Indoor Air Quality Report

Similar documents
No dry drains/traps were found, eliminating a potentially concern for odors.

RESIDENTIAL MOLD ASSESSMENT. Final Report. Your Address Here

ANALYSIS OF FUNGI (MOLD) IN THE INDOOR ENVIRONMENTS BY DIRECT MICROSCOPIC EXAMINATION. (Analysis Code: FDE)

Improving Indoor Air Quality. Presented by Theo Cole, EIT

MOLD INSPECTION REPORT Block Home Inspections LLC

SUMMARY OF OUR FINDINGS

Airborne Mould Spore Assessment and Inspections

Post Remediation Warranty

Model Written Indoor Air Quality Program. The Summit Board of Education Administrative Offices 14 Beekman Terrace Summit, NJ

Premise Microbial Testing

ASHRAE and Indoor Air Quality

Outdoor Air Pollution. Primary vs. Secondary Air Pollutants

MOLD & FUNGI TECHNICAL BULLETIN

Indoor Air Quality Plan

IAQ Walkthrough. Jordan Elementary. J o r d a n P u b l i c S c h o o l s IEA, INC. Contact Us: Inspection Date:

Mold Remediation in Schools and Commercial Buildings

REQUIREMENTS FOR SUBSTANTIALLY DAMAGED AND SUBSTANTIALLY IMPROVED STRUCTURES

InterNACHI. Advanced Inspection of Crawlspaces for home inspectors

Storm Damage Assessment Report For: 1234 Example Street., Houston, TX 77002

Mold Report Writing

VERTEX Corporate Headquarters 400 Libbey Parkway Weymouth, MA p: f:

Analytical Service Code

Asbestos Inspection Cover Letter

DATE: October 31, TO: Toby Maxson, Principal. SUBJECT: Heritage ES - IAQ - Initial Contact - Room B-16

UNDER SECRETARY FOR HEALTH S INFORMATION LETTER MICROBIOLOGICAL ASSESSMENT OF PHARMACEUTICAL CLEANROOMS

Which indoor air pollutants raise concern? How can indoor air quality be determined?

HOW TO PERFORM MOLD INSPECTIONS

Evergreen Project Implementation Plan Instructions Low Income Housing Tax Credit Program

2001 National Workshop on State Building Energy Codes July th, 2001 Burlington, Vermont

breathe easier FILTRATION

Mold & Mold Safety Including Respiratory Protection

Test record CFU measurement. Test ID Site/Clinic Spijkenisse

TOXIC MOLD IS NOT THE PROBLEM by: Michael D. Geyer and Kenneth V. La Conde

R esearch Highlights. Moldy Houses: Why They Are and Why We Care & Additional Analysis of Wallaceburg Data: the Wallaceburg Health and Housing Studies

Construction Indoor Air Quality (IAQ) Management Plan

CITY S, CITY M AIR PURIFIERS. Clean air solutions

WOOD DESTROYING PESTS AND ORGANISM INSPECTION REPORT. Building No. Street City ZIP Date of Inspection Number of Pages

HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS

Homebuyers Survey. Final Report. Mr Client. A Home, A Street, A Town. 3rd July 2014

Quality of air is quality of life

ASSESSMENT OF BIOAEROSOL DISTRIBUTIONS IN MUNICIPAL SOLID WASTE TRANSFER STATION

Edouard AVANT GROVE U I C U I C. Modern Living Made Easy uichomes.com

STEP UP TO THE ENERGY STAR INDOOR AIR PACKAGE. A new opportunity for leading builders to create better environments inside and out

How To Stay Out Of Trouble When You See Or Suspect Mold. Steve Ransom - Certified Microbial Remediation Supervisor

Asbestos Consulting Radon Measurements Lead Assessments Indoor Air Quality Testing Mold Investigations. Project Number: Page 1 of 22

A MICROBIAL RESISTANCE EVALUATION OF INDOOR MATERIALS AIR KRETE INSULATION SAMPLE. prepared for AIR KRETE

AIR HYGIENE TEST SUITABLE FOR ALLERGIC PEOPLE

Thermal Imaging Inspection. Report Commissioned By:

** FREE ** Florida Mold Remediator License Exam Training Course

Moisture Management Plan

Common Household Contaminants: The Hazards and the Laws

Encapsulated, Sealed & Closed Crawlspace Installation Manual

Australian/New Zealand Standard

Limited Asbestos Demolition Survey

Asbestos Containing Materials Assessment 631 Fulton Avenue Spartanburg, South Carolina

Indoor Air Quality Program

Clean air solutions CITY M AIR PURIFIER

Lomanco, Inc. Crawlspace Protection Plan. available at: LO1807

Sewage Back-Ups: Information for Residents

Guidelines for Managing Mould and Dampness Related Public Health Risks in Buildings

Crothers Environmental Group, LLC

Truth in Sale of Housing Disclosure Report NOTICE - Read Entire Report Carefully. This is not a Buyer's Inspection!

CITY OF ORANGE BUILDING DIVISION 2016 Green Building Code Requirements For Residential Construction

Report of Microbial Growth Task Force

Property Condition Assessment

Indoor Building Survey and Product Inventory

Real-Time Microbial Detection... The Future of Mold, Bacteria and Water Damage Testing

Washington State Department of Health Division of Environmental Health

ASBESTOS INSPECTION REPORT Completed in accordance with 40 CFR, and (a)(4)

Subject: Flood Damage Remediation Date: 6/24/09 Revision: 01 Page 1 of 9 TABLE OF CONTENTS

Keep your home. FREE from DAMP, CONDENSATION and MOULD

Basement Renovation Guide For Residential Dwellings

Identification of indoor airborne microorganisms in residential rural houses of Uttarakhand, India

NCCEH Mould Investigation Toolkit Sample Checklists and Forms

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

Is Yours? Homes Across Missouri are Being Built to the Latest National Energy Efficiency Standards

Measuring Indoor Air Quality presented to AAFAME Members Nov. 14, 2017

3D Home Improvement and Inspection Services, Inc

Building Inspection Report

IAQ AND ENVIRONMENTAL HYGIENE ANALYSIS IN SUBDIVIDED UNITS IN HONG KONG

SELECT SURFACES LAMINATE FLOORING INSTALLATION GUIDE DRIFTWOOD

ADDENDUM NO.: 1 TO THE CONTRACT DOCUMENTS For SCC SWING SPACE FOR MOHR HALL MODERNIZATION (Existing Temps)

SEED WAREHOUSE & DISTRIBUTION CENTER AUDIT

Infrared Inspection Report

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

EPA s Lead Program Rule At-A-Glance

GENERAL IPM PHILOSOPHY AND PESTICIDE SAFETY

SECTION SUSTAINABLILITY CERTIFICATION REQUIREMENTS - GREEN GLOBES

Florida Energy Extension Service

Feel good to be in safe hands.

Test Report: Asbestos Analysis of Bulk Materials by PLM via the NY State ELAP Method

September 30, Ted Sherman Saint Paul Public Schools 1930 Como Avenue Saint Paul, MN Dear Ted,

General Specifications for HVAC System Cleaning

Foundation/Site Work Code Requirements

November 12, Mr. Derek Sandgren Helm Properties 1520 Butte House Road, Suite 400 Yuba City, California

CLASS I AND II ABATEMENT PROJECT SUBMITTALS

Crawl Space Moisture Control

TOWNSHIP OF LOGAN 125 MAIN STREET, PO BOX 314 BRIDGEPORT, NJ FAX

Transcription:

Indoor Air Quality Report Shawnee City Hall 222 N. Broadway, Shawnee, Oklahoma 74801

INDOOR AIR QUALITY SAMPLING REPORT Project Locations: Shawnee City Hall 222 N. Broadway, Shawnee, Oklahoma 74801 Prepared For: City of Shawnee/Human Resources Department Ms. Kelly Howard 16 W. 9 th. Street Shawnee, Oklahoma 74801 Prepared By: Wesley Anderson, CHMM, CIES, CMRS Environmental Solutions Specialists, Inc. 1401 Cornell Parkway Oklahoma City, OK 73108 405-949-5558 Sampling Date: February 5&13, 2009 Report Date: March 10, 2009

TABLE OF CONTENTS 1.0 EXECUTIVE SUMMARY...1 1.1 SCOPE OF WORK...1 1.2 SITE BACKGROUND...1 1.3 FINDINGS...2 1.3.1 Viable Fungi Results...2 1.3.2 Mycotoxin Sample Results...4 2.0 CONCLUSIONS...4 APPENDIX A Referances...5 APPENDIX B SITE MAP...5 APPENDIX C Biological Contaminants...5 APPENDIX D Laboratory Analytical Report...10 APPENDIX E - Disclaimer...11 APPENDIX F - Certifications...13

1.0 EXECUTIVE SUMMARY 1.1 Scope of Work Environmental Solutions Specialists, Inc. was retained by Ms. Kelly Howard, City of Shawnee/Human Resources Department, to conduct an Indoor Air Quality Investigation at Shawnee City Hall, 222 N. Broadway, Shawnee, Oklahoma. Environmental Solutions Specialists, Inc. (ESS) was contacted to determine if there is an air quality problem in the building due to mold, which can cause allergic reactions. On February 5 and 13, 2009, Wes Anderson, with ESS, collected ten indoor air samples to determine the air quality of the building as it relates to mold. All samples collected were submitted to EMSL Laboratories. Five samples that were collected utilizing an air pump with a PCR cassette were submitted for Trichothecene Mycotoxin analysis and five samples were collected utilizing an Anderson Sampler with an MEA Agar (Fungi) plate to determine if a viable (living) Stachybotrys fungus (mold) was present that is known to produce the Mycotoxin Trichothecene. 1.2 Site Background The Shawnee City Hall is a one story concrete block building with a basement located at 222 N. Broadway in Shawnee, Oklahoma. The building age is unknown, for this report. The Shawnee City Hall is occupied by the Town Clerk, administrative personnel, public works, and police department. The City Hall Basement is mainly utilized by the Shawnee Police Department. There was an historical pipe leak that occurred and impacted the Criminal Investigation Division (CID) Office and an area outside the hallway within the basement near the building elevators. The reason for the inspection involves an employee who has filed a workers compensation claim alleging exposure to Trichothecene Mycotoxin produced by a Stachybotrys fungi (mold). Several additional Indoor Air Quality Investigations were conducted by others to determine the same. The investigation conducted by ESS was in five areas, chosen by the client and based on previous investigations. These areas were the CID Office, Uniform Division Supervisor Office, Police Records and Information Hallway, Hallway Outside Room 116A, and First Floor Foyer (See Attached Building Layout).

1.3 Findings On February 5 and 13, 2009 site walks were conducted of the areas of concern. Those present during sampling were Ron Baze, Attorney representing Kent Borcherding, Matt Love, Attorney representing The City of Shawnee, and Wesley Anderson, with Environmental Solutions Specialists, Inc. On February 5, 2009 Wesley Anderson, with ESS, conducted one air sampling utilizing an air pump to draw a volume of air through a PCR cassette in each area. Approximately 50 liters of air volume was run across the sample media of the PCR cassette in order to collect particulate matter that may contain the Mycotoxin Trichothecene. In conjunction an Anderson Sampler was utilized with an MEA Agar (Fungi) plate to determine if any other viable (living) fungi (mold) was present that has the potential to produce other Mycotoxins, one air sample per area was conducted. Samples were submitted to EMSL Laboratories to the attention of Dr. Zeljko for analysis and identification. Dr. Zeljko reported that 50 liters of air was not enough air volume to collect a sufficient sample of debris (particulate) in the PCR cassette. Dr. Zeljko requested that a minimum of 1,000 liters of air would be needed in order to collect a large enough sampling of particulate in the PCR cassette. On February 13, 2009, Wes Anderson, with ESS, resampled the five areas utilizing an air pump and PCR Cassette to submit for Mycotoxin Analysis. Per Dr. Zeljko s recommendation 1,000 liters of air volume was ran through the PCR Cassette. No additional samples were collected for viable mold based on findings. All samples collected were submitted to EMSL Laboratories. Sampling was conducted during normal business hours for all air sampling, approximately 9:30 am to 12:30 pm. All samples collected were submitted to EMSL Laboratories to the attention of Dr. Zeljko for analysis and identification. Below are the results and in Appendix B, Laboratory Analysis. 1.3.1 Viable Fungi Results On February 5, 2009 Wesley Anderson, with ESS, conducted air sampling utilizing an Anderson Sampler with an MEA Agar (Fungi) plate to determine if any other viable (living) fungi (mold) was present that has the potential to produce other Mycotoxins, one air sample per area was conducted. Anderson Sampling device was set at 28.3 liters per minute for 5 minutes per location. Below are the results and in Appendix B, Laboratory Analysis.

Results of testing did not indicate the presences of Stachybotrys fungi at the time of testing. Aspergillus and Penicillium genera of fungi can produce Mycotoxins. * Mycotoxins are fungal metabolites that have been identified as toxic agents.

1.3.2 Mycotoxin Sample Results On February 13, 2009 Wesley Anderson, with ESS, conducted air sampling utilizing a calibrated air pump and a PCR Cassette to be submitted for Mycotoxin Analyisis Total Trichothecenes by ELISA. one air sample per area was conducted. The two Sampling devices utilized were set at 29 liters per minute and 25.5 liters per minute, run time approximately 35 minutes and 39 minutes. The total volume of air recorded per sample 1,000 liters. Below are the results and in Appendix B, Laboratory Analysis. Results of testing indicated Non Detect for Total Trichothecenes. * Mycotoxins are fungal metabolites that have been identified as toxic agents. 2.0 Conclusions At the time of sampling results of laboratory analysis of indoor air did not indicate the presence of Stachybotrys fungi or the presences of the Mycotoxin Trichothecene on the particulate matter collected in the areas of concern. Fungal identification did reveal the presence of Aspergillus and Penicillium genera of fungi which can produce Mycotoxins. But, these fungi are not associated with producing the Mycotoxin Trichothecene. Fungi colony counts for viable mold were higher in the Uniform Division Supervisor Office. It is possible this is due to at the time of sampling mold growth was observed on vegetable matter disposed of in trash can in the proximity of sampler.

APPENDIX A REFERANCES

Mold Remediation in Schools and Commercial Buildings, Indoor Environments Division (IED) of the U.S. Environmental Protection Agency (EPA) Bioaerosols: Assessment and Control, 1999 American Conference of Governmental Industrial Hygienists, 1999 Guidelines for the Assessment of Bioaerosols in the Indoor Environment, American Industrial Hygiene Association (AIHA) IICRC S520 Standard and Reference Guide for Professional Mold Remediation, The Institute of Inspection, Cleaning and Restoration Certification (IICRC), 2006

APPENDIX B SITE MAP

APPENDIX C BIOLOGICAL CONTAMINANTS

BIOLOGICAL CONTAMINANTS Biological contaminants include bacteria, molds, mildew, viruses, animal dander, house dust mites, cockroaches, and pollen. There are many sources of these pollutants. Some biological contaminants trigger allergic reactions, including hypersensitivity pneumonitis, allergic rhinitis, and some types of asthma. Molds and mildews release disease-causing toxins. Symptoms of health problems caused by biological pollutants include sneezing, watery eyes, coughing, shortness of breath, dizziness, lethargy, fever, and digestive problems. Allergic reactions occur only after repeated exposure to a specific biological allergen. However, that reaction may occur immediately upon re-exposure or after multiple exposures over time. As a result, people who have noticed only mild reactions or no reactions at all may suddenly find themselves very sensitive to particular allergens. Children, elderly people, and people with breathing problem, allergies, and lung diseases are particularly susceptible to disease-causing biological agents in the indoor air. TEN THINGS YOU SHOULD KNOW ABOUT MOLD 1. Potential health effects and symptoms associated with mold exposures include allergic reactions, asthma, and other respiratory complaints. 2. There is no practical way to eliminate all fungi and mold spores in indoor environment; the way to control indoor mold growth is to control moisture. 3. If mold is a problem in your building, you must clean up the mold and eliminate sources of moisture. 4. Fix the source of the water problem or leak to prevent mold growth. 5. Reduce indoor humidity (to 30-60%) to decrease mold growth by: venting bathrooms, dryers, and other moisture-generating sources to the outside; using air conditioners and dehumidifiers; increasing ventilation; and using exhaust fans whenever cooking, dishwashing, and cleaning. 6. Clean and dry any damp or wet building materials and furnishings within 24-48 hours to prevent mold growth. 7. Clean mold off hard surfaces with water and detergent, and dry completely. Absorbent materials such as ceiling tiles, those are moldy, need to be replaced. 8. Prevent condensation: Reduce the potential for condensation on cold surfaces (i.e., window, piping, exterior walls, roof, or floors) by adding insulation. 9. In areas where there is a perpetual moisture problem, do not install carpeting. 10. Molds can be found almost anywhere; they can grow on virtually any substance, providing moisture is present. There are molds that can grow on wood, paper, carpet, and foods.

APPENDIX D LABORATORY ANALYTICAL REPORT

EMSL Analytical, Inc. 107 Haddon Avenue, Westmont, NJ 08108 Phone: (856) 858-4800 Fax: (856) 858-0648 Email: westmontmicro@emsl.com Attn: Project: Wesley Anderson Environmental Solutions Specialists, Inc 1401 Cornell Parkway Suite 100 Oklahoma City, OK 73108 City of Shawnee Fax: (405) 858-0185 Phone: (405) 949-5558 Customer ID: ENSS78 Customer PO: ESS 09-101 EMSL Order: 370901138 EMSL Proj: Received: 02/06/2009 9:25 AM Analysis Date: 02/11/2009 Report Date: 02/11/2009 Viable Fungi Identification and Enumeration (Genus Level ID from Plate and Strip Impactors (EMSL Method M005)) 01 Sample Description 370901138-0001 02 370901138-0002 03 370901138-0003 04 370901138-0004 Location Volume (L) Media Incubation Temp (C) Sensitivity (CFU/m³) Fungal Identification Colony Count CFU/m³ CID Office 141.5 MEA 25 7 Bipolaris sp. 1 7 Sterile(dark) sp. 1 7 Total 2 14 Uniform Div/Super Ofc. 141.5 MEA 25 7 Acremonium sp. 2 14 Alternaria sp. 1 7 Bipolaris sp. 9 63 Cladosporium sp. 2 14 Penicillium sp. 1 7 Sterile(dark) sp. 3 21 Yeast sp. 1 7 Total 19 133 Police Records/Hall 141.5 MEA 25 7 Aspergillus sp. 1 7 Cladosporium sp. 3 21 Curvularia sp. 1 7 Sterile(dark) sp. 2 14 Total 7 49 Hall/Outside Rm 116A 141.5 MEA 25 7 None Detected 05 370901138-0005 First Fl/Foyer 141.5 MEA 25 7 Cladosporium sp. 2 14 Curvularia sp. 1 7 Sterile(white) sp. 1 7 Total 4 28 No discernable blank was submitted with this group of samples. Dennis Kinney, Ph.D. Laboratory Manager or other approved signatory Positive hole correction factors have not been applied to the reported data. EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. Interpretation of the data contained in this report is the responsibility of the client. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. Samples received in good condition unless otherwise noted. The detection limit is equal to 1 colony forming unit (CFU) per agar plate. ACCREDITATIONS: AIHA EMLAP #100194. ViableFungi THIS IS THE LAST PAGE OF THE REPORT. Page 1

APPENDIX E DISCLAIMER

LIMITATIONS This report was prepared in accordance with generally accepted standards of environmental practice(s) at time of this writing. This investigation was conducted solely for purposes of evaluating mold contamination at the subject property. Evaluations of conditions at this site were made from a limited number of observation points and conditions cannot be warranted at non-observation points. The Environmental Inspector has personally inspected the property, both inside and out and has made visual inspection of the property, to the extent possible by readily available access. The inspection does not include the moving of furniture or fixtures, or any type of inspection that would require extraordinary effort to access. Interpretations and conclusions made in this report that pertain to the mold are based solely on results of independent laboratory analyses of the samples taken at the property. Environmental Solutions Specialists, Inc. has no control over such testing and analyses and, therefore, disclaims any responsibility for errors or omissions arising therefrom. At present there are no strict numerical guidelines that are appropriate for assessing whether the contamination in an area is acceptable or not. Interpretations and conclusions derived from this report are based on a study from the University of Minnesota Mycological Aspects of Indoor Air Quality, Air and Waste Management Association Guidelines as well as information from the National Safety Council Environmental Health Center. Findings of this report are valid as of the date of the investigation. However, changes at this property, whether due to natural or man-made processes, may alter conditions. In addition, changes to applicable or appropriate standards may occur, whether resulting from legislation, new information, or other reasons. Accordingly, the findings of this report may be invalidated wholly or partially by changes outside Environmental Solutions Specialist s control. It is the intent of Environmental Solutions Specialists, Inc. to investigate contamination at this site according to the current data available for the purpose of protecting the property value of this site as well as the health and well being of individuals occupying the building. Environmental Solutions Specialists, Inc.

APPENDIX F CERTIFICATIONS