HYDROMATIC SKV50 SEWAGE EJECTOR PERFORMANCE DATA SKV50. Wholesale Products Page: RPM: 1650 Discharge: 2 Solids: 2.

Similar documents
HYDROMATIC W/D/V-A1 SUBMERSIBLE SUMP/EFFLUENT

HUP. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 1" Solids: 1/8" GPM: TDH:

SK75/100. Performance Data TOTAL HEAD IN FEET HEAD-METERS 6 SK100 SK Liters/Second Capacity-U.S. G.P.M.

SECTION SLUDGE HOLDING TANK DECANTER PUMP

Series Sump and Sewage Systems

FAIRBANKS NIJHUIS SUBMERSIBLE SOLIDS HANDLING PUMPS.

SECTION PACKAGE BOOSTER PUMP STATIONS

BEST ONE SUBMERSIBLE SUMP PUMPS EPA. Page Features & Applications 100 Exploded View 101 Pump & Motor Specifications 102 Selection Chart / Type key 103

SUGGESTED SPECIFICATIONS

W ARR A NTY FAIRBANKS NIJHUIS 1600 SERIES SINGLE STAGE END SUCTION PUMPS. Certified to NSF/ANSI 372.

SUGGESTED SPECIFICATIONS Pump Frames through 64132

C. ASSE 1013 Performance Requirements for Reduced Pressure Principle Backflow Preventers.

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

SINGLE STAGE END SUCTION PUMPS AURORA Series. Distributed By: Model 3804

SECTION VI Duplex Lift Station with Above Grade Valve Pit

SECTION MOTORS AND PUMPS FOR PLUMBING SYSTEMS

INSTALLATION INSTRUCTIONS

YEOMANS SUBMERSIBLE SOLIDS-HANDLING WASTEWATER PUMPS YEOMANS

AUGUST 2017 Tulpehocken Station Utility Improvements ADDENDUM 3 SECTION SEWAGE EJECTOR PUMPING STATION

MODELS PH PH PH

Simplex Fiberglass Lift Station: Hard Piped

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304

DIVISION 33 UTILITIES SECTION PACKAGED SEWAGE GRINDER PUMP UNITS

Weir Specialty Pumps. WEMCO Torque-Flow

BUILT FOR WORK THREE-PHASE PUMPS

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL and BEARINGS 303

Series description Wilo-Drain STS 40

The following document can be provided to an Engineer, Contractor, or Owner to allow them to

Pump Division MSX Solids-Handling, Submersible Pumps

Pioneer Forced Draft Cooling Tower Specifications

Flygt C-pumps Submersible waste and raw water pumps

VOGEL - Submersible Pumps in Stainless Steel Design TVS

B. System Design and Performance Requirements

SECTION SLUICE GATES

University of Houston Master Construction Specifications Insert Project Name SECTION PLUMBING PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS:

SECTION COOLING TOWER

ITEM L-119 AIRPORT OBSTRUCTION LIGHTS DESCRIPTION

300828TWP INSTALLATION INSTRUCTIONS MODEL SUBMERSIBLE SUMP PUMP

2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING

Flygt 3057, 50Hz. Technical Specification

Module 9 : Sewage And Storm water Pumping Stations. Lecture 11 : Sewage And Storm water Pumping Stations

e-hmseries STAINLESS STEEL HORIZONTAL MULTI-STAGE PUMPS BROeHM R2

Read Only Copy Not For Distribution. Chapter 17. Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.2 QUANTITY OF WATER REQUIRED

Experience In Motion MPT. Self-Priming, Solids-Handling Pump

Flygt N-Pumps 3085, 3102 & For reliable and efficient wastewater handling

LIQUID-SPECIFIC PRODUCT LINE: ABRASIVE LIQUID PUMPS SERIES DESCRIPTION OPERATING RANGE: IMPROVEMENTS NOMINAL FLOW RATES:

Pump Company. Simsite Structural Composite Pumps. The only Pump that is Impervious to Salt Water Corrosion. Since 1919 VERTICAL PIT

PNI RESIN MADE PUMPS

Introduction. Ultra Reliable

SECTION C1 DUCTILE IRON PIPE AND FITTINGS GENERAL

Technical specification. Flygt N 3301, 50 Hz

Introduction. Disclaimer. Table of contents

N-pump, Standard Motor

Experience In Motion. MPT Self-Priming, Solids-Handling Pump

Experience In Motion. TKL Primo-Titan Self-Priming, Solids-Handling Pump

SPECIFICATION : WASTEWATER PUMPING STATION

SECTION MECHANICAL SPECIFICATION GRIT COLLECTION EQUIPMENT

SECTION FIELD ERECTED INDUCED DRAFT COOLING TOWER

CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH

Pump Requirements For Residential Wastewater Application. Lakeway Municipal Utility District

HIGH MAST CAMERA POLE ASSEMBLY GENERAL

D-35 Series. Up to 37 gpm (140 l/min) D-35 Specialized Designs

Advanced Grit Removal Technology

Horizontal and Vertical End Suction Pumps

WASTEWATER PUMPING STATION INVENTORY

Autogas Series. Regenerative Turbine Coro-Flo Pumps For High Differential Pressure Applications Using LPG and Other Liquefied Gases.

TM Series Cooling Tower Specification

FYBROC SERIES 5500 FIBERGLASS CONSTRUCTION FOR CORROSIVE APPLICATIONS. Fybroc Vertical Fiberglass Sump Pumps B U L L E T I N 5 5 B 1

Flygt 3171, 50Hz. Technical Specification

Flygt 3057, 50Hz. Technical Specification

Autogas Series. Regenerative Turbine Coro-Flo Pumps. For LPG High Differential Pressure Applications

SECTION SLUICE GATES

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

Enviro Voraxial Technology

PUMP TECHNOLOGY. Are we making any progress? S. Gopalakrishnan Flowserve Corporation Pump Division Vernon, California. ASME FEDSM May 31, 2001

Fiberglass Cooling Towers

TYPES OF SEWAGE PUMPS. Solids Handling Pumps: Grinder Pumps: Effluent Pumps:

GRUNDFOS SUBMERSIBLES. Grundfos submersible pumps the complete solution

1. Vertical reciprocating conveyor, Hydraulic straddle VRC.

DETAILED EQUIPMENT SPECIFICATION MFS SERIES FILTERS

SECTION ALUMINUM GATES

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

FOUR FOLD DOORS-WITH SINGLE OVERHEAD MTD OPERATOR

Cooling Tower Depot, Inc. 651 Corporate Circle, Suite 206 Golden, CO Phone (720) Fax: (720)

ANSI/ ASME HST Performance Standard For Overhead Electric Wire Rope Hoists

SECTION HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS (PRESSURE PIPE)

Submersible Pump Fulfills Quarry Stone Washing Requirements. By Mike Bjorkman, Vice President and Director of Marketing, BJM Corp.

WXH Utility Grade Multistage, Ring Section Pump

SECTION POLYVINYL CHLORIDE (PVC) WATERLINE

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Welded System

FLUID FLOW - PUMPS. Discharge Section. Section. Two main types of pumps: Positive Displacement pumps Centrifugal pumps.

Customer-specific pump engineering

SECTION TURBINE VENTILATORS

SECTION RETRIEVABLE FINE BUBBLE DIFFUSER SYSTEMS

EC medium pressure axial fans.

REQUEST FOR PROPOSALS FOR SLUDGE DEWATERING EQUIPMENT HORTONVILLE WASTEWATER TREATMENT FACILITY VILLAGE OF HORTONVILLE.

Member Service Electric Wiring Guidelines

ERPN Overhung, End-Suction Process Pump ISO 13709/API 610 (OH2)

INDEX WARRENDER...3 OVERVIEW...4 APPLICATIONS...5. WMCA (Centrifugal alloy pumps) WMCP (Centrifugal non-metallic pumps)...

Transcription:

PERFORMANCE DATA Wholesale Products Page: 6280-1 RPM: 1650 Discharge: 2 Solids: 2 12 40 9 30 HEAD-METERS 6 HEAD-FEET 20 3 10 0 0 Capacity - U.S. G.P.M. 0 30 60 90 120 150 180 Liters/Second 0 2 4 6 8 10 The curves reflect maximum performance characteristics without exceeding full load (Nameplate) horsepower. All pumps have a service factor of 1.2. Operation is recommended in the bounded area with operational point within the curve limit. Performance curves are based on actual tests with clear water at 70 F. and 1280 feet site elevation. Conditions of Service: GPM: TDH:

DIMENSIONAL DATA Wholesale Products Page: 6280-2 Switch Diaphragm Tethered Pump ON 12-1/4 (31.1cm) 14 (35.6cm) Pump OFF 3-3/4 (9.5cm) 7-1/2 (19 cm) 11 25 /64" (289.3) 5 7 /16" (138) 4 1 /2" (114.6) 2" NPT DISCHARGE 9" (228.4) 17 /32" (13.5) 3 1 /2" (88.9) 12 49 /64" (324.5) 2 1 /16" (52.3) DISCHARGE HEIGHT PUMP Off 6 5 /16" (160.6) PUMP ON 14 1 /2" (367.9) All dimensions in inches. Metric for international use. Component dimensions may vary ± 1/8 inch. Dimensional data not for construction purpose unless certified. Dimensions and weights are approximate. On/Off level adjustable. We reserve the right to make revisions to our product (s) and the product (s) specifications without notice.

ELECTRICAL DATA Wholesale Products Page: 6280-3 MODEL: SKV40 R.P.M. 1650 MOTOR TYPE OIL FILLED WITH AUTOMATIC RESET THERMAL OVERLOAD GENERAL INSULATION CLASS B MOTOR PROTECTION AUTOMATIC RESET / THERMAL OVERLOAD HP VOLTAGE PHASE NEC CODE SERVICE FACTOR FULL LOAD AMPS 115 12 1/2 1-1 230 6

TECHNICAL DATA Wholesale Products Page: 6280-4 MODEL: SKV40 Physical Data DISCHARGE SIZE 2 SOLIDS SIZE 2 IMPELLER TYPE CABLE LENGTH PAINT RECESSED VORTEX 10 STANDARD 20 OPTIONAL PAINTED AFTER ASSEMBLY, DARK GREEN, WATER REDUCIBLE ENAMEL, ONE COAT, AIR DRIED. Temperature MAXIMUM LIQUID 140 F MAXIMUM STATOR - OIL FLASH POINT - Technical Data POWER CORD TYPE MOTOR HOUSING CASING IMPELLER MOTOR SHAFT HARDWARE O RINGS MATERIALS OF CONSTRUCTION MECHANICAL SEALS Standard: UPPER BEARING LOWER BEARING SJTW CAST IRON CAST IRON THERMOPLASTIC STAINLESS STEEL STAINLESS STEEL BUNA-N CARBON / CERAMIC SLEEVE SINGLE ROW-BALL

SPECIFICATION DATA Wholesale Products Page: 6280-5 MODEL: SKV40 1.01 GENERAL Contractor shall furnish all labor, materials, equipment and incidentals required to provide (Qty.) submersible centrifugal sewage ejector pump(s) as specified herein. The pump model covered in this specification is the. The pump furnished for this application shall be MODEL as manufactured by Hydromatic Pumps. 2.01 DESIGN CONDITIONS Each pump shall be rated H.P., volts, phase, hertz and operate at RPM. 3.01 OPERATING CONDITIONS The pump shall deliver U.S. GPM/LPS at feet/meters TDH, and handle a inch solid. The curve submitted for approval shall state, in addition to head and capacity performance, solid handling capability, amp rating, and design impeller diameter. 4.01 CONSTRUCTION Each pump shall be of the sealed submersible type, incorporating features normally found in pumps furnished for the residential market. These features include: 1. The pump inlet shall be open and clear, without screening to provide access for sewage and solids. 2. All external mating parts shall be machined and Buna N, O-Ring sealed. 3. All fasteners exposed to the pumped liquid shall be 300 series stainless steel. 4. All power cords shall be water resistant UL or CSA approved, with double insulation, and sized as a function of Amp. draw. 5.01 MOTOR AND SHAFT The stator, rotor and bearings shall be mounted in a sealed submersible type housing. Single phase motors shall be permanently split capacitor. Full Load and Locked Rotor Amps. as well as Start and Run winding resistance shall be tabulated for each pump. 6.01 BEARINGS, SHAFT AND MECHANICAL SEAL An upper sleeve and lower thrust bearing shall be required. The lower bearing shall be heavy duty single row ball bearing which is permanently and continuously lubricated and cooled by the dielectric oil which fills the motor housing. The motor shaft shall be stainless steel and sealed from the pumped liquid with a carbon ceramic mechanical seal.

SPECIFICATION DATA Wholesale Products Page: 6280-6 7.01 IMPELLER The Impeller shall be thermoplastic, ten vane, vortex design with pump out vanes on the back side. These vanes wash out grit and stringy material that will damage the shaft and mechanical seal. 8.01 AUTOMATIC CONTROL All single phase pumps should be capable of automatic operation. 9.01 PRESSURE SWITCH The single phase pumps are furnished with a pressure diaphragm switch that features a piggy-back plug that allows the pump to be operated manually without removal from the sump. 10.01 FLOAT SWITCH The pump is supplied with a tilt-sensitive wide-angle float switch which is sealed in a noncorrosive PVC enclosure. The unit is UL listed for water and sewage and CSA certified. The float switch shall also be fitted with a piggy-back plug that allows the pump to be operated manually without removal from the sump. 11.01 MANUAL CONTROL The Single Phase pumps are not supplied with any type of automatic control. A wide angle piggy-back float switch can be supplied and fitted to these pumps. 12.01 PAINTING All cast iron parts shall be painted before assembly with a water reducible alkyd air dried enamel. The paint shall be applied in one coat with a minimum thickness of 3 to 4 mils. 13.01 TESTING All pumps shall be individually tested to include the following: 1. The pump and power cord shall be visually inspected for imperfections, cuts or nicks. 2. The pump shall have a ground continuity check and the motor chamber shall be Hi-potted to test for moisture content and/or insulation defects. 3. The motor and volute housing shall be pressurized and a 10 second air leak decay test run. 4. Oil is added, and the pump is run. Voltage and current are monitored visually, electronically, and the tester listens for any noise or malfunction. USA CANADA 293 Wright Street, DelAVAN, WI 53115 WWW.HYDROMATIC.COM 269 Trillium Drive, Kitchener, Ontario, Canada N2G 4W5 PH: 888-957-8677 ORDERS FAX: 800-426-9446 PH: 519-896-2163 ORDERS FAX: 519-896-6337 Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice. 2013 Pentair Ltd. All Rights Reserved. W-01-260 (03/25/13)