EFFECTS OF HUMAN BEHAVIOR ON INHALATION EXPOSURE TO RADON VOLATILIZED FROM DOMESTIC WATER USES

Similar documents
MEAN ANNUAL EXPOSURE OF CHILDREN AGED 0-4 YEARS TO ATMOSPHERIC PARTICULATE POLLUTION

Florida Energy Extension Service

Corridor Pressurization System Performance in Multi-Unit Residential Buildings

Indoor Building Survey and Product Inventory

U.S. EPA s Vapor Intrusion Database: Preliminary Evaluation of Attenuation Factors

External Environment and Indoor Microclimate

ACHIEVING HIGH-PERFORMANCE MULTI-UNIT RESIDENTIAL BUILDINGS: THE OPPORTUNITIES

Health Consultation. South Indian Bend Wash Landfill Area TEMPE, MARICOPA COUNTY, ARIZONA. CERCLIS No. AZD

A STUDY OF CROSS CONTAMINATION OF IN-SUITE VENTILATION SYSTEMS USED IN MULTI-UNIT RESIDENTIAL BUILDINGS

A screening model for predicting concentrations of volatile organic chemicals in shower stall air

37% 100% 100% PROJECT HIGHLIGHTS LEED Facts. Wiener Auditorium

NOTE: Some guidance on a performance approach to natural ventilation systems design is provided in the Supplement to this Standard.

6.3.2 Exposure Assessment

Before You Start Renovating Your Bathroom

Building & Fire Appeals Board

ASHRAE Standard 62.1 Ventilation Report

LEED v4 for Homes, Residential Project Summary and Checklist One and Two Family New Construction

RESIDENTIAL RADON LEVELS IN HONG KONG

WM 00 Conference, February 27 - March 2, 2000, Tucson, AZ

COMPLEX SYSTEM OF RADON DIAGNOSIS METHODS AND SPECIFIC EXPERIMENTAL AND THEORETICAL PROCEDURES APPLIED IN THE INDOOR BUILDING ENVIRONMENT ABSTRACT

TOPIC #12: GENERAL PUBLIC EXPOSURES SYNOPSIS

Norm survey in Argentina

Advanced Ventilation for Residential applications FBC Res 2010.

ASHRAE 62.2: What s New in 2016

A Field Study of Airflow in Mid to High-Rise Multi-Unit Residential Buildings

CHROMIUM EXPOSURE AND HEALTH EFFECTS IN HUDSON COUNTY

Greywater Recycling Systems: Can These Systems Gain Public Support?

BASEMENT FINISH CONSTRUCTION PLANS REFERENCE: 2015 INTERNATIONAL RESIDENTIAL CODE. PERMITS

COMMUNITY AND PERSONAL EXPOSURES TO AIRBORNE CONTAMINANTS IN AN URBAN-INDUSTRIAL HOT SPOT

Water Quality in East Chicago. December 12, 2016

2012 IRC Sections R303 R310 Building Planning II

Assessment of Airborne Exposure to Trihalomethanes from Tap Water in Residential Showers and Baths

Evergreen Project Implementation Plan Instructions Low Income Housing Tax Credit Program

WARWICK TOWNSHIP Dept. of Planning & Zoning

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 9/30/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

EVALUATION OF THE INDOOR AIR QUALITY IN A SINGLE FAMILY ACTIVE HOUSE

TOWNSHIP OF LOGAN 125 MAIN STREET, PO BOX 314 BRIDGEPORT, NJ FAX

East Hanover Water Quality Report 2014 PWS ID#

Thermal Comfort Evaluation of HDB flats

EFFECT OF HEAT DISCHARGE BY NATURAL VENTILATION ON INDOOR ENVIRONMENT AND HEAT REMOVAL STRUCTURE

Fresh Air Ideas SUPPORTING GREEN INITIATIVES WITH INNOVATION

Quality of Rainwater From Rainwater Harvesting Systems in Sanaa. Nagib Ghaleb N. Mohammed, Civil Engineering Department, University of Bahrain

88.2% 32% 23% WEITZ LABORATORY GOLD. PROJECT HIGHLIGHTS LEED Facts. of on-site generated construction waste was diverted from landfills.

RADON LEVELS INSIDE RESIDENCES IN MEXICO CITY. G. Espinoza. National University of Mexico Mexico City, Mexico. and

Energy Efficiency Solutions for Multifamily Housing. Clark Energy Group LLC

Water Savings in Eddy Home Households. Dr. Tricia Barfoot, July 2017

Energy-Efficient Passive House using thermal mass to achieve high thermal comfort

INTERIOR ENVIRONMENT

ASHRAE and Indoor Air Quality

4.3 MANSE GUIDELINES

LEED 2009 for New Construction and Major Renovations

Annual Drinking Water Quality Report

McCollum Hall Classroom Renovation Project Profile LEED-CI Gold, August 2007

UC Berkeley Indoor Environmental Quality (IEQ)

RESIDENTIAL MOLD ASSESSMENT. Final Report. Your Address Here

Best management practices for vapor investigation and building mitigation decisions

COMPARISON OF THE STANDARDIZED REQUIREMENTS FOR INDOOR CLIMATE IN OFFICE BUILDINGS

Critical Review of the Building Downwash Algorithms in AERMOD

Dynamic Simulation Of Long-term Indoor VOC Concentrations In A Newly Renovated Residential Unit: A Pilot Study

ADDENDUM NO. FIVE TO THE DESIGN-BUILD REQUEST FOR PROPOSAL (RFP) DOCUMENTS September 26, 2016

FLOORPLAN /ELEVATION SQ.FT. BDRM BATHS GARAGE BASE PRICE

A Solar Wall System Utilized in Rural Houses of Northeast China

Future of Home Heating Supplemental Materials. A Collaboration Between:

Continuing Certificate of Occupancy Pre-Inspection Checklist

TOTAL UTILITY DEMAND PREDICTION FOR MULTI-DWELLING SITES CONSIDERING VARIATION OF OCCUPANT BEHAVIOR SCHEDULES

VI. WATER QUALITY MODELING

Compliance Evaluation: ASHRAE Standard Ventilation for Acceptable Indoor Air Quality

VILLAGE OF GREENWICH STATE OF OHIO Administration Offices: 45 Main Street. Greenwich, Ohio (419)

INTERIOR ENVIRONMENT

INTRODUCTION: WHERE DOES OUR WATER COME FROM?

Evaluation of Spatial and Temporal Variability in VOC Concentrations at Vapor Intrusion Investigation Sites.

Home Built to LEED- H Silver Standards Monmouth County, NJ

Identifying Strong ROI Opportunities for Green Upgrades and Engaging your Entire Portfolio on Incremental Change

Introduction to Drinking Water Systems. Indiana Basics Course for Small Public Drinking Water Systems -1

AIRBORNE PARTICULATE MATTER WITHIN 100 RANDOMLY SELECTED OFFICE BUILDINGS IN THE UNITED STATES (BASE)

One and Two Family Additions

HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS

MOLD INSPECTION REPORT Block Home Inspections LLC

Of Building Science: From Control Layers to High Performance Enclosures

DENR Public Water Supply Section FIGURE 1(A): ALKALINITY VS PH

Using a Aerosol Sealant to Reduce Multifamily Envelope Leakage

LEED v4 Building Design and Construction Quiz #8 EQ

2014 White Earth Drinking Water Report

Relationship among Concentrations of Indoor Air Contaminants, Their Sources, and Different Mitigation Strategies on Indoor Air Quality

A RESIDENTIAL END-USE ENERGY CONSUMPTION MODEL FOR CANADA

DESIGNING COMMERCIAL SUB-SLAB DEPRESSURIZATION SYSTEMS

Analysis of Potential Water Savings from Residential and Irrigation Accounts in the South Platte Basin Through 2050

Keep your home. FREE from DAMP, CONDENSATION and MOULD

Inspection Report. 1 of 8

A REVIEW OF VAPOR INTRUSION GUIDANCE BY STATE

Flexible Vapor Control Solves Moisture Problems of Building Assemblies - Smart Retarder to Replace the Conventional PE-Film

Modeling the impact of residential HVAC filtration on indoor particles of outdoor origin (RP-1691)

THE RESTORE LOUISIANA REIMBURSEMENT ESTIMATE

Project Summary. Marc Y. Menetrez and Russell N. Kulp

WE 1: ENHANCE WATER EFFICIENCY STANDARDS

COMPONENTS OF THE NOISE ELEMENT

2015 Annual Drinking Water Report Martinsburg Municipal Authority

AIRFLOW PATTERNS AND STACK PRESSURE SIMULATION IN A HIGH RISE RESIDENTIAL BUILDING LOCATED IN SEOUL

WATER QUALITY REPORT FOR 2016

Transcription:

EFFECTS OF HUMAN BEHAVIOR ON INHALATION EXPOSURE TO RADON VOLATILIZED FROM DOMESTIC WATER USES Harry E. Rector and Charles R Wilkes GEOMET Technologies, Inc. Germantown, MD Nicholas J. Giardino Armstrong Laboratory, Office of Environmental Medicine and Health, United States Air Force Brooks AFB, TX ABSTRACT Volatilization from domestic water uses can produce significant indoor radon concentrations in areas affected by radium-bearing aquifers. While radon levels in the water supply play an important role in determining exposure, the ultimate magnitude of such exposures also depends on human activities to operate various components of the water system and to situate members of the household in the scenario. In the work reported here, human activity data was utilized to establish spatial and temporal patterns of domestic water use and to identify locations of household members throughout a typical daily schedule. The activity data along with appliance-specific radon release rates, airflow data, and physical property data was applied to an indoor air quality model to evaluate patterns of concentration and exposure arising from typical scenarios. Indoor concentrations of radon and radon decay products in a sample home and resulting inhalation dose were computed for specific individuals and families of individuals to isolate the effects of direct exposure (i.e., occupant exposed to radon from selfdirected water use) versus co-exposure (i.e., occupant exposed to radon from water use directed by someone else in the household). It was found that the shower delivers the potential dose at the highest rate. INTRODUCTION Volatilization from domestic water uses can produce significant indoor radon concentrations in areas affected by radium-bearing aquifers. While radon levels in the water supply play an important role in determining exposure, the ultimate magnitude of such exposures also depends on human activities to operate components of the water system and to situate members of the household in the scenario. In the work reported here, human activity data was utilized to establish spatial and temporal patterns of domestic water use and to identify locations of household members throughout a typical daily schedule. The activity data along with appliance-specific radon release rates, airflow data, and physical property data was applied to an indoor air quality model to evaluate patterns of concentration and exposure arising from typical scenarios. Indoor concentrations of radon and radon decay products in a sample home and resulting inhalation dose were computed for specific individuals and families of individuals to isolate the effects of direct exposure (i.e., occupant exposed to radon from self-directed water use) versus coexposure (i.e., occupant exposed to radon from water use directed by someone else in the household). It was found that the shower delivers the potential dose at the highest rate. MODEL FRAMEWORK The indoor air qualitylexposure model used in this study is based on earlier work to evaluate the role of human activity patterns and other indoor environment factors in determining inhalation exposure to a variety of chemicals volatilized from domestic and municipal water supplies (Wilkes et a]., 1992). Under support from the U.S. Air Force, the model framework is undergoing expansion to potentially incorporate comprehensive depictions of source processes, reversibleiirreversible sinks, and pharmacokiietics. 1996 International Radon Symposium 1-8.1

The model implements a deterministic, pollutant mass-balance calculation for indoor air pollutant concentrations. The building is represented by a collection of well-mixed compartments interconnected by flow elements. The compartments are typically determined by physical boundaries in the building. The mass-balance for compartment i is given by: where i and j are compartment numbers, Vi is the volume in compartment i, C, is the air concentration in compartment i, t is time, Ql, is the flowate from compartment i to compartment j, and \c is one or more characteristic first-order processes (e.g., radioactive decay, deposition). The air contaminants are transported between compartments by the air flows. The air flows may be constant, based on short-term conditions of interest. The air flows may also be variable, responding to changing conditions in the model, such as the opening and closing of windows or doors, or operation of exhaust fans, or responding to changing environmental conditions, such as the ambient wind speed or temperature. Equation 1 is solved for each compartment using the fourth-order Runge-Kutta method (Press et a!., 1988) for temporal integration. Volatilization of radon from the water supply during a given water use is calculated from two-film gas transfer theory (see Giardino et al., 1990): where S is the volatilization source term (pci mid ), CA is the radon concentration in the air (pci L"), Cw is the radon concentration in the water prior to volatilization (pci L ), H is the dimensionless Henry's constant (the equilibrium ratio, CAI&), fv is the dimensionless mass-transfer coefficient (equal to the fractional volatilization when Ci is zero), and Fw is the flowrate of the water (L min"' ). Each of the process parameters is assumed constant for a specific water use. The model solves for the relevant air concentration (CA) at each time step. The mass transfer coefficient is a function of the characteristics of the volatilizing species and the water use such as the drop size distribution, residence time, flowrate, and water temperature. The relevant chemical characteristics that affect volatilization include the solubility and vapor pressure, which determine H and diffusion properties. Where appropriate, the effect of volatilization from the pool of water around the drain is also included in the source parameterization. A single-story, five-room house (Figure 1) was defined to provide a realistic (though not necessarily representative) basis for modeling scenarios. The air flow balance provides for an air exchange rate of 0.5 air exchanges per hour; which corresponds to current estimates of the national average (Koontz and Rector, 1995). Separate air flow regimes were defined to incorporate effects of closing the bathroom door and to allow for operation of the bath exhaust fan while the door was closed. Deposition of radon progeny was described using a simple first-order removal term (1.5 h" ) derived from experimental work in research houses (Rector et al. 1985). For these model runs, the water supply was assigned a radon concentration of 10,000 pci L"'. Contributions from soil gas entry, emanation from building materials, and outdoor air concentrations were arbitrarily set to zero in order to isolate the effects of the water supply. The values for the volatilization mass-transfer coefficients presented in Table 1 are based on qualitative estimates of the residence time in which the water is in contact with the surrounding air as well as values reported in the literature for radon volatilization (see, for example Giardino and Hageman 1996, Wilkes et al. 1996, Nazaroff et al. 1988). The two different values for Henry's constant are for hot (40Â C and cold (25' C) water uses. The volume, flowrate, duration, and frequency data for water consumption used as input for the model have been derived from a U.S. 1996 International Radon Symposium I - 8.2

Department of Housing and Urban Development survey of 200 households (U.S.DHUD, 1984; Marshall, 1990. Each event uses the average amount of water for that event type reported in the survey, but the number of events have been adjusted to the nearest whole number. Volatilization from the toilet was parameterized separately for short term effects of flushing and "standby" losses between uses. A two minute burst representing the turbulent flow conditions that occur during the flush utilizes half of the total water volume delivered for each flush. The remaining volume was converted to a continuous flow spread throughout the day to represent the volatilization from the water standing in the bowl and tank between flushes. Activity patterns were defined for a hypothetical family consisting of of two adults and one child (Figure 2). Adult 1 works outside of the home, and is away between 7:45 am and 5:30 pm. Adult 2 has primary child care responsibility, and performs associated tasks as well as other household tasks. Adult 2 and the child are home for the majority of the day. The "standard day" arising from the sourcelactivity scenario was modeled for two consequitive days to establish cany-through from one day to the next. Analysis and interpretation focused on the second 24 hour period. RESULTS AND DISCUSSION Large temporal and spatial variations occur in the radon profiles of the modeled home. As shown in Figure 3, radon concentrations in a given source room rise quickly but elevated levels do not persist for long after the water use ends. Highest concentrations (approaching 60 pci L" ) were produced in the shower and in the bathroom (approaching 20 pci L" ). This impact was largely confined to the bathroom, however, by keeping the door closed and operating the exhaust fan. Laundry operation and, to a lesser extent, water use in the kitchen, on the other hand, raised concentrations throughout the house. Room-to-room variations are somewhat smaller for 24-hour average radon concentrations (Table 2), varying by about a factor of six from the shower (4.1 pci L" ) to the living room and bedroom areas (0.7 pci L" ). The volumeweighted average radon concentration for this scenario was 1. I pci L"', corresponding well with generally accepted rules-of-thumb for the impact of waterborne radon. Radon progeny levels showed less room-to-room variations, ranging from 0.003 WL in the living room and bedroom areas to 0.01 WL in the bathroom. Average concentrations in locations that would be selected for standard monitoring were significantly lower than the averages accumulated by family members as they moved from place to place. The time-averaged radon exposure for Adult 2 is twice that implied by concentrations in the living room. Time-averaged exposure to radon progeny, on the other hand is only about 10 percent higher than 24-hour averages in the living room would suggest; this is probably due to the relatively slow ingrowth of radon progeny and the abbreviated occupancy. Exposures for the child or for Adult 1 are significantly smaller. Adult 1 spends just over 14 hours in the home and, except for showering, spends relatively little time in the proximity of waterborne sources. Adult 2, on the other hand, spends nearly 20 hours in the in the home and performs most of the water-using tasks, such as the laundry. The equivalent exposure of the child is lower even though the time spent in the house is the same as for Adult 2. A large share of the difference is due to the morning shower taken by Adult 2. Also, the effect of Adult 2 taking a shower immediately after Adult 1 has taken one can be seen in Figure 3. Even though both adults take showers of equal length, Adult 2 is exposured to significantly higher concentrations due to residual concentrations from the first shower. The showering activity accounts for approximately 25 percent of the radon exposure while occupying only about 2 percent of the time spent in the home. CONCLUSIONS Physical characteristics of radon volatilization from water use and room-to-room transport, as well as human activity and locations of sources are essential elements of residential exposure in regions where water supplies pose concerns. In addition, it is necessary to consider location and water use characteristics of the occupants when evaluating the effect of a contaminated water supply on inhalation exposure. 1996 International Radon Symposium I - 8.3

REFERENCES Giardino, N.J., and Hageman, J.P. (1996) "Pilot Study of Radon Volatilization from Showers with Implications for Dose." Environmental Science & Technology. vol. 30, no. 4, pp 1242-44. Giardino N.J., Gumerman E., Andelman J.B., Wilkes C.R., and Small M.J. (1990) Real-Time Air Measurements of Trichloroethylene in Domestic Bathrooms using Contaminated Water. Proceedings- The Fifth International Conference on Indoor Air Quality and Climate, Toronto, July 1990, Vol. 2 p707-7 12. Koontz, M.D., and Rector, H.E. (1995). Estimation of Distributions for Residential Air Exchange Rates. GEOMET Report No. 1E-2603. Prepared for U.S. Environmental Protection Agency, Office of Pollution Prevention and Toxics, Washington, D.C. Marshall J. (1990) In-House Water Use and Human Activity Patterns: Input Data for MAVRIQ. Master's Thesis, Graduate School of Public Health, University of Pittsburgh, Pittsburgh PA, 15261. Press W.H., Flannery B.P., Teukolsky S.A., and Vetterling W.T. (1988) Numerical Recipes in C, Cambridge University Press, New York, NY. Rector, H.E., Koontz, M.D., Cade, D.R., and Nagda, N.L. (1985). Impact of Energy Conservation Measures on Radon and Radon Progeny Concentrations: A Controlled Study. ASHRAE Transactions, Vol91, Part 2, pp 1954-62. U.S. Department of Housing and Urban Development (1984) Residential Water Conservation Projects. Contract H-5230. Wilkes, C.R., Small, M.J., Davidson, C.I., and Andelman, J.B. (1996). "Modeling The Effects Of Water Usage And Co Behavior On Inhalation Exposures To Contaminants Volatilized From Household Water." accepted for publication by the Journal of Exposure Analysis and Environmental Epidemiology. Wilkes, C.R., Small, M.J., Andelman, J.B., Giardino, N.J., and Marshall, J. (1992). "Inhalation exposure model for volatile chemicals from indoor uses of water." Atmospheric Environment. 26A(12): 2227-2236. 1996 International Radon Symposium I - 8.4

Living I 4 5 Bath 13 m3 4 6 Shower 2 0 m2 Exfiltration (m3 h-i ) Infiltration (m3 h-i ) Q,o = 14.1 QOI = 28.7 QZo= 9.8 Qo2 = 20.4 Q30 = 36.2 Qo3-25.0 167.51- Q40 = 36.3 Qo4 = 13.5 (2% = 2.4 [44.9]* Qo5 = 1.2 Qeo = 0.0 QC6 = 0.0 Bracketed values denote flows while bathroom door is closed and exhaust fan operates Interzonal Airflows (m3 h-i ) Q,3 = 67.5 Q31 = 52.9 Q23= 41.1 Q3? = 30.5 Q43 = 27.2 Q34 = 50.0 QS3 = 15.1 [4.2JU Q3c = 16.3 [47.9]* Qs6 = 25.0 Qe5 = 25.0 Figure 1 Flow Balance for Model Scenarios 1996 International Radon Symposium I - 8.5

Table I Mass-Transfer Coefficients for Modeled Sources \V;iIcr Source 3;1111 I 5 Sll id (1 I (1 71) 1'0ikl Flush 4 411 -> fl 1 1 D O S~;iiidb> Coii~iiii~o~is ot)o. hsii\\;islicr I) 011 3 1 11 I 0.YO LOCATIUN LEGEND EXTERIOR LmA HALLIENTRY SHOWER LIVING ROOM KITCHEN BEDROOM.-. BATHROOM CHILD ADULT ADULT Figure 2. Daily Household Activity Patterns. 1996 International Radon Symposium I - 8.6

Table 2. Summary of Model Results Modeled Concentrations (24-hour Average) Living Bedroom Utility Kitchen Bath Shower Room Radon 0.7 0.7 1.1 1.1 3.4 4.1 (p~il") Radon Progeny 0.29 (WL x 100) Radon (pci~") Radon Progeny (WL x 100) Modeled Exposures (24-hour Average) Adult 1 Adult 2 Child 1 1996 International Radon Symposium I - 8.7

Shower 20 - -. 10 Bath 0. 1...... Kitchen 0 10 0 Bedroom 10..-.. - 0 Living Room 0 6 12 18 24 Time, Hours Figure 3. Modeled Radon Concentrations. 8 1996 International Radon Symposium I - 8.8