American Society of Agricultural and Biological Engineers

Similar documents
American Society of Agricultural and Biological Engineers

June 1, 2010 PARTIES INTERESTED IN EVALUATION REPORTS ON REFLECTIVE FOIL INSULATION

Thermal Bridging in Residential Construction

Insulating Attics & Crawlspaces. Roger Morrison, PE, RRC NCFI Polyurethanes

CHAPTER 26 PLASTIC SECTION BC 2601 SECTION BC 2603 GENERAL FOAM PLASTIC INSULATION

July 23, 2010 PARTIES INTERESTED IN REFLECTIVE FOIL INSULATION

NRCC Guarded Hot Box Testing (ASTM C ) for Energy Efficiency of a Total Roof Assembly

EcoTouch Insulation with PureFiber Technology

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

First Revision No NFPA [ Section No ]

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

Standard Specification for Fibrous Glass Thermal Insulation and Sound Absorbing Blanket and Board for Military Applications 1

DIVISION: THERMAL AND MOISTURE SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

Gold Bond BRAND Gypsum Sheathing

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

Application Specification:

Product Guide Specification

SECTION BUILDING INSULATION. Display hidden notes to specifier. (Don't know how? Click Here)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: RHINO LININGS CORPORATION

Report on First Revision June 2014 NFPA 5000

ESR-2072 Reissued September 1, 2013 This report is subject to renewal September 1, 2015.

THERMAL BARRIERS AND IGNITION BARRIERS FOR THE SPRAY POLYURETHANE FOAM INDUSTRY

GUIDE SPECIFICATION: DUCT LINER

Phenolic foam thermal insulation products for buildings and building services end use applications

CITY OF ORANGE BUILDING DIVISION 2016 Green Building Code Requirements For Residential Construction

CHAPTER 26 PLASTIC SECTION 2601 SECTION 2603 GENERAL FOAM PLASTIC INSULATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

ROXUL Roof and Deck Insulation Section Master Guide Specification Page 1 April 2016

1 Exam Prep Prov Module: Thermal and Moisture Protection Questions and Answers

Management, Sanitation and Diseases Prevention In Poultry Farms. Edited by. Hussein A. Kaoud Cairo University

Interpretation Variables and Common Areas of Confusion. Of the 2009 IECC

Alply CLASSIC WALL Architectural Insulated Panel Wall System

MOISTURE CONDITIONS IN WALLS AND CEILINGS OF A SIMULATED OLDER HOME DURING WINTER

ANSI/ASHRAE STANDARD , METHODS OF TESTING CHILLED BEAMS

Spray Polyurethane Foam. Insulation and Air Barrier Requirements of the 2012 I-Codes. Spray Foam Coalition

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

Retroshield XL TM. Insulation THERMO REFLECTIVE INSULATION

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

June 25, 2012 PARTIES INTERESTED IN SPRAY-APPLIED FOAM PLASTIC INSULATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: BASF CORPORATION (RIGID PU SYSTEMS)

SPECIFICATION GUIDELINE

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

ROXUL Roof and Deck Insulation Section Master Guide Specification (MONOBOARD ) Page 1 April 2016

Product Test Summaries

2013 COMMERCIAL PRODUCTS

Reflective Insulation Specification & Application Guide for Post Frame and Metal Building Construction

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) LLC

SECTION INSULATED METAL WALL PANELS. ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: TERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

RESILIENT FLOORING: Select Step Wood

Smart Vapor Retarders

SECTION Solar Control Film WINDOW FILM. Copyright ARCAT, Inc. - All rights reserved

TSX Insulation for Exposed Use ROOF WALL SPECIALTY

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: THE SPRAY MARKET, INC.

SECTION CONCRETE AND MASONRY COATINGS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: NATURAL POLYMERS, LLC

Intumescent Coatings and Spray Polyurethane Foam

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS

SECTION WINDOW FILM. Display hidden notes to specifier. (Don't know how? Click Here) Copyright ARCAT, Inc. - All rights reserved

Dependable Buildings To House Your Livestock

Originally Issued: 05/03/2013 Revised: 06/06/2016 Valid Through: 05/31/2017

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

Flexible Vapor Control Solves Moisture Problems of Building Assemblies - Smart Retarder to Replace the Conventional PE-Film

Trusted ICC ES DIVISION: ATLANTA, CGF PRO, ENERGYS. Look. Conformity! Evaluation. ICC-ES Evaluation

SECTION WINDOW FILM. A. Section Windows; windows to receive architectural window film.

Permicav XV TM NEXT GENERATION OF VAPOUR-PERMEABLE INSULATION FOR WALLS WITH CAVITIES

Understanding new Acceptance Criteria of Alternative Assemblies Thermal and Ignition Barriers over SPF

Senior Design Project for UNO. Design of the International Studies Building: An Environmental Analysis

A. Source Limitations: Obtain each type of building insulation through one source.

MBG HEAVY DUTY METAL BAR GRATING MANUAL. MBG Metal Bar Grating Division of THE NATIONAL ASSOCIATION OF ARCHITECTURAL METAL MANUFACTURERS

Local Temperature Measurements on Full-Size Systems in the Laboratory: Insight into the Extent of Thermal Bridges in Building Envelope Components

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

RESILIENT FLOORING: Hot and Heavy - Secoya

Abu Dhabi Certification Scheme for Ceiling and Wall Board Products

ISO INTERNATIONAL STANDARD. Rigid cellular plastics Spray-applied polyurethane foam for thermal insulation Part 2: Application

GAF Cornell ThermaCal Nail Base Roof Insulation Panels (RESGN421) Updated: 2/15

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

SEALING & BONDING SIKA FIRE PROTECTION SOLUTIONS

Combustible Exterior Wall Cladding Systems: An ICC Perspective

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CHEMICAL BROTHERS INTERNATIONAL, LLC

Compliance Standards of Coated SPF System: inclusive of Permax 108 or Permax 115 Acrylic Elastomeric Coating ± 100

APPROVED. Acceptable to the code official for compliance with the provisions of the applicable Code or referenced Standard.

FIBER GLASS INSULATION. Thermal. Acoustical. Fire Resistant. Moisture Control. Recycled Content. Formaldehyde-free. Air Control FIBER GLASS INSULATION

GigaCrete Specification PlasterMax. PlasterMax : Fire Rated Plaster for Direct Application over Cement Masonry Units (CMU) Interior Walls

TOTAL INSULATION ROOFS ROOFS WALLS WALLS FLOORS. Energy efficiency for construction projects Always in harmony with the environment.

November 10, 2015 Baltimore, MD. presented by

ISO 4898 INTERNATIONAL STANDARD. Rigid cellular plastics Thermal insulation products for buildings Specifications

IMPACT OF COLUMNS AND BEAMS ON THE THERMAL RESISTANCE OF THE BUILDING ENVELOPE

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

October 12, Yours very truly, Gary G. Nichols, P.E., SECB Vice President. GGN/md Enclosure Evaluation Committee

Transcription:

ANSI/ASAE S401.2 FEB1993 (R2012) Guidelines for Use of Thermal Insulation in Agricultural Buildings American Society of Agricultural and Biological Engineers ASABE is a professional and technical organization, of members worldwide, who are dedicated to advancement of engineering applicable to agricultural, food, and biological systems. ASABE Standards are consensus documents developed and adopted by the American Society of Agricultural and Biological Engineers to meet standardization needs within the scope of the Society; principally agricultural field equipment, farmstead equipment, structures, soil and water resource management, turf and landscape equipment, forest engineering, food and process engineering, electric power applications, plant and animal environment, and waste management. NOTE: ASABE Standards, Engineering Practices, and Data are informational and advisory only. Their use by anyone engaged in industry or trade is entirely voluntary. The ASABE assumes no responsibility for results attributable to the application of ASABE Standards, Engineering Practices, and Data. Conformity does not ensure compliance with applicable ordinances, laws and regulations. Prospective users are responsible for protecting themselves against liability for infringement of patents. ASABE Standards, Engineering Practices, and Data initially approved prior to the society name change in July of 2005 are designated as "ASAE", regardless of the revision approval date. Newly developed Standards, Engineering Practices and Data approved after July of 2005 are designated as "ASABE". Standards designated as "ANSI" are American National Standards as are all ISO adoptions published by ASABE. Adoption as an American National Standard requires verification by ANSI that the requirements for due process, consensus, and other criteria for approval have been met by ASABE. Consensus is established when, in the judgment of the ANSI Board of Standards Review, substantial agreement has been reached by directly and materially affected interests. Substantial agreement means much more than a simple majority, but not necessarily unanimity. Consensus requires that all views and objections be considered, and that a concerted effort be made toward their resolution. CAUTION NOTICE: ASABE and ANSI standards may be revised or withdrawn at any time. Additionally, procedures of ASABE require that action be taken periodically to reaffirm, revise, or withdraw each standard. Copyright American Society of Agricultural and Biological Engineers. All rights reserved. ASABE, 2950 Niles Road, St. Joseph, Ml 49085-9659, USA, phone 269-429-0300, fax 269-429-3852, hq@asabe.org

ANSI/ASAE S401.2 FEB1993 (R2012) Approved August 1993; reaffirmed February 2013 as an American National Standard Guidelines for Use of Thermal Insulation in Agricultural Buildings Developed by the ASAE Burning Characteristics of Thermal Insulation Subcommittee; approved by the ASAE Structures and Environment Division Standards Committee; adopted by ASAE December 1980; reconfirmed December 1985; revised February 1987; revised editorially July 1990; reconfirmed December 1991; revised February 1993; approved as an American National Standard August 1993; reaffirmed by ASAE December 1997, December 1998; reaffirmed by ANSI June 2000; reaffirmed by ASAE January 2001, February 2003; reaffirmed by ANSI February 2003; reaffirmed by ASABE and ANSI February 2008; reaffirmed by ASABE December 2012; reaffirmed by ANSI February 2013. Keywords: Buildings, Insulation, Thermal 1 Purpose and Scope This Standard establishes guidelines for evaluating and specifying the type, amount, and manner of installation of thermal insulation in agricultural buildings. The scope includes consideration of burning characteristics, insulation values, and proper installation and protection of insulating materials. 2 Normative References The following standards contain provisions which, through reference in this text, constitute provisions of this Standard. At the time of publication, the editions indicated were valid. All standards are subject to revision, and parties to agreements based on this Standard are encouraged to investigate the possibility of applying the most recent editions of the standards indicated below. Standards organizations maintain registers of currently valid standards. ASAE EP475, Design and Management of Storages for Bulk, Fall-Crop Irish Potatoes ASHRAE, Handbook of Fundamentals ASTM C177-85, Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus ASTM C236-89, Test Method for Steady-State Thermal Performance of Building Assemblies by Means of a Guarded Hot Box ASTM C518-91, Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus ASTM C976-90, Test Method for Thermal Performance of Building Assemblies by Means of a Calibrated Hot Box ASTM C1114-92, Test Method for Steady-State Thermal Transmission Properties by Means of the Thin-Heater Apparatus ASTM E84-91a, Test Method for Surface Burning Characteristics of Building Materials ANSI/ASAE S401.2 FEB1993 (R2012) Copyright American Society of Agricultural and Biological Engineers 1

ASTM E119-88, Method for Fire Tests of Building Construction and Materials FM 4880, Factory Mutual Building Corner Fire Test UBC 17-5, Room Fire Test Standard for Interior of Foam Plastic Systems UL 1040, Outline of Investigation for Insulated Wall Construction UL 1715, Test Method for the Classification of Interior Finish Material Assemblies Using a Room Fire Test 3 Definitions 3.1 An agricultural building is defined as a building primarily designed to house or store farm implements, hay, poultry, livestock, or other animal or plant products. Such a structure may be used part-time, temporarily, or seasonally for work involved with agricultural production. This structure is not to be considered a place of human habitation or one regularly used by the public. 3.2 Insulating material (insulation) is defined as any material installed for the primary purpose of reducing heat transmission. 4 Burning Characteristics Evaluation 4.1 Insulation that has passed either FM 4880, UL 1715, UL 1040, or UBC 17-5; and that has a flame spread of 25 or less and smoke production of 450 or less when tested in accordance with ASTM E84, when tested at the thickness and installation planned in actual agricultural building construction, may be installed in an exposed manner to the interior of the building. Installation assemblies not meeting these requirements shall be separated from the interior of the building by an ignition/thermal barrier as specified in 4.3. 4.2 Vapor retarders or facers that are exposed to the interior of agricultural buildings shall be tested for flame spread and smoke production in accordance with the methods presented in 4.1. Materials that do not have a flame spread of 25 or less and smoke production of 450 or less shall meet the requirements of 4.3. 4.3 Insulation, vapor retarders, or facers that have a flame spread of 75 or less and smoke production of 450 or less when tested in accordance with ASTM E84, but not meeting requirements of 4.1 or 4.2, shall be separated from the interior of the building by an ignition/15 min thermal barrier capable of providing protection comparable to 13 mm (1/2 in.) cement plaster, 13 mm (1/2 in.) fire-retardant treated plywood, 13 mm (1/2 in.) fire-rated gypsum wallboard, 3 mm (1/8 in.) mineral board, 16 mm (5/8 in.) exterior type plywood, 13 mm (1/2 in.) spray applied Zonolite 3306 (UL/FM), 25 mm (1 in.) spray applied ThermoCon (architectural white or off white only) (UL/FM), 25 mm (1 in.) masonry or concrete or other material that performs similarly when tested in accordance with ASTM E119. 4.4 Materials with a flame spread greater than 75 and/or smoke production greater than 450 when tested in accordance with ASTM E84 may need specified protection that is not addressed in this Standard. 5 Insulation Values 5.1 The insulation values of the various insulation materials shall be as established and published in the latest edition of ASHRAE Handbook of Fundamentals, or as determined by a National Voluntary Laboratory Accreditation Program, NVLAP, laboratory accredited for accepted thermal test procedures. Mean insulation temperature and heat flow direction affect the insulation values. Select values or test at conditions that are representative of expected use conditions. Accepted thermal test procedures are ASTM C518, C177, C236, C976, or C1114. Laboratory test results should be made available upon request. ANSI/ASAE S401.2 FEB1993 (R2012) Copyright American Society of Agricultural and Biological Engineers 2

5.2 Installation of the insulation shall be according to manufacturers recommendations and in a manner that will not contribute to degradation of the thermal properties of the insulation. If degradation is unavoidable, the loss in insulation value should be taken into account during the design, and long-term, aged insulation values should be used in the analysis. 5.3 The amount of insulation and thus the assembly U-values needed in agricultural buildings depends on many factors, such as the expected outside temperature, number and size of animals or quantity of plant products housed, desired inside temperature, cost of material and installation, consequences of wear and condensation, operating cost for heating and/or cooling based on present and projected costs, and critical nature of building and contents being insulated. Table 1 lists recommended minimum insulation levels for agricultural buildings. More insulation may be justified with increasing energy costs in supplementally heated buildings. Table 1 Minimum recommended overall coefficients of heat transmission, U, for insulated assemblies * (ref. MWPS) Recommended Minimum U # Values Modified Supplementally Climatic Cold Environment Heated Zone Walls Ceiling Walls Ceiling Walls Ceiling W/(m 2 K) 1 0.91 ) 0.91 0.40 0.40 0.26 2 0.91 0.91 0.33 0.40 0.23 3 0.91 0.48 0.23 0.29 0.17 Btu/(h ft 2 F) 1 0.17 0.17 0.071 0.071 0.045 2 0.17 0.17 0.059 0.071 0.040 3 0.17 0.083 0.040 0.050 0.030 * Use assembly U-values which include framing effects, air spaces, airfilms, linings, and sidings. Determine assembly U-values by testing the full assembly in accordance with ASTM C236 or C976 or calculate by the procedures presented in the ASHRAE Handbook of Fundamentals. The values shown do not represent the values necessary to provide a heat balance between heat produced by products or animals and the heat transferred through the building. # For poultry grow-out buildings, a U of 0.63 0.81 W/(m 2 K)[0.11 0.14 Btu /(h ft 2 F)] in the roof and walls is current practice. Refer to Figure 1. Where ambient temperature and radiant heat load are severe, use a U of 0.48 W/(m 2 K)[0.083 Btu/(h ft 2 F)]. Figure 1 Climatic zones (ref. Midwest Plan Service) 5.3.1 Cold buildings have indoor conditions about the same as outside conditions. Examples are machinery storages, cold free stall barns, and open front livestock buildings. Minimum insulation is frequently ANSI/ASAE S401.2 FEB1993 (R2012) Copyright American Society of Agricultural and Biological Engineers 3

recommended in the roof of these buildings to reduce solar heat gain in summer and to reduce condensation in winter. 5.3.2 Modified environment buildings rely on insulation, natural ventilation, and animal heat to remove moisture and to maintain the inside within a specified temperature range. Examples are warm free stall barns, poultry production buildings, and swine finishing units. 5.3.3 Supplementally heated buildings require insulation, ventilation, and extra heat to maintain the desired inside temperature and humidity. Examples are farrowing buildings, plant product storages, farm shops, and offices. Cold and modified environment buildings requiring supplemental heat in a small area, such as brooders in an open front building, are not classified as supplementally heated. Table 1 lists recommended minimum insulation levels for agricultural buildings. More insulation may be justified with increasing energy costs in supplementally heated buildings. 6 Installation 6.1 Insulation should be chosen and installed after due consideration is given to the temperature extremes which will be encountered. Some plastic insulations melt at elevated temperatures. Some insulations lose their fire retardation properties under long-term elevated temperature and humidity conditions. Some absorb moisture, which reduces insulation value, in high humidity conditions. Some insulations may cause corrosive reactions with building components. 6.2 The insulation or covering materials should be durable, cleanable, moisture resistant, non-toxic to livestock, and consistent with applicable FDA regulations. There should be no transfer of odor, taste, or toxicity to food and feed products stored in the building. 6.3 Insulation immediately adjacent to heaters, electrical panels and devices, and welding operations is more susceptible to fire and melting. Flammable insulation in these and other similarly hazardous areas should be protected with ignition barriers as defined in 4.3. 6.4 Extreme care shall be taken when using a torch, welder, etc., around insulation during construction or renovation of a building. A person with a fire extinguisher shall maintain a fire watch during work and for at least two hours after work is complete. 6.5 Insulation should be installed in such a manner that a reasonably uniform insulation value exists over the entire insulated area. 6.6 Insulation should be installed so that it will not unacceptably settle or sag. Insulation, if susceptible to deterioration from ultraviolet light, should be protected from the sun. 6.7 Insulation should be chosen and installed in a manner that will discourage the entrance and chewing by rodents, pecking by birds, infestation by insects, and damage by livestock. 6.8 A vapor retarder should be chosen and installed with the insulation that provides a permanent resistance to the passage of water vapor of 14.3 ng/pa s m 2 (0.25 perms) or less when installed. Vapor retarders shall be evaluated and installed in conformance with the latest edition of ASHRAE Handbook of Fundamentals. 6.9 When there is a possibility of moisture migrating through the insulation, the wall or roof section shall be constructed so that the moisture can escape on the cold side. 7 Miscellaneous Considerations 7.1 Full-scale building fire tests (ref. Hagan, 1981) conducted by insulation manufacturers on unoccupied buildings with various installation configurations, types, and amounts of insulation (all with 25 or less flame ANSI/ASAE S401.2 FEB1993 (R2012) Copyright American Society of Agricultural and Biological Engineers 4

spread ratings according to ASTM E84) show that flammable material within the building may burn rapidly due to higher heat retention in well-insulated buildings. 7.2 Because of the intense heat build up possible in a well insulated building, consideration should be given to the use of automatic heat and smoke vents or burn-out panels and skylights in large, valuable buildings. 7.3 For storage buildings with very high relative humidity (85-95%) refer to ASAE EP475 or other appropriate guidelines. Annex A (informative) Bibliography The following documents are cited as reference sources used in development of this Engineering Practice: Hagan, J. R. Proc. Conf. on Energy Conservation and Fire Safety in Buildings. Full scale building fire tests. National Academy Press; 1981 Structures and Environment Handbook. Ames: Midwest Plan Service; 1983 ANSI/ASAE S401.2 FEB1993 (R2012) Copyright American Society of Agricultural and Biological Engineers 5