Attune TM Acoustic Focusing Cytometer Training. Manik Punj Attune Training

Similar documents
determine optimum instrument settings for their own instruments and establish their own daily values.

Boundary-breaking acoustic focusing cytometry

NovoCyte Flow Cytometer

Application Note. Yeast Analysis with a life - dead staining kit (Yeast control - viability)

BD FACSCanto II. A proven research platform for maximum reliability and the highest quality results

flow cytometry reinvented

Flow Cytometry - The Essentials

CyFlow Cube series Appealing from every angle

CyFlow Space. Your Flexible Flow Cytometer.

CyFlow Space Your flexible flow cytometer

CyFlow Space Your flexible flow cytometer

Application Note. Assay Portability on the BD FACSVerse System. Summary. Maria Jaimes, Yibing Wang, Catherine McIntyre, and Dev Mittar

Your Research, Revolutionized

Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement

Flow Cytometry. Flow Cytometry Basics Guide

Detecting human circulating endothelial cells using the Attune Acoustic Focusing Cytometer

BD LSR Cell Analyzer. Performance without peer, choice without compromise

Your Research, Revolutionized

arc lamp is substituted. Before

Flow Cytometry Support Reagents

Direct visualization, sizing and concentration measurement of fluorescently labeled nanoparticles using NTA

Flow Cytometry. Cell Sorting 34 Instruments 34 Consumables 38

FLOW CYTOMETRY. CyAn ADP. Analyzer

Quantum Dot applications in Fluorescence Imaging for Calibration and Molecular Imaging

LIFluor EnhanCE. for use with dsdna 1000 and dsdna 20,000 Kits

Flow Cytometry. Flow Cytometry Basics Guide

SYTOX Green Dead Cell Stain

Qdot nanocrystal. wide range of biological investigations, Qdot nanocrystals are powerful complements

Flow Cytometry for Ploidy and Genome Size analysis - 1. Functional principles

Quality Control in Flow. Dr David Westerman Head of Haematopathology Peter MacCallum Cancer Centre

Visualization of digital data Interpretation of the visual

PERFECT-COUNT MICROSPHERES

Procarta Cytokine Assay Kit

EdU Flow Cytometry Kit. User Manual

Bioinstrumentation Light Sources Lasers or LEDs?

2. SUMMARY AND EXPLANATION

18/08/2011. Principles of Flow Cytometry (Practised in a Clinical Laboratory) Cytometer Components. Noel Williams Immunobiology Division of Immunology

Flow Cytometry. Marta Argenti, PhD student. Department of Biomedical Sciences Padua

Agilent AdvanceBio SEC Columns for Aggregate Analysis: Instrument Compatibility

Determining fluorescence Limit of Detection with Nanoparticle Tracking Analysis (NTA)

No-wash, no-lyse detection of phagocytic cells via a phrodo BioParticles functional assay in human whole blood on the

FACSCalibur. FACS200 Handbook Pro DNA. FACSCalibur FACSCalibur. FACS Calibur. FSC Diode 488 nm SSC PMT 488 nm. FACS200 Handbook Pro 1

ExoGlow -NTA Fluorescent Labeling Kit

Highly Accurate, Reliable and Real-time Enumeration of Individual Bacteria for the Determination of Raw milk Hygienic Quality

Featuring Analyst software under Windows NT for enhanced performance and ease of use. API 150EX. LC/MS System

Attune NxT Flow Cytometer. Efficient. Flexible. Transformative. Flow cytometry instrument

a Beckman Coulter Life Sciences: White Paper

Protocol for FACS analysis of HeLa cell transfectants

DEPArray Technology. Sorting and Recovery of Rare Cells

Guava easycyte Systems Expanding the potential of flow cytometry

CyAn ADP User Guide. September Document Number Revision B

Time-resolved Measurements Using the Agilent Cary Eclipse Fluorescence Spectrophotometer A Versatile Instrument for Accurate Measurements

Azure Biosystems Western Blotting Workflow

Calcein AM Cell Viability Kit

Electrophoresis and the Agilent Bioanalyzer. Advanced Biotechnology Lab I Florida Atlantic University January 23, 2008

Nuclear Condensation Assay Kit Green Fluorescence

Biofluids Analysis: Human Serum with High Throughput NMR

Maximizing the Performance of Capillary Electrophoresis Systems The Maximizing Data Quality Series Part 4

Flow Cytometry SOP: 14 color flow for immune activation, senescence, and exhaustion

Optimization of cief to Resolve Challenging MAb Samples of Clinical Immunodiagnostic Relevance

Test Your Plate Reader Set-up Before Using LanthaScreen Eu Assays

Intracellular ph (phi) Detection

Flow cytometry has become an increasingly important

Lower spectral overlap. Optimized stain index. Innovative antibodies. Superior multicolor flow cytometry. Violet Laser Reagents: The efluor Solution

Characterization of mab aggregation using a Cary 60 UV-Vis Spectrophotometer and the Agilent 1260 Infinity LC system

Phagocytosis Assay Kit (IgG FITC)

PCR SYSTEMS. a new era in high-productivity qpcr. Applied Biosystems ViiA 7 Real-Time PCR System

Spectral Separation of Multifluorescence Labels with the LSM 510 META

Calcium Assay Kit. Technical Data Sheet. Product Information. Description. Storage. Materials not included

ab Cell Viability Assay Kit Fluorometric Dual Green/Red

CASY Model TT E L E C T R I C A L C U R R E N T EXCLUSION ECE BASED CELL ANALYSIS

PowerPlex 5-Dye Matrix Standards, 3100/3130

Module 16: Gel filtration: Principle, Methodology & applications. Dr. Savita Yadav Professor Department of Biophysics AIIMS, New Delhi

High Throughput Quantitation of Cytokine Biomarkers using LANCE Ultra TR-FRET Assays

Using the Pulsed Flame Photometric Detector (PFPD) for Low-level Analysis of Organophosphorus Pesticides

a Beckman Coulter Life Sciences: White Paper

Deciphering Flow Cytometry Electronics

DNA Synthesis With IRDye 700 Phosphoramidite. Part #

EASY-Spray Columns. Guidance for column set up and installation Tips to maximize column lifetime

BD FACSCalibur. The flow cytometer for your routine cell analysis needs

BD Mouse Pluripotent Stem Cell Transcription Factor Analysis Kit

TECHNICAL NOTE THE NEXT GENERATION OF MICROPLATES

Multiplex Assay Design

Human Myostatin, ELISA Kit (MSTN)

ab Cellular ROS/Superoxide Detection Assay Kit

True Walkaway Automated Urinalysis, Chemistry to Microscopy The CLINITEK AUWi System Answers for life.

PowerPlex 4C Matrix Standard

BioPlex 2200 System. Like no other. The first and only fully-automated, random access, multiplex testing platform. Bio-Rad Laboratories

Simultaneous multi-color, multiphoton fluorophore excitation using dual-color fiber lasers

Method Development and Validation for Online UV-Dissolution Methods Using Fiber-Optic Technology

Fusion Analytical Method Validation

Identification of red and white blood cells from whole blood samples using the Agilent 2100 bioanalyzer. Application Note

Chem 321 Lecture 23 - Liquid Chromatography 11/19/13

EarlyTox Cell Integrity Kit

Picosecond Transient Absorption Spectroscopy System. picotas

MagniSort Mouse CD3 Positive Selection Kit Catalog Number: RUO: For Research Use Only. Not for use in diagnostic procedures.

MagniSort Mouse Hematopoietic Lineage Depletion Kit Catalog Number: RUO: For Research Use Only. Not for use in diagnostic procedures.

BD Accuri C6 Flow Cytometer Overview. Continuous Measurement of Intracellular Calcium and Other Cellular Responses

Lifetime stability of size exclusion chromatography columns for protein aggregate analysis

ab TGF beta 1 Human ELISA Kit

Transcription:

Attune TM Acoustic Focusing Cytometer Training Manik Punj Attune Training

Attune Training Agenda Section 1 An Introduction to Flow Cytometry Section 2 An Introduction to Acoustic Focusing Hydrodynamic Focusing vs. Acoustic Focusing Section 3 Instrument Systems Optics, Fluidics, Electronics Break Section 4 Performance Tracking Section 5 Software Overview Ribbons and Menus 2 Life Technologies Proprietary & Confidential 6/17/2011

What is Flow Cytometry? CYTOMETRY is the measurement of physical or chemical characteristics of cells or particles FLOW CYTOMETRY measurements are made as cells or particles in suspension pass individually through a flow cytometer instrument Performed on single cell suspensions Provides discrete measurements from each cell in the sample Provides a distribution of the measured characteristics in the sample 3 Life Technologies Proprietary & Confidential 6/17/2011

Flow Cytometry: What Can I do? Flow cytometric measurement records data from single cells Rapid statistical analysis on large numbers of cells are obtained Identifying subpopulations within a heterogeneous population Ability to identify cell populations on multiple characteristics Ideally suited for blood and other cells in suspension Ability to archive data Data format allows post acquisition analysis 4 Life Technologies Proprietary & Confidential 6/17/2011

Flow Cytometry Basics 1. Cells in a single profile pass through the flow cell 2. Laser hits individual cell Passing through the narrow tube called flow cell. 3. Deflected light hits a series of detectors (PMTs) 4. The signal from detectors are interpreted by a computer 5 Life Technologies Proprietary & Confidential 6/17/2011 Flow cell figure taken from http://www.med.umich.edu/flowcytometry/training/lessons/lesson1/index.htm

Particle Delivery: Hydrodynamic Focusing Hydrodynamic core Laser Cross Sectional Area narrow particle focus = narrow distribution sheath Count sheath Intensity 6 Life Technologies Proprietary & Confidential 6/17/2011

Particle Delivery: Hydrodynamic Focusing Low Flow Rate High Flow Rate Laser Cross Sectional Area sheath sheath sheath sheath 7 Life Technologies Proprietary & Confidential 6/17/2011

Particle Delivery: Hydrodynamic Focusing broad particle focus = broad distribution Count Laser Cross Sectional Area Intensity Increase sample input volume = increase flow rate = decrease in pressure difference = increase core diameter Particle distributions broadened Instrument resolution decreased Volumetric sample rates = 25 ul/min 150 ul/min 8 Life Technologies Proprietary & Confidential 6/17/2011 sheath sheath

Acoustic Focusing: How does Attune Cytometer Differ from Conventional Flow Cytometers? 9 Life Technologies Proprietary & Confidential 6/17/2011

What is Acoustic Focusing? A century old phenomenon No acoustic force With acoustic force 10 Life Technologies Proprietary & Confidential 6/17/2011

Acoustic Focusing Low Flow Rate High Flow Rate Laser Cross Section Acoustically focused Piezoelectric Transducer sheath sheath sheath sheath 11 Life Technologies Proprietary & Confidential 6/17/2011

Acoustic Focusing Cytometry: Practical Considerations Capillary Cells Piezoelectric ultrasonic device Acoustic forces cause cells to line up in the center of the capillary. No sheath flow is necessary for particle alignment. Flow rate past laser can be precisely controlled to very slow rates, allowing more fluorescence and scatter signal per particle (better sensitivity) Faster sample flow rates and speedy analysis of dilute samples facilitates rare event analysis Laser (~10µm high) Detector 12 Life Technologies Proprietary & Confidential 6/17/2011

13 Life Technologies Proprietary & Confidential 6/17/2011 Acoustic Focusing

Acoustically Focused Sample narrow particle focus = narrow distribution Count Acoustic focusing Intensity sheath sheath Laser Cross Section 14 Life Technologies Proprietary & Confidential 6/17/2011

Focus Cells Long Before They Get There Variable Laser Interrogation Times Laser Interrogation Point Laser Interrogation Point Variable flow speeds High Sensitivity Transit Time = 40 usec Total Volume = 600ul/min Velocity = ~0.5m/s High sensitivity mode/high sample rate 15 Life Technologies Proprietary & Confidential 6/17/2011 Standard Sensitivity Transit Time = 10 usec Total Volume = 2400 ul/min Velocity =~2m/s Standard Low sensitivity mode/high sample rate mode

Controlling Cell Speed Without Hydrodynamic Focus High sensitivity Standard sensitivity 100 ul/min 100 ul/min 0.5 meters/sec 2 meters/sec Laser Detector Focusing Solution Manifold Piezoelectric ultrasonic device Cells 16 Life Technologies Proprietary & Confidential 6/17/2011

Transit Modes and Times Standard (2400 ul/min total volume) Pre-set Sample Input Rate (in ul/min)* Focusing Fluid Input Rate (in ul/min) Focusing Fluid to Sample Ratio 25 2375 95:1 100 2300 23:1 200 2200 11:1 500 1900 3.8:1 1000 1400 1.4:1 *note that the particle velocity and interrogation time remains constant regardless of the sample input rate since the total volume (sample and focusing fluid) is constant at this transit mode High Sensitivity (600 ul/min total volume) Pre-set Sample Input Rate (in ul/min) 17 Life Technologies Proprietary & Confidential 6/17/2011 Focusing Fluid Input Rate (in ul/min) Focusing Fluid to Sample Ratio 25 575 23:1 100 500 5:1

18 Life Technologies Proprietary & Confidential 6/17/2011 Questions?

Section 2 - Instrument Systems Flow Cytometer is comprised of 3 subsystems: Fluidics - To introduce and focus the cells for interrogation Optics - To generate and collect the light signals Electronics - To convert the optical signals to proportional electronic signals for computer analysis 19 Life Technologies Proprietary & Confidential 6/17/2011

Fluidics The purpose of a fluidics system is to transport particles in a fluid stream to the laser beam for interrogation. Three conditions needed for optimal interrogation: The stream transporting the particles should pass through the focal point of the laser beam. Optimally one particle should move through the laser beam at one time. Fluidics system needs to be free of air bubbles & debris. 20 Life Technologies Proprietary & Confidential 6/17/2011

21 Life Technologies Proprietary & Confidential 6/17/2011 Fluidics

22 Life Technologies Proprietary & Confidential 6/17/2011

Fluids Attune Focusing Fluid is an isotonic, buffered, azide-free support/carrier reagent for transporting particles through the capillary assembly to the flow cell for laser interrogation. It contains a preservative and detergent designed to minimize bubble formation. Prevents sample from coming into contact with the walls of the flow cell (optical cuvette). Attune Wash Solution is a ready-to-use solution for removing cellular debris and dyes from the fluidics system of the instrument. Attune Shutdown Solution is a 10X solution that prevents bubble formation in the fluidics system of the instrument. Prepare a 1:10 dilution of the shutdown solution in deionized water. 10% Household Bleach Solution in deionized water (0.5% Sodium hypochlorite) decontaminates the fluidics lines. Prepare this solution fresh daily and use during the shutdown procedure. Deionized water used for diluting Attune Shutdown Solution and bleach, as well as for long-term storage of the instrument. 23 Life Technologies Proprietary & Confidential 6/17/2011

De-bubble is a user-initiated function for clearing bubbles in the fluidics lines of the cytometer. Fluidics Functions Wash is a user-initiated system cleaning between sticky samples. This function requires user supplied 10% bleach solution. Unclog function is a user-initiated back flush operation to remove clogs from the sample probe and flow cell. Rinse flushes system between samples to minimize carryover. This function is run automatically between samples, but it can also be user initiated. Shutdown is an automated function that decontaminates, cleans, rinses and powers off the cytometer. This mode requires user supplied bleach, Attune Wash Solution, and Attune Shutdown Fluid. Startup primes the instrument fluidics with Attune Focusing Fluid. Stop is used to end any running script. Clear Error is used to erase any error prompts. 24 Life Technologies Proprietary & Confidential 6/17/2011

25 Life Technologies Proprietary & Confidential 6/17/2011

Routine Maintenance Procedure Shutdown Visual inspection of sample injection port Visual inspection of fluidics tanks and connections Visual inspection of syringe pumps Computer maintenance Optical filter cleaning Fluidics maintenance Replacing syringes Changing focusing fluid filter Frequency Daily Daily Daily Daily Weekly Monthly As needed* As needed* As needed* * The frequency of maintenance depends on how often you run the cytometer. If the Attune is to be unused for a period of time exceeding two weeks, perform the shutdown function using distilled water. 26 Life Technologies Proprietary & Confidential 6/17/2011

Regular Computer Maintenance Procedures Back up your experiments on a regular basis to a secondary storage device Defragment the hard drive of the computer weekly Minimize memory usage: -When planning the experiments remember to delete parameters that you do not need i.e. only collect the parameters needed 27 Life Technologies Proprietary & Confidential 6/17/2011

28 Life Technologies Proprietary & Confidential 6/17/2011 Questions?

Optics Dichroic Mirrors Band Pass Filters 50mW 405nm Violet Laser 20mW 488 Blue Laser 29 Life Technologies Proprietary & Confidential 6/17/2011

Laser Light Scatter Forward Scattered light (FS) is proportional to cell-surface area or size. Side-scattered light (SS) is proportional to cell granularity/internal complexity of the cell. SS is usually collected at 90 degrees to the laser beam. Laser.......... FS detector SS detector 30 Life Technologies Proprietary & Confidential 6/17/2011

Fluorescence- Common Definitions Fluorescence - is the result of a three stage process in certain molecules called fluorophores, or fluorescent dyes. Absorption spectrum - The wavelength range over which a fluorescent compound can be excited. Emission spectrum - The range of emitted wavelengths of a fluorescent compound, it is a longer wavelength than the absorption wavelength. Auto-Fluorescence - Otherwise know as background fluorescence that originates from endogenous sample constituents or from unbound or nonspecifically bound probes. 31 Life Technologies Proprietary & Confidential 6/17/2011

This Box is to cover up the word summary and arrow 32 Life Technologies Proprietary & Confidential 6/17/2011

Blue (488 nm laser) BL1 BL2 BL3 Channel BL1 Possible Fluorochromes FITC, AF488, GFP, CSFE? 530/30 575/24 640LP BL2 PE, PI, YFP PE BL3 PerCP, PE Tandems, QDot 705 & 800 Blue (488nm) Laser Violet (405nm) Laser Flow Cell Channel Violet (405 nm laser) Possible Fluorochromes SSC Side scatter 405/20 450/40 522/30 603/48 VL1 VL2 Pac Blue, DyeCycle Violet, AF405 Fixable Aqua, QDot 525 VL1 VL2 VL3 VL3 Pacific Orange, Qdot 605 33 Life Technologies Proprietary & Confidential 6/17/2011

Optical Filters There are five types of optical filters used in flow cytometry: Bandpass filter (BP) Longpass filter (LP) Shortpass filter (SP) Dichroic mirror (DM) Neutral density filter (ND) 34 Life Technologies Proprietary & Confidential 6/17/2011

Band Pass Filters Long Pass Short Pass Dichroic Mirror 35 Life Technologies Proprietary & Confidential 6/17/2011

Compensation Compensation is the process by which we correct for "spillover Every fluorescent molecule emits light with a particular spectrum unique to that molecule These emission spectra overlap, in some cases very significantly 530/30 46.8% FITC 0.4% R-PE 0% PerCP 575/26 10.1% FITC 53.9% R-PE 0% PerCP 648 LP 0.1% FITC 8.8% R-PE 99.7% PerCP 36 Life Technologies Proprietary & Confidential 6/17/2011

37 Life Technologies Proprietary & Confidential 6/17/2011 Questions?

Electronics Functions of Electronics: Converts detected light signals into electronic signals Electronic signals are process by the computer system Converts signals from detectors into digital data used for analysis Electronics and Computers 38 Life Technologies Proprietary & Confidential 6/17/2011

Sample Flow Voltage Pulse in PMT Laser Voltage Time Laser Voltage Time Laser Voltage Peak Height Width Area Time 39 Life Technologies Proprietary & Confidential 6/17/2011

Electronic Pulse Volts Pulse Height Pulse Area 0 Pulse Width Time (µ Seconds) 40 Life Technologies Proprietary & Confidential 6/17/2011

Doublet Discrimination Doublets Singlets 41 Life Technologies Proprietary & Confidential 6/17/2011

42 Life Technologies Proprietary & Confidential 6/17/2011 Questions?

Instrument Performance Tracking Allows you to monitor performance of the instrument Critical to ensure accuracy and sensitivity of instrument Includes: Running the same bead particle set (Attune TM Performance Beads) Monitoring changes in the CV Monitoring changes in mean fluorescent intensity Tracking linearity of instrument Evaluating quantum efficiency and background Sets laser delay Sets the instrument s performance baseline Provides information about all the lasers and detection channels 43 Life Technologies Proprietary & Confidential 6/17/2011

Attune Performance Tracking Beads A mixture of beads of four fluorescence emission intensities in equal concentration Blank Dim Medium Bright 3mL vial PN: 4449754 44 Life Technologies Proprietary & Confidential 6/17/2011

Running Baseline Uses performance tracking beads CSV file obtained from Applied Biosystems website Performed any time a new lot of Attune TM Performance beads are used Performed after any major maintenance on the instrument The percent half-peak coefficient of variation (%HPCV) of the brightest bead is recorded PMT is adjusted to place the brightest bead at target MFI values, and voltage values for each channel are recorded Relative quantum efficiency (rq) and relative Background (rb) is calculated for each channel Linear regression is calculated and recorded Laser delay setting is also automatically calculated 45 Life Technologies Proprietary & Confidential 6/17/2011

46 Life Technologies Proprietary & Confidential 6/17/2011

Running Daily Performance Check Performed after baseline values have been defined Attune TM Performance Beads are used to run daily performance measurements to track the performance of the cytometer Run the performance test at least once per day that the instrument is used Determines the voltage required to place the brightest bead in the target MFI, and calculates the delta PMT voltages as compared to the baseline. %HPCV of the bright bead is recorded Relative quantum efficiency (rq) and relative Background (rb) is calculated for each channel Linear regression is calculated and recorded Laser delay setting is also automatically calculated Levy-Jennings charts provides a record of %HPCV and PMT voltage to check for shifts and trends 47 Life Technologies Proprietary & Confidential 6/17/2011

Daily Performance Check 48 Life Technologies Proprietary & Confidential 6/17/2011

Levey-Jennings Reports 49 Life Technologies Proprietary & Confidential 6/17/2011

PMT Voltage A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL). 50 Life Technologies Proprietary & Confidential 6/17/2011

Software Overview Main Features: Tracking and Performance Experiment Explorer Collection Panel Ribbons Menus 51 Life Technologies Proprietary & Confidential 6/17/2011

For Research Use Only. Not intended for any animal or human therapeutic or diagnostic use. 2010 Life Technologies Corporation. All rights reserved. The trademarks mentioned herein are the property of Life Technologies Corporation or their respective owners. NOTICE TO PURCHASER: Limited Use Label License The products shown in this presentation may be covered by one or more Limited Use Label License(s). Please refer to the respective product documentation or the Applied Biosystems website under www.appliedbiosystems.com for the comprehensive license information. By use of these products, the purchaser accepts the terms and conditions of all applicable Limited Use Label Licenses. These products are sold for research use only, and are not intended for human or animal diagnostic or therapeutic uses unless otherwise specifically indicated in the applicable product documentation or the respective Limited Use Label License(s). 52 Life Technologies Proprietary & Confidential 6/17/2011