Quantitative techniques to discriminate petroleum oils using LED-induced fluorescence

Similar documents
A LIDAR SYSTEM FOR REMOTE MEASUREMENT OF OIL FILM THICKNESS ON SEA SURFACE *

Fluorometric method for determining the thickness of acrudeoilfilmformed on the water surface


Bioinstrumentation Light Sources Lasers or LEDs?

The Raman effect, discovered in 1928 by C.V. Raman in his

Measuring Ocean Color: The Basics

Characterization of laser-material interaction during laser cladding process P.-A. Vetter,* J. Fontaine,* T. Engel," L. Lagrange,& T.

NIR Checkmaster Near-infrared spectroscopy On-line analysis of active ingredients during tablet production

Miniaturised SAC Measurement for Continuous Monitoring of Water Quality

Advantages of Photodiode Array

Fig1: Melt pool size of LAMP vs. µlamp. The LAMP process s melt pool is x the area of the LAMP s melt pool.

MAKE NO MISTAKE, IT S UV THAT EVERYONE CAN USE. LAMBDA 265 / 365 / 465 UV/Vis Solutions

AlgaeTorch. The handy measurement instrument for rapid deployment. Fast and simple algae monitoring

Physical structure of matter. Monochromatization of molybdenum X-rays X-ray Physics. What you need:

Applicability of Hyperspectral Fluorescence Imaging to Mineral Sorting

In-situ Heating Characterisation Using EBSD

Plastic Coated Silica/Silica (Low OH) FIBER CROSS SECTION Polyimide and Acrylate Coated. Nylon and Tefzel Coated

FLUORESCENCE SPECTRA OF OIL AFTER IT CONTACTS WITH AQUATIC ENVIRONMENT

Light and the Aquatic Ecosystem

Real-time tablet API analysis: a comparison of a palm-size NIR spectrometer to HPLC method

Performance of the Micro Photon Devices PDM 50CT SPAD detector with PicoQuant TCSPC systems

Cavity Filters. KIGRE, INC., 100 Marshland Road, Hilton Head, SC 29926, USA PH: FAX: Web:

CREOL, The College of Optics & Photonics, University of Central Florida

R O EARLY DETECTION SYSTEM FOR OIL ON WATER

Supporting Information to Carbon Nanodots Towards a Comprehensive Understanding of their Photoluminescence

lumasense IMPAC Pyrometers Product Overview Highly Accurate Infrared Thermometers for Non-contact Temperature Measurements

Picosecond Transient Absorption Spectroscopy System. picotas

What is Hydrologic Optics? Optics Attentuation Inherent properties Scatter Absorption Apparent properties

Will your product last? Put it to the test.

Laser Welding of Engineering Plastics

Transmission Mode Photocathodes Covering the Spectral Range

Micophotometric Control of Particles and Inhomogeneities in Flowing Polymer Melts during Extrusion Processing

In-Situ Characterization During MOVPE Growth of III-Nitrides using Reflectrometry

Experimental study on laser marking of alumina

Time-resolved Measurements Using the Agilent Cary Eclipse Fluorescence Spectrophotometer A Versatile Instrument for Accurate Measurements

Innovations To Meet Your Needs

Understanding Optical Coatings For Military Applications

At wavelength characterization of EUV and soft X-ray gratings

Sapphire SF: Low-Noise Ultra-Narrow Bandwidth Performance Delivers Superior Raman Spectroscopy Results

16.2 Scanning Infrared Spectrometers

A Survey of Laser Types. Gas Lasers

Scintillating Optical Fibers

Satoshi Kawata. Near-Field Optic s and Surface Plasmon Polaritons

Study of Spinning Speed, Multilayer Coating and Formaldehyde Effect on Preparation of Xerogel Film Doped with Laser Dyes

Quantitative thickness measurement of dual layer materials using X-ray absorption-based technique

DeltaPro. DeltaFlex FORENSICS PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS RAMAN

Measuring trace impurities in HyCO, regeneration hydrogen and inert gases Los Gatos Research (LGR)

High Purity Simultaneous Cell Sorting of Nano and Large Phytoplankton Using the MoFlo Astrios EQ

Laser Ultrasonics 2010 Laser-based ultrasonic-emission sensor for in-process monitoring during high-speed laser welding

Laser Produced Plasma for Production EUV Lithography

Fs- Using Ultrafast Lasers to Add New Functionality to Glass

REVIEW OF LASER PLASTIC WELDING PROCESS

OptiLIS 201 & 301. Online multi-parameter continuous water analyzers. OptiLIS 201 OptiLIS 301

Supplementary Figure 1 Scanning electron micrograph (SEM) of a groove-structured silicon substrate. The micropillars are ca. 10 μm wide, 20 μm high

Hard Coated Silica/Silica (Low OH) Radius

Image Capture, Processing and Analysis of Solar Cells for Engineering Education

Cleaning Validation PRODUCT OVERVIEW

Instrumentation in Raman Spectroscopy: Elementary Theory and Practice 6. Coupling with other technique Raman-LINF-LIBS

Spectroscopy Fiber Optic Probes for In-line Analytical Analysis

Application of Gliders for Near-Real Time METOC Data Collection Capability for Battlespace Characterization

R&D ACTIVITIES AT ASSCP-BHEL,GURGAON IN SOLAR PV. DST-EPSRC Workshop on Solar Energy Research

Standard Optics Information

VACUUM VIEWPORTS. Introduction... I 03 KF Viewports... I 09 I 01. VACUUM / Components & Consumables

Quantum Dot applications in Fluorescence Imaging for Calibration and Molecular Imaging

Standard fiber offering.

Introduction of Biosensors

AFM-Raman Characterization of Pharmaceutical Tablets

Confocal Microscopy Analyzes Cells

Mid Infrared Spectroscopy for Rapid and Cheap Analysis of Soils

Low Divergence atomic beam using laser ablation of thin film

DETECTION OF CONTAMINANTS ON CFRP SURFACES A NECESSITY FOR COMPOSITE REPAIR? ABSTRACT

Experiment 2b X-Ray Diffraction* Optical Diffraction Experiments

This is an electronic reprint of the original article. This reprint may differ from the original in pagination and typographic detail.

Onsite FTIR quantitative analysis of water in mineral-based oils using a novel water stabilization technique

Advances in Intense Pulsed Light Solutions For Display Manufacturing. XENON Corporation Dr. Saad Ahmed Japan IDW 2016

Near Infrared and Raman Spectroscopy for in-line Monitoring of Polymers - Applications in the Polymer Industry

THE PAST, PRESENT, AND FUTURE OF LIGHTING

LOW TEMPERATURE PHOTONIC SINTERING FOR PRINTED ELECTRONICS. Dr. Saad Ahmed XENON Corporation November 19, 2015

New Developments in Measuring Low Silicon in Process Piping Using Handheld X-ray Fluorescence (XRF)

Coatings. Ion Assisted Deposition (IAD) process Advance Plasma Source (APS) plasma-ion assisted Deposition. Coatings on Optical Fibers

Multiphoton lithography based 3D micro/nano printing Dr Qin Hu

RightWave EDF Family. The Right Fiber Diet for Optical Amplifier Design. OFS Your Optical Fiber Solutions Partner

POLLUTION SURVEILLANCE AND DATA ACQUISITION ABSTRACT INTRODUCTION

CyFlow Space Your flexible flow cytometer

Non-contact temperature measurement from 50 C to 2200 C

Discharge Characteristics of DC Arc Water Plasma for Environmental Applications

CyFlow Space Your flexible flow cytometer

AS... UV FIBERS AS... IR FIBERS GRADED INDEX FIBERS PCS - FIBERS HPCS - FIBERS SINGLE-MODE FIBERS CAPILLARIES

Navigating the Turbidity Units Standards Around Water Quality Monitoring

Simultaneous multi-color, multiphoton fluorophore excitation using dual-color fiber lasers

Zenith Polymer Diffuse Reflectance Standards, Targets and Materials. ... your Partner in Lighting Technology!

Greenhouse Gas Measurement Technology

Online Wastewater Process Monitoring

one Smart Sustainable Solar

Supporting Information

Size quality report for the Zetasizer Nano

Application of non-destructive optical techniques in the detection of surface and sub-surface defects in sapphire

ICP-OES. Varian Vista-MPX CCD Simultaneous ICP-OES

BASF Corporation. Abstract. Introduction. Basic Principles for LW of Thermoplastics. Non-Contact Laser Welding (NCLW)

Using a standard Penning Gauge as a powerful means of monitoring and feedback control

Transcription:

Water Pollution VIII: Modelling, Monitoring and Management 255 Quantitative techniques to discriminate petroleum oils using LED-induced fluorescence V. Rostampour & M. J. Lynch Curtin University of Technology, Australia Abstract In-situ LED-induced fluorescence analysis of oils on water was performed by examining the fluorescence spectrum of various Australian crude oils and some refined oil products. Crude oils and other refined oil were discriminated using non-contact fluorescence-based techniques. The spectral distribution of the fluorescence emission, which contains obvious diagnostic potential, has been used as a quantitative technique to differentiate oil products. The key factors used in these quantitative techniques are; (i) spectral shape, (ii) the wavelength of maximum intensity and (iii) fluorescence spectral width. The first discriminating technique applied is the green-yellow quotient ( I G Y = I 49 I 575 ) and the blue-yellow quotient ( I B Y = I 42 I 575 ). The dualwavelength excitation was employed in the laboratory to discriminate crude and refined oils. In this technique, oil slicks (on water) were exposed to two different excitation illumination wavelengths. All oil samples were illuminated by several UV and visible excitation sources. The four crude oils and other petroleum products were easily differentiated by applying the ratio of two fluorescence spectral bands excited by 528 nm and 45 nm. While theses techniques appear to be sensitive enough to discriminate different crude oils and other refined oil products in the non-contact fluorescence measurement, the selected excitation wavelength range chosen was not the optimum wavelength for fluorescence of crude oil. More studies need to be performed using additional crude oil samples and shorter excitation wavelengths. Keywords: LED-induced fluorescence, oil pollution, crude oil, remote sensing. doi:1.2495/wp6261

256 Water Pollution VIII: Modelling, Monitoring and Management 1 Introduction Fluorescence spectra provide valuable information for a variety of purposes for terrestrial and aquatic environments. The major advantages of fluorescence sensing are the possibility of obtaining real-time, low cost, non-contact, and high sensitivity information with high spectral resolution from the target of interest. Fluorescence remote sensing techniques have been used in a variety of environmental studies such as; water pollution [1, 2], turbidity [3], diagnostic of oil pollution [4], chemical pollution [5], pigment composition of phytoplankton [6] and spectral characterization of dissolved organic matter [7]. Fluorescence techniques have been used for decades as tools for the characterization and analysis of hydrocarbon oils. Various aspects of the fluorescence behaviour of mineral oils such as intensity, wavelength distribution, and lifetime have been correlated with petroleum chemical composition and density. Fluorescence is often used to detect the presence of crude oil during drilling operations by observing the fluorescence of the cuttings. Total Scanning Fluorescence (TSF) technique has been used to discriminate drilling additives from crude oils, and to quantify the API gravity (density) of crude oils [8]. In some laboratory-based studies, absolute quantum yields [9, 1] and fluorescence emission spectra of various crude oils have been measured in the visible and the near infrared [9]. Results show the relative dependence of quenching rates on the excitation wavelengths and the chromophore interaction. Fluorescence emission spectra of oil pollution, phytoplankton and dissolved organic mater were registered using a shipboard laser spectrometer at 532 and 266 nm excitation wavelengths [11]. The Light Detecting And Ranging (LIDAR) technique has been recently used for monitoring oil spills on water surfaces based on the detection of the pollutant fluorescence response and oil characterization. The oil slick thickness is estimated using the suppression of the water Raman signal by an oil film. Laser spectroscopy of mineral oils on the water surface has been reported by Patsayeva et al. [12]. In this research, spectral properties of oil films with various thicknesses on the water surface are studied under controlled laboratory conditions. LIDAR systems operating at excitation wavelengths of 38 and 355 nm were used the measurement of the fluorescence lifetimes for different mineral oils. Field experiments with airborne fluorescent LIDAR FLS-A were performed to monitor water and land areas for oil transportation and storage. Techniques for real-time data acquisition and processing have been described based on a compiled and systematized library of Laser Induced fluorescence (LIF) spectra of various underlying surfaces [13]. Results confirm that such a system could be implemented in operational use for remote sensing of aquatic and terrestrial targets. The current work is a preliminary investigation of fluorescence behaviour of hydrocarbons using an LED-induced fluorescensor. The spectral distribution of the fluorescence emission such as spectral shape, maximum intensity and spectral width has been used to differentiate hydrocarbon oils. Two different quantitative techniques have been applied on collected fluorescence spectra to

Water Pollution VIII: Modelling, Monitoring and Management 257 detect crude and refined oils in the water environment. Theses techniques performed well and identified hydrocarbon oil slicks on water. Some of refined oils such as kerosene and petroleum spirit indicated no fluorescence response when they were excited by longer UV wavelengths (365-45 nm). While the rest of the oil samples showed a strong fluorescence emission between 4 nm and 55 nm, the selected excitation wavelength range chosen was not the optimum wavelength for fluorescence of all petroleum oils. More studies need to be performed using additional crude oil samples and shorter excitation wavelengths. 2 Experimental Four Australian crude oils (-1, -2, Juabert-1 and -1 and API gravity varying from 33 to 6 and some refined oils (kerosene, regular unleaded petrol, diesel, petroleum spirit and Shell 2W-5 engine oil from) were selected to fluorescence emission measurements. The crude oils selected originate from different locations across the Australia and represent different oil reservoir intervals. 1 Normalized intensity.5 Kerosene eume spirrit 3 35 4 45 5 55 6 65 7 Wavelength Figure 1: Fluorescence emission spectra of four Australian crude and five refined oils at 385 nm excitation wavelength. All oil samples, except kerosene and petroleum spirit, indicated a strong fluorescence emission between 4 nm and 55 nm when they were excited by UV wavelength (36-4 nm). Figure 1 shows the fluorescence emission spectra of all oil samples excited by 385 nm radiation. All fluorescence spectra were normalized to unit maximum intensity., petrol and engine oil indicated different shapes of their fluorescence spectra that were composed of 3 bands: one low intensity doublet at 42 nm and 44 nm, and one at 49 nm. All crude oils

258 Water Pollution VIII: Modelling, Monitoring and Management exhibited reasonable fluorescence response around 56 nm at the 528 nm excitation wavelength, while no fluorescence emission was observed for refined oils at this excitation wavelength (figure 2). The only response was the scattered radiation of the excitation source at 528 nm. A portable LED-induced fluorosensor has been designed to measure fluorescence emission spectra in both the field and laboratory. This fluorosensor system is built around a bundle of monochromatic excitation sources (365 nm to 78 nm) and a miniature optical bench. Each excitation source contains a multi- LED array. Each multi-led module is composed of multiple 5-mm diameter ultra bright LEDs (manufactured by ROITHNER LASERTECHNIK GmbH) closely packed into a compact 2-cm diameter aluminium head to achieve a uniform and smooth coverage of illumination. Each excitation source is powered by 4.5V DC battery. The long operating time of excitation sources make them suitable for any field operation. 1 Normalized intensity.5 eum spirit Kerosene 4 45 5 55 6 65 7 75 Wavelength Figure 2: Fluorescence emission spectra of four Australian crude and five refined oils at 528 nm excitation wavelength. Fluorescence data from oil samples are recorded over the ultraviolet to shortwave infrared wavelength range using an USB2-series Spectrometer (Ocean Optics). This miniature fiber optic spectrometer is a high-performance 248- element linear silicon CCD-array detector with sensitivity of 75 photons/count at 4 nm; 41 photons/count at 6 nm. The spectrometer accepts light energy transmitted through a single-strand optical fiber (SMA 95 to.22 numerical apertures) and disperses it via a fixed grating across the linear CCD array detector, which is responsive from 2-11 nm. Data transfer speed to memory for full scans is 13 ms with signal-to-noise ratio of 25:1 (at full signal). The

Water Pollution VIII: Modelling, Monitoring and Management 259 spectrometer unit is controlled by proprietary OOIBase32 software and the user may perform spectroscopic measurements such as absorbance, reflectance and emission; control all system parameters; collect data from up to 8 spectrometer channels simultaneously and display the results in a single spectral window; and perform reference monitoring and time-acquisition experiments. In the operational mode the software continually acquires data from the spectrometer. An integration time needs to be set and this affects the collected intensity. In order to be able to easily compare spectra they should be taken at the same integration time [14]. The system is capable of real-time measurements, on-the-spot analysis of released pollutants such as hydrocarbons and eliminates costly sample preparation and analytical procedures. In addition, the USB cable connects the spectrometer to the computer. Accordingly, no additional external power supply is required. 3 Results and discussion Oil samples were poured onto a water surface housed in a black-coated container. LEDs and fiber optics were placed approximately five cm away from the samples. The exciting light beam was incident the oil slick surface from above and the LED-induced fluorescence signals were collected through a fiber optic cable. A wide range of excitation wavelengths in the UV (365 to 395 nm), visible (45 nm to 7 nm) and near Infrared (78 nm) have been used. The fluorescence emission was recorded by time integrating 1 scans for each sample. Replicate values were averaged. The excitation source configuration for illumination of the samples is an important consideration. The BRDF of oil surface is strongly affected by the excitation source angle of incidence and the view direction (fiber optic detection angle) geometry. A smooth surface of oil films show the highest possible reflectance at the specular angle and the spectrometer can be saturated for this geometry. Quotient measurements were made using ratio recording of two fluorescence emission wavelengths. The method first involved an investigation to select key wavelengths in the UV-Visible-Near Infrared spectral interval. Three dominant wavelengths (42, 49, and 575 nm) were identified. Most of the hydrocarbon oils were classified with the blue-yellow quotient (I B-Y =I 42 /I 575 ) and the greenyellow quotient (I G-Y =I 49 /I 575 ), where I is the measured fluorescence relative intensity. The blue-yellow quotient and the green-yellow quotient for various crude and refined oils at the 375 nm, 385 nm, 395 nm and 45 nm excitation wavelengths are shown in figure 3. In all cases, values were significantly lower for crude oils than for refined oils for the green-yellow quotient. The same behaviour was observed for the blue-yellow quotient; however, there was some variability in the quotient value of refined oils. This method appears to be sensitive to differentiate crude oils from refined oils in the field environment.

26 Water Pollution VIII: Modelling, Monitoring and Management 1 Excited at 375 nm Excited at 385 nm Excited at 395 nm Excited at 45 nm The blue-yellow quotient 8 6 4 2 8 7 Excited at 375 nm Excited at 385 nm Excited at 395 nm Excited at 45 nm 6 The green-yellow quotient 5 4 3 2 1 Figure 3: The blue-yellow quotient and the green-yellow quotient of various hydrocarbon oils at the 375 nm, 385 nm, 395 nm and 45 nm excitation wavelengths. In some cases, it could be difficult to differentiate between various petroleum oils using fluorescence spectra alone or visual inspection when using a single excitation source, since some hydrocarbons have similar fluorescence spectral shapes. However, it is possible to differentiate between oils when the fluorescence intensity is reasonably higher than others. In a similar manner, a technique such as the dual-wavelength excitation fluorescence ratio may be used

Water Pollution VIII: Modelling, Monitoring and Management 261 to differentiate between crude and refined oils. The fluorescence emission spectra at 45 nm excitation wavelength divided by the fluorescence emission spectra at 528 nm excitation wavelength was termed the dual-wavelength excitation fluorescence ratio. The steady state fluorescence ratio of dualwavelength excitation versus wavelength, at similar temperatures and film thicknesses, are shown in figure 4 for various crude and refined oils. According to figure 4, the ratio increase with rising density of hydrocarbons. and two heavy crude oils, and, indicate the highest ratio, while petrol, diesel and kerosene show the lowest ratio, respectively. 8 6 Spectral ratio 4 2 45 5 55 6 65 Figure 4: 4 Conclusion Wavelength Ratio of the fluorescence emission spectra at 528 nm and 45 nm excitation wavelength for various hydrocarbon oils. The thin fluorescence spectrum of four Australian crude oils and some refined oils were examined using in-situ LED-induced fluorescence analysis using wide range of excitation wavelengths from the UV to the near infrared. The spectral distribution of the fluorescence emission, which contains obvious diagnostic potential, has been used as a quantitative technique to differentiate oil products. The objective of this research is to validate quantitative techniques to detect crude and refined oils in the marine environment. The blue-yellow (I B-Y =I 42 /I 575 ) and the green-yellow (I G-Y =I 49 /I 575 ) quotient have been developed and applied as fluorescence-based method to identify crude from refined oils. In addition, the dual-wavelength excitation fluorescence ratio can differentiate between crude and refined oils. Although these techniques performed reasonably well in the laboratory environment, they need to be validated in field condition using additional crude oil samples and excitation wavelengths.

262 Water Pollution VIII: Modelling, Monitoring and Management Acknowledgement The contribution of crude oil supplies to the project by Woodside and Geotechnical Services PTY LTD, Western Australia is gratefully acknowledged. References [1] Baker, A., Inverarity, R., Charlton, M.E. and Richmond, S., Detecting river pollution using fluorescence spectrophotometry: case studies from the Ouseburn, NE England. Environmental Pollution, 124, 57-7 23. [2] Reynolds, D.M. and Ahmad, S.R., Rapid and direct determination of wastewater BOD values using a fluorescence technique, Water Research 31, pp. 212 218, 1997. [3] Hoge F.E., Swift R. N., Airborne detection of ocean turbidity cell structure using depth-resolved laser induced water Raman backscatter, Applied Optics, 22: [4] Dolenko T. A., Fadeev V. V., Gerdova I. V., Dolenko S. A., Reuter R., Fluorescence diagnostics of oil pollution in coastal marine waters using artificial neural networks, Applied Optics, 41, 5155-5166, 22. [5] Dudelzak A.E., Babichenko S.M., Poryvkina L.V., Saar K. U., Total luminescent spectroscopy for remote laser diagnostics of natural water conditions, Applied Optics, v. 3, No. 4, 453-458,1991. 3778-3786, 1983. [6] Kaitala S., Babichenko S., Poryvkina L., and Leeben A., Fluorescent Analysis of Pigment Composition of Natural Phytoplankton, Marine Technology Society Journal, 28: 5 58, 1994. [7] Poryvkina, L.V., Babichenko, S.M. and Lapimaa, J.J., Spectral variability of humus substance in marine ecosystems, Ambio, 21:465-467, 1992. [8] Fder A.G., Iwanski P. and Montanari L., Light Emissions from Oil: A valuable Information source for petroleum analysis, TPoint, #2, pp.9-14, 24. [9] Downare, Taggart D., Mullins, Oliver C., Visible and Near-Infrared Fluorescence of Crude Oils, Applied Spectroscopy, Volume 49, Number 6, pp. 754-764(11), 1995. [1] Ralston, Corie Y., Wu, Xu, Mullins, Oliver C., Quantum Yields of Crude Oils, Applied Spectroscopy, Volume 5, Number 12, pp. 1563-1568(6), 1996. [11] Chubarov V. V. and Fadeev V. V., Ecological monitoring in the Caspian Sea (mouth zone of the river Volga) with a shipboard laser spectrometer, EARSeL eproceedings 3, 24. [12] Patsayeva S., Yuzhakov1 V., Varlamov V., Barbini R., Fantoni R., Frassanito C. and Palucci A., Laser spectroscopy of mineral oils on the water surface, Proceedings of EARSeL-SIG-Workshop, 2. [13] Babichenko S., Dudelzak A. and Poryvkina L., Laser remote sensing of coastal and terrestrial. Pollution by fls-lidar, EARSeL eproceedings 3, 24. [14] Ocean optics, OOIBase32 spectrometer operating software manual. 2.