Inspections Unlimited 12:38 August 20, 2013 Page 1 of 23 Sampleweb2013.pt6

Similar documents
Property Inspection Report

Clients Name 123 Pleasant Valley Drive Any Town, OH 00000

G. Warren, Inc. Metuchen, NJ Definitions

Inspection Report. 1 of 8

Report exclusively for You!

Close-Up Home Inspection Home Inspection Report

Baltimore Home Specs LLC

Home Inspection Report

HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS

3D Home Improvement and Inspection Services, Inc

Sample Home Inspection

InterNACHI Home Inspection Report Checklist


Watson Home Inspection Services, LLC.

Page 3 of 12. Inspected Describe. Explained. Health & Safety. Maj. Def. Examiner Notes STRUCTURE N/A. Financial Impact. Impact.

Property Inspection Report

This report is general in nature and not technically exhaustive.

Collier Home Inspections, LLC

Pembridge The Country Club Collection TOWNHOMES AT CRYSTAL SPRINGS

Seal Harbor Development 1 Nagog Park Acton, MA 01720

Property Inspection Report

HOME INSPECTION REPORT

Davis Frame Co., Inc. Construction Budget Considerations

Features & Amenities. EXTERIOR FINISHES COMMUNITY FEATURES

Feasibility Report. Property Inspection Engineers, Inc. (248) Property Address. 405 Fairgrove Royal Oak, MI.

PROPERTY INSPECTION REPORT - Example

Edouard AVANT GROVE U I C U I C. Modern Living Made Easy uichomes.com

Home Inspection Report Report Number: For The Property Located On:

Property Condition Assessment

Home Inspection Report

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

Greater Dayton Home Inspections

A1-Inspections. Building Inspection Report. (Div of Canada Inc.) Inspection Date: Prepared For: Report Sample

Homes at Pine Ridge - NEW CONSTRUCTION SPECS

INSPECTION REPORT October 13, 2017

Typical Finished Basement Details

New Homes Starting at $124,900

Property Inspection Report

Inspection Report. Your Address. Prepared for: Sample Report Prepared by: Argosy Inspections 8244 SVL Box Victorville, CA 92395

Choice Home Inspection Services, Inc.

CHARTRES COURT Washington Avenue Houston, Texas ChartresCourtHouston.com CHARTRES COURT LLC

Quality Inspection 8618 London Heights San Antonio, TX Phone: (210)

RESIDENTIAL BUILDING REQUIREMENTS

Legacy Home Inspections

standard features Power Exhaust Fans w/light - Both Baths GFCI Receptacles Upgrade Light Fixture - Bath 1 Vanity - Per Lav GFCI Receptacles

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

Report. Inspection Date: 01/01/2000. Prepared For: John Q. Public. Prepared By: A1 Certified Home Inspections. Lake City, FL 32024

Post Office Box 867, Dunedin Florida Tel: (727) Fax: (727)

TOWNSHIP OF LOGAN 125 MAIN STREET, PO BOX 314 BRIDGEPORT, NJ FAX

First Choice Inspections

How's My House Home Inspections LLC

Integrity Home Inspection & Testing, LLC

RESIDENTIAL BUILDING PLAN REQUIREMENTS

CENTRAL GREAT PLAINS SERIES

This is an actual inspection report

Storm Damage Assessment Report For: 1234 Example Street., Houston, TX 77002

Premium Home Inspections. Inspection Report. Please read your report thoroughly!

BASEMENT FINISH CONSTRUCTION PLANS REFERENCE: 2015 INTERNATIONAL RESIDENTIAL CODE. PERMITS

Inspection Report. July 10, Sample Report. Property Address: 123 Main St. Any town Va Hallmark Residential Services, Inc.

My Home Was Built In What Can I Expect To See On My Report?

Qualifying Process for Handyman Online Qualifying Questions. Name: Street Address: City: State: Zip Code. Home Phone: Cell Phone: Address:

FLOORPLAN /ELEVATION SQ.FT. BDRM BATHS GARAGE BASE PRICE

New Homes Forestbrook Road. Yes, it s INCLUDED!

Abode Check Home Inspections

HOMES FOR SALE. Under Construction. Quality Stick Built Starting at $278,000. Watford City North Dakota WATFORDCITYREALESTATE.

HOME INSPECTION REPORT

Sample Pre-drywall Inspection Report

Client: Address: Property Description: (3) story townhouse Property age/ size: 2,781 s.f., built 2007 per listing Occupancy Status: Vacant

SUMMARY. Appliance: Corrective Action(s)

HOME INSPECTION REPORT

CONSTRUCTORA VARGAS NICARAGUA Building Inspection Las Delicias San Juan del Sur - Rivas Nicaragua

Presented by The National Association of Certified Home Inspectors Chicago Chapter

123 Main Street Anytown, IL 12345

CHECKLIST Inspecting a Garage

Your Company Name Goes Here. Your Company Name Goes Here

MOLD INSPECTION REPORT Block Home Inspections LLC

HOME INSPECTION REPORT

Material Report - [Trade Contractors] for plan: [E:\SoftPlan14\Projects\Sample Drawings.spf\2-Storey sqft.spf] Page 1 of 5

Truth in Sale of Housing Disclosure Report NOTICE - Read Entire Report Carefully. This is not a Buyer's Inspection!

The following is the Standards of Practice (SOP) for Home Inspectors required by the state of Florida.

The Inspection Process. Waxhaw N.C.

Applying for Permits to build a new house in Linn County

Page 1 of 17

CERTIFICATE of OCCUPANCY APPLICATION RESIDENTIAL

Building Inspection Report

Fairfax County, Virginia

Inspection Report. Date Inspected: 05/02/2017. Property Inspected: Main Street Anytown PA. Inspected by: Jeff Zimmerman, ASHI #259038

PROPERTY INSPECTION REPORT

Boise Home Inspection Report

KITCHEN REMODELS CITY OF MISSION VIEJO BUILDING SERVICES DIVISON 200 CIVIC CENTER, MISSION VIEJO, CA (949)

House2 Home Economy Inspection

REQUIREMENTS FOR SUBSTANTIALLY DAMAGED AND SUBSTANTIALLY IMPROVED STRUCTURES

PROPERTY INSPECTION REPORT

Building Inspection Report

COLONIAL PLANS. 708 North Street US Highway Route 1 Houlton, Maine (207)532,2444

Manchester III. Experience the Elegance of. 252 E. Elmhurst Ave. Elmhurst, IL. Elevation G

By: Ricci Construction Group Cheshire, CT

Highland Park. Exceptional Interiors (cont.) Green Technology. Designer Kitchen Features. Distinctive Exterior Features

FAIRA TRANSPARENCY REPORTS SW Fireside Ln, Oak Harbor, WA August 24, 2017

Standards of Practice for Building Inspections, recognized by the OACIQ

Transcription:

12:38 August 20, 2013 Page 1 of 23 Table of Contents General Information 2 Component Ratings 3 Roof Surface 4 Lots and Grounds 5 Exterior Surface and Components 7 Garage/Carport 8 Kitchen 8 Living Space 9 Fireplace/Wood Stove 10 Laundry Room/Area 10 Bathroom 11 Bedroom 12 Attic 13 Heating System 13 Air Conditioning 14 Electrical 14 Structure 15 Basement 16 Plumbing 17 Summary 18

12:38 August 20, 2013 Page 2 of 23 Property Address 123 USA St City Inspections State Ohio Zip 111111 Contact Name Paul Inspector Phone 216-571-1074 Fax Client Name Paul Inspector Client Address 12345 USA St City Inspections State Ohio Zip 111111 Phone 216-571-1074 Fax E-Mail inspectionsunlimited@cox.net Inspector Name Paul Wancata Company Name Inspections Unlimited Address 1535 Lourdes City Parma State Ohio Zip 44134 Phone 216-571-1074 Fax E-Mail inspectionsunlimited@cox.net File Number 2011-1000 Amount Received $285.00 General Information Property Information Client Information Inspection Company Conditions Others Present Buyer's Agent and Buyer Property Occupied Occupied Estimated Age 20 Years Old Entrance Faces North Inspection Date 04/03/2011 Start Time 10:00am End Time 1:00pm Electric On Yes Gas/Oil On Yes Water On Yes Temperature 75 Degrees Weather Partly cloudy Soil Conditions Dry Space Below Grade Basement Building Type Single family Garage Attached Sewage Disposal City How Verified Multiple Listing Service Water Source City How Verified Multiple Listing Service

12:38 August 20, 2013 Page 3 of 23 Component Ratings Ratings are based on visible components only at time of the inspection. Some system or component may be given two or more ratings in specific circumstances. It is always recommended to have any system or component that needs repair or replacement evaluated by a licensed or professional contractor. Satisfactory Marginal Safety Hazard System or component is functional with no visible defects. ************************************************************************* System or component is either of the following: A) Functional, but nearing the end of its expected life design. B) Functional, but is currently functioning beyond its expected life design C) Functional, but has visible signs of deterioration and and is not functioning at its full expected use. ************************************************************************* System or component is in unsafe condition due to it is either not present or does not meet safety standards. ************************************************************************ Repair / Replace (Major) System or component is broken, inoperable, or has visible deteriorating conditions which need repair or replacement consideration. Considered a major component. ************************************************************************* Repair / Replace (Minor) System or component is broken, inoperable, or has visible deteriorating conditions which need repair or replacement consideration. Considered a minor component. Partially Inspected Not Inspected ************************************************************************* Component was not completely visible, accessible, or operable at time of inspection and rating based on visible area only ************************************************************************* Component was unable to be inspected for safety reasons, lack of utility operation, inaccessible, disconnected at time of inspection, or beyond the scope of the inspection.

12:38 August 20, 2013 Page 4 of 23 Roof Surface Inspection of the roofing material and its components are not always completely visible or accessible due to weather conditions, height of structure, covered by other material, or may pose a safety hazard to the inspector. All efforts are made to make a complete evaluation of the roof and its applicable components. Determining its current age and expected future life expectancy is not always possible due to other contributing factors such as proper insulation, ventilation, and vegetation which may be negatively affecting roof material performance at the time of the inspection. Any future life expectancy is based on current aging symptoms identified at time of the inspection which are typical factors as recognized within the roofing industry. Main Roof Surface 1. Type: Gable 2. Method of Inspection: On roof 3. Unable to Inspect: 25% 4. Material: Asphalt shingle Repair / Replace (Major) Roof has deteriorating conditions and has reached the end of its useful life and should be budgeted for replacement. 5. Flashing: Aluminum Satisfactory 6. Valleys: Preformed metal Satisfactory 7. Skylights: Insulated glass Satisfactory 8. Plumbing Vents: PVC Satisfactory 9. Gutters: Aluminum Repair / Replace (Minor) Gutters are dirty and filled with debris which can cause overflow of gutters and send water down foundation wall. Recommend cleaning by a roofing specialist. 10. Downspouts/Extensions Aluminum Satisfactory Main Chimney

12:38 August 20, 2013 Page 5 of 23 Roof Surface (Continued) 11. Chimney: Brick Repair / Replace (Minor) Chimney requires tuck point repairs. Bricks material is cracked, popped, or broken surfaces. Recommend evaluation and repair by a mason contractor. 12. Flue/Flue Cap: Concrete Repair / Replace (Minor) Chimney cap cracked or deteriorated. Recommend evaluation and repair by a mason or chimney contractor. 13. Chimney Flashing: Metal Satisfactory Lots and Grounds Any negative grade towards a home can affect the foundation of a home and increase the likelihood of moisture intrusion into parts of the home below grade. it is always recommended to correct any negative grade situations. 1. Driveway Concrete Satisfactory 2. Walks: Concrete Satisfactory 3. Grading: Minor slope Repair / Replace (Minor) Grading is sloped towards foundation which can cause moisture intrusion down foundation. Recommend evaluation and repair by a professional. 4. Swale: Adequate slope Satisfactory

12:38 August 20, 2013 Page 6 of 23 Lots and Grounds (Continued) 5. Vegetation: Tall Trees Repair / Replace (Minor) Tree limbs over hang the roof and should be cut back 6. Patio: Concrete Satisfactory Steps / Stoop Attached Exterior Component 7. Attached to House? Yes Satisfactory 8. Railings Present? No Safety Hazard Handrails and balusters should be installed--this is a safety hazard and should be repaired immediately. 9. Steps Concrete Satisfactory 10. Walk Surface Concrete Satisfactory 11. Support Components Brick Repair / Replace (Minor) Tuck point repairs are needed. Recommend evaluation and repair by a mason contractor.

12:38 August 20, 2013 Page 7 of 23 Exterior Surface and Components Examination of the exterior walls are based on the visible components only. Decks & Porches are constructed many times close to the ground and their inspection of their structural components is not accessible or visible. Evaluation is based on any signs or symptoms indicating a possible problem. The exterior (VISIBLE) foundation walls are examined based on current conditions at time of the inspection. Foundation walls commonly develop settlement or shrinkage cracks and should be sealed and monitored for further movement. Cracks in foundation walls are evaluated based on the current conditions and any signs indicating possible structural issues. Inspections Unlimited does not guarantee future movement or structural integrity involving any cracks. Entire home Exterior Surface 1. Type: Aluminum siding Satisfactory 2. Trim: Aluminum Satisfactory 3. Fascia: Aluminum Satisfactory 4. Soffits: Aluminum Satisfactory 5. Foundation Wall: Block Satisfactory 6. Windows: Various styles Satisfactory 7. Basement Windows: Glass block Satisfactory 8. Door Bell Operative: Hard wired Satisfactory 9. Exterior Lighting: Surface mount Satisfactory 10. Exterior Electric Outlets: 110 VAC Repair / Replace (Minor) GFCI-All outside receptacles should be a GFCI receptacle or a GFCI circuit Recommend evaluation by an electrician. 11. Hose Bibs: Gate Satisfactory 12. Electrical Mast: Underground utilities Satisfactory 13. Gas Meter: Front of house--outside Satisfactory 14. Main Gas Valve: Located at gas meter Satisfactory Front Door 15. Entry Door: Steel Satisfactory 16. Storm Door Present Yes Satisfactory Back Door 17. Entry Door: Steel Satisfactory 18. Storm Door Present Yes Satisfactory

12:38 August 20, 2013 Page 8 of 23 Garage/Carport Main Garage 1. Type of Structure: Attached Yes Attached Garage Present 2. Garage Entry Door Metal Safety Hazard Door to home does not auto close which poses a safety hazard. Auto close hinges need to be installed. 3. Fire separation Drywall / plaster Satisfactory 4. Car Spaces: 2 5. Exterior Surface: Aluminum siding Satisfactory 6. Roof: Asphalt shingle Satisfactory 7. Gutters: Aluminum Satisfactory 8. Downspouts/Extensions Aluminum Satisfactory 9. Door Operation: Mechanized Satisfactory 10. Garage Door Metal Satisfactory 11. Door Opener: Lift Master Satisfactory 12. Garage Opener Receptacle 110 VAC Satisfactory 13. Roof Structure: 2x4 Truss Satisfactory 14. Service Doors: Metal Satisfactory 15. Ceiling: Drywall / plaster Satisfactory 16. Walls: Drywall / plaster Satisfactory 17. Floor/Foundation: Poured concrete Satisfactory 18. Electrical: 110 VAC Satisfactory 19. Windows: Vinyl double hung Satisfactory Kitchen Kitchen appliances are inspected for operation only at time of the inspection. Their future life and use are beyond the scope of the inspection. 1st Floor Kitchen 1. Ceiling: Drywall / plaster Satisfactory 2. Walls: Drywall / plaster Satisfactory 3. Floor: Linoleum Satisfactory 4. Windows: Vinyl double hung Satisfactory 5. HVAC Source: Heating system register Satisfactory 6. Electrical: 110v Repair / Replace (Minor) GFCI-All kitchen or bathroom receptacles within 6' of water should be a GFCI receptacle or on a GFCI circuit. Recommend evaluation and repair by a licensed electrician. 7. Sink: Stainless Steel Satisfactory 8. Faucet Chrome Satisfactory 9. Disposal: In-Sinkerator Satisfactory 10. Flow and Drainage Adequate Flow and drainage Satisfactory 11. Sink Plumbing PVC Satisfactory 12. Sink Base Cabinet Wood Satisfactory

12:38 August 20, 2013 Page 9 of 23 Kitchen (Continued) 13. Counter Tops: Formica Satisfactory 14. Cabinets: Wood Satisfactory 15. Appliances Present? No Living Space It is recommended to have a minimum of at least one smoke detector per floor of each home and in hallways to all bedrooms. A carbon monoxide detector is also recommended on each floor. Family Room Living Space 1. Ceiling: Drywall / plaster Satisfactory 2. Walls: Drywall / plaster Satisfactory 3. Floor: Carpet Satisfactory 4. Doors: Hollow wood Satisfactory 5. Windows: Vinyl double hung Satisfactory 6. Electrical: 110 VAC Satisfactory 7. HVAC Source: Heat system register Satisfactory Living Room Living Space 8. Ceiling: Drywall / plaster Satisfactory 9. Walls: Drywall / plaster Satisfactory 10. Floor: Carpet Satisfactory 11. Doors: Hollow wood Satisfactory 12. Windows: Vinyl double hung Satisfactory 13. Electrical: 110 VAC, light switch Satisfactory 14. HVAC Source: Heat system register Satisfactory Dining Room Living Space 15. Ceiling: Drywall / plaster Satisfactory 16. Walls: Drywall / plaster Satisfactory 17. Floor: Hardwood Satisfactory 18. Doors: Hollow wood Satisfactory 19. Windows: Vinyl double hung Satisfactory 20. Electrical: 110 VAC, light switch Satisfactory 21. HVAC Source: Heat system register Satisfactory

12:38 August 20, 2013 Page 10 of 23 Fireplace/Wood Stove For any fireplace, it is always recommended to have your fireplace cleaned and evaluated a minimum of at least once every two years based on usage. Operating the fireplace is beyond the scope of the inspection. Also, complete examination of the flue of the fireplace is usually not visible and should be evaluated by a chimney specialist. Family Room Fireplace 1. Fireplace Construction: Brick Satisfactory 2. Type: Wood burning 3. Fireplace Insert: Standard Satisfactory 4. Smoke Chamber: Brick Satisfactory 5. Flue: not visible Not Inspected 6. Damper: Metal Satisfactory 7. Hearth: Raised Satisfactory Laundry Room/Area Washer and dryer are inspected for operation only at time of the inspection. Their future life and operation is beyond the scope of the inspection. 1st Floor Laundry Room/Area 1. Walls: Drywall / plaster Satisfactory 2. Floor: Linoleum Satisfactory 3. Ceiling: Drywall / plaster Satisfactory 4. Doors: Hollow wood Satisfactory 5. Windows: Vinyl double hung Satisfactory 6. HVAC Source: Heat system register Satisfactory 7. Electrical: 110 VAC outlet, light switch Satisfactory 8. Laundry Tub: PVC Satisfactory 9. Laundry Tub Drain: PVC Satisfactory 10. Flow and Drainage Adequate Satisfactory 11. Washer Receptacle 110 VAC Satisfactory 12. Dryer Vent: Metal flex Satisfactory 13. Dryer Utility? Electric Satisfactory 14. Washer Drain: Wall mounted drain Satisfactory 15. Floor Drain: French drain Satisfactory

12:38 August 20, 2013 Page 11 of 23 Bathroom 1st floor main Bathroom 1. Ceiling: Drywall / plaster Satisfactory 2. Walls: Drywall / plaster Satisfactory 3. Floor: Linoleum Satisfactory 4. Doors: Hollow wood Satisfactory 5. Windows: Vinyl double hung Satisfactory 6. Ventilation: Electric fan Satisfactory 7. HVAC Source: Heat system register Satisfactory 8. Electrical: 110 VAC outlet, light switch Satisfactory 9. Counter/Cabinet: Wood Satisfactory 10. Sink/Basin: Molded single bowl Satisfactory 11. Flow and Drainage Adequate Satisfactory 12. Sink Plumbing PVC Satisfactory 13. Tub/Shower Fiberglass Satisfactory 14. Toilets: American Standard Satisfactory 1st floor half bath Bathroom 15. Ceiling: Drywall / plaster Satisfactory 16. Walls: Drywall / plaster Satisfactory 17. Floor: Linoleum Satisfactory 18. Doors: Hollow wood Satisfactory 19. Windows: Vinyl double hung Satisfactory 20. Ventilation: Electric fan Satisfactory 21. HVAC Source: Heat system register Satisfactory 22. Electrical: 110 VAC, light switch Satisfactory 23. Counter/Cabinet: Wood Satisfactory 24. Sink/Basin: Molded single bowl Satisfactory 25. Flow and Drainage Adequate Satisfactory 26. Sink Plumbing PVC Satisfactory 27. Toilets: American Standard Satisfactory

12:38 August 20, 2013 Page 12 of 23 Bedroom It is recommended to have a minimum of at least one smoke detector per floor of each home and in hallways to all bedrooms. A carbon monoxide detector is also recommended on each floor. 1st Floor Master Bedroom 1. Closet: Small & Walk-in Satisfactory 2. Ceiling: Drywall / plaster Satisfactory 3. Walls: Drywall / plaster Satisfactory 4. Floor: Carpet Satisfactory 5. Doors: Wood Satisfactory 6. Windows: Vinyl double hung Satisfactory 7. Electrical: 110 VAC Satisfactory 8. HVAC Source: Heat system register Satisfactory East Bedroom 9. Closet: Single Satisfactory 10. Ceiling: Drywall / plaster Satisfactory 11. Walls: Drywall / plaster Satisfactory 12. Floor: Carpet Satisfactory 13. Doors: Wood Satisfactory 14. Windows: Vinyl double hung Satisfactory 15. Electrical: 110 VAC Satisfactory 16. HVAC Source: Heat system register Satisfactory North Bedroom 17. Closet: Single Satisfactory 18. Ceiling: Drywall / plaster Satisfactory 19. Walls: Drywall / plaster Satisfactory 20. Floor: Carpet Satisfactory 21. Doors: Wood Satisfactory 22. Windows: Vinyl double hung Satisfactory 23. Electrical: 110 VAC Satisfactory 24. HVAC Source: Heat system register Satisfactory

12:38 August 20, 2013 Page 13 of 23 Attic 1. Attic Access? Yes Main Attic 2. Method of Inspection: In the attic 3. Unable to Inspect: 20% Satisfactory 4. Roof Framing: 2x4 Truss Satisfactory 5. Sheathing: Plywood Satisfactory 6. Ventilation: Gable Marginal Additional ventilation is needed to reduce condensation buildup in attic area. Recommend evaluation by a roofing contractor. 7. Insulation: Batts Marginal Insulation has visible signs of deterioration. Recommend additional insulation be installed, Recommend evaluation by an insulation contractor. 8. Insulation Depth: 8" Satisfactory 9. Vapor Barrier: not visible Not Inspected 10. Wiring/Lighting: 110 VAC Satisfactory 11. Moisture Penetration: none seen Satisfactory Heating System Evaluation of the heating system is a visual inspection of visible working components of the heating system. Dismantling of the furnace system to inspect all visual parts of the heat exchanger is beyond the scope of the inspection. It is recommended to have a certified technician to clean and evaluate your heating system on an annual basis. Basement Heating System 1. Manufacturer: Rheem 2. Model Number: 111111111 Serial Number: 111111111 3. Type: Forced air 4. Capacity: 105,000 btu 5. Area Served: Whole building 6. Approximate Age: 2 years old 7. Fuel Type: Natural gas 8. Heating System Operation: Adequate Satisfactory 9. Heat Exchanger: not visible Not Inspected The heat exchanger is not visible. However, there were no visible signs of any heat exchanger issues, including staining around the register vents, discolored flames or dancing flames from the combustion chamber when the blower motor came on. Also, there were no indications of 'CO' at any register vent or around the unit itself when running. 10. Unable to Inspect: 100% 11. Blower Fan/Filter: dd/disposable Satisfactory 12. Distribution: Metal duct Satisfactory 13. Draft Control: Automatic Satisfactory

12:38 August 20, 2013 Page 14 of 23 Heating System (Continued) 14. Flue Pipe: Double wall Satisfactory 15. Controls: Limit switch Satisfactory 16. Humidifier: April-Aire Satisfactory 17. Thermostats: Programmable Satisfactory 18. Suspected Asbestos: No Air Conditioning Due to manufacturer specifications, it is not recommended to test the air conditioning system if the outdoor temperature is below 60 degrees or was below 60 degrees the night before. All outdoor air conditioning condensing units should be on a level surface and not blocked on any side by anything that will reduce air flow to the unit including vegetation. Condenser fins should be kept clean and free of debris. It is recommended that a certified technician evaluate the unit on an annual basis. Attached above furnace AC System 1. Manufacturer: Rheem 2. Model Number: 222222 Serial Number: 222222 3. Area Served: Whole building 4. Approximate Age: 2 years old 5. Fuel Type: 120-240 VAC Temperature Differential: 15 Degrees 6. Type: Central A/C Capacity: Not listed 7. A/C System Operation: Functional Satisfactory 8. Condensate Removal: PVC Satisfactory 9. Exterior Unit: Pad mounted Satisfactory 10. Refrigerant Lines: High and low pressure Satisfactory 11. Electrical Disconnect: Breaker disconnect Satisfactory 12. Exposed Ductwork: Metal Satisfactory 13. Blower Fan/Filters: dd/disposable Satisfactory 14. Thermostats: Programmable Satisfactory Electrical Testing of the electrical receptacles and switches is not completely exhaustive. A representative number of receptacle and lighting switches are inspected only. Inspection of all electrical components is not a code inspection. However, recommendations made for either repair or replacement may involve updating any or all electrical components to modern day electrical standards in conjunction with current electrical codes. What may have been an acceptable practice when the dwelling was built may not meet modern day living needs or standards. 1. Service Entry Underground Satisfactory 2. Service Size Amps: 150 Satisfactory 3. Volts: 120-240 VAC 4. Service Wire Aluminum Satisfactory 5. Smoke Detectors: Hard wired Satisfactory Basement Electric Panel 6. Manufacturer: General Electric Satisfactory 7. Maximum Capacity: 150 Amps

12:38 August 20, 2013 Page 15 of 23 Electrical (Continued) 8. Main Breaker Size: 150 Amps Satisfactory 9. Is the panel bonded? Yes Satisfactory 10. Ground: Plumbing and rod in ground Satisfactory 11. Branch Wiring Type <Romex> 12. Panel Labeled? Yes Satisfactory 13. Open Knockouts? No Satisfactory 14. Wiring Clamped to Panel? Yes Satisfactory 15. Breakers (110V) Copper and Aluminum Safety Hazard Double taps are present at breakers. These circuits need to be moved to their own circuit breaker. This is a safety hazard and needs repair by a licensed electrician. 16. Breakers (220V) Copper and Aluminum Satisfactory 17. 120 Volt Wiring Copper Satisfactory 18. 240 VAC Wiring Copper Satisfactory 19. AFCI: Not present Not Inspected 20. GFCI: Not present Not Inspected Structure 1. Structure Type: Wood frame Satisfactory 2. Stairs/Handrails: Wood Satisfactory 3. Railings Wood Satisfactory 4. Slab Not Visible Not Inspected

12:38 August 20, 2013 Page 16 of 23 Basement Evaluation of the foundation walls are based on their VISIBLE portion only. The basement foundation walls are examined based on current conditions at time of the inspection. Foundation walls commonly develop settlement or shrinkage cracks and should be sealed and monitored for further movement. Cracks in foundation walls are evaluated based on the current conditions and any signs indicating possible structural issues. Inspections Unlimited does not guarantee future movement or structural integrity involving any cracks. Basement walls are below grade where it is possible to have areas of moisture intrusion. Evaluation for moisture issues are based upon any visual moisture staining, visible water, and use of a moisture meter at time of the inspection. Materials used for basement walls are porous and will generally indicate some level of moisture present. Inspections Unlimited does not guarantee future water issues in the basement. However, evaluations are made concerning components related to basement water issues including outside grading issues and problems with gutters and downspouts. Large amounts of water settling against basement foundation walls can cause hydrostatic pressure and cause foundation issues such as bowing walls and horizontal cracks. It is recommended to fix all grading issues and keep gutters and downspouts clean. 1. Stair Railings Present? Yes Satisfactory 2. Basement Steps Carpet Satisfactory 3. Unable to Inspect: 20% 4. Piers/Posts: Steel posts Satisfactory 5. Bearing Walls: Block Satisfactory 6. Beams: Steel I-Beam Satisfactory 7. Joists 2x10 Satisfactory 8. Subfloor: Plywood Satisfactory 9. Ceiling: Exposed framing Satisfactory 10. Walls: Block Satisfactory 11. Floor: Poured Satisfactory 12. Electrical: 110 VAC, light switch Satisfactory 13. HVAC Source: Heat system register Satisfactory 14. Moisture Location: Block walls Marginal There is visible moisture staining on walls. Moderated to high levels of moisture indicated by moisture meter. Grading issues need to be corrected. Gutters and downspout issues need to be corrected. Resolving current issues will help to alleviate moisture issues. However, to completely alleviate moisture concerns, a waterproofing contractor would need to evaluate. 15. Finished Basement Area? No Finished Basement

12:38 August 20, 2013 Page 17 of 23 Plumbing 1. Service Line: Copper Satisfactory 2. Main Water Shutoff: Basement Satisfactory 3. Water Lines: Copper Satisfactory 4. Drain Pipes: PVC Satisfactory 5. Cleanout Accessible Satisfactory 6. Vent Pipes: PVC Satisfactory, Partially Inspected 7. Gas Service Lines: Black pipe Satisfactory Utility Room Water Heater 8. Manufacturer: General Electric 9. Model Number: 333333 Serial Number: 333333333 10. Type: Natural gas 11. Capacity: 40 Gal. 12. Approximate Age: 14 Years Old 13. Area Served: Whole building 14. Water Heater Operation: Functional Marginal Unit functional, but is functioning beyond designed life expectancy and should be budgeted for replacement. 15. Gas Line Black pipe Satisfactory 16. Flue Pipe: Single wall Satisfactory 17. TPRV and Drain Tube: Copper Satisfactory

12:38 August 20, 2013 Page 18 of 23 Marginal Summary Attic 1. Main Attic Ventilation: Gable Additional ventilation is needed to reduce condensation buildup in attic area. Recommend evaluation by a roofing contractor. 2. Main Attic Insulation: Batts Insulation has visible signs of deterioration. Recommend additional insulation be installed, Recommend evaluation by an insulation contractor. Basement 3. Main Basement Moisture Location: Block walls There is visible moisture staining on walls. Moderated to high levels of moisture indicated by moisture meter. Grading issues need to be corrected. Gutters and downspout issues need to be corrected. Resolving current issues will help to alleviate moisture issues. However, to completely alleviate moisture concerns, a waterproofing contractor would need to evaluate. Plumbing 4. Utility Room Water Heater Water Heater Operation: Functional Unit functional, but is functioning beyond designed life expectancy and should be budgeted for replacement.

12:38 August 20, 2013 Page 19 of 23 Safety Hazard Summary Lots and Grounds 1. Steps / Stoop Attached Exterior Component Railings Present? No Handrails and balusters should be installed--this is a safety hazard and should be repaired immediately. Garage/Carport 2. Yes Attached Garage Present Garage Entry Door Metal Door to home does not auto close which poses a safety hazard. Auto close hinges need to be installed. Electrical 3. Basement Electric Panel Breakers (110V) Copper and Aluminum Double taps are present at breakers. These circuits need to be moved to their own circuit breaker. This is a safety hazard and needs repair by a licensed electrician.

12:38 August 20, 2013 Page 20 of 23 Repair / Replace (Major) Summary Roof Surface 1. Main Roof Surface Material: Asphalt shingle Roof has deteriorating conditions and has reached the end of its useful life and should be budgeted for replacement.

12:38 August 20, 2013 Page 21 of 23 Repair / Replace (Minor) Summary 1. Gutters: Aluminum Gutters are dirty and filled with debris which can cause overflow of gutters and send water down foundation wall. Recommend cleaning by a roofing specialist. 2. Main Chimney Chimney: Brick Chimney requires tuck point repairs. Bricks material is cracked, popped, or broken surfaces. Recommend evaluation and repair by a mason contractor. 3. Main Chimney Flue/Flue Cap: Concrete Chimney cap cracked or deteriorated. Recommend evaluation and repair by a mason or chimney contractor. Lots and Grounds 4. Grading: Minor slope Grading is sloped towards foundation which can cause moisture intrusion down foundation. Recommend evaluation and repair by a professional. 5. Vegetation: Tall Trees Tree limbs over hang the roof and should be cut back 6. Steps / Stoop Attached Exterior Component Support Components Brick Tuck point repairs are needed. Recommend evaluation and repair by a mason contractor. Exterior Surface and Components 7. Exterior Electric Outlets: 110 VAC GFCI-All outside receptacles should be a GFCI receptacle or a GFCI circuit Recommend evaluation by an electrician. Kitchen 8. 1st Floor Kitchen Electrical: 110v GFCI-All kitchen or bathroom receptacles within 6' of water should be a GFCI receptacle or on a GFCI circuit. Recommend evaluation and repair by a licensed electrician.

12:38 August 20, 2013 Page 22 of 23 Partially Inspected Summary 1. Vent Pipes: PVC Plumbing

12:38 August 20, 2013 Page 23 of 23 1. Family Room Fireplace Flue: not visible 2. Main Attic Vapor Barrier: not visible Not Inspected Summary Fireplace/Wood Stove Attic Heating System 3. Basement Heating System Heat Exchanger: not visible The heat exchanger is not visible. However, there were no visible signs of any heat exchanger issues, including staining around the register vents, discolored flames or dancing flames from the combustion chamber when the blower motor came on. Also, there were no indications of 'CO' at any register vent or around the unit itself when running. Electrical 4. Basement Electric Panel AFCI: Not present 5. Basement Electric Panel GFCI: Not present 6. Slab Not Visible Structure