SOUTH AFRICAN NATIONAL STANDARD

Similar documents
SOUTH AFRICAN NATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD

STAIRWAYS, HANDRAILS, AND GUARDRAILS (RESIDENTIAL)

2003 International Residential Building Code

Introduction. Products conforming with a European Council Directive. CE marked construction products. Other regulations

PRESCRIPTIVE COMPLIANCE METHOD

FACT SHEET #2 DECK INFORMATION

AS Residential timber-framed construction Part 2: Non-Cyclonic Areas

Visual Interpretation Of The

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

APPLICATION NUMBER:, TAX MAP KEY: STREET ADDRESS:, PRPOJECT: APPLICANT:, PHONE NO: MAILING ADDRESS:, FAX NO:

Licensed Copy: Institute Of Technology Tallaght, Institute of Technology, Sat Dec 02 09:19:48 GMT+00: , Uncontrolled Copy, (c) BSI This British

Administrative Changes

VTU EDUSAT PROGRAMME Lecture Notes on Design of Stair cases

RESIDENTIAL CONSTRUCTION New Dwellings and Additions

SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC Permit Requirements

PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION

Kitchen furniture Co-ordinating sizes for kitchen furniture and

BUILDING CODE VARIANCE

CITY OF BRISTOL DECK CONSTRUCTION GUIDE ACCORDING TO THE 2012 IRC WITH THE 2016 CT AMMENDMENTS

Loss Prevention Standard

Fully framed glass panels

4188 East Andrew Johnson Highway Morristown, TN

Applying the Building Code During Design

AS Australian Standard STEEL LADDERS FOR SHIPS VERTICAL LADDERS. This is a free 5 page sample. Access the full version online.

PRESCRIPTIVE COMPLIANCE METHOD

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS CONSUMER AND INDUSTRY SERVICES DIRECTOR S OFFICE BUREAU OF SAFETY AND REGULATION

Guarding to openable windows with low cill heights

EGRESS CHAPTER ,500 3 Over 2,500 4 OCCUPANT LOAD REQUIRED MEANS OF EGRESS

Accessibility for Ontarians with Disabilities Act (AODA), 2005

CITY OF FRUITLAND DIVISION OF PLAN REVIEW & PERMITTING DECK GUIDE. This design guide assumes all lumber to be pressure-treated Southern Pine.

NATIONAL BUILDING REGULATIONS AND BUILDING STANDARDS ACT, 1977 (Act No. 103 of 1977)

Metallic products Types of inspection documents

Building Guide. Colorado Chapter of the International Conference of Building Officials. Building Guide

The following are details of the code requirements of the 2015 International Residential Code for single-story decks.

RESIDENTIAL BUILDING PLAN REQUIREMENTS

CITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT. Submittal Requirements

Section 1 OBC FADS /13 Access to Parking Areas

PIP STF05520 Details for Pipe Railing for Walking and Working Surfaces

PIP STF05511 Fixed Industrial Stairs

ICC CODE CORNER 2012 IFC Code & Commentary

Workplaces must be kept clean, orderly, and sanitary. Workroom floors must be maintained as clean and dry as possible.

RESIDENTIAL BUILDING REQUIREMENTS

N1 to N3. DuraGalPlus Domestic Construction Manual. Volume 2: DuraGalPlus RHS as lintels (garage beams, window heads)

Tolerances for Concrete Construction. Tolerances for Concrete Construction. Tolerance 6/16/2015

Decks. SPS (1) SPS (2) AKA Appendix B & C

Specification and approval of welding procedures for metallic materials

STRUCTURAL CALCULATIONS

Timber in Bushfire Prone Areas

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST

UGRA LVL Laminated Veneer Lumber

Doors, Windows, Stairs & Fireplaces Doors Doors Outdoor Entry Outdoor Entry Doors Doors Outdoor Entry Outdoor Entry

2009 IBC Section 1024 Approved Luminous Egress Path Markings

Steps And Stairs Installation Option 1 - Steps In Wall Option 2 - Steps With Plant Space Option 3 - Steps In Front of Walls Option 4 - Steps Along

Carpenter Level 2 Rev. September 2017

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck)

Special Inspections for Wood Construction BCD710 Michelle Kam-Biron, PE, SE, SECB Senior Director, Education American Wood Council

BISON PRECAST FLOORING SPECIFICATION

WHO IS THIS COURSE FOR?

Excerpts from: International Residential Code 2009

Steps And Stairs Installation Steps In Wall - Option 1 Steps In Front of Walls - Option 2 Steps In Wall; 10 (25cm) Tread - Option 3 Step Parallel to

ISO INTERNATIONAL STANDARD

Plastics collapsible containers for human blood and blood components. Part 1: Conventional containers

DESIGN GUIDE 2. Common Timber Stairs. A Design Guide to Manufacturing Safe and Compliant Staircases. Introduction. British Woodworking Federation 2017

2012 IRC Sections R303 R310 Building Planning II

BUILDING PERMIT APPLICATION PACKAGE

2014 Florida Residential Code Advanced 5th Edition: Overview Internet

NZS :2008. Glazing in buildings NZS :2008. Part 4: Wind, dead, snow, and live actions. New Zealand Standard

Access Ladders And Disappearing Stairways: Code Compliant Solutions

Florida Accessibility Code for Building Construction

Code Requirements for Existing Buildings. R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617)

ENGINEERING STANDARD FOR INDUSTRIAL STAIRS, LADDERS, PLATFORMS AND SCAFFOLDS ORIGINAL EDITION JULY 1997

Australian/New Zealand Standard

AS/NZS :2003. Plumbing and drainage AS/NZS :2003. Australian/New Zealand Standard. Part 3: Stormwater drainage

BUILDING BULLETIN One and Two Family Dwellings Decks and Residential Access Ramps

SIDEWALK & RAILING REPLACEMENT BOARD OF ED BUILDING

CITY OF CALABASAS RESIDENTIAL PLAN REQUIREMENTS 1 OF 5 8/2017 PLAN INFORMATION

EN DK NA:2007

CODE COMPLIANCE PLAN REVIEW PROCEDURES

SPECIFICATION FOR Aluminium alloy windows

CHAPTER 26 PLASTIC SECTION BC 2601 SECTION BC 2603 GENERAL FOAM PLASTIC INSULATION

Bridge Strikes from Road Vehicles or Waterborne Vessels

ARCHITECTURAL GUIDE SPECIFICATIONS - DESCRIPTIVE

Australian Standard. Design and installation of sheet roof and wall cladding. Part 3: Plastic AS AS

This document is a preview generated by EVS

CHAPTER 9 STAIR CASES 9.1 GENERAL FEATURES 9.2 TYPES OF STAIR CASES

KENYA STANDARD KS 574:2017. Steel fabric for reinforcement of concrete Specification

SECTION SEISMIC RESTRAINT REQUIREMENTS FOR NON-STRUCTURAL COMPONENTS REVISED PART 1 GENERAL 1.1 DESCRIPTION:

Effective Date: 14-March Table of Contents

Fire Inspection and Code Enforcement, 7 th Edition. Chapter 6 Building Construction: Components Inspector II

RESIDENTIAL WOOD DECK CONSTRUCTION GUIDE

This document is a preview generated by EVS

PIP STF05521 Details for Angle Railings for Walking and Working Surfaces

Residential Decks 1 & 2 Family Dwellings and Townhouses City of Owatonna BUILDING DEPARTMENT

Trusted SECTION: 04 HILTI, INC. TULSA, Conformity! ICC-ES Evaluation. not specifically. Copyright 2015

Permit Requirements: Building Codes: The City of Clanton has adopted the following codes which are enforced by the Building Department:

Standards for Testing and Rating Shoring Equipment

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

The Building Codes A.R.E. Building Design and Construction Exam Prep

This document is a preview generated by EVS

Transcription:

ISBN 978-0-626-24057-8 SOUTH AFRICAN NATIONAL STANDARD The application of the National Building Regulations Part M: Stairways Published by SABS Standards Division 1 Dr Lategan Road Groenkloof Private Bag X191 Pretoria 0001 Tel: +27 12 428 7911 Fax: +27 12 344 1568 www.sabs.co.za SABS

Table of changes Change No. Date Scope Acknowledgement The SABS Standards Division wishes to acknowledge the work of the South African Institution of Civil Engineering in updating this document. Foreword This South African standard was approved by National Committee SABS TC 59, Construction standards, in accordance with procedures of the SABS Standards Division, in compliance with annex 3 of the WTO/TBT agreement. This document was published in April 2011. This document supersedes the corresponding parts of SABS 0400:1990 (first revision). Compliance with the requirements of this document will be deemed to be compliance with the requirements of part M of the National Building Regulations, issued in terms of the National Building Regulations and Building Standards Act, 1977 (Act No. 103 of 1977). SANS 10400 consists of the following parts, under the general title The application of the National Building Regulations: Part A: General principles and requirements. Part B: Structural design. Part C: Dimensions. Part D: Public safety. Part F: Site operations. Part G: Excavations. Part H: Foundations. Part J: Floors. Part K: Walls. Part L: Roofs. Part M: Stairways.

Foreword (concluded) Part N: Glazing. Part O: Lighting and ventilation. Part P: Drainage. Part Q: Non-water-borne means of sanitary disposal. Part R: Stormwater disposal. Part S: Facilities for persons with disabilities. Part T: Fire protection. Part V: Space heating. Part W: Fire installation. This document should be read in conjunction with SANS 10400-A. Annex A is for information only. 1

Contents Page Acknowledgement Foreword 1 Scope... 3 2 Normative references... 3 3 Definitions... 4 4 Requirements... 5 4.1 4.2 4.3 4.4 4.5 General... 5 Dimensional requirements... 6 Prevention against falling... 8 Masonry stairways... 8 Timber stairways... 10 Annex A (informative) National Building Regulations Part M: Stairways... 11 2

The application of the National Building Regulations Part M: Stairways 1 Scope This part of SANS 10400 provides deemed-to-satisfy requirements for compliance with part M (Stairways) of the National Building Regulations. NOTE Part M of the National Building Regulations, issued in terms of the National Building Regulations and Building Standards Act, 1977 (Act No. 103 of 1977), is reproduced in annex A. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. Information on currently valid national and international standards can be obtained from the SABS Standards Division. SANS 1460, Laminated timber (glulam). SANS 1783-2, Sawn softwood timber Part 2: Stress-graded structural timber and timber for frame wall construction. SANS 2001-CC1, Construction works Part CC1: Concrete works (structural). SANS 2001-CC2, Construction works Part CC2: Concrete works (minor works). SANS 2001-CM1, Construction works Part CM1: Masonry walling. SANS 10005, The preservative treatment of timber. SANS 10400-A, The application of the National Building Regulations Part A: General principles and requirements. SANS 10400-B (SABS 0400-B), The application of the National Building Regulations Part B: Structural design. SANS 10400-K, The application of the National Building Regulations Part K: Walls. SANS 10400-S, The application of the National Building Regulations Part S: Facilities for persons with disabilities. SANS 10400-T, The application of the National Building Regulations Part T: Fire protection. 3

3 Definitions For the purposes of this document, the definitions given in SANS 10400-A (some of which are repeated for convenience) and the following apply. 3.1 accredited testing laboratory laboratory that has been accredited by the South African National Accreditation System (SANAS) 3.2 deemed-to-satisfy requirement non-mandatory requirement, the compliance with which ensures compliance with a functional regulation 3.3 emergency route that part of an escape route which provides fire protection to the occupants of any building and which leads to an escape door 3.4 escape door door in an escape route which, at ground level, leads directly to a street or public place or to any approved open space which leads to a street or public place 3.5 escape route entire path of travel for all persons, including persons with disabilities, from the furthest point in any room in a building to the nearest escape door and may include an emergency route 3.6 flight that part of a stairway which consists of consecutive steps between landings 3.7 functional regulation regulation that sets out in qualitative terms what is required of a building or building element or building component in respect of a particular characteristic, without specifying the method of construction, dimensions or materials to be used 3.8 going distance (measured on plan) between the nosing of a tread and the nosing of the tread or landing immediately above it 3.9 landing platform between two consecutive flights of a stairway 3.10 nosing edge of a step projecting beyond the riser 3.11 person with disabilities person who has long-term physical, mental, intellectual or sensory impairments which, in interaction with various barriers, might hinder his full and effective participation in society on an equal basis with others 4

3.12 pitch line notional line which connects the nosings of all the treads in a flight of stairs 3.13 riser vertical distance between the tread of a step and the tread of the step immediately above it 3.14 spiral stairway succession of tapered treads forming a curved stairway which extends as a single flight from one floor or landing to another 3.15 stairway part of a building which provides a route of travel between different levels in such building and is formed by a single flight or by a combination of two or more flights and one or more intervening landings 3.16 tapered tread tread which has a greater width at one side than at the other and a going which changes at a constant rate throughout its length 3.17 tread upper surface of a step 3.18 winder tapered tread that has a going of at least 50 mm and which is used in conjunction with non-tapered treads in a single flight 4 Requirements 4.1 General 4.1.1 The functional regulations pertaining to stairways contained in part M of the National Building Regulations (see annex A) shall be deemed to be satisfied where a) the stairway, including any handrail to such stairway, is in accordance with the requirements of 4.2 and 4.3, b) the stairway complies with the requirements of 1) SANS 10400-B and SANS 10400-T, or 2) in the case of occupancies classified as H3 and H4 (see Regulation A20 in SANS 10400-A) in single-storey and double-storey buildings, 4.4 or 4.5, and c) any wall, screen, railing or balustrade to such stairway is in accordance with the requirements of either SANS 10400-B or SANS 10400-K and SANS 10400-T. 4.1.2 Specific requirements for stairways in buildings in which facilities for persons with disabilities are provided, shall be in accordance with SANS 10400-S. NOTE 1 SANS 10400-S reduces the rise of the step, increases the width of the stairway and the length of the landing, requires solid risers where stairs overlap the next lower tread, and requires handrails on both sides of the stairway. 5

NOTE 2 SANS 10400-T, in the case of emergency routes, increases the width of stairways, prohibits the use of spiral stairways, and requires solid risers on any occupancy class of building other than D4. 4.2 Dimensional requirements 4.2.1 The headroom at any point on any stairway shall be not less than 2,1 m, measured vertically from the pitch line, and the width of any stairway, measured to any enclosing wall or balustrade, shall be not less than 750 mm (see figure 1). Figure 1 Minimum permissible headroom on a stairway 4.2.2 Any landing serving two flights in the same straight line shall a) have a length of not less than 900 mm, and b) have a width of not less than that of such flights. 4.2.3 No flight of stairs shall have a vertical rise greater than 3 m between landings. 4.2.4 No door shall open onto a stairway unless such door opens onto a landing and the width of such landing is not less than that of such door. The position of the door relative to the landing and its direction of opening shall be such that it does not obstruct the flow of persons on the stairway when in the fully open position. 4.2.5 The rise of any step shall not exceed 200 mm. 4.2.6 The going and width of any tread shall be not less than 250 mm, provided that where the stairway does not have solid risers, each tread shall overlap the next lower tread by not less than 25 mm (see figure 2). Figure 2 Dimensions of treads and risers on a stairway 6

4.2.7 The variation in the dimensions of the risers and the goings of the treads in any one flight shall be not more than 6 mm, provided that this requirement shall not be construed as prohibiting the use of tapered treads in the same flight as non-tapered treads. 4.2.8 The dimension of each step of the stairway shall be such that the sum of the going and twice the riser is not less than 570 mm and not more than 650 mm. 4.2.9 Any tapered tread that is not a winder and that does not form part of a spiral stairway shall (see figure 3) a) be so designed that, in respect of that part of the tread which is 400 mm from the narrower end of such tread, the going 1) complies with the requirement of 4.2.6, or 2) equals, in the case of a flight containing both tapered and non-tapered treads, the going of the non-tapered treads, b) have a minimum going of 125 mm, c) be so constructed that the angle between successive risers, measured in the horizontal plane, is constant, and d) comply with the requirement of 4.2.7 for variation in goings, where such variation is, in each case, measured at the same distance from the narrower end of each tread. Dimensions in millimetres To check the variation in going between treads, measure each tread at the same distance from the narrower end. Figure 3 Measurement of tapered treads 4.2.10 Stairways incorporating winders shall be permitted only in dwelling houses and within individual dwelling units, and at any point on such stairway a) there shall be not more than three successive winders, and b) such winders shall not turn through more than 90 (see figure 4). 4.2.11 Any spiral stairway shall have a width of not more than 800 mm and such stairway shall not be used a) as part of any emergency route, b) in any occupancy classified in terms of Regulation A20 as A1, A2, A3, A4, A5, C1, E1, E2, E3, E4, F1, G1, H1, H2 or H5. 7

a) U-shaped stairway b) L-shaped stairway Figure 4 Examples of winders 4.3 Prevention against falling 4.3.1 Any flight of steps which contains more than three risers shall have protection on both sides provided by a secure wall, screen, railing or balustrade which shall be not less than 1 m high and so erected that any such wall, screen, railing or balustrade in any occupancy classified as E2, E3, E4, H1, H2, H3, H4 or H5 shall not have any opening above the pitch line that permits the passage of a 100 mm diameter ball; provided that such protection in any occupancy that is not an occupancy classified as E2, E3, E4, H1, H2, H3, H4 or H5 shall consist of at least a handrail and one other rail midway between such handrail and the stair tread. 4.3.2 Any flight of stairs which contains more than five risers shall be provided with at least one continuous handrail extending the full length of such flight, provided that this requirement shall not apply to any building classified as H4, or within individual dwelling units in an occupancy classified as H3. 4.3.3 The handrail to any flight of stairs provided in terms of 4.3.2 shall be a) on at least one side of the flight where the width of the flight is less than 1,1 m, and on both sides where the width exceeds 1,1 m, b) securely fixed to such wall, screen, railing or balustrade at a height of not less than 850 mm and not more than 1 m measured vertically from the pitch line to the upper surface of the handrail, and c) of such a design and so fixed that there shall be no obstructions on, above or near to it which might obstruct the movement of a hand moving along it. 4.4 Masonry stairways Masonry stairways and landings in occupancies classified as H3 and H4 in single-storey and double-storey buildings shall be in accordance with the provisions of figure 5 and the relevant requirements of SANS 2001-CM1 and SANS 2001-CC1 or SANS 2001-CC2. 8

Figure 5 Composite concrete lintel and masonry stairway construction details NOTE The number of steps will vary. 9

4.5 Timber stairways 4.5.1 Timber stringer beams to support timber treads in stairway construction that does not exceed 1,2 m in width in occupancies classified as H3 and H4 in single-storey and double-storey buildings, shall be of minimum size 48 mm 225 mm, of grade 5, comply with the requirements of SANS 1460 or SANS 1783-2, and be sufficiently free of warp in any direction to be fit for purpose. 4.5.2 Timber treads shall be a minimum of 36 mm thick. Timber treads may be built into masonry walls with a minimum end bearing of 90 mm, or be supported on a steel angle cleat that has minimum dimensions of 50 mm 50 mm 4 mm, and is bolted to a wall with two masonry anchors per cleat in accordance with the manufacturer s instructions. Such anchors, when embedded in grade 20 concrete, shall have a safe working load in shear of not less than 1,25 kn, certified by the manufacturer. Such certification shall be substantiated by test reports or certificates from recognized local or international accredited testing laboratories. 4.5.3 All timber (see subregulation A13(b)) used in timber stairways shall be preservative treated in accordance with SANS 10005, as relevant. 10

Annex A (informative) National Building Regulations Part M: Stairways M1 General Requirement Any stairway, including any wall, screen, railing or balustrade to such stairway, shall: (a) be capable of safely sustaining any actions which can reasonably be expected to occur and in such a manner that any local damage (including cracking) or deformation do not compromise its functioning; (b) permit safe movement of persons from floor to floor; and (c) have dimensions appropriate to its use. M2 Fire Requirement A stairway contemplated in regulation M1 shall comply with the relevant requirements in part T of these regulations. M3 Deemed-to-Satisfy Requirements The requirements of regulations M1 and M2 shall be deemed to be satisfied where the design of any stairway complies with SANS 10400-M. SABS 11

This page has been left blank intentionally

SABS Standards Division The objective of the SABS Standards Division is to develop, promote and maintain South African National Standards. This objective is incorporated in the Standards Act, 2008 (Act No. 8 of 2008). Amendments and Revisions South African National Standards are updated by amendment or revision. Users of South African National Standards should ensure that they possess the latest amendments or editions. The SABS continuously strives to improve the quality of its products and services and would therefore be grateful if anyone finding an inaccuracy or ambiguity while using this standard would inform the secretary of the technical committee responsible, the identity of which can be found in the foreword. Tel: +27 (0) 12 428 6666 Fax: +27 (0) 12 428 6928 The SABS offers an individual notification service, which ensures that subscribers automatically receive notification regarding amendments and revisions to South African National Standards. Tel: +27 (0) 12 428 6883 Fax: +27 (0) 12 428 6928 E-mail: sales@sabs.co.za Buying Standards Contact the Sales Office for South African and international standards, which are available in both electronic and hardcopy format. Tel: +27 (0) 12 428 6883 Fax: +27 (0) 12 428 6928 E-mail: sales@sabs.co.za South African National Standards are also available online from the SABS website http://www.sabs.co.za Information on Standards The Standards Information Centre provides a wide range of standards-related information on both national and international standards, and is the official WTO/TBT enquiry point for South Africa. The Centre also offers an individual updating service called INFOPLUS, which ensures that subscribers automatically receive notification regarding amendments to, and revisions of, international standards. Tel: +27 (0) 12 428 6666 Fax: +27 (0) 12 428 6928 E-mail: info@sabs.co.za Copyright The copyright in a South African National Standard or any other publication published by the SABS Standards Division vests in the SABS. Unless exemption has been granted, no extract may be reproduced, stored in a retrieval system or transmitted in any form or by any means without prior written permission from the SABS Standards Division. This does not preclude the free use, in the course of implementing the standard, of necessary details such as symbols, and size, type or grade designations. If these details are to be used for any purpose other than implementation, prior written permission must be obtained. Details and advice can be obtained from the Senior Manager. Tel: +27 (0) 12 428 6666 Fax: +27 (0) 12 428 6928 E-mail: info@sabs.co.za