SUSTAINABILITY An Energy & Emissions Case Study

Similar documents
Energy Reduction Strategy Through 2020

Benefits of Green Buildings. Government Finance Officers Association of Texas April 2014

ENERGY AND WATER CONSERVATION AND DEMAND MANAGEMENT PLAN

Energy and Climate. Energy and Climate. Summary of Activities and Performance

2.2. Energy and Emissions

SYRACUSE UNIVERSITY ENERGY CONSERVATION

Centre for Addiction and Mental Health Queen Street Campus Energy Conservation and Demand Management Plan

Deep Energy Savings in Existing Buildings

Building Careers in Sustainable Facilities Design and Management

Texas Tech University Energy Savings Program October 2010 Update

Presented by Bruce Rich, P.E., CCM, LEED AP Parsons Brinckerhoff

Energy Retrofit Loan Program

Energy Efficiency Planning. June 30, 2009

Air Source Heat Pumps in the Commercial Market. Thursday, February 5, :00-10:30 a.m.

Energy Conservation at the University of Pittsburgh - FY2014 and Beyond

KEY FACILITIES METRICS SURVEY

Anchorage Alaska Solar Tour: Saturday, June 17th, 2017 Tour Starts At 10am

A METHODOLOGY FOR REDUCING BUILDING ENERGY CONSUMPTION

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 9/30/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

GREEN U.S. EMBASSIES. Low Carbon Cities April 22, 2014

Research Analysis: Building Envelope and LEED Credits Introduction

Status of the New ECE Building at the University of Illinois

LEED. Leadership in Energy and Environmental Design

Conservation and Demand Management Plan

DCAS Energy Management. August 15, 2014 Ellen Ryan & Mike Dipple

SAMPLE ZNE PRESENTATION

future-proof energy with photovoltaic systems

White Paper ENVELOPE-FIRST APPROACH TO NET-ZERO ENERGY BUILDINGS

Mount Sinai Main Hospital Energy Conservation and Demand Management Plan

Penn State AE Senior Thesis 2009

Greenhouse Gas Emissions Inventory 2015

TULANE UNIVERSITY. Climate Action Planning: Work In Progress

South Carolina Society for Hospital Engineers

Energy Efficiency Solutions for Multifamily Housing. Clark Energy Group LLC

Partner for Change : Energy

Analysis 1. LEED Analysis of Laboratory Buildings. Penn State School of Forest Resources University Park, PA

GSK Cork. Global Energy Management System Implementation: Case Study. Ireland. Business Case for Energy Management. Case Study Snapshot

The Low Hanging Fruit Energy Efficient Lighting

Carbon Neutral 60% 70% 80% 90% Today

2. How can the University have an expansion of the Cogeneration Facility without an increase in the amount of coal used?

Midwest Healthcare Engineering Conference. ASHRAE Standard : Sustainability Defined for Healthcare

Emerging Zero Net Energy School Retrofit Case Study NEWCASTLE ELEMENTARY SCHOOL OVERVIEW. Planning and Design Approach

Renewable Energy Benefits from Biomass for a College Campus

GM Energy, Carbon, & Water Management. Al Hildreth, PE, CEM General Motors Company Energy Manager 16-May-2012 SPE Energy team

City Council Staff Report

ABOUT BOMBARDIER INC. AND BOMBARDIER AEROSPACE

GREEN AND ENERGY EFFICIENT BUILDINGS INTERNATIONAL BENCHMARK : THE THREE MODELS

ENERGY AUDIT. 123 Main Street Mississauga, Ontario. January 1, Report To: Mr. John Smith Smith Printing Company.

A Plan for a Sustainable Toronto Discovery District

Vanderbilt University Combined Heat and Power Plant. A history of sustainable progress

213 kbtu/ kbtu/ sq ft. sq ft 2008 / 2,814,009 MMBTU 2016 / 2,934,161 MMBTU / 438,242 MTCO2e 2016 / 284,934 MTCO2e 202

BUSINESS NEW CONSTRUCTION Energy Design Assistance Energy Efficient Buildings

District Energy Combined Heat and Power as a Resource

Thermal Energy Storage

A Building Commissioning Overview. Presented by: Goetting & Associates Commissioning

Fossil Fuels (Non-Renewable) Environmental Stewardship. Educational & Research Opportunities. Faculty, Staff, Students Recruitment & Retention

Texas Hospital. Central Plant Redesign. Central Utility Plant SECOND PLACE HEALTH CARE FACILITIES, EXISTING 2013 ASHRAE TECHNOLOGY AWARD CASE STUDIES

Sustainable Building Operations & Upgrades

Greenhouse Gas (GHG) Emissions Inventory Fiscal Year 2011

2016 LEED Equivalency Analysis for Stanford Campus

ICEBANK Ice Storage Systems

AEP Ohio. Combined Heat and Power (CHP) May 24 th, 2017 Steve Giles Vice President Alternative Energy Hull & Associates, Inc.

Clemson University's Central Energy Facility and Energy Systems Laboratory An Integration of Operations and Academics

LEED Application Guide for Multiple Buildings and On Campus Building Projects

Energy Savings at Military Installations: A Case Study

LEED Commissioning and Actual Energy Use. John Kokko, P.Eng. LEED A.P. Vice President Enermodal Engineering

University Health Network. Energy Management Plan 2014 to Energy & Environment. University Health Network

Conservation & Demand Management Plan

Construction Specifications Canada Conference May 23, BOMA BESt

One That is Already Built.

Tate Laboratory of Physics Building Analysis

Roadmap to Resilient, Ultra-Low Energy Buildings in the Pacific Northwest

ENVIRONMENTAL FOOTPRINT 2O16

A Climate Action Plan

The Cincinnati Insurance Companies ENVIRONMENTAL STEWARDSHIP 2017

ZERO GREENHOUSE GAS EMISSIONS

Stanford s Energy Story Present and Future

What s New at the Massachusetts Clean Energy Center

Green Building & Energy Efficiency

DLR Group is ranked #1 by ARCHITECT, the official publication of the American Institute of Architects, in its 2012 ARCHITECT 50 ranking of U.S.

UC Irvine Energy Efficiency Energy Storage Energy Optimization. Matt Gudorf CEM, LEED AP Assistant Director Energy, Engineering, and Inspection

KANE COUNTY ENERGY AND ENVIRONMENTAL COMMITTEE THURSDAY, SEPTEMBER 11, County Board Room Agenda 9:00 AM

WFM. Big Box Retail CCHP

LEED 2009 for New Construction and Major Renovations

Profit, Planet and People: Achieving the Triple Bottom Line through Energy Efficiency

Building a better tomorrow, today

PHOTOVOLTAIC ROOFING SYSTEMS

Advantages of Financing Continuous Commissioning As An Energy Conservation Retrofit Measure

ROCKY MOUNTAIN LAND USE INSTITUTE DENVER, COLORADO MARCH 4, :00-10:15 AM

New Jersey Board of Public Utilities Clean Energy Incentive Program

Using a Whole Building Approach to Energy Efficiency

USGBC & LEED. A Summary of the LEED Development as a primer for LEED ND

Pepco Holdings, Inc. (PHI) C&I Energy Savings Program Commissioning and O&M Incentives

2 Kinds of Cool by Philip H. DeBels P.E., CSBA, LEED AP Brian Berard LEED AP Clara Simon LEED AP Tara L. Frentrop P.E., LEED AP

SIMULATION MODEL IN TRNSYS OF A SOLAR HOUSE FROM BRAŞOV, ROMANIA

Sustainable Maintenance Best Practice: Energy Efficiency in the Carbon Free World. Michel Abi Saab. Team Leader, Energy Efficiency LEED AP, CEM, CMVP

CHILLED WATER PRODUCTION SUB-ELEMENT

Erik J. Kocher, AIA, LEED AP Pi Principal i

The Challenge. Daikin s Solution. Application: Residential. Location: Toronto, Canada FINANCIAL MOTIVATION THE. To build a better green home

2012 Green Homes Tour

Transcription:

SUSTAINABILITY An Energy & Emissions Case Study 1

Energy & Emissions Case Study WASHINGTON UNIVERSITY IN ST. LOUIS has a history of responsibly investing resources to increase the efficiency of our operations and decrease our impact on the environment. Much of this effort to date has been focused on reducing energy use across our campuses. We have seen great success. Since 1990, the Danforth Campus (the school s central campus) and the Medical School Campus have added almost 5 million square feet, nearly doubling in size, while holding energy use flat. Our Progress at a Glance Building Area (Sq. Ft.) 11,000,000 10,000,000 9,000,000 8,000,000 7,000,000 6,000,000 Building Area vs. Energy Use 3,500,000 3,000,000 2,500,000 2,000,000 1,500,000 1,000,000 500,000 Energy Use (MMBtu) Building Area vs. Energy Use: Even though Washington University s building area has nearly doubled in size, our energy use has held flat. While investments have primarily focused on energy use reduction, we have also seen success in shrinking carbon emissions. 5,000,000 Fiscal Year 0 Building Area Energy Use From 2010 to 2015, our carbon emissions decreased by 17,199 metric tons of CO 2 despite the construction of buildings that added more than 585,000 net square feet of new space for teaching, research, and patient care. As we turn to the future, we have an expanded focus on carbon reduction, while continuing efforts to decrease energy usage. Our goal is to reduce emissions by 51,300 metric tons of CO 2 over the next five years. 0.05 0.04 0.03 Emissions Per Square Foot Emissions Per Square Foot: University emissions per square foot have declined by 33 percent over the last 25 years. Washington University has achieved this success by making a set of ongoing investments in energy conservation and carbon reduction strategies. The investments are driven by the university s decision to invest capital in energy conservation projects that have a positive financial return. All of the techniques described here are good long-term business investments that are helping us reach our long-term sustainability goals. 0.02 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 Fiscal Year Cumulative Cost Savings $120,000,000 Emissions Per Square Foot $100,000,000 $80,000,000 $60,000,000 $40,000,000 Cumulative Cost Savings: The university s reduction in carbon emissions and energy use have resulted in significant cost savings. $20,000,000 0 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 Fiscal Year Annual Cost Avoidance Cumulative Cost Avoidance 2 1

How Have We Achieved Success Major Utility Improvements Much of our increased efficiency has come from a set of investments in major utility systems across our campuses. As a group, these improvements are the biggest factor in our success in energy and carbon reduction and have resulted in a positive financial return. Conversion to Natural Gas Building Metering Utilities on Campus Electric System The old electric distribution system was phased out, allowing retirement of aged cable and incorporation of a more reliable loop feed. Metering The utilities teams at the Medical Campus and the Danforth Campus recently completed a major multi-year, $5.9 million project to meter energy use in all buildings. Lighting Over the past 6 years, over 5 million square feet (and approximately 40,000 individual lamps) have been upgraded to high efficiency lights. Over a decade, both campuses switched from using coal boilers to using high efficiency dual fuel boilers, which utilize natural gas and fuel oil. Simultaneously, the university s central campus moved from a centralized main steam plant to 11 regional thermal plants to maximize distribution efficiency across campus by minimizing thermal loss. These changes resulted in more reliable steam production, a reduction in labor, less thermal distribution loss, and a decrease in CO 2 emissions. High Efficiency Boilers As part of the conversion from coal to natural gas, inefficient boilers from the 1930s 1940s were replaced with new high efficiency boilers for more efficient steam production. These new boilers have higher combustion efficiency due to the boiler design and more advanced control of the combustion air. Heat Recovery Chillers The university s two major campuses have completed a $5.9 million project to install energy meters in all buildings. The meters measure usage of electricity, natural gas, hot water for heating, and cold water for cooling. The project, consisting of 500 meters on the Danforth Campus and 230 meters at the School of Medicine, is complete and in its first year of operation. We have already discovered and are working to correct operational deficiencies in several buildings that were previously unknown. On both campuses, these systems enable us to: Quickly flag and correct inefficiencies. Establish energy-use benchmarks based on space type and identify outlier buildings to target for energy conservation. Support incentive programs to drive user engagement in energy conservation. Due to the size and complexity of institutional buildings, there are many university buildings that require simultaneous cooling and heating. To efficiently meet this need, the university has replaced traditional chillers with heat recovery chillers that capture what would otherwise be wasted heat from the cooling process to provide heating where it is needed. The heat recovery chillers are significantly more efficient and have allowed the university to turn off gas boilers from May to October that would otherwise have operated year-round. Lighting Retrofits The university is engaged in ongoing retrofits of interior and exterior campus lighting. To date, these efforts have included the conversion of four campus parking garages and 400 exterior site lights to LEDs and over 5 million square feet of interior space upgraded to efficient T8 lamps with electronic ballasts. We project that these lighting upgrades are saving us $709,000 annually, as well as reducing our carbon emissions by 8,800 metric tons per year. Our lighting projects have underscored the importance of doing full life-cycle cost analyses. Certain projects were not justifiable on energy savings alone; however, when we factored in labor and material savings from using lamps with significantly longer life spans, the projects were clear winners. Example: In a business school building, the meters detected an unusually high amount of chilled water for cooling. An investigation discovered that a software override was causing the system to constantly read the outside air temperature as greater than 90 degrees, regardless of the actual temperature. This caused the system to cool all incoming outside air, even if it was below 55 degrees and did not require cooling. After the software override was released, there was an immediate reduction of approximately 100 tons in cooling energy. This allowed one of the chillers on the loop to be turned off entirely resulting in a savings of $28,000 a year in energy costs. Upgraded Electric System Beginning in the 1990s, the university began a comprehensive upgrade of the electric systems on campus. Upgrades included a new electrical substation dedicated to the portion of campus that houses undergraduate dorms, and a new main substation with the capability to meet future campus growth and improve electric reliability. We also replaced our radial electric distribution system with a loop distribution system, allowing the retirement of aged cable and creating a more reliable system. Other Major Improvements A decentralized heating plant converted to low pressure steam. New HVAC systems and controls on the Medical Campus to help meet energy conservation goals. Boilers High efficiency boilers (90 percent efficient) replaced low efficiency boilers (50 percent efficient) on both the Danforth Campus and the Medical Campus. Heat Recovery Chillers Natural Gas More Efficient Between 1995 and 2002 both campuses switched from coal to natural gas. Both campuses installed heat recovery chillers that capture waste heat for use and allow some buildings to stop using natural gas during the summer. 2 3

Very Efficient New Buildings and Major Renovations Energy Conservation Investments Washington University has adopted two key green building standards: a LEED Silver minimum and the requirement that projects perform 30 percent better than the ASHRAE 90.1-2010 energy efficiency standard, a leading national energy standard for buildings. Since 2010, the university has built 14 new buildings totaling 1.5 million square feet. 95 percent of the total square feet built has exceeded our LEED Silver building minimum 22 percent of the space is certified LEED Platinum 74 percent of the space is LEED Gold Operating costs of new buildings are at least 30 percent lower than those of a standard building. The Living Learning Center which is part of the university s ecological field station, Tyson Research Center is one of the first buildings in the world to receive Living Building Challenge certification. This is the most stringent green building rating system in the world, requiring net-zero energy and net-zero water operations. Example: Hillman Hall (Brown School) LEED Platinum Designed to be 41 percent more efficient than a conventional building 50 kw rooftop solar array A roof deck with planting beds Site design featuring a large rain garden and dynamic outdoor spaces that are fully integrated with bike and pedestrian infrastructure to reduce parking demand For the past 20 years, university leadership has had a policy of providing up-front capital support for energy conservation projects with positive long-term financial returns. In 2013, we committed to invest $30 million in energy conservation projects prior to 2020. By mid-year 2015, we had completed $6.5 million of projects with an additional $3.9 million of projects in-progress. This long-range view has enabled the investment necessary to halve energy use per square foot over the last 25 years. Departments have historically looked at payback period or net present value (expected income minus the cost of the project) to determine which projects to fund. This approach has allowed us to identify projects with strong financial and environmental returns, many of which are described here. Until recently, however, the university did not have a standardized financial model used across departments, resulting in some inconsistency in application and some missed opportunities. In 2014, Executive Vice Chancellor Hank Webber tasked a cross-campus energy and emissions working group consisting of key staff from the Facilities teams, Financial Planning, and the Office of Sustainability with standardizing and publishing the university s financial modeling guidelines for projects that impact utility costs, including energy, water, and storm water. The goal was the creation of a standard to be used by staff and consultants to ensure that all potential projects would be modeled using a consistent set of assumptions based on the best available data. The final document outlines standardized assumptions for: Utility costs Escalators Life-cycle cost analyses Payback periods Net present value Carbon saved per dollar spent Financial analyses both with and without the social cost of carbon (Those interested in obtaining a copy of these guidelines can go to tinyurl.com/financialmodelingguidelines.) The updated guidelines give university leadership confidence that all potential projects have been evaluated using the same criteria. Once applied to a suite of potential projects, the updated guidelines identified a greater number of projects with strong financial return and significant carbon reduction than were previously known, allowing the university to adopt a more aggressive 2020 greenhouse gas reduction goal. Staff Training and Engagement Staff members knowledge and leadership are crucial in the university s mission to reduce its environmental impact. The university has energy engineer roles at both campuses, 12 staff members are LEED Accredited Professionals, 95 staff members have received Facility Management Professional accreditation, and 43 staff members have received Sustainability Facility Professional accreditation. The university s energy and emissions working group meets at least bi-monthly. The working group oversees a broad range of energy conservation measures including utility system upgrades, lighting retrofits, retro-commissioning, and behavior change. The group is also tasked with proposing policy changes and the development of standards, such as the financial modeling guidelines. 4 5

Next Steps Updated 2020 Goal The university has set an ambitious goal to reduce greenhouse gas emissions to 1990 levels by 2020, representing a reduction of 51,300 metric tons of CO 2. In 2010, the university set a goal to reduce greenhouse gas emissions to 1990 levels by 2020 without purchasing carbon offsets. Five years into this effort, we have updated this goal to make it even more ambitious. Our new goal is to reduce greenhouse gas emissions to 1990 levels by 2020 including all campus growth, which requires reducing emissions by 51,300 metric tons of CO 2 by 2020. This new goal nearly doubles the reduction required by the previous goal. As ofjuly 2015, we are 14 percent of the way to meeting our new goal. We continue to identify and invest in projects that provide a positive financial return and help us further reduce energy use and emissions. The university has been very successful in its campaign to reduce energy use. While we will continue to target further reductions, we recognize that there is a need to give equal attention in the future to reducing carbon emissions. Our experiences to date have demonstrated that projects that result in energy and cost savings do not always reduce carbon emissions because there are different levels of emissions from different energy sources. Emissions reduction must be an explicit focus of decision-making to ensure projects contribute to our greenhouse gas reduction goal. 51,300 metric tons 16 17 18 51,300 19 20 metric tons of CO 2 over the next five years. A 51,300 MT reduction is equivalent to taking 10,800 cars off the road. 6 7 The Lofts of Washington University is an offcampus student housing complex that has been designated LEED Platinum. The four buildings 46 percent more efficient than conventional buildings get 10 percent of their electricity and 25 percent of their hot water from rooftop solar panels. The Lofts also features a water-harvesting cistern for irrigation, south facing sun shades, and a rain garden.

Strategies to Meet 2020 Carbon Reduction Goal In order to meet its 2020 reduction goal, the university will utilize three major strategies. Continued Investment in Financially Sound Projects We will continue to implement the projects outlined in the case study and will work to identify projects that provide a positive financial return while advancing our goals of energy and emissions reduction. As technology evolves and staff expertise expands, the university will identify additional financially sound energy reduction projects. $3 Million Retro-Commissioning Study Program Using metering data, we are improving the efficiency of building systems. Now that all university buildings have been metered, our facilities teams are looking closely at the biggest users on both campuses to identify ways to reduce their energy usage and emissions. The Danforth and Medical campuses recently initiated a retrocommissioning program aimed at reducing our energy use, reducing our greenhouse gas emissions, and improving occupant comfort. Retro-commissioning involves studying and adjusting building systems, including equipment and control systems, to ensure they are performing optimally. In order to focus our efforts, we used building-level metering data to identify the buildings with the highest energy usage (both total energy use and energy use per square foot). The metering data revealed that 35 of our 100-plus buildings use more than 70 percent of the energy on the Danforth Campus. Eight buildings were selected for the pilot phase of in-depth retro-commissioning studies. The studies are taking place in 2015, with implementation of the recommendations to follow in 2015 and 2016. Example: Pilot studies of a few buildings are already producing encouraging results. The initial study of a biomedical engineering building resulted in recommendations that are projected to reduce the building s greenhouse gas emissions by over 20 percent, with predicted cost savings that would exceed the university s investment in less than one year. Continued Investment in Renewable Energy New building designs anticipate future integration of renewable energy. Washington University s greenhouse gas reduction strategies have traditionally focused on energy conservation. With the rise in utility rates and the concurrent significant reductions in the cost of renewable energy, the university is now planning for a near-future in which on-site and off-site renewable energy will be cost-competitive with grid electricity. This includes designing buildings and building systems for easy future integration of on-site generation. In addition, the university is studying a range of innovative energy system concepts based largely on renewable energy for the future build-out of sections of our Danforth campus. Example: In 2014 and 2015, Washington University added 548 kilowatts of solar photovoltaics to university-owned property, including the Danforth Campus, Medical Campus, Tyson and other satellite locations. The new arrays represent our first major investment in renewable energy. The investment will pay off by producing enough emission-free energy to power the electrical usage of 65 average U.S. homes and save the university more than $100,000 over the first 10 years alone. The installations include roof-mounted systems, ground-mounted arrays, and a solar carport that engineering students plan to link to an electric vehicle charging station. The university also installed solar thermal panels for heating domestic hot water on a LEED Platinum off-campus student housing project and the Brown School s Hillman Hall. 548 kilowatts of solar photovoltaics added to university-owned property 20% reduction in a building s greenhouse gas emissions 8 9