A review on Present development in refrigeration jet ejector system

Similar documents
Energy and Buildings

Revue des Energies Renouvelables Spécial ICT3-MENA Bou Ismail (2015) Numerical study of a single effect ejector-absorption cooling system

Application of Two Stage Ejector Cooling System in a Bus

ANALYSIS OF REFRIGERATION CYCLE PERFORMANCE WITH AN EJECTOR

Solar Absorption Aqua-Ammonia Absorption system simulation base on Climate of Malaysia

ENHANCEMENT OF COEFFICIENT OF PERFORMANCE IN VAPOUR COMPRESSION REFRIGERATION CYCLE

K.S. Rawat 1, H. Khulve 2, A.K. Pratihar 3 1,3 Department of Mechanical Engineering, GBPUAT, Pantnagar , India

Efficiency enhancement of the ocean thermal energy conversion system with a vapor vapor ejector

a. The power required to drive the compressor; b. The inlet and output pipe cross-sectional area. [Ans: kw, m 2 ] [3.34, R. K.

PERFORMANCE ANALYSIS OF NATURAL DRAFT WET COOLING TOWER AT OPTIMIZED INJECTION HEIGHT

Renewable Energy Based Active Cooling System

20/06/2011 Seminar on Geothermal Exploitation Santiago de Chile

OUTCOME 2 TUTORIAL 2 STEADY FLOW PLANT

Investigations of N 2 O Transcritical Refrigeration Cycle Using Dedicated Mechanical Subcooling. Sanjeev Kumar 1 and Dr. D.K.

Low temperature cogeneration using waste heat from research reactor as a source for heat pump

Review Questions for the FE Examination

Performance Analysis for Natural Draught Cooling Tower & Chimney through Numerical Simulation

Numerical Simulation of Spray Cooling Gas with High Temperature and Velocity in Compressor Inter-Stage

Investigations Of Low Pressure Two-Phase Steam- Water Injector

Performance evaluation of a solar ejector-vapour compression cycle for cooling application

PERFORMANCE ANALYSIS OF ORGANIC RANKINE CYCLES USING DIFFERENT WORKING FLUIDS

Improvement of distillation column efficiency by integration with organic Rankine power generation cycle. Introduction

Conceptual Design of Nuclear CCHP Using Absorption Cycle

A Study on Automobile Air-Conditioning Based on Absorption Refrigeration System Using Exhaust Heat of a Vehicle

CONTROL VOLUME ANALYSIS USING ENERGY. By Ertanto Vetra

Experimental Study on Phase Change Material based Thermal Energy Storage System

Chapter 6 THE SECOND LAW OF THERMODYNAMICS

Experimental analysis of heat-pump integrated with solar energy

OPTIMIZATION OF THE TUBE SIZE AND THE ARRANGEMENT OF EVAPORATOR TUBE BUNDLE TO IMPROVE THE PERFORMANCE OF MED-TVC SYSTEMS

Experimental Observation for Multi Nozzle Liquid Jet Ejector for Chlorine- Aqueous Caustic Soda System at Laboratory Scale

Latest Simulation Technologies for Improving Reliability of Electric Power Systems

Exploring the Design Space with System Simulation to Manage Increasing Thermal Loads on Aircraft Fuel Systems

Waste Heat Recovery of IC Engine Using VAR System

Low-Grade Waste Heat Recovery for Power Production using an Absorption-Rankine Cycle

AN UNDERSTANDING OF EJECTOR FLOW PHENOMENA FOR WASTE HEAT DRIVEN COOLING

SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT B.Tech. [SEM IV (ME-41, 42,43 & 44)] QUIZ TEST-1 (Session: )


CFD Simulation Studies on Integrated Approach of Solar Chimney and Earth Air Tunnel Heat Exchanger for Building Space Conditioning

Steam balance optimisation strategies

Heat Load Calculation for the Design of Environmental Control System of a Light Transport Aircraft

CFD on Small Flow Injection of Advanced Accumulator in APWR

CFD Analysis of Nozzle Exit Position Effect in Ejector Gas Removal System in Geothermal Power Plant

RECYCLING LOW GRADE WASTE HEAT TO ELECTRICITY. *N. Razavinia, F. Mucciardi and F. Hassani

The Potential and Challenges of Solar Boosted Heat Pumps for Domestic Hot Water Heating

EFFECT OF AMBIENT TEMPERATURE, GAS TURBINE INLET TEMPERATURE AND COMPRESSOR PRESSURE RATIO ON PERFORMANCE OF COMBINED CYCLE POWER PLANT

In this lecture... Solve problems related to First law of thermodynamics for closed and open systems Heat engines Refrigerators and heat pumps

CFD Analysis of VARS Component (Evaporator) on ANSYS Fluent

Experimental investigation of single-phase and twophase closed thermosyphon solar water heater systems

Analysis of the corrosion test process for heat exchangers in corrosion test chambers by CFD simulation

Experimental Investigation on Heat Pump for Electric Vehicles with different refrigerant injection compressors

THERMODYNAMIC ANALYSIS OF R134A DMAC VAPOR ABSORPTION REFRIGERATION (VAR) SYSTEM

Lecture No.3. The Ideal Reheat Rankine Cycle

Modelling And Study Of Chip Tool Interactions With High Velocity Air Jet As Cooling Media

Numerical Investigation of the Combustion of Methane Air Mixture in Gas Turbine Can-Type Combustion Chamber

Thermal Analysis of Solar Flat Plate Collector

a.k.a. David N. Shaw, P. E.

A Simplified Thermal Model for a CO2 Compressor

Design of a Small Scale CFB Boiler Combustion Chamber for Laboratory Purposes

Design and Analysis of Hydraulic Oil Cooler by Application of Heat Pipe

Impellers of low specific speed centrifugal pump based on the draughting technology

Waste Heat Recovery at Compressor Stations

Investigation of Separator Parameters in Kalina Cycle Systems

MECHANICAL ENGINEERING THERMAL AND FLUID SYSTEMS STUDY PROBLEMS

ANALYSIS OF VARIOUS DESIGNING PARAMETERS FOR EARTH AIR TUNNEL HEAT EXCHANGER SYSTEM

Modeling and analyzing solar cooling systems in Polysun

Performance of a Gas Turbine Power Plant

Chapter 3.7: Cooling Towers

MATHEMATICAL MODELING OF A DOUBLE PASS UNDERFLOOR HEATING SYSTEM

ELECTROTECHNOLOGIES FOR ENERGY END-USES: APPLICATION OF MVR TO FOOD INDUSTRIES

High Bridge Combined Cycle Plant

ProSimPlus Library (Standard version + rate base option)

Multi-Variable Optimisation Of Wet Vapour Organic Rankine Cycles With Twin-Screw Expanders

Plant Utilities and Energy Efficiency CH505

SorTech package solution description

EVALUATION OF SOLAR SORPTION REFRIGERATION SYSTEM PERFORMANCE IN LATVIA

CFD analysis of coolant flow in the nuclear reactor VVER440

SOLAR COOLING: STATE OF THE ART, TECHNICAL ANALYSIS AND FIRSTS APPLICATIONS

Ph. d, Faculty of Process and System Engineering, Otto-von-Guericke University, Magdeburg,

Optimization of abrasive waterjet nozzle design for precision and reduced wear using compressible multiphase CFD modelling

40-Ton Articulated Truck Cooling System Modelling Using STAR-CCM+

Derivation of Global Parametric Performance of Mixed Flow Hydraulic Turbine Using CFD. Ruchi Khare, Vishnu Prasad and Sushil Kumar

Estimation of Boil-off-Gas BOG from Refrigerated Vessels in Liquefied Natural Gas Plant

OVERALL EFFICIENCY CONSIDERATION OF PNEUMATIC SYSTEMS INCLUDING COMPRESSOR, DRYER, PIPE AND ACTUATOR

PHYSICAL AND OPERATING CONDITIONS EFFECTS ON SILICA GEL/WATER ADSORPTION CHILLER PERFORMANCE

Hydrogen oxygen steam generator integrating with renewable energy resource for electricity generation

MULTI-OBJECTIVE OPTIMIZATION OF TURBO-EXPANDER IN ORGANIC RANKINE CYCLE SYSTEM

Kalina & Organic Rankine Cycles: How to Choose the Best Expansion Turbine?

ABSTRACT. Christopher Somers, Masters of Science, Dr. Reinhard Radermacher, Mechanical Engineering

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 03 Issue: 08 Aug p-issn:

Performance of a Combined Organic Rankine Cycle and Vapor Compression Cycle for Heat Activated Cooling

Performance Comparison of Air-source Heat Pumps Using Economizer Vapor Injection and Internal Heat Exchanger in Cold Regions

A Detail Review Comparison of Refrigeration System with and without Ejector Aakash J. Bhatt 1 Fenil S. Jariwala 2

Development of an Innovative 2.5 kw Water- Silica Gel Adsorption Chiller

Design and Off-Design Analysis of an ORC Coupled with a Micro-Gas Turbine

A Matlab-Based Program for the Design And Simulation of Wet Cooling Towers

Multi Stage Flash Desalination with Direct Mixing Condensation

COMBINED CYCLE OPPORTUNITIES FOR SMALL GAS TURBINES

CHAPTER 4 STEAM TURBINE and CYCLE HEAT BALANCE

ADVANCED PROCESS CONTROL QATAR GAS ONE YEAR EXPERIENCE

Thermodynamic Considerations for Large Steam Turbine Upgrades and Retrofits

Transcription:

Volume: 03 Issue: 0 May-201 wwwirjetnet p-issn: 239-0072 A review on Present development in refrigeration jet ejector system Abstract: This paper focuses and gives idea on the development of ejector cooling system, and also focuses ejector governing equations, or some idea gives to rapid increase in energy demand in refrigeration, most of experimental studies have been done in this field,but some researches still remains for future, like Other parameter such as the length of constant area mixing section and converging angle of constant pressure mixing are less studied because of their small influence of ejector performance A Introduction Development of cooling system working with thermal energy can avoid a rapid increase of electricity demand We have studied an ejector refrigeration cycle, which could provide cooling by using solar thermal energy Because an ejector itself is key component in this cycle to get higher performance by the suction ability, the ejector configuration design is important analysis of the behavior of refrigerant flow in the ejector is an effective way to get an appropriate ejector configuration Refrigeration system using an ejector is an interesting system because of its environmentally friendly operating characteristics low-grade thermal energy can be used to drive this system An ejector can convert low heat energy obtained from solar energy or rejected heat from many factories or any heating process to useful refrigeration, an ejector system also allows the use of Water Which is the most environmentally friendly substance As a working fluid in the system researchers are still trying to improve the ejector cooling system, investigating the effect of operating conditions Developments of industry and increase in population and higher living standards have caused a great demand of energy, and consequently energy shortage and higher prices as well as global environmental problems this forces researcher to turn to renewable energy alternatives and raises voices for seeking approaches of utilizing low- grade energies in the refrigeration field, the ejector refrigeration system provide a promising way of producing cooling effect by Mr Ajeet Bergaley 1 Ajay Kumar Jatav 2 1 Assistant Professor 2 Student 1,2 Department of Mechanical Engineering 1,2 Institute of Engineering and Technology, davv Indore harvesting waste heat from industrial process or using renewable energy, such as solar radiation and geothermal energy Which makes such systems particularly attractive in this energy conscious era They have some other remarkable merits, such as no moving parts which make them vibration free, having low initial and running cost with long lifetime, and providing the possibility of using environmentally friendly refrigerants The has also been incorporated in to other systems like vapor absorption system and vapor compression systems In order to achieve better system performance and higher energy efficiency, however the ejector refrigeration system have relatively low efficiency and difficulty in their design, which greatly limit their widespread in commercial sector and consequently a number of researches have been done to understand their working characteristics and to improve their performance and use B General working process of ejector An ejector is a flow device that allows a high pressure primary fluid to accelerate and induce a low pressure secondary fluid in to the primary fluid path As the two fluids mix through a diffuser section, a pressure recovery occurs, which enables and the ejector to fulfill the function of a compressor or a pump The term secondary means the driven, passive or enlarzed flow And the term primary means driving, motive or enlarging flow, the ejector has a simple structure of four parts, a nozzle, a suction chamber, a mixing chamber, a diffuser Show in fig,(1) pressure and velocity variation along the ejector,refers from(jianyong chen,sep/201 review of ejector application) 201, IRJET Impact Factor value: 44 ISO 9001:2008 Certified Journal Page 1043

Volume: 03 Issue: 0 May-201 wwwirjetnet p-issn: 239-0072 Selvaraj u&mani [7] Sankarl al And Mani [32] Chaiwo ngsa and Wongw ise [33] Yapic Etal [34] 0 2 2 R134 a 2:1 3 R717 :1 R134 a 8:1 2 R123 0:1 4 2:3 8 30:3 2 :38 108 kap: 142 kpa :90 003:01 2:72 012:029 03:048 0:0 83:103 012:039 \WF=working fluid, CC=cooling capacity COP=coefficient of performance Fig1 Schematic diag Of ejector and variation of pressure/ velocity along the ejector E Governing equation of ejector design C Ejector performance evaluation The most important parameters for assessing ejector performance are the entrainment ratio( µ )defined as the ratio of mass flow rate of secondary fluid (Ms) to that of the primary flow(mp) (a) Table (1), Experiment result of ejector refrigeration system under various condition Ref Chunna nond & Aphom ratana [] C C WF 3 WAT ER Ev o Te m :1 Con d Tem 22:3 Gen Tem cop 110:10 028:048 Fig2 schematic diag of ejector performance 1 Primary nozzle For a given inlet stagnant pressure Pg and temperature Tg, the mass flow through the nozzle at choking condition follows the gas dynamic equation where hp is a coefficient relating to the isentropic efficiency of the compressible flow in the nozzle The gas dynamic relations between the Mach number at the exit of nozzle 201, IRJET Impact Factor value: 44 ISO 9001:2008 Certified Journal Page 1044

Volume: 03 Issue: 0 May-201 wwwirjetnet p-issn: 239-0072 Mp1 and the exit cross section area Ap1 and pressure Pp1 are, using isentropic relations (1) 2 Entrained mixed flow mi to exit section y-y the entrained flow reaches choking condition at the y y section, ie Msy 1 For a given inlet stagnant pressure Pe, we have (2) process of the system is generalized as low grade energy Tg is delivered to the generator for vaporization,the high pressure vapor from the generator ie the primary flow, enters into the nozzle and draws low pressure vapor from the evaporator ie secondary fluid The two flows undergo mixing and pressure recovery in the ejector,the mixed flow fed into condenser where it considerably rejecting heat in to environment(qc)the liquid from condenser divided into two parts one parts goes through expansion device and then enter into evaporator to produce refrigeration effect (Qe) the rest liquid is pumped back to generator via the circulation pump and complete a cycle show in fig (3),referred from(jing Yong chen, SEP,/201) 3 Mixed flow at section m-m to section 3-3 Two streams starts to mix from section y y A shock then takes place with a sharp pressure rise at section s s A momentum balance relation thus can be derived as where Vm is the velocity of the mixed flow and fm is the coefficient accounting for the frictional loss (3) Match no of mixed flow Match no for mixed flow can be evaluated () Where, = (4) Fig3 schematic dig, of CER system with ejector Evaluate system performance by mathematical simulation method, it is quick and simple Term coefficient of performance (COP) is defined as refrigeration effect to that of work in put, G Literature review (b) Temperature and match no F System working process () (7) Shows the conventional ejector refrigeration system(cers) with two ejector models which are extensively used in refrigeration technology the working The ejector was introduced as an engineering device in the early 20 th century at the same time, researcher started to investigate its working mechanism In a paper published in 190,keenam and Neumann[3] presented the first comprehensive theoretical and experimental analysis of the ejector problem the throat area at the primary nozzle has been the most commonly researched parameter in matter by introducing needle valve inside the nozzle the effective throat area varies according with the axial position of the needle [1] Presented the first comprehensive theoretical and experimental study on ejector Their results have the 201, IRJET Impact Factor value: 44 ISO 9001:2008 Certified Journal Page 104

Volume: 03 Issue: 0 May-201 wwwirjetnet p-issn: 239-0072 distinction of being used as the basis for ejector design and analysis in almost all the subsequent researches two established technique are used for modeling ejector the constant pressure model and the constant area model Sun and Eames research contemporary operation is limited and coefficient of performance (COP) is very low widely Popular [2] varga et al worked on a similar design validating it through CFD,their simulations predicted the mass flow of the motive fluid with an average relative error of 77% along the entire range of needle positions in comparison with the measures obtained on their test stand,provide that CFD is an effective tool of validate variable geometry design [3]varga at el 2012, made a CFD analysis of the same variable geometry ejector with R12a and R00a as refrigerants design for a 1 KW cooling capacity the resulting COP was found to be 177% higher than the one of the fixed geometry ejector at low condenser pressures [4] satha Aphornratana and Ian weames 1997,describes an experimental study of a steam ejector refrigeration using an ejector with a primary nozzle that could be moved axially within the mixing chamber,the test showed that a single optimum primary nozzle position cannot be define to meet all operating conditions Each operating condition require a particular optimum nozzle position the COP and cooling capacity can be varied as much as 100% by changing the nozzle position moving the nozzle in to the mixing chamber caused COP and cooling capacity to decreases when temperature was maintained constant [] Mdennis,k 2010,in this paper uses software modeling to examine the use of variable geometry ejectors and cold stores to increase annual yield of an ejector the study concludes that a variable geometry ejector is able to increase yield by 8-13 % compared to fixed geometry ejector however 4-0% increase in solar friction in 0MJ cold storage is included compare to fixed geometry ejector [] Paul RPereira 2014 studied two geometrical factors the area ratio and the nozzle exit position can be actively controlled the control of area ratio is achieved by a movable spindle installed in the primary nozzle the influence spindle position (SP) and condenser pressure on ejector on ejector performance are studied the very good ejector performance were studied when generator and evaporator temperature are 83and 9 respectively, COP varied between 04 and 08 depending on operating conditions [7] Alejandro Gutierrez, Noel Leon 2014, studied an ejector that implements variable geometry mechanisms is proposed and evaluated using CFD simulations Change to design current ejector are also discussed Investigating the feasibility of the multiple outlet design showed that by having several orifices at the primary nozzle exit wall Thus increased entrainment ratio of the ejector by mixing of primary and secondary fluids An improvement of 823% over the base line ejector entrainment ratio was analyzed with CFD HCONCLUSION Studies on variable geometry ejector refrigeration systems involve system modeling, design, and refrigeration selection The optimal geometry parameters of ejector depend on working fluid and operating conditions Other parameter such as the length of constant area mixing section and converging angle of constant pressure mixing are less studied because of their small influence of ejector performance 1 at any given condenser, evaporator and generator temperatures Only one unique geometry will result in highest COP 2 At any given temperatures of evaporator, generator and condenser variable geometry ejector have highest COP and less solar plate area as compare to fixed geometry ejector 3 Ejector refrigeration are mechanically simple and have low investment cost However such refrigerators have relatively low COP Than other conventional refrigeration technology 4 The optimum value of the primary nozzle diameter decreases with increasing generator The optimum primary nozzle position or converging angle cannot be predefined to meet all operating condition Whereas the operating conditions are different from the design point Through a large amount of work have been conducted on ejector geometries, further efforts are still needed 1 To make a comprehensive study about the effect of operating conditions, ejector geometry and working fluid characteristics I References [1] Keenan, J H, Neumann, E P, and Lustwerk, F, "An Investigation of Ejector Design by Analysis and Experiment, " april,190,pp 299-309, [2] SVarga AC Oliveira, and B Diaconu, Experimental and numerical analysis of a variable area ratio steam ejector int journal of refrigeration,32, june,2011,pp1203-1211 [3] Varga, S, A C, Oliveira, CFD study of a variable area ratio ejector using R00a and R12a refrigerant int journal of 201, IRJET Impact Factor value: 44 ISO 9001:2008 Certified Journal Page 104

Volume: 03 Issue: 0 May-201 wwwirjetnet p-issn: 239-0072 refrigeration,3 (1), march,2012,pp17-1 [4] I, Eames,S Aphornratana,and D,W,Sun, the jet pump cycle a low cost refrigerator powered by waste heat recovery systems Int, journal of refrigeration,1, april,1997,pp711-721, [] Dennis,M and Garzoli, use of variable geometry ejector with cold store to achieve high solar fraction for solar cooling Int, journal of refrigeration,34(7), Aug,2010,pp12-132 [] Pereira,PR, Varga, S, Soares, J,Oliveira, AC,Lopes, Experimental result with a variable geometry ejector using R00a int journal of refrigeration,10, June,2014,pp101, [7] Alejandro, Gutierrez, Noel Leon, development and CFD evaluation of a high efficiency-variable geometry ejector int journal of refrigeration,7,oct2014,pp244-23 [8] BJ Huang, JMchang, CPWang, 1-D analysis of ejector performance int journal of refrigeration,22,dec1998 pp34 [9] Jian yong Chen, Sad jaralla, A review on versatile ejector application in refrigeration system int journal of refrigeration system,49, sep, 201,pp7-90 201, IRJET Impact Factor value: 44 ISO 9001:2008 Certified Journal Page 1047