ST 19 Aluminium Manually Controlled Electric Model

Similar documents
Cutlass Fasteners, Inc. 83 Vermont Ave., Unit 6, Warwick, RI Tel: (401) Fax: (401) cutlass-studwelding.com

INSTRUCTIONS FOR THE ASSEMBLY AND INSTALLATION OF THE VORTOX LIQUID SAMPLER

MALTE Outdoor. the compact and versatile posterior-walker. Instructions for use

MODELS PH PH PH

TECHNICAL DATA SHEET DS 060

Z5033 E3 Ball joint adapter Mounting instructions

WE01A GMA (MIG) Plug Weld

Instructions for Continued Airworthiness Talon LC Keeperless Cargo Hook Kit For the AS350 Series. System Part Number STC SR00886SE

Operating Instructions

FILTRATION & UV SYSTEM

Bateau, Crucible and Timpani Vessels Installation and User Guide

Protective Capony RTC-16

MEDICAL TRADING knows the meaning of sterilization very well: it can be

Thank you for purchasing our product. *Please read these instructions and follow them step by step.

TAKING YOU TO NEW HEIGHTS IN SAFETY... kwikstage

Instruction Manual HK285. Note: The Owner/Operator must read carefully and understand all the information presented here before operation.

FERTILIZER IRRIGATION EQUIPMENT LTD. SERIES 6000 APPLICATIONS

INSTALLATION INSTRUCTIONS

300828TWP INSTALLATION INSTRUCTIONS MODEL SUBMERSIBLE SUMP PUMP

OPERATION MANUAL. Beam Clamp with Shackle

Model BF 720 Incubators Avantgarde.Line with forced convection

BESTMOVE STANDING TRANSFER AID

Model FD 115 Drying and heating chambers Avantgarde.Line with forced convection

ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200

Manual Rotary Heat Sealers. Type: F108TX. List of content : Introduction 2. General description 3. Application 4. Safety precautions 5

BOILER INSTALLATION INSTRUCTIONS FOR RU 1S / BRU 1 RU 2S / BRU 2 RU 3S

FW66 FORESTRY WINCH FW66. Owner s Manual 19/02/2016

Sby SR Instruments, Inc.

1600 Currency counting machines

BESTMOVE STANDING TRANSFER AID

Model # 922-S4. 12/18/2013 Page 1 of 8

BoSS Climalite Camera and lighting tower

Installation plan. Tumble dryer. PT 8807 EL (Electrically heated) en - US Mat. NR / 02

NAVSEA STANDARD ITEM. 2.1 S9086-RJ-STM-010/CH-504, Pressure, Temperature and Other Mechanical and Electromechanical Measuring Instruments

Shackles. Applications. Range. Design. CAD drawings. Finish

Z5028 E3/Ci80 Horizontal bracket Mounting instructions

INSTRUCTION MANUAL FOR USE AND MAINTENANCE

Model # 158-P4. 12/12/2013 Page 1 of 11

2 ADAPTER MOUNTING & APPLICATION

Model # 800SM-PS3. 8/3/2016 Page 1 of 8

Direct contact and metal-to-metal seating make the T-pattern globe stop valve ideal for most shut-off applications.

WE11S GMA (MIG) Fillet Weld

BESTMOVE STANDING TRANSFER AID

Z5043 MAX Horizontal bracket Mounting instructions

OVERSHOT GATE TECHNICAL DATA SHEET

Instruction Manual HT 24 BM-D2400 Homogenizer

PMA 31-G. English. Printed: Doc-Nr: PUB / / 000 / 00

Air flue duct for use with ecotec boilers

CALIBRATION TABLE OF CONTENTS. 9.1 Calibration

1675 Locust Street Red Bud, IL Phone: Fax: WARRANTY & TERMS

801-MORD Mordred FIXING: Ground. ORDER No: CUSTOMER: Complied by Date AB 30/06/15 ISSUE ECN DATE SIGN /07/15 AB

Preparation and Installation of the FA, FAV, and FAS Type Rupture Discs in Forward Acting Insert, Full Bolted, and Union Type Holders

Model # 358H-PR. 4/8/2011 Page 1 of 12

Thank you for purchasing the SC-CONVERSION System 500/600 Conversion Kit. This Kit is available in two different versions:

Operator s Manual for Morse CE-Marked Hydra-Lift Drum Rollers 456-CE Series

PS-31 (SUS304, 300 mm) PS-31 (SUS304, 1,000 mm)

Modular Coldroom Installation Manual

USER MANUAL BR LED Headlight Rev /05/2016

MOUNTING SYSTEM FOR PITCHED ROOF WITH TILES. mounting system for pitched roof with tiles for solar panels in landscape setup. Rev

Model # 238HS-P8. 4/27/2011 Page 1 of 11

Read Only Copy Not For Distribution. Chapter 17. Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.2 QUANTITY OF WATER REQUIRED

Instruction Manual ODY-1765

SECTION SLUICE GATES

INTERNATIONAL STANDARD

Model # 358-R48. 7/7/2011 Page 1 of 11

Model # 338S-OP. 9/30/2011 Page 1 of 13

Railway Freight Car Inspection and Safety Rules

The Filterautomat. Our Filter Systems Protect. The New Definition of Purity for Your Medium. flow rate 5 m 3 /h to 4,000 m 3 /h. filter fineness 5 µm

AP5K-C Precision AC Double-Pulse Spot Welding Machine User s Manual Shenzhen Will-Best Electronics Co., Ltd

Z5010 (Version 2) TV spigot with fixing plate Mounting instructions

Installation plan. Washer-extractor PW 6107 EL. en - GB M.-Nr / 01

INSTALLATION GUIDE Sika SolarMount 1 Exposition East West

Adjustable Fused Power Supply

Operation Manual. 120V Lithium Ion Cordless Chainsaw MODEL #

Model BF 260 Incubators Avantgarde.Line with forced convection

HIGH SEAL ULF Live Loaded Packing System

Regulating valves REG 6-65, REG-SS 15-40

All Prospective Bidders. SUBJECT: Addendum #2. DATE: April 8, Huntley High School Athletic Field Improvements Bid Release #2

ATT-42/95 SAMPLING, Asphalt

Global Water Instrumentation, Inc.

Owners Manual Models: 200-RODI4-XXX. US Water Systems 4 Stage RO/DI System Installation and Maintenance Manual.

INSTALLATION INSTRUCTIONS FOR ELECTRICAL CONTRACTORS

Using petrol-driven chainsaws

NVD-40 NEAR VERTICAL DRUM LIFTER INSTRUCTION MANUAL

YOUR STEP-BY-STEP GUIDE TO THE PERFECT INSTALLATION. Non-Lit Magnifying Mirrors

MODEL SJ10. Installation Manual. SumpJet TM - Water Powered Backup System C IMPORTANT: MODEL SERIAL

PART MATERIAL REMARK Metal Case with Pig-tail. Brass (Metal Case) Copper (Pig-tail) Star Contact Copper Silver Plated

PRICES: DESIGN: TAXES:

Leap Side Panel (S43E)

FIXTURE CARRIERS TABLE OF CONTENTS S-WD-FC

BUILD A SHOWER CUBICLE

Liner Replacement Instructions:

FITOCLIMA WALK-IN STABILITY

SAFETECH 3.2K ST v1.0. User s manual. Opale-Parachutes.com. Please read this manual before first use.

Operate Manual. DA-1600i Stud Welding Machine. DA-2000i Stud Welding Machine. DA-2500i Stud Welding Machine

Model # BARK-358-RDP

BRITESTREAM LED NICHE LIGHT

Installation recommendations. Washer-extractor PW 6080 EL AV/LP. en - GB Mat. no / 01

Drag Chain Conveyor Installation and Operation Manual

Installation, Operation & Maintenance Manual

Transcription:

ST 19 Aluminium Manually Controlled Electric Model Operators Manual Issue 5 For correct operation of this autoclave it is essential that the chamber be filled with water up to the height of the studs before every use. DIXONS SURGICAL INSTRUMENTS LTD, 1 ROMAN COURT HURRICANE WAY, WICKFORD BUSINESS PARK WICKFORD, ESSEX, SS11 8YB, UK TEL: +44 (0)1268 764614 - FAX: +44 (0)1268 764615 EMAIL: info@dixons-uk.com - WEB: http://www.dixons-uk.com Warning - All external body and lid surfaces are hot during and immediately after sterilisation. Lift or move the autoclave by the top handle only.

7. Illustration A Draw-off Cock F Collared Wing Nut (2) B Aircock G Plain Wing Nut (6) C Pressure Gauge H Drop Bolt (8) D Safety Valve J Switch Box E Thermometer

Notes Foreword Before using this Dixons Portable Autoclave please read this booklet carefully. Please ensure that all persons likely to use this product are correctly trained in its use in accordance with these instructions. Your Dixons Portable Autoclave, operated in accordance with the manufacturers instructions, will give years of trouble free service without the need for any major servicing. Every Dixons Portable Autoclave has been manufactured to the highest quality standards by a company complying with BS EN ISO 9000 and is fully tested and ready for immediate use. Dixons Portable Autoclaves are suitable for sterilisation of: Laboratory equipment (glass and metal) Culture media Pharmaceutical preparations in sealed containers Surgical and Veterinary instruments Dressings and drapes For the sterilisation of dressings and drapes it is recommended that a Dressing Drum or Wire Mesh Basket be used. These are available as a part of the range of accessories. All Dixons Portable Autoclaves are particularly suitable for destructive sterilisation, as the operator is not restricted to a set cycle time. This can be adjusted to suit the application. This users manual consists of seven sections: 1. Installation Procedure 2. Operation 3. Sterilising Periods 4. Maintenance 5. Specification 6. Record of Inspection 7. Illustration

1. Installation Procedure 1.1 On receiving the autoclave remove all the cardboard protective covers. Unscrew the six Wing Nuts, which are holding the lid on, and remove the lid. Remove all other packaging materials from inside the autoclave. If the inspection revealed defects in the autoclave, specify below the necessary repairs or modifications which may be required: Inspection Completed Date Action Required Sign Date Sign 1.2 Ensure that the following parts are included: Autoclave body and lid complete with all fittings as per the illustration in section 7. Inner liner. Pair of liner Carrying Handles. White silicone gasket in lid. Operators manual. Test certificate. Pack of TST indicator strips. Power lead with IEC connector. 1.3 Ensure that no damage has occurred to any of the fittings paying special attention to the Pressure Gauge and Thermometer. 1.4 The autoclave is now ready for use.

6. Record Of Inspection An annual safety check will normally be sufficient unless the autoclave is in very regular use. The date of the next examination should be clearly marked on the autoclave once the examination is completed. The purpose of this form is to provide a written record of inspection. It is merely a guide as to what to look for. It does not remove the need to routinely inspect and maintain the autoclave as described in section 4. Model Type: ST 19 Serial No: Date of Examination Is the autoclave free from all signs of physical damage and distortion? Are the internal surfaces free from major 'pitting' (up to 1.5mm is acceptable)? Is the Silicone Gasket flexible, unperished and undamaged? Is the Pressure Gauge undamaged and does it read zero at atmospheric pressure? Is the Safety Valve undamaged, free moving and in working order? Are all the Wing Nuts and Drop Bolts undamaged and in working order? Are the Aircock and Draw-off Cock undamaged and in working order? Is a written set of instructions available for reference by users of the autoclave? Inspectors Signature Insert or as applicable 2. Operation Please read these operating instructions before using the autoclave to avoid any chance of misuse. The autoclave is factory set to run at 121ºC. This is the maximum setting, which is suitable for most purposes. A lower setting can be used if required. Many materials can be autoclaved at 121ºC. These include most metals, glass, silicone rubber and many plastics. If in doubt, consult the manufacturer of the instrument or equipment concerned as the manufacturer of the autoclave does not accept liability for damage of this nature. 2.1 Remove the Inner Liner. Fill the chamber of the autoclave with water up to the height of the studs. 2.2 Articles to be sterilised should be placed into the Inner Liner, a Wire Mesh Basket or a Bottle Rack. To sterilise porous loads (i.e. dressings and drapes) it is recommended that a Dressing Drum be used. The container should not be packed tightly, especially when dressings are being sterilised. It is important that steam can circulate freely. Place the Inner Liner / Wire Mesh Basket / Bottle Rack / Dressing Drum inside the autoclave. 2.3 Locate the two Drop Bolts without Wing Nuts and move these to the upright position. Check that the Lid Gasket is correctly seated in its groove on the underside of the lid. Place the lid on the autoclave so that the 2 Collared Wing Nuts are over the upright Drop Bolts. Lightly tighten down the 2 Collared Wing Nuts as a pair - one with each hand - until the slack is taken up in them. Swing up the remaining 6 Drop Bolts into position. The remaining 6 Plain Wing Nuts should now be lightly tightened in opposite pairs. This should be done as with the Collared Wing Nuts - one in each hand - until the slack is taken up. Now tighten up all the Wing Nuts in opposite pairs - Collared Wing Nuts first. Normal finger tightness is adequate. 2.4 Close the Draw-off Cock and open the Aircock approximately 6 turns.

5. Specifications 2.5 Plug the power lead into the autoclave. Plug the lead into the mains (the green light will show connection to the mains). Turn on both the Switches in the Switch Box (downwards). 2.6 When the water begins to boil, steam will start to emit from the Aircock. It will splutter at first. Close the Aircock once it has stopped spluttering and a clean jet of steam is visible. It is imperative that a clean jet of steam is visible before closing the Aircock as this ensures all the air in the autoclave is expelled. Air pockets in the autoclave will cause sterilisation to be incomplete. It is advisable to use some form of sterilisation test e.g. the TST indicator strips supplied. 2.7 The pressure and therefore temperature will now continue to rise until it reaches the preset level and the Safety Valve releases the excess pressure. 2.8 The Switch marked 'MED' should now be switched off leaving just the Switch marked 'LOW' on. 2.9 It is at this time that the sterilisation period begins. Section 3 deals with sterilisation periods. 2.10 When the sterilisation period is complete, turn off both Switches (upwards). Depending on the materials being sterilised, see section 2.11 or 2.12. 2.11 Bottles or other sealed vessels containing liquid - do not, under any circumstances, open the Draw-off Cock or the Aircock or release pressure from the autoclave in any manner. To release pressure from the autoclave at this point could cause the containers to explode. Allow the autoclave to cool until the Thermometer shows 80ºC or less. Model Type: ST 19 Capacity: 14 litres Internal Diameter: 280mm Internal Height: 230mm Overall Width: 420mm Overall Depth: 400mm Overall Height: 410mm Net Weight: 15.0Kg Chamber Material: Die Cast Aluminium LM25 Heat Source: Internal Electric Elements 230V - AC 50Hz 1.3kW & 0.7kW = 2.0kW Manual Control Design Pressure: 1.3 bar (18 psi) H T Pressure: 2.0 bar (30 psi) S W Pressure: 1.3 bar (18 psi) Complies With: H&SE PM73 (Lid Locking) BS3456 : Part 101 : 1987 (Electrical Safety) PED - 97/23/EC EMC - 89/336/EEC

and to lower the pressure (and therefore the temperature) turn it anti-clockwise. The autoclave should be left to settle for about 1 minute after each adjustment. When the desired pressure (and therefore temperature) setting is reached, tighten the locking grub screw back up to prevent the slotted adjuster moving and replace the top cap. The maximum setting allowed is 121ºC - 1.0 bar (15 psi). Maintenance - Remove the top cap, undo the locking grub screw and unscrew the Slotted Adjuster as above. Remove the spring and spindle to expose the Silicone Seal. Clean all parts and check the Silicone Seal for wear. Replace if necessary. Reassemble using a small smear of Autoclave Grease on the spindle and threads. Set the Safety Valve to the desired setting as described in the relevant section above. 4.6 Electrical Maintenance (by a qualified Electrician only) - Two elements are internally fitted - 1300W and 700W (2.0kW total) - requiring a minimum 10A fuse. Check that the terminals on the elements are tight and that the elements are securely mounted in the base. Check the Switches and light for damage. Replace if necessary. See that the IEC connector fits firmly in the socket. 4.7 Overheat Cutout - To avoid damage to the elements, should the autoclave boil dry, it is fitted with an automatic overheat cutout. This is clamped to the base of the chamber. If the device should cutout it must be manually reset. Before doing this switch off the mains to the autoclave and remove the plug. Allow the autoclave to cool down. To reset the cutout turn the autoclave upside down and remove the perforated protection plate from the bottom. The cutout will now be visible. It is a round black unit approximately 15mm in diameter with a red button protruding from the middle. To reset the cutout press this red button. You should hear an audible 'click' as the cutout is reset. Refit the protection plate and turn the autoclave the right way up. The autoclave will now work as before. 2.12 Dressings, instruments and apparatus - (providing the apparatus does not have sealed glass containers holding liquid). Warning - The water and steam that is released from the autoclave at this stage is extremely hot. Wear suitable protective equipment at this stage. Place a suitable receptacle beneath the Draw-off Cock and open the Draw-off Cock to release water and steam under pressure from the autoclave. When steam ceases to emit, close the Draw-off Cock and allow the autoclave to cool until the Thermometer shows 80ºC or less. During the cooling period a partial vacuum will form inside the autoclave. This will help in drying the contents. 2.13 When the autoclave is cooled, the Aircock should be opened approximately 6 turns. Check that the Pressure Gauge is reading zero. Unscrew the 6 Plain Wing Nuts in opposite pairs - one in each hand - 2 full turns. Now unscrew the 2 Collared Wing Nuts as a pair - one in each hand - 2 full turns. This will allow the lid to rise to a safe position, where it is still held captive, but has enough clearance to release any residual pressure still in the autoclave. Unscrew the 6 Plain Wing Nuts fully in opposite pairs - one in each hand - and swing down the Drop Bolts. Unscrew the 2 Collared Wing Nuts completely as a pair - one in each hand - and remove the lid. Do not attempt to remove the lid until all the Wing Nuts are released. 2.14 Remove the sterilised contents.

3. Sterilising Periods The following times apply to a loosely packed load. Dressings in particular should not be packed tightly as steam will not penetrate. Wire Mesh Baskets or Dressing Drums are recommended for this application. When large packs of dressings or large volumes of liquid are being sterilised, it is advisable to allow a further 10 minutes sterilisation time. This ensures adequate penetration of the materials by steam and heat. Use these times as a general guide only - always use a sterilisation test e.g. the TST indicator strips supplied. Instruments and Equipment 121ºC 15 minutes Dressings and Drapes 121ºC 30 minutes Liquid in Sealed Containers (0ml - 50ml) 121ºC 20 minutes Liquid in Sealed Containers (50ml - 100ml) 121ºC 20 minutes Liquid in Sealed Containers (100ml - 200ml) 121ºC 20 minutes Culture Media (up to 1 litre) 121ºC 15 minutes Notes on sterilisation of Culture Media: 1. Always follow the manufacturer's instructions. 2. Use volumes up to 1 litre. 3. Use similar volumes in the same load. 4. After cycle test for sterility. 5. Check microbiological performance before use. 4. Maintenance UK users - this autoclave comes within the scope of 'The Pressure Systems and Transportable Gas Containers Regulations 1989' and should be inspected and maintained accordingly. General maintenance should be carried out by a competent person only, as and when deemed necessary. 4.1 Lid Gasket - Check the white silicone Lid Gasket for distortion or wear and tear. The Lid Gasket is located in the groove on the underside of the lid. Check that it has not become brittle. Replace the Lid Gasket with a new one if necessary. 4.2 Body Rim - Check the rim of the body where the Lid Gasket seats for damage to the metal casting which would cause the lid seal to leak. If the damage is only minor, then the rim can be repaired by filing and smoothing with emery cloth. Major damage should be referred to the manufacturer or a qualified service engineer. 4.3 Draw-off Cock - Check the Draw-off Cock for signs of leaking around the seals and from the valve. Replace the seals or complete Draw-off Cock with a new one if necessary. 4.4 Cleaning - The use of alkalis (e.g. sodium bicarbonate) may cause corrosion of the pot and lid and should therefore be avoided. Use normal household detergent to clean the interior of the autoclave. 4.5 Safety Valve Adjustment and Maintenance - The Safety Valve is factory set to hold a temperature of 121ºC. This is a maximum, but can be adjusted if required to a lower setting by a competent person only. Adjustment - Unscrew the top cap and loosen the locking grub screw. Set a gap of about 4mm between the slotted adjuster and the top of the body. Bring the autoclave up to working pressure. Turn off the Switch marked 'MED'. Warning - The Safety Valve will be hot at this point. The pressure at which the Safety Valve releases steam can now be adjusted by turning the slotted adjuster. To raise the pressure (and therefore the temperature) turn the slotted adjuster clockwise,