adhered. Membrane: Polyglass, ELASATOFLEX SA V FR, self adhered. Base Sheet: Polyglass ELASTOFLEX SA V FR BASE, self adhered.

Similar documents
SL175 Panel Technical Data Guide

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

Sure-Weld (TPO) Adhered Roofing Systems Code Approval Guide January, Table of Contents

Exterior Research & Design, L.L.C. Building Science and Envelope Consultants

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Modified Bitumen Roofing Systems Simplified Approach to Commercial Low Slope Roofing

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MODIFIED BITUMINOUS SHEET ROOFING REPORT HOLDER:

REPORT HOLDER: CARLISLE SYNTEC POST OFFICE BOX 7000 CARLISLE, PENNSYLVANIA EVALUATION SUBJECT:

ASSEMBLY DESIGN CRITERIA

REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC 250 WEST 96 TH STREET INDIANAPOLIS, INDIANA EVALUATION SUBJECT:

HALIFAX HUMANE SOCIETY BOARDING AND GROOMING FACILITY SECTION STYRENE-BUTADIENE-STYRENE (SBS) MODIFIED BITUMINOUS


UL Evaluation Report UL ER Issued: December 9, Revised: September 29, UL Category Code: ULFB. CSI MasterFormat

UL Evaluation Report UL ER Issued: July 25, UL Category Code: ULFB. CSI MasterFormat

TELEPHONE: (215) Addendum No. 1

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MODIFIED BITUMINOUS SHEET ROOFING REPORT HOLDER: POLYGLASS USA, INC.

Design No. P922 September 26, Restrained Assembly Rating 1, 1-1/2 or 2 Hr (See Items 6, 7) Unrestrained Assembly Rating 0 Hr (See Item 6)

Thermoplastic Single Ply & Multi-Ply Roofing Systems

Recommended Fastening Patterns for Rmax Insulation in Low Slope Roofing Applications

SECTION PREPARATION FOR RE-ROOFING

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY

Firestone Polyiso Boards

Impact Resistance What the Hail Is Happening?

PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Code Approval Guide. Underwriters Laboratories Factory Mutual. March 2005

The Building Envelope Solution. Mike Lowery A&D Products, LLC

EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization # Christian Street Oxford, CT PHONE: (203) FAX: (203)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ETHYLENE PROPYLENE DIENE MONOMER ROOFING REPORT HOLDER:

Design No. P921 April 16, Restrained Assembly Rating 1, 1-1/2 or 2 Hr (See Items 4, 6, 7 and 9) Unrestrained Assembly Rating 0 Hr (See Item 7)

ESR-1365 Reissued March 2014 This report is subject to renewal April 1, 2015.

1 Exam Prep. Roofing Practice Exam 9

WATERPROOFING TAMKOWATERPROOFING.COM

1. SUBJECT: DURO-LAST, DURO-TUFF, DURO-FLEECE, and DURO-FLEECE PLUS ROOFING MEMBRANES

American National Standard Standard Field Test Procedure for Determining the Withdrawal Resistance of Roofing Fasteners

PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

COMMERCIAL BUILDING APPLICATIONS

REPORT HOLDER: FEROOF CO., LTD SEONWON LI SEONNAM MYEON SUNGJU GUN KYEONGSANGBUK DO SOUTH KOREA EVALUATION SUBJECT:

J. Paul Guyer, P.E., R.A.

SPECIFICATION SUBMITTAL

statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.

Roofing Insulation Products The Trusted Leader in Polyiso Roofing Insulation Solutions

SECTION SBS-MODIFIED BITUMEN MEMBRANE ROOFING HEAT-WELDED

PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

FIRESTONE RUBBERGARD. EPDM: The roofing membrane for the 21 ST CENTURY.

technical bulletin ROOFING CORPORATION

Sarnafil Adhered Single-Ply Roofing Systems

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Building Envelope Systems Exam Learning Objectives

EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization # Christian Street Oxford, CT PHONE: (203) FAX: (203)

CARLISLE S FLEECEBACK ROOFING SYSTEMS DURABILITY PUNCTURE RESISTANCE LONG-TERM PERFORMANCE

FIRESTONE RUBBERGARD EPDM

EVALUATION REPORT Soprema, Inc. 310 Quadral Drive Wadsworth, OH 44281

Common Applications: FRT plywood Type X Gypsum wall board

SECTION STYRENE-BUTADIENE-STYRENE (SBS) MODIFIED BITUMINOUS MEMBRANE ROOFING

ISO Types 1-6: Construction Code Descriptions

NOTES FROM THE FIELD FLAT ROOFS AND MASONRY IN NEW YORK PETER MARCIANO

TOPCOAT Product Catalog

Understanding the puncture resistance of TPO membranes. Sarang Bhawalkar, Tammy Yang, Thomas J. Taylor

SECTION PVC SINGLE PLY ROOFING

Insulated Panels. Insulated Roof Systems. Kingspan X-dek. KS1000 XD Longspan Roofpanel. Systems. Insurer Approved

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

Lightweight Insulating Concrete Systems

ACFoam-II HCFC Free "Green" Polyiso Specification

Florida Department of Transportation

For 17 years, IRSI has been providing the CAT 5 Roof Design with Guaranteed Hurricane Protection

REPORT HOLDER: ATLAS EPS, A DIVISION OF ATLAS ROOFING CORPORATION 8240 BYRON CENTER SOUTHWEST BYRON CENTER, MICHIGAN EVALUATION SUBJECT:

TR26 LPC/FM / TR27 LPC/FM

LOW SLOPE ROOFING INSTALLATION

Hot Mopped / Cold Applied Adhered (VersiFleece AC TPO) Mechanically Attached Roofing System (VersiFleece AC TPO/VersiFleece AC EPDM)

2010 FLORIDA BUILDING CODE TEST PROTOCOLS HVHZ (TAS)

FM APPROVALS Boston Providence Turnpike, Norwood, MA Phone: (781) Fax: (781) E mail:

APPLICATION SAFETY TOOLS REQUIRED

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MODIFIED BITUMINOUS SHEET ROOFING REPORT HOLDER: CERTAINTEED CORPORATION

750ml INSTA-STIK roofing adhesive. Professional Roofing Adhesive

SBS Hot-Mopped & Cold Adhesive Roofing (COMGN289) Updated: 1/17

Firestone SBS Modified Bitumen Roofing System Design and Application Guide

COMMERCIAL WINDSTORM MITIGATION INSPECTION REPORT

FIRE-HALT SEALANT/SETTING COMPOUND

Moisture in Concrete Roof Decks and How to Evaluate its Effect on Roofing Systems

Duro-Last Roofing, Inc. 525 Morley Drive Saginaw, MI 48601

Good roofing practice has

1WHAT ARE THE ATTRIBUTES

SECTION CLAY BARREL TILE ROOFING. A. American Society for Testing and Materials (ASTM):

Product Technical Bulletin APS-5T

Privacy Policy Please visit for the CARE and GAF Privacy Policy.

DOCUMENT NUMBER: A ROOFING SYSTEM 4 APPLICATION: ELEMENTARY, MIDDLE AND HIGH SCHOOL DATE OF ISSUE:

GAF Commercial Roofing System Solutions Brochure Full Line Catalog

Thermoplastic Metal Retrofit Roofing System

SECTION MANUFACTURED ROOF EXPANSION JOINTS

YEARS SINCE Firestone UltraPly TM TPO Membranes EXPERIENCE THE ULTIMATE IN COOL ROOFING TECHNOLOGY.

SINTEF Building and Infrastructure confirms that. Protan G, GG og GT roofing and waterproofing membranes

ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION

The Role of Control Layers in Building Enclosure Design

MAKE ROOFS LAST LONGER

1. Decks, balconies, and sun porches 2. Walkways, ramps, and stairways 3. Patios and courtyards

ROXUL Roof and Deck Insulation Section Master Guide Specification Page 1 April 2016

Put OMG in your plans.

Commercial Roof Systems

ROOFING Sikalastic RoofPro SYSTEMS Liquid-Applied Membrane Technology

Transcription:

ROOF LISTINGS Foam-Control EPS is used in a wide range of UL Roof Listings, UL Roof Deck Constructions, and UL Hourly Designs. This document provides basic information on the use of Foam-Control EPS products and these applications. For complete and the most up to date information, please refer to the UL Online Certifications Directory. SINGLE PLY MEMBRANE SYSTEMS Class A - Fully Adhered Base Sheet: Soprema EPS FLAM STICK, self Cap Sheet: Soprema Sopralene Flam 180 FR+ Granular or Sopralene Flam 250 FR+ Granular, heat welded. Base Sheet: Soprema EPS FLAM STICK FR, self Cap Sheet: Soprema Sopralene Flam 180 FR+ Granular or Sopralene Flam 250 FR+ Granular, heat welded. Barrier Board: 1/4 in. (min) G-P Gypsum DensDeck or 1/2 in. (min) gypsum board with 6 in. offset to plywood joints. Base Sheet: EPS FLAM STICK, self Cap Sheet: Soprema Sopralene Flam 180 FR + Granular or Sopralene Flam 250 FR + Granular, heat welded. Base Sheet: Polyglass ELASATOFLEX SA V FR BASE, self Ply Sheet (Optional): Polyglass ELASATOFLEX SA V FR BASE, self Membrane: Polyglass ELASATOFLEX SA V FR, self Base Sheet: Polyglass ELASATOFLEX SA V FR BASE, self Ply Sheet (Optional): Polyglass ELASATOFLEX SA V FR BASE, self Membrane: Polyglass, ELASATOFLEX SA V FR, self Base Sheet: Polyglass ELASTOFLEX SA V FR BASE, self Ply Sheet (Optional): Polyglass ELASTOFLEX SA V FR BASE, self Membrane: Polyglass ELASTOFLEX VG FR, heat Base Sheet: Ridglass Manufacturing Roofgard HD self Ply Sheet (Optional): Ridglass Manufacturing Roofgard Base-Ply G self- Membrane: Ridglass Manufacturing Roofgard FR G self Insulation: Foam-Control EPS-ST, any thickness, any density, mechanically attached. Membrane: GAF Materials Corp. EverGuard Freedom TPO or GenFlex Roofing Systems GenFlex Peel & Stick TPO, max. 60 mil, self- Note: Information deemed reliable at time of printing. Please refer to the UL Online Certifications Directory for the latest information. June 2015.

Page 2 of 5 Class A, B or C - Fully Adhered Control Nailbase, any thickness, field covered with perlite 3/4 in. min thickness or 1/2 in. min USG Interiors Micore MC 180, Huebert wood fiber, Georgia-Pacific Sturdi-Top, Wood Fiber Industries Structodeck, Celotex wood fiber, thickness). Membrane: Any UL Classified modified bitumen system Note: Classification (A, B or C) will be the same as that for the original insulation/membrane roofing system. Max incline, attachment of membrane, and surfacing of membrane shall be in accordance with Classification established for Insulation: EPS/perlite or EPS/wood fiber (perlite 3/4 in. min thickness or 1/2 in. min USG Interiors Micore MC 180, Huebert wood fiber, Georgia-Pacific Corp. Strudi-Top, Wood Fiber Industries Structodeck, Celotex wood fiber, thickness), any combination, any thickness of the following: Foam-Control EPS, Foam-Control EPS Tapered, or Film Faced Foam-Control EPS, field covered with perlite or wood fiber, any thickness. Membrane: Any UL Classified EPDM, CPE, CSPE, PVE, CR, NBP or PIB membrane system suitable for use with any roof insulation. Note: Classification (A, B or C) will be the same as that for the original insulation/membrane roofing system. Maximum incline, attachment of membrane, and surfacing of membrane shall be in accordance with Classification established for Membrane: Any UL Classified modified bitumen system Note: Classification (A, B or C) will be the same as that for the original insulation/membrane roofing system. Max incline and surfacing shall be in accordance with the classification established for the insulation/membrane roofing system. Base sheet (if any) shall be in accordance with the classification established for the insulation/membrane roofing system. Membrane: Any UL Classified EPDM, CPE, CSPE, PVC, CR, NBP, TPO or PIB membrane system suitable for use with any roof insulation. Note: Classification (A, B or C) with be the same as that Class A - Mechanically Fastened Membrane: Any UL Classified CPE, CSPE, PVC, NBP, TPA, or EIP. Membrane: Any UL Classified TPO or PIB. Membrane: Any UL Classified EPDM. Membrane: HPG Roofing Systems SR 50, SR 60 or SR 80. Membrane: Seal-Dry/USA System 3000, 5000 or 7000 (PVC).

Page 3 of 5 Class A - Mechanically Fastened (cont.) Insulation: Foam-Control EPS, Foam-Control EPS Membrane: JPS Elastomerics Hi-Tuff (CSM). Membrane: Sarnafil S327 or G410. Membrane: Cooley C3 (TPA). Membrane: Duro-Last Duro-Last (PVC). Membrane: Bond Cote Roofing Systems Bond Cote. Insulation: Foam-Control EPS-ST, any thickness.. Membrane: Any UL Classified CPE, CSPE, PVC, NBP, TPA, or EIP. Insulation: Foam-Control EPS-ST, any thickness. Membrane: Carlisle Syntec Sure Weld TPO Membrane. Insulation: Foam-Control EPS-ST, any thickness. Membrane: Firestone FR-EPDM. Insulation: Foam-Control EPS-ST, any thickness and density, mechanically attached. Class B - Mechanically Fastened Tapered, or Film Faced Foam-Control EPS, min. 3/4 thick. Slip Sheet: Two layers of Elk VersaShield FB-1S. Membrane: Any UL Classified membrane. Class A, B or C - Mechanically Fastened Control Nailbase, any thickness, field covered with perlite 3/4 in. min thickness or 1/2 in. min USG Interiors Micore MC 180, Huebert wood fiber, Georgia-Pacific Sturdi-Top, Wood Fiber Industries Structodeck, Celotex wood fiber, thickness). Membrane: Any UL Classified single ply membrane system Note: Classification (A, B or C) will be the same as that Membrane: Any UL Classified single ply membrane system Note: Classification (A, B or C) will be the same as that Class A - Ballasted Control Nailbase, any thickness, field covered with 1/2 in. min perlite. Surfacing: River bottom stone (3/4 to 1-1/2 in. diam), 1000 lb/sq. Membrane: Any UL Classified PVC, CSPE or TPO, max. 60 mil.

Class A - Ballasted (cont.) Control Nailbase, any thickness. Surfacing: River bottom stone (3/4 to 1-1/2 in. diam), 1000 lb/sq. A.) Monolithic poured cementitious deck. B.) Steel covered with gypsum board or perlite board, 1/2 in. min. C.) Structural decks with all joints covered with Type 30 base sheet, extending 6 in. (min) on each side of joint. D.) Metal deck covered with cellular concrete, gypsum concrete, vermiculite concrete or perlite concrete. Control Nailbase, any thickness. Surfacing: River bottom stone (3/4 in. to 1-1/2 in. diam), 1000 lb/sq. Insulation: Foam-Control EPS-ST, any thickness, mechanically attached. Membrane: Any UL Classified membrane. Surfacing: River bottom stone (3/4 in. to 1-1/2 in. diam), 1000 lb/sq. Page 4 of 5 ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT Class A Control Nailbase, any thickness, field covered with 1/2 in. min perlite, 1/2 in. min wood fiber, or 1/4 in. min DensDeck.. Ply Sheet: Three to five plies Type 15, G1 or G2. Control Nailbase, any thickness, field covered with 3/4 in. min perlite. Ply Sheet: Three to five plies Type 15, G1 or G2. Insulation: Foam-Control EPS, Foam-Control EPS Control Nailbase, any thickness, field covered with 3/4 in. min perlite. Ply Sheet: Two or more plies Type 15, G1 or G2 (glass plies required with Type G3 cap sheet). MAINTENANCE AND REPAIR SYSTEMS Class A See UL Online Certifications Directory for current listings.

UL ROOF DECK CONSTRUCTIONS. Page 5 of 5 Foam-Control EPS is suitable for use in the following UL Roof Deck Constructions. No. 76 No. 100 No. 155 No. 219 No. 237 No. 292 No. 319 No. 342 No. 342A No. 374 No. 419 No. 427 No. 458 No. 486 No. 487 No. 581 No. 631 No. 645 No. 666 No. 667 No. 681 No. 683 No. 687 UL HOURLY DESIGNS. Foam-Control EPS is suitable for use in the following hourly designs. D303 D755 D759 D775 D795 D902 D916 D922 D923 D927 D929 D949 D957 D958 D975 P225 P230 P231 P235 P238 P246 P250 P251 P254 P255 P259 P261 P264 P269 P302 P404 P410 P411 P503 P508 P509 P510 P511 P513 P514 P515 P519 P520 P521 P525 P527 P535 P540 P541 P542 P543 P546 P550 P551 P553 P562 P563 P564 P678 P701 P710 P713 P717 P719 P725 P731 P732 P734 P735 P739 P741 P742 P749 P751 P825 P828 P840 P902 P904 P905 P907 P909 P910 P912 P913 P915 P916 P919 P920 P921 P922 P923 P925 P926 P928 P929 P930 P936 P939 P940 P942 P943 P944 P945 P947 Foam-Control EPS products are manufactured by AFM Corporation licensees. Copyright 2015 AFM Corporation. All rights reserved. Printed in USA. Foam-Control and Control, Not Compromise are registered trademarks of AFM Corporation, Lakeville, MN. UL logo is a registered trademark of UL LLC. R10-10/15 CONTROL, NOT COMPROMISE.