Insulation in Low Slope Roofing Applications

Sure-Seal /Sure-Weld FleeceBACK AFX Cold Applied Adhered Roofing System

Weatherproofing & Sealing Systems

PLATON FOUNDATION WRAP

SECTION PVC SINGLE PLY ROOFING

SPECIFICATION SUBMITTAL

EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization # Christian Street Oxford, CT PHONE: (203) FAX: (203)

Mechanically Attached and Fully Adhered Roofing Systems

Design & Construction Standards, Revised January

SPECIFICATION AND DETAIL GUIDE

RUBBERGARD EPDM SA APPLICATION GUIDE

Design No. P922 September 26, Restrained Assembly Rating 1, 1-1/2 or 2 Hr (See Items 6, 7) Unrestrained Assembly Rating 0 Hr (See Item 6)

Modified Bitumen Roofing Systems Simplified Approach to Commercial Low Slope Roofing

UL Evaluation Report UL ER Issued: December 9, Revised: September 29, UL Category Code: ULFB. CSI MasterFormat

Roof Replacement Specifications Section METHOD SPECIFICATONS, ROOF REPLACEMENT AT THE LOG COLLEGE MIDDLE SCHOOL. CENTENNIAL SCHOOL DISTRICT:

Worldwide Competence in Plastics. Development by professionals. The long-lasting roof system

COMMERCIAL ROOFING PRODUCTS

Put OMG in your plans.

Construction. Sarnafil TS Polymeric membrane for roof waterproofing. Product Description

NOVABRIK MORTARLESS CONCRETE BRICK VENEER SPECIFICATION. MASTERFORMAT SECTION (Mortarless Concrete Brick Veneer)

Construction. Sarnafil G Felt. Polymeric membrane for roof waterproofing. Product Description

City of Republic Community Development Department. Residential Roofs REVISION DATE: JANUARY 2017

UNIFIED FACILITIES CRITERIA (UFC) ROOFING

Roofing. Sarnafil S EL. Polymeric membrane for roof waterproofing. Product Description

Specification & Detail Guide

TOPCOAT Restoration Specifications Fiberglass & MB Granulated Cap Sheets

PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

NRCC Guarded Hot Box Testing (ASTM C ) for Energy Efficiency of a Total Roof Assembly

TOPCOAT Restoration Specifications Structural Concrete

1. SUBJECT: DURO-LAST, DURO-TUFF, DURO-FLEECE, and DURO-FLEECE PLUS ROOFING MEMBRANES

CARLISLE S FLEECEBACK ROOFING SYSTEMS DURABILITY PUNCTURE RESISTANCE LONG-TERM PERFORMANCE

QUALITY COATING & REPAIR PRODUCTS

Roofing. Sarnafil G EL Felt. Polymeric membrane for roof waterproofing. Product Description

Installation Products

Mechanically Fastened Guide Specification

SHEET METAL ROOF TEST REPORT

1 Exam Prep. Roofing Practice Exam 9

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

Roofing. Polymeric sheet for roof waterproofing. Product Description. Tests. Product Data Sheet Edition _1

Sarnafil Adhered Single-Ply Roofing Systems

Three Great Steel Panels

Transcription:

Flex Membrane International Corp. 2670 Leiscz s Bridge Road, Suite 400, Leesport, PA 19533 Tel: 610-916-9500 Fax: 610-916-9501 COMMERCIAL ROOFING SYSTEMS FLEX FB (Fleece Backed) ELVALOY, FLEX MF/R (Smooth Back) ELVALOY, FLEX FB PVC, AND FLEX MF/R PVC ADHERED, MECHANICALLY ATTACHED, AND BALLASTED APPROVED COMPONENTS LISTING The below listed materials are approved for use in conjunction with Flex FB Elvaloy, Flex MF/R Elvaloy and Flex MF/R PVC Roofing Systems for compliance with the standard five (5) year guarantee and optional, ten (10) year, fifteen (15) year, twenty (20) year and twenty-five (25) year guarantee programs. 1. Flex Roofing Membranes: All widths are approved. Type & Thickness Color Usage Guarantee Length Flex FB, FB Plus, White, Gray, Tan All 5, 10, 15, 20 & 25years FB 120 Elvaloy Flex FB 100 Elvaloy White, Gray, Tan All 5, 10, 15, 20 & 25years.100 total thickness Flex MF/R, MF/R Plus White, Gray, Tan All 5, 10, 15, 20 & 25years MF/R 120 Elvaloy Flex MF/R PVC White, Gray, Tan All 5, 10, 15, 20 & 25years.050,.060,.080 Flex Flashing Membrane White, Gray, Tan Flashings only Concurrent with Reinforced Field Membrane Non reinforced.045 Flex 6 Trim Strip White, Gray, Tan Trim Work Concurrent with.045,.060 Field Membrane Flexclad Metal White, Gray, Tan Where Concurrent with Required Field Membrane 2. Insulation: A. Polyisocyanurate faced roof boards: Per Federal spec. HH-I-1972/GEN and HH-1-1972/2, ASTM C 1289, Type II, Class 1, Grade 2 (20 psi) or Grade 3 (25 psi) minimum thickness 1 nominal. Flex ISO II, Flex ISO III, Flex ISO II Tapered, and Flex ISO III Tapered

B. Extruded polystyrene boards: ASTM C 578 Type X (18 psi) or Type IV (25 psi), CAN/ULC S701, Type 3, Nominal board thickness 2 C. Molded expanded polystyrene boards: ASTM C578-85, Type 1, minimum density 0.9 lbs. /cu.ft. Nominal board thickness 1 D. Perlite Insulation Board: ASTM C 728 Type I or Type II, nominal board thickness 1/2 E. Lightweight roof fills: Perlite, vermiculite, cellular concrete and gypsum. Used in conjunction with Flex approved separation layers. F. Wood fiber boards: ASTM C 208 Type II, Grade 1 or Type II Grade 2, nominal board thickness 1/2 G. Sprayed polyurethane foam: Minimum 2 thick and minimum 2.0 lbs. /CF density when used in conjunction with Flex approved separation layers and insulation boards. 3. Asphalt ( Elvaloy Fleeceback Membranes Only): A. Hot steep asphalt: ASTM D 312, Type III and Type IV B. Polymer Modified Asphalt: ASTM D 6152, Flex SEBS200 Modified Rubberized Asphalt 4. Fasteners: A. Metal /Wood Decks: Screw type fasteners treated with CR 10 corrosion resistant coating. Required pull out value of minimum 420 lbs. in 22 gauge steel deck to be applied in conjunction with a Factory Mutual approved pattern: 1. Flex Standard Steel/Wood Deck Fastener and Plate 2. Flex HD Steel/Wood Deck Fastener and Plate 3. Flex XHD Fastener and Plate 4. Flex SXHD Fastener and Plate 5. Flex Rhino Plate and Fastener B. Structural Concrete Decks: Minimum compressive strength of 2500 psi, Density of 150 lbs./cu/ft. Required pull out value of minimum of 600 lbs. 1. Flex CD-10 Concrete Fastener and Plate 2. Flex Fluted Nail Concrete Fastener and Plate 3. Flex Rhino Plate and Fastener C. Lightweight Insulating Concrete: Density of 20 to 40 lbs. /cu.ft. Minimum Compressive Strength of 200 psi. Required pull out value of minimum of 300 lbs. 1. On steel deck see 4A above. 2. Flex GypTec Fastener and Plate 3. Flex Lite Deck Fastener and Plate 4. Flex CR Base Sheet Fastener (pull out value 40 lb. min.) 5. Flex OlyLok Locking Impact Nail

D. Cementitious Wood Fiber, Gypsum: 1. Flex GypTec Fastener and Plate 2. Flex Lite Deck Fastener and Plate 3. Flex OlyLok Locking Impact Nail 5. Adhesives: A. Caulking: Silicon, polysulfide or polyurethane caulking, exterior grade for caulking, surface reglets and vent pipe details. 1. Geocel 3300 Polyurethane roofing sealant 2. Sonneborn, NP1 3. BOSTIK, Chem Caulk 4. ChemLink M-1 Structural Sealant B. For filling pitch pans: Flex Pourable Sealer or as approved by Flex Technical Services Department. C. Flashing Adhesive: As supplied by Flex Membrane for laminating flashing to vertical surfaces. D. Substrate Adhesive: As supplied by Flex Membrane for adhering FB Fleece Backed Membranes or Smooth Back membranes to approved substrates. E. Flex Modified Adhesive: As supplied by Flex Membrane for adhering modified bitumen membranes to insulation recover boards or to modified bitumen base sheets. F. Flex FB Low Rise Adhesive: A 2 part urethane foam adhesive for adhering Flex FB membranes to approved substrates 6. Nailers: Provide lumber for support or attachment of flashings, edge metals, and accessories. Include roof top equipment bases curbs and support bases. A. Number 3 or Standard Grade in accordance with ALSC NGR B. Preservative Treated in accordance with the requirements of AWPA C2 7. Separation Layers: All separation layers are for use over insulation and below membranes with Mechanically Fastened and Ballasted systems. Note: Red rosin paper and sheet polyethylene are not approved. A. Flex Separator Sheet B. Flex FR-10 and FR-50 Fire Retardant Slip sheet C. Flex Foil Barrier Slip Sheet for use over coal tar pitch roofs. D. Flex Rockwool Mat

E. Flex Green Guard 3/8 PB6W Fan Fold Roofing Recovery Board F. Georgia Pacific Corporation DensDeck, DensDeck Prime G. USG Securock H. Flex HS Coverboard High Strength ½ thick polyisocyanurate cover board 8. Adhered System Components: A. Flex Re-Cover Board: Asphaltic fiberglass recover board for use over most insulations or BUR roofs B. Flex 80 mil S/S Base Sheet: For use as the base or first ply in Flex s high performance Built Up Elvaloy or Modified Flex Roof Systems. C. Premium Flex Ply Roofing Felt: Fiberglass Type VI roofing felt. For use in Flex s high performance Built Up Elvaloy or Modified Flex Roof Systems. D. Georgia Pacific Corporation: DensDeck, DensDeck Prime E. USG Securock F. Flex HS Coverboard High Strength ½ thick polyisocyanurate cover board 9. Edge Termination Components: A. Flex Clad Metal: for custom fabrication of a hot air weldable edge metal B. FlexLock FLT Roof Edge C. FlexLock FLE Roof Edge D. FlexLock FLS Roof Edge E. FlexCap FLC Coping 10. Specialty Components: A. Flex Preformed Inside and Outside corners B. Flex Preformed Pipe Boots C. Flex Retrofit Drains with PVC Coated Flange D. Flex Walkway Pad E. Flex Insulvent with PVC Coated Flange F. Flex Snowguard PVC Coated

G. Flex 2 3/8 XHD Barbed Membrane Plate, and 2 ¾ SXHD Barbed Membrane Plate H. Flex 3 PVC Coated Rhinobond Plate I. Flex CR Base Sheet Fastener J. Flex Lip Termination Bar, Flex Flat Termination Bar K. Flex Standard Screws, Flex XHD Screws, Flex SXHD Screws L. Flex Split Pipe Boots M. Flex Preformed Curb Flashing 11. Ancillary Components: A. BAK Laron Automatic Welding Machine B. BAK Rion Hand Held Welding Tool C. Leister Varimat Automatic Welding Machine D. Leister Triac Hand Held Welding Tool E. Flex Hand Held Silicon Seam Roller F. Flex Seam Probe G. RhinoBond Induction Welding System