Fibre optic cables CTC LSZH 1,2kN

Similar documents
Industrial LSZH Loose Tube, Gel-Free, Double-Jacket Cable

Detailed Specifications & Technical Data

FTTH Fiber Optical Cable

PHOTOVOLTAIC CABLES. Energy and Fiber Optical Cables for Solar Energy Systems.

ENERGY PROTOLON(SMK) LWL. (N)TSKCGEWOEU Medium Voltage Reeling Cable with integrated Fibre Optics

Single core conductor BETAtherm 145

Construction guideline

Armoured Instrumentation Cables to BS7917

The Company by Peter Bröckskes sen. an independent, middle sized company

O Coaxial/Fiber/Microduct Hybrid Buried Cable. Serves businesses in a new commercial serving area. Mitigates future cost of fiber installation

Industrial Harsh Environment Fiber Cables

Superastic Flex Cable 450 / 750V Exceeds all the specifications in its category.

Product Classification. Standards And Qualifications. Representative Image. General Specifications. Construction Materials

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0

FINOLEX FLAME RETARDANT (FR) PVC INSULATED INDUSTRIAL CABLES FINOLEX FLAME RETARDANT (FR) PVC INSULATED INDUSTRIAL CABLES - PROJECT PACKING

Safe, efficient cable protection with high performance polymers

PERFORMANCE SPECIFICATION SHEET

Cables for Railway Signalling Applications General Requirements

Technical Specification for Single Core 38/66kV TR-XLPE Insulated Underground Cable

Generic Requirements for Optical Fiber and Optical Fiber Cable

OPDISYS Fiber to the Home - Solution

Cables for Drag Chains

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

Heatshrink & Cable Repair Solutions

Pair Count Minimum Bend Radius Design Type Maximum Pulling Tension

Glass Reinforced Polyester Enclosures BPG. Glass Reinforced Polyester Enclosures

CONTENT. Robot cables. page. < The company < W - worldwide < Certifications < Clientele / supplier numbers... 6

Exel Tubes and Hollow Profiles. Your benefits

Cable junction boxes with intrinsic fire resistance and insulation integrity

SECTION WIRES AND CABLES

PLASTIC CONDUIT SYSTEMS 1 MADE FROM PVC 4 2 MADE FROM HALOGEN FREE RAW MATERIALS 18 3 WITH ANTIMICROBIAL PROTECTION 30 4 BURIED UNDERGROUND 42

Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072.

Section ARMORED MEDIUM VOLTAGE CABLES SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR

HEKAPLAST. PE-HD twin wall cable ducts and cable protection pipes for underground installation. Corrugated and Twin Wall Pipes of Plastics

Inside Wire. Wire & Cable. Category 6 Plus Plenum. Category 6 Plus Riser. PREMIER Category 6 CMP/CMR

ETA-07/0291 of 30/06/2014. European Technical Assessment. Draft. General Part. Technical Assessment Body issuing the. Instytut Techniki Budowlanej

Heat-Resistant Thin Optical Fiber for Sensing in High-Temperature Environments

SPECIALISTS FOR MEDIA AND TEMPERATURE

TABLE OF CONTENTS. productgroep 69

Fujikura PANDA fiber products and Basics of PM fibers

Economically Priced Insulation For Domestic Heating & Plumbing Economically priced insulation for domestic heating and plumbing

MATERIAL DATA SHEET TECHLITE WHITE ACOUSTICAL FOAM

Ceramic Ceramic No. of Lead/Wire Lead Allied RS order Dia Ø Length Wires Type Length Code code

BHUTAN TELECOM LIMITED

Fire systems Woertz Handels AG Edition september 2015

Cables at the core of building performance

GEONFLEX - GEONDUR. New double structured wall conduits (HDPE) for underground networks

Introduction. Railway Cables

Revision 1 RAM ELEVATORS. Elevator Electrical Planning Guide. RAM Manufacturing Ltd

FLAMABILITY TESTS FOR ELECTRICAL CABLES

ABOUT US. Unit II: Halol, Gujarat. (Semi conductive compounds) (HFFR Halogen Free Flame Retardant)

Shrink-Kon Thin Wall Heat Shrinkable Tubing

Cable Ties. Body Width (in./mm) Length (in./mm)

AESTUVER fire-protection mastic For the AESTUVER expansion joint M

Multi-faceted variety. Always in good shape.

PROForms. Specifications SECTION FIBERGLASS REINFORCED POLYMER (FRP) PULTRUDED PRODUCTS

CORTINAS HAWAINAS PVC

ENGLISH. 1metre 7/.02mm Teflon insulated twin twisted lead

Specifications: Ice point resistance: Fundamental interval (0 C to 100 C): 38.5Ω (nominal)

Expanded Beam Optical Termini

PRODUCT CATALOGUE. for gke Steri-Record and gke Clean-Record Chemical indicators, PCDs and accessories for cleaning and sterilization

Experience and a History in Construction Products

Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths

ENGLISH Datasheet Platinum Resistance Pt100 & Pt1000 Thin Film Detectors Platinum Sensing Resistors Thin Film (Pt100 & Pt1000 Ohm)

insulate Seal Protect Single Wall ProductS

Cable solutions for Automation & Drives

ENGLISH Datasheet JIS Miniature Thermocouple Connector PCB Mounting Socket Types K, J, T, E, R/S & B (JIS Colour Code)

Low Smoke Zero Halogen (LSZH) Cables. The cable you can trust with the service you deserve!

ENGLISH Datasheet JIS Miniature Thermocouple Connector In-Line Plugs Types K, J, T, E, R/S & B (JIS Colour Code)

Custom-Designed Clamps. Machined Versions. Online Configurator for Custom-Designed Clamps A56.

IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor

AS... UV FIBERS AS... IR FIBERS GRADED INDEX FIBERS PCS - FIBERS HPCS - FIBERS SINGLE-MODE FIBERS CAPILLARIES

reusable food approved sterilisable strong and durable good rupture and tear resistance cutting die cutting welding bonding sterilising recycling

A-5 CABLE TECHNOLOGIES

DETAIL SPECIFICATION SHEET CABLE, ELECTRICAL, -20 C TO +105 C, 1000 VOLTS, TYPE LSFSGU

ULTRAMID VISION The first semi-transparent polyamide VISION

FDM Material Properties

Under Tile Heating Mat Installation Instructions

FP30112WHITE100 Heat Shrink TW Tubing 100' Spool

High-Tech Copper Products for Solar Systems

*** Supercedes: BECO E and COM , , & ***

Specialty Multimode Graded-Index Fiber

CONDUIT SYSTEMS FOR ELECTRICAL WIRES AND CABLES: ANACONDA CONDUIT AND FITTINGS FOR HYGIENIC DESIGN

Heat-Shrinkable Tubing

Versatile & High Performance LED

Spark and spatter. Sparks and spatter cause risk of fire and damage. Cepro welding blankets and grinding curtains offer secure separation.

Pallet Safe: Installation Supplement Rev

Electrical Insulating Tapes

Datasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths

INTERNATIONAL STANDARD

FrelTec GmbH. SMD Shielded Power Inductors

MT SUPERTUBE LS0H EMI SCREENED CONDUIT UK OWNED UK MANUFACTURER

ESTO Quality Guide for Landscaping Turfs Edition

Screw Cap Micro Tubes

Qualification Reference: AA/ Cage Code: MIL-C Cables NEMA WC27500 Part Number Builder

Magnetic float switch For vertical installation Model FLS for nuclear power plants

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

ERTALON Extruded Products

Tubes et tuyaux techniques Polígono Indutrial O Rebullón s/n Mos - España -

Transcription:

CTC LSZH,kN CTC LSZH,kN - Universal, Metallfree, Central Tube Cable. Light-weight, non-metallic, universal central tube cable (indoor/outdoor) with small diameter, rodent protected, longitudinal water-protected, with Low Smoke Zero Halogen outersheath. Installation: by blowing or pulling, into conduits or on cable trays. Characteristics Properties Unit Product group Universal cables Series Type Glasvezelkabel Single Mode CTC LSZH,kN Test procedures IEC 6079-- Application Strain relief Optical Element Fibre type Optical fibre standard Material outer sheath Colour outer sheath Halogen free (acc. EN 5067--) Inside/outside Loose tube, gel filled Single mode ITU-T G.657.A LSZH Article dependant, see detail sheet Flame retardant Acc. IEC 60-- UV resistant Cable metal free Longitudinal water blocking Radial water blocking Installation temperature -0 / 50 C Operation temperature range -0 / 70 C Transportation and storage temperature -0 / 70 C Attenuation @ 0 nm 0.6 db/km Attenuation @ 550 nm 0. db/km Attenuation @ 65 nm 0. db/km Construction and Colour codes No zie bijlagen Partnumber Description Outer diameter approx. (mm) Net weight (Kg/km) radius after radius during short term (Tm) (N) Long Term (Tl) (N) 75050 x SM G.657.A 7 50 05 0 600 800 Page /

CTC LSZH,kN Partnumber Description Outer diameter approx. (mm) Net weight (Kg/km) radius after radius during short term (Tm) (N) Long Term (Tl) (N) 7506 6x SM G.657.A 7 5 05 0 600 800 7505 8x SM G.657.A 7 50 05 0 600 800 7505 x SM G.657.A 7 50 05 0 600 800 7505 x SM G.657.A 7,6 59 5 50 600 800 Copyright (c) TKF, -0-0 Page /

Product information Cable construction and colour code CTC LSZH FO cable with central tube Indoor/Outdoor application Description: Optical fibres Central tube with,, 6, 8,, 6 or fibres Reinforcement of glass yarns Outer sheath (LSZH) Standard Colours: Fibrenr. Group Fibrenr. Red Green Blue 5 Yellow 6 5 White 7 6 Grey 8 7 Brown 9 8 Violet 0 9 Turquoise 0 Black Orange Pink Group Red +t Green +t Blue +t Yellow +t White +t Grey +t Brown +t Violet +t Turquoise +t Natural Orange +t Pink +t note +t: indicates a black tracer Version : PM-M05J Subject to technical alterations Page / This data sheet is put together with great care. Nevertheless we can not give any guarantees regarding the completeness, correctness or actualization of the information. No rights can be derived from the information as shown. TKF is entitled to modify this data sheet at all times with immediate effect due to (for example) changes in legislation. TKF can not be held responsible for the content of this data sheet or the consequences of using the information including incorrect translation of the information by third parties.

CTC LSZH,5kN CTC LSZH,5kN - Universal, Metallfree, Central Tube Cable. Light-weight, non-metallic, universal central tube cable (indoor/outdoor) with small diameter, rodent protected, longitudinal water-protected, with high pulling force and with Low Smoke Zero Halogen outersheath. Installation: by blowing or pulling, into conduits or on cable trays. Characteristics Properties Unit Product group Universal cables Series Type Glasvezelkabel Single Mode CTC LSZH,5kN Test procedures IEC 6079-- Application Strain relief Optical Element Fibre type Optical fibre standard Material outer sheath Colour outer sheath Halogen free (acc. EN 5067--) Inside/outside Loose tube, gel filled Single mode ITU-T G.657.A LSZH Black Flame retardant Acc. IEC 60-- UV resistant Cable metal free Longitudinal water blocking Radial water blocking Installation temperature -0 / 50 C Operation temperature range -0 / 70 C Transportation and storage temperature -0 / 70 C Attenuation @ 0 nm 0.6 db/km Attenuation @ 550 nm 0. db/km Attenuation @ 65 nm 0. db/km Construction and Colour codes No zie bijlagen Partnumber Description Outer diameter approx. (mm) Net weight (Kg/km) radius after radius during short term (Tm) (N) Long Term (Tl) (N) 75069 x SM G.657.A 7,9 68 5 80 500 500 Page /

CTC LSZH,5kN Partnumber Description Outer diameter approx. (mm) Net weight (Kg/km) radius after radius during short term (Tm) (N) Long Term (Tl) (N) 75070 6x SM G.657.A 7,9 68 5 80 500 500 7507 8x SM G.657.A 7,9 69 0 85 500 500 7507 x SM G.657.A 7,9 69 5 90 500 500 7507 x SM G.657.A 8,5 78 5 90 500 500 Copyright (c) TKF, -0-0 Page /

Product information Cable construction and colour code CTC LSZH FO cable with central tube Indoor/Outdoor application Description: Optical fibres Central tube with,, 6, 8,, 6 or fibres Reinforcement of glass yarns Outer sheath (LSZH) Standard Colours: Fibrenr. Group Fibrenr. Red Green Blue 5 Yellow 6 5 White 7 6 Grey 8 7 Brown 9 8 Violet 0 9 Turquoise 0 Black Orange Pink Group Red +t Green +t Blue +t Yellow +t White +t Grey +t Brown +t Violet +t Turquoise +t Natural Orange +t Pink +t note +t: indicates a black tracer Version : PM-M05J Subject to technical alterations Page / This data sheet is put together with great care. Nevertheless we can not give any guarantees regarding the completeness, correctness or actualization of the information. No rights can be derived from the information as shown. TKF is entitled to modify this data sheet at all times with immediate effect due to (for example) changes in legislation. TKF can not be held responsible for the content of this data sheet or the consequences of using the information including incorrect translation of the information by third parties.

LTC LSZH LTC LSZH - Universal, Metallfree, Loose Tube Cable. Non-metallic, loose tube universal (indoor/outdoor) cable, longitudinal water-protected, with Low Smoke Zero Halogen outersheath. Installation: by blowing or pulling, into conduits or on cable trays. Characteristics Properties Unit Product group Universal cables Series Type Glasvezelkabel Single Mode LTC LSZH Standardization IEC 6079--0 Test procedures IEC 6079-- Application Blow in Strain relief Optical Element Fibre type Optical fibre standard Strip method Material outer sheath Colour outer sheath Article dependant, see detail sheet Loose tube, gel filled Single mode ITU-T G.657.A Rip cord LSZH Black Flame retardant Acc. IEC 60-- Halogen free Halogen free (acc. EN 5067--) UV resistant Article dependant, see detail sheet UV-protection ISO 89/ Cable metal free Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature Article dependant, see detail sheet C Operation temperature range Article dependant, see detail sheet C Transportation and storage temperature -0 / 70 C Attenuation @ 0 nm 0.5 db/km Attenuation @ 550 nm 0. db/km Attenuation @ 65 nm 0.5 db/km Construction and Colour codes zie bijlagen Page /

LTC LSZH Partnumber Description Outer diameter approx. Net weight (Kg/km) radius after radius during short term (Tm) (N) Long Term (Tl) (N) 77500 x SM G.657.A (x) 0 8 50 00 000 500 7750 6x SM G.657.A (x) 0 8 50 00 000 500 7750 8x SM G.657.A(x) 0 8 50 00 000 500 7750 x SM G.657.A (6x) 0 8 50 00 000 500 7750 x SM G.657.A (x) 0 8 50 00 000 500 77505 x SM G.657.A (6x) 0 8 50 00 000 500 77506 x SM G.657.A (x) 0, 80 50 00 900 900 77507 6x SM G.657.A (6x6) 0 8 50 00 000 500 77508 6x SM G.657.A (x) 0, 8 50 00 900 900 77509 8x SM G.657.A (8x6), 08 70 0 500 500 7750 8x SM G.657.A (6x8) 0,9 00 60 0 500 500 775 8x SM G.657.A (x) 0, 8 50 00 900 900 775 60x SM G.657.A (5x) 0, 8 50 00 900 900 775 7x SM G.657.A (6x) 0,9 0 60 0 500 500 775 8x SM G.657.A (7x),7 8 75 5 000 000 758 96x SM G.657.A (8x),6 9 85 50 000 000 7756 0x SM G.657.A (0x), 65 0 80 500 000 7758 x SM G.657.A (x) 5,9 0 0 0 500 000 706 x SM G.657.A ((6++8)x),0 67 0 0 000 500 Copyright (c) TKF, -0-0 Page /

Product information Cable construction and colour code LTC LSZH FO cable with stranded loose tubes Indoor / Outdoor application 6 5 7 5 6 7 Description: Centre element, FRP optional with over sheath Loose tube with optical fibres (,, 6, 8, or fibres per tube) Water blocking yarns or tape Filler 5 Water blocking tape 6 Ripcord (optional) 7 Outer sheath (LSZH) Standard Colours: Fibres Tubes Group Group Layer Layer Layer Red Red +t Red Red Red Green Green +t Green Green Green Blue 5 Blue +t Blue Blue Blue Yellow 6 Yellow +t Yellow Yellow Yellow 5 White 7 White +t 5 White 5 White 5 White 6 Grey 8 Grey +t 6 Grey 6 Grey 6 Grey 7 Brown 9 Brown +t 7 Brown 7 Brown 7 Brown 8 Violet 0 Violet +t 8 Violet 8 Violet 8 Violet 9 Turquoise Turquoise +t 9 Orange 9 Orange 9 Orange 0 Black Natural 0 Black 0 Black 0 Black Orange Orange +t Pink Pink Pink Pink Pink +t Turquoise Turquoise Turquoise Red Red Green Green 5 Blue 5 Blue 6 Yellow 6 Yellow note +t: indicates a black tracer Version : PM-M05J Subject to technical alterations Page / This data sheet is put together with great care. Nevertheless we can not give any guarantees regarding the completeness, correctness or actualization of the information. No rights can be derived from the information as shown. TKF is entitled to modify this data sheet at all times with immediate effect due to (for example) changes in legislation. TKF can not be held responsible for the content of this data sheet or the consequences of using the information including incorrect translation of the information by third parties.

LTC HFFR LTC HFFR - Halogen Free Flame Retardant. Robust, non-metallic, loose tube universal (indoor/outdoor) cable, rodent-protected, longitudinal waterprotected, with a Halogen Free Flame Retardant outersheath. This cable meets the requirements of IEC - (Flame-retardancy) and is therefore perfectly suitable for in tunnels, subway, ship, rail, public buildings, etc. Installation: by blowing or pulling, into conduits or on cable trays. Characteristics Properties Unit Product group Universal cables Series Type Glasvezelkabel Single Mode LTC HFFR Test procedures IEC 6079-- Application Blow in Strain relief Optical Element Fibre type Optical fibre standard Material outer sheath Colour outer sheath Halogen free (acc. EN 5067--) Inside/outside Loose tube, gel filled Single mode ITU-T G.657.A LSZH Grey Flame retardant Acc. IEC 60- Halogen free Acc. IEC 6075- UV resistant Cable metal free Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 50 C Operation temperature range -0 / 70 C Transportation and storage temperature -0 / 70 C Attenuation @ 0 nm 0.5 db/km Attenuation @ 550 nm 0. db/km Attenuation @ 65 nm 0.5 db/km Construction and Colour codes zie bijlagen Page /

LTC HFFR Partnumber Description Outer diameter approx. Net weight (Kg/km) radius after radius during short term (Tm) (N) Long Term (Tl) (N) 7770 xsm G.657.A (x), 57 85 50 00 500 7770 6xSM G.657.A (x), 58 85 50 00 500 7770 8xSM G.657.A (x), 59 85 50 00 500 7770 60xSM G.657.A (5x), 60 85 50 00 500 77705 7xSM G.657.A (6x), 6 85 50 00 500 77706 96xSM G.657.A (8x),0 0 0 80 5000 000 77707 0xSM G.657.A (0x) 5,8 56 0 0 500 500 77708 xsm G.657.A (x) 7,5 08 65 50 5500 000 Copyright (c) TKF, -0-0 Page /

Product information Cable construction and colour code LTC HFFR FO cable with stranded loose tubes, Indoor/outdoor application Halogen Free Flame Retardant acc. IEC 60-- class C 6 7 5 8 Description: 5 6 7 8 Centre element, FRP optional with over sheath (LSZH) Loose tube with optical fibres (,, 6, 8 or fibres per tube) Water blocking yarns or tape Filler Water blocking tape Glass yarn strength members (Rodent Protection) Ripcord (optional) Outer sheath (HFFR, Grey) Standard Colours: Fibres Tube Fibrenr. Group Layer Red Green Blue Yellow 5 White 5 6 Grey 6 7 Brown 7 8 Violet 8 9 Turquoise 9 0 Black 0 Orange Pink Red Green Blue Yellow White Grey Brown Violet Orange Black Pink Turquoise Version : PM-M05J Subject to technical alterations Page / This data sheet is put together with great care. Nevertheless we can not give any guarantees regarding the completeness, correctness or actualization of the information. No rights can be derived from the information as shown. TKF is entitled to modify this data sheet at all times with immediate effect due to (for example) changes in legislation. TKF can not be held responsible for the content of this data sheet or the consequences of using the information including incorrect translation of the information by third parties.

LTC RP LSZH LTC RP LSZH - Universal, Metallfree, Loose Tube Cable Rodent-Protected. Robust, non-metallic, loose tube universal (indoor/outdoor) cable, rodent-protected, longitudinal waterprotected, with Low Smoke Zero Halogen outersheath. Installation: by blowing or pulling, into conduits or on cable trays. Characteristics Properties Unit Product group Universal cables Series Type Glasvezelkabel Single Mode LTC RP LSZH Standardization IEC 6079--0 Test procedures IEC 6079-- Application Blow in Strain relief Optical Element Fibre type Optical fibre standard Strip method Material outer sheath Colour outer sheath Halogen free (acc. EN 5067--) Inside/outside Loose tube, gel filled Single mode ITU-T G.657.A Rip cord LSZH Black Flame retardant Acc. IEC 60-- UV resistant UV-protection ISO 89/ Cable metal free Longitudinal water blocking Longitudinal watertight construction Super Absorbing Polymer Installation temperature -5 / 50 C Operation temperature range Article dependant, see detail sheet C Transportation and storage temperature -0 / 70 C Attenuation @ 0 nm 0.5 db/km Attenuation @ 550 nm 0. db/km Attenuation @ 65 nm 0.5 db/km Construction and Colour codes zie bijlagen Page /

LTC RP LSZH Partnumber Description Outer diameter approx. Net weight (Kg/km) radius after radius during short term (Tm) (N) Long Term (Tl) (N) 758 x SM G.657.A (x) 0,6 95 60 5 000 000 759 6x SM G.657.A (x) 0,6 95 60 5 000 000 750 8x SM G.657.A (x) 0,6 96 60 5 000 000 75 x SM G.657.A (6x) 0,6 97 60 5 000 000 75 x SM G.657.A (x) 0,5 95 60 5 000 000 75 x SM G.657.A (6x) 0,5 97 60 5 000 000 708 x SM G.657.A (x) 0,6 9 60 0 000 000 755 6x SM G.657.A (6x6) 0,6 98 60 0 000 000 757 6x SM G.657.A (x) 0,6 95 60 0 000 000 758 8x SM G.657.A (6x8), 70 0 000 000 759 8x SM G.657.A (x) 0,6 96 60 0 000 000 75 7x SM G.657.A (6x), 70 0 000 500 75 96x SM G.657.A (8x),9 95 60 000 000 75 0x SM G.657.A (0x), 77 0 00 5500 000 75 x SM G.657.A (x) 6, 6 5 0 5500 000 76 9x SM G.657.A ((5+)x) 5,8 98 0 0 500 500 77 x SM G.657.A ((6+)x) 9,8 00 00 5000 500 7596 576x SM G.657.A ((9+5)x), 6 5 65 5000 000 78 768x SM G.657.A ((5++6)x),9 8 80 50 5000 500 Copyright (c) TKF, -0-0 Page /

Product information Cable construction and colour code LTC RP LSZH FO cable with stranded loose tubes Rodent Protection, indoor/outdoor application 6 7 Description: Centre element, FRP optional with over sheath Loose tube with optical fibres (,, 6, 8, or fibres per tube) Water blocking yarns or tape Filler 5 Water blocking tape 6 Glass yarn strength members (Rodent Protection) 7 Ripcord (optional) 8 Outer sheath (LSZH) 5 8 5 6 7 8 Standard Colours: Fibres Tubes Group Group Layer Layer Layer Red Red +t Red Red Red Green Green +t Green Green Green Blue 5 Blue +t Blue Blue Blue Yellow 6 Yellow +t Yellow Yellow Yellow 5 White 7 White +t 5 White 5 White 5 White 6 Grey 8 Grey +t 6 Grey 6 Grey 6 Grey 7 Brown 9 Brown +t 7 Brown 7 Brown 7 Brown 8 Violet 0 Violet +t 8 Violet 8 Violet 8 Violet 9 Turquoise Turquoise +t 9 Orange 9 Orange 9 Orange 0 Black Natural 0 Black 0 Black 0 Black Orange Orange +t Pink Pink Pink Pink Pink +t Turquoise Turquoise Turquoise Red Red Green Green 5 Blue 5 Blue 6 Yellow 6 Yellow note +t: indicates a black tracer Version : PM-M05J Subject to technical alterations Page / This data sheet is put together with great care. Nevertheless we can not give any guarantees regarding the completeness, correctness or actualization of the information. No rights can be derived from the information as shown. TKF is entitled to modify this data sheet at all times with immediate effect due to (for example) changes in legislation. TKF can not be held responsible for the content of this data sheet or the consequences of using the information including incorrect translation of the information by third parties.