STRING THEORY: AN EXAMINATION OF THE PROPERTIES OF HIGH STRENGTH SUTURE MATERIALS

Similar documents
New creative textile construction using innovative braiding technology and materials

DEVELOPMENT OF ULTRA LIGHTWEIGHT HOIST ROPE OF TOWER CRANE FOR SUPER SKYSCRAPER


Endumax an ultra-strong thin film with a high modulus

WHITE PAPER Flex Life vs Flexibility

Reproducible evaluation of material properties. Static Testing Material response to constant loading

Product and. &AvailabilityG. Low Relaxation (LR) Strand. Proudly Australian Made. Effective From: August 2016 Applicable For: Australia

Can the world s strongest medical grade fiber help you to design your next device?

Predicting the Creep Lifetime of HMPE Mooring Rope Applications

One Surgeon. One Patient. FLH /11

Mechanical Behavior of Glass Fiber Reinforced Polymer Pultruded Composite Gratings

Histoacryl A revolution in mesh fixation

Technical brochure: Dyneema in marine and industrial applications.

In-plane testing of precast concrete wall panels with grouted sleeve

A PRODUCT FROM KANTAFLEX (INDIA) PVT LIMITED

INSPIRING ATHLETES AT THE

Axial Tensile Testing of Single Fibres

Merrimack and Suwannee ACSS/TW/HS285 Conductor Stress-Strain Tests. Southwire Company

Lab 4: Creep, Stress-Strain Response, and Stress Relaxation of Polymer Samples in Tensile Loading

ENGINEERING MATERIAL 100

UHPC Connection of Precast Bridge Deck

Bone Tissue Mechanics

Investigations of fracture process in concrete using X-ray micro-ct

10,000. Peak Connection Strength, lb/ft 8,000 6,000 4,000 2,000

WHEEL TRUCKING TEST FOR WELD OF U-SHAPED RIB AND DECK PLATE IN THE ORTHOTROPIC STEEL DECK. Susumu Inokuchi 1

KEVLAR* ARAMID, A NEW FIBRE REINFORCEMENT FOR CONVEYOR BELTING. B. Pulvermacher Du Pont de Nemours International SA, Geneva, Switzerland

Nanoindentation. Kathy Walsh, Ph.D. Frederick Seitz Materials Research Laboratory University of Illinois at Urbana-Champaign

Polyethylene for biogas plants

Experiment 4 - Testing of Materials in Tension

EXPERIMENTAL STUDY ON THE EFFECT OF TENSION FOR RUBBER BEARINGS

ERTALON Extruded Products

Tensile Testing BACKGROUND INFORMATION. Harper, A., and Nickels, K Queensland University of Technology.

Personnel Protection Vehicle Protection Structural Protection

FLI COPPER NICKEL-TITANIUM

FLI COPPER NICKEL-TITANIUM

Regupol CONSTRUCTION. Regupol BA. Heavy duty screed isolation. Regupol BA. Excellent impact performance.

Mechanical behaviors of molded pulp material

Concrete-filled fiber reinforced polymer tube-footing interaction in bending

James River Pulp Mill, Marathon, Ontario Geocell Case History

DETERMINATION OF FAILURE STRENGTH OF CURVED PLATE WELD JOINT USING FINITE ELEMENT ANALYSIS

An Experimental Investigation on Mechanical Behavior of Macro Synthetic Fiber Reinforced Concrete

Processing of High-Strength Polymer Fibers

ULTIMATE LOAD-CARRYING CAPACITY OF SELF-ANCHORED CONCRETE SUSPENSION BRIDGE

Metal-to-glass bonding properties of an acrylate adhesive (DELO GB368) and an ionoplast interlayer (SentryGlas) at 23, -20 and 60 C.

CHARACTERIZATION OF PHYSICAL AND MECHANICAL PROPERTIES OF RIGID POLYURETHANE FOAM

STRENGTH OF MATERIALS laboratory manual

Monday December 6, Session 4C: Sports Field Netting

PHYSICAL, MECHANICAL, AND DURABILITY CHARACTERIZATION OF CARBON FRP CABLE

Carbon Fiber Rigging, Yesterday, Today and the lessons learned along the way

Repetition: Adhesion Mechanisms

Finite Element Modelling of Unreinforced Masonry (URM) Wall with Openings: Studies in Australia

Pair Count Minimum Bend Radius Design Type Maximum Pulling Tension

MECHANICAL PROPERTIES OF TRIAXIAL BRAIDED CARBON/EPOXY COMPOSITES

Ceramics in Orthopaedic and Neurosurgery. B. Sonny Bal, MD MBA JD PhD University of Missouri-Columbia Amedica Corporation

Rules for Classification and Construction Ship Technology

Breaking Strength and Elongation of Pressure Sensitive Tapes

The 3 rd TSME International Conference on Mechanical Engineering October 2012, Chiang Rai

Update on CWR on Open Deck Bridges

Easy Rider Mooring. Design Assessment. For. Advanced Mooring Technology CONSTRUCTION. Authorised:

Dynamic Shear Rheometer: DSR

Progress report Material characterization and impact performance of Semi Impregnated Micro-Sandwich structures, SIMS

ME -215 ENGINEERING MATERIALS AND PROCESES

CHAPTER 11: PRESTRESSED CONCRETE

The strength of a material depends on its ability to sustain a load without undue deformation or failure.

Materials Engineering 272-C Fall 2001, Lectures 9 & 10. Introduction to Mechanical Properties of Metals

8th CONFERENCE on. DYNAMICAL SYSTEMS THEORY AND APPLICATIONS December 12-15, Łódź, Poland

Roll Forming of Advanced High- Strength Steels

Functional Assessment and Clinical Outcome

FRP FOR CONSTRUCTION IN JAPAN

A study of plastic plateau disappearance in stress-strain curve of annealed polypropylene films during stretching

MECHANICAL CHARACTERIZATION OF SANDWICH STRUCTURE COMPRISED OF GLASS FIBER REINFORCED CORE: PART 1

Tensile behavior of lignocellulosic fiber reinforced polymer composites: Part I piassava/epoxy

PB 250, PB 400 / SD 560x Resilient & ambient curing epoxy foam

Fluoroscopy units come in many different physical configurations but all consist of the main components shown in this slide.

Characterization of Titanium Alloy Friction Stir Butt-Welds TIMET 54M, ATI 425 and BOATI Standard Grain

Mechanical Properties of Materials

KENYA STANDARD KS 574:2017. Steel fabric for reinforcement of concrete Specification

FE MODELING OF CFRP STRENGTHENED CONCRETE BEAM EXPOSED TO CYCLIC TEMPERATURE, HUMIDITY AND SUSTAINED LOADING

Liquidmetal Alloys in Minimally Invasive Medical Devices

Lab Exercise #2: Tension Testing (Uniaxial Stress)

Interface Shear Stress of Hollow Core Slabs with Concrete Toppings

Advanced FEA Stress Analysis of Medical Instruments and Devices using Femap, NX Nastran and LS-DYNA

High Density Polyethylene (HDPE) As a Marine Material. Written by: Tobias Clarke

Electrical Insulating Tapes

1. INTRODUCTION. (a) Sand/ Fabric-coated (b) Sand-coated deformed. (c) Helical wrapped/ribbed Fig.1 FRP anchors with different outer surfaces

Technical Information (Revised ) TOYOBO CO., LTD.

Development and Investigation of Mechanical Properties of PEEK Fine Particles Reinforced UHMWPE Composites

CONFINEMENT EFFECT OF FRP AND TRANSVERSE STEEL ON RETROFITTING SQUARE CONCRETE COLUMNS

ECO INSTRUMENT (NS M)

FINE MECHANICAL TESTING AT OLEM /IMEX/ Evgeni Ivanov

FE Review Mechanics of Materials

Whitepaper: Precision Micro-Braiding for Implantable Devices

Determination of Failure Strength of Flat Plate Weld Joint Using Finite Element Analysis

O Coaxial/Fiber/Microduct Hybrid Buried Cable. Serves businesses in a new commercial serving area. Mitigates future cost of fiber installation

DuraCer. Ceramic Components. The Strong Choice In Ceramics

Transcription:

STRING THEORY: AN EXAMINATION OF THE PROPERTIES OF HIGH STRENGTH SUTURE MATERIALS A. Jhamb, J. Goldberg, W. Harper, A. Butler, P.J. Smitham, W.R. Walsh Surgical & Orthopaedic Research Laboratories University of New South Wales, Prince of Wales Hospital Sydney, Australia

Abstract The evolution of arthroscopic shoulder surgery has lead to advanced developments in instrumentation and equipment. Pivotal to successful surgery are the high strength sutures. With all claiming high strength, we aimed to assess biophysical properties of each material via light microscopy, scanning electron microscope and mechanical testing. Peak load and stiffness were assessed using a knot free length secured with friction loops distracted at 10 mm/min using a Bionix MTS 1000kN load/test cell. Results were analysed by SPSS for windows New packets of #2 sutures were provided by Arthrex (Fibrewire), Depuy/Mitek (Orthocord), Linvatec (HiFi), and Smith & Nephew (Ultrabraid) for examination Fibrewire contains a UHMWPE central core within a braided polyester sleeve while Orthocord, does not have a structurally significant central core, and Hifi and Ultrabraid contain no central core. Fibrewire has a mean twist angle (MTA) of 20 degrees while the other three have a MTA of 35 degrees. HiFi, Orthocord and Ultrabraid have a large initial toe region as the braiding aligns itself with the applied load and achieved maximum strength and stiffness after significant deformation. In contrast, the central core and tighter braiding pattern in Fibrewire resulted in a stiffer suture early in loading (P<0.05). Ultrabraid had the highest ultimate strength in tensile testing at 264N followed by Fibrewire 238N, then HiFi at 215N and Orthocord at 212N. Fibrewire was significantly stiffer than HiFi, Orthocord, and Ultrabraid in the first 50N of testing

All sutures provide strength well above those required for tissue repair on immediate testing. Our review of suture materials may provide more insight into the available sutures on the market. Further testing is required to interpret clinical implications including preloading and creep during knot tying.

Introduction Suture materials form an integral part of arthroscopic shoulder surgery. With many suture materials available on the market, all claiming high strength, it may be confusing and difficult to distinguish one from another, and certainly to decide on which is superior. These materials are non-absorbable making it critical we understand what we are implanting into a patient and the properties of these implants. Many studies exist on knot performance using different knots and traditional suture materials. Monofilament sutures can lead to dehiscence and clinical failure due to knot slippage and/or loop elongation at low applied loads (1). This study examined the tensile and morphologic properties of the new so-called high strength sutures. Shoulder surgery has evolved from open to minimally invasive arthroscopic surgery. Most forms of surgery rely on suture materials. First generation braided multifilament non-absorbable sutures (ethibond / ticron) provided a suitable implant for open surgery. These sutures are based predominantly on polyester. Newer arthroscopic equipment (both implantable anchors and knot pushers) places higher loads on the suture. The first generation sutures were a common point of failure. The newer second generation high strength sutures are based on ultrahigh molecular weight polyethylene. The commercial form of this product is known as Dyneema. Dyneema has been used in many forms outside of the medical industry. Its biomechanical properties have lead to the rapidly expanding use throughout the world. It is manufactured through a gel-spinning process. It

is capable of absorbing large amounts of energy and thus used in ballistics protection, from bullet-proof jackets to armored vehicles. Its strength is fifteen times stronger than steel yet is so light it floats on water, allowing its use in marine vessels. It has a high modulus of elasticity and is flexible. Its properties also include having superior wear and abrasion resistance. Second generation suture materials are composed of this Dyneema. Materials and Methods New samples of number 2 suture materials were opened and each examined straight from the packet. Materials were provided by Arthrex (Fibrewire), Depuy/Mitek (Orthocord), Linvatec (HiFi), and Smith & Nephew (Ultrabraid). Materials were characterized based on the macroscopic, microscopic, and electron microscopic appearances to define flaws and differences between materials. Each material was then loaded to failure (knot free) in tension. Load deformation curves were analysed for ultimate strength and stiffness. Macroscopic/Microscopic Appearance - Each material was examined under an Olympus stereozoom microscope both in transverse and longitudinal sections. Each was then photographed under x 4 and x 10 magnification. The photographs were then viewed in a windows picture viewer and the mean twist or mean braid angle measured (Fig 1) using an electronic goniometer. Cross-sections of each suture were also examined and photographed and the presence or lack of a central cord noted.(figure 2) Electron Microscopic Appearance Each material was sectioned and set in a liquid metal mould and photographed under an electron microscope under magnification of x 100, x 500 and x70 (transverse section only) (figure 3)

Tensile Load Testing Single strands of each material, knot-free, were loaded in tension to failure. A Bionix 858 MTS testing device with a 2 kn load cell was used to record load displacement curves. The material was secured using friction loops (3 wraps at each end) and then clamped past the friction loops so that no weakness could be created in the material with knots (Figure 4). The testing protocol used a constant 5cm length of material and was distracted to failure at a rate of 10mm/min. Results Macroscopic/Microscopic Appearance- Visually few differences could be detected except from each distinguishing colour. Fibrewire has a light blue appearance. Hi-Fi is predominantly white with a blue polydioxanone strand. Orthocord is purple and Ultrabraid is white. The color may affect its material properties as a higher percentage of polyethylene Dyneema may contribute to its overall strength. The main differences in longitudinal section lay in the mean twist angle. (see figure 2). The fibrewire had the lowest twist braiding angle of 20 degrees while the other 3 all showed similar angles of 35 degrees. Both Fibrewire and Orthrocord contain a central core in cross section. The Fibrewire has a true central polyethylene core. The Orthocord can be seen to contain bundles of polydioxanone filaments which are far weaker than polyethylene. Hifi and Ultrabraid have no central core in transverse sectioning.

Electron Microscopic Appearance All materials were quite similar under electron microscopy with minimal surface flaws in the filaments/materials themselves. Overall all 4 materials were clean of debris however orthocord showed most debris compared with the other 3. Tensile Load Testing Ultrabraid (UB) had the highest ultimate strength in tensile testing at 264N followed by Fibrewire (FW) 238N, then HiFi (HF) at 215N and Orthocord (OC) at 212N (Figure 5). FW was significantly stronger than OC but not UB or HF. UB was significantly stronger than both OC and HF. The overall stiffness showed Ultrabraid to have the maximum stiffness (Figure 6). However, examining individual load displacement curves for each substance (Figure 7) shows that fibrewire was initially stiffer over the first 20mm.If we therefore, exam only the first 50 N FW was significantly stiffer than the other substances (Figure 8). Discussion Significant differences in material composition and construction can explain the differences in the biomechanical properties of each material. It would seem that the two main differences are:- 1.) The central core and 2.) The mean twist angle. The central core (predominantly a UHMWPE core) as opposed to no core or a PDS core separate the materials. Fibrewire is the only material with a PE core. Orthocord contains a central core of PDS while HiFi and Ultrabraid have no central core.

The PDS does not add to the strength of the material and infact will reduce the strength as to create the same thickness of suture the PDS must take up the space the stronger dyneema would hold. The dyneema explains the ultimate strength of all four materials being so much stronger than the first generation sutures which were based on polyester. All four provide strength above 200N. Ultrabraid had the highest ultimate strength of 264N followed by Fibrewire (238.5N), HiFi (214.3N) and Orthocord (211.7N). From our assessment of loads applied during knot tying, it would appear that all have enough strength to tolerate these loads. Even though significant differences were present, clinically all would be suitable. Differing stiffness may have clinical implications. Fibrewire certainly provides a far stiffer material during loads <50N. And once loads are applied >50N the stiffness rises for all 4 with some differences. Clinically in low applied loads including pulling through tissue, different materials may be more suitable. For example, a stiffer material may actually cut through tissue rather while gathering slack as opposed to the less stiff tissue. This may have clinical implications in that perhaps younger tissue may be more suitable to a stiffer material and perhaps more frail tissue would be more suited to a less stiff material to take up the slack rather than cut through the tissue. The mean twist angle was lowest in the fibrewire (20degrees) while the other three had a similar angle of 35 degrees. This twist angle with the central core was responsible for the significantly stiffer properties of fibrewire.

The difference in color between materials may also affect the properties of the individual sutures, as a higher percentage of polyethylene Dyneema may contribute to its overall strength and this may explain any other differences between suture types. Overall the main differences in biomechanical properties can be explained by the microscopic analysis of structure. The lower twist angle and central dyneema core lead to a significantly stiffer material (FW) compared to the other three materials. All three have a strength well above those required during knot testing (peak loads in vitro approximated 115N). The pressure remaining in a closed knotted suture drops off by 90% from loads applied. These newer generation suture materials all provide a material suitable for arthroscopic surgery. Certain individual characteristics based on the surgeon s preference for feel may ultimately dictate preference, however this study shows all have adequate strength and the suture is no longer the weakest link in our interlinked system of surgical failure involving surgical factors, patient biology, and implants and materials. References 1. Li X, King M, MacDonald P Comparative study of knot performance and ease of manipulation of monofilament and braided sutures for arthroscopic applications. Knee Surg Sports Traumatol Arthrosc. 2004 Sep;12(5):448-52. Epub 2004 Apr 30.

20 35 Fibrewire Hi Fi 35 35 Orthocord Ultrabraid

Fibrewire Hi Fi Orthocord Ultrabraid

SEM HF x 100, x 500, x 70 SEM FW x 100, x 500, x 70

Peak Force:Single Strand

Force (N) 350 300 250 200 150 100 50 0 S u tu re M a te ria l Fibrewire Hi Fi O rthocord Ultrabraid Maximum Stiffness 20 N/mm 15 10 5 0 OrthoCord HiFi FiberWire UltraBraid OrthoCord < HiFi < Fiberwire = Ultrabraid P<0.05, P=0.383 Load Displacement Curve

N 400 300 200 Fiberwire HiFi OrthoCord Ultrabraid 100 0 0 10 20 30 40 50 60 mm Initial Stiffness Initial Stiffness N/mm 16 14 12 10 8 6 4 2 0 OrthoCord HiFi UltraBraid FiberWire Fiberwire > all others (P<0.05) Stiffness (N/mm) first 15mm of displacement

N 200 150 100 50 Fiberwire HiFi OrthoCord Ultrabraid 0 0 5 10 15 mm