ROOF REPORT 3130 TCHULAHOMA

Similar documents
CITY OF RICHMOND PINE CAMP COMMUNITY CENTER ROOF REPLACEMENT PROJECT RCS PROJECT NO

Lithia Dodge East 5500 L St. Omaha, NE

Commercial Roof Cover Maintenance and Repair Risk Engineering Your Business Insurance Specialists

GAF Scheduled Maintenance Checklist

ROOFING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION

DUKE UNIVERSITY CONSTRUCTION STANDARDS

MULE-HIDE PRODUCTS CO., INC. MULE-HIDE SELF-ADHERING TPO ROOFING SYSTEM

NOTES FROM THE FIELD FLAT ROOFS AND MASONRY IN NEW YORK PETER MARCIANO

Margaret Batts Tobin Laboratory

APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET

Facility Assessment Report, Montgomery Independent School District

MAKE ROOFS LAST LONGER

Roof Replacement. Notes: T-1 (Title Sheet) Roof Key Plan Russell House Student Union 1400 Greene Street Columbia, South Carolina 29208

SECTION CLAY BARREL TILE ROOFING. A. American Society for Testing and Materials (ASTM):

SECTION PREPARATION FOR RE-ROOFING

City of Republic Community Development Department. Residential Roofs REVISION DATE: JANUARY 2017

CITY OF CITRUS HEIGHTS BUILDING & SAFETY DIVISION

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

Product Technical Bulletin SPM-4H-250

Inspection & Maintenance of Concrete Facilities By Cheyenne Wohlford CCS GROUP, LLC

Finestone Stucco System

Encapsulated, Sealed & Closed Crawlspace Installation Manual

Finestone Stucco Ultra Wall System

QUALITY COATING & REPAIR PRODUCTS

A Design Review of Waterproofing Codes

Building Envelope Systems Exam Learning Objectives

APPLICATION SAFETY TOOLS REQUIRED

DESIGN GUIDELINE FLUID-APPLIED WATERPROOFING

Crawl Space Moisture Control

SECTION G RELIEF VENTS A-0

Product Technical Bulletin APS-5T

FIRESTONE ULTRAPLY TPO SA APPLICATION GUIDE

1 Exam Prep. Roofing Practice Exam 9

FOAMULAR Insulation, PRMA, Horizontal Waterproofing

Table of Contents. Division 2 Site Work Site Preparation Site Demolition Tree Protection Excavation, Trenching, and Backfilling for Utilities

Viking Enviroclad Waterproofing Membrane. EC01 Enviroclad Drip Edge Specify from the above three options

HALIFAX HUMANE SOCIETY BOARDING AND GROOMING FACILITY SECTION STYRENE-BUTADIENE-STYRENE (SBS) MODIFIED BITUMINOUS

TPO and PVC Roof Flashings and Accessories

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS

TECHNICAL INFORMATION

RAPID STRUCTURAL ASSESSMENT REPORT

FLAT ROOF REPAIR CUT COST WITHOUT CUTTING CORNERS

Good roofing practice has

Trims for flat roofing. GRP Trims for flat roofing

Building Inspection Report

the HOME REFERENCE BOOK the encyclopedia of homes

EMERGENCY MANAGEMENT PREPAREDNESS AND ASSISTANCE TRUST FUND ARC 4496 Evaluation Questionnaire

TELEPHONE: (215) Addendum No. 1

ITEM 458 WATERPROOFING FOR STRUCTURES

METAL ROOFING: RE-ROOFING QUESTIONS & ANSWERS

PART 3 GENERAL REQUIREMENTS

Building Enclosure Detailing for Balconies

SCOPE OF WORK PROJECT IDENTIFICATION

Galvanized Steel TECHNICAL BULLETIN #1

TOPCOAT Restoration Specifications Structural Concrete

The conditions, recommendations, suggestions contained herein are the result of a visual inspection as of this date.

Background. BSC Website Builder Resources. Building America Innovations

Firestone Polyiso Boards

SECTION MANUFACTURED ROOF EXPANSION JOINTS

TOPCOAT Restoration Specifications Fiberglass & MB Granulated Cap Sheets

Outline NBS Specification. Protec System to PVC Single Ply (Waterproofing Only)

PLATON FOUNDATION WRAP

Homebuyers Survey. Final Report. Mr Client. A Home, A Street, A Town. 3rd July 2014

Cheldelin Middle School

SPACE TYPE: OUTSIDE PARKING (STRUCTURE)

Seasons Business Center New Construction!

11 FLAT ROOF CONSTRUCTION

LEGACY REPORT DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FLUID APPLIED ROOFING REPORT HOLDER: CONKLIN COMPANY INC.

PLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION

SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 811 [2013] Appraisal No. 811 (2013) Amended 28 August 2017

SECTION STYRENE-BUTADIENE-STYRENE (SBS) MODIFIED BITUMINOUS MEMBRANE ROOFING

Selection, installation and USage of HatcHeS

SECTION CO-POLYMER ELASTOMERIC COOL-ROOF COATING

Thermoplastic Single Ply & Multi-Ply Roofing Systems

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.

RIVERS EDGE CONDOMINIUM ASSOCIATION MAINTENANCE RESPONSIBILITIES

SECTION ALPHAGUARD RESTORATION 20 YEAR WARRANTY SYSTEM. f. Conditions and Division 01 Specification Sections, apply to this Section.

FireShield System Specifications Mineral Surface Cap, Mop Granule and Torch Granule APP Cap Sheets

Total Performance WARRANTY for T. Clear Roofing Products. For a period of ten (10) years from the date of completion (

For 17 years, IRSI has been providing the CAT 5 Roof Design with Guaranteed Hurricane Protection

REQUEST FOR QUALIFICATIONS AND PROPOSALS. On Behalf of the Crawford County Board of Commissioners. for

Exterior Stucco and Siding Installation

INTRODUCTION. Inspection Procedures oinitial Inspection Report. Visual Inspection Physical Sampling (Core and Slit Samples)

Carpenter Level 2 Rev. September 2017

System Specifications

DURA 500 THERMOPLASTIC FLAT ROOF COATING SYSTEM BY SUPERIOR POLYMERS INC.

Standard specification for the application of Danosa Two-Layer waterproof roofing membrane to plywood & concrete surfaces.

Radon Vent Pipe System. Labeling Performance Indicators

The Experts in Retrofit Design. Retrofit Solutions. Retro-R SSR NuRoof NuWall

Chapter 2 Understanding The Problem

Protective Coatings for Underground Utility Concrete Structures. By: John E. Davis Inside Sales & Marketing Specialist: Sauereisen, Inc.

UNIFIED FACILITIES CRITERIA (UFC) ROOFING

Table of contents. Property Inspection Information. Important: Please Read Carefully. Inspection Company Information

SECTION 806 MANHOLE REHABILITATION

SECTION PVC SINGLE PLY ROOFING

A. Coordinate Roof Assembly roof insulation work with work before and after. See especially:

Engineered Roof Solutions

Rockland Library Assessment Executive Summary

Transcription:

ROOF REPORT 3130 TCHULAHOMA MEMPHIS, TENNESSEE BUILDING OWNER: Memphis Shelby County Airport Authority BUILDING MANAGER: MSCAA SURVEY DATE: 6/12/17 BUILDING CONSTRUCTION COMPLETED: 1985 ROOF AREA (SF): 200,000 WALLS: Precast concrete FRAMING: Steel DECK: 1 1/2" steel SLOPE (IN PER FT): 1/4± ROOF EDGE: Gravel guard east and west, very low parapet north and south ROOF ACCESS: Interior fixed ladder and roof hatch DRAINAGE SYSTEM: Gutters and downspouts to storm system OVERFLOW: N/A SPECIAL FEATURES: Metal canopy in various places on west side. (Photo 1, not inspected) ROOF SYSTEM COMPLETED: Unknown, estimated 2001 ROOFER: Unknown COMPOSITION: Emulsion coating, 3-ply built-up (PPR), wood fiber cover board (damp where cored), 1.75 polyisocyanurate insulation, total thickness 2-5/8 WARRANTY: N/A BIGHAM ROOF CONSULTING 9160 Hwy 64, Ste 12 PMB 135, Lakeland, TN 38002-8094 (901)606-8254 fax (901)205-1963 jbigham@bighamroof.com

CONDITION GENERAL CONDITION: Poor. There are numerous splits, mostly in the South Section. (Photo 2) Most have been patched (Photo 3), but in some cases, the splits have lengthened past the patches (Photo 4), and in many other cases, the patches have split. (Photo 5) Much of the emulsion coating has worn away, and in many places the asphalt coating on the felts has eroded exposing the matt. (Photo 6) LEAK REPORTS: Leaks have been reported in the South and Center Sections. A large portion of the building is unoccupied, and some leaks may go unreported. The core sample taken in the south section was damp. SPECIFIC PROBLEMS: 1. Many of the gravel guards have been restriped in, but many of the repairs are failing and the other gravel guards need to be stripped in again. (Photo 7) 2. Most of the pipe penetrations are pitch pockets filled with roofing cement, and the cement is shrinking. (Photo 8) 3. Gutters are rusting. (Photo 10) Also, the gutters have no expansion joints and can be assumed to be leaking. (Photo 11) 4. The three sections of the roof are divided by area separation joints. The one between the South and Center Sections of the roof is covered by metal and could be maintained a while longer. (Photo 11) The one between the Center and North Sections of the roof is covered by a bellows type expansion joint cover and is damaged in a number of places. (Photo 12) 5. At least one of the air conditioning units discharges condensate onto the roof. (Photo 13) A continual supply of water on an asphalt based roof will deteriorate it. LIFE EXPECTANCY: South Section none, Center and North Sections 1 to 2 years. SUMMARY CONCLUSIONS: With many more splits, the South Section is in worse shape than the other two. Why is not clear. It may be older. With the air conditioning units there, it has had more traffic, but the area with the splits goes beyond where most of the traffic would have been. Regardless of the reason, the roof is at the end of its life and should be replaced. The South Section should be replaced immediately. The other two section could be repaired and maintained for another year or two, but it would cost less and be more practical to do all at once. Because there is only one roof, the roof can be overlaid with another roof system. Before doing so, an infrared moisture PAGE-2

scan should be performed to identify areas of wet insulation. All wet insulation should be removed before installing the new roof. If more than ten percent of the insulation is wet, tear all the roofing off down to the deck. RECOMMENDATIONS: 1. As with any commercial roof, clear it of debris quarterly or as experience dictates. This particular roof was fairly clean, but it would be a good idea to cut overhanging trees back. (Photo 14) 2. Have a roofer inspect it annually and make repairs as needed before they become leaks. 3. Perform an infrared scan of the roof and mark off areas of wet insulation. Replace wet insulation. If the area is greater than ten percent of the roof, tear off the entire roof down to the deck. 4. Install polyisocyanurate insulation, cover board and a modified bituminous roof. The roof can be expected to last 20 to 25 years. A less expensive alternative is a.060 TPO roof with polyisocyanurate insulation. It will cost about half as much and last half as long. It is also more easily punctured and can have a higher maintenance cost. 5. Replace gutters and downspouts. Gutters should include expansion joints. Replace all gravel guards and copings. 6. Pitch pockets should be avoided. If they are used, they should be filled with self-leveling (pourable) polyurethane sealant. 7. Pipe all condensate drains to sanitary sewer. -John T. Bigham, RA RRC CCS June 28, 2017 6-28-17 PAGE-3

NORTH SECTION AREA SEPARATION JOINT CENTER SECTION AREA SEPARATION JOINT SOUTH SECTION CORE SAMPLE ROOF HATCH AERIAL-1

Photo 1 Photo 2 Photo 3 PHOTOS-1

Photo 4 Photo 5 Photo 6 PHOTOS-2

Photo 7 Photo 8 Photo 9 PHOTOS-3

Photo 10 Photo 11 Photo 12 PHOTOS-4

Photo 13 Photo 14 PHOTOS-5