Agilent 500 Ion Trap LC/MS with the Agilent 1200 Infinity Series

Similar documents
Agilent 6500 Series Q-TOF LC/MS System

Technical Overview. Author. Abstract. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Shipping Estimator User Guide

DCMS Link 2.10 for Compass / HyStar

CHAPTER 10 ACQUISITION AND PAYMENTS

How to Create a Basic SAP Business Workflow

Agilent 7820A GC System THE EASY CHOICE FOR ROUTINE ANALYSES

MANAGE WORKFLOWS JOB AID

INTRO TO WORK PLANNING IN MIRADI 4.4

OpenLAB CDS ChemStation Edition C Tips and Tricks for GC Users

Student Worker Contract Contract Submitter Instructions

Lanteria HR Performance - Competence

Audit Logging and Reporting

Remedy Change Management 4.0

Agilent University Course Catalog Edition Thailand

Controlling Agilent 1200 Series Rapid Resolution LC systems through Waters Empower chromatography data software. Technical Overview.

MANUAL MY.DHLPARCEL.NL

Self-Service Invoice Guide

THE UNIVERSITY O K L A H O M A

SharePoint Adoption Guide

About SMART Practice Aids - Field Work

IFMS STARTER KIT FOR SAP RE-FX

Sage 100 Direct Deposit. Getting Started Guide

HansaWorld Enterprise

Lanteria HR Core HR

Price Setup Wizard: How to Make Global Updates to the Pricebook

Task Reflection. User Guide

UT HEALTH CAREERS offers those responsible to recruit and approve recruiting the ability to:

Automated PAN Functions in UltiPro

CONVERSION GUIDE Trial Balance CS and Engagement CS to AdvanceFlow

Create a Non-Catalog Requisition

Training Lesson: Appointments, Set Appointments (Administrator Access Only) Revision:

New Look!!! Medical Record View Module

Contents OVERVIEW... 3 CONFIGURATION... 4

Lab 4: Using the Workflow Engine

Reference Guide for Managers: Halogen eappraisal

Agilent Food Profiling Solutions ASSESS FOOD QUALITY AND POINT OF ORIGIN

EPA Method 543: Selected Organic Contaminants by Online SPE LC/MS/MS Using the Agilent Flexible Cube

Fleet Compass Flagship Fleet Management, LLC. Shop & Inventory Management

Precise Characterization of Intact Monoclonal Antibodies by the Agilent 6545XT AdvanceBio LC/Q-TOF

Scheduling Interviews

BioConfirm B Presentation

Materials Control. POS Interface Materials Control <> MICROS Simphony 1.x. Product Version POS IFC Simph1.x Joerg Trommeschlaeger

ICP Expert software. Technical Overview. Introduction

Quick Start Guide. Taking A Payment & Printing A Receipt

Electronic Invoicing

Bulk payments made easy with ABA files

Procedure & Guide. B2B Booking Dealer. B2B Booking Dealer. Kimpex inc.

New Features in Primavera Portfolio Management 15.1

Campaign Management Implementation Guide

Sage 300 ERP Sage CRM 7.1 Integration Upgrade Guide

LEARNING RESOURCE CENTRE AYRSHIRE COLLEGE MICROSOFT WORD USEFUL ESSAY FEATURES

Confident Pesticides Analysis with the Agilent LC/Triple Quadrupole and TOF/QTOF Solutions

In this article, we are covering following broad sections on financial consolidation process:

Talent Management System User Guide. Employee Profile, Goal Management & Performance Management

Purchase Order, Requisitions, Inventory Hands On. Workshop: Purchase Order, Requisitions, Inventory Hands On

Workday: Frequently Asked Questions (FAQ)

GETTING STARTED WITH QUICKEN with Online Bill Pay 2010, 2009, and for Windows

myhr Oracle Human Capital Management

HR Business Partner Guide

Supervisor Training Packet

Supervisor Web Services Training Guide For. Aquinas College

ClubConnect Accounts Payable Understanding Invoice and Check Types for Easy Processing

Oracle Landed Cost Management

TECHNICAL NOTE THE NEXT GENERATION OF MICROPLATES

Tutorial #3: Brand Pricing Experiment

Contents OVERVIEW... 3

NetSuite OpenAir/NetSuite Connector Guide April

KU MIX 5.0 QUICK START GUIDE

Orientation Towards the Future Through Innovation

EmpowerTime Supervisor User Guide Table of Contents

Vanderbilt University

Crowe Project Management

ejobs Guide for Hiring Managers

Process Temporary Assignment Changes in WorkForce (That have not been filled by the posting process)

QUICK Guide. System start-up and shutdown 3. Operating panels. State colors. General process description. Device operating modes

BEFORE YOU BEGIN You will need to know the vendor, WBS Element, Fund, and Project Manager for the job.

ServicePRO + PartsPRO User Guide

UNITY CRM INTEGRATION AGILE CRM

Performing the CTA Carryover PVT Procedure on the LXi or DXC 600i System

Communication between SIMATIC WinCC Industrial Data Bridge and SIMATIC S7

Block Leading in Service Assistant

Skill FMEA Pro The world leader in FMEA software since 1995

STP351: Purchase Order Collaboration in SNC

EPAF. Electronic Personnel Action Forms What is EPAF? On-line form for student hourly and salary jobs

Ordering Online with youravon.com

ONBOARDING. 4 Ways icims Talent Platform Helps Build Best-Practices icims Inc. All Rights Reserved.

Sage MAS 90 and 200 Product Update 2 Delivers Added Value!

Enterprise etime. Getting Started Participant Guide V.6.1. ADP Time & Labor Management

Change Management. ServiceNow User Guide. Version 2.0 Novmeber, November 2015

Quick Start Guide Coles Product Catalogue

Vacation/Sick/Holiday Time in TimeSaver

Agilent VEE Pro 9.0 & Agilent VEE Express 9.0

Reference Guide for Employees: Halogen eappraisal

Creating a CMD in CDX

Managing Projects (Course Code: 5927A) Course length: 3 days

Headline 2. Zeile. D&B Connect The customized process platform for evaluating your business partners in SAP

CCM 1.1 Field Staff User Guide

go vertical. for Microsoft Dynamics AX About MBS Dev Professional Microsoft Dynamics AX Partner Wholesale Distribution Suite

Transcription:

Agilent 500 Ion Trap LC/MS with the Agilent 1200 Infinity Series Quick Start Guide Step 1. Set up and learn about the system 3 Step 2. Create method and Sequence Sample List 4 Step 3. Start the Sample List in MS Workstation and Sequence in ChemStation 5 Troubleshooting 10 Use this guide to learn how to set up the Agilent 1200 Infinity Series to automatically inject samples for analysis on Agilent 500 Ion Trap LC/MS and MS Workstation software. See Figure 1 for an overview of the workflow. Agilent Technologies

500 Ion Trap LC/MS: How to Acquire MS Data Workflow In MS Workstation check that 500-MS is NOT in the AutoStart Module box. Create MS acquisition method in MS Workstation. Create HPLC method in ChemStation. Create Sample List in MS Workstation. Create Sequence Table in ChemStation. Make sure runtimes in MS Workstation ti and ChemStation ti are synchronized. (Allow extra time in LC method for Post Run Events in MS Workstation method.) Make sure number of vials/injections are synchronized. Begin MS Workstation Sample List. Start Sequence in ChemStation. Injection and MS analysis of samples begins Figure 1 Workflow overview 2 Agilent 1200 Infinity Series LC to Agilent 500 Ion Trap LC/MS Set-Up Guide

Step 1. Set up and learn about the system Step 1. Set up and learn about the system Refer to the Agilent 1200 Infinity Series and ChemStation user guides, the Agilent 500 Ion Trap LC/MS operator manuals, and online Help to become familiar with the two systems. Refer to the Agilent 500 Ion Trap LC/MS with the Agilent 1200 Infinity Series Set-Up Guide for an overview of how the two systems are physically integrated. Open the MS Workstation Configuration Window and make sure that the 500-MS icon is not in the AutoStart Module box. See for Figure 2. Figure 2 MS Workstation Configuration Window with empty AutoStart Module box Agilent 1200 Infinity Series LC to Agilent 500 Ion Trap LC/MS Set-Up Guide 3

Step 2. Create method and Sequence Sample List Step 2. Create method and Sequence Sample List 1 Make sure the Sample List (MS Workstation) and the Sequence entries (ChemStation) are synchronized, including number of injections per vial. Refer to these documents: 500-MS LC/MS Quick Reference Guide and 500-MS Software Operation Manual for method development guidelines 500-MS Software Operation Manual for MS method and Sample List creation Agilent 1200 Infinity Series user guides and ChemStation online Help for LC method and Sequence creation 2 Make sure the LC program run time is equal to or longer than the MS program run time. The LC run time needs to account for the time taken by MS Workstation to do post-run processing actions (such as autolink or data processing). In general, when a post-run action has been selected, you can set the LC method post-run time in ChemStation to 2 minutes. When multiple post-run processing actions are done in MS Workstation, you may need to extend the LC method post-run time. Do a test run to measure the time taken from sample injection to the completion of the MS post-run processing actions. 4 Agilent 1200 Infinity Series LC to Agilent 500 Ion Trap LC/MS Set-Up Guide

Step 3. Start the Sample List in MS Workstation and Sequence in ChemStation Step 3. Start the Sample List in MS Workstation and Sequence in ChemStation 1 In MS Workstation, in the Sample List window, click Begin to start the Sample List in MS Workstation Figure 3 MS Workstation Begin button in Sample List window Agilent 1200 Infinity Series LC to Agilent 500 Ion Trap LC/MS Set-Up Guide 5

Step 3. Start the Sample List in MS Workstation and Sequence in ChemStation When the yellow Waiting indicator flashes, the LC/MS has achieved equilibration. The LC/MS is now waiting for sample injections. See Figure 4. Figure 4 MS Workstation System Control window with yellow flashing Waiting indicator 6 Agilent 1200 Infinity Series LC to Agilent 500 Ion Trap LC/MS Set-Up Guide

Step 3. Start the Sample List in MS Workstation and Sequence in ChemStation 2 In the ChemStation program, in the Instrument Control tab, click Start to start the Sequence. Figure 5 ChemStation Start button in the Instrument Control tab Agilent 1200 Infinity Series LC to Agilent 500 Ion Trap LC/MS Set-Up Guide 7

Step 3. Start the Sample List in MS Workstation and Sequence in ChemStation The Automated Liquid Sampler (ALS) prepares to inject the sample as specified by the ChemStation method. See Figure 6. Figure 6 ALS prepares to inject the sample 8 Agilent 1200 Infinity Series LC to Agilent 500 Ion Trap LC/MS Set-Up Guide

Step 3. Start the Sample List in MS Workstation and Sequence in ChemStation When the sample is injected, the LC method (specified by ChemStation) and the LC/MS method (specified by MS Workstation) is started. See Figure 7. Figure 7 Sample injection starts the ChemStation method and the MS Workstation LC/MS method Agilent 1200 Infinity Series LC to Agilent 500 Ion Trap LC/MS Set-Up Guide 9

Troubleshooting Troubleshooting If you have problems with the injection automation, please refer to this chart. 500 Ion Trap LC/MS: Troubleshooting ChemStation/MS Workstation Control Workflow MS Workstation does not wait for ChemStation MS Workstation data file is truncated Particular sample injections missing Too many MS data files generated Check 500-MS configuration in MS Workstation Check synchronization of runtimes Check synchronization of MS and LC Sample List/Sequence table Make sure 500-MS module is NOT in the AutoStart Module box in the configuration window LC runtime MS runtime #Vials/injections in MS sample list = #Vials/injections in LC sequence 10 Agilent 1200 Infinity Series LC to Agilent 500 Ion Trap LC/MS Set-Up Guide

Troubleshooting Agilent 1200 Infinity Series LC to Agilent 500 Ion Trap LC/MS Set-Up Guide 11

www.agilent.com In This Book This guide describes how to set up the Agilent 1200 Infinity Series to be used with the Agilent 500 Ion Trap LC/MS and the MS Workstation software. Agilent Technologies, Inc. 2010 Revision A0, November 2010 *930003220* 930003220 Agilent Technologies