Evaluation Listing CCMC L Icynene ProSeal (MD-C-200v3)

Similar documents
Evaluation Listing CCMC L Boreal Lavender and Boreal Nature

Mineral-Fibre Thermal Insulation for Buildings

Evaluation Listing CCMC L Nordic X-Lam

Evaluation Report CCMC R Trex Transcend Decking

Power JoIst ADI-40, ADI-60, ADI-80 I-joists

Evaluation Report CCMC R LP SolidStart LVL

Product Information Bulletin

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

ISO INTERNATIONAL STANDARD. Rigid cellular plastics Spray-applied polyurethane foam for thermal insulation Part 3: Test methods

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

ESR-1826 Reissued February 1, 2013 This report is subject to renewal February 1, 2015.

Short Form Guide Specification. STYROFOAM CAVITYMATE Ultra Air Barrier Wall System

May 19, 2006 Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: NATURAL POLYMERS, LLC

MASTERFORMAT SPECIFICATION

Clarifying the Fenestration Energy Performance requirement in the Ontario Building Code Supplementary Standard SB12

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: RHINO LININGS CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: BASF CORPORATION (RIGID PU SYSTEMS)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

Wall Insulation: Selection, Application and Specification

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) LLC

EXPANDED POLYSTYRENE (EPS GEOFOAM) EMBANKMENT DIVISION 31 EARTHWORK

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: THE SPRAY MARKET, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

Phenolic foam thermal insulation products for buildings and building services end use applications

SYNTHOS XPS PRIME G1 SYNTHOS XPS PRIME G2

The Participants in this GreenON Rebates Program are homeowners and landlords.

WALL APPLICATIONS IN BUILDINGS EXCEPTIONAL R-VALUE. OUTSTANDING RESISTANCE TO MOISTURE. LONG TERM DURABILITY.

SPECIFICATION RW-2514 Document Number NBC MARKER SYSTEM (Ladder Form) NBC-SCE

AS/NZS :2014. Guide to the protection of structural steel against atmospheric corrosion by the use of protective coatings AS/NZS 2312.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

Trusted DIVISION: 07 SYSTEM. Conformity! ICC-ES Evaluation. not specifically. Copyright 2014

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

In 2000, a new, prescriptive test method (CAN/ULC-S770, Standard Test

ISO 4898 INTERNATIONAL STANDARD. Rigid cellular plastics Thermal insulation products for buildings Specifications

SUBMITTAL FORM All GreenFiber Products Date: Submitted to: Submitted by: Job Reference: Job Name: GREENFIBER PRODUCT ATTRIBUTES

Australian Standard. Cement mortar lining of steel pipes and fittings AS AS 1281

ANSI/APA PRS Standard for Performance-Rated Structural Insulated Panels in Wall Applications

ACFoam-II HCFC Free "Green" Polyiso Specification

DIVISION: THERMAL AND MOISTURE SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CHEMICAL BROTHERS INTERNATIONAL, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

SECTION and/or Resilient Sheet Flooring and/or Resilient Tile Flooring

INTERNATIONAL STANDARD

ANSI/APA PRS Standard for Performance-Rated Structural Insulated Panels in Wall Applications

Date of Authorization June 29, 2006 BMEC Authorization Authorization Report - Camino Modular Floor System: SC Series

Spray Polyurethane Foam. Insulation and Air Barrier Requirements of the 2012 I-Codes. Spray Foam Coalition

Originally Issued: 03/21/2014 Revised: 04/12/2018 Valid Through: 03/31/2019

FOR FURTHER INFORMATION ON THE KOOLTHERM RANGE OF PRODUCTS PLEASE TELEPHONE THE KINGSPAN TECHNICAL SERVICES DEPARTMENT (01457)

AS/NZS 2280:2012 AS/NZS

Everlast Basic Rolls and Tiles GUIDE SPECIFICATIONS Ecore

V1/0715/AI/TDO1. KORE Loft. Insulated Flooring System Design Guide

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: TERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

ICYNENE AND. CaGBC LEED Credit Opportunities For

ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

THE FOAMULAR HIGH DENSITY

Phono Spray S-907 system does not contain ozone depleting blowing agents (CFC and HCFC).

BUILDING PERMIT GUIDELINES - RESIDENTIAL

Residential Product Selector Guide

Rigid Polyurethane Insulation

2013 COMMERCIAL PRODUCTS

BRE Global Test Report

Phono Spray I-905 system does not contain Ozone Depleting Potential blowing agents.

SECTION PERMANENT FORMS - INSULATING CONCRETE FORMS Page 1 of 7

Evaluation Report CCMC R. 1. Opinion

Spray Polyurethane Foam: The Need for Vapor Retarders in Above-Grade Residential Walls

WoodTrends Acoustical Wood Ceiling System BASIC Specification

Tehnical Data Sheet Astro Intu Mastic. UIC of product-type: INTUM CPR-JA5015

INTERNATIONAL STANDARD

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: BASF CORPORATION

Vapour Diffusion for Residential Construction. Canada and Northern USA VAPOUR DIFFUSION FOR RESIDENTIAL CONSTRUCTION CANADA AND NORTHERN USA

PinkWood Ltd. Revised September 29, 2017

Graphite Polystyrene (GPS) Rigid Insulation. High Performance Thermal Innovation

INFINITY MAX TILE SPECIFICATION

Application Specification:

ICEA STANDARD FOR DISTRIBUTION FRAME-WIRE TECHNICAL REQUIREMENTS. Published By INSULATED CABLE ENGINEERS ASSOCIATION, INC. Post Office Box 1568

Österreichisches Institut für Bautechnik Schenkenstrasse Vienna Austria T F

SECTION G RELIEF VENTS A-0

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS

Evaluation Report. for. Empire West, Inc Graton Road Post Office Box 511 Graton, California 95444

ISO INTERNATIONAL STANDARD. Rigid cellular plastics Spray-applied polyurethane foam for thermal insulation Part 2: Application

ESR-1655 Reissued April 2014 This report is subject to renewal April 1, 2016.

(Specifier Note: Aristech Surfaces LLC is the manufacturer of the Avonite brand

Improve Energy Efficiency and Moisture Performance of Foundations

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

Foam Vs Fiber. Air Sealing Benefit of Foam in Single Family Residential New Construction. Gary Parsons Fellow, Dow Building Solutions R&D

Australian Standard. Qualification of welders for fusion welding of steels AS AS

Regupol AktivPro RESILIENT ATHLETIC SURFACING REGUPOL RECYCLED RUBBER MOLDED TILES

PERFORMANCE OF SIDE-BY-SIDE SOUTH TEXAS HOMES Isolating the Contribution of Spray Polyurethane Foam Insulation

EasylationWall. External Wall Insulation System. bringing european innovation

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

CCMC MgO Board Advisory

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

Canada's National Model Construction Codes Development System

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0

Transcription:

CONSTRUCTION Evaluation Listing CCMC 13683-L Icynene ProSeal (MD-C-200v3) Evaluation Issued: 2014-04-16 Re-evaluation due: 2017-04-16 Preface: Masterformat 07 21 19.02, Spray-Applied Rigid Polyurethane Foam Insulation, Medium Density Preface Issued: 2014-04-11 Scope These Evaluation Listings apply to spray-applied rigid polyurethane foam, medium density, intended for use as thermal insulation for both building and non-building applications, whether applied on a building site or in a prefabrication (manufacturing) process. This material is also known as foamed in-situ insulation. The continuous-use temperature is within the range of 60 C to +80 C. The proponent has demonstrated that the product meets the following standard (see Table 1 for the performance requirements): CAN/ULC-S705.1-01 (with Amendments No. 1 and 2), Standard for Thermal Insulation Spray Applied Rigid Polyurethane Foam, Medium Density Material Specification ; or CAN/ULC-S705.1-01 (with Amendments No. 1, 2 and 3), Standard for Thermal Insulation Spray Applied Rigid Polyurethane Foam, Medium Density Material Specification. Spray-applied rigid polyurethane foam, medium density, shall be installed by a licensed installer in accordance with the manufacturer s instructions and the following standard: CAN/ULC-S705.2-05, Standard for Thermal Insulation Spray Applied Rigid Polyurethane Foam, Medium Density Application. For compliance to CAN/ULC-S705.2, users should contact the third-party organization that has been identified by the foam manufacturer as the third party operating the field quality assurance program (FQAP) for the foam product (see product listing). 1 of 5

Standard Table 1. Performance Requirements for Physical Properties Property Unit Minimum Requirement Maximum Air permeance (mandatory material testing) L/s @ 75 Pa No min. 0.02 Air permeance (optional system testing) L/s @ 75 Pa No min. 0.05 Apparent core density kg/m 3 28 No max. Compressive strength kpa 170 No max. 20 C % No min. 1 Dimensional stability volume change at 80 C % 1 8 70 C, 97 ± 3% RH % No min. 14 Surface-burning characteristics - flame spread No min. 500 1 Open-cell content volume % No min. 8 Initial thermal resistance of a 50-mm-thick specimen after 3 days at 23 ± 2 C m 2 C/W Declare No max. Conditioned thermal resistance of a 50-mm-thick specimen after 180 days at 23 ± 2 C 90 days at 60 ± 2 C m 2 C/W Declare 2 No max. Long-term thermal resistance (LTTR) of a 50-mm-thick specimen Type 1 m 2 C/W 1.8 No max. LTTR of a 50-mm-thick specimen Type 2 m 2 C/W 2.0 No max. Tensile strength kpa 200 No max. Volatile organic emissions Pass 3 No max. Water absorption by volume % No min. 4 Water vapour permeance of a 50-mm-thick specimen ng/(pa s m 2 ) No min. 60 Notes to Table 1: 1 2 Results are valid for qualification to the standard. As noted in the standard, for building code purposes, the flame-spread rating shall be conducted in accordance with the code-specified flame-spread test details with respect to the number of specimens to be tested, specimens tested intact and cut specimens. This requirement is only referenced in CAN/ULC-S705.1-01 (with Amendments No. 1 and 2). 2 of 5

3 Pass means that after 30 days the volatile organic compound emissions do not exceed the maximum indoor air concentration stated in Table 2 of CAN/ULC-S705.1. In cases of retrofit construction (e.g., occupied buildings), CAN/ULC-S705.2 requires that the ventilation rate be no less than 0.3 air changes per hour within the working area during the application of the product and that the working area be isolated during spraying. The same ventilation rate is required after the product has been sprayed and for the time period determined in accordance with CAN/ULC-S705.1. See the product listing for the time period required before occupancy. Labelling In compliance with CAN/ULC-S705.1-01 (with Amendments No. 1 and 2), each liquid component container shall be identified as either the polyisocyanate component ( A ) or the resin component ( B ). Unless otherwise specified, each container shall be marked with the following information: lot number; date of manufacture; use before date; the means to identify the installed product; and conformance with CAN/ULC-S705.1. In compliance with CAN/ULC-S705.1-01 (with Amendments No. 1, 2 and 3), each liquid component container shall be identified as either the polymeric isocyanate component ( A ) or the resin component ( B ). The polymeric isocyanate component shall be marked with the following information: lot number; and date of manufacture. The resin component shall be marked with the following information: lot number; date of manufacture; use before date; the means to identify the installed product; CAN/ULC-S705.1 ; and LTTR (50 mm) RSI result. National Building Code of Canada (NBC) NBC References CAN/ULC-S705.1-01 is referenced in Table 5.10.1.1. and Clause 9.25.2.2.(1)(g) of Division B of the NBC 2010. CAN/ULC-S705.2-05 is referenced in Sentences 5.3.1.3.(3) and 9.25.2.5.(1) and Table 5.10.1.1. of Division B of the NBC 2010. 3 of 5

Evaluation Listing CCMC 13683-L: Icynene ProSeal (MD-C-200v3) Evaluation Issued: 2014-04-16 Re-evaluation due: 2017-04-16 1. Evaluation This product conforms to CAN/ULC-S705.1-01 (with Amendments No. 1, 2 and 3), Type 2. For retrofit constructions, time before occupancy is one (1 day). The LTTR for 50 mm is RSI 2.02. 2. Description The product is a Type 2, spray-applied rigid polyurethane foam of medium density. The foam system consists of two components: Icynene Base Seal isocyanate and a polyurethane resin identified as Icynene ProSeal (MD-C-200v3). The two components are mixed on-site by a qualified installer with fixed-ratio positive displacement equipment. The colour of the final cured product is platinum. 3. Standard and Regulatory Information Morrison Hershfield (MH) has been identified by Icynene Inc. as the third-party organization that operates the FQAP for the product in accordance with CAN/ULC-S705.2-05. MH can be contacted at 800-796-5792. See the Preface and the standard for explanation. Listing Holder Icynene Inc. 6747 Campobello Road Mississauga, ON L5N 2L7 Telephone: 905-363-4040 Fax: 905-363-0102 Plant(s) Mississauga, ON Disclaimer This Listing is issued by the Canadian Construction Materials Centre, a program of NRC Construction at the National Research Council of Canada. The Listing must be read in the context of the entire CCMC Registry of Product Evaluations. Readers must confirm that the Listing is current and has not been withdrawn or superseded by a later issue. Please refer to http://www.nrc-cnrc.gc.ca/eng/solutions/ advisory/ccmc_index.html, or contact the Canadian Construction Materials Centre, NRC Construction, National Research Council of Canada, 1200 Montreal Road, Ottawa, Ontario, K1A 0R6. Telephone (613) 993-6189. Fax (613) 952-0268. 4 of 5

NRC has evaluated the material, product, system or service described herein only for those characteristics stated herein. The information and opinions in this Listing are directed to those who have the appropriate degree of experience to use and apply its contents. This Listing is provided without representation, warranty, or guarantee of any kind, expressed, or implied, and the National Research Council of Canada (NRC) provides no endorsement for any evaluated material, product, system or service described herein. NRC accepts no responsibility whatsoever arising in any way from any and all use and reliance on the information contained in this Listing. NRC is not undertaking to render professional or other services on behalf of any person or entity nor to perform any duty owed by any person or entity to another person or entity. Date modified: 2014-04-17 5 of 5