The cracking behaviour of reinforced concrete beams under static and dynamic loading

Similar documents
Deformation Capacity of RC Structural Walls without Special Boundary Element Detailing

In-plane testing of precast concrete wall panels with grouted sleeve

Modelling of RC moment resisting frames with precast-prestressed flooring system

The Development of Strain Penetration in Lightly Reinforced Concrete Shear Walls

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 2, 2011

Reinforced concrete beam-column joints with lap splices under cyclic loading

Overview of Presentation. SCBFs are Conceptually Truss Structures

SEISMIC TEST OF CONCRETE BLOCK INFILLED REINFORCED CONCRETE FRAMES

DUCTILITY REQUIREMENTS FOR BUILDINGS

INHERENT DUCTILITY OF REINFORCED CONCRETE SHEAR WALLS WITH NON-SEISMIC DETAILING

SEISMIC RETROFITTING OF REINFORCED CONCRETE COLUMNS USING CARBON FIBER REINFORCED POLYMER (CFRP)

Seismic Detailing of RC Structures (IS: )

Behavior and Strength of Slab-Edge Beam-Column Connections under Shear Force and Moment

Gravity Load Collapse of Reinforced Concrete Columns with Brittle Failure Modes

THE PERFORMANCE OF CONCRETE GROUND FLOOR SLAB REINFORCEMENT TO CONTROL SHRINKAGE CRACKING. D H Chisholm 1

Seismic Retrofit Of RC Columns With Inadequate Lap-Splice Length By External Post-Tensioned High-Strength Strips

REHABILITATION OF RC BUILDINGS USING STRUCTURAL WALLS

Pile to Slab Bridge Connections

LATERAL LOAD BEHAVIOR OF UNBONDED POST-TENSIONED HYBRID COUPLED WALLS. Qiang SHEN Graduate Research Assistant. Yahya C. KURAMA Assistant Professor

Journal of Asian Scientific Research EVALUATION OF RECTANGULAR CONCRETE-FILLED STEEL-HOLLOW SECTION BEAM-COLUMNS

Performance based Displacement Limits for Reinforced Concrete Columns under Flexure

ME -215 ENGINEERING MATERIALS AND PROCESES

SEISMIC PERFORMANCE OF CONCRETE TILT-UP BUILDINGS: CURRENT WALL-TO-SLAB CONNECTIONS

AN ANALYSIS OF THE BEHAVIOR OF HYBRID STEEL BEAM RC COLUMN CONNECTION

FINITE ELEMENT ANALYSIS OF REINFORCED CONCRETE BRIDGE PIER COLUMNS SUBJECTED TO SEISMIS LOADING

EXPERIMENTAL STUDY ON CONFINED CONCRETE OF THIN COLUMN SECTIONS (070S)

PERFORMANCE OF LAP SPLICES IN CONCRETE MASONRY SHEAR WALLS UNDER IN-PLANE LOADING

Fagà, Bianco, Bolognini, and Nascimbene 3rd fib International Congress

SEISMIC RETROFIT OF BEAM-COLUMN JOINTS WITH FRP SHEETS

On Improved Performance Of Eccentrically Braced Frames With Replaceable Shear Link

Reinforced Concrete Design. A Fundamental Approach - Fifth Edition

Investigation on Behaviour of Reinforced Concrete Beam Column Joints Retrofitted with FRP Wrapping

Effect of beam dimensions on structural performance of wide beam-column joints

EFFECTS OF LOADING HISTORY ON CYCLIC PERFORMANCE OF STEEL RBS MOMENT CONNECTIONS

SEISMIC RETROFIT OF A TYPICAL REINFORCED CONCRETE BUILDING THROUGH FRP JACKETING OF EXTENDED RECTANGULAR COLUMNS

True Stress and True Strain

Development and research of eccentrically braced frames with replaceable active links

A DESIGN SCHEME OF STEEL CONNECTIONS FOR PREVENTING BRITTLE FRACTURE

CFT Column-to-Cap Beam Connections for. Accelerated Bridge Construction in Seismic Regions. Lisa Marie Berg. Master of Science in Civil Engineering

ULTIMATE LOAD-CARRYING CAPACITY OF SELF-ANCHORED CONCRETE SUSPENSION BRIDGE

STRENGTH OF MATERIALS laboratory manual

Structural Systems with Enhanced Seismic Resiliency Using High-Performance Materials

Sabah Shawkat Cabinet of Structural Engineering 2017

PERFORMANCE STUDY OF RETROFITTED GRAVITY LOAD DESIGNED WALL FRAME STRUCTURES (SC-140)

CYCLIC BEHAVIOR OF SLENDER R/C COLUMNS WITH INSUFFICIENT LAP SPLICE LENGTH

Strengthening of infilled RC frames by CFRP

Analysis of Flexural Behaviour of Singly and Doubly Reinforced High Strength Concrete Beams Using Ansys

Hybrid Reinforced Concrete Frame Building with Pumice Brick Masonry Infill under Static Lateral Loading

NON-LINEAR FEM ANALYSIS FOR CES SHEAR WALLS

STRUCTURAL PERFORMANCE OF RC BEAMS AND BEAM-COLUMN SUBASSEMBLAGES USING REINFORCEMENT WITH SLEEVE JOINTS AT THE END OF BEAMS

Nonlinear Finite Element Modeling & Simulation

FLEXURAL IMPROVEMENT OF PLAIN CONCRETE BEAMS STRENGTHENED WITH HIGH PERFORMANCE FIBRE REINFORCED CONCRETE

USE OF HIGH-STRENGTH REINFORCEMENT FOR EARTHQUAKE- RESISTANT CONCRETE STRUCTURES

CYCLIC TESTING OF BOLTED CONTINUOUS I-BEAM-TO-HOLLOW SECTION COLUMN CONNECTIONS

RESPONSE OF SUBSTANDARD REINFORCING DETAILS T CONNECTIONS UPGRADED WITH CONCRETE COVERS AND CFRP

22. DESIGN OF STEEL BRACED FRAMES Eccentrically Braced Steel Frames

RESEARCH PROJECT AT UNIVERSITY OF NEVADA, RENO

FINITE ELEMENT MODELING OF NON-DUCTILE REINFORCED CONCRETE COLUMNS

EXPERIMENTAL STUDY ON RC COLUMNS RETROFITTED BY FRP AND SUBJECTED TO SEISMIC LOADING

Experimental study on seismic behavior of composite concrete and

Original Publication: International Journal of High-Rise Buildings Volume 5 Number 3

3. CLASSIFICATION AND IMPLICATIONS OF DAMAGE

NONLINEAR FINITE ELEMENT ANALYSIS OF NON- SEISMICALLY DETAILED INTERIOR RC BEAM-COLUMN CONNECTION UNDER REVERSED CYCLIC LOAD

PERFORMANCE-BASED SEISMIC DESIGN OF BRACED-FRAME GUSSET PLATE CONNECTIONS

Concrete-filled fiber reinforced polymer tube-footing interaction in bending

Design for earthquake-resistent reinforced concrete structural walls

EFFECT OF VENEER JOINT REINFORCEMENT ON BRICK TIE EMBEDMENT

Special Reinforced Concrete Structural Walls

EXPERIMENTAL TESTING OF PRECAST CONCRETE PANEL CONNECTIONS

SEISMIC RESPONSE OF MULTIPLE-ANCHOR CONNECTIONS TO CONCRETE

BEHAVIOR OF REINFORCED CONCRETE BEAM WITH OPENING

Bijan Khaleghi, Ph, D. P.E., S.E.

Experiment of Reinforce Concrete Beams at Different Loading Rates

Experimental Study on Wall-Frame Connection of Confined Masonry Wall

Modeling of Coupled Nonlinear Shear and Flexural Responses in Medium-Rise RC Walls

Moment curvature analysis of concrete flexural members confined with CFRP grids

Load Bearing and Deformation Capacity of Fire Resistance Steel Tubular Columns at Elevated Temperature

Seismic Evaluation and Retrofit of Beam- Column Joints of Mid-America Bridges Part 2: Steel Sheet and Plate Retrofit

Comparative Study of R.C.C and Steel Concrete Composite Structures

Comparison of Prefabricated Cage System with Existing Reinforcement Methods in Concrete Columns

SEISMIC PERFORMANCE OF REINFORCED CONCRETE COLUMNS WITH 90 DEGREE END HOOKS FOR SHEAR REINFORCEMENT UNDER HIGH SPEED LOADING

EXPERIMENTAL BEHAVIOUR OF STRAIGHT AND HOOKED SMOOTH BARS IN EXISTING R.C. BUILDINGS

SHAKE TABLE TESTING OF BRIDGE REINFORCED CONCRETE COLUMNS UNDER COMBINED ACTIONS

Reduction of Natural Frequency due to Flexural Cracks or Shear Cracks in Reinforced Concrete Members

Seismic Performance of Reinforced Concrete Eccentric Beam-Column Connections with Floor Slabs

SEISMIC EFFECTS ON COUPLED SHEAR WALL STRUCTURE BY COUPLING BEAMS WITH SIDE BOLTED STEEL PLATES

REVIEW ON SHEAR SLIP OF SHEAR KEYS IN BRIDGES

ESECMASE - SHEAR TEST METHOD FOR MASONRY WALLS WITH REALISTIC BOUNDARY CONDITIONS

RETROFITTING OF COLUMNS WITH RC JACKETTING AN EXPERIMENTAL BEHAVIOR

Analytical Investigation of Seismic Performance of Exterior RC Beam-Column Joints Rehabilitated with New Scheme

A Guide for the Interpretation of Structural Design Options for Residential Concrete Structures

Properties in Shear. Figure 7c. Figure 7b. Figure 7a

SEISMIC PERFORMANCE AND RETROFIT OF BRIDGE FOOTINGS. David I. McLean 1

NLFEA Fire Resistance of 3D System Ceiling Panel

BEHAVIOR OF CASTELLATED BEAM COLUMN DUE TO CYCLIC LOADS

ctbuh.org/papers CTBUH Recommendations for the Seismic Design of High-Rise Buildings

CYCLIC BEHAVIOUR OF SANDWICH CONCRETE BEAM UNDER FLEXURAL LOADING

A PRODUCT FROM KANTAFLEX (INDIA) PVT LIMITED

USE OF CFRP ANCHORS TO STRENGTHEN LAP SPLICES OF RECTANGULAR RC COLUMNS

NON-LINEAR FINITE ELEMENT MODELING OF RC FRAME-MASONRY WALL INTERACTION UNDER CYCLIC LOADINGS

Transcription:

The cracking behaviour of reinforced concrete beams under static and dynamic loading J.A. Huffadine, A.G. van Bysterveldt, G.C. Clifton & G.W. Ferguson Department of Civil Engineering, University of Auckland, Auckland 2015 NZSEE Conference ABSTRACT: Following the 2010 and 2011 earthquakes in Canterbury it was observed that many plastic hinge zones in reinforced concrete beams of multi-story buildings performed unexpectedly. It was seen that a few wide cracks developed, rather than the expected large number of hairline cracks. The purpose of this research was to investigate the effect of different loading types and rates on the cracking pattern in the concrete and strain demand along the reinforcing bar within the plastic hinge zone of a typical beam. This was achieved through conducting tests on concrete prisms simulating the conditions around an individual bar in a beam with typical beam reinforcement content under monotonic and cyclic loading at static and dynamic loading rates. A strain hardness relationship was developed in order to obtain the strains along the reinforcing bar post testing. The results from the static and dynamic tests show that faster rates of loading induce a smaller number of cracks then do static loading rates. There was no observed significant difference between monotonic and cyclic loading. The strain along the reinforcing bar was not uniform and this resulted in concentrated strains developing at crack locations. This research shows that the current strategy of repair of damaged concrete buildings needs to be reconsidered due to this markedly non-uniform strain distribution. 1 INTRODUCTION Following the 2011 Christchurch earthquake it was found many beams in moment-resisting reinforced concrete framed buildings performed unexpectedly. When a beam is subject to a significant seismic action it has been expected, based on many previous laboratory tests, that closely spaced distributed cracking will form along the length of the plastic hinge zone. This allows the strain caused by the cracks to be spread evenly over this length and this was assumed for design. The cracking pattern seen in beams in the 2011 Christchurch earthquake was substantially different from what was expected based on previous experimental testing (Bull 2013). Instead of evenly distributed cracking forming in the beams it was observed that only a small number of widely spaced large cracks formed. These large cracks put an increased strain demand on the steel that runs across the crack, reducing the postearthquake capacity of the structure for a given plastic hinge rotation. This has made understanding why this unexpected cracking behaviour occurred in the Christchurch earthquakes a high priority. 1.1 Objectives The objectives of this research were to; Determine how different loading types affect the cracking pattern and the strain profile produced in the plastic hinge zones of reinforced concrete beams. Develop a robust strain-hardness relationship for a Grade 500 deformed 12mm reinforcing bar made from straight bar (diameters typically used in full scale beams are made from straight bar not coil and the properties are different). Paper Number O-01

2 METHODOLOGY The objectives of this research were achieved through two experimental stages. The first stage was developing a robust strain hardness relationship through performing tensile tests on the reinforcing bar at particular strains, and then subsequently testing the hardness of the bar. The second stage included testing reinforced concrete prisms with loading types as follows; monotonic static, cyclic static, monotonic dynamic and dynamic cyclic. Once loaded and unloaded, the longitudinal reinforcing bars were removed from the concrete prisms and hardness tested in a benchtop hardness tester. From the specimens hardness, a strain profile along the bar for each loading type was developed. 2.1 Strain hardness relationship The direct tension tests of DH12 bars were conducted to predetermined plastic strains. The hardness of these bars was then tested using the Rockwell G Hardness machine, to develop the relationship between plastic strain and hardness of the reinforcing bars. This relationship provided a platform for which the hardness reading results from the concrete prisms tests could be correlated to the associated plastic strains based on the strain-hardness relationships developed. This technique of using a strainhardness profile to approximate the plastic strain in the reinforcing bar was previously used in research conducted by Van and Patel (2013). The direct tension tests were performed on the 12mm reinforcing bar in the 100 kn Ingstron tensile testing machine. The reinforcing bar was gripped at each end and each bar strained to 3.5, 7, 10.5 or 15%. The hardness of these bars was then tested and plotted against the known plastic strains in order to develop the robust strain-hardness relationship for DH12 reinforcing bars. 2.2 Concrete prism testing A concrete specimen with cross-sectional area of 100x100mm was constructed and tested axially under pure tension and compression with loading types as follows; monotonic static, cyclic static at an ascending rate, monotonic dynamic and dynamic cyclic at an ascending rate. The reinforcing bar was then removed from the concrete and the hardness along the bar determined. From the specimens hardness along the bar, a strain profile versus cracking pattern was developed for the different loading types. The test setup was designed to represent a section of a beam with approximately 2.0% reinforcing content in the plastic hinge zone of a moment resisting frame. In a small segment of the beam close to the column face the forces acting on the element are almost direct tension and compression and it was this environment that was captured in the prism tests.. Table 1. Concrete prism construction details. Prism Dimensions Longitudinal Reinforcing Size Stirrup Size Stirrup Spacing Concrete Cover Aggregate Size Concrete Strength Concrete Prism 100x100x756 mm DH12 R4 50mm 14mm 10mm 45MPa Eight 100x100mm specimens were cast into formwork and each with 14mm of concrete cover as well as a notch that acted as a crack initiator. The specimens contained one DH12 longitudinal bar and 4mm stirrups at 50mm spacing as can be seen in Figure 1. Due to the specimen containing four free edges, the longitudinal bar had less restraint and was prone to buckling, not normally the case in typical beams. Therefore it was deemed necessary for the stirrups to have a spacing of 50mm. At each 23

end of the concrete specimens the reinforcing bar was welded to a 10mm steel plate which contained 4 bolts. All concrete specimens had a specified concrete strength of 45MPa and 10mm aggregate size. The specimens were set for around 28 days in order to allow strength gain of the concrete. In the monotonic tests the concrete specimens were subject to increasing tensile loads until the reinforcing bar ruptured. For the cyclic tests, the loading regime began with 1mm displacement followed by 1.5mm and continuing to increase by 25-50% with each increment. Three cycles at each displacement were conducted before incrementally increasing the displacement. Figure 1. Concrete prism test setup. Each of the loading types in Table 2 represents the different tests that took place. Each of these tests was repeated twice to ensure accuracy of results. The loading rates used in the dynamic tests lie between the middle and upper end of earthquake loading rates while the static tests loading rates are well within the pseudo-static limits (Pajak, 2011). Table 2. Loading types and rates Loading Type Loading Rate Strain Rate Monotonic Static 0.05mm/s 10-4 /sec Cyclic Static 0.05mm/s 10-4 /sec Monotonic Dynamic 26.5mm/s 0.05/sec Cyclic Dynamic 26.5mm/s 0.05/sec Once the tests were conducted, the reinforcing bar was removed, milled and cut into lengths of less than 100mm while ensuring crack locations remained identified. The hardness along the bar was then tested to determine the plastic strain along the bar and in particular the strain at the crack locations was measured more densely in a micro-hardness traverse. This was done using the Rockwell G hardness machine. The hardness reading obtained was used in conjunction with the strain hardness relationship developed earlier to obtain plastic strain values along the reinforcing bar. The plastic strain values and crack locations were matched and comparisons between different loading types took place in order to determine the effect these loading types have on the crack pattern and ultimately the strain in the reinforcing bar. 24

3 RESULTS 3.1 Steel tensile test results Figure 2 shows the results from the steel tensile tests. Reinforcement derived from straight bar was used throughout this research, as coiled bar is only available in diameters up to 16mm and beam members typically use bar sizes greater than this. The measured yield point of the steel was 520MPa. The measured ultimate tensile strength of the bar was 620MPa. The bar fractured at a measured strain of 13.8%. As seen in Figure 2, the steel bar used in this research has a small post-yield increase in strength and therefore undergoes limited hardening for a significant increase in plastic strain. 3.2 Hardness Strain Relationship Figure 2. Stress strain relationship of a DH12 reinforcing bar. As seen in Figure 3, there is a clear trend showing that an increase strain results in an increase in the hardness of the DH12 reinforcing bar. A hardness value of 71.5 ± 3% or below gives no indication of the strain in the reinforcing bar. In this region which corresponds to a strain up to 2.5% ± 0.5%, the bar has only undergone elastic deformation and therefore no strain hardening has occurred. This means the hardness in the bar has not changed from its unstrained state. Where a hardness reading is obtained that lies in this region we cannot be sure what extent of elastic or plastic deformation the bar has undergone. As seen in the strain hardness relationship in Figure 3, hardness increases with increasing strain up to failure of the bar at 13.8% strain. Hardness readings indicating a strain higher than this are not valid, so where a hardness reading corresponds to a strain higher than this, the value has been limited to 13.8%. The error bars from the data relating to the strain hardness relationship as seen in Figure 3 are the maximum and minimum values recorded for hardness. These are large in relation to the total hardness range; however this is within the variability of the measuring procedure. In the region of strain between 2.5% ± 0.5% and 13.8% ± 0.5% the hardness can be related to the plastic strain for a DH12 reinforcing bar through the equation below: HRG = 2.93 ln(ɛ) + 69.80 (1) Where 2.5% ± 0.5% < ɛ < 13.8% ± 0.5%; HRG = Rockwell G Hardness; ɛ = Plastic Strain 25

3.3 Concrete Prism Test Results Figure 3. Strain hardness relationship of DH12 reinforcing bar. Eight concrete prism tests were conducted. From the compression and split tensile tests it is estimated that the concrete reached an average compressive strength of 36MPa and tensile strength of 4.8MPa. Figures 5 to 8 show the strain profiles along the length of the reinforcing bars and the cracked profile of the specimens for each of the different loading cases. From the strain profiles it can be seen that the bars did not strain uniformly. The peak strains in the bar correspond to the locations of the cracks in the concrete. The strain drops off on either side of the crack location where the load is transferred from the reinforcing bar into the concrete. It was observed that the crack caused by the crack initiator did not match up directly with a peak strain. When cracks form they naturally spread from the reinforcing bar into the concrete and propagate to the surface. It is thought that the crack initiator caused the crack at this location to propagate from the surface of the concrete inwards on a 45 degree angle causing the corresponding peak strain from this crack to be skewed to the side of the crack initiator. 3.3.1 Static monotonic In the static monotonic tests nine primary cracks were observed with secondary cracks developing towards the end of the test. The longitudinal bar fractured in the heat affected zone at a tensile load of 74kN and a displacement of 47mm. Figure 4. Static monotonic strain profile and cracking pattern. 26

3.3.2 Static cyclic In the static cyclic tests, five to six primary cracks were observed with minor secondary cracks developing along the length of the member subsequent to the primary cracks. The first static cyclic test failed due to the longitudinal bar fracturing in the heat affected zone of the bar. The second test was stopped due to excessive buckling of the member. The maximum displacement reached was 20mm. Both tests underwent approximately 25 cycles before failure of the member occurred. 3.3.3 Dynamic monotonic Figure 5. Static cyclic cracking pattern and strain profile. In the dynamic monotonic tests, five to six primary cracks were observed with minor secondary cracks developing along the length of the member. The longitudinal bar fractured on average 43mm from the base of the endplate. The maximum displacement reached was 34-46mm. 3.3.4 Dynamic Cyclic Figure 6. Dynamic monotonic strain profile and cracking pattern. In the dynamic cyclic tests, five primary cracks were observed with no secondary cracks developing. The first test was stopped due to excessive buckling of the member. The second test was stopped due the maximum compression load of 110kN on the MTS being reached. Before the tests were stopped the maximum increase in displacement reached was 20mm and approximately 25 cycles had been completed. 27

Figure 7. Dynamic cyclic strain profile and cracking pattern. 4 DISCUSSION 4.1 Comparison of static and dynamic tests From the figures showing strain along the reinforcing bars it is apparent that the static tests had more primary and secondary cracks develop than the dynamic tests. Furthermore the reinforcing bar acted in a more ductile manner in the dynamic tests, in contrast to the findings of Chung and Shah (1989). This was evident in the failure of the reinforcing bar as necking occurred in the dynamic tests as seen in Figure 8. Additionally, both the static and dynamic tests reached a similar total displacement, however the dynamic tests had much fewer cracks form. This would mean that the bar had to elongate more in these few wide cracks, demonstrating a ductile behaviour. Figure 8. Bar Fracture Monotonic Dynamic (Left), Monotonic Static (Right). In research conducted by Pajak (2011) it was seen that as the loading rate increases, the concrete tensile strength also increases. This may have contributed to the decreased number of cracks forming in the dynamic tests as it would become increasingly difficult to initially crack the concrete. Degradation of the bond between the concrete and reinforcing bar may have been more prominent in the static tests as it takes time for the bond to break down. When this degradation occurs, it allows the strain to propagate along the reinforcing bar and progressively yield. This is a likely contributing factor to the higher number of cracks in the static tests. 4.2 Comparison of monotonic and cyclic tests In comparing the monotonic tests with the cyclic tests, it can be seen that the monotonic tests had more prolific cracks. This however was due to the cyclic tests only making 20mm displacement before the specimens buckled or the maximum compression load the testing machine could handle was reached. Buckling of the cyclic tests occurred due to a crack forming between the face of the steel plate and concrete. This reduced the end fixity of the specimens and allowed rotation at these points. There appears to very little difference between the cracking patterns in the monotonic and cyclic loading, however further research conducted with greater end fixity to remove the buckling of the 28

specimen is needed. It was observed in the cyclic tests that the stains obtained from the strain hardness relationship are relatively low in comparison to the monotonic tests. This may be due to the reinforcing bar undergoing less extension than the monotonic tests and therefore a lower strain. 4.3 Canterbury Earthquakes It was found that the cracking pattern observed in this research was very similar to that seen in the Christchurch earthquakes, whereby, widely spaced large cracks formed in the plastic hinge zone instead of evenly distributed fine cracking forming. As the longitudinal reinforcing bar is strain hardened, the strength of the bar in the cracked region increases, which moves the yield further along the reinforcing bar making it more likely that another crack will form adjacent to the first crack. However, as can be seen in Figure 8, the reinforcing bar used in this research had a very small increase in strength following yielding and therefore underwent very little hardening for a significant increase in strain. This low ratio of f u to f y, the high tensile strength of the concrete and the high bond strength between the bar and the concrete made it unlikely that a large number of cracks would form along the length of the concrete prism and agrees with the cracking pattern seen in this research. The strain hardness relationship that has been developed could potentially be used in buildings that have undergone an earthquake as a single reinforcing bar could be carefully removed from the plastic hinge zone of a beam and hardness tested to evaluate the strain in the bar. This would give us a better understanding of the post-earthquake capacity of the beams in a structure. 5 CONCLUSIONS The reinforcing bar did not strain uniformly. The strain in the bar was concentrated in the crack locations. It was observed that there were more cracks in the static tests than there were in the dynamic tests. The cracking pattern of widely spaced large cracks seen in beams in the Canterbury earthquakes is very similar to what has been observed in these tests. The central reinforcing bar in the dynamic tests acted in a more ductile manner than in the static tests. 6 REFERENCES Bull, D.K. 2013. Earthquakes and the effects on structures: Some of the lessons learnt. Australian Journal of Structural Engineering, 14(2): 145-166. Chung, L. & Shah, S. P. (1989). Effect of loading rate on anchorage bond and beam-column joints. ACI Structural Journal, 86(2): 132-142. Pajak, M. 2011. The influence of the strain rate on the strength of concrete taking into account the experimental techniques. Architecture Civil Engineering Environment, 3 Van, B. & Patel, V. 2013. Improving the ductility of reinforced concrete shear walls by altering the deformation patterns of reinforcing steel. Paper Presented at Part 4 Projects 2013, Auckland. 29