The exam is enclosed with this correspondence. This test emphasizes standard requirements for installing gravity-fed septic systems.

Similar documents
INSTRUCTIONS FOR SUBMITTING A COMMERCIAL SEWAGE DISPOSAL PERMIT APPLICATION

GRAY WATER SYSTEMS (Reference California Plumbing Code Chapter 16 and 16A) Revised: 6/11/14

GRAY WATER RECYCLING SYSTEMS

GRAY WATER SYSTEMS FOR RESIDENTIAL BUILDINGS

GUIDELINES FOR INSTALLATION OF ON-SITE SEWAGE SYSTEMS

GUIDELINES FOR SEPTIC SYSTEM DESIGN

Last Updated March 15, 2016

West Virginia Department of Health & Human Resources Department of Health

Enviro-Septic Wastewater Treatment System Indiana Design and Installation Manual for Residential Systems

Commonwealth of Pennsylvania Department of Environmental Protection (DEP) Bureau of Water Standards and Facility Regulation Harrisburg, PA

System Design & Installation Manual

SECTION TRENCHING & BACKFILLING

Commonwealth of Massachusetts Title 5 Official Inspection Form Subsurface Sewage Disposal System Form - Not for Voluntary Assessments

Figure 1. Report of Inspection Process Flowchart.

Geotextile Sand Filter

In preparation for constructing buildings on a property, the builder. Site Preparation CHAPTER

MONROE COUNTY ZONING OFFICE

Reclaimed Water Treatment, Distribution, Pumping and Storage Engineering Report Form

SEPTIC TANK CONSTRUCTION GUIDELINES

Living With a Septic System A homeowner s guide to basic septic system operation and maintenance

NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF ENVIRONMENTAL HEALTH ON-SITE WASTEWATER SECTION

Education on Common Household Sewage Treatment Systems Found In Allen County, OH

INSTALLING A SEPTIC SYSTEM IN LIVINGSTON COUNTY LIVINGSTON COUNTY PUBLIC HEALTH DEPARTMENT 310 TORRANCE AVENUE PONTIAC, IL /

SEWAGE DISPOSAL SYSTEMS

FLOWTECH WASTEWATER TRENCH SYSTEMS Manufactured with 100% Recycled Artificial Aggregate

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 5/8/7)

SECTION AGGREGATES

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter X X X Adopt Entire Chapter as amended (amended sections listed below) X X X X X X

Soil and Site Evaluation for OSS

SECTION 820 PUMP STATION DEMOLITION AND SITE RESTORATION

TABLE 1 OAR MINIMUM SEPARATION DISTANCES

1 Exam Prep Chapter 64E -6 Questions and Answers

Contact the Jurisdictional Engineer for materials allowed by each jurisdiction.

STORMWATER AND EROSION CONTROL PERMIT

Geotextile Sand Filter

Sanitary Sewer Extensions, Lift Stations, and Force Mains Engineering Report Form. I. General Information. 1. Name of Facility:

SEWAGE PERMIT APPLICATION

APPENDIX K PRIVATE SEWAGE DISPOSAL SYSTEMS

Webinar: Understanding the California Plumbing Code for Greywater (Gray water) Installations

RESIDENTIAL CONSTRUCTION New Dwellings and Additions

HOLDING TANK PLANNING & INSTALLATION GUIDELINES

Red Fox Run Property Owner s Association, Inc. P.O. Box 194 Tryon, NC 28782

TOWNSHIP OF LOGAN 125 MAIN STREET, PO BOX 314 BRIDGEPORT, NJ FAX

Application for a Sewage System Permit

Commonwealth of Pennsylvania Department of Environmental Protection (DEP) Bureau of Point and Non-Point Source Management Harrisburg, PA

Application for a Sewage System Permit

SEWAGE TREATMENT SYSTEM RULES February 1, 2015

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS

SUBSURFACE INFILTRATION SYSTEM DESCRIPTION. Alternative Names: Sump, Drywell, Infiltration Trench, Infiltration Galleries, Leach Fields

SEWER SYSTEM DESIGN GUIDELINES

StormwaterWise Landscapes: Pervious Surfaces Specifications

TOILET FACILITIES AND SEWAGE DISPOSAL REGULATIONS

Rural Servicing Guidelines

Advanced Enviro-Septic TM Basic Design and Installation Manual

C. Foundation stabilization for pipe and utility structures.

The following is required for a complete permit submittal for each unit.

Geotextile Sand Filter

Design and Installation Manual for the Infiltrator ATL System in British Columbia

BIG O HDPE TUBING HDPE CORRUGATED TUBING FOR AGRICULTURAL, RESIDENTIAL AND HIGHWAY DRAINAGE INCREASE CROP YIELDS LOWER PRODUCTION COSTS

Section 8: Amended Soil Mounds. 8. Amended Soil Mounds

ALLEGAN COUNTY WATER AND SEWAGE REGULATIONS PURPOSE

On-Site Sewage Disposal Systems. Santa Barbara County Environmental Health Services

LAWS AND RULES FOR SEWAGE TREATMENT, AND DISPOSAL SYSTEMS

At least 2 feet above the seasonal high water table Overflow path or structure provided

On-Site Leaching Chamber Specifications & Features. Design & Installation Manual Ohio

2016 CALGREEN RESIDENTIAL CHECKLIST MANDATORY ITEMS City of San Carlos - Building Division 600 Elm Street, San Carlos, CA Phone:

Design and Construction Manual for Sand Mound Systems

Geotextile Sand Filter

Construction Application for Permit (CAP) Instructions

PERMEABLE INTERLOCKING PAVERS

BUILDING CODES & DESIGN CRITERIA

CHAPTER 8 EROSION AND SEDIMENT CONTROL PLAN REQUIREMENTS

recycle water reuse it save up to from showers & baths for flushing toilets 30% of water use

LANDSCAPE RETAINING WALLS

Read Only Copy Not For Distribution. Chapter 17. Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.2 QUANTITY OF WATER REQUIRED

OWNER S, OPERATIONAL, AND MAINTENANCE MANUAL

SECTION FACILITY SANITARY SEWERS

CITY OF CAMDENTON OFFICE OF THE BUILDING OFFICIAL Commercial Building & Architectural Review Permit Application

Redi Rock Specification and Installation Manual

WARWICK TOWNSHIP Dept. of Planning & Zoning

Inspection Report. 1 of 8

File No Supplemental November Geotechnical and Environmental Consulting Engineers

TOWN OF ROTTERDAM RESIDENTIAL BUILDING PERMIT APPLICATION Ext. 395 Needed to Obtain Permit:

Received by:* Date Received:* Zoning Approval:* Date:* PERMIT#:* *ZONING: *SETBACKS: FRONT ft/ SIDE ft/ REAR ft *FLOOD ZONE:

CITY OF ASTORIA PUBLIC WORKS ENGINEERING DIVISION ENGINEERING DESIGN STANDARDS FOR IN-FILL DEVELOPMENT

NEW CASTLE CONSERVATION DISTRICT. through. (Name of Municipality) PLAN REVIEW APPLICATION DRAINAGE, STORMWATER MANAGEMENT, EROSION & SEDIMENT CONTROL

BUILDING PERMIT APPLICATION

SECTION FOUNDATION DRAINAGE

GUIDELINES FOR SUBMISSION OF AN APPLICATION FOR A SEWAGE SYSTEM PERMIT

SECTION 19 - TRENCH EXCAVATION, BEDDING AND BACKFILL TABLE OF CONTENTS

SECTION 19 - TRENCH EXCAVATION, BEDDING AND BACKFILL TABLE OF CONTENTS

Advanced Enviro-Septic Systems Design and Installation Manual

City of Charlotte BMP Maintenance and Inspection Check List Grassed Channels / Swales [Note: a separate form must be used for each BMP]

Product Registration Renewal #2 Notice of Proprietary Distribution Product Listing

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

Alternate Systems Guidance

NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF ENVIRONMENTAL HEALTH ON-SITE WASTEWATER SECTION

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter Adopt Entire Chapter as amended (amended sections listed below)

On-site wastewater treatment systems

Transcription:

Harrison County Health Department Environmental Health Division 241 Atwood Street, Suite 200 Corydon, Indiana 47112 Phone (812) 738-3237 Fax (812) 738-4292 www. HarrisonCountyHealth.com To: Septic Installers From: Harrison County Health Department Re: Septic Installer Certification Septic system installers must demonstrate competency in knowledge of county and state codes before installing septic systems. General knowledge of septic system installation will be tested through an exam developed and administered by the health department. The exam is enclosed with this correspondence. This test emphasizes standard requirements for installing gravity-fed septic systems. Please complete the exam by using State Rule 410 IAC 6-8.2 as an information source. The answers will be found in that publication. It is available as a PDF online at www.in.gov/isdh/files/410_iac_6-8_2_w_changes_hilighted.pdf. To obtain certification, you must achieve a score of at least 80% correct. If you are unable to complete this requirement, you/your company must set up an appointment with one of the staff members and review the test. Once you have completed the review to the satisfaction of the health department, we will process your application and issue your certification. In order to obtain certification and install septic systems in Harrison County, our office must receive: 1) A completed application (attached), 2) Either: A Harrison County Health Department septic installer s test score of no less than 80%, or proper review of the test questions at this department, OR A copy of your IOWPA certification The Health Department makes a list of Harrison County approved septic system installers available to the public. If you wish to appear on that list, you must: 1) Have scored satisfactorily on the Harrison County Health Department installers exam OR be IOWPA certified, and 2) Have installed at least three (3) septic systems correctly to state and county codes. If you have any questions on this matter, please call our office. Good luck! Danny R. Schroeder Chris Cunningham Tracy Monroe EHS EHS EHS Harrison County Health Department Septic Installer s Exam Page 1 of 10

Harrison County Health Department 241 Atwood Street, Suite 200 Corydon, Indiana 47112 Phone (812) 738-3237 Fax (812) 7384292 Application for Septic System Installer Certification If requested, the information you provide on this application will be made available to the public. The Health Department may furnish, to the public, a list of Harrison County Health Department approved septic system installers, their name or company name, address, and phone number. To be permitted to install septic systems within Harrison County, please complete this application and return it to the Health Department. Business Name Owner's Name Address City State Zip Phone Cell Phone Fax E-mail address Name and Title of Applicant Signature of Applicant Do you wish to appear on the Installer's List? Yes No (You must first pass a Harrison County Health Department or IOWPA septic installer s exam AND properly install at least 3 septic systems in Harrison County to State and County codes) It is encouraged that all septic installers, helpers, etc. on a job site be certified, but a minimum of one certified person is required to be available at all times during septic system installation. If there are significant changes in the State septic system codes, re-examination may be necessary. For Health Department use only Date issued Permit # Score % Harrison County Health Department Septic Installer s Exam Page 2 of 10

Harrison County Health Department SEPTIC INSTALLER S EXAM General knowledge of subsurface gravity flow septic systems MULTIPLE CHOICE. CHOOSE THE ONE BEST ANSWER. 1. When may you install a septic system before obtaining a septic permit from the health department? a) When rain is imminent b) When the owner insists c) When you are pressed for time d) When you hear thunder in the distance e) Never 2. After obtaining a septic permit, circumstances change; i.e. the owner decides to move the house or now wants four bedrooms instead of three. What do you do? a) Change your installation plans to accommodate the owner and go ahead b) Contact the health department c) Tell the owner there can be no changes d) Tell the owner your fee has just increased e) Sub-contract the job to another installer 3. What is the minimum distance a septic tank can be from a dwelling, an in-ground pool, or other structure? a) 5 feet b) 7.5 feet c) 10 feet d) 15 feet e) 20 feet 4. What is the minimum distance any part of the septic system may be from the property line? a) 3 feet b) 5 feet c) 7.5 feet d) 10 feet e) 20 feet 5. What 4 solid pipe is accepted in Harrison County for gravity septic systems? a) ASTM D 3034 b) ASTM D 2729 c) ASTM F 810 d) ASTM D 2661 e) ASTM C 4-62 6. What 4 perforated pipe is accepted in Harrison County for Gravity septic systems? a) ASTM D 3034 b) ASTM D 2729 c) ASTM D 2661 d) ASTM F 810 e) Both b and d Harrison County Health Department Septic Installer s Exam Page 3 of 10

7. What is the minimum allowable distance from the center of one absorption trench to the center of the adjacent absorption trench? a) 5 feet b) 7.5 feet c) 10 feet d) 12.5 feet e) 15 feet 8. What is the maximum allowable length of any one absorption trench? a) 100 feet b) 120 feet c) 125 feet d) 150 feet e) 200 feet 9. What is the only type of stone approved in Harrison County for use in the lateral lines? a) #9 (3/4 to 1 ) crushed limestone b) #11 (1/2 ) crushed limestone c) 5L (3/4 to 2-1/2 ) washed river gravel d) pea (<1/2 ) river gravel e) rip rap 10. What material(s) is/are approved as a covering for the aggregate in the absorption trenches? a) Tar paper b) Straw c) geotextile fabric d) Recycled chopped tires e) Hardwood mulch 11. According to Indiana Code, what is the maximum allowable drop from the beginning of the absorption trench to the end? a) 0 b) 2 c) 4 d) 6 e) 12 12. A minimum of how many inches of gravel are required above and below the perforated pipe in the absorption trench? a) 3 below and 3 above b) 4 below and 2 above c) 4 below and 4 above d) 6 below and 2 above e) 6 below and 4 above 13. What is the minimum soil cover required over the gravel in the absorption trench? a) 6 b) 9 c) 10 d) 12 e) 18 Harrison County Health Department Septic Installer s Exam Page 4 of 10

14. On new construction what are the minimum and maximum allowable depths for a gravity absorption trench? a) Minimum 6, maximum 18 b) Minimum 8, maximum 24 c) Minimum 10, maximum 36 d) Minimum 18, maximum 48 e) Minimum 24, maximum 60 15. A site is unsuitable for a subsurface septic system if the ground slope is more than %. a) 5% b) 10% c) 15% d) 20% e) 25% 16. The required fall for 25 feet of 4 solid pipe running from the home to the septic tank is. a) Minimum 2, maximum 24 b) Minimum 3, maximum 30 c) Minimum 4, maximum 36 d) Minimum 6, maximum 48 e) Minimum 8, maximum 48 17. From the distribution box to any perforated pipe, the minimum separation distance is: a) 2 feet b) 3 feet c) 5 feet d) 7.5 feet e) 10 feet 18. The minimum distance a perimeter (curtain) drain may be from any part of the soil absorption trench. a) 5 feet b) 7.5 feet c) 10 feet d) 15 feet e) 20 feet 19. On a sloping site, absorption trenches of a gravity-fed soil septic system shall be constructed: a) However and wherever you choose b) Running down the hill c) In a circular pattern d) Along the contour e) Running up the hill toward the home 20. In a flood dosed (pump assisted) septic system, what is the discharge rate in gallons per minute (gpm) for a 3-bedroom home? a) 10-12 gpm b) 20-25 gpm c) 30-45 gpm d) 50-60 gpm e) 60-75 gpm Harrison County Health Department Septic Installer s Exam Page 5 of 10

21. On new construction, what are the minimum and maximum allowable depths for a flood dose absorption trench? a) Minimum 6, maximum 18 b) Minimum 8, maximum 24 c) Minimum 10, maximum 36 d) Minimum 18, maximum 48 e) Minimum 24, maximum 60 22. A jetted bathtub is treated as a bedroom equivalent for septic system sizing requirements if its capacity is greater than: a) 75 gallons b) 100 gallons c) 110 gallons d) 125 gallons e) 150 gallons 23. If a perimeter drain is required, how much deeper than the adjacent trench bottom must it be? a) 10 inches b) 12 inches c) 18 inches d) 24 inches e) 36 inches 24. Excessive of the trench sidewalls or bottom during construction may result in irreversible damage to the infiltrative surface and may be grounds for rejection of the system. a) tearing b) smearing c) loading d) turning e) ripping 25. The best reason for not installing a septic system during periods of wet weather when the ground is muddy is: a) Your equipment will sink in the mud and you may not be able to finish the system. b) The septic tank might float. c) Your wife will kill you when you track mud into the house. d) Severe compaction can occur on the site as heavy equipment is moved about. e) Smearing of the trench sidewalls and bottom can damage those surfaces so water cannot infiltrate the soil. f) Both a) and b) g) Both d) and e) 26. Perimeter drains that outlet to the surface require: a) Vents b) Rodent guards c) Cleanouts d) Caps so water discharge is prevented e) Mosquito larvacides Harrison County Health Department Septic Installer s Exam Page 6 of 10

27. Which of these situations requires that a residential sewage disposal system be pumpassisted? a) The system is being installed in a floodplain. b) No aggregate is available. c) The total lineal footage of the absorption field exceeds 330 feet. d) The total lineal footage of the absorption field exceeds 500 feet. 28. What is the minimum allowable distance from any part of the absorption field to: a) A private well b) Water lines under pressure c) A pond, lake or reservoir d) A stream or ditch e) Dwelling, in-ground pool, or structures (upslope side) f) Dwelling, in-ground pool, or structures (downslope side) min, max 29. Perforated, corrugated pipe may be used as lateral lines. 30. Distribution boxes are designed to split the effluent equally among the effluent ports. Therefore the outlets must be at the same elevation. 31. The bottom of an absorption trench shall not be installed below the elevation of the 100-year flood plain. 32. Excessive smearing of the bottom and side walls of the absorption trenches is grounds for rejection of the system and/or the site. 33. A septic tank that meets all requirements but is constructed of a plastic material is permitted. 34. Cleanout risers (access manholes) attached to the tank or pump chamber must be made of concrete. 35. After the septic permit is issued, it may be voided by the Health Department if the site is disturbed or altered by the unauthorized addition of fill material, by cutting, scraping, compaction, or removal of soil. Harrison County Health Department Septic Installer s Exam Page 7 of 10

36. Which one of the following is an indicator of a septic system failure? a) The system accepts sewage and all plumbing fixtures work properly. b) Effluent is ponding on the surface of the ground. c) The most-used toilet runs constantly. d) The kitchen drain emits a foul odor. e) The kitchen sink gurgles when the dishwasher is in operation. 37. State septic code prohibits water from the washing machine from entering the septic tank. 38. Before a septic permit can be issued, in addition to a soils evaluation and site survey application, the location of all property lines, buildings, outbuildings, pools, driveways, tanks and lateral lines must be flagged out: a) to ensure the septic system will fit on the lot within the required setbacks. b) so as to avoid all drainage ways by at least 200 feet. 39. ESSAY QUESTION - How can you tell if it is too wet to install a subsurface septic system? The plastic limit of the soil is considered to be exceeded when.. Harrison County Health Department Septic Installer s Exam Page 8 of 10

40. Is the slope in this example too steep to install a subsurface gravity feed septic system? Horizontal Run (R) = 30 feet = 360 inches Vertical Distance (D) = 62 inches HINT: D R = % SLOPE Figure the percent slope here. Please show your work. 41. In new construction, the definition of a bedroom is: A room of 70 square feet or more with at least one closet, and having one operable window or exterior door for egress. 42. Your local health department may NOT be more stringent than the Indiana State Septic Code. 43. As of January 1, 2011, concrete distribution boxes are NO LONGER allowed. 44. A septic tank MAY be installed in a 100-year flood plain if the riser is installed above the 100-year flood elevation. 45. If the septic system requires a perimeter drain, it must be covered with geocloth prior to backfilling to prevent the aggregate from becoming clogged with soil/backfill. 46. Patios without footers, above-ground swimming pools, and sidewalks MAY BE located within 10 feet of the septic tank as long as no required access points are obstructed. Harrison County Health Department Septic Installer s Exam Page 9 of 10

47. Residential sewer pipe (from the home to the tank) may have a vertical drop of up to 36 only if a cleanout is located immediately upslope. 48. According to 410 IAC 6-8.2, what is the frost depth in Harrison County? a) 12 b) 24 c) 30 d) 36 e) 40 49. Abandoned septic tanks must be backfilled with: a) debris-free sand or other granular material, concrete, or soil b) stumps c) construction debris d) old tires e) concrete and mean old mothers-in-law 50. An outlet filter shall be installed in the septic tank of: a) new on-site systems b) existing systems that are undersized c) existing systems with lateral field failure Harrison County Health Department Septic Installer s Exam Page 10 of 10