Air and Vapor Barrier 3015

4411N 4411G 4412N 4412G

Fire Protection Products

Extreme Sealing Tape

Smart Vapor Retarders

Insulations, Sheathings and Vapor Retarders

Structural Performance Tests of VHB Structural Glazing Tapes

3 700-Series Hybrid Products:

A new method for protecting construction joints and through-penetrations from fire, water, smoke and sound.

3 Scotch-Weld TM. Epoxy Adhesive EC Technical Data November, 2010

breathability to prevent the potential for moisture condensation within exterior walls...

AIR BARRIERS & WATER-RESISTIVE BARRIERS

Adhesion Promoter/Primer 3M Adhesion Promoter AP596

PLATON RUGGED, DIMPLED HIGH-DENSITY POLYETHYLENE (HDPE) MEMBRANE THAT KEEPS FOUNDATIONS AND FLOORING DRY ADVANCED TECHNOLOGY EASY INSTALLATION

Moisture Considerations for Insulated Building Assemblies

3M Thermal Management Solutions for LED Assembly

Owens Corning PinkWrap Housewrap, the brand trusted to protect your home from moisture and the elements.

Vapour Diffusion for Residential Construction. Canada and Northern USA VAPOUR DIFFUSION FOR RESIDENTIAL CONSTRUCTION CANADA AND NORTHERN USA

The Original. The Innovator.

The Building Envelope Solution. Mike Lowery A&D Products, LLC

The Role of Control Layers in Building Enclosure Design

Trends in Adhesives and Tapes Bonding Dissimilar Materials Using Adhesives and Tapes

Tapes. Reliable. Solar Industry. for the. 3M Tapes for Solar Panel Fabrication

Next Generation Structural Acrylic Adhesives. Enhance Productivity and Performance

Inside Why Spray polyurethane Foam insulation? All About Spray polyurethane Foam Book 1

Adhesive Transfer Tapes with

2006 Building Science Press All rights of reproduction in any form reserved.

Commercial Air Barrier Systems

Parex Continuous Insulation (CI)

2

Endotherme Mat ES-5A-12

Integrated Air & Water Barrier Systems

3 Scotch-Weld TM. Epoxy Adhesive 2158 B/A. Technical Data December, 2009

Henry Blueskin VP160 Air Barrier System Installation Manual

Air Barrier Requirements for Low-Slope Roof Assemblies Myths vs. Facts

MasterSeal HLM Liquid cold-applied elastomeric waterproofing membrane system

Double Coated Urethane Foam Tapes

3M Fast Tack Water Based Adhesive 1000NF

3M Industrial Masking Tapes

Building Enclosure Performance for Existing and New Buildings

United States R E S I D E N T I A L. The Value of Residing With STYROFOAM Brand XPS Insulation

VHB Adhesive Transfer Tapes with High Performance Acrylic Adhesive 100MP F9460PC F9469PC F9473PC

Acrylic Structural Adhesives. Features and Recent Advancements

3M Abrasive Systems Division. Sanding made simple.

Crawl Space Moisture Control

Avoiding Air Barrier Pitfalls When sub-trade activities are not in sync with air barrier requirements, installation can go poorly.

Scotch-Weld TM Polyurethane Reactive Adhesives

2001 National Workshop on State Building Energy Codes July th, 2001 Burlington, Vermont

3M Spray Adhesives Performance. Productivity. Efficiency. Streamline your assembly operation with convenient, efficient 3M Spray Adhesives.

3M Cold Shrink Silicone Rubber Connector Insulators 8440 Series

Installation Guide April 2017

Building code language is unclear regarding low-slope roof assembly ventilation. by Brian Erickson, P.E., and Liberty Lewis, P.E.

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

CertainTeed DRYRIGHT. Moisture Control Fiber Glass Insulation

CSI Boston Technical Paper No. 1: Specifying Air Barriers Air Barriers

2013 COMMERCIAL PRODUCTS

Improve Energy Efficiency and Air Sealing in Above-Grade Walls

3M Electrically Conductive Double-Sided Tape 9711S Series

BUILDING ENVELOPE PRODUCTS PROVIDING A FULL BUILDING ENVELOPE SYSTEM. Control Moisture Movement with Our Patented Technology

10 Steps to Save Energy in Your House

BROADCAST: M BLOCKS, PLUGS, PLANKS NEW PRODUCT LAUNCH Date: June 16, 2016 Issued by: George Yoshida, Ted Colwell

Throughout the balance of this paper the terms attic and roof will and can be used interchangeably.

Vario XtraSafe. Airtightness and moisture management system.

Weather Resistant Barrier

CertainTeed TECHNICAL BROCHURE

When R-Value Doesn t Measure Up

Vancouver Field Exposure Facility: Phase IV Construction and Instrumentation Report

Fire Barrier Duct Wrap 615+

3M Decorative Polyester Glass Film

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

3M Electrically Conductive Cushion Gasket Tape

MAKE ROOFS LAST LONGER

Scotch-Weld TM. Epoxy Adhesive/Coating Technical Data July, 2011

SINGLE FAMILY USER S BULLETIN FOR INSTALLATION OF DUPONT WEATHERIZATION SYSTEMS PRODUCTS

Lock In Energy Savings For Life

How do you install yours?

TEKTON Flashings and TEKTON Construction Tape

INSULATION OWENS CORNING INSULATION PRODUCTS IN THIS SECTION:

Mechanical Insulation for Refrigeration Systems

WATERPROOFING TAMKOWATERPROOFING.COM

3M Contrast Enhancement Film

EZ EZ EZ250200

Double Coated Urethane Foam Tapes

The Role of Control Layers in Building Enclosure Design

Techna-Duc. Advantages. Features and Benefits. LEED Eligible Product

For detailed product information, visit our DeckOver, Textured DeckOver or Extra Textured Deckover product pages.

VAPROLIQUI-FLASH. Liquid Applied Waterproof Flashing Material INSTALLATION INSTRUCTIONS

Insulating Basements: Part 1 Fundamentals

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

3M Anisotropic Conductive Film 5363

Scotch-Weld Metal Bonder Acrylic Adhesive DP8407NS Gray

3 Water Contact Indicator Tape 5557 Condensation Test

3M Electrical, Electronic and EMI Shielding Tapes Selection Guide

ELEVATION FOR DETAIL REFERENCE ONLY

Exterior Building Materials & Detailing

Thermal Transfer Polyester Label Material

ENERGY PERFORMANCE R-VALUE: PART 2, EXAMPLES OF INTEGRATED METHODOLOGY FOR EVALUATION OF ENERGY EQUIVALENT R-VALUE FOR BUILDING ENCLOSURES;

Spray Polyurethane Foam. Insulation and Air Barrier Requirements of the 2012 I-Codes. Spray Foam Coalition

3 Scotch-Weld TM. Instant Wood Adhesives and Surface Activator. Technical Data April, 2007

Application Specification:

Transcription:

Advanced technologies for enhancing the building envelope 3M Building and Construction Market

Controlling air is crucial for the health & energy efficiency of buildings Ensuring you have the right air barrier for your new building project is important to the success of your project. Without an effective air barrier, uncontrolled air movement can cause condensation of moisture on cold surfaces (see image below) and can harm the long-term performance and durability of your building materials. It can also decrease indoor air quality, make your building less energy efficient and could negatively affect the health of the people inside the building. Winter Summer Air Air flow Flow Air Air flow Flow WARM COLD COLD COLD WARM INTERIOR EXTERIOR Moisture Condensation INTERIOR EXTERIOR Moisture Condensation HUMID DRY DRY HUMID HUMID Vapour Vapor Diffusion Vapour Vapor Diffusion In winter, warm, humid air moves naturally from building interiors to colder, drier exteriors. Without air barriers, moisture will condense on the colder, inside surface of the exterior wall. In summer, warm, humid air moves naturally from building exteriors to cooler, drier interior areas. Without proper air and vapour control, moisture will condense on the colder, inside surface of the interior wall. Uncontrolled air flow can be a major problem, especially in cold-weather It s been estimated that over the course of a heating season about one third of a litre of water can pass directly through gypsum board without a vapour retarder, and that 30 quarts of water can pass through the same gypsum wall with just a 1" x 1" hole in that same time period. 1 1 Builder s Guide to Cold Climates, Joseph Lstiburek 4' x 8' sheet of gypsum board interior at 21 C & 40% RH Vapour diffusion through solid board = 1/3 quart of water over the course of one heating season Diffusion vs. Air Leakage 1"x 1" hole 4' x 8' sheet of gypsum board interior at 21 C & 40% RH Air leakage = Up to 30 quarts of water over the course of one heating season 3

Solve Construction-Related Environmental Challenges With the Right Air Barrier Modern buildings can be affected by many environmental challenges that can significantly affect their performance. Wind pressure. The forces of wind on a building can be broken down into two categories: positive (windward) pressure tries to push air into the building and negative (leeward) pressure tries to draw air out of the building, most commonly through gaps and openings within the structure. Fan pressurization. Mechanical (HVAC) systems are designed to create air movement within a building. The supply side of the system creates positive pressure that delivers conditioned air to the desired locations, while the return side and exhaust vents recycle and remove air, creating negative pressure. These systems must be balanced in order to perform properly. Stack pressure. Air density is related to air temperature. As air temperature warms, it becomes lighter and rises. The opposite is also true. As air temperature cools, it becomes denser and falls. A classic example of this is a hot air balloon. Barometric cycling. Air pressure changes due to the weather. High pressure is associated with nice weather while low pressure is associated with inclement weather. This is typically not an issue inside buildings except when there are rapid pressure drops, such as those that can result in tornadoes. The rapid pressure changes between the interior and exterior can cause windows to blow out, as the building pressure tries to balance itself with the ambient conditions. Thermal cycling. All construction materials shrink with cold and expand with heat over the 24-hour period from the cool of the night to the heat of the day. Materials are either extracting or emitting heat or cold, which causes the building HVAC system to respond in order to maintain the desired temperature. Common environmental challenges of buildings A continuous air barrier helps maximize building efficiency Wind Pressure (Positive Load) Wind Pressure (Negative Load) Fan Pressure Stack Pressure Interior Air Flow Exterior Air Flow Fan Pressure Typical building without an air barrier system Building with a continuous air barrier system 4

The Power to Choose the Right Air Barrier System Each Time, Every Time Depending on their material characteristics, air barriers can control or block the passage of water vapour. Vapour permeable air barriers Air barriers are permeable systems that allow vapour transmission through a wall assembly. The perm rating is typically greater than 10 ( perm rating is a measure of the diffusion of water vapour through a material). Air and Vapour barriers These nonpermeable systems stop air and moisture transmission through the wall assembly. They typically have a perm rating of less than 1.0. Choosing the right air barrier system is dependent on the kind of wall assembly you are constructing (the primary driver), your climate location (secondary driver), and your goals for sustainable construction. Once you have selected a wall assembly design, the application temperature and weather conditions will determine the best barrier type. For example, cold or wet weather may eliminate some coatings and sheet membrane systems from consideration. Maximize your building efficiency Protecting buildings with a continuous 3M Air Barrier System could provide a wide range of benefits, including: Better indoor air quality Less risk of mould and mildew compared to most traditional air barrier systems Happier, healthier residents Extended service life and durability of your building Energy savings through the reduction of unintended air movement An air barrier system is a sheet or spray-applied membrane. It is designed to control the unintended movement of air flow into and out of the building enclosure. 4B 3 1A 3M Air and Vapour Barrier 3015 1A 1B 3M Air Barrier 3015VP 2 3M Through Wall Flashing Tape 3015TWF 4A Exterior Gypsum Sheathing 3 3M Scotch-Weld HoldFast 70 Cylinder Spray Adhesive 4A Continuous insulation 1B 4B Fiberglass batt insulation 2 Vapour Diffusion 4A Air Leakage 3 5

Control Airflow with Confidence 3M Air and Vapour Barrier 3015 Using advanced technology to reduce air leakage and uncontrolled airflow can have a positive impact on your bottom line. The 3M Air and Vapour Barrier 3015 is a self-adhered membrane engineered to help you do just that. It helps prevent moisture ingress and helps improve indoor air quality. Among other features, air barrier designs ensure that the air temperature curve within the wall assembly is always higher than the dew point temperature curve. Read below about how 3M Air and Vapour Barrier 3015 can protect the health of your building. No primer required *. Pressure-sensitive adhesive technology eliminates the time and materials usually required for applying air barriers. Compatible with common construction materials and sealants. The special adhesive sticks well to concrete, concrete block, anodized aluminum, galvanized metal, plywood, extruded polystyrene and most exterior gypsum sheathing. It is compatible with a wide range of common sealants, including synthetic rubber, butyl, polyurethane, silicone and silane-terminated hybrid sealants. Hot and cold temperature application. Apply 3M Air and Vapour Barrier 3015 in temperatures as high as 66 C (150 F) or as low as -18 C (0 F). Self-seals if penetrated. Seals around nails and staples to further reduce moisture intrusion. It passes ASTM D1970 both before and after thermal cycling. Flexible. Flexible enough to fit into corners, under siding and around curved surfaces. Lightweight and easy to use. A standard 36" roll of 3M Air and Vapour Barrier 3015 weighs 9.5 kilograms, yet it outperforms thicker, competitive membranes weighing up to three times more! Class A Fire Rating. The flame spread rating of 3M Air Barrier Membrane 3015 is much lower than competitive bitumen based membranes. UV resistant up to 12 months Nonpermeable. U.S. perm rating = 0.14 per ASTM E96 (desiccant method). *No primer required on most construction surfaces. 6

Waves of Acrylic Adhesive 3M Vapour Permeable Air Barrier 3015VP Self-seals if penetrated. Seals around nails and staples to further reduce moisture intrusion. It passes ASTM D1970 both before and after thermal cycling. Engineered to make air barrier application simple and fast, this vapour-permeable barrier is more effective for helping control indoor climate. yet it outperforms thicker, competitive membranes weighing up to two times more! Additionally, the reverse wound roll increases the ease of installation and productivity. Hot and cold temperature application. Apply 3M Vapour Permeable Air Barrier 3015 VP in temperatures as high as 66 C (150 F) or as low as -18 C (0 F). Tough and flexible. Flexible enough to fit into corners, under siding and around curved surfaces tough enough to resist punctures and tears. UV resistance up to 12 months. Compatible with other 3M Building and Construction Market products. 3M Vapour Permeable Air Barrier 3015VP for detailing and combining with 3M Polyurethane Sealant 540 provides a complete air barrier assembly (Tested to CAN/ULC S742). No primer required *. Pressuresensitive adhesive technology eliminates the time and materials usually required for applying air barriers. Reverse wound rolls. We know application of membranes can be a backbreaking task. The adhesive is on the outside of the 3M Vapour Permeable Air Barrier 3015 VP. Application is as easy as sticking the roll to the wall and rolling it out. Permeable. U.S. perm rating > 10 as per ASTM E96, ensuring a permeable barrier > 10 perms Lightweight and easy to use. A standard 30" roll of 3M Vapour Permeable Air Barrier 3015 VP weighs two kilograms 7 *No primer required on most construction surfaces.

The easiest decision you will make today 3M Through Wall Flashing Membrane 3015TWF $ Easy to apply. Comes on an easy-tohandle roll that can be applied in just one step by a single applicator. Hot and cold temperature application. Apply 3M Through Wall Flashing Tape 3015TWF in temperatures as high as 66 C (150 F) or as low as -18 C (0 F). Durable membrane designed to withstand wear and tear. This product is tough enough to resist punctures and tears. The patented acrylic-based adhesive can stick to a wide range of building materials, from concrete to metal to wood even when they re damp. No primer required *. You can almost forget budgeting time and money for preparation and clean-up at the job site! 3M Through Wall Flashing 3015 TWF requires no primer. Walk into and out of the job site without thinking of primerrelated spills and mess. 24M Compatible with other 3M Building and Construction Market products. 3M Vapour Permeable Air Barrier 3015VP for detailing and combining with 3M Polyurethane Sealant 540 provides a complete air barrier assembly (Tested to CAN/ULC S742). UV resistant up to 24 months. *No primer required on most construction surfaces. 8

3M Vapour Permeable Air Barrier 3015VP 30" x 75' 3M Through Wall Flashing Tape 3015TWF 3M Air & Vapour Barrier 3015 9" x 75' 12" x 75' 16" x 75' 18" x 75' 23/8" x 75' 4" x 75' 6" x 75' 9" x 75' 12" x 75' 18" x 75' 36" x 75' 48" x 75' Learn about 3M s advanced technologies for controlling airflow and optimizing the indoor climate at 3M.ca/buildingenvelope or contact your 3M representative at 1-888-364-3577. Warranty, Limited Remedy, and Disclaimer: Many factors beyond 3M s control and uniquely within user s knowledge and control can affect the use and performance of a 3M product in a particular application. User is solely responsible for evaluating the 3M product and determining whether it is fit for a particular purpose and suitable for user s method of application. Unless an additional warranty is specifically stated on the applicable 3M product packaging or product literature, 3M warrants that each 3M product meets the applicable 3M product specification at the time 3M ships the product. 3M MAKES NO OTHER WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED, ANY IMPLIED WARRANTY OR CONDITION OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR ANY IMPLIED WARRANTY OR CONDITION ARISING OUT OF A COURSE OF DEALING, CUSM OR USAGE OF TRADE. If the 3M product does not conform to this warranty, then the sole and exclusive remedy is, at 3M s option, replacement of the 3M product or refund of the purchase price. Limitation of Liability: Except where prohibited by law, 3M will not be liable for any loss or damage arising from the 3M product, whether direct, indirect, special, incidental or consequential, regardless of the legal theory asserted, including warranty, contract, negligence or strict liability. 3M Industrial Adhesives and Tapes Division 3M Canada 300 Tartan Drive London, Ontario N5V 4M9 1-800-364-3577 www.3m.ca/buildingenvelope For technical claims and further information, please contact your 3M representative. 3M, 3M Science. Applied to Life., and Scotch-Weld are trademarks of 3M. Used under license in Canada. GP Densglas is a trademark of Georgia-Pacific Gypsum, LLC. 2017, 3M. All rights reserved. 170609078 E BA-17-24150