CORESTA RECOMMENDED METHOD N 61

Similar documents
Chem 321 Lecture 23 - Liquid Chromatography 11/19/13

Agilent MetaCarb Ca PLUS Carbohydrate Column Ca ++ Form User Manual Part No. A5205

Polyvidone Polyvinylpyrrolidone H 2 C H C N

Protein-Pak Hi Res HIC Column and HIC Protein Standard

ISO 6496 INTERNATIONAL STANDARD. Animal feeding stuffs Determination of moisture and other volatile matter content

INTERNATIONAL PHARMACOPOEIA MONOGRAPH ON ARTEMETHER AND LUMEFANTRINE CAPSULES REVISED DRAFT FOR DISCUSSION

STANDARD OPERATING PROCEDURES

Method 6.1 Boiling house products: Brix, pol and purity

Method 5.2 Syrup and remelt: Brix, NIR pol and purity

Method 5.1 Syrup and remelt: Brix, pol and purity

CHROMATOGRAPHY/MASS SPECTROMETRY

Standard Operating Procedure Title: Operation and Calibration of Sievers 820 TOC Analyser

Preparative HPLC is still the

Certified Reference Material - Certificate of Analysis

METHOD 25D - DETERMINATION OF THE VOLATILE ORGANIC CONCENTRATION OF WASTE SAMPLES. NOTE: Performance of this method should not be

Fines content. SCAN-CM 66:05 Accepted Mechanical and chemical pulps

3. Close the bottom end of the column and apply the packing device on top. Pump water through the upper adaptor to remove air.

Size Exclusion Chromatography of Biosimilar and Innovator Insulin Using the Agilent AdvanceBio SEC column

Technical Report Electronic Cigarette Aerosol Parameters Study

Technical Report Electronic Cigarette Aerosol Parameters Study

Capillary Electrophoresis of Proteins

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Quality-by-Design-Based Method Development Using an Agilent 1290 Infinity II LC

Fast Preparative Column Liquid Chromatography (PCLC)

Physical Stability of a Silica- Based Size Exclusion Column for Antibody Analysis

Determination of Adenovirus pviii (31K) Concentration for Estimation of the Empty Capsid Concentration of the Adenovirus Reference Material (ARM)

Canine Cortisol(COR)ELISA Kit

Agilent AdvanceBio SEC Columns for Aggregate Analysis: Instrument Compatibility

Determination of organochlorine pesticide residues in eggs by gel-permeation chromatography (GPC) cleanup and GC-ECD

DRAFT EAST AFRICAN STANDARD

Human IgG Antigen ELISA Kit

Protocol for Quantitative Determination of Residual Solvents in Cannabis Concentrates Prepared by: Amanda Rigdon, May 23 rd, 2016

mab Titer Analysis with the Agilent Bio-Monolith Protein A Column

Approved for NPDES (Editorial Revision 1978) Silica, Dissolved (Colorimetric)

Provläsningsexemplar / Preview. First edition

HPLC METHODOLOGY MANUAL

EtG / EtS Analysis UCT INNOVATION THROUGH CHEMISTRY FORENSICS

Human IL-1 alpha ELISA Kit

VICH Topic GL2 (Validation: Methodology) GUIDELINE ON VALIDATION OF ANALYTICAL PROCEDURES: METHODOLOGY

Mouse Factor XII Total ELISA Kit

Ultrahydrogel Columns

MS Certified Vials. Pre-cleaned and certified vials for mass spectrometry

ImmuLux Human IL-6 Fluorescent ELISA Kit

HYDROCARBONS, BP C 1500

ISO INTERNATIONAL STANDARD. Petroleum products Determination of sulfur content Wavelength-dispersive X-ray fluorescence spectrometry

RP-HPLC METHOD FOR QUANTITATIVE ESTIMATION OF GLATIRAMER ACETATE FOR INJECTION IN PHARMACEUTICAL DOSAGE FORMS

BUREAU OF INDIAN STANDARDS

Formulas: See Table 1 MW: Table 1 CAS: Table 1 RTECS: Table 1. METHOD: 2555, Issue 1 EVALUATION: PARTIAL Issue 1: 15 March 2003

Method 4.2 Filter cake, filter feed and filtrate: Brix, NIR pol and purity

ISO 3093 INTERNATIONAL STANDARD

RayBio Human Caspase-3 ELISA Kit

SASTA Method 3.1: Brix, pol and purity

Disulfide Linkage Analysis of IgG1 using an Agilent 1260 Infinity Bio inert LC System with an Agilent ZORBAX RRHD Diphenyl sub 2 µm Column

RayBio Custom ELISA Kit

BÜCHI Labortechnik AG

Practical guidance for switching between anion and cation analysis systems

Bovine Prostaglandin E2 (PG-E2) ELISA Kit

Volatile organic compounds Water No CAS Number assigned

Total Dissolved Solids Dried at 180ºC. Total Volatile Dissolved Solids at 550 C

Application Note. Author. Abstract. Biopharmaceuticals. Verified for Agilent 1260 Infinity II LC Bio-inert System. Sonja Schneider

RayBio Rat IL-6 ELISA Kit (For Lysates)

Determination of Oxalate and Other Anions in Bayer Liquor Using Ion Chromatography

Volatile Organic Compounds in Solids PBM

SensoLyte Anti-alpha-Synuclein Quantitative ELISA Kit (Human/Mouse/Rat) *Colorimetric*

PROCESSED EUCHEUMA SEAWEED

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology

Supporting Information. Temperature-controlled Phase-transfer Catalysis for Ethylene. Glycol Production from Cellulose

Ti-Pure TITANIUM DIOXIDE. CONCENTRATED ACID SOLUBILITY OF TiO 2 METHOD: T WP

Rat α-melanocyte stimulating hormone (α-msh) ELISA Kit

Analysis of 16 Pesticide Residues in Broccoli Using CarbonX dspe QuEChERS AOAC Kits Using GC/MS

Porcine IgM (Immunoglobulin M) ELISA Kit

Performance of the Sievers 500 RL On-Line TOC Analyzer

Overview of preparative HPLC. Analytical Technologies Limited

SCION GC Series. The Gas Chromatographers Choice for Separations

SASTA Method 3.2: Brix, NIR pol and purity

Quantitative determination of residual 2-(2-chloroethoxy) ethanol (CEE) in quetiapine fumarate by gas chromatogaraphy

Validated Stability-indicating assay method for determination of Ilaprazole in bulk drug and tablets by high performance liquid chromatography

Technical Overview. Author. Abstract. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Municipal Wastewater. Introduction: Sample Matrix: Wastewater; various locations along the sewage treatment process.

R R Innovation Way P/N SECKIT-7830 Newark, DE 19711, USA Tel: Fax: Website: Published in November 2013

Fast mass transfer Fast separations High throughput and improved productivity Long column lifetime Outstanding reproducibility Low carryover

Mouse Luteinizing Hormone (LH) ELISA

Product datasheet. Storage recommendations Store the kit at 2-8 C. The kit is stable for a period of up to 3 months from the date of receipt.

HUMAN CONNECTIVE TISSUE GROWTH FACTOR (CTGF) ELISA KIT

Bovine prolactin/luteotropic hormone (PRL/LTH) ELISA Kit

AFFINITY HIS-TAG PURIFICATION

Determination of Monocrotophos, Diazinon, Malathion, EPN, and Methamidaphos from Aqueous Samples Using Atlantic HLB SPE Disks

Calcium and Vitamin D with Minerals Samples: Standard solution and System suitability Tablets

2. Crystallization. A. Background

ISO INTERNATIONAL STANDARD. Paper, board and pulps Determination of total magnesium, total calcium, total manganese, total iron and total copper

Gas Chromatography Assignment Chem 543/443

Top Tips for Conducting DMR-QA Analyses Waters Corporation 1

A2LA. R231 Specific Requirements: Threat Agent Testing Laboratory Accreditation Program. December 6, 2017

Econo-Pac High Capacity Ion Exchange Cartridges, 5 ml Instruction Manual. Catalog Numbers , ,

HIC as a Complementary, Confirmatory Tool to SEC for the Analysis of mab Aggregates

APPLICATION NOTE. UOP : Analysis of Trace CO and CO 2 in bulk H 2 and Light Gaseous Hydrocarbons by GC

A Modular Preparative HPLC System for the Isolation of Puerarin from Kudzu Root Extracts

HUMAN CONNECTIVE TISSUE GROWTH FACTOR (CTGF) ELISA KIT

Separation and Quantitation of a Mixture of Alcohols by Gas Chromatography

Human placenta lactogen (HPL) ELISA Kit

Transcription:

CORESTA RECOMMENDED METHOD N 61 DETERMINATION OF 1,2-PROPYLENE GLYCOL, GLYCEROL AND SORBITOL IN TOBACCO AND TOBACCO PRODUCTS BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC) (July 2015) 0. INTRODUCTION The CORESTA Routine Analytical Chemistry (RAC) Sub-Group studied various widely-used procedures for the determination of 1,2-propylene glycol (PG), glycerol (GLY) and sorbitol (SOR) by high performance liquid chromatography (HPLC) in order to adopt one of them as the CORESTA Recommended Method (CRM). Studies were carried out by the RAC Sub- Group between 1993 and 1999 to evaluate sample preparation, extraction and analysis parameters. This CRM was originally developed with tobacco and did not include smokeless tobacco products. Therefore, in 2012, the CORESTA Smokeless Tobacco Sub-Group (STS) conducted a collaborative study for the determination of PG and GLY in smokeless tobacco products in order to expand the scope of this CRM. 1. FIELD OF APPLICATION This method is applicable to tobacco and tobacco products, including smokeless tobacco and cigarette filler. The method is applicable to PG and GLY concentrations ranging at least from a mass fraction of 0,3 to 5,0. 2. PRINCIPLE The sample is extracted into water and filtered. The filtrate is analysed by HPLC with refractive index detection. Results are reported as percent (weight/weight). Note: During the joint experiments equivalent results were obtained for the extraction with 0,01M NaOH which inhibited the inversion of sucrose. This can be useful for a possible simultaneous determination of sugars. 3. REFERENCES 3.1. CORESTA Recommended Method N 56, Determination of Water in Tobacco and Tobacco Products by Karl Fischer Method. 3.2. CORESTA Recommended Method N 57, Determination of Water in Tobacco and Tobacco Products by Gas Chromatographic Analysis. 3.3. CORESTA Technical Report on 2007 Joint Experiments to Update Repeatability and Reproducibility Statistics for: CORESTA Recommended Method N 60, Determination of 1,2-Propylene Glycol and Glycerol in Tobacco Products by Gas Chromatography. CORESTA Recommended Method N 61, Determination of 1,2-Propylene Glycol and Glycerol in Tobacco Products by High Performance Liquid Chromatography. CRM No. 61 July 2015 Page 1/13

3.4 CORESTA Smokeless Tobacco Sub-Group Technical Report: 2012 Collaborative Study on Humectants. 4. APPARATUS It is essential to clean all glassware very thoroughly before use. All volumetric flasks and pipettes shall comply with class A. 4.1. HPLC-equipment Liquid chromatograph with pump, autosampler, column oven and refractive index detector with thermostatic cell. A recorder, integrator or chromatographic data system capable of integrating chromatograms to obtain peak area. See Manufacturer s instructions for operation. 4.2. Orbital shaker capable of about 250 275 rpm or a wrist action shaker. 4.3. General laboratory equipment necessary for the preparation of samples, standards and reagents. 5. REAGENTS 5.1. Water, double distilled or of other equivalent quality (conductivity less than 0,2 µs/cm). 5.2. Ethylene diamine tetra acetic acid, calcium-disodium salt (Ca,Na-EDTA). 5.3. 1,2-propylene glycol, analytical grade, minimum purity 99,5, for the preparation of standard solutions. 5.4. Glycerol, analytical grade, minimum purity 99,5, for the preparation of standard solutions (store in a desiccator). 5.5. D(-)-sorbitol, minimum purity 99,5, for the preparation of standard solutions (store in a desiccator). 5.6. Celite Hyflo Super Cel (silica, particle size less than 5 µm). 6. STANDARDS Prepare a stock solution by dissolving PG, GLY and SOR in water. Prepare working standards by diluting the stock solution with water as described in 6.2 with concentrations covering the range expected to be found in the samples (usually 0,3 to 5,0 ). 6.1. Stock solution of PG, GLY and SOR. Weigh, to the nearest 0,0001 g, approximately 0,2 g of each humectant in a 200 ml volumetric flask. Dilute to volume with water and shake well to mix. Calculate the exact concentration of the stock solution and record. 6.2. Working standards. From the stock solution produce a series of at least five working standards to cover the range of expected results to be found in the samples. For example, when sample humectant concentration range from 1,0 to 2,5, prepare standards ranging from 0,5 to 3,0 humectants. Transfer the aliquots of the stock solution into separate volumetric flasks, dilute to volume with water and shake well to mix. Calculate the exact concentrations for each standard and record. See Table 1 for suggested dilutions. Note: A blank with no added PG, GLY and SOR may be used in the calibration curve. CRM No. 61 July 2015 Page 2/13

Table 1 Suggested dilutions for working standards (related to 100 ml volumetric flask) Standard number Volume of stock solution ml Concentration of PG, GLY and SOR mg/ml Concentration 2,5 g sample 1 2 0,02 0,08 2 5 0,05 0,20 3 25 0,25 1,00 4 50 0,50 2,00 5 75 0,75 3,00 6 100 1,00 4,00 All solutions shall be stored in a cool and dark place (nominally 5 C). conditions the solutions are stable for 12 days. Under these 7.1. HPLC analysis 7. PROCEDURE Set up and operate the liquid chromatograph according to the Manufacturer s instructions. Ensure that the peaks for PG, GLY, SOR and other peaks of interest (e.g. sugars) are well resolved. 7.1.1. Suitable HPLC conditions Mobile phase: water + 50 mg/l calcium-disodium EDTA Flow rate: 0,5 ml/min Oven temperature: 80 C Injection volume: 20 µl Column: calcium salt of sulfonated Styrenedivinylbenzene Copolymer e.g. Sugar Pak I TM (Waters) 1 30 cm x 6,5 mm i.d. (see Annex A for details of column care); a guard column with the same packing is recommended Detector cell: cell temperature 40 C The performance of the column should be sufficient to achieve a satisfactory separation of all components similar to that given in the specimen chromatogram (see figure 2). See figure 1 and 2 for chromatograms of a standard and a tobacco extract respectively. 7.2. Calibration of the HPLC Inject 20 µl of each working standard into the HPLC. Record peak heights of PG, GLY and SOR. Plot the PG, GLY and SOR peak heights versus the concentrations on a graph and calculate a linear regression equation from these data. The graph should be linear and the regression equation line should not be forced through the origin. The minimum correlation coefficient, R 2, should be 0,99. Perform this full calibration procedure when analyses are performed. In addition, inject an aliquot of an 1 Sugar Pak I is a trade name of a product supplied by Waters. This information is given for the convenience of users of this Recommended Method and does not constitute an endorsement by CORESTA of this product. Equivalent products may be used if they can be shown to lead to the same result. CRM No. 61 July 2015 Page 3/13

intermediate concentration standard after every 20 sample determinations. If the calculated concentration for this solution differs more than 5 from the original value, repeat the full calibration procedure and, as appropriate, reanalyse samples associated with that calibration. 7.3. Sample Preparation Tobacco and tobacco product samples may be analysed as loose cut samples or may be ground. Note 1: Drying and/or grinding of samples that contain PG will cause a significant loss of this compound due to its volatility. Note 2: GLY and SOR do not distribute homogeneously in tobacco. This should be taken into account when determining the number of replicates per sample. Note 3: Secondary reference material or monitors (cased tobacco containing PG, GLY and SOR ground to pass a 1 mm sieve) are used in some laboratories as an additional check of the total analysis process. Typically monitors are prepared according to 7.3 and randomly placed throughout the run. Statistical process control (SPC) is then applied to evaluate these data which may include plotting the mean, range, or standard deviation on control charts, analysing the pattern, and taking action in response to an out of control condition. Weigh, to the nearest 0,01 g, approximately 2,5 g of sample into a 250 ml Erlenmeyer flask. Add 100 ml water and stopper the flask. Shake vigorously at high speed (see 4.2) for 30 minutes. Filter extract in small portions under vacuum through a bed of hyflo supercel (3-4 g) supported on a filter paper in a Buchner funnel. Discard the first two or three volumes of filtrate and collect the remaining filtrate. Transfer an aliquot of the extract into an autosampler vial and cap. 7.4. Measurement and calculation of humectant content of samples Inject a 20 µl aliquot of the extract into a HPLC using the conditions appropriate for the HPLC and column utilised. Record the peak heights of PG, GLY and SOR obtained from the chromatogram. The amount of humectants is determined by the external standard method using the calibration curve produced in 7.2. Ensure that the values of the sample extract lie within the ranges of the standards prepared in section 6.2. The content of humectant (PG, GLY or SOR), in the tobacco sample, expressed as a percentage by weight, is given by the equation: c * V * 100 w * 1000 where c V w is the concentration of humectant (PG, GLY or SOR) obtained from the calibration curve, in milligrams per millilitre is the volume of extraction solution, in millilitres (normally 100 millilitres) is the weight of tobacco sample, in grams CRM No. 61 July 2015 Page 4/13

8. REPEATABILITY AND REPRODUCIBILITY The data presented below are from three large international studies. The first two studies conducted in 1999 and 2007 included tobacco while the third study conducted in 2012 included smokeless tobacco products. An international collaborative study performed by CORESTA involving 8 laboratories and 4 samples was conducted in 1999 and analysed according to ISO 5725 guidelines. Only 6 of the participating laboratories provided sorbitol data. The data from the laboratories contained 3 outliers for the determination of glycerol in cut rag and 2 outliers for the determination of sorbitol in cut rag. The outliers were not included in the calculation of the repeatability standard deviations and the reproducibility standard deviations. Data from this collaborative study (with a limited number of participants) showed that when tobacco samples are analysed by this method, the following values for repeatability limit (r) and reproducibility limit (R) are obtained. The influence of analysing cut tobacco samples instead of ground tobacco samples may be estimated by the corresponding values of r and R. The difference between two average results (of which each is the average of a double analysis) found on matched tobacco samples by one operator using the same apparatus within shortest feasible time interval will exceed the repeatability limit (r) on average not more than once in 20 cases in the normal and correct operation of the method. Single results (which each is the average of a double analysis) on matched tobacco samples reported by two laboratories will differ by more than the reproducibility limit (R) on average not more than once in 20 cases in the normal and correct operation of the method. Data analysis for the 1999 study gave the estimates as summarized in tables 2-7 Table 2 1999 Study: 1,2-Propylene glycol cut tobacco samples Mean concentration of 1,2 propylene glycol Repeatability limit r Reproducibility limit R 0,585 0,120 0,530 1,568 0,062 0,315 2,724 0,208 0,825 4,723 0,153 0,480 Table 3 1999 Study: Glycerol cut tobacco samples Mean concentration of Glycerol Repeatability limit r Reproducibility limit R 0,223 0,048 0,448 1,244 0,053 0,311 2,442 0,106 0,862 4,396 0,181 1,369 CRM No. 61 July 2015 Page 5/13

Table 4 1999 Study: Sorbitol cut tobacco samples Mean concentration of Sorbitol Repeatability limit r Reproducibility limit R 0,079 0,051 0,179 1,003 0,113 0,294 1,971 0,167 0,195 2,709 0,193 0,452 Table 5 1999 Study: 1,2-Propylene glycol ground tobacco samples Mean concentration of 1,2 propylene glycol Repeatability limit r Reproducibility limit R 0,574 0,054 0,555 1,596 0,067 0,276 2,669 0,102 0,666 4,554 0,096 0,450 Table 6 1999 Study: Glycerol ground tobacco samples Mean concentration of Glycerol Repeatability limit r Reproducibility limit R 0,167 0,039 0,326 1,211 0,090 0,214 2,367 0,095 0,810 4,281 0,108 0,572 Table 7 1999 Study: Sorbitol ground tobacco samples Mean concentration of Sorbitol Repeatability limit r Reproducibility limit R 0,097 0,022 0,207 1,028 0,080 0,236 1,943 0,118 0,323 2,620 0,169 0,206 During 2007, the CORESTA Scientific Commission requested the RAC Sub-Group carry out a second collaborative study to investigate whether the repeatability (r) & reproducibility (R) values quoted in the methods were still relevant or could be improved. The r and R statistics published in CRMs 60 and 61 were relatively large. Sample nonhomogeneity was suspected to be a key contributor to the observed methods variability. CRM No. 61 July 2015 Page 6/13

Eight tobacco samples were dispatched to 19 laboratories for the second collaborative study. These samples consisted of four pouches of loose cut tobacco and four pouches of finely ground (ground to pass through a 1mm sieve) and homogenized tobacco from the same population as the loose cut tobacco samples. As non-homogeneity was suspected to be a key contributor to the large observed r and big R statistics in the original study, for this study every effort was made to prepare the samples as homogeneously as possible. Duplicate preparations of each sample pouch were made with two injections per sample preparation, consistent with the original studies. Results were reported on an as received basis. Table 8 CORESTA Collaborative Study of 1,2-Propylene Glycol and Glycerol Measurements Comparison of 1999 and 2007 Study Performance Measures Mean () Propylene Glycol in Cut Loose Tobacco - HPLC Method* 1999 Study 2007 Study Sample 1 Sample 2 Sample 3 Sample 4 Sample 1 Sample 2 Sample 3 Sample 4 0,585 1,568 2,724 4,723 0,439 1,251 2,103 3,573 r 0,120 0,062 0,208 0,153 0,077 0,071 0,090 0,174 R 0,530 0,315 0,825 0,48 0,358 0,408 0,503 0,307 Mean () Glycerol in Cut Loose Tobacco - HPLC Method* 1999 Study 2007 Study Sample 1 Sample 2 Sample 3 Sample 4 Sample 1 Sample 2 Sample 3 Sample 4 0,223 1,244 2,442 4,396 0,560 1,413 2,324 3,707 r 0,048 0,053 0,106 0,181 0,035 0,051 0,064 0,208 R 0,448 0,311 0,862 1,369 0,129 0,196 0,217 0,450 Mean () Propylene Glycol in Ground Tobacco - HPLC Method 1999 Study 2007 Study Sample 1 Sample 2 Sample 3 Sample 4 Sample 1 Sample 2 Sample 3 Sample 4 0,574 1,596 2,669 4,554 0,424 1,236 2,072 3,435 r 0,054 0,067 0,102 0,096 0,050 0,054 0,093 0,075 R 0,555 0,276 0,666 0,450 0,230 0,390 0,469 0,204 Mean () Glycerol in Ground Tobacco - HPLC Method* 1999 Study 2007 Study Sample 1 Sample 2 Sample 3 Sample 4 Sample 1 Sample 2 Sample 3 Sample 4 0,167 1,211 2,367 4,281 0,558 1,425 2,307 3,555 r 0,039 0,090 0,095 0,108 0,037 0,059 0,023 0,070 R 0,328 0,214 0,810 0,572 0,131 0,155 0,245 0,369 CRM No. 61 July 2015 Page 7/13

*Note: r and R statistics for the HPLC methods are based on a very small number of laboratories, eight in the original study and four in this study with Lab 15 excluded. The large r and R observed in the original 1999 study was hypothesised to result from nonhomogeneity of the test samples and not as a result of the analytical methodology or laboratory competence. In the 2007 study therefore, extreme care was taken to prepare homogeneous test samples and as can be seen a significant improvement r and R was obtained, thus proving sample homogeneity to be a key parameter in result consistency. Details of the sample preparation to improve homogeneity can be found in the technical report (3.3.) available from the CORESTA Secretariat and on the CORESTA web site. In 2012, the CORESTA Smokeless Tobacco Sub-Group conducted the third collaborative study for the determination of propylene glycol and glycerol in smokeless tobacco products using CRM Nº 61. The five products included in this study are described in the table below. Not all samples contained both humectants, Table 9 Sample Descriptions for 2012 CORESTA Collaborative Study Sample Sample Description Contains Propylene Glycol Contains Glycerol Sample A American style moist snuff no Sample B American style loose leaf chewing tobacco Sample C Swedish style snus - loose tobacco CRP 1 Swedish style snus pouch no CRP 4 American style loose leaf chewing tobacco no The overall level of variability for smokeless tobacco products seen in this study was similar to the 2007 RAC study for ground tobacco samples. The results for the 2012 study showed similar intra-laboratory and inter-laboratory variability for both tobacco and smokeless tobacco products which indicates that this CRM is appropriate for the analysis of both tobacco and smokeless tobacco products. No evidence was found for any smokeless tobacco related method interferences. The r and R results for the 2012 study are presented below: CRM No. 61 July 2015 Page 8/13

Table 10 2012 CORESTA Collaborative Study for the determination of Propylene Glycol and Glycerol in Smokeless Tobacco Products Sample Number of Labs 1 Mean () r R r R Propylene Glycol Glycerol Sample A 7 1.064 0.0640 0.117 6.0 11.0 Sample B 7 0.809 0.0350 0.130 4.3 16.1 Sample C 7 3.489 0.0560 0.286 1.6 8.2 CRP 1 7 2.751 0.2780 0.475 10.1 17.3 CRP 4 NA 2 NA 2 -- -- -- -- Sample A NA 2 NA 2 -- -- -- -- Sample B 7 2.504 0.0510 0.563 2.0 22.5 Sample C 6 2.855 0.0260 0.656 0.9 23.0 CRP 1 NA 2 NA 2 -- -- -- -- CRP 4 7 4.004 0.2650 0.980 6.6 24.5 1. The number of laboratory data sets remaining after removal of outliers (Grubbs test, Cochran s test). 2. The sample did not contain the humectant listed. 9. TEST REPORT The test report shall give concentration of humectant in (weight/weight) and shall include all conditions which may affect the result (e.g. grinding, drying and (if corrected to dry weight basis) method for determination of moisture content). It shall also give all details necessary for the identification of the sample. CRM No. 61 July 2015 Page 9/13

Figure 1 Example of a chromatogram for a humectant standard CRM No. 61 July 2015 Page 10/13

Figure 2 Example of a chromatogram for a tobacco extract CRM No. 61 July 2015 Page 11/13

Column care ANNEX A (informative) Experience has shown that the tobacco matrix can lead to a contamination of some parts of the HPLC system. To ensure good resolution and chromatographic conditions a regeneration of the HPLC column and a cleaning of the injection system are recommended. Pre-column exchange is recommended once a week to avoid a contamination of the HPLC column which could lead to a loss in column life time (see figure A 1). A.1. Regeneration of the column Regeneration of the HPLC-column should be done according to the manufacturer's instructions. Note: There are newer column types that have become available since the completion of the CORESTA studies for the development of this method that may not require regeneration (e.g. Varian MetaCarb 67C) 2 A.2. Cleaning of the injection system The autosampler is disconnected and the injection system is flushed with distilled water at a flow rate of 1,5 ml/min followed by injection of 30 µl of distilled water (3 times), 50 µl 6M HNO 3 (3 times) and 70 µl distilled water (3 times) A.3. Lifetime of columns Examples of lifetime and number of samples for HPLC-Sugarpak columns used for routine analysis are documented in the following table Column Number of samples Runtime (hours) Period of use T 61571 A 28 2243 1226 07.01.97 31.10.97 T 61292 A 14 2304 1250 07.01.97 31.10.97 T 62991 A 15 2979 1484 10.02.97 23.04.98 T 71201 A 14 200 (complaint) 99 31.10.97 03.12.97 T 63461 A 04 3905 2108 05.06.97 18.12.98 T 72651 A 30 373 (complaint) 211 31.08.98 30. 11.98 2 MetaCarb 67C is a trade name of a product supplied by Varian. This information is given for the convenience of users of this Recommended Method and does not constitute an endorsement by CORESTA of this product. CRM No. 61 July 2015 Page 12/13

Figure A.1 Example of column regeneration Figure A.2 Example of injector cleaning and precolumn exchange CRM No. 61 July 2015 Page 13/13