Getting the Most from Your DNA Analysis from Purification to Downstream Analysis. Eric B. Vincent, Ph.D. February 2013

Similar documents
Technical Review. Real time PCR

Optimize Your qpcr and RT-qPCR Assays with Careful Planning and Design

Comparing the Agilent 2100 Bioanalyzer Performance to Traditional DNA Analysis Techniques

Introduction To Real-Time Quantitative PCR (qpcr)

Quantitative analysis of PCR fragments with the Agilent 2100 Bioanalyzer. Application Note. Odilo Mueller. Abstract

TECHNICAL BULLETIN. SeqPlex DNA Amplification Kit for use with high throughput sequencing technologies. Catalog Number SEQX Storage Temperature 20 C

Functional Genomics Research Stream. Research Meeting: June 19, 2012 SYBR Green qpcr, Research Update

P HENIX. PHENIX PCR Enzyme Guide Tools For Life Science Discovery RESEARCH PRODUCTS

qpcr Quantitative PCR or Real-time PCR Gives a measurement of PCR product at end of each cycle real time

Performance characteristics of the High Sensitivity DNA kit for the Agilent 2100 Bioanalyzer

ReliaPrep FFPE gdna Miniprep System

MMLV Reverse Transcriptase 1st-Strand cdna Synthesis Kit

Non-Organic-Based Isolation of Mammalian microrna using Norgen s microrna Purification Kit

mirna Purification from Plant Tissues: Corn, Soybean and Arabidopsis

Application Note. Genomics. Abstract. Authors. Kirill Gromadski Ruediger Salowsky Susanne Glueck Agilent Technologies Waldbronn, Germany

TruSeq ChIP Sample Preparation

Lecture Four. Molecular Approaches I: Nucleic Acids

Protocol for DNA extraction from FFPE Samples

TECHNICAL BULLETIN. GenElute mrna Miniprep Kit. Catalog MRN 10 MRN 70

DNA purification and analysis

Gene Expression Technology

Bauer Core Standard Protocol Title: Guidelines for Designing Real Time PCR Experiments Pages: 5 Revision: 1.1 Date: 4/15/04

Roche Molecular Biochemicals Technical Note No. LC 10/2000

Agilent s Mx3000P and Mx3005P

FastFire qpcr PreMix (Probe)

HiPer Gel Extraction Teaching Kit (Column Based)

TIANamp Soil DNA Kit. For isolation of genomic DNA from soil.

Molecular Cell Biology - Problem Drill 11: Recombinant DNA

User Manual. NGS Library qpcr Quantification Kit (Illumina compatible)

HiPer RT-PCR Teaching Kit

HiPer Real-Time PCR Teaching Kit

Bio Rad PCR Song Lyrics

Product Name : Simple mirna Detection Kit

User Guide. Full-Length cdna Amplification Kit. Catalog Numbers: 013 (TeloPrime Full-Length cdna Amplification Kit) 018 (TeloPrime PCR Add-on Kit)

Chromatrap 96 DNA Micro Elution Purification Kit

LightCycler 480 qpcr Tools. Meeting the Challenge of Your Research

Quantifiler Human DNA Quantification Kit Quantifiler Y Human Male DNA Quantification Kit

NEBNext. for Ion Torrent LIBRARY PREPARATION KITS

FFPE DNA Extraction kit

Brilliant II SYBR Green QPCR Master Mix

AmpliScribe T 7 Aminoallyl-RNA Transcription Kit

INTRODUCTION TO REVERSE TRANSCRIPTION PCR (RT-PCR) ABCF 2016 BecA-ILRI Hub, Nairobi 21 st September 2016 Roger Pelle Principal Scientist

KAPA HiFi Real-Time PCR Library Amplification Kit

Implementation of Automated Sample Quality Control in Whole Exome Sequencing

GeneCopoeia TM. All-in-One qpcr Mix For universal quantitative real-time PCR. User Manual

Introduction to Real-Time PCR: Basic Principles and Chemistries

USB HotStart-IT. for increased specificity and consistent results. PCR, qpcr and qrt-pcr

SuperScript IV Reverse Transcriptase as a better alternative to AMV-based enzymes

Maxwell RSC System. Next Generation Automated Purification and Quantitation

TIANamp Marine Animals DNA Kit

Description...1 Components...1 Storage... 1 Technical Information...1 Protocol...2 Examples using the kit...4 Troubleshooting...

Single Cell Genomics

Quantitative Real Time PCR USING SYBR GREEN

Tips DNA Sequencing (Revision Date: 09 July 2007)

DNA Genotyping from Human FFPE Samples Reliable and Reproducible

High Pure PCR Template Preparation Kit for preparation of 100 nucleic acid samples Cat. No

Freedom EVO - HSM Workstation

Synthetic Biology for

Absolute Human Telomere Length Quantification qpcr Assay Kit (AHTLQ) Catalog # reactions

Unzipping Genes MB563 HiPurA TM PCR Product and Gel Purification Combo Kit

MagListo 5M Nucleic Acid Extraction Kit MagListo Magnetic Separation Rack

PureSpin DNA Clean Up Kit

Diagnosis Sanger. Interpreting and Troubleshooting Chromatograms. Volume 1: Help! No Data! GENEWIZ Technical Support

Molecular characterization, detection & quantitation of biological products Purin Charoensuksai, PhD

Quant One Step RT-PCR Kit

XactEdit Cas9 Nuclease with NLS User Manual

PureLink Plant Total DNA Purification Kit

Sensitivity vs Specificity

qpcr Kit, DNA-free Product components 100 rxn 250 rxn Product description

TQ RXN 2X Q-PCR Master Mix (SYBR, no ROX) 1 ml x 2 TQ RXN 2X Q-PCR Master Mix (SYBR, no ROX) 1 ml x 5

BLOOD, PLASMA & SERUM SAMPLE PREPARATION

Preparing Samples for Digital Gene Expression-Tag Profiling with DpnII

Applications Note 161 March 2010

Lecture 8: Sequencing and SNP. Sept 15, 2006

Brilliant SYBR Green QPCR Master Mix

E.Z.N.A. Bacterial RNA Kit. R preps R preps

E.Z.N.A. Tissue RNA Kit. R preps R preps

Note: for laboratory research use only. RNA High-purity Total RNA Rapid Extraction Kit (Spin-column) Signalway Biotechnology

scgem Workflow Experimental Design Single cell DNA methylation primer design

DNA and RNA Clean-up Guide

SYBR Real-Time PCR Kit

PrimeScript RT Master Mix (Perfect Real Time)

ZR-96 DNA Sequencing Clean-up Kit Catalog Nos. D4052 & D4053

Procedure & Checklist - Preparing SMRTbell Libraries using PacBio Barcoded Universal Primers for Multiplex SMRT Sequencing

EXTRACTME Kits, Product Brochure

MgCl 2 (25 mm) 1.6 ml 1.6 ml 1.6 ml 1.6 ml

Computational Biology I LSM5191

TIANamp Yeast DNA Kit

Preparing Samples for Digital Gene Expression-Tag Profiling with NlaIII

MightyAmp DNA Polymerase Ver.3

1. COMPONENTS. PyroStart Fast PCR Master Mix (2X) (#K0211 for 250 reactions of 20µl) 2. STORAGE 3. DESCRIPTION

RNA Isolation and Technology Applications. Nadine Nassif Senior Research Scientist Promega Corporation

Amplicon Sequencing Template Preparation

Recent technology allow production of microarrays composed of 70-mers (essentially a hybrid of the two techniques)

T7-Based RNA Amplification Protocol (in progress)

One Step SYBR PrimeScript RT-PCR Kit II (Perfect Real Time)

ab ChIP Kit Magnetic One-Step

mmu-mir-200a-3p Real-time RT-PCR Detection and U6 Calibration Kit User Manual MyBioSource.com Catalog # MBS826230


Transcription:

Getting the Most from Your DNA Analysis from Purification to Downstream Analysis Eric B. Vincent, Ph.D. February 2013 1

Presentation Outline Genomic Analysis Purification Quantitation Qualification Analysis Methods Deoxyribonucleic Acid Key considerations at each step Ways to overcome major challenges 2

DNA Analysis Each Step Affects the Quality of the Final Data PCR Amplify Cloning Purify Quantify qpcr Whole Genome Sequencing Microarray 3

Downstream Assays Different Tools Based on Experimental Needs PCR qpcr Sequencing Arrays Cloning SNP Genotyping SNP detection SNP Detection Sanger Sequencing: Confirmation Identification Targeted regions/application STR Analysis (ID) Methylation Analysis Genotype Confirmation (KOs) Chromatin Immoprecipitation Methylation Analysis Mutation detection Pathogen identification Mutation Discovery De Novo Genome Sequencing Microbiome Research Chromatin Immoprecipitation Methylation Analysis Comparative Genomic Hybridization Loss of Heterozygosity Pathogen Identification 4

Downstream Applications Importance of Input DNA Characteristics PCR qpcr Sequencing Arrays Quantity of DNA + + ++ +++ +++ ++ Integrity of DNA +/- Depending on amplicon - Typically small amplicons More important with longer read technologies, but many providers assume large fragments Typically small fragments, but providers expect minimum fragment sizes Lack of Inhibitors ++ ++ +++ ++ Accurate Quantitation ++ +++ +++ +++ 5

Purification - Setting the Stage for Downstream Success 6

DNA Purification Technologies All Provide Advantages Depending on Specific Needs Manual Small automated 96 well manual Automated 7

Purification, Manual Low Investment and Scalability are Attractive Manual columns and scalable solution-based purification are attractive low-throughput options for standard or difficult samples Advantages Low initial investment vs. automation Flexibility in sample processing Lower price per prep Minimal set up time Reasons to Consider Other Options Greater throughput desired Time constraints Error reduction Many sample types supported: Blood, Tissue, FFPE, Plant 8

DNA Purification, Small Scale Automation Small Automated Systems Offer Major Benefits Small, dedicated purification instruments allow individuals to automate purification and increase productivity Advantages Minimal initial investment Frees time for other activities Fewer purification errors Increases sample throughput Reasons to Consider Other Options Not enough throughput to justify Even greater throughput desired Input sample volume incompatibility Maxwell 16: 5 minute setup 30-45 minutes to extract 1-16 samples 9

DNA Purification, Manual 96 Well Vacuum Purification Increases Sample Throughput Advantages Low initial investment High sample throughput Offers performance equal to spin columns Reasons to Consider Other Options 96 well processing can be tedious Desire to reduce errors Staff time has become rate limiting Greater throughput desired Input sample volume incompatibility The Wizard SV 96 Genomic system can isolate gdna from many sample types in less than 60 minutes 96 well manual 10

DNA Purification, Automated 96 Well Increases Laboratory Throughput and Lowers Costs Advantages Increases laboratory productivity Aids in sample tracking Increases consistency of results Can automate many activities Reasons to Consider Other Options High initial cost Not enough throughput to justify Automated 11

Automated Purification Reduces Errors by Removing Repetitive Manual Processes Process small samples in 96 well plates rapidly including sample transfer! Consistent Purification Regardless of Input Sample Volume No Cross-contamination is Observed Array male/female samples Extract gdna Amplify male target The ReliaPrep SV 96 HT gdna Isolation System can process 96 samples with no operator intervention No male DNA detected in female samples 12

DNA Purification Yield, Integrity & Purity are Critical to Success Key Challenges Purifying sufficient DNA from: Small samples Difficult samples Degraded samples DNA integrity Isolating pure DNA No enzyme inhibitors to affect downstream applications 13

DNA Purification Extraction of Quality DNA from FFPE Samples ReliaPrep FFPE Miniprep System Helps Preserve the Integrity of Your FFPE DNA More Sensitive qpcr Assays Amplification of Large Targets Genomic DNA purified from a single 10µm mouse brain section using either the ReliaPrep FFPE gdna Miniprep System or competitor kit 10µl purified gdna used as template in multiplex PCR (GoTaq Hot Start). Fragments ranging from 100-400bp detected. Maxwell 16: The same level of performance is available in an easy-to-use format 14

Quantitation - A Simple but Critical Step in DNA Analysis 15

DNA Quantitation and Quality Determination Important but Often Underappreciated UV Absorbance Spectrophotometer NanoDrop /NanoVue Fluorescent Dye-based Quantitation Plate Reader Hand-held Instruments Gel Electrophoresis Agarose Pulse Field Agarose Electrophoresis Agilent 2100 Bioanalyzer What information does each method give us What information does each method not give us What are the advantages and disadvantages of each method.. 16

UV Absorbance Spectroscopy Rapid Assessment of Concentration and Purity Spectrophotometers (various manufacturers) NanoDrop (Thermo Scientific) NanoVue (GE Healthcare) Measure nucleic acid: Concentration Purity 17

UV Absorbance Each Wavelength Measures Different Parameters Wavelength 260nm 280nm 230nm 320nm Measurement Amount of nucleic acid present in a sample A260nm of 1.0 = 50μg/ml for dsdna 40μg/ml for RNA 33μg/ml for ssdna Amount of protein present in a sample Amount of other contaminants present in a sample Amount of light scattering components present in a sample; used for background subtraction 18

Purity Determination by UV Absorbance Guanidine Thiocyanate Absorbs at 230nm Purity Measurement Acceptable Ratios A 260 /A 280 Generally 1.8 2.2 A 260 /A 230 Generally >1.7 EDTA, carbohydrates and phenol also absorb at 230nm* Pure DNA DNA with 0.01% Guanidine ITC A 260 /A 280 = 1.8 A 260 /A 230 = 2.2 A 260 /A 280 =1.88 A 260 /A 230 =1.16 *http://www.nanodrop.com/library/t009-nanodrop%201000-&-nanodrop%208000-nucleic-acid-purity-ratios.pdf 19

UV Absorbance - NanoDrop Measures Small Volumes with Good Sensitivity Features: Measures the absorbance of small volume samples 0.5 2μl of sample required 190nm 840nm wavelength range Wide detection range 2ng/μl minimum (DNA) 15,000ng/μl maximum (DNA) Measurements in less than 30 seconds No other reagents or accessories required 20

UV Absorbance NanoDrop An Easy to Use, Popular System Choose Read Type: DNA Read: Water Blank Sample Output: Spectra Table - Yields - Purity ratios - ABS readings 21

UV Absorbance Disadvantages Detects all Nucleic Acid with no specificity Lack of Specificity Cannot distinguish between dsdna, RNA or ssdna RNA contamination cannot be determined Overestimation of DNA concentration due to contaminants Many contaminants absorb at 260nm No information on integrity Nucleotides and small DNA fragments still contribute to the 260nm reading 22

Fluorescent Dye Quantification The Most Sensitive Approach Dye binds dsdna the resulting conformation shift produces in fluorescence when excited Fluorescence is directly proportional to the amount of dsdna in the sample Easy Protocol: Add, Mix, Measure Incubate at room temp for 5 minutes Higher signal = more DNA present Unbound dye does not fluoresce Low background increases sensitivity 504nm Excitation Emits @ 531nm Unbound dye 504nm X 23

Fluorescent Dye Assay Formats Assay in Tubes or Plates to Match Your Workflow 1. Dilute Dye to make working solution (1:200) 2. Prepare standards and unknown samples 3. Add dye to samples and standards incubate 4. Measure fluorescence 1:200 dilution 1xTE 1:200 dilution 1xTE The QuantiFluor dsdna System can be used in single tube as well as 96 well plate formats 24

Fluorescent Dye-based Quantification Wide Dynamic Range Quantitate from 50pg/ml to 1µg/ml with QuantiFluor dsdna System Low Concentration Standard Curve High Concentration Standard Curve The QuantiFluor dsdna System Provides sensitive quantitation of dsdna 25

Fluorescent Dye Quantitation Disadvantages No Information on Purity or Integrity Must create high or low concentration standards Does not detect ssdna; which can be problematic for some assays No information on purity Separate dye-based quantification systems are available for RNA and protein No information on integrity Fluorescent dyes are potentially hazardous 26

Gel Electrophoresis Most Common Analysis Method Agarose and sometimes acrylamide gel electrophoresis Nucleic acid fragments separated by size Fragments are visualized by staining with a fluorescent dye that binds DNA, commonly excited by a UV light - Ethidium Bromide, SYBR Green, SYBR Gold and Diamond Nucleic Acid Dyes Amount of DNA can be estimated - Estimate relative intensity of fluorescence compared to a standard(s) - Gel densitometry 27

Gel Electrophoresis Assess Integrity and RNA/oligo Contamination Qualitative Analysis DNA integrity (minimal smearing) Intact gdna may be: Viewed as a slow migrating band in standard agarose gels Separated on pulsed field gel apparatus designed to separate very large DNA molecules RNA contamination can sometimes be observed Marker Hela 293 Hela 293 1 x 10 6 1 x 10 5 1 x 10 4 - RNase + RNase 1 x 10 5 1 x 10 4 5 x 10 6 1 x 10 6 5 x 10 6 Marker 5 x 10 6 1 x 10 6 1 x 10 5 1 x 10 4 5 x 10 6 1 x 10 6 1 x 10 5 1 x 10 4 28

DNA Purification Methods Affect Final gdna Size Assessed by Gel Electrophoresis Similar gdna Size Estimation Using a 0.8% Agarose Gel ReliaPrep gdna Purification Precipitation Method Silica Column Method 23.1kb 9.4kb 6.6kb 4.4kb 2.3kb 2.0kb 29

DNA Purification Methods Affect Final gdna Size Assessed by Gel Electrophoresis 0.8% Agarose Gel CHEF Gel Reveals Greater Size Range 23.1kb 9.4kb 6.6kb 4.4kb ReliaPrep gdna Purification Precipitation Method Silica Column Method Expands to 350kb 300kb 250kb 200kb 150kb 100kb 50kb 23.1kb 9.4kb 6.6kb 4.4kb 2.3kb 2.0kb 2.3kb 2.0kb 30

Gel Electrophoresis Drawbacks and Alternatives to Ethidium Bromide Low cost, but requires significant amount of handling and time Typically requires a few nanograms of DNA Minimum detectable mass varies by stain SYBR Green II, SYBR Gold and Diamond dyes are more sensitive then ethidium bromide SYBR Green II, SYBR Gold, and Diamond dyes can be viewed as safer alternatives to ethidium bromide, a known carcinogen 31

Agilent 2100 Bioanalyzer Microfluidics to Analyze 1μl of Sample Uses microfluidics to analyze DNA, RNA, protein, and cells using sample specific chips Samples are combined with a fluorescent dye and added into wells in the chip Size separated by electrophoresis The samples are detected by fluorescence, and electropherograms & gel-like images are provided for sizing and quantification 1μl of sample is required 11-12 samples are run per chip Analysis is complete in 30-40 minutes 32

Agilent 2100 Bioanalyzer DNA Analysis High Sensitivity Fragment Analysis DNA Analysis Kits High Sensitivity DNA Kit - dsdna fragments from 50-7000bp (5-500 pg/µl) DNA 12000 - dsdna fragments from 100 to 12000bp (0.5-50 ng/µl) DNA 7500 Kit - dsdna fragments from 100 to 7500bp (0.5-50 ng/µl) DNA 1000 Kit - dsdna fragments from 25 to 1000bp (0.5-50 ng/µl) Information provided: Sizes of DNA fragments Concentration of each fragment Gel-like image 33

Agilent 2100 Bioanalyzer Disadvantages No Assessment of Purity and Limited Size Range Intact gdna will not be detected (may clog the chip) No Information on purity Does not detect contaminants High costs of instruments and consumables 34

Summary: Each Method Provides Different Information Data UV Spec Fluorescent Dye Agilent Bioanalyzer Gel Electrophoresis Concentration Y Y Qualitative Integrity N N Y - but only smaller sizes Y - but most resolution requires special apparatus Specificity N Y N but can view N but can view Presence of Inhibitors Cost Y N N N Instrument can be $$$ but no reagent cost Instrument and reagent Most expensive Low cost 35

DNA Analysis Methods Choose a Method that Best Matches Your Needs 36

DNA Analysis Methods Multiple Options Available Key questions to ask yourself: How many targets do I want to measure? Am I interested in whole genome analysis? Am I interested in identifying new mutations? Do I want information on target size, integrity? Do I want highly quantitative data or is qualitative assessment OK? PCR Amplify qpcr Whole Genome Sequencing Cloning Microarray 37

Southern Blot Provides Information on Fragment Size & Copy Number Fragment with restriction enzyme(s) Electrophoresis Transfer to membrane Hybridize with Probe Wash Detect Signal DNA sample Target DNA (size abundance) Advantages: Provides fragment size and can provide copy number May help identifying possible pseudogenes Disadvantages: Requires a lot of sample Time consuming Throughput 38

PCR A Basic Technique Enabling Many Types of Analysis Widely used laboratory tool More advanced methods are available Rapid and cost effective analysis and preparation of nucleic acids Genotyping mice and transgenic animals Cloning - elements for genetic study (creation of cassettes for reporter gene assays) Mouse Tail Genotyping with Two Taq Polymerases Promega GoTaq DNA Pol Mutation Detection AMP-FLP Competitor Taq DNA Pol http://www.promega.com/resources/articles/pubhub/enotes/gotaq-hot-start-polymerase-for-mouse-genotyping/ 39

Taq is Taq, Right? Enzyme Choice & Rxn Conditions Make a Difference! GoTaq Long PCR Master Mix Improved Results with a Specialized Enzyme Amplifying Targets up to 30kb Standard Taq (L) vs. GoTaq (r) DNA polymerase with different targets Improvement by Optimizing Conditions Annealing temperature Mg+ concentration PCR additives... 40

PCR Rapid but Requires Gel Analysis Advantages: Rapid analysis Inexpensive Relatively sensitive Sensitive Amplification of a gdna Target Disadvantages: Time consuming Throughput Requires gel analysis which is labor intensive 41

End-Point vs. Real-Time PCR Low vs. Highly Quantitative Analysis Linear Plateau End-Point PCR is detected in the variable plateau phase. Real-Time PCR can detect product in exponential phase allowing more precise quantitation. Exponential

qpcr Highly Quantitative and Sensitive Analysis Robust enzyme and buffer systems in GoTaq qpcr Systems enables sensitive detection of downstream targets Titration of Input DNA GoTaq qpcr Mastermix can provide earlier C q values compared to other qpcr mixes GoTaq qpcr master mix allows sensitive detection of targets down to one copy 43

Fluorescence Brighter Signal Produces More Sensitive Assays 44

qpcr Highly Sensitive Analysis of Limited Targets/Rxn Advantages: Sensitivity Highly quantitative measurements Some multiplexing is possible Wide Dynamic range Can be often used with degraded samples Disadvantages: Limited number of targets assessed per reaction 45

Microarrays Multiplex Fragment Detection DNA samples are labeled, probes on arrays are unlabeled One-color microarrays are also performed (Affymetrix arrays) Compare one array to another to determine differences between samples 46

Microarray Applications Well Suited for Structural Studies Comparative genomic hybridization (CGH): analysis of copy number changes Gene ID: can be used to rapidly ID unknown organisms Chromatin Immunoprecipitation: ID protein binding sites SNP detection: Can screen samples for millions of sites at a time Sample 1 (Cy3 labeled) Sample 2 (Cy5 labeled) Overlay 47

Microarrays Good Genomic Coverage but Low Sample Throughput Advantages: Can provide good coverage Can be quite flexible (if you can make your own arrays) Reasonable data analysis Disadvantages: Requires a lot of sample CGH cannot detect changes in small regions Time consuming Cost some technologies are expensive Low throughput acgh Profile of the IMR32 Neuroblastoma Cell Line http://upload.wikimedia.org/wikipedia/commons/thumb/1/15/acgh_profile_of_the_imr32_neuroblastoma_cell_line.svg/2000px- ACGH_profile_of_the_IMR32_neuroblastoma_cell_line.svg.png 48

Next-Gen Sequencing A New Gold Standard? Many methods, many applications, many considerations Several technologies exist and additional technologies are in development for large scale sequencing of genomes with many applications: SNP discovery Mutation discovery/detection Identity Methylation Ultimately, sequencing data is dependent on the integrity and quality of the starting material 49

Sequencing Library Prep Considerations While the DNA is fragmented in the first step in preparation, protocols assume certain degrees of intactness. Inhibitors of downstream enzymes can effect the production of libraries best to use a purification kit that provides pure, intact DNA Genomic DNA Purification Fragment DNA Repair Fragment Ends da Tail Fragment Ends Adapter Ligation Size Select / Gel Purify PCR Enrichment

Whole Genome Sequencing The Most Data per Experiment but at a High Cost Advantages Provides the most information in a single experiment Absolute quantitation of sequence changes Absolute quantitation of previously undiscovered genes Disadvantages Expensive Requires extensive bioinformatic support = $$$ Also requires large data storage capabilities 51

Summary Purify ReliaPrep FFPE gdna Miniprep System Wizard Genomic DNA Maxwell 16 Instrument and Kits Quantify QuantiFluor dsdna System GoTaq DNA Polymerase GoTaq Hot Start DNA Polymerase GoTaq Long PCR Master Mix PCR Amplify qpcr Whole Genome Sequencing GoTaq qpcr Master Mixes GoTaq qpcr Probe qpcr Master Mixes Cloning pgem T-Easy Vector Wizard SV Gel and PCR Clean up System Microarray 52

Thank You