MRI Information. MRI Safe The following AMS product does not contain metallic components and therefore is considered MRI Safe.

Similar documents
Magnetic Resonance Imaging (MRI) Safety for Boston Scientific Products. 1. WALLSTENT Iliac Endoprosthesis with Unistep Plus Delivery System

Replacement Heart Valve Product Description (Stented Tissue) Models Reference

12 pericardial bioprostheses. 7300TFX Carpentier-Edwards bioprosthetic valved conduit

RePneu (Lung Volume Reduction) Coil System Instructions For Use

Magnetic Resonance Imaging at 7T in Glasgow. A unique opportunity!

Testing Methods and Standards for Magnetic Resonance (MR) Safety and Compatibility of Medical Devices - Update

Comfort your patient deserves. Strength you demand.

MRI Safety. How can we ever forget?? July Missile Effect. Have we lost sight of our MR Safety responsibility?

Chapter 2. Magnetic Resonance Safety. Andrew Simmons and Kristina Hakansson. Abstract. 1. Legislation, Guidance and Best Practice

RePneuTM (Lung Volume Reduction) Coil System

Last Name First Name Middle Initial Previous Last Name(s)

YUKON DES. PEARL surface. Drug Eluting Stent System. Coronary Stent System for individual drug coating application. Stent coating machine

Magnetic Resonance Safety Update 2002: Implants and Devices

ADDIS ABABA UNIVERSITY CENTER OF BIOMEDICAL ENGINEERING

New PET/CT from Siemens helps more patients benefit from premium technologies

New Hope for Thalassemia Patients

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Eddy current testing of welds by complex-plane analysis

GENESIS Edition Transforming CT

Repliform. Tissue Regeneration Matrix. Instructions for Use. Distributed by:

GENESIS Edition. Transforming CT

Approval of subjects for measurements at ultra-high-field MRI

Physicists Quality Control for MR Equipment

MRI in Clinical Practice

Magnetic Force Microscopy: nanoscale magnetic imaging and lithography

Guide for Cleaning, Sterilization and Storage of Introducers for Caldera Medical Implants

Delivery uncertainties and their consequences

R/F. Experiences Using SONIALVISION safire and the Utility of Tomosynthesis. 1. Introduction. 2. Basics of Tomosynthesis.

MIIG INJECTABLE Graft The following languages are included in this packet:

MAGNETIC RESONANCE IMAGING OF IN VIVO FLOW PHENOMENA

Vibration effects in healthcare facilities

Saudi FDA Drug Approval Process. Dr. Mohammed A. Alquwaizani Consultant- Chief of the scientific office Saudi Food and Drug Authority

Implants for surgery Active implantable medical devices. Part 3: Implantable neurostimulators

Urology EHR Specialty Content

MRI Systems Market to 2018

Centricity Practice Solution. Practice Management CBT Role-Based Course Guide

Detecting Peripheral Nerves in the Elbow using Three-Dimensional Diffusion-Weighted PSIF Sequences: a Feasibility Pilot Study

Evaluation of the Susceptibility Artifacts and Tissue Injury Caused by Implanted Microchips in Dogs on 1.5 T Magnetic Resonance Imaging

Introduction to the SmPC guideline

SCIENCE. VALUE. INNOVATION.

ALLODERM SELECT ALLODERM SELECT RESTORE

Pre-clinical and postmortem diffusion MRI

Protect the Neck. Lieven Maene, MD. Marc Bosiers Koen Deloose Joren Callaert. Patrick Peeters Jürgen Verbist. Lieven Maene Roel Beelen.

Simple, intuitive and accessible MRI solution for preclinical research. M-Series Compact MRI Systems

7T MRI research in neurology: initial results and future research applications

MR Project Implementation Guide

Freshman/Sophomore Junior Senior

CRANIOS REINFORCED BONE VOID FILLER

NORIAN DRILLABLE TECHNICAL MONOGRAPH. Fiber reinforced calcium phosphate phate bone void filler

Module 8: Composite Testing Lecture 36: Quality Assessment and Physical Properties. Introduction. The Lecture Contains

Management of Clinically Significant Device Attributes not Contained in the GUDID: Augmented Unique Device Identifier Data AUDI

TRELLIS COLLAGEN RIBBON

Award Number: W81XWH TITLE: Magnetic Resonance Characterization of Axonal Response to Spinal Cord Injury

Detection of Implants and Other Objects Using a Ferromagnetic Detection System: Implications for Patient Screening Before MRI

SUBJECT: INSTITUTIONAL REVIEW BOARD (IRB) - HUMANITARIAN USE DEVICES

Recharge your MR experience.

MEDICAL PHYSICS (MED PHYS)

Smouldering myeloma. Myeloma Infosheet Series. Other related conditions. Infoline:

MEDICAL ELECTRONICS. Subject Title : Medical Electronics Subject Code : EC Hours Per Week : 04 Hours Per Semester : 64 TOPIC ANALYSIS

Tissue Magnetic Susceptibility Matched Pyrolytic Graphite Foam for Improved MRI. Gary Chiaray Lee

Ingenia MR-RT. MR Systems. The comprehensive MR-sim solution to fit your planning

S.M.A.R.T. Our inspiration came right from the source. Feeling is believing. S.M.A.R.T. Flex Vascular Stent System. LinkedIn page

DRAFT MEDICAL DEVICE GUIDANCE DOCUMENT

For special applications, we can also provide flexible and stiff nitinol guidewires with a longer and extra soft angled flexible safety tip.

Tom Taormina, K5RC Amateur Radio Emergency Coordinator Storey County NV

Bonded Neo Magnetization Guide

Clinical Translation of Tumor Acidosis Measurements with AcidoCEST MRI

Platelet Concentrate in Total Knees BIOLOGICS. This brochure is for International use only. It is not for distribution in the United States.

IT S A GLOBAL LEADER. IT S PROVEN.

Treatment planning for scanned proton beams and IMPT

The Role and Activities of ICNIRP and ICNIRP Exposure Limits and Guidelines

CoAxial Spray Kit And Applicator Tips. Simplifying the Application of Platelet and Plasma Concentrate

Recommended Agent First alternative for β-lactam allergy Alternative Agents (in order of preference) document β-lactam allergy for SCIP)

Post Market Surveillance (including PMCF): common non compliances

RapidPort EZ Port Applier DIRECTIONS FOR USE (DFU)

Radiography Curriculum Analysis

Connecting Cardiac Device Data and the EHR

MEDICAL DEVICES : Guidance document

MEDICAL DEVICES: TECHNOLOGIES AND GLOBAL MARKETS

Progress in X-Ray & MR

ClinScan. think forward. Small Animal MRI Solution for Molecular Imaging and Translational Research. Preclinical MRI

Optimize efficiency with a universal system.

18.0 INSTITUTIONAL BIOSAFETY COMMITTEE

NANOCRYSTALLINE VITROPERM EMC COMPONENTS ADVANCED MATERIALS THE KEY TO PROGRESS

Magnetic Resonance Imaging 23 (2005)

GE Healthcare. Vivid S6. Cardiovascular ultrasound system

12. Global Requirements for Medical Applications of Chitin and its Derivatives

Biomedical Engineering an Introduction

Performance estimation of a remote field eddy current method for the inspection of water distribution pipes

ISO INTERNATIONAL STANDARD. Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process

Borehole NMR: Different Problems Different Solutions

Fluoroscopy units come in many different physical configurations but all consist of the main components shown in this slide.

LOGIQ S8 with XDclear Simply Amazing

Transcription:

August 2015 MRI Information Several Magnetic Resonance Imaging (MRI) studies have concluded that the AMS products listed below will not produce additional risks to patients in association with MRI procedures under the conditions used for testing. In these investigations, AMS products underwent evaluations for magnetic field interactions at 1.5 and/or 3.0 Tesla. No unsafe magnetic field interactions were identified by this research. 1 MRI Safe The following AMS product does not contain metallic components and therefore is considered MRI Safe. AdVance Male Sling System MRI Conditional ( MR Conditional ) Some AMS products are MRI Conditional up to 3.0 Tesla. These products include: AMS 800 Urinary Control System Inflatable Penile Prostheses: AMS 700 CX, CXM, CXR, Ultrex, Ultrex Plus, AMS 700 LGX AMS Ambicor Inflatable Penile Prostheses Spectra Penile Prostheses MR parameters for these products are provided in the individual device s instructions for use as well as on pages 3-6 of this document. Additional MRI testing was conducted on some AMS devices at 1.5 and 3.0 Tesla to evaluate the impact of MR imaging on the devices that contain metallic components. Testing conducted at 1.5 Tesla concluded that torque, deflection angle, and heating/temperature change results for the following products were found acceptable: AMS Artificial Urinary Sphincters 791 and 792 InVance Male Incontinence Sling System Malleables: Dynaflex / Hydroflex Malleables: AMS 600 / 600M / 650 / Dura II ; and Spectra UroLume Endoprosthetic Stent AMS Mainstay Urologic Soft Tissue Anchor 1. Data on File

Testing conducted at 3.0 Tesla concluded that torque and deflection angle results for the following products were found acceptable: AMS Artificial Urinary Sphincters 791 and 792 InVance Male Incontinence Sling System Malleables: Dynaflex / Hydroflex Malleables: AMS 600 / 600M / 650 / Dura II UroLume Endoprosthetic Stent AMS Mainstay Urologic Soft Tissue Anchor AMS Men's Health Company Contact: Rich Broda, AMS Men's Health Patient Liaison, at 800-328-3881 extension 6261, or 952-930-6261, or Email at Patient.Liaison@bsci.com, Monday-Friday 7:00am until 4:00pm Central Time.

AMS 700 and AMS Ambicor Penile Prostheses Additional data Magnetic Resonance Imaging (MRI) Important Safety Information Non-clinical testing has demonstrated the penile prostheses AMS 700 / AMS Ambicor product line is MR Conditional. The device can be scanned safely under the following conditions: Spatial Gradient Field 450 Gauss/cm or less 720 Gauss/cm or less Maximum whole body averaged Specific Absorption Rate (SAR) 1.5 W/kg for 15 minutes of 2.9 W/kg for 15 minutes of MRI-Related Heating Non-clinical testing has demonstrated the penile prostheses AMS 700 / AMS Ambicor product line produced the temperature rises during MRI performed for 15 minutes of scanning in the respective MR systems which would not pose a hazard to the human subject. Highest Temperature Change +0.4 C +1.9 C Artifact Information Non-clinical testing has demonstrated that the penile prostheses AMS 700 / AMS Ambicor product line may compromise the MR image quality if the area of interest is relatively close to the position of the implant. The maximum image artifact produced by a MR gradient echo pulse sequence was a moderate localized signal void in size and shape of the implant. Optimization of MR imaging parameters to compensate for the presence of the device may be necessary. Pulse Sequence T1-SE T1-SE GRE GRE Signal Void Size 6,244 mm 2 1,589 mm 2 10,295 mrn 2 2,779 mm 2 Plane Orientation Parallel Perpendicular Parallel Perpendicular

AMS 800 Urinary Control System Additional data Magnetic Resonance Imaging (MRI) Important Safety Information Non-clinical testing has demonstrated the AMS 800 Urinary Control System product line is MR Conditional. The device can be scanned safely under the following conditions: Spatial Gradient Field 450 Gauss/cm or less 720 Gauss/cm or less Maximum whole body averaged Specific Absorption Rate (SAR) 1.5 W/kg for 15 minutes of 2.9 W/kg for 15 minutes of MRI-Related Heating Non-clinical testing has demonstrated the AMS 800 Urinary Control System product line produced the temperature rises during MRI performed for 15 minutes of scanning in the respective MR systems which would not pose a hazard to the human subject. Highest Temperature Change + 0.4 C + 2.0 C Artifact Information Non-clinical testing has demonstrated that the AMS 800 Urinary Control System product line may compromise the MR image quality if the area of interest is relatively close to the position of the implant. The maximum image artifact produced by a MR gradient echo pulse sequence was a moderate localized signal void in size and shape of the implant. Optimization of MR imaging parameters to compensate for the presence of the device may be necessary.

Pulse Sequence T1-SE T1-SE GRE GRE Signal Void Size 5,800 mm 2 1,956 mm 2 6,096 mrn 2 2,650 mm 2 Plane Orientation Parallel Perpendicular Parallel Perpendicular Spectra Concealable Penile Prosthesis Additional data Magnetic Resonance Imaging (MRI) Important Safety Information Non-clinical testing has demonstrated the Spectra Concealable Penile Prosthesis product line is MR Conditional. The device can be scanned safely under the following conditions: Static Magnetic Field 3.0 Tesla a Spatial Gradient Field Maximum whole body averaged Specific Absorption Rate (SAR) 720 Gauss/cm or less 2.9 W/kg for 15 minutes of (a) 3.0T 128MHz, General Electric Healthcare, Excite software version G3.0-052B MRI-Related Heating Non-clinical testing has demonstrated the Spectra Concealable Penile Prosthesis ABS product line produced the temperature rises during MRI performed for 15 minutes of scanning in the respective MR systems which would not pose a hazard to the human subject. Static Magnetic Field 3.0 Tesla a Highest Temperature Change +1.6 C (a) 3.0T 128MHz, General Electric Healthcare, Excite software version G3.0-052B Artifact Information Non-clinical testing has demonstrated that the Spectra Concealable Penile Prosthesis product line may compromise the MR image quality if the area of interest is relatively close to the position of the implant. The maximum image artifact produced by a MR gradient echo pulse sequence was a moderate localized signal void in size and shape of the implant. Optimization of MR imaging parameters to compensate for the presence of the device may be necessary. Pulse Sequence T1-SE T1-SE GRE GRE

Signal Void Size 7,193 mm 2 1,553 mm 2 1,160 mrn 2 7,030 mm 2 Plane Orientation Parallel Perpendicular Parallel Perpendicular This letter contains important safety information on the use of magnetic resonance imaging with AMS products. For additional product information on indications for use, contraindications, warnings, precautions, and adverse events, please refer to the product s instructions for use. 2015 by Boston Scientific Corporation or its affiliates. All rights reserved. All trademarks are the property of their respective owners. US/CORP-00531(4)/August 2015/U.S. Use Only