Application Note. Author. Abstract. Small Molecule Pharmaceuticals & Generics. A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany

Similar documents
Disulfide Linkage Analysis of IgG1 using an Agilent 1260 Infinity Bio inert LC System with an Agilent ZORBAX RRHD Diphenyl sub 2 µm Column

Technical Overview. Author. Abstract. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Application Note. Author. Abstract. Biopharmaceuticals. Verified for Agilent 1260 Infinity II LC Bio-inert System. Sonja Schneider

Application Note. Author. Abstract. Small Molecule Pharmaceuticals. Sonja Krieger Agilent Technologies, Inc. Waldbronn, Germany

Fraction Analysis of Cysteine Linked Antibody-Drug Conjugates Using Hydrophobic Interaction. chromatography. Agilent 1260 Infinity II Bio-Inert System

Peptide Mapping: A Quality by Design (QbD) Approach

Characterization of mab aggregation using a Cary 60 UV-Vis Spectrophotometer and the Agilent 1260 Infinity LC system

Quality-by-Design-Based Method Development Using an Agilent 1290 Infinity II LC

Size Exclusion Chromatography of Biosimilar and Innovator Insulin Using the Agilent AdvanceBio SEC column

Qualification of High-Performance Liquid Chromatography Systems

Characterize Fab and Fc Fragments by Cation-Exchange Chromatography

mab Titer Analysis with the Agilent Bio-Monolith Protein A Column

Method Translation in Liquid Chromatography

Controlling Agilent 1200 Series Rapid Resolution LC systems through Waters Empower chromatography data software. Technical Overview.

Application Note. Author. Abstract. Biotherapeutics and Biologics. Sonja Schneider Agilent Technologies, Inc. Waldbronn, Germany

Heart-cut 2D-LC/MS approach for pharmaceutical impurity identification using an Agilent 6540 Q-TOF LC/MS System

Agilent AdvanceBio SEC Columns for Aggregate Analysis: Instrument Compatibility

Analysis of Monoclonal Antibody Digests with the Agilent 1290 Infinity 2D-LC Solution

Cell Clone Selection Using the Agilent Bio-Monolith Protein A Column and LC/MS

Analysis of Intact and C-terminal Digested IgG1 on an Agilent Bio MAb 5 µm Column

Application Note. Author. Abstract. Environmental. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Quantitative determination of residual 2-(2-chloroethoxy) ethanol (CEE) in quetiapine fumarate by gas chromatogaraphy

Forced Degradation of Ibuprofen in Bulk Drug and Tablets

Improving Resolution and Column Loading Systematically in Preparative Liquid Chromatography for Isolating a Minor Component from Peppermint Extract

Analysis of USP <467> Residual Solvents using the Agilent 7697A Headspace Sampler with the Agilent 7890B Gas Chromatograph

Confident Pesticides Analysis with the Agilent LC/Triple Quadrupole and TOF/QTOF Solutions

A Fast and Robust Linear ph Gradient Separation Platform for Monoclonal Antibody (MAb) Charge Variant Analysis

Fast Preparative Column Liquid Chromatography (PCLC)

EPA Method 543: Selected Organic Contaminants by Online SPE LC/MS/MS Using the Agilent Flexible Cube

Optimizing the Purification of a Standard Chiral Compound Utilizing a Benchtop, Multi-Purpose, Semi-Preparative to Preparative HPLC System

Concentration of Human Hormones in Drinking Water Using Solid Phase Extraction and Analysis by High Performance Liquid Chromatography

Analysis of Monoclonal Antibody Digests with the Agilent 1290 Infinity 2D-LC Solution Part 2: HILIC RPLC-MS

Lifetime stability of size exclusion chromatography columns for protein aggregate analysis

Flexibility with. Preparative HPLC

Agilent 7820A GC System THE EASY CHOICE FOR ROUTINE ANALYSES

Application Note. Abstract. Authors. Introduction. Environmental

INTERNATIONAL PHARMACOPOEIA MONOGRAPH ON ARTEMETHER AND LUMEFANTRINE CAPSULES REVISED DRAFT FOR DISCUSSION

Technical Overview. Authors. Abstract. Verified for Agilent 1260 Infinity II LC Bio-inert System

Chem 321 Lecture 23 - Liquid Chromatography 11/19/13

A universal chromatography method for aggregate analysis of monoclonal antibodies

Overview of preparative HPLC. Analytical Technologies Limited

Agilent 1220 Infinity II LC GET ON THE FAST TRACK TO HIGHEST EFFICIENCY AT A PRICE YOU CAN AFFORD

HIC as a Complementary, Confirmatory Tool to SEC for the Analysis of mab Aggregates

Development of Ultra-fast ph-gradient Ion Exchange Chromatography for the Separation of Monoclonal Antibody Charge Variants

Fast and High-Resolution Reversed-Phase Separation of Synthetic Oligonucleotides

High Resolution Analysis of Heparin and Heparin-like Impurities on Glycomix TM an Anion Exchange Column

Preparative HPLC is still the

Genotoxicity is the property of a compound

An Automated System for At-Line Process Analysis of Biopharmaceutical Fermentation Reactions

ZORBAX StableBond HPLC Columns

Research Paper Development of Stability Indicating Reverse Phase HPLC Method for Aripiprazole from Solid Dosage form

Precise Characterization of Intact Monoclonal Antibodies by the Agilent 6545XT AdvanceBio LC/Q-TOF

On-line SPE-LC/MS/MS to Detect Organonitrogen and Triazine Pesticides at 10ng/L in Drinking Water

HPLC METHODOLOGY MANUAL

ADVANCE ACCURACY AND PRODUCTIVITY FOR FASTER ANALYSIS

Developing Robust and Efficient IEX Methods for Charge Variant Analysis of Biotherapeutics Using ACQUITY UPLC H-Class System and Auto Blend Plus

Minimize Method Development Time for Pesticide Screening Using LC/MS Application Kit

C196-E067A. Prominence UFLCXR. Shimadzu Ultra Fast Liquid Chromatograph

Agilent 7693A Series Automatic Liquid Sampler. Inject new performance into your gas chromotography

PLRP-S Polymeric Reversed-Phase Column for LC/MS Separation of mabs and ADC

Agilent 7693A Series Automatic Liquid Sampler INJECT NEW PERFORMANCE INTO YOUR GAS CHROMATOGRAPHY

Available Online through (or) IJPBS Volume 2 Issue 3 JULY-SEPT Research Article Pharmaceutical Sciences

Characterization of Glycosylation in the Fc Region of Therapeutic Recombinant Monoclonal Antibody

Gas Chromatography Assignment Chem 543/443

Analysis of 16 Pesticide Residues in Broccoli Using CarbonX dspe QuEChERS AOAC Kits Using GC/MS

Agilent 7693A Series Automatic Liquid Sampler INJECT NEW PERFORMANCE INTO YOUR GAS CHROMATOGRAPHY

APPLICATION NOTE. UOP : Analysis of Trace CO and CO 2 in bulk H 2 and Light Gaseous Hydrocarbons by GC

Preparative HPLC: Factors and Parameters that Directly Affect Recovery of Collected Fractions

ACQUITY UPLC. I-Class PLUS WHAT SEPARATES YOU FROM EVERYONE ELSE

Bio-Monolith Protein G Column - More Options for mab Titer Determination

Analytical Methods Development and Validation

Chromatography Column Performance and Data Analysis Success Guide. Hints and Tips for Better Purifications

A green HPLC technique with a 100% water mobile phase for detecting imidacloprid and its metabolite 6-chloronicotinic acid

Validated Stability-indicating assay method for determination of Ilaprazole in bulk drug and tablets by high performance liquid chromatography

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology

UFFLC of the Proteome Ultra High Pressure and Ultra Fast Flow Liquid Chromatography: A New Approach To Proteomics

Protein-Pak Hi Res HIC Column and HIC Protein Standard

Exploring Extra Sensitivity Using ionkey/ms with the Xevo G2-XS Q-Tof HRMS for Small Molecule Pharmaceutical Analysis in Human Plasma

Peptide Mapping of Glycoprotein Erythropoietin by HILIC LC/MS and RP-LC/MS

PAHs in Surface Water by PDA and Fluorescence Detection

AZURA Bio LC. 2 FPLC and Purification Solutions

The Theory of HPLC Gradient HPLC

Accurately Identify and Quantify One Hundred Pesticides in a Single GC Run

7 Preparative Columns

Method Development Considerations for Reversed-Phase Protein Separations

Quantification of Drug Metabolites in Early-Stage Drug Discovery Testing

Antibody Analysis by ESI-TOF LC/MS

International Journal of Pharma and Bio Sciences DEVELOPMENT OF ACCELERATED STABILITY PROTOCOL FOR SILDENAFIL TABLETS A EUROPEAN PERSPECTIVE REVIEW

AZURA Bio purification

RP-HPLC METHOD FOR QUANTITATIVE ESTIMATION OF GLATIRAMER ACETATE FOR INJECTION IN PHARMACEUTICAL DOSAGE FORMS

Analysis of Suspected Flavor and Fragrance Allergens in Cosmetics Using the 7890A GC and Capillary Column Backflush Application

A Modular Preparative HPLC System for the Isolation of Puerarin from Kudzu Root Extracts

N-Glycan Profiling Analysis of a Monoclonal Antibody Using UHPLC/FLD/Q-TOF

Capillary GC Troubleshooting: a Practical Approach

Choosing the Right Calibration for the Agilent Bio SEC-3 Column

Size Exclusion Chromatography/ Mass Spectrometry Analysis of Antibody Drug Conjugates Using the Agilent 1260 Infinity II Bio-Inert LC

Using the Pulsed Flame Photometric Detector (PFPD) for Low-level Analysis of Organophosphorus Pesticides

Changing the Game in LC-MS/MS. New Tools for Unprecedented Performance in Residue Analysis. Dr. Thomas Glauner

Instructions for Capillary Electrophoresis Peptide Analysis Kit

Transcription:

Analysis of Degradation Products of Doxycycline in Solution Exposed to Light and Elevated Temperatures Using the Agilent 1 Infinity Series High Dynamic Range Diode Array Detector Impurity Analyzer System Application Note Small Molecule Pharmaceuticals & Generics Author A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany Abstract Tetracyclines undergo epimerization and degradation if stored under inappropriate conditions. Stability experiments, which are important for the deteration of the expiry date, were done using doxycycline. Doxycycline was exposed to light and elevated temperature for days. To detere decomposition products, the Agilent 1 Infinity Series HDR-DAD Impurity Analyzer System was used. Using this analyzer, it was possible to detect peaks with peak heights <.. DAD 1 6 mm 97 96 96.5 Percentage change for doxycycline 95 9 9.5 9.77 93.79 DAD Clustered DAD Area (%) 93 9 91 9.7169 9 3.7 mm 89 88 Peak at start 17 hours 3 hours 33 hours 5.5 days

Introduction Tetracyclines are antiobiotics used in case of bacterial infections. Typical applications are prophlylaxis and therapy of human and animal infections. They are also used in animal feed as a growth promoter. When exposed to heat and light, tetracyclines undergo epimerization and degradation. Often, the degradation products have very low antibiotic activity, and some are toxic 1,,3. In the pharmaceutical industry, stability tests must be done for all pharmaceutical products on the market. Recommendations from the International Conference on Harmonization (ICH) include long-term studies, where the product is stored at room temperature and humidity conditions. In further studies, the product was stored at more extreme conditions. Experimental Instrumentation Agilent 1 Infinity Series HDR-DAD Impurity Analyzer System: Agilent 19 Infinity DAD with 6 mm cell (G1A) (clustered) Agilent 19 Infinity DAD with 3.7 mm cell (G1A) (clustered) Agilent 1 Infinity HDR-DAD Kit (G199AA) Agilent 19 Infinity Thermostatted Column Compartment (G1316C) Agilent 19 Infinity Autosampler G6A Compound analyzed Doxycycline and impurities. Doxycycline was purchased from Sigma-Aldrich, Germany O HO HO O O NH HCl H H H C H H N(CH 3 ) Methacycline O HO HO O O CH 3 N(CH 3 ) Doxycycline hyclate NH HCl ½H O ½CH 3 CH The1 Infinity Series HDR-DAD Impurity Analyzer system offers the possibility to recognize degradation products at very low levels, due to the low noise behavior of this detector. In addition, the main compound can be analyzed within the same experiment due to the wide dynamic range of the system. In the following experiment, doxycycline was dissolved and the solution was exposed to light at C for several days. From time to time, the solution was analyzed to discover additional impurities and the changes in the main compound and impurities, which were present in the starting solution. Agilent 19 Infinity Thermostat (G133B) Agilent 19 Infinity Quaternary Pump (GA) Chromatographic conditions Parameter Value Column Agilent ZORBAX Eclipse XDB-C8, 3 1 mm, 3.5 µm (p/n 961967-3) HDR-DAD Flow rate Mobile phases Wavelength = 35, 5, 8 nm, reference = off, data rate = Hz.8 ml/ A=water, B=Acetonitrile, C=1%TFA in water Gradient at utes A = 65 %, B = 15 %, C = %, at 5 utes A = 37 %, B = 3 %, C= %, at 6 utes A = %, B=6 %, C= % Stop time Post time 6 utes 3 utes Column temperature C Injection volume 1 µl, C, needle wash for 3 seconds O HO HO O O CH 3 N(CH 3 ) 6-Epidoxycycline NH Sample preparation A mg sample of doxycycline was dissolved in 1.5 ml water/acn = 1:, 1-µL injection volume contained 13.33 µg of doxycycline. Acquisition and evaluation software Agilent OpenLAB CDS ChemStation Edition Rev.C.1.5

Results and Discussion The high dynamic range (HDR) system was configured during instrument configuration. Both detectors were clustered, and the delay volume of the capillary connecting both detectors was filled in. In the user interface, the clustered detectors appear as one detector (Figure 1). For the analysis of doxycycline, three wavelengths were selected: 3, 8, and 35 nm, to ensure discovery of all impurities. In the data file, all three HDR DAD signals were stored as well as the three signals of the 6-mm and the three signals of the 3.7-mm cell (Figure ). Having dissolved mg of doxycycline, the followings experiments were done: Figure 1. User interface in an Agilent OpenLAB CDS ChemStation. Clustered detectors Analysis of the fresh solution The solution was exposed to daylight at C for 17 hours and analyzed afterwards Analysis after 3 hours exposure Analysis after 33 hours exposure Analysis after 5.5 days exposure 8 6 DAD1 A, Sig = 3,1 DAD1 B, Sig = 35,1 DAD1 C, Sig = 8,1 LNG1 A, Sig = 3,1 LNG1 B, Sig = 35,1 LNG1 C, Sig = 8,1 SHT1 A, Sig = 3,1 SHT1 B, Sig = 35,1 SHT1 C, Sig = 8,1 Figure. Stored signals. DAD-HDR 6-mm cell 3.7-mm cell 1 3 5 3

One prerequisite for decomposition studies is that even very small decomposition peaks are detectable. Therefore, the noise level must be as low as possible. For the analysis of doxycycline, the P to P noise level was as low as.13 (Figure 3). This enabled the detection of peaks with a peak height below.. Figure shows chromatograms of the fresh and the exposed solution after 5.5 days. Impurities 1,, and 3 were present from the beginning. Visibility of Impurity started after 17 hours. 5.5 days and exposure to light at C, Impurities 5 to 13 were detected. 8 7 6 5 -. -. -.6 -.8 -.5 -.5 -.5 -.56 -.58.5 P to P noise~.13.9.96.98 1. 1. 1. 1.6 1.8 1.1 Peak height =.15 Doxycycline 3 1.5 1.5 1.51 1.751 1.959.191.33.391 1 -.5 1.6 1.8.. 1 3 5 Figure 3. Analysis of doxycycline and deteration of noise level. 1 1 1 8 7 6 6 5-3 1 Impurity 5 Impurity 6 Impurity 7 Impurity 8 Impurity 9 Impurity 1 1.5..5 3. 3.5 Impurity 1 Impurity Impurity Impurity 3 Analysis directly after dissolution Analysis after exposure to light at C for 5.5 days 1 1 1 8 6 - Impurity 11 Impurity 1 Impurity 13.3..5.6.7.8.9 5-1 1 3 5 Figure. Degradation of doxycycline after 5.5 days, overlay of start chromatogram and degradation chromatogram.

Figure 5 shows the process of degradation after 17 hours, 3 hours, 33 hours, and 5.5 days. 97 96 Percentage change for doxycycline The percentage of doxycycline decreased continuously, whereas Impurities 1 and increased. Impurity increased continuously, whereas Impurity 1 stagnated after the first increase. 17 hours, Impurity occurred and increased even further for the duration of the exposure. 5.5 days, additional small impurities became visible. Conclusion Area (%) 95 9 93 9 91 9 89 88 Peak at start 17 hours 3 hours 33 hours 5.5 days Stability tests are frequently done in the pharmaceutical industry to detere the date of expiry for a pharmaceutical product. To detect degradation products at trace levels, the Agilent 1 Infinity Series HDR-DAD Impurity Analyzer System was used for the decomposition process of doxycycline. Doxycycline was exposed to daylight at C over 5.5 days, and the degradation was monitored. It was possible to detect impurities with <. of peak height. 5.5 days of exposure, the percentage of doxycycline was reduced by 5.3 %, while additional impurities occurred and the amount of impurities already present in the original solution increased proportionally. Area (%).5 3.5 3.5 1.5 1.5.5. Percentage changes for impurites Impurity 1 Impurity Impurity 3 Impurity Additional small peaks after 5.5 days Peaks at start 17 hours 3 hours 33 hours 5.5 days Area %.15.1.5 Impurity 5 Impurity 6 Impurity 7 Impurity Impurity 9 Impurity 1 Impurity 11 Impurity 1 Impurity 13 Figure 5. Process of degradation. 5

References 1. R. Injac, V. Djordjevic-Milic, B. Srdjenovic Thermostability Testing and Degradation Profiles of Doxycycline in Bulk, Tablets, and Capsules by HPLC Journal of Chromatographic Science, Vol. 5 October (7).. L.A. Mitscher The Chemistry of the Tetracycline Antibiotics Medical Research Series, vol. 9. Marcel Dekker, New York, NY, p. 13 (1978). 3. Y. Liang, M.B. Denton, R.B. Bates Stability studies of tetracycline in methanol solution Journal of Chromatography A, 87: p.5 55 (1998).. HPLC and Pharmaceutical Stability Studies, Microbac Laboratories, Inc. (11) http://www.microbac.com/ uploads/technical%articles/pdf/ HPLC%and%Pharmaceutical% Stability%Studies.pdf, accessed February (1). www.agilent.com/chem This information is subject to change without notice. Agilent Technologies, Inc., 1 Published in the USA, March 1, 1 5991-EN