An Integrated Model for Design of Soil Vapour Intrusion Mitigation Systems

Similar documents
New Models to Support Vapor Intrusion Mitigation Design

A Comparison of BioVapor and Johnson and Ettinger Model Predictions to Field Data for Multiple Sites

Vapor Intrusion Mitigation Methods & Strategies

Case Studies of Innovative Use of Tracers, Indicators and Field GC/MS for Assessing the Vapor Intrusion Pathway

Installation of Liquid Boot a spray applied membrane to reduce vapor intrusion of chlorinated solvents and radon

Evaluation of Spatial and Temporal Variability in VOC Concentrations at Vapor Intrusion Investigation Sites.

Vapor Intrusion Attenuation Factors Based On Long Term Monitoring Data

Best management practices for vapor investigation and building mitigation decisions

Case Study of Modeled and Observed TCE Attenuation from Groundwater to Indoor Air. Christopher G. Lawless Johnson Wright, Inc.

Empirical Data: Challenges and Future Directions

Oregon Guidance for Assessing and Remediating Vapor Intrusion in Buildings

Using Vapor Intrusion Subslab Barriers. Rob Carvahlo and Amanda Petrocelli EAI, Inc.

U.S. EPA s Vapor Intrusion Database: Preliminary Evaluation of Attenuation Factors

Is this the maturation Phase of Vapor Intrusion Investigations?

GAS VAPOR MITIGATION SYSTEMS

Proposed Changes to EPA s Spreadsheet Version of Johnson & Ettinger Model (and some new spreadsheet tools)

Chapter 2: Foundation

Indoor Air Quality Testing at the Middle River Complex. Indoor Air Quality Testing at the Middle River Complex. For More Information

A REVIEW OF VAPOR INTRUSION GUIDANCE BY STATE

Visqueen Ultimate HC BLOK

EPA S 2015 vapor intrusion guides What do they mean for your facility?

2. Appendix Y: Vapor Intrusion Modeling Requirements (Appendix to Statewide health standard VI guidance in the Technical Guidance Manual)

Lessons from Petroleum Hydrocarbon and Chlorinated Solvent Sites Extensively Monitored for Vapor Intrusion

RADON PREVENTIVE MEASURES FOR NEW BUILDINGS

DESIGNING COMMERCIAL SUB-SLAB DEPRESSURIZATION SYSTEMS

Soil Vapor Intrusion Training In The New Economy*

November 8, 2016 International Petroleum Environmental Conference. Tim Nickels Pastor, Behling & Wheeler, LLC

Introduction of EVAL EVOH for Geosynthetics 2011

SUB-SLAB DEPRESSURIZATION SYSTEM DESIGN AND INSTALLATION

What Is A GAS VAPOR BARRIER?

A Stakeholder s Guide to New Construction at Vapor Intrusion Sites By Lenny Siegel December, 2016

Examples of Data Collection Strategies and Methods

Radon Vent Pipe System. Labeling Performance Indicators

Soil Gas Sampling for Vapor Intrusion Assessments: Key Issues

Presented to the AEHS 26th Annual International Conference San Diego, California March 23, 2016 SANITARY SEWER CONTAMINANT MIGRATION STUDY

RADON WELLISUMP BASIN FOR NEW HOME CONSTRUCTION

by Richard D. Seifert Energy and Building Specialist Cooperative Extension Service University of Alaska Fairbanks

MEMO. Kris Hinskey

Leachate Management Leachate Control and Collection

PA Vapor Intrusion Guidance

UNDERSTANDING THE ROLE OF SEWER PREFERENTIAL PATHWAYS IN VAPOR INTRUSION. Thomas McHugh, Ph.D., D.A.B.T. Lila Beckley, P.G.

Radon in civil engineering building code, building standards, guidelines for building professionals

Florida Energy Extension Service

A Design Review of Waterproofing Codes

Vapor Barriers Under Concrete Slabs Guidance for Selection and Location

Radon Demonstration: Application of Building Code Changes in Winnipeg New Home Construction. April 2014

Radon and the Alberta Building Code 2014

Atlas Chempruf TM. Coating and Lining Systems

Microfluidic Systems for Cell Growth and Cell Migration Studies

Vapor Intrusion Regulatory Guidance and IRIS Updates with Mitigation Case Studies. Richard J. Rago Haley & Aldrich 20 June 2012

PVI Risk Pathway: Sampling Considerations

APPENDIX C. Chapter 9B-53 STANDARD FOR MITIGATION OF RADON IN EXISTING BUILDINGS

STEP UP TO THE ENERGY STAR INDOOR AIR PACKAGE. A new opportunity for leading builders to create better environments inside and out

Updated J&E Model VIAModel.xls

Empirical Data to Evaluate the Occurrence of Sub-slab O 2 Depletion Shadow at Petroleum Hydrocarbon- Impacted Vapor Intrusion Sites

Modeling the Vapor Intrusion Pathway: Revisions to the MCP GW-2 Groundwater Standards

Indoor Building Survey and Product Inventory

BUILDING SYSTEMS SLAB ON GROUND THE CUPOLEX SOLUTION. CUPOLEX Slab on Ground Solution 1

RADON MITIGATION IN BLOCKS OF FLATS

LEED v4 Building Design and Construction Quiz #8 EQ

1 Exam Prep Prov Module: Thermal and Moisture Protection Questions and Answers

Annex A STATEMENT OF WORK Radon Mitigation

Observation of Liquid-filled Window without Presence of Liquid in Test Chamber

Vapor Intrusion Issues

THE INFLUENCE OF THE AMOUNT OF FIBRE REINFORCEMENT ON THE AIR PERMEABILITY OF HIGH PERFORMANCE CONCRETE

August Vapor Intrusion Guidance FAQs

Evergreen Project Implementation Plan Instructions Low Income Housing Tax Credit Program

Drainage geocomposite workshop

Crawl Space Moisture Control

USER S GUIDE. ESTCP Project ER Vapor Intrusion Estimation Tool for Unsaturated-Zone Contaminant Sources JANUARY 2016

STANDARDIZATION IN GEOTECH SECTOR V.K.PATIL

LANDFILL GAS CONTROL SYSTEMS: DESIGN AND CONSTRUCTION CONSIDERATIONS. Mike Bradford, P.E.

IDENTIFICATION OF VENTILATION PROBLEMS IN AN UNDERGROUND BUS TERMINAL IN KOREA

Below Ground Waterproofing

Soil vapor surveys can be used for a number of purposes, including the following:

VAPOR INTRUSION FROM REGULATORY, TECHNICAL,

THE ADVANTAGES HDPE MANHOLES

Passive Monitoring: A Guide to Sorbent Tube Sampling for EPA Method 325. Nicola Watson July 2015

Air Barrier Requirements for Low-Slope Roof Assemblies Myths vs. Facts

UNO Cavity Liner System: Update & R&D Proposal Status

Specifications for Concrete Embedment Liner

Health Consultation. South Indian Bend Wash Landfill Area TEMPE, MARICOPA COUNTY, ARIZONA. CERCLIS No. AZD

Risk Assessment & Generic Assessment Criteria for Groundwater Vapours

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS

Design and Analysis of Hydraulic Oil Cooler by Application of Heat Pipe

H&H Job No. DS0-05. April 29, South Tryon Street Suite 100 Charlotte, NC

HEAT RECUPERATION IN VENTILATION SYSTEM OF BASEMENT LABORATORY

PILOT PROJECT «ILE DE FRANCE»

NUMERICAL MODEL FOR PREDICTION OF CRACKS IN CONCRETE STRUCTURES

BUILDING ENVELOPE PRODUCTS PROVIDING A FULL BUILDING ENVELOPE SYSTEM. Control Moisture Movement with Our Patented Technology

Section Asbestos Containment Procedures

Passive House II, The Design Process. Ray Rebilas, AIA - Kitchen & Associates. Harry Moody - Pennrose Properties. Mike Ferguson - S.B.

Evaluation of Vapor Intrusion from a Subsurface Diesel Plume UsingM ultiple Lines of Evidence

LANE ENTERPRISES, INC. STANDARDS & SPECIFICATIONS

COMMENTS RECEIVED ON PROPOSED GUIDANCE Land Recycling Program Technical Guidance Manual Section IV.A.4 Vapor Intrusion into Buildings from

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

5. AMCA 301 Method of Publishing Sound Ratings for Air Moving Devices. 6. AMCA 500 Test Methods for Louver, Dampers, and Shutters

COST AND PERFORMANCE BENEFITS OF DUAL LAMINATE PIPE OVER LINED STEEL

Outdoor Air Pollution. Primary vs. Secondary Air Pollutants

Transcription:

An Integrated Model for Design of Soil Vapour Intrusion Mitigation Systems RemTech 2009 October 14-16, 2009 Banff, Alberta Soil Contamination Chemical vapor Migration Water Table Dr. Ian Hers Golder Vancouver; Gabriele DiMarco, Golder Brisbane; Graeme Miller, Golder Adelaide

Presentation Outline Vapour intrusion mitigation overview Vapour intrusion mitigation experience Modified Johnson and Ettinger model for incorporating venting and barrier Civil design module for venting layer design Conclusions

Vapour Intrusion Mitigation Context May be required at sites with VOCs (e.g., chlorinated solvents), radon, methane Increased emphasis on pre-emptive mitigation at Brownfield/methane generating sites (e.g., ASTM E2600) Challenge is no standard practice for design and wide range of options available 1 1. Some Guidance: UK CIREA 149 & 665; British Standards 8485:2007; Requirements Los Angeles & San Diego

Vapour Intrusion Mitigation Options Passive or active (depressurized) sub-slab venting Barrier below building (for new buildings) Building-based measures Sealing of floor slab openings Increased building ventilation Building pressurization Soil vapour extraction Key points: Mitigation solution will depend on contaminant type, concentration, flux and building; Typically subslab venting with barrier where needed (and feasible) is the most effective solution

Radon Mitigation Experience Sub-slab depressurization (SSD) combined with sealing of cracks most commonly used technology Comprehensive USEPA study 1 compared sub-slab depressurization, slab sealing and house pressurization, found that sub-slab depressurization was most effective method SSD often > 90 % reduction in radon concentrations Sealing floors alone <= 50 % reduction Passive venting alone: Vent connected to stack open to atmosphere: 30% reduction in radon entry 2 1 Installation & Testing of Indoor Radon Reduction Techniques in 40 Eastern Pennsylvania Houses, EPA Report 600/8-88/002 (400 pg) 2 Holford, D.J. & Freeman, H.D. Effectiveness of a Passive Subslab Ventilation System in Reducing Radon Concentrations in a Home. Environ. Sci. Technol. 1996, 30, 2914-2920.

Residential/ Application Small Commercial Usually 1 to 2 ( radon ) sumps 90-150 Watt fans 80 to 95% reduction typical ~~ 2-3 $/SF

DCE Concentration (ug/m3) 100 10 1 0.1 0.01 SSD Performance (Redfield, D.Folkes) NO MODIFICATIONS REQUIRED (for ~ 75% houses, 25% needed additional sumps/ larger fans) -300-100 100 300 500 Days After System Installation Action Level EFFICACY OF SUB-SLAB DEPRESSURIZATION FOR MITIGATION OF VAPOR INTRUSION OF CHLORINATED ORGANIC COMPOUNDS DJ Folkes* and DW Kurz Indoor Air 2002

Building-based Vapour Intrusion Mitigation Measures May be effective for some buildings (e.g., commercial) depending on reduction in vapour concentrations needed Increased building ventilation Up to ~ 50% reduction possible, energy cost Can install heat recovery ventilator for houses Building pressurization May be difficult to achieve constant positive pressure Energy cost associated with heating outdoor air May need expertise of HVAC engineer!

Moffett AFB Hanger (D. Brenner, AWMA, 2006)

Moffett AFB D. Brenner, AWMA, 2006

Diagnosis Good Seal? (Pete Granholm, Apex) Thermal Digital Camera

Thermal Image of Same Wall (Pete Granholm, APEX)

Guidance on J&E Inputs: Crack Ratio (η)

Vapour Intrusion Mitigation Matrix Energy Input Efficiency Assumes pipe losses small Barrier Increased Protection Key points: Multiple combinations possible and opportunities for optimization. Be careful of cost implications (e.g., membranes & complex foundation)

Design Innovations Selection of appropriate barrier material Conventional: PVC, HDPE Newer: PVC alloy, Synthetic fibre-reinforced linear LDPE with aluminium composite, STEGO 15 mil polyolefin resins, Liquid boot asphaltic emulsion, Geoseal Wind turbines Golder has developed computer program to optimize design Geocomposites Aerated floors Vacuum [Pa] 250 200 150 100 50 0 Ventilator Turbine Performance 0 10 20 30 Wind Speed [km/h]

Surrey, BC Methane Mitigation New Buildings Single course, high build, polymer modified asphaltic emulsion

Cupolex Pontarolo

Modified Johnson and Ettinger VI Model Case Study Commercial buildings proposed at large site with extensive, very high concentrations of chlorinated solvents (trichloroethylene, perchloroethylene, many others) Baseline modeling predicted unacceptable risk Modified Johnson and Ettinger model to enable simulation of barrier and subslab venting layer Objective of modeling provide insight on effectiveness of mitigation (not rigorous design tool!)

Johnson and Ettinger (1991) Conceptual Model J&E Model Well-Mixed Diffusion [pseudo-steady state] Source [steady or transient] enclosed space Venting Layer Added vapor migration Vapor Source Barrier Depressurized building (baseline) Advection + Diffusion

Barrier Design Important property is permeation rate (not the same as vapor diffusion rate) Limited literature (Haxo 1984, Park 1995, Sangan and Rowe, 2002; McWatters 2007, product specifications) Liquid Boot 1.5 mm PCE vapor diffusion rates: 2.7x10-14 to 8.1x10-14 m 2 /sec McWatters (2007) BTEX permeation rates BTEX: HDPE 10-11 to 3x10-10 m 2 /sec; PVC 2x10-10 to 10-9 m 2 /sec Similar to diffusion rate of benzene in water Be careful if designing system with just barrier (relying on diffusive gradients) Barrier

Barrier Design Barrier 1 mm What is effect of 1 mm thick geomembrane on overall effective diffusion rate? Soil 1 m 1 mm thick Geomembrane Effective Diffusion Coefficient 1 m Sandy Soil Combined Geomembrane and Soil 1x10-9 m 2 /sec (High) 7.4x10-7 m 2 /sec 4.3x10-7 m 2 /sec 8x10-14 m 2 /sec (Low) 7.4x10-7 m 2 /sec 8x10-11 m 2 /sec Effect is a little to a lot depending of values used!

But what about holes in barrier? No barrier is 100% effective (utilities, holes in barrier due to construction) Diffusion rates through holes and cracks will be much higher than through barrier itself (also advection through cracks) For modeling shown on subsequent slides assumed barriers with openings, with diffusion limited to openings Assumed 10 leaks that are 10 cm 2 in size per 1,000 m 2, which corresponds to a crack ratio of 1x10-5.

Modified J&E VI Model Scenarios Model Scenarios Air-changes venting layer Building Depressurization Baseline (no mitigation) 0 2 Pa Eliminate pressure 0 0 Pa gradient Venting Layer 2 per hour 0 Pa Venting Layer & Barrier 2 per hour 0 Pa

Modified J&E Model Results Model Scenarios Attenuation Factor Baseline (no mitigation) 2.5x10-5 Eliminate pressure gradient (ΔP) 4.1x10-6 Eliminate ΔP, add venting layer 9.3x10-7 Eliminate ΔP, add venting & barrier 1.9x10-8 Eliminate ΔP: ~ 6X reduction in attenuation factor Add venting layer: ~ 4X additional reduction Add barrier: ~ 50X additional reduction Key points: Combination of measures needed to meet objectives. Somewhat unexpectedly was limited reduction for venting (for assumptions made)

Golder Venting Design Module Objective is to enable design/optimization of subslab venting layer and piping based on desired pore flushings Couples flow through piping and soil based on civil engineering principles Spreadsheet model developed by Golder

Golder Venting Model BASIS RESULTS ASSUMPTIONS Bernoulli Law Civil Objective Pressure for engineering Perfect drop is near-constant Fluid relative principles to atmospheric flow to calculate in the gravel pressure Mass Conservation loss blanket required through meeting Principal to achieve orifices pore desired and flushings piping flow rate and required air flow in will the Extended Darcy s depend exhaust Law on pipe pressure losses in soil and piping Pa, Vi AIR INLET SLOTTED PIPE GRANULAR BLANKET Vg ~ const. VAPOUR COLLECTION DRAIN Pf, Vf

Golder Venting Model Discretisation Vi Vi+1 Darcy s Law Air Flow q = k/μ ΔP soil /ΔX soil Ve Vg ~ const Ve+1 Gravel Air Conductivity Gravel Blanket Flow ρ a μ k a = kq w g = ρw μa Where: Aw t n N En Where: A = Building footprint area n ρ = Gravel air/water Blanket density Porosity (Pa/m2); N = no of conceptualised μ = corridor air/water dynamic viscosity (Pa/sec). En = no of desired exchange per hour

Golder Venting Model Results Pressure [Pa 0-5 -10-15 -20-25 -30-35 -40-45 -50 Head Loss vs Distance Intake slotted pipe Geocomposite Intake Solid Pipe Outlet Solid Pipe 0 10 20 30 Distance [m] From this pumps can be sized

Conclusions Subslab venting typically combined with barrier is effective technology for reducing VI Large range of options for design, but little design guidance or tools, nonetheless we can improve upon a liner and some whirligigs should work? Assessment tools can couple vapour intrusion modeling and civil engineering design mitigation modeling Opportunities for optimization of design Solutions will be site specific (e.g., may be different for methane compared to chlorinated solvent sites)