CLEARLLAB LS LYMPHOID SCREEN REAGENT

Similar documents
a Beckman Coulter Life Sciences: White Paper

Flow Cytometry in the Diagnosis of Hematopoietic Neoplasia. Brent Wood MD, PhD Professor, Laboratory Medicine University of Washington, Seattle

Your Research, Revolutionized

August 2017 Changes. Flow Cytometry Checklist. CAP Accreditation Program

Your Research, Revolutionized

Boundary-breaking acoustic focusing cytometry

a Beckman Coulter Life Sciences: White Paper

Flow Cytometry SOP: 14 color flow for immune activation, senescence, and exhaustion

determine optimum instrument settings for their own instruments and establish their own daily values.

Detecting human circulating endothelial cells using the Attune Acoustic Focusing Cytometer

18/08/2011. Principles of Flow Cytometry (Practised in a Clinical Laboratory) Cytometer Components. Noel Williams Immunobiology Division of Immunology

NovoCyte Flow Cytometer

Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement

Identification of red and white blood cells from whole blood samples using the Agilent 2100 bioanalyzer. Application Note

Application Note. Assay Portability on the BD FACSVerse System. Summary. Maria Jaimes, Yibing Wang, Catherine McIntyre, and Dev Mittar

A high recovery and high purity data analysis strategy for rare abnormal plasma cell events using the DuraClone RE PC Tube

Flow cytometry has become an increasingly important

Flow Cytometry - The Essentials

Bringing the EuroFlow Concept

LONDON HEALTH SCIENCES CENTRE (LHSC) WORKFLOW COMPARISON STUDY WITH THE AQUIOS CL FLOW CYTOMETER

BD FACSCanto II. A proven research platform for maximum reliability and the highest quality results

PERFECT-COUNT MICROSPHERES

FLOW CYTOMETRY. CyAn ADP. Analyzer

The Emergence of Flow Cytometry as a Routine Diagnostic Testing Technology Right Here in Our Own Back Yard! Mike Reed February 2013

Completing the performance picture.

Guava easycyte Systems Expanding the potential of flow cytometry

Quality Control in Flow. Dr David Westerman Head of Haematopathology Peter MacCallum Cancer Centre

2. SUMMARY AND EXPLANATION

TITLE: LIVE/DEAD VIABILITY FOR CLINICAL SAMPLES

BD LSR Cell Analyzer. Performance without peer, choice without compromise

Supplemental Information Inventory

arc lamp is substituted. Before

MagniSort Mouse Hematopoietic Lineage Depletion Kit Catalog Number: RUO: For Research Use Only. Not for use in diagnostic procedures.

flow cytometry reinvented

BD IntraSure Kit IVD. Cell fixation and permeabilization reagents. 50 tests per kit Catalog No

Cellometer Vision CBA

Strategies for Assessment of Immunotoxicology in Preclinical Drug Development

Welcome to More Choice. Human Panels

PURPOSE: To delineate the subsets of human lymphocytes based on the expression profiles of different phenotypic markers by FACS analysis

EdU Flow Cytometry Kit. User Manual

BD Stem Cell Enumeration Application Guide

Instrument specifications Technology Software Host interfaces Printer interfaces Data Station Physical dimensions Weight Certifications

Single Tube, Six-Color Flow Cytometric Analysis Is a Sensitive and Cost-Effective Technique for Assaying Clonal Plasma Cells

Supplementary Appendix

XS-1000i New Sysmex 5-part diff haematology analyser with fluorescence technology

Evaluation of the Automated Immature Granulocyte Count (IG) on Sysmex XE-2100 Automated Haematology Analyser vs. Visual Microscopy (NCCLS H20-A)

From Innovative Technologies To Global Solutions

PCR SYSTEMS. a new era in high-productivity qpcr. Applied Biosystems ViiA 7 Real-Time PCR System

Flow Cytometry. Marta Argenti, PhD student. Department of Biomedical Sciences Padua

Visualization of digital data Interpretation of the visual

BD FACSCalibur. The flow cytometer for your routine cell analysis needs

The Simple Solution for CBC Testing

Resolving Stem Cell Heterogeneity Using Flow Cytometry

Anti-TdT (E ) IVD

Flow Cytometry. Flow Cytometry Basics Guide

ENUMERATION OF LYMPHOCYTES SUBSETS (IMMUNOPHENOTYPING-IPT) (CD3, CD4, CD8, CD19 & CD16/56)

Tandem Dyes: Stability in Cocktails and Compensation Considerations

AAG PRINCIPLE SPECIMEN. REF (150 tests) ANNUAL REVIEW Reviewed by: Date. Date INTENDED USE

No-wash, no-lyse detection of phagocytic cells via a phrodo BioParticles functional assay in human whole blood on the

MagniSort Mouse CD3 Positive Selection Kit Catalog Number: RUO: For Research Use Only. Not for use in diagnostic procedures.

SAMPLE. Enumeration of Immunologically Defined Cell Populations by Flow Cytometry; Approved Guideline Second Edition

BD MOSAIC h MSC CELL CULTURE ENVIRONMENT DEFINED SERUM FREE

CyFlow Cube series Appealing from every angle

Neutrophil/Monocyte Respiratory Burst Assay Kit

TaqPath ProAmp Master Mixes

SAMPLE PROCEDURE , 11/07

Qdot nanocrystal. wide range of biological investigations, Qdot nanocrystals are powerful complements

a Beckman Coulter Life Sciences: White Paper

Dry Hematology Analyzer Fast, Simple CBC Analysis Designed for the Point of Care

QuantStudio Dx Real-Time PCR Instrument

CAP Accreditation Checklists 2017 Edition

First Annual Biomarker Symposium Quest Diagnostics Clinical Trials

Automated Hematology System. Your Complete Choice

Elevated Immunoglobulins and Paraproteins

Hematology Measure #4: Chronic Lymphocytic Leukemia (CLL) Baseline Flow Cytometry

Apoptosis detection. Apoptosis assays for the Attune Acoustic Focusing Cytometer. APOPTOSIS DETECTION Attune Acoustic Focusing Cytometer

Lower spectral overlap. Optimized stain index. Innovative antibodies. Superior multicolor flow cytometry. Violet Laser Reagents: The efluor Solution

Quality Control and Assessment in Flow Cytometry

Update on the IVDR. Sue Spencer

COMPONENT NAME COMPONENT # QUANTITY STORAGE SHELF LIFE FORMAT. Do not freeze. Store at 2-8 C. Do not freeze. Store at 2-8 C.

Date. Alkaline phosphatase measurements are used in the diagnosis and treatment of liver, bone, parathyroid, and intestinal diseases.

HSC enumeration of fresh samples

Guidelines for the Diagnosis and Monitoring of Paroxysmal Nocturnal Hemoglobinuria and Related Disorders by Flow Cytometry

CD8 (SK1) IVD. Table 1 Bottling concentrations. Monoclonal mouse anti-human reagent for identification of cells expressing CD8 antigen. Catalog No.

Different Potential of Extracellular Vesicles to Support Thrombin Generation: Contributions of Phosphatidylserine, Tissue Factor, and Cellular Origin

FLOW CYTOMETRY IN CLINICAL DIAGNOSIS 4TH

Return to Web Version

Flexible, robust solutions from BSI. An In Vitro Diagnostic Notified Body. Expertise and experience. IVD regulatory solutions

Orflo Application Brief 3 /2017 GFP Transfection Efficiency Monitoring with Orflo s Moxi GO Next Generation Flow Cytometer. Introduction/Background

PrimeFlow RNA Assay. Simultaneous detection of RNA and protein by flow cytometry

Flow Cytometry. Flow Cytometry Basics Guide

Pega Care Management for Healthcare

In vivo BrdU Incorporation Assay for Murine Hematopioetic Stem Cells Ningfei An, Yubin Kang *

xcelligence Immunotherapy Kit - B Cell Killing Assay ASSAY MANUAL

Multiplex Assay Design

UniCel DxI ACCESS IMMUNOASSAY SYSTEMS

ABO Typing Discrepancies

EarlyTox Cell Integrity Kit

Protocol for FACS analysis of HeLa cell transfectants

Targeted Sequencing of Leukemia-Associated Genes Using 454 Sequencing Systems

Transcription:

CLEARLLAB LS LYMPHOID SCREEN REAGENT CE MARKED ANTIBODY COMBINATION FOR LEUKEMIA / LYMPHOMA ANALYSIS Because Your Patient is Her Everything

BECAUSE YOUR PATIENT IS HER EVERYTHING ClearLLab LS Lymphoid Screen is the first CE-IVD-marked 10-color L&L reagent. For use as an aid in the differential diagnosis of your patients with signs or symptoms of hematolymphoid malignancies, it features a standardized pre-mixed combination of 12 antibodies in a shelf-stable, unitized, dry format that meets CE-IVD clearance standards. Setting a new benchmark in standardized clinical flow cytometry, ClearLLab LS provides reliable information to support your treatment decision. For your patient s family, this decision means everything. Every Event Matters

ClearLLab LS LYMPHOID SCREEN CE-IVD-MARKED ANTIBODY COMBINATION FOR LEUKEMIA / LYMPHOMA ANALYSIS The ClearLLab LS Lymphoid Screen reagent is intended for the identification of hematolymphoid cell populations by immunophenotyping on a 10-color NAVIOS flow cytometer. The reagent can be used with peripheral whole blood and bone marrow specimens collected in EDTA (K 2 and K 3 ), ACD-A and Heparin (Lithium and Sodium) as well as lymph node specimens. The results should be interpreted in conjunction with additional laboratory and clinical findings. Pre-mixed 10-color 12 antibody tube CE-IVD-marked for use with NAVIOS flow cytometers Unitized dry reagent using Beckman Coulter proprietary format 25 tests/package Compatible with WHO 2008-Revised Classification PART NUMBER 405 nm EXCITATION 488 nm EXCITATION PB 1 KrO 2 FITC PE ECD PC5.5 PC7 APC 638 nm EXCITATION APC- AF700 3 APC- AF750 4 B74073 CD3 CD45 Kappa/ CD8 Lambda/ CD4 CD19 CD56 CD10 CD34 CD5 CD20 1. Pacific Blue 2. Krome Orange 3. APC Alexa Fluor 700 4. APC Alexa Fluor 750 Streamlined Compensation Optimize assay performance and reduce your compensation workload using the new ClearLLab Compensation Kit. Unitized dry format reagents for optimized 10-color compensation Compensation performed only once per month 5 compensations per kit

EMPOWER YOUR LAB S WORKFLOW: ACCURACY AND RELIABILITY Laboratory Developed Test Workflow TIME-CONSUMING AND ERROR-PRONE Panel Creation Method Validation Stability Testing Antibody Cocktailing Analyze literature Optimize staining procedure Establish cocktail stability Prepare antibody cocktails Choose antibody specificities Design validation study Draft SOP for cocktailing Perform quality control on cocktail Select potential fluorophor combinations Execute validation study Draft SOP for stability testing Evaluate fluorophor combinations Document validation study Repeat as necessary ClearLLab LS Simplifies the Workflow Referencing the LDT workflow above, ClearLLab LS eliminates 14 steps and streamlines 5 more. It establishes the benchmark in standardized clinical flow cytometry. LDT steps eliminated by ClearLLab LS LDT steps streamlined by ClearLLab LS Every Event Matters

Sample Processing Sample Acquisition Analysis Report Results Prepare samples according to procedure Define instrument settings Create analysis templates Correlate with additional clinical and laboratory findings Create acquisition strategy Analyze data Run samples ClearLLab LS Workflow STANDARDIZED AND STREAMLINED Sample Processing Sample Acquisition Analysis Report Results Prepare samples according to ClearLLab LS Instructions for Use Acquire data according to ClearLLab LS templates Analyze data according to ClearLLab LS templates Correlate with additional clinical and laboratory findings

SAMPLE RESULTS WITH ClearLLab LS Normal Bone Marrow 0 1023 CD10 PC7 10 3 10 3 10 2 10 2 10 1 10 1 10 0 10 0 CD45 Kro This CD45 x Side Scatter dot plot demonstrates typical components of a normal bone marrow, including granulocytes (blue), monocytes (red), lymphocytes (green), myeloblasts (pink) and B-lymphoid progenitors aka hematogones (orange). This CD19 x CD10 dot plot demonstrates characteristic CD19/ CD10 co-expression by hematogones (orange). CD19-positive B lymphocytes (green) and CD10-positive granulocytes (blue) are also noted. CD34 APC This CD34 x CD19 dot plot demonstrates characteristic CD34 expression by a subset of hematogones (orange) as well as by myeloblasts (pink). CD19-positive B lymphocytes (green) are also noted. Lymph Node with Chronic Lymphocytic Leukemia/Small Lymphocytic Lymphoma 0 1023 CD45 Kro This CD45 x Side Scatter dot plot demonstrates both normal T lymphocytes (green) and a large population of cells displaying slightly lower CD45 expression (red). 10 3 10 2 10 1 10 0 CD5 AA700 This CD5 x CD19 dot plot demonstrates both normal CD5-positive T lymphocytes (green) and CD5/CD19 co-expression characteristic of CLL/SLL. Note that this immunophenotype is not specific for CLL/SLL, and additional testing may be warranted to further characterize this process. Bone Marrow with B Lymphoblastic Leukemia/ Lymphoma 0 1023 CD45 Kro This CD45 x Side Scatter dot plot demonstrates both normal T lymphocytes (green) and a large population of cells displaying lower CD45 expression (red). 10 3 10 3 10 2 10 2 10 1 10 1 10 0 10 0 CD34 APC This CD34 x CD19 dot plot demonstrates CD34/CD19 co-expression characteristic of B lymphoblastic leukemia/ lymphoma (red). CD10 PC7 CD5 AA700 This CD5 x CD10 dot plot demonstrates CD10 expression by the B lymphoblastic leukemia/lymphoma (red) and CD5 expression by the normal T lymphocytes (green). Bone Marrow with Acute Myeloid Leukemia 0 1023 CD45 Kro This CD45 x Side Scatter dot plot demonstrates typical components of a normal bone marrow, including granulocytes (blue) and lymphocytes (green), as well as a large population of cells displaying lower CD45 expression (pink). 1023 0 CD34 APC This CD34 x Side Scatter dot plot demonstrates CD34 expression by the low density CD45 population (pink). Neither the lymphocytes (green) nor the granulocytes (blue) display CD34 expression. 10 3 10 2 10 1 10 0 CD3 PBE This CD3 x CD19 dot plot demonstrates that the normal lymphocytes (green) are split into CD19- positive B-cells and CD3-positive T-cells. The granulocytes (blue) are negative for both CD19 and CD3, consistent with their myeloid origin. The CD34-positive cells (pink) are also negative for both CD19 and CD3, as well as for CD4, CD5, and CD8 (data not shown), suggesting that they may represent acute myeloid leukemia. Additional testing is warranted to further characterize this process.

GETTING STARTED ClearLLab LS Case Book Become familiar with ClearLLab LS analysis results by using our ClearLLab LS Case Book. Cases with characteristic findings typical of common lymphoid and myeloid neoplasms are included, as are cases from patients with clinical and/or laboratory findings that suggest an underlying neoplastic process, but in which no immunophenotypic abnormality is identified. Each case includes a clinical vignette that describes the patient demographics and clinical history, case-specific listmode data files, ClearLLab LS-specific analysis templates, and analysis results. Each case concludes with an Analysis Notes section that highlights the immunophenotypic findings as well as potential pitfalls. Try It Today See for yourself. Try ClearLLab LS on your NAVIOS flow cytometer today. A free of charge demonstration kit is available. Contact your local Beckman Coulter representative, or visit beckman.com/clearllab-ls. NAVIOS Flow Cytometry Platform NAVIOS Flow Cytometers deliver highly sensitive detection, outstanding data interrogation, and exceptional workflow efficiencies. The NAVIOS enables seamless transition from lower complexity assays to advanced applications. You can trust the NAVIOS to deliver consistent results, with software tools that ensure robust quality control and audit capabilities. We offer a full suite of service level options to suit the needs of an array of laboratories or operations and our instruments are supported by our expert application engineers who provide support and training to help drive our customers success. beckman.com/coulter-flow-cytometry/ instruments/flow-cytometers/navios NAVIOS is CE marked for 10-color in-vitro diagnostic use.

Choose Beckman Coulter for Benchmark Expertise and Innovation For over 80 years Beckman Coulter has driven innovation. We remain committed to creating flow cytometry solutions that fit seamlessly into your lab s workflow. When you choose a Beckman Coulter product you re choosing expertise, innovation, and quality assurance. Contact your local Beckman Coulter sales representative. beckman.com 2016 Beckman Coulter, Inc. All rights reserved. Beckman Coulter, the stylized logo, and the Beckman Coulter product and service marks mentioned herein are trademarks or registered trademarks of Beckman Coulter, Inc. in the United States and other countries. For Beckman Coulter s worldwide office locations and phone numbers, please visit Contact Us at beckman.com FLOW-2063STE10.16