ISOBUTANE GEOTHERMAL BINARY CYCLE SENSITIVITY ANALYSIS

Similar documents
Consider a simple ideal Rankine cycle with fixed turbine inlet conditions. What is the effect of lowering the condenser pressure on

Improvement of distillation column efficiency by integration with organic Rankine power generation cycle. Introduction

Lecture No.3. The Ideal Reheat Rankine Cycle

Multi-Variable Optimisation Of Wet Vapour Organic Rankine Cycles With Twin-Screw Expanders

Organic Rankine Cycles

A Design of the Organic Rankine Cycle for the Low Temperature Waste Heat

Performance Assessment of a Shell Tube Evaporator for a Model Organic Rankine Cycle for Use in Geothermal Power Plant

Efficiency improvement of steam power plants in Kuwait

Investigation of Separator Parameters in Kalina Cycle Systems

Comparison of micro gas turbine heat recovery systems using ORC and trans-critical CO 2 cycle focusing on off-design performance

Pinch Analysis for Power Plant: A Novel Approach for Increase in Efficiency

The Reduced Pumping Power Requirements from Increasing the Injection Well Fluid Density

PERFORMANCE ANALYSIS OF ORGANIC RANKINE CYCLES USING DIFFERENT WORKING FLUIDS

OUTCOME 2 TUTORIAL 2 STEADY FLOW PLANT

Design and Optimization of Kalina Cycle for Geothermal Energy in Kenya

Comparison of combined heat and power systems using an organic Rankine cycle and a low-temperature heat source

POWER RECOVERY IN FLOATING LNG REGASIFICATION PLANTS

Heat Integration Schematic

ORGANIC RANKINE CYCLE AS EFFICIENT ALTERNATIVE TO STEAM CYCLE FOR SMALL SCALE POWER GENERATION

Fluid Mechanics, Heat Transfer, Thermodynamics Design Project. Production of Ethylbenzene

WELLHEAD POWER PLANTS

20/06/2011 Seminar on Geothermal Exploitation Santiago de Chile

Fluid Mechanics, Heat Transfer, Thermodynamics Design Project. Production of Styrene

Solar-Geothermal Hybrid Cycle Analysis for Low Enthalpy Solar and Geothermal Resources

HYSYS WORKBOOK By: Eng. Ahmed Deyab Fares.

Fluid Mechanics, Heat Transfer, Fluid Mechanics Design Project. Production of Ethanol

EFFECT OF AMBIENT TEMPERATURE, GAS TURBINE INLET TEMPERATURE AND COMPRESSOR PRESSURE RATIO ON PERFORMANCE OF COMBINED CYCLE POWER PLANT

Fluid Mechanics, Heat Transfer, Thermodynamics. Design Project. Production of Ammonia

Exergy Analysis of Absorption Power Cycle Depending on Source Temperatures

5. Steam Turbine Performance

a. The power required to drive the compressor; b. The inlet and output pipe cross-sectional area. [Ans: kw, m 2 ] [3.34, R. K.

Alexander Rattner MEAM-402 HW 2

Thermodynamic Data. CO (g, 0 C, 1 atm) CO (g,100 C, 1 atm):

Thermodynamic Modeling of Binary Cycles Looking for Best Case Scenarios

MODELLING AND OPTIMIZATION OF POSSIBLE BOTTOMING UNITS FOR GENERAL SINGLE FLASH GEOTHERMAL POWER PLANTS

Feedwater Heaters (FWH)

THE CHOICE OF WORKING FLUID: (AND AN EFFICIENT TURBINE) Ennio Macchi Department of Energy - Politecnico di Milano

Exploitation of Low-Grade Heat in Site Utility Systems

Efficiency enhancement of the ocean thermal energy conversion system with a vapor vapor ejector

Heat Exchangers. Introduction. Classification of heat Exchangers

Secondary Systems: Steam System

Available online at ScienceDirect. Energy Procedia 49 (2014 ) SolarPACES 2013

Performance Analysis of Shell and Tube Heat Exchanger Using Miscible System

3. PROPOSALS OF SMALL SCALE BINARY GEOTHERMAL POWER PLANT WORKING IN THE POLISH LOWLAND CONDITIONS

Modeling of Electricity Generation Using Medium-Temperature Geothermal Resources in Greece

Analysis of zeotropic mixtures used in low-temperature solar Rankine cycles for power generation

pinch 70 C 70 C 4 We want to cool both the hot streams to the pinch temperature. The next step is to find the duty for the two heat exchangers:

White Rose Research Online URL for this paper: Version: Accepted Version

Transportation of Natural Gas-LPG Mixtures

BINARY POWER PLANT MODELLING AND SENSITIVITY ANALYSIS FOR ELECTRICITY GENERATION FROM AN ENHANCED GEOTHERMAL SYSTEM

Supercritical CO 2 Brayton Power Cycles Potential & Challenges

Low-Grade Waste Heat Recovery for Power Production using an Absorption-Rankine Cycle

Kalina & Organic Rankine Cycles: How to Choose the Best Expansion Turbine?

THERMODYNAMIC STUDIES ON ALTERNATE BINARY WORKING FLUID COMBINATIONS AND CONFIGURATIONS FOR A COMBINED POWER AND COOLING CYCLE

Rankine (steam) Cycle Cooling Options

Optimal design of geothermal power plants

MECHANICAL ENGINEERING THERMAL AND FLUID SYSTEMS STUDY PROBLEMS

ES Analysis of Performance of Direct Dry Cooling. for Organic Rankine Cycle Systems

Turboden Geothermal References in Bavaria: Technology, Drivers and Operation

STUDY ON EFFECTIVE PARAMETER OF THE TRIPLE-PRESSURE REHEAT COMBINED CYCLE PERFORMANCE

Design and Off-Design Analysis of an ORC Coupled with a Micro-Gas Turbine

Development and Case Study of a Geothermal Power Generation System

THERMODYNAMIC ANALYSIS OF ORGANIC RANKINE CYCLE USING LNG COLD ENERGY DEPENDING ON SOURCE TEMPERATURES

Performance of a Combined Organic Rankine Cycle and Vapor Compression Cycle for Heat Activated Cooling

ProSimPlus Library (Standard version + rate base option)

Geothermal Steam Turbines for Various Purposes

Combined cycle with detailed calculation of Cp in the HRSG

Investigation of New Low-GWP Refrigerants for Use in Two-Phase Evaporative Cooling of Electronics

VENTURI FLOW METER CALIBRATIONS SERIAL NUMBERS: , , , Prepared for. Imperial Flange and Fitting.

IOP Conference Series: Earth and Environmental Science PAPER OPEN ACCESS

ENERGY RECOVERY IMPROVEMENT USING ORGANIC RANKINE CYCLE AT COVANTA S HAVERHILL FACILITY

CONTROL VOLUME ANALYSIS USING ENERGY. By Ertanto Vetra

Revue des Energies Renouvelables Spécial ICT3-MENA Bou Ismail (2015) Numerical study of a single effect ejector-absorption cooling system

Steam balance optimisation strategies

Modeling, Simulation and Optimization of Energy Systems using Aspen Plus. Giovanni Manente University of Padova

K.S. Rawat 1, H. Khulve 2, A.K. Pratihar 3 1,3 Department of Mechanical Engineering, GBPUAT, Pantnagar , India

Exergetic and economic analysis of Kalina cycle for low temperature geothermal sources in Brazil

SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT B.Tech. [SEM IV (ME-41, 42,43 & 44)] QUIZ TEST-1 (Session: )

Qualitative Phase Behavior and Vapor Liquid Equilibrium Core

INTEGRAL EFFECT NON-LOCA TEST RESULTS FOR THE INTEGRAL TYPE REACTOR SMPART-P USING THE VISTA FACILITY

High-efficiency low LCOE combined cycles for sour gas oxy-combustion with CO[subscript 2] capture

Organic Rankine Cycle Configurations


CHAPTER 3 PERFORMANCE CRITERIA FOR CHP

MULTI-OBJECTIVE OPTIMIZATION OF TURBO-EXPANDER IN ORGANIC RANKINE CYCLE SYSTEM

CHAPTER 4 STEAM TURBINE and CYCLE HEAT BALANCE

ASME PTC Flow Measurement

R. A. Walter and S. W. Wilson

Conceptual Design of Nuclear CCHP Using Absorption Cycle

Comparison of Enhanced Organic Rankine Cycles for Geothermal Power Units

A thesis submitted for the degree of Doctor of Philosophy. Liang Li, M.Sc.

Conception of a Pulverized Coal Fired Power Plant with Carbon Capture around a Supercritical Carbon Dioxide Brayton Cycle

Energy Analysis of Supercritical Water and Ammonia (Kalina) Power Cycle

CO 2. transcritical refrigeration cycles: potential for exploiting waste heat recovery with variable operating conditions

Chapter Six{ TC "Chapter Six" \l 1 } System Simulation

High-Efficiency Thermodynamic Power Cycles for Concentrated Solar Power Systems

Exergy Analysis of a Power Plant in Abu Dhabi (UAE)

Study on Heat Exchange Characteristics for PHC Energy Piles

Sizing and parametric optimization of a waste heat to power plant based on Trans- ORC

Final Report for Chevron Vapor Recovery Unit Project

Transcription:

131 ISOBUTANE GEOTHERMAL BINARY CYCLE SENSITIVITY ANALYSIS K. Z.Iqbal, L. W. Fish, and K. E. Starling School of Chemical Engineering and Materials Science, The University of Oklahoma, Norman, Oklahoma Presented are sensitivity analysis calculations to determine operating conditions for an isobutane geothermal binary cycle. For the design basis and cost formulas used, it is found that a subcritical pressure cycle is lower in cost than a supercritical pressure cycle which has a higher thermodynamic efficiency. INTRODUCTION Presented herein is a summary of sensitivity analysis calculations for an isobutane geothermal binary cycle performed using a computer simulator described elsewhere (1). The geothermal binary cycle, for which a schematic diagram is also presented elsewhere (1), is a Rankine-type power cycle in which the working fluid receives thermal energy by heat transfer from the geothermal brine. Geothermal binary cycle thermodynamics, equipment design, costing, and simulation are summarized elsewhere (1, 2); more detailed information is presented in reports available from the National Technical Information Service (3, 4). Design Basis To focus attention on cycle operating conditions, a design basis with fixed working fluid composition, equipment parameters, resource temperature and net power output is used herein, although these fixed parameters also could be varied in sensitivity analysis. Based on preliminary sensitivity studies, the selected design basis consisted of the following conditions: isobutane was the working fluid; the heat exchangers were of the countercurrent flow shell-and-tube type with 1-inch outside diameter tubes and 1 13/32-inch triangular pitch (tube center-to-center spacing); the brine and cooling water velocities were 7 ft/sec; the working fluid shell side fouling factor was 0.0001; the brine and cooling water tube side fouling factors were 0.0005 (a value typically selected for pure water because the brine was assumed to be of low salinity and to have the properties of pure water); the cooling water condenser inlet and outlet temperatures were 80 F and 100 F; the brine inlet temperature was 400 F; the axial flow turbine had a specific speed of 80 and an isentropic efficiency of 0.86; the net power output was 25 MW; the well system contained an equal number of production and reinjection wells with 8-inch casings, depths of 3925 ft, and flow rates of 109 lb/sec; the well gathering system piping was 5000 ft long. Sensitivity Studies Sensitivity analysis calculations for cycle operating conditions were focused on turbine inlet and exit conditions and heat exchanger LMTD's (log mean temperature differences). These factors are affected by the simulator input data for the turbine inlet temperature and pressure and the approach temperatures for the brine heat exchanger and the condenser. A quantity referred to herein as the capital cost index is used for evaluation of the sensitivity of capital cost to variations in the parameters studied. The capital cost index is simply the ratio of the calculated capital cost to an arbitrarily defined design basis capital cost. On the basis of previous work on geothermal binary cycles, the turbine inlet pressure and temperature were initially chosen to be 500 psia and 380 F. It was observed that the brine heat exchanger and condenser heat transfer surface areas as well as the shell side and tube side pressure drops were much higher than expected. This was due mainly to the large amount of superheat at the brine heat exchanger outlet and condenser inlet. It was decided to begin sensitivity analysis for a supercritical cycle; hence, a higher turbine inlet pressure of 1000 psia was selected. To avoid excessive superheat at the condenser inlet, and to obtain a near maximum enthalpy Proc. Okla. Acad. Sci. 57: 131-137 (1977)

132

133

134

135

136 change through the turbine, a turbine inlet temperature of 325 F then was chosen. Brine Heat Exchanger LMTD Figure 1 shows a minimum capital cost index for a brine heat exchanger LMTD of 35 F. The LMTD for the brine heat exchanger was varied by adjusting the allowable approach temperature between the working fluid and brine at the brine exit. The parameter which critically affects the brine heat exchanger LMTD is the pinch point T. For this calculation, the minimum allowable pinch point T was kept at 10 F. The interesting thing to note is that as the brine heat exchanger allowable approach temperature is increased, the brine flow rate increases, the brine heat exchanger LMTD increases, and the brine heat exchanger required surface area decreases, as expected, whereas the condenser duty and surface area increase slightly with a corresponding increase in the cooling water flow rate. The condenser duty is increased because of the increase in working fluid flow rate needed to make up for the parasitic power due to the increase in brine pumping required. As the brine heat exchanger LMTD is increased, the major equipment total capital cost decreases, while the well capital cost increases. At small LMTD's equipment cost dominates, while at large LMTD's well cost dominates, as can be seen from the shape of the curves shown in Figure 1. From the general shape of Figure 1, it can be stated that the optimum brine heat exchanger LMTD lies between 30 F and 37 F for the conditions specified. Condenser LMTD Figure 2 shows the effect of varying the condenser LMTD on the capital cost index. The brine heat exchanger LMTD of 35 was used for these calculations, which indicate the optimum condenser LMTD to be between 22 and 26 F. As shown by the behavior represented in Figure 2, as condenser LMTD increases, the required condenser surface area decreases, and so does the major equipment capital cost; but the brine heat exchanger duty increases because of decreased thermal efficiency and the resulting increase in working fluid flow rate. Hence, an optimum condenser LMTD exists which balances these opposing cost factors. Turbine Outlet Vapor Mole Fraction The results of the analysis performed to determine the optimum vapor mole fraction at the turbine outlet are shown in Figure 3. Brine heat exchanger and condenser LMTD's of 35 F and 24 F were utilized for all the data points. The important points can be noted. (a) The cost suddenly increases with increasing vapor mole fraction at a vapor mole fraction of 1.0 (100% quality) even though the amount of superheat is not more than 0.1 F. (b) The capital cost index is almost constant for vapor mole fractions less than 1.0, which is probably because the decrease in turbine efficiency corresponding to the amount of liquid present at the turbine outline has not been accounted for in the calculations. The capital cost would increase with increased liquid at the turbine exit if the decrease in turbine efficiency were considered. (c) The brine heat exchanger and condenser surface areas decrease as the vapor mole fraction decreases; the brine flow rate also decreases. (d) The major equipment capital cost decreases as the amount of superheat is decreased. For vapor mole fractions less than 1.0, the cost starts increasing as the vapor mole fraction is further decreased. It was concluded that a vapor mole fraction between 0.99 and 1.0 is optimal. Turbine Inlet Pressure In the sensitivity calculations discussed above, a turbine inlet pressure of 1000 psia was utilized. In order to evaluate the effect of turbine inlet pressure on capital cost, calculations at a number of pressures were carried out (with the turbine inlet temperature chosen to achieve a saturated vapor condition at the turbine outlet). The resulting calculations indicated a turbine inlet condition of 500 psia and 271 F to be optimal for the isobutane cycle under these conditions. Figure 4 shows a plot of turbine inlet pressure versus capital cost index. The following points can be noted. (a) The capital cost index decreases almost linearly as the turbine inlet pressure is decreased (owing mainly to decreasing brine heat exchanger cost) down to a pressure of 500 psia. (b) The capital cost index suddenly jumps from 1.0 at 500 psia to 1.1 at 470 psia as the turbine inlet pressure is decreased below 500 psia. (c) The increase in the total plant cost below 500 psia is due mainly to the amount of superheat at the condenser

137 inlet, which in turn has the following effects. i) The brine heat exchanger duty, size and brine flow rate increase because of the decrease in cycle efficiency caused by superheat at the condenser inlet, resulting in a larger working fluid flow rate. The increase in working fluid flow rate increases the cooling water flow rate required. ii) The condenser cost increases because of the increase in the heat transfer surface area due to the desuperheating region. iii) The cooling water pumping requirements also increase because of the increased flow rate of cooling water, increasing the parasitic power requirement. CONCLUSIONS Sensitivity analysis calculations summarized herein demonstrate the use of a geothermal binary cycle simulator for determination of near optimal operating conditions for an isobutane cycle. For the case of a 400 F geothermal fluid resource, it is shown that for isobutane, which has a critical pressure of 529.1 psia, a subcritical pressure cycle with turbine inlet pressure of 500 psia is lower in capital cost than supercritical pressure cycles, which are known to yield more work per pound of brine (3). The simulator also can be utilized for sensitivity analysis of capital cost with respect to equipment parameters, geothermal fluid resource temperature, plant net power, and working fluid composition. In addition, the simulator can be used as a subprogram for an optimization executive program to determine optimal values of parameters of interest in geothermal binary cycle power plant design. The user should note, however, that the simulator is not intended for use as a detailed plant design program and that any information peculiar to a specific geothermal site would have to be incorporated into the algorithm. ACKNOWLEDGMENT This work was supported by the University of Oklahoma and the Energy Research and Development Administration, Contract No. E- (40-1) -4944. REFERENCES 1. K. Z. IQBAL, L. W. FISH, and K. E. STARLING, Proc. Okla. Acad. Sci. 57: 122-130 (1977). 2. K. Z. IQBAL, L. W. FISH, and K. E. STARLING, Proc. Okla. Acad. Sci. 56: 110-3 (1976). 3. K. E. STARLING, L. W. FISH, K. Z. IQBAL, and D. YIEH, Report ORO-4944-3, Resource Utilization Efficiency Improvement of Geothermal Binary Cycles-Phase I, prepared for the Energy Research and Development Administration, December 15, 1975 (available from the National Technical Information Service). 4. K. E. STARLING, L. W. FISH, H. H. WEST, D. W. JOHNSON, K. Z. IQBAL, C. O. LEE, and M. K. VASUDEVAN, Report ORO-4944-4, Resource Utilization Efficiency Improvement of Geothermal Binary Cycles-Phase I, prepared for the Energy Research and Development Administration, June 15, 1976 (available from the National Technical Information Service).